midea vrf (v4+) mvrf.pdf · midea cac (mcac) as a key subsidiary of the midea group, the midea...

56
Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Upload: hoangkhanh

Post on 16-Feb-2019

260 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Midea VRF (V4+)

V4+S (Heat Pump)

V4+i (Individual) (Heat Pump)

V4+R (Heat Recovery)

MVR

F 05

/15

Page 2: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial solutions. Since 1999 MCAC has contributed to the R&D and innovation of technologically-based commercial solutions. Cooperation with leading global enterprises, coupled with independent R&D has enabled MCAC to implement thousands of commercial air-conditioning projects worldwide.

At present, MCAC is one of the leading product suppliers globally underpinned by a mature marketing, sales, and project design framework.

There are three production bases in Shunde, Chongqing and Hefei.MCAC Shunde: 38 product lines focusing on VRF (DC inverters and digital scroll products), split products, heat pump water heaters, and AHU/FCU.MCAC Chongqing: 14 product lines focusing on water cooled centrifugal/screw/scroll chillers, air cooled screw/scroll chillers, and AHU/FCU.MCAC Hefei: 11 product lines focusing on VRF, chillers, and heat pump water heaters.

2013 Launched the super high efficiency centrifugal chiller with full falling film technology2011 Launched the DC inverter V4 Plus globally2010 Built the 3rd manufacturing base in Hefei2007 Won the first Midea centrifugal chiller project overseas2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry2001 Partnered with Copeland to develop the digital scroll VRF system2000 Developed the first inverter VRF With Toshiba1999 Entered the CAC field

1999

2000

2004

2006

2007

2010

2011

2013

Year

2001

Page 3: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

V4+

S (H

eat P

ump)

V4+

i (H

eat P

ump)

V4+

R (H

eat R

ecov

ery)

Indo

or R

ange

04 V4+ S (Heat Pump)

14 V4+ i (Individual) (Heat Pump)

20 V4+ R (Heat Recovery)

27 Indoor Range

Content

Page 4: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

04

V4+ SHeat Pump

All InverterAll Inverter

Page 5: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• The above combination models are factory-recommended models.

ModelNo of

Outdoor Units

27

31.5

37.5

45

50

58.5

63

69

76.5

81.5

90

95

100

108

113

119

126.5

135

140

145

150

158.5

163

169

176.5

185

190

195

200

25.2

28

33.5

40

45

53.2

56

61.5

68

73

80

85

90

96

101

106.5

113

120

125

130

135

143.2

146

151.5

158

165

170

175

180

1

1

1

2

1

1

1

1

2

3

2

2

2

2

1

2

3

4

1

1

2

1

1

1

3

2

1

1

3

2

1

1

1

1

1

1

1

2

1

1

1

2

2

1

1

1

2

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

8HP

10HP

12HP

14HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

56HP

58HP

60HP

62HP

64HP

No of Compressors

Outdoor Unit Combination

8HP 10HP 12HP 14HP 16HP

Maximum No of Connectable

Indoor Units

Capacity (kW)

1

1

1

2

2

2

2

2

3

3

4

4

4

4

4

4

5

6

6

6

6

6

6

6

7

8

8

8

8

13

16

20

23

26

29

33

36

39

43

46

50

53

56

59

63

64

64

64

64

64

64

64

64

64

64

64

64

64

V4+ S (Heat Pump) - Recommended Combination Table

05

All InverterAll Inverter

Cooling Heating

V4+

S (H

eat P

ump)

Page 6: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

g

06

Notes:• Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.• Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.• *18HP can be customized.

MDV-252(8)W/D2RN1(B)M DV-280(10)W/D2RN1(B)M DV-335(12)W/D2RN1(B)

33.5

9.5

8.79

3.81

37.5

10.7

8.99

4.17

50-130

20

59

DC

2

13,000

560+380

2

31.59+11.80

27.6×4

FVC68D

500+500

R410A

12

4.4/2.6

1,250×1,615×765

1,305×1,790×820

288

308

28.0

8.0

7.05

3.97

31.5

9.0

7.55

4.17

50-130

16

25.2

7.2

5.88

4.29

27

7.7

6.15

4.39

50-130

13

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

mm

m3/h

W

Pa

Pa

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

-5~48

-20~24

57

DC

1

11,242

750

0-20 (default)

20-40 (customized)

1

31.59

27.6×2

FVC68D

500

R410A

10

4.4/2.6

960×1,615×765

1,025×1,790×830

212

227

0-20 (default)

20-60 (customized)

380-415/3/50

Heating

Connectible Indoor Unit

Pipe Connections

Fan Motor

DC Inverter Compressor

Refrigerant

Design Pressure (High/Low)

Net Dimension (WxHxD)

Packing Size (WxHxD)

Net/Gross Weight

Gross Weight

Cooling

Factory charging

Oil charge

Oil type

Quantity

ESP

Motor output

Outdoor air flow

Quantity

Type

Liquid pipe

Liquid pipe

Liquid pipe

COP

Power light

Capacity

EER

Power input

Capacity

Gas pipe

Oil balance pipe

Crankcase heater

Capacity

Heating

Operating Temperature Range

Sound pressure level

Cooling

Power Supply

Model

V4+ S (Heat Pump) - Outdoor Unit Specifications (Modular)

V4+

S (H

eat P

ump)

Page 7: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

07

Notes:• Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.• Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.• *18HP can be customized.

MDV-400(14)W/D2RN1(B)

MDV-450(16)W/D2RN1(B)

MDV-500(18)W/D2RN1(B)*

50.0

14.2

14.79

3.38

56.0

15.9

14.40

3.89

50-130

29

62

17

310

330

45.0

12.8

13.25

3.40

50.0

14.2

12.79

3.91

50-130

26

62

DC

2

15,620

560+380

2

31.59+11.80

27.64

FVC68D

500+500

R410A

15

288

308

40.0

11.4

11.30

3.54

45.0

12.8

11.19

4.02

50-130

23

61

15

288

308

-5~48

-20~24

0-20 (default)

20-40 (customized)

4.4/2.6

380-415/3/50

V4+S (Heat Pump) – Outdoor Unit Specifications (Modular)

All InverterAll Inverter

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

mm

m3/h

W

Pa

Pa

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

Heating

Connectible Indoor Unit

Pipe Connections

Fan Motor

DC Inverter Compressor

Refrigerant

Design Pressure (High/Low)

Net Dimension (WxHxD) 1250 x 1615 x 765

1305 x 1790 x 820Packing Size (WxHxD)

Net/Gross Weight

Gross Weight

Cooling

Factory charging

Oil charge

Oil type

Quantity

ESP

Motor output

Outdoor air flow

Quantity

Type

Liquid pipe

Liquid pipe

Liquid pipe

COP

Power light

Capacity

EER

Power input

Capacity

Gas pipe

Oil balance pipe

Crankcase heater

Capacity

Heating

Operating Temperature Range

Sound pressure level

Cooling

Power Supply

Model

V4+

S (H

eat P

ump)

Page 8: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

08

8/10 HP

1615

765

960

12/14/16 /18 HP

1250

1615

765

Unit: mm

Body dimensions

Installation dimensions

V4+ S (Heat Pump) - Outdoor Unit Dimensions

V4+

S (H

eat P

ump)

Page 9: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

09

8, 10HP 12, 14, 16HP 20, 22, 24, 26, 28, 30, 32, 34, 36H18HP

56, 58, 60, 62, 64, 66, 68, 70, 72HP38, 40, 42, 44, 46, 48, 50, 52, 54HP

8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40-72HP

5

10

15

20

25

30

35

40

45

50

55

60

65

13

1620

2326

2933

3639

4346

5053

5659

63 64

• The outdoor capacity ranges from: 8Hp - 72Hp in increments of 2Hp.• A maximum of 64 indoor units can be connected to one refrigerant system, up to 130% of the outdoor capacity.

* Outdoor unit capacity range = 8HP, 72HP in 2HP increments. A maximum of 64 indoor units can be connected to one refrigerant system, up to 130% of outdoor capacity.

Wide range of outdoor units

Combination Table: Indoor / Outdoor

V4+ S (Heat Pump) - Features

All InverterAll Inverter

V4+

S (H

eat P

ump)

Page 10: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

10

Outdoor Temperature

01 02 03 04 0 50-1 0-2 0

COOLING MODE

HEATING MODE*

Outdoor temperature (DB)

48 C

24 C-20 C

-5 C Outdoor Temperature

Wide operation range

Long Pipe Lengths

Stable performance at extreme conditions, ranging from : -2°C → 48°C .

Permitted value (m)

Actual total piping length

Longest piping

Outdoor unit down

Outdoor unit up

Equivalent length

Actual length

1000*

175

200

40/90*

70

110

30

Level difference between indoor and outdoor units

Level difference between indoor units

Piping length

Level difference

* If exceeding 40m (First Branch – Last Indoor), Installation parameters must be adhered to per the installation manual.

Equivalent pipe length from first branch joint to furthest indoor unit

V4+ S (Heat Pump) - Features90

m

Leve

l diff

eren

ce b

etw

een

IDU

_OD

U is

110

m

Max

imum

pip

ing

actu

al le

ngth

175

m

Leve

l diff

eren

ce b

etw

een

IDU

_OD

U is

30m

V4+

S (H

eat P

ump)

Page 11: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

All DC Inverter Compressors

All DC Fan Motors

Mot

or s

peed

(RP

M)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

EER COP

8HP1 0HP1 2HP1 4HP 16HP 18HP

4.39 4.17 4.17 4.02 3.91 3.89

8HP1 0HP1 2HP1 4HP1 6HP1 8HP

4.293.97 3.81 3.54 3.4 3.38

High COP/EER values

All DC inverter technology

EER = 4.29 COP = 4.39 >8HP

All DC Inverter Compressor Ensures:• Improved output capacity.• Efficient operating range (60 – 140Hz).

New structure enhances mid-frequency performance

Specially designed scroll profile for R410A

More compact, weight reduced by 50%

Advanced permanent magnet DC motor improvesthe low frequency band performance

• Fan speed is determined by actual load requirements, ensuring minimal energy consumption.

11

V4+ S (Heat Pump) - Features

All InverterAll Inverter

V4+

S (H

eat P

ump)

Page 12: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

00

0.20 .4 0.60 .8 1

0.2

0.4

0.6

0.8

New design

Original design

Frost contrast

Relative frosting rateR

elat

ive

win

dage

resi

stan

ce

Reduce 28%

Reduce 30%

00

200 400 600 800 1000 Re

0.2

0.4

0.6

0.8

New design

Original design

Rel

ativ

e w

inda

ge re

sist

ance

New design Original design

High efficiency inner-threaded pipe, enhance heat transfer.

Reduce air resistance.

Hydrophilic film fins + inner-threaded pipes

Gas

Gas

Gas

Liquid

Liquid

Liquid

Gas LiquidGas-Liquid

Increase the hot liquid rate in the condenserImprove the heat-exchange efficiency

Original design

New design

Common Design

Sub-cooling Technology

High performance heat exchanger

Improved designed window fins: enlarges the heat-exchanging area, decreases the air resistance, saves more power and enhances heat exchange performance.

Innovative designed high efficiency heat exchanger, which can reach up to 12°C sub-cooling, reduces the system resistance and improves reliability.

Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.

12

V4+ S (Heat Pump) - Features

Windage & air flow

V4+

S (H

eat P

ump)

Page 13: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

.

Hea

ting

capa

city

Usual defrosting

Time

t min

Intelligent defrosting

Night time silent operation

Intelligent defrosting technology

Simple signal line connection

Auto addressing

• Outdoor unit “Silent Mode” = Super Quite Operation. Min Level = 45dB(A)

Night silent operation will beactivated X hours after the peaktemperature during daytime,and it will go back to normaloperation after Y hours.

• Defrosting time is determined by actual requirements.• Improved duration = Improved Performance.

• Centralized controller (CCM03 or CCM30) can be connected from Indoor or Outdoor side. (X Y E Terminals).• One Group Communication Line (P Q E) to control Indoor and Outdoor.

Outdoor unit can distribute addresses for indoorunit automatically.

Wireless and wired controllers can query andmodify each indoor unit’s address.

13

V4+ S (Heat Pump) - Features

Y YXX QPE E E

Q Q Q QP P P PE E E E

All InverterAll Inverter

V4+

S (H

eat P

ump)

Page 14: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

V4+ iHeat Pump

14

Page 15: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

15

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

V4+ i (Heat Pump) - Outdoor Unit Specifications - Horizontal Discharge

MDV-V200W/DRN1 MDV-V224W/DRN1 MDV-V260W/DRN1 MDV-V400W/DRN1 MDV-V450W/DRN1Model

20.0

5.7

6.1

3.28

22.0

6.3

6.1

3.61

50-130

10

59

10,999

210+160

1

13.98

25

FV50S

1400

R410A

4.8

137

153

22.4

6.4

6.8

3.29

24.5

7

5.9

4.15

50-130

11

59

146.5

162.5

26.0

7.4

7.6

3.42

28.5

8.1

6.8

4.19

50-130

12

60

10,494

200+150

1

16.86

25

FV50S

1700

R410A

6.2

147

163

Power supply

Cooling

Heating

Connectable indoor unit

Sound pressure level

Pipe connections

Fan motor

Rotary compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

m3/h

W

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

Operatingtemperature range

-15~46

-15~24

1,120×1,558×528

1,270×1,720×565

DC

2

10,494

200+150

1

16.86

25

FV50S

1700

R410A

6.2

380-415/3/50

40.0

11.4

11.9

3.35

45.0

12.8

11.1

4.05

50-130

14

62

16 575

560+320

2

13.98×2

25×2

FV50S

1400×2

R410A

9

1360×1650×540

1450×1785×560

240

260

45.0

12.8

13.6

3.32

50.0

14.2

12.7

3.93

50-130

15

62

16,575

560+320

2

16.86×2

25×2

FV50S

1700×2

R410A

12

1460×1650×540

1550×1785×560

275

290

DC+AC

2

4.4/2.6

-5~48

-15~24

V4+

i (H

eat P

ump)

Page 16: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

16

V4+i (Heat Pump) – Outdoor Unit Specifications (Individual)

V4+

i (H

eat P

ump)

Power supply

Cooling

Heating

Sound pressure level

Pipe connections

Fan motor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantiy

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

m3/h

W

Pa

Pa

kW

W

ml

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

Connectableindoor unit

DC inverter compressor

Fixed inverter scroll compressor

Operatingtemperature range

MDV-252W/DRN1-i(B)

MDV-280W/DRN1-i(B)

MDV-335W/DRN1-i(B)

MDV-400W/DRN1-i(B)

MDV-450W/DRN1-i(B)

Model

380-415/3/50

0~20 (default)

20~40 (customized)

-5~48

-15~24

4.4/2.6

DC

1

11,000

560

1

31.59

27.6×2

FVC68D

500

/

/

/

/

/

R410A

10

960×1,615×765

1,025×1,790×830

205

220

DC

2

15,000

450×2

1

11.8

27.6×2

FVC68D

500

R410A

1,250×1,615×765

1,305×1,790×820

25.2

7.2

5.9

4.29

27.0

7.7

6.2

4.39

50-130

13

57

28.0

8.0

7.2

3.89

31.5

9.0

7.6

4.14

50-130

16

57

33.5

9.5

9.1

3.70

37.5

10.7

9.0

4.17

50-130

16

58

1

17.1

27.6

FVC68D

500

R410A

12

275

295

40.0

11.4

12.3

3.25

45.0

12.8

11.2

4.02

50-130

16

60

2

15.39

27.6×2

FVC68D

500×2

15

325

345

45.0

12.8

14.0

3.21

50.0

14.2

12.8

3.91

50-130

20

60

2

17.1

27.6×2

FVC68D

500×2

R410A

15

325

345

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27oC DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20oC DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter. • Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

Page 17: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

56.0

15.9

17.0

3.30

63.0

17.9

16.0

3.94

50-130

33

62

20,000

340+450

2

15.39×2

33×2

FVC68D

500×2

R410A

17

1,390×1,615×765

1,455×1,790×830

360

375

61.5

17.5

18.8

3.27

69.0

19.6

17.9

3.86

50-130

36

63

23,000

625+450

2

17.1×2

33×2

FVC68D

500×2

R410A

18.5

385

400

67.0

19.0

20.8

3.22

75.0

21.3

19.8

3.79

50-130

39

63

23,000

625+450

2

20.9×2

33×2

FVC68D

1100×2

R410A

18.5

390

405

Power supply

Cooling

Heating

Sound pressure level

Pipe connections

Fan motor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantiy

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

m3/h

W

Pa

Pa

kW

W

ml

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

Connectableindoor unit

DC inverter compressor

Fixed inverter scroll compressor

Operatingtemperature range

MDV-560W/DRN1-i(C) MDV-615W/DRN1-i(C) MDV-670W/DRN1-i(C)Model

380-415/3/50

0~20 (default)

20~40 (customized)

1

31.59

30×2

FVC68D

500

DC+AC

2

-5~48

-15~24

1,585×1,615×765

1,650×1,810×840

4.4/2.6

17

V4+i (Heat Pump) – Outdoor Unit Specifications (Individual)

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.• Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

V4+

i (H

eat P

ump)

Page 18: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Power supply

Cooling

Heating

Sound pressure level

Pipe connections

Fan motor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantiy

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kW

kW/kW

kW

RT

kW

kW/kW

%

dB(A)

mm

mm

m3/h

W

Pa

Pa

kW

W

ml

kW

W

ml

kg

MPa

mm

mm

kg

kg

°C

°C

Connectableindoor unit

DC inverter compressor

Fixed inverter scroll compressor

Operatingtemperature range

MDV-850W/DRN1-i(C)MDV-785W/DRN1-i(C) )C(i-1NRD/W009-VDM)C(i-1NRD/W037-VDMModel

380-415/3/50

0~20 (default)

20~40 (customized)

1

31.59

30×2

FVC68D

500

-5~48

-15~24

73.0

20.7

22.3

3.27

81.5

23.1

20.6

3.96

50-130

43

64

3

17.1×3

30×2+33

FVC68D

500×3

555

590

78.5

22.3

24.2

3.24

87.5

24.9

22.4

3.91

50-130

46

64

3

17.1×3

30×2+33

FVC68D

500×3

555

590

85

24.1

28.3

3.00

95.0

27.0

26.0

3.65

50-130

50

65

4

17.1×4

27.6×2+33+30

FVC68D

500×4

600

635

90

25.6

28.5

3.16

100.0

28.4

26.5

3.77

50-130

53

65

4

17.1×4

27.6×2+33+30

FVC68D

500×4

600

635

R410A

27

4.4/2.6

2,540×1,615×765

2,600×1,800×825

AC

4

27,900

520×2+380×2

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.• Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

18

V4+ i (Heat Pump) - Outdoor Unit Specifications (Individual)

V4+

i (H

eat P

ump)

Page 19: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

19

668 205.8

414

400

528

494

1558

1120

1615

2540 765

800

73/78.5/85/90kW

1615

765

1390

56kW

1615

765

1585

61.5/67kW

40/45kW20/22.4/26kW

1650

C

540

500

505

475

450

AB

225

175

555

505

1460

136040kW

AB C

45kW

ModelSize

V4+ i (Heat Pump) - Outdoor Unit Dimensions

V4+

i (H

eat P

ump)

Page 20: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

V4+RHeat Recovery

20

Page 21: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.• *Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

RefrigerantR410A

13

Type

Factory charging kg

Design pressure (High/Low) 4.4/2.6MPa

Net dimension (WxHxD) 1250x1615x765mm

Packing size (WxHxD) 1305x1790x820mm

Net weight 303kg

Gross weight 322kg

Operatingtemperaturerange

-5-48°C

-20-24°C

Cooling

Heating

Model MDV-450(16)W/D2RN1(C)

V/Ph/HzPower supply 380-415/3/50

kW

Cooling

45.0

RT 12.8

kW 13.24

kW/kW 3.40

Capacity

Input

EER

kW

Heating

50.0

RT 14.2

kW 12.79

kW/kW 3.91

Capacity

Input

COP

%Connectibleindoor unit 26

Total capacity

Max. quantity

50-130

dB(A)Sound pressure level 60

mm

Pipeconnections

Φ15.9

mm Φ28.6

mm Φ22.2

Liquid pipe

Low pressure gas pipe

High pressure gas pipe

Fan motor

DC

2

m3/h 15,000

Type

Quantity

Air flow rate

W 750

Pa 0~20 (default)

Pa 20~40 (customized)

Motor output

ESP

DC invertercompressor

1

31.59 + 11.8

W 30x4

Quantity

Capacity

Crankcase heater

FVC68D

ml

Oil type

kW

500+ 500Oil change

mm Φ22.2High pressure gas balance pipe

R410A

10

4.4/2.6

1250x1615x765

1305x1790x820

255

273

MDV-252(8)W/D2RN1(C)

380-415/3/50

25.2

7.2

5.73

4.40

27.0

7.7

6.00

4.50

50-130

13

57

Φ9.53

Φ22.2

Φ19.1

DC

2

12,000

420

0~20 (default)

20~60 (customized)

1

31.59

30x2

FVC68D

500

Φ19.1

Φ6mm

R410A

10

4.4/2.6

1250x1615x765

1305x1790x820

255

273

MDV-280(10)W/D2RN1(C)

380-415/3/50

28.0

8.0

6.67

4.20

31.5

8.9

7.33

4.30

16

50-130

57

Φ12.7

Φ22.2

Φ19.1

DC

2

12,000

420

0~20 (default)

20~60 (customized)

1

31.59

30x2

FVC68D

500

Φ19.1

Φ6

R410A

10

4.4/2.6

1250x1615x765

1305x1790x820

255

273

MDV-335(12)W/D2RN1(C)

380-415/3/50

33.5

9.5

8.07

4.15

37.5

10.7

8.72

4.30

20

50-130

58

Φ12.7

Φ25.4

Φ19.1

DC

2

13,000

420

0~20 (default)

20~60 (customized)

1

31.59

30x2

FVC68D

500

Φ19.1

Φ6

R410A

13

4.4/2.6

1250x1615x765

1305x1790x820

303

322

MDV-400(14)W/D2RN1(C)

380-415/3/50

40.0

11.4

11.30

3.54

45.0

12.8

11.19

4.02

23

50-130

60

Φ15.9

Φ28.6

Φ22.2

DC

2

15,000

750

0~20 (default)

20~40 (customized)

1

31.59 + 11.8

30x4

FVC68D

500+ 500

Φ22.2

Φ6 Φ6Oil balance pipe

°CSimultaneousCooling and Heating

-5~24

21

V4+R (Heat Recovery) – Outdoor Unit Specifications (Modular)

V4+

R (H

eat R

ecov

ery)

Page 22: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Notes:Capacities are based on the following conditions:• Cooling: Indoor temperature 27°C DB/19°C WB; Outdoor temperature 35°C DB/24°C WB.• Heating: Indoor temperature 20°C DB/15°C WB; Outdoor temperature 7°C DB/6°C WB.• Piping length: Interconnecting piping length is 7.5m, level difference is zero.• The above combination models are factory-recommended models.

ModelNo of

Outdoor Units

27

31.5

37.5

45

50

58.5

63

69

76.5

81.5

90

95

100

108

113

119

126.5

135

140

145

150

158.5

163

169

176.5

185

190

195

200

25.2

28

33.5

40

45

53.2

56

61.5

68

73

80

85

90

96

101

106.5

113

120

125

130

135

143.2

146

151.5

158

165

170

175

180

1

1

1

2

1

1

1

1

2

3

2

2

2

2

1

2

3

4

1

1

2

1

1

1

3

2

1

1

3

2

1

1

1

1

1

1

1

2

1

1

1

2

2

1

1

1

2

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

8HP

10HP

12HP

14HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

56HP

58HP

60HP

62HP

64HP

No of Compressors

Outdoor Unit Combination

8HP 10HP 12HP 14HP 16HP

Maximum No of Connectable

Indoor Units

Capacity (kW)

1

1

1

2

2

2

2

2

3

3

4

4

4

4

4

4

5

6

6

6

6

6

6

6

7

8

8

8

8

13

16

20

23

26

29

33

36

39

43

46

50

53

56

59

63

64

64

64

64

64

64

64

64

64

64

64

64

64

22

Cooling Heating

V4+R (Heat Recovery) – Recommended Combination Table

V4+R

(Hea

t Rec

over

y)

Page 23: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

MS units which can be connected to multiple indoor unitsMode MS01/N1-C MS02/N1-C MS04/N1-C MS06/N1-C

Max. indoor unit groups 1 2 4 6

Max. number of each group indoor units 4 4 4 4

Max. number of all downstream indoor units 4×1=4 4×2=8 4×4=16 4×6=24

Max. capacity of each group indoor units16

54.6

Total capacity of all downstream indoor units ≤16 ≤28 ≤45

≤153.5

Piping connections

Connect to outdoor unit

Liquid pipe In.(mm) Φ3/8(9.53) Φ1/2(12.7) Φ5/8(15.9)

High pressure gas pipe In.(mm) Φ5/8(15.9) Φ3/4(19.1) Φ7/8(22.2)

Low pressure gas pipe In.(mm) Φ3/4(19.1) Φ1(25.4) Φ1-1/4(31.8)

Connect to indoor unitLiquid pipe In.(mm) Φ3/8(9.53)

Gas pipe In.(mm) Φ5/8(15.9)

Sound pressure level dB(A) 33 33 33 40

Net dimension (W×H×D) inch 24-3/4×8-7/8×23-5/8 37-13/16×8-7/8×23-5/8

mm 630×225×600 960×225×600

Packing size (W×H×D) inch 28-9/16×12-3/4×27 41-1/2×12-3/4×27

mm 725×325×685 1055×325×685

Net weight Ibs.(kg) 39.6(18) 42.9(19.5) 68.2(31) 77(35)

Gross weight Ibs.(kg) 55(25) 59.4(27) 88(40) 97.9(44.5)

MS units which can be connected to only one indoor unitMode MS02E/N1-C MS04E/N1-C

Max. number of all downstream indoor units 1 1

Capacity of indoor unit kW 20~28 40~56

kBtu/h 68.2~95.5 136.5~191.1

Piping connections

Connect to outdoor unit

Liquid pipe In.(mm) Φ1/2(12.7) Φ5/8(15.9)

High pressure gas pipe In.(mm) Φ3/4(19.1) Φ7/8(22.2)

Low pressure gas pipe In.(mm) Φ1(25.4) Φ1-1/4(31.8)

Connect to indoor unitLiquid pipe In.(mm) Φ3/8(9.53) Φ3/8(9.53)

Gas pipe In.(mm) Φ5/8(15.9) Φ5/8(15.9)

Sound pressure level dB(A) 33 33

Net dimension (W×H×D) inch 24-3/4×8-

7/8×23-5/837-13/16×8-7/8×23-5/8

mm 630×225×600 960×225×600

Packing size (W×H×D) inch 28-9/16×12-3/4×27 41-1/2×12-3/4×27

mm 725×325×685 1055×325×685

Net weight Ibs.(kg) 42.9(19.5) 68.2(31)

Gross weight Ibs.(kg) 59.4(27) 88(40)

Note:• Sound values are measured in a semi-anechoic room, at a position 1m below the MS equipment in mode switch condition.• It is not recommended to install in the place where high noise performance is required.

kW

kBtu/h

kBtu/h

≤95.5≤54.6

kW

23

V4+R (Heat Recovery) – MS Specifications

V4+

R (H

eat R

ecov

ery)

Page 24: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

24

• A typical heat recovery system consists of outdoor units, MS mode switch box and indoor units, as well as the copper pipe and branch pipes.• A heat recovery system offers high energy-saving efficiency by drawing heat from the rooms to be cooled, and effectively using it as a heat source for the rooms to be heated

The high static fan design and plenum accessory can be adapted where application is required.

Midea now offers up to 60Pa* external static pressure units for customized applications (60Pa is available for the 12HP model, 40Pa is available for other models). A standard 0-20Pa function is equipped by default.

Multiple Systems: Should Master unit fail, any remaining unit can be set as Master, enabling operation of remaining units.

Heat Recovery Operation - Significantly Enhancing Energy Efficiency

Extra high static pressure Max. 60Pa, air volume increased by 10%

Back-up Function

Heat Absorption

Heat Release

Heat Release

Internal Transfer Internal Transfer

* When the slave 1 failed and came into standby state, the left module can still work.

*

Master Slave 1 Slave 2

Notes:• Total pipe length is equal to two times pipe length plus pipe length.• When the piping length from the farthest IDU to the first indoor branch joint is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual to achieve 90m.

90m

Leve

l diff

eren

ce b

etw

een

IDU

_OD

U is

110

m

Max

imum

pip

ing

actu

al le

ngth

175

m

Leve

l diff

eren

ce b

etw

een

IDU

_OD

U is

30m

Permitted value (m)

Actual total piping length

Longest piping Piping length

Level difference

Equivalent piping length from the farthest IDU to the first indoor branch joint

Equivalent piping length from MS to its downstream indoor unit

Outdoor unit up

Outdoor unit down

Actual length

Equivalent length

1000*

175

200

40/90*

40

70

110

30

Level difference between indoor and outdoor units

Level difference between indoor units

V4+R (Heat Recovery) – Key Features

V4+R

(Hea

t Rec

over

y)

Page 25: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

2512 ty

pes

and

mor

e th

an 1

00 m

odel

s ar

e av

aila

ble

to m

eet v

arie

d cu

stom

er re

quire

men

ts,1

.5kW

mod

el is

onl

y av

aila

ble

for V

4 pl

us a

nd M

INI V

RF

syst

em.

Type

One

-way

Cas

sette

MD

V-D

XX

Q1/

N1-

D

MD

V-D

XX

Q1/

N1-

C

MD

V-D

XX

Q2/

N1

MD

V-D

XX

Q4/

N1-

A3

MD

V-D

XX

Q4/

N1-

D

MD

V-D

XX

T3/

N1-

C

MD

V-D

XX

T2

/N1-

BA

5

MD

V-D

XX

T2

/N1-

DA

5

MD

V-D

XX

T1/

N1-

B

MD

V-D

XX

DL/

N1-

C

MD

V-D

XX

G/N

1-S

MD

V-D

XX

G/N

1YB

MD

V-D

XX

G/D

N1-

S

MD

V-D

XX

G/D

N1Y

B

MD

V-D

XX

G-R

3/N

1Y

MD

V-D

XX

G

/N1Y

-11D

5

MD

V-D

XX

Z/

N1-

F3B

MD

V-D

XX

Z/D

N1-

B

MD

V-D

XX

T1/

N1-

FA

MD

V-D

XX

Z/

N1-

F4(F

5)

Two-

way

Cas

sette

Com

pact

Fou

r-w

ay

Cas

sette

Four

-way

Cas

sette

Low

sta

tic p

ress

ure

duct

Con

ceal

ed d

uct u

nit

(A5

Type

)

Hig

h S

tatic

P

ress

ure

Duc

t

Cei

ling

and

Floo

r

Wal

l-mou

nted

Floo

r Sta

ndin

g

Con

sole

Fres

h A

ir P

roce

ssin

g U

nit

Mod

el15

2218

2836

4556

7180

9010

011

212

514

016

020

020

025

028

040

045

056

0kW

1.5

2.2

1.8

2.8

3.6

4.5

5.6

7.1

8.0

9.0

10.0

11.2

12.5

14.0

16.0

20.0

20.0

25.0

28.0

40.0

45.0

56.0

V4+ Indoor Table

Page 26: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Midea VRF (V4+)

Page 27: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

V4+Indoor Range

27

Page 28: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

28

Auto Restart Fresh Air

Auto Addressing Cleanable Panel

Follow Me Anti-Cold Air Function

LED Display Built-in Drain PumpLEDDisplay

Only 153mm thickness

Fresh Air

Auto Swing

Compact design,ultra slim body with a minimum thickness of 153mm for model 18-36,especially suitable for narrow ceiling , such as in lobbies and small meeting rooms.

Standard built-in drain pump with 750mm pump head.

Reserved fresh air intake port for high quality air creates a comfortable and healthy environment.

Special enzyme sterilization and filtering technologies filter bacteria, smog, and pollen. Provide a clean, healthy and natural air supply.

Auto swing mechanism guarantees even airflow distribution and a better room temperature balance.

One-way Cassette

Indo

or R

ange

Page 29: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

29

Notes:Nominal cooling capacities are based on the following conditions: • Return air temperature: 27°C DB,19°C WB,outdoor temperature:35°C DB, equivalent ref. Piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: • Return air temperature: 20°C DB,outdoor temperature: 7°C DB, 6°C WB,equivalent ref. Piping: 8m (horizontal)• Sound level is measured at 1.4m below the unit.

One-way Cassette - Specifications

ModelMDV-D18Q1

/N1-DMDV-D22Q1

/N1-DMDV-D28Q1

/N1-DMDV-D36Q1

/N1-DMDV-D45Q1

/N1-CMDV-D56Q1

/N1-C

OD Ф25

OD Ф12.7 OD Ф12.7 OD Ф12.7 OD Ф15.9

OD Ф6.35 OD Ф9.53OD Ф6.35OD Ф6.35

3.5/5.2

1232×107×517

1180×36.5×465

12.5/16

37/34/30

308/238/162

523/404/275

0.24

0.24

41

41

7500

1900

2.2

6100

1500

1.8

38/34/30

308/238/162

523/404/275

0.24

0.24

41

41

8900

2200

2.6

7500

1900

2.2

39/37/34

337/268/185

573/456/315

0.25

0.25

41

41

10900

2800

3.2

9600

2400

2.8

1-phase,220-240V,50Hz

40/38/34

337/268/185

573/456/315

0.25

0.25

41

41

13600

3400

4

12300

3100

3.6

41/39/35

414/370/296

704/630/503

0.37

0.37

80

80

17100

4300

5

15400

3900

4.5

42/40/36

506/476/413

860/810/702

0.39

0.39

85

85

21500

5400

6.3

19100

4800

5.6

3.5/5.2

1232×107×517

1180×36.5×465

13/16.5

EXV

R410A

1155×245×490

1054×169×425

9/12

1500×110×870

1425×10×755

31.5/37.2

1380×265×775

1147×200×640

OD Ф25 OD Ф25

Wireless remote controller RM05/BG(T)E-A/E)

Power supply

Cooling capacity

Heating capacity

Rated input

Rated current

Heating

Heating

Cooling

Cooling

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant

Body

Panel

Drain piping mm

mm

mm

mm

mm

A

W

Btu/h

Btu/h

kcal/h

kcal/h

kW

kW

Type

dB(A)

CFM

m /h3

Control method

kg

kg

G(flare)

L(flare)

Net/gross

Net/gross

Gross dim.(WxHxD)

Gross dim.(WxHxD)

Net dim.(WxHxD)

Net dim.(WxHxD)

Standard controller

Piping connections G (flare)

Indo

or R

ange

Page 30: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

30

Auto Restart Fresh Air

Auto Addressing Cleanable Panel

Follow Me Anti-Cold Air Function

LED Display Built-in Drain PumpLEDDisplay

Quiet operation

Stylish design and slim body

High air flow

Optimized Airflow duct with low resistance significantly reduces noise.

Thanks to the stylish appearance and slim body, the unit suits any room’s decor and ambiance. At only 300mm high, the unit requires only a small suspended ceiling space. Installation has no height limitations, which makes overall design features much more flexible.

Standard built-in drain pump with 750mm pump head (higher pump head can be customized).

Flat-type suction grille design greatly simplifies maintenance work.

High air flow ensures even distribution and air flow in large volume area’s.

Two-way Cassette

Indo

or R

ange

Page 31: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

31

Notes:• Nominal cooling capacities are based on the following conditions: return air temperature : 27°C DB,19°C WB,outdoor temperature.:35°C DB, equivalent ref. Piping: 8m (horizontal)• Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB,outdoor temperature.: 7°C DB, 6°C WB,equivalent ref. Piping: 8m (horizontal)• Sound level is measured at 1.4m below the unit.

One-way Cassette - Specifications

Power supply 1-phase, 220-240V, 50Hz

Model

Cooling capacity

Heating capacity

Rated input

Rated currentHeating

Heating

Cooling

Cooling

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant

Body

Panel

Drain piping mm

Wireless remote controller(RM05/BG(T)E-A)

mm

mm

mm

mm

A

W

Btu/h

Btu/h

kcal/h

kcal/h

kW

kW

MDV-D22Q2/N1

2.2 2.8 3.6 4.5 5.6 7.1

2.6 3.2 4.0 5.0 6.3 8.0

2,200

8,900

57

57 57

57

10,900

9,600

2,400

2,800

60

60

13,600

12,300

3,100

3,400

92

92

17,100

15,400

3,900

4,300

108

108

21,500

19,100

4,800

5,400

154

154

27,300

24,200

6,100

6,900

0.35

0.35 0.45

0.45

0.45

0.45

0.55

0.55

0.55

0.55

0.75

0.75

654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1,200/1,000/770

385/312/241 385/312/241 427/348/270 500/394/324 577/471/394 706/589/453

33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34

1,172×299×591 1,172×299×591 1,172×299×5911,172×299×591 1,172×299×591 1,172×299×591

1,355×400×675 1,355×400×675 1,355×400×6751,355×400×675 1,355×400×675 1,355×400×675

34/42.5 34/42.5 34/42.5 36/44.5 36/44.5 36/44.5

1,430×53×680 1,430×53×680 1,430×53×6801,430×53×680 1,430×53×680 1,430×53×680

1,525×130×765 1,525×130×765 1,525×130×7651,525×130×765 1,525×130×765 1,525×130×765

10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15

Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53

Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9

ODΦ32 ODΦ32 ODΦ32 ODΦ32 ODΦ32 ODΦ32

R410A

EXV

1,900

7,500

MDV-D28Q2/N1 MDV-D36Q2/N1 MDV-D45Q2/N1 MDV-D56Q2/N1 MDV-D71Q2/N1

Type

dB(A)

CFM

m /h3

Control method

kg

kg

G(flare)

L(flare)

Net/gross

Net/gross

Gross dim.(WxHxD)

Gross dim.(WxHxD)

Net dim.(WxHxD)

Net dim.(WxHxD)

Standard controller

Piping connections G (flare)

Indo

or R

ange

Page 32: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

32

Auto Restart Fresh Air

Auto Addressing Cleanable Panel

Follow Me Anti-Cold Air Function

LED Display

Super High Air Flow

Built-in Drain PumpLEDDisplay

Compact design, easy installation and maintenance

Compact design allows easy installation is space restricted area’s.

Quiet operation, gentle air supply

360°Airflow outlet

Four-way uniform airflow

Lift pump

Streamline plate ensures quiet operationAdvanced 3-D spiral fan design reduces airresistance and operation noise.

360° air outlet provides strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature.

Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature. High airflow mode can maximize the conditioning effect in rooms that are over 3m high.

Drain pump with a 500mm pumphead is fitted asstandard; maximum 600mm pumphead is available.

3-D spiral fan blade

Diffuser

Compact Four-way Cassette

Indo

or R

ange

Page 33: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Notes:• Nominal cooling capacities are based on the following conditions: return air temperature : 27°C DB,19°C WB,outdoor temperature.:35°C DB, equivalent ref. Piping: 8m(horizontal) • Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB,outdoor temperature.: 7°C DB, 6°C WB, equivalent ref. Piping: 8m(horizontal)• Sound level is measured at 1.4m below the unit.

R410A

EXV

1-phase,220-240V,50Hz

1.5

1.7

1300

36

0.22

0.22

0.22

5100

36

0.22

2.4/4.5

715x123x715

647x50x647

675x285x675

570x260x570

34.9/32.5/22.5

295/256/167/98

501/435/283/208

16/19.5

2.4/4.5

715x123x715

647x50x647

675x285x675

570x260x570

35.8/33.4/23.4

307/244/184/140

522/414/313/238

16/20

2.4/4.5

715x123x715

647x50x647

675x285x675

570x260x570

35.8/33.4/23.4

307/244/184/140

522/414/313/238

16/20

2.4/4.5

715x123x715

647x50x647

675x285x675

570x260x570

41.5/35.6/28.8

359/307/241/185

610/521/409/314

18/22

2.4/4.5

715x123x715

647x50x647

675x285x675

570x260x570

41.5/35.6/28.8

359/307/241/185

610/521/409/314

18/22

2.2

2.4

1900

50

0.22

0.22

0.22

7500

50

0.22

2.8

3.2

2400

50

0.22

0.22

0.22

9600

50

0.22

3.6

4

3100

56

0.25

0.25

0.25

12300

56

0.25

4.5

5

3900

56

0.25

0.25

0.25

15400

56

0.25

Wireless remote controller (RM05/BG(T)E-A)

MDV-D15Q4/N1-A3

MDV-D22Q4/N1-A3

MDV-D28Q4/N1-A3

MDV-D36Q4/N1-A3

MDV-D45Q4/N1-A3

33

Compact Four-way Cassette - Specifications

Power supply

Model

Cooling capacity

Heating capacity

Rated input

Rated currentHeating

Heating

Cooling

Cooling

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant

Body

Panel

Drain piping mm OD Ф25

Ф12.7

Ф6.35

OD Ф25

Ф12.7

Ф6.35

OD Ф25

Ф12.7

Ф6.35

OD Ф25

Ф12.7

Ф6.35

OD Ф25

Ф12.7

Ф6.35

mm

mm

mm

mm

A

W

Btu/h

Btu/h

kcal/h

kcal/h

kW

kW

Type

dB(A)

CFM

m /h3

Control method

kg

kg

G(flare)

L(flare)

Net/gross

Net/gross

Gross dim.(WxHxD)

Gross dim.(WxHxD)

Net dim.(WxHxD)

Net dim.(WxHxD)

Standard controller

Piping connections G (flare)

Indo

or R

ange

Page 34: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

34

Auto Restart Fresh Air

Auto Addressing Cleanable Panel

Follow Me Anti-Cold Air Function

LED Display

Super High Air Flow

Built-in Drain PumpLEDDisplay

High lift pump

Drain pump can take condenser water up to 750mm, which simplifies installation of the drain piping system.

Ultra-thin machine body (minimum height 230mm) simplifies installation and maintenance.

Quiet operation, gentle air supply

Easy troubleshooting

Four-way uniform airflow

360°Airflow outlet

Streamline plate ensures quiet operationAdvanced 3-D spiral fan design reduces airresistance and operation noise.

3-D spiral fan blade

Diffuser

By adding digital tube on the display board, Error Codes can be displayed directly for troubleshooting.

Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and evenly distrib-ute temperature. High airflow mode can maximize the conditioning effect in rooms that are over 3m high.

360° air outlet provides strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature.

Four-way Cassette

Indo

or R

ange

Page 35: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

35

Low sound level

Auto Addressing

Follow Me

Anti-Cold Air Function

Super High Air Flow Wireless remote controller

Auto Restart

V shape evaporator-- good for heat exchanging

Compact design

Convenient for installation and maintenance

Options

V shape evaporator design enhances heat exchanging efficiency about 22%.

Uniform 210mm in height, compact design for easy locate where space ceiling is limited. The whole body adopts fireproof plastic material, the minimum weight is 14kg.

The EXV is fixed inside the indoor unit.

A drain pump with 750mm pumphead is an optional accessory.

Utilizes the centrifugal type blower, provides a minimum noise level of 24dB (A), an excellent choice for hotels and other sound-sensitive places.

Low Static Pressure Duct

Indo

or R

ange

Page 36: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Notes:• Nominal cooling capacities are based on the following conditions: return air temperature. : 27°C DB,19°C WB,outdoor temperature.:35°C DB, equivalent ref. Piping: 8m(horizontal)• Nominal heating capacities are based on the following conditions: return air temperature.: 20°C DB,outdoor temperature.: 7°C DB, 6°C WB,equivalent ref. Piping: 8m(horizontal)• Sound level is measured at 1.4m below the unit.

36

Four-way Cassette - Specifications

Heating capacity

Model

Cooling capacitykW 2.8

3.2

65650.40.4

1,187/847/766/640699/498/450/376

42/38/35

24/28

6/9Φ6.35

Φ12.7ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

2,400

2,800

10,900

9,600

4.5

5.0

75750.40.4

1,121/864/755/658660/508/444/387

42/38/35

26/30

6/9Φ6.35

Φ12.7ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

1-phase, 220-240V, 50Hz

R410AEXV

3,900

4,300

17,100

15,400

3.6

4.0

65650.40.4

1,187/847/766/640699/498/450/376

42/38/35

24/28

6/9Φ6.35

Φ12.7ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

3,100

3,400

13,600

12,300

5.6

6.3

75750.40.4

1,121/864/755/658660/508/444/387

42/38/35

26/30

6/9Φ9.53

Φ15.9ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

4,800

5,400

21,500

19,100

7.1

8.0

82820.50.5

1,385/1,157/955/749815/680/562/440

45/42/39

26/30

6/9Φ9.53

Φ15.9ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

6,100

6,900

27,300

24,200kcal/h

kcal/h

Btu/h

Btu/h

W

A

CFM

db(A)

Type

mm

mm

mmmmmm

kg

kg

Control method

kW

Power inputCooling

Cooling

Net dim.(W×H×D)

Net dim.(W×H×D)

Gross dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Net/gross

L (flare)G (flare)

Heating

HeatingRated current

Airflow rate (SH/H/M/L)

Sound pressure level (H/M/L)

Refrigerant

Body

Panel

Standard controller Wireless remote controller(RM05/BG(T)E-A)

Drain piping

Piping connections

m /h3

MDV-D28Q4/N1-D MDV-D36Q4/N1-D MDV-D45Q4/N1-D MDV-D56Q4/N1-D MDV-D71Q4/N1-D

Heating capacity

Model

Cooling capacitykW 8.0

9.0

97

970.5

0.5

1,431/1,236/973/729842/727/572/429

45/42/39

26/30

6/9Φ9.53

Φ12.7ODΦ32

904×230×840955×260×955

950×54.5×9501035x90x1035

6,900

7,700

30,700

27,300

10.0

11.1

160

1600.7

0.7

1,758/1,540/1,300/1,1201,035/906/765/659

48/45/43

32/37

6/9Φ9.53

Φ12.7ODΦ32

904×300×840955×330×955

950×54.5×9501035x90x1035

1-phase, 220-240V, 50Hz

R410AEXV

8,600

9,500

37,900

34,100

9.0

10.0

160

1600.7

0.71,758/1,540/1,300/1,1201,035/906/765/659

48/45/43

32/37

6/9Φ9.53

Φ12.7ODΦ32

904×300×840955×330×955

950×54.5×9501035x90x1035

7,700

8,600

34,100

30,700

11.2

12.5

160

1600.7

0.7

1,758/1,540/1,300/1,1201,035/906/765/659

48/45/43

32/37

6/9Φ9.53

Φ15.9ODΦ32

904×300×840955×330×955

950×54.5×9501035x90x1035

9,600

10,800

42,700

38,200

14.0

15.0

170

1700.8

0.8

1,843/1,800/1,500/1,2801,085/1,059/883/753

50/47/44

32/37

6/9Φ9.53

Φ15.9ODΦ32

904×300×840955×330×955

950×54.5×9501035x90x1035

12,000

12,900

51,200

47,800kcal/h

kcal/h

Btu/h

Btu/h

W

A

CFM

db(A)

Type

mm

mm

mmmmmm

kg

kg

Control method

kW

Power inputCooling

Cooling

Net dim.(W×H×D)

Net dim.(W×H×D)

Gross dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Net/gross

L (flare)G (flare)

Heating

HeatingRated current

Airflow rate (SH/H/M/L)

Sound pressure level (H/M/L)

Refrigerant

Body

Panel

Standard controller Wireless remote controller(RM05/BG(T)E-A)

Drain piping

Piping connections

m /h3

MDV-D80Q4/N1-D MDV-D90Q4/N1-D MDV-D100Q4/N1-D MDV-D112Q4/N1-D MDV-D140Q4/N1-D

Indo

or R

ange

Page 37: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

37

Model MDV-D18T3/N1-C MDV-D22T3/N1-C MDV-D28T3/N1-C MDV-D36T3/N1-C MDV-D45T3/N1-C MDV-D56T3/N1-C MDV-D71T3/N1-C

Power supply

Cooling Capacity

Heating Capacity

Rated input

Rated current

Airflow rate (SH/H/M/L)

Standard controller

External Static Pressure

Indoor Unit

Piping connections

Refrigerant type

External Static Pressure

kW

kcal/h

Btu/h

1.8

1500

6100

2.2

1900

7500

59

59

0.31

0.31

2.2

1900

7500

2.6

2200

8900

59

59

0.31

0.31

2.8

2400

9600

3.2

2800

10900

59

59

0.31

0.31

3.6

3100

12300

4

3400

13600

65

65

0.36

0.36

4.5

3900

15400

5

3900

17100

105

105

0.36

0.36

5.6

4800

19100

6.3

5400

21500

105

105

0.36

0.36

7.1

6100

24200

8

6900

27300

130

130

0.5

0.5

10(10~30)

35/27/24

R410A

EXV

740×210×470

910×230×510

14/17.5

Ф6.35

Ф12.7

Ф25

10(10~30)

35/27/24

R410A

EXV

740×210×470

910×230×510

14/17.5

Ф6.35

Ф12.7

Ф25

10(10~30)

35/27/24

R410A

EXV

740×210×470

910×230×510

14/17.5

Ф6.35

Ф12.7

Ф25

10(10~30)

38/32/28

R410A

EXV

740×210×470

910×230×510

14/17.5

Ф6.35

Ф12.7

Ф25

10(10~30)

39/32/29

R410A

EXV

960×210×470

1130×230×510

17.5/22

Ф6.35

Ф12.7

Ф25

10(10~30)

39/32/29

R410A

EXV

960×210×470

1130×230×510

17.5/22

Ф9.35

Ф15.9

Ф25

10(10~30)

41/33/30

R410A

EXV

1180×210×470

1350×230×510

21/26.5

Ф9.35

Ф15.9

Ф25

kW

kcal/h

Btu/h

W

A

m³/h

CFM

dB(A)

606(30pa)/578/512/409 646(30pa) 1207(30pa)803(30pa)617/551/441 1060/970/811

824/690/609

357/340/301/241 380/363/324/260 710/624/571/477473/485/406/358

Wireless remote controller (RM05/BG(T)E-A)

mm

mm

Kg

mm

mm

mm

Type

Control

Pa

CoolingHeating

CoolingHeating

Dimension (WxHxD)Packing (WxHxD)Net (Gross)

L (flare)G (flare)Drain piping

220-240V~1Ph~50Hz

Notes: • Nominal cooling capacities are based on the following conditions: return air temp.: 27°C DB, 19°CWB, and outdoor temp.:35°C DB, equivalent ref. piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: return air temp.: 20°C DB, outdoor temp.: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal) • Sound level is measured at 1.4m below the air outlet.• * External static pressure is based on high speed indoor air flow.

Low Static Pressure Duct - Specifications

Indo

or R

ange

Page 38: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

38

Fresh AirAuto Addressing

Anti-Cold Air Function

Built-in Drain Pump

Super High Air Flow

Follow Me

Wired remote controller

Auto Re-Start

Flexible control and easy maintenance

Convenient installation

Compact size

Air intake from back Air intake from below drain pump as standard

External static pressure

Only 210mm (15~71 models) or 270mm (80 to 112 models) or 300mm (140 model) in height.

Four speed fan motor (Super high speed is optional)Change the wiring connection from ‘SH’ to ‘H’ to change the ESP.

Standard wired remote controller KJR-29B1/BK-E.The electrical control box can be removed 1m away from the unit for easy maintenance access. Customers need to request this service in advance for it is done at Midea CAC factory.Standard functional ports are included such as Remote On/Off Dry contact switch and Alarm signal output (220V).

The EXV is fixed inside of the indoor unit.Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction.Suction chamber is included as standard equipment.Fresh air hole, air inlet/outlet flange are standard for easy duct connection.A rear air inlet is standard and an inlet at the bottom is optional. Both use the same connectible duct.

Concealed Duct Unit (A5 Type)

Indo

or R

ange

Page 39: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

39

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor temperature:35°C DB, equivalent ref. piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured at 1.4m below the air out-let. * External static pressure is based on high speed indoor air flow. • * Specifications are subject to change without prior notice for product improvement.

Model

Power Supply

Cooling Capacity

Heating Capacity

Rated Input

Rated Current

Model

Power Supply

Capacity

Standard Controller

Piping Connections

Piping Connections

Indoor Unit

Refrigerant

Refrigerant

Net dimension

Net/Gross Weight

Packing dimension

Standard controller

Sound Pressure Level (H/M/L)

Sound Pressure Level (H/M/L)

ESP (external static pressure)

ESP (external static pressure)

Indoor air flow (SH/H/M/L)

Power (Cooling)

Power (Heating)

kW

kW

1-phase,220-240V,50Hz

588(30pa)/538/456/375614(30pa)/597

/514/429763(30pa)/811

/684/575763(30pa)/811

/684/575361/351/303/253 449/477/403/338 449/477/403/338346/317/268/221

MDV-D15T2/N1-DA5

MDV-D71T2/N1-DA5

MDV-D80T2/N1-BA5

MDV-D90T2/N1-BA5

MDV-D112T2/N1-BA5

MDV-D140T2/N1-BA5

MDV-D22T2/N1-DA5

MDV-D28T2/N1-DA5

MDV-D36T2/N1-DA5

MDV-D45T2/N1-DA5

MDV-D56T2/N1-DA5

kcal/h

kcal/h

Btu/h

Btu/h

kW

kW

kcal/h

kcal/h

W

W

A

A

Btu/h

Btu/h

W

A

m³/h

m³/h

CFM

CFM

Pa

Pa

dB(A)

dB(A)

mm

mm

mmmm

mm

Kg

1.5 2.2 2.8 3.6 4.5 5.6

1290 1900 2400 3100 3900 4800

5100 7500 9600 12300 15400 19100

1.7 2.6 3.2 4 5 6.3

1500

56

0.31 0.31 0.31 0.33 0.36 0.36

57 57

2200 2800 3400

61

4300

98

5400

103

5800

56

0.31

10(10-30) 10(10-30) 10(10-30) 10(10-30) 10(10-30) 10(10-30)

35.8/34.6/31.4

740x210x500

870×285×525

17.5/20.5

Ф6.35

Ф12.7

Ф15.9 Ф15.9 Ф15.9 Ф15.9 Ф15.9

Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53

7.1 8 9 11.2 14

6100 6900 7700 9600 12000

24 200 27 300 30 700 38 200 47 800

27 300 30 700 34 100 42 700 52 900105 198 200 313 274

0.47 1.0 1.0 1.8 1.55

105 198 200 313 274

0.47 1.0 1.0 1.8 1.55

663/606/550/460 817/792/686/596 817/792/686/596 1,089/1,059/916/824 1,027/1121/963/82410(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100)

41.4/39/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0

1,180x210x500 1,230×270×775 1,230×270×775 1,230×270×775 1,290×300×8651,335x285x525 1,355×350×795 1,355×350×795 1,355×350×795 1,400×375×925

28/31.5 38/46.5 40/48 40/48 49/58

1127(30pa)/1029/934/781 1388(50pa)/1345/1165/1013 1388(50pa)/1345/1165/1013 1851(80pa)/1800/1556/1400 1745(100pa)/1905/1636/1400

8 9 10 12.5 15.5

6900 7700 8600 10800 13300

OD Ф25

OD Ф25 OD Ф25 OD Ф25 OD Ф25 OD Ф25

OD Ф25 OD Ф25 OD Ф25 OD Ф25 OD Ф25

Ф6.35

Ф12.7

Ф6.35

Ф12.7

Ф6.35

Ф12.7

Ф6.35

Ф12.7

Ф9.53

Ф15.9

17.5/20.5 17.5/20.5 17.5/20.5 22.5/26 22.5/26

870×285×525 870×285×525 870×285×525 1,115x285x525 1,115x285x525

740x210x500 740x210x500 740x210x500 960x210x500 960x210x500

36/35/32 37/35/32

R410A

R410A

220~240V-1Ph-50Hz

EXV

EXV

Wired controller KJR-29B1/BK-E (6 meters connection wire)

Wired controller KJR-29B1/BK-E (6 meters connection wire)

38.6/37.5/33.8 39/37.9/34 39/37.9/34

0.31 0.31 0.33 0.36 0.36

57 57

8900 10900 13600

61

17100

98

21500

103

TypeControl method

mm

mmL (flare)

L (flare)

G (flare)

G (flare)

Drain piping

Drain piping

mm

mm

Kg

Net dim. (WxHxD)

Gross dim. (WxHxD)

Net Gross

Cooling

Cooling

Cooling

Heating

Heating

Input

InputRated current

Rated current

TypeControl method

WxHxD

WxHxD

Heating

Airflow Rate (SH/H/M/L)

Concealed Duct Unit (A5 Type) - Specifications

Indo

or R

ange

Page 40: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

40

Auto Addressing

Follow Me

Anti-Cold Air Function

Wired controllerConnectible To Duct

Auto Re-Start

Flexible duct design

Greater flexibility with the four-speed fan

Convenient installation

Flexible control and convenient for maintenance

Option Flexible control and convenient for maintenance

Drain pump with 750mm pump head is optional(models 71 to 160)

Double-skin drainage pan provide double protection for ceilings (models 71 to 160 and models 400 to 560)

External static pressure can be up to 196Pa (models 71 to 160) or 280Pa (models 200 to 560).

Four speed fan motor (model 71 to 160)

The EXV is fixed inside the indoor unit (models 70-160), requires no extra connection.Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction.Flange for air in/outlet duct connection is standard.

Wired remote controller KJR-29B1/BK-E is as standard, and wireless remote controller RM05/BG(T)E-A is as an option.The display board is connected to the E-box in factory, easier troubleshooting by LED display.Easy access filters both at the rear & bottom. Standard functional port such as remote on/off dry contact.

The maximum distance for air supply is about 14m at height of 6.5m.With a 420mm (models 71 to 160) thick body, the minimum distance required above the ceiling is 450mm.

High Static Pressure Duct

Indo

or R

ange

Page 41: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

41

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor temperature:35°C DB, equivalent ref. piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal)• Sound level is measured at 1.4m below the air out-let. *External static pressure is based on high speed indoor air flow.• *Specifications are subject to change without prior notice for product improvement.

Model

Power Supply

Capacity

Model

Power Supply

Capacity

Piping Connections

Piping Connections

Refrigerant

Refrigerant

Net dimension

Net dimension

Net/Gross Weight

Net/Gross Weight

Packing dimension

Packing dimension

Standard controller

Standard controller

Sound Pressure Level (H/M/L)

Sound Pressure Level (H/M/L)

ESP (external static pressure)

ESP (external static pressure)

Indoor air flow (SH/H/M/L)

Indoor air flow (SH/H/M/L)

Power (Cooling)

Power (Cooling)

Power (Heating)

Power (Heating)

kW

kW

MDV-D71T1/N1-B

MDV-D200T1/N1-B

MDV-D80T1/N1-B

MDV-D250T1/N1-B

MDV-D90T1/N1-B

MDV-D280T1/N1-B

MDV-D112T1/N1-B

MDV-D400T1/N1

MDV-D140T1/N1-B

MDV-D450T1/N1

MDV-D160T1/N1-B

MDV-D560T1/N1

kcal/h

kcal/h

Btu/h

Btu/h

kW

kW

kcal/h

kcal/h

W

W

W

W

A

A

A

A

Btu/h

Btu/h

m³/h

m³/h

CFM

CFM

Pa

Pa

dB(A)

dB(A)

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg

Kg

Ф15.9

Φ15.9×2

Ф15.9

Φ15.9×2

Ф15.9

Ф15.9

Ф15.9

Ф22.2x2

Ф15.9

Ф22.2x2

Ф15.9

Ф28.6×2

Φ9.53

Φ9.53×2

Φ9.53

Φ9.53×2

Φ9.53

Φ9.53×2

Φ9.53

Ф12.7×2

Φ9.53

Ф12.7×2

Φ9.53

Ф15.9×2

7.1

20

8

25

9

28

11.2

40

14

45

16

56

6100

17200

6900

21500

7700

24100

9600

34400

12000

38700

13800

48200

24 200

68 200

27 300

85300

30 700

95500

38 200

136500

47 800

153500

54 600

191100

27 300

76 800

30 700

88700

34 100

107500

42 700

153500

54 600

170600

58 000

214960

263

1516

263

1516

423

1516

524

2700

724

2700

940

3400

1.23

8.6

1.23

8.6

1.87

8.6

2.3

12.5

2.85

12.5

4.77

15.5

263

1516

263

1516

423

1516

524

2700

724

2700

940

3400

1.23

8.6

1.23

8.6

1.0

8.6

2.3

12.5

2.85

12.5

4.77

15.5

849/801/717

2,260/2,116/1,748

883/788/718

2,260/2,116/1,748

1,148/1,025/893

2,260/2,116/1,748

1,246/1,140/895

4,398/3,574/2,940

1,766/1,541/1,310

4,398/3,574/2,940

2,131/1,792/1,615

5,621/4,679/3,884

25(25~196)

200(50~280)

37(37~ 196)

200(50~280)

37(37~ 196)

200(50~280)

50(50~ 196)

200(50~280)

50(50~ 196)

200(50~280)

50(50~ 196)

200(50~280)

48/46/44

59/55/52

48/46/44.5

59/55/52

52/49/47

59/55/52

52/49/47

61/59/56

53/50/48

61/59/56

54/52/50

63/60/57

952×420×690

1,443×470×810

952×420×690

1,443×470×810

952×420×690

1,443×470×810

952×420×690

1,970×668×902.5

1,300×420×691

1,970×668×902.5

1,300×420×691

1,970×668×902.5

1,090×440×768

1,509×550×990

1,090×440×768

1,509×550×990

1,090×440×768

1,509×550×990

1,090×440×768

2,095×800×964

1,436×450×768

2,095×800×964

1,436×450×768

2,095×800×964

45/50

115/129

45/50

115/129

46.5/52.4

115/129

50.6/56

232/245

68/70

232/245

70/77.5

235/250

1,443/1,361/1,218

3,840/3,595/2,970

952×420×690

3,840/3,595/2,970 3,840/3,595/2,970

1,951/1,741/1,518 2,116/1,936/1,520

7,472/6,072/4,995

3,000/2,618/2,226

7,472/6,072/4,995

3,620/3,044/2,744

9,550/7,950/6,600

8

22.5

9

26

10

31.5

12.5

45

15.5

50

17

63

6900

19 400

7700

22400

8600

27100

10800

38700

13800

43000

14600

54200

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

OD Ф32

R410A

R410A

220~240V-1Ph-50Hz

220~240V-1Ph-50Hz

EXV

EXV

Wired controller KJR-29B1/BK-E (6 meters connection wire)

Wired controller KJR-29B1/BK-E (6 meters connection wire)

L (flare)

L (flare)

G (flare)

G (flare)

Drain piping

Drain piping

Cooling

Cooling

Heating

Heating

Input

Input

Input

Input

Rated current

Rated current

Rated current

Rated current

Type

Type

Control method

Control method

WxHxD

WxHxD

WxHxD

WxHxD

High Static Pressure Duct - Specifications

Indo

or R

ange

Page 42: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

42

Auto Addressing

Follow Me

Anti-Cold Air Function

Auto Re-Start

Convenient installation

Quiet and comfortable environment

Auto swing and wide angle air flow

The unit can be installed either horizontally on the ceiling or vertically against the wall.

• The unit even can be easily installed at the corner of a narrow ceilings.• It is especially useful when central installation is impossible due to features such as lights.

• The slim and sleek design starting at just 30kg enables quick, easy and neat installation.• Low noise operations; minimum 36 dB(A)

1. Auto horizontal and auto vertical swing functions for more even and comfortable airflow.2. Three air flow speeds: low, medium and high; double air guides.3. Adopt electrical expansion valve, ensuring precise flow control, lower modulation noise when EXV operating.4. Smoother airflow and less turbulence due to the multi-blade fan and the air guide design.

Cleanable PanelLED DisplayLEDDisplay

Ceiling & Floor

Indo

or R

ange

Page 43: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

43

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor temperature:35°C DB, equivalent ref. piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal)• Sound level is measured at 1.4m below the air out-let. • * External static pressure is based on high speed indoor air flow. * Specifications are subject to change without prior notice for product improvement.

Model

Power Supply

Capacity

Model

Power Supply

Capacity

Piping Connections

Piping Connections

Refrigerant

Refrigerant

Net dimension

Net dimension

Gross Weight

Gross Weight

Net Weight

Net Weight

Packing dimension

Packing dimension

Standard controller

Standard controller

Sound Pressure Level (H/M/L)

Sound Pressure Level (H/M/L)

Indoor air flow (H/M/L)

Indoor air flow (H/M/L)

Power (Cooling)

Power (Cooling)

Power (Heating)

Power (Heating)

kW

kW

MDV-D36DL/N1-C

MDV-D90DL/N1-C

MDV-D45DL/N1-C

MDV-D112DL/N1-C

MDV-D56DL/N1-C

MDV-D140DL/N1-C

MDV-D71DL/N1-C

MDV-D160DL/N1-C

MDV-D80DL/N1-C

kcal/h

kcal/h

Btu/h

Btu/h

kW

kW

kcal/h

kcal/h

W

W

W

W

A

A

A

A

Btu/h

Btu/h

m³/h

m³/h

CFM

CFM

dB(A)

dB(A)

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg

Kg

Kg

Kg

Ф12.7

Ф15.9

Ф12.7

Ф15.9

Ф15.9

Ф15.9

Ф15.9

Ф15.9

Ф15.9

Φ6.35

Φ9.53

Φ6.53

Φ9.53

Φ9.53

Φ9.53

Φ9.53

Φ9.53

Φ9.53

3.6

9

4.5

11.2

5.6

14

7.1

16

8

3100

7700

3900

9600

4800

13300

6100

13800

6900

12300

30700

15400

38200

19100

47800

24200

54600

27300

13600

34100

17100

42700

21500

51200

27300

61400

3070049

130

120

182

122

182

125

300

130

0.23

0.83

0.67

1.11

0.67

1.11

0.67

1.41

0.83

49

130

120

182

122

182

125

300

130

0.23

0.83

0.67

1.11

0.67

1.11

0.67

1.41

0.83

383/335/294

706/530/412

471/353/294

1,165/1,095/1,018

471/353/294

1,165/1,095/1,018

471/353/294

1,165/1,095/1,018

706/530/412

40/38/36

45/43/40

43/41/38

47/45/42

43/41/38

47/45/42

43/41/38

47/45/42

45/43/40

990×203×660

1,280×203×660

990×203×660

1,670×244×680

990×203×660

1,670×244×680

990×203×660

1,670×285×680

1,280×203×6601,089×296×744

1,379×296×744

1,089×296×744

1,764×329×760

1,089×296×744

1,764×329×760

1,089×296×744

1,775×377×760

1,379×296×744

32

41

34

59

34

59

34

63.5

41

26

34.5

28

54

28

54

28

57.5

34.5

650/570/500

1,200/900/700

800/600/500

1,980/1,860/1,730

800/600/500

1,980/1,860/1,730

800/600/500

1,980/1,860/1,730

1,200/900/700

4

10

5

12.5

6.3

15

8

18

9

3400

8600

4300

10800

5400

12900

6800

15500

7700

OD Ф16

OD Ф16

OD Ф16

OD Ф16

OD Ф16

OD Ф16

OD Ф16

OD Ф16

OD Ф16

R410A

R410A

1-phase, 220-240V, 50Hz

1-phase, 220-240V, 50Hz

EXV

EXV

Wireless remote controller(RM05/BG(T)E-A)

Wireless remote controller(RM05/BG(T)E-A)

L (flare)

L (flare)

G (flare)

G (flare)

Drain piping

Drain piping

Cooling

Cooling

Heating

Heating

Input

Input

Input

Input

Rated current

Rated current

Rated current

Rated current

Type

Type

Control method

Control method

WxHxD

WxHxD

WxHxD

WxHxD

Ceiling & Floor - Specifications

Indo

or R

ange

Page 44: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

44

Panel with LED display

The front panel and display panel have different colors to choose: white and brown for big panel, blue and brown for small panel.

Follow Me

Auto Re-Start

Convenient installation

Auto Addressing

Anti-Cold Air Function

Cleanable Panel

LED DisplayLEDDisplay

• Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation.• For S panel,R panel & C panel , the EXV is built-in the indoor unit, compact size , longer the connection pipe;gas pipe: 468mm;liquid pipe:550mm,more flexible for installation. • For D panel, the EXV can be 5m far away from the indoor unit, which lower the noise. Adopts new type fixing plate, is easy to install and stable.

Auto swing louver Easy maintenance

The Auto Swing Louver function ensures that the air direction corresponds to the mode selected.

The front panel can be removed for easy maintenance access.

Optimal comfort through better flow control and quiet operations

The mechanical expansion valve offers 2,000-stage element positions to ensure precise flow control and less modulation noise when the EXV is operating for a quiet and comfortable environment. Three air flow speeds: low, medium and high; double air guides. Smoother airflow and less turbulence is ensured by the multi-blade fan and the air guide design.

Step

Swing

1

4

2

3

Wall-mounted

Indo

or R

ange

Page 45: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

45

1-phase,220-240V,50Hz

Mode MDV-D15G/N1-S MDV-D22G/N1-S MDV-D28G/N1-S MDV-D45G/N1-S

Power supply

R410A

EXV

1.5 2.82.2 3.6 4.5

1290 24001900 3100 3900

5100 96007500 12300 15400

1.7 3.22.4 4 5

1470 28002100 3400 4300

5800 109008200 13600 17100

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

MDV-D36G/N1-S

kWkcal/h

Btu/h

HeatingW

28 2828 28 45

28 2828 28 45

Cooling Rated current

HeatingA

0.12 0.140.14 0.14 0.2

0.13 0.140.14 0.14 0.2

m³/h

dB(A)

CFM

427/389/336 525/480/430525/480/430 590/520/480 860/755/630

251/229/198 309/283/253309/283/253 347/306/283 506/444/371

33/31/28 35/32/2935/32/29 35/32/29 40/38/32

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Piping connections

Indoor Unitmm

kg

915x230x290

1,020x315x390

12.4/15.9

mm

mm

mm

Ф6.35

Ф12.7

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

915x230x290

1,020x315x390

13/16.8

Ф6.35

Ф12.7

ODФ16.5

915x230x290

1,020x315x390

13/16.8

Ф6.35

Ф12.7

ODФ16.5

915x230x290

1,020x315x390

13/16.8

Ф6.35

Ф12.7

ODФ16.5

1072x230x315

1,180x315x415

15.1/19.5

Ф6.35

Ф12.7

ODФ16.5

MDV-D56G/N1-S

5.6

4800

19100

6.3

5400

21500

45

45

0.2

0.2

925/860/755

544/506/444

40/38/34

1072x230x315

1,180x315x415

15.1/19.5

Ф9.53

Ф15.9

ODФ16.5

Net dim.(WxHxD)

Gross dim.(WxHxD)

Net/Gross

1-phase,220-240V,50Hz

Mode MDV-D22G/N1-S MDV-D28G/N1-S MDV-D45G/N1-S

Power supply

R410A

EXV

2.2 2.8 3.6 4.5

1,900 2,400 3,100 3,900

7,500 9,600 12,300 15,400

2.4+0.75 3.2+0.75 4+0.75 5+0.9

2,100+600 2,800+600 3,400+600 4,300+800

8,200+2,600 10,900+2,600 13,600+2,600 17,100+3,100

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

MDV-D36G/N1-S

kWkcal/h

Btu/h

HeatingW

28 28 28 45

28 28 28 45

Cooling Rated current

HeatingA

0.14 0.14 0.14 0.2

0.14+3.38 0.14+3.38 0.14+3.38 0.20+4.05

m³/h

dB(A)

CFM

525/480/430 525/480/430 590/520/480 860/755/630

309/283/253 309/283/253 347/306/283 506/444/371

35/32/29 35/32/29 35/32/29 40/38/32

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Piping connections

mm

kg

915x230x290

1,020x315x390

13.3

mm

mm

mm

Ф6.35

Ф12.7

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

915x230x290

1,020x315x390

13.3

Ф6.35

Ф12.7

ODФ16.5

915x230x290

1,020x315x390

13.3

Ф6.35

Ф12.7

ODФ16.5

1072x230x315

1,180x315x415

15.5

Ф6.35

Ф12.7

ODФ16.5

MDV-D56G/N1-S

5.6

4,800

19,100

6.3+0.9

5,400+800

21,500+3,100

45

45

0.2

0.20+4.05

925/860/755

544/506/444

40/38/34

1072x230x315

1,180x315x415

15.5

Ф9.53

Ф15.9

ODФ16.5

kg

mmNet dimension (WxHxD)

Net weight

Packing dimension (W×H×D)

Gross weight

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor temperature:35°C DB, equivalent ref. Piping: 8m (horizontal)• Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal)• Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance. • * Specifications are subject to change without prior notice for product improvement.

17.1 17.1 17.1 19.9 19.9

Wall-mounted - S Type Panel - Specifications

Indo

or R

ange

Page 46: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

46

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°CWB, and outdoor temperature:35°C DB, equivalent ref. Piping: 8m (horizontal)• Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal)• Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance. • * Specifications are subject to change without prior notice for product improvement.

Mode MDV-D22G/N1YB MDV-D28G/N1YB MDV-D36G/N1YB MDV-D56G/N1YB

Power supply

R410A

EXV

2.2 3.62.8 4.5 5.6

1,900 3,1002,400 3,900 4,800

7,500 12,3009,600 15,400 19,100

2.4 43.2 5 6.3

2,100 3,4002,800 4,300 5,400

8,200 13,60010,900 17,000 21,500

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

MDV-D45G/N1YB

kWkcal/h

Btu/h

HeatingW

28 2828 45 45

28 2828 45 45

Cooling Rated current

HeatingA

0.14 0.140.14 0.2 0.2

0.14 0.140.14 0.2 0.2

m³/h

dB(A)

CFM

520/480/430 520/480/430520/480/430 860/755/630 925/860/755

306/283/253 306/283/253306/283/253 506/444/371 544/506/444

35/32/29 35/32/2935/32/29 40/38/34 40/38/34

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

1-phase,220-240V,50Hz

Net dimension (WxHxD)

Piping connections

Net weight

Packing dimension (W×H×D)

mm

kg

915x210x290

1,020x300x385

12

mm

mm

mm

Ф6.35

Ф12.7

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

mm

kgGross weight 17.5

915x210x290

1,020x300x385

12

Ф6.35

Ф12.7

ODФ16.5

17.5

915x210x290

1,020x300x385

12

Ф6.35

Ф12.7

ODФ16.5

17.5

915x210x290

1,020x300x385

15

Ф6.35

Ф12.7

ODФ16.5

19

915x210x290

1,020x300x385

15

Ф9.53

Ф15.9

ODФ16.5

18

Mode MDV-D22G/N1YB MDV-D28G/N1YB MDV-D36G/N1YB MDV-D56G/N1YB

Power supply

R410A

EXV

2.2 3.62.8 4.5 5.6

1,900 3,1002,400 3,900 4,800

7,500 12,3009,600 15,400 19,100

2.4+0.75 4+0.753.2+0.75 5+0.9 6.3+0.9

2,100+600 3,400+6002,800+600 4,300+800 5,400+800

8,200+2,600 13,600+2,60010,900+2,600 17,000+3,100 21,500+3,100

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

MDV-D45G/N1YB

kWkcal/h

Btu/h

HeatingW

28 2828 45 45

28 2828 45 45

Cooling Rated current

HeatingA

0.14 0.140.14 0.2 0.2

0.14+3.38 0.14+3.380.14+3.38 0.2+4.05 0.2+4.25

m³/h

dB(A)

CFM

520/480/430 520/480/430520/480/430 860/755/630 925/860/755

306/283/253 306/283/253306/283/253 506/444/371 544/506/444

35/32/29 35/32/2935/32/29 40/38/34 40/38/34

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

1-phase,220-240V,50Hz

Net dimension (WxHxD)

Piping connections

Net weight

Packing dimension (W×H×D)

mm

kg

915x210x290

1,020x300x385

12

mm

mm

mm

Ф6.35

Ф12.7

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

mm

kgGross weight 17.5

915x210x290

1,020x300x385

12

Ф6.35

Ф12.7

ODФ16.5

17.5

915x210x290

1,020x300x385

12

Ф6.35

Ф12.7

ODФ16.5

17.5

1,070x210x315

1,165x285x395

15

Ф6.35

Ф12.7

ODФ16.5

19

1,070x210x290

1,165x285x395

15

Ф9.53

Ф15.9

ODФ16.5

19

Wall-mounted - C Type Panel - Specifications

Indo

or R

ange

Page 47: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Mode MDV-D71G-R3/N1Y MDV-D80G-R3/N1Y MDV-D90G-R3/N1Y

Power supply

R410A

EXV

87.1 9

6,9006,100 7,700

27,30024,200 30,700

98 10

7,7006,900 8,600

30,70027,300 34,100

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

kWkcal/h

Btu/h

HeatingW

8675 86

8675 86

Cooling Rated current

HeatingA

0.390.33 0.39

0.390.33 0.39

m³/h

dB(A)

CFM

1,320/840/6401190/780/580 1,320/840/640

776/494/376700/459/341 776/494/376

48/43/3847/43/42 49/43/38

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Net dimension (WxHxD)

Piping connections

Net weight

Packing dimension (W×H×D)

mm

kg

1.250x245x3251.250x245x325 1.250x245x325

1,345x335x4301,345x335x430 1,345x335x430

19.919.9 19.9

mm

mm

mm

Ф9.53

Ф15.9

ODФ16.5

Ф9.53

Ф15.9

ODФ16.5

Ф9.53

Ф15.9

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

1-phase,220-240V,50Hz

mm

kgGross weight 2525 25

Mode MDV-D22G/ N1Y-11D5

MDV-D28G/ N1Y-11D5

MDV-D36G/ N1Y-11D5

MDV-D56G/ N1Y-11D5

Power supply

R410A

EXV

2.2 3.62.8 4.5 5.6

1900 31002400 3900 4800

7500 123009600 15400 19100

2.4 43.2 5 6.3

2100 34002800 4300 5400

8200 1360010900 17100 21500

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

MDV-D45G/ N1Y-11D5

kWkcal/h

Btu/h

HeatingW

25 38.729.9 42.1 0.3

25 38.729.9 42.1 61.7

Cooling Rated current

HeatingA

0.13 0.180.15 0.21 61.7

0.13 0.180.15 0.21 0.3

m³/h

dB(A)

CFM

367/295/263 576/419/360491/403/341 724/511/436 1,056/883/741

216/174/155 339/247/212289/237/201 426/301/257 622/520/436

33/31/28 33/31/2833/31/28 38/36/32 38/36/32

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

1-phase,220-240V,50Hz

Piping connections

Indoor Unitmm

kg

680x180x255

885x310x395

6.5/11.9

mm

mm

mm

Ф6.35

Ф12.7

ODФ16.5

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)

G (flare)

Drain piping

770x190x255

975x310x395

7.4/12.8

Ф6.35

Ф12.7

ODФ16.5

770x190x255

975x310x395

7.4/12.8

Ф6.35

Ф12.7

ODФ16.5

905x205x275

1,110x310x395

9.1/14.7

Ф6.35

Ф12.7

ODФ16.5

1,030x220x315

1,024x310x415

12.9/19.2

Ф9.53

Ф15.9

ODФ16.5

MDV-D71G/ N1Y-11D5

7.1

6100

24200

8

6900

27300

0.35

79

79

0.35

1,182/842/702

696/496/413

43/41/38

1,030x220x315

1,024x310x415

12.9/19.2

Ф9.53

Ф15.9

ODФ16.5

Net dim.(WxHxD)

Gross dim.(WxHxD)

Net/Gross

Wall-mounted - R Type Panel - Specifications

Wall-mounted - D Type Panel - Specifications

47

Indo

or R

ange

Page 48: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

48

Easy installation

Floor standing types can be hung on the wall or installed on the floor. The floor type of unit can make cleaning and maintenance much easier. Running the piping from the rear allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier

Filter is provided as a standard accessory. It can be removed and cleaned easily thanks to Midea’s sophisticated design and the product’s removable blades.

The streamlined appearance harmonizes the unit with a given room’s interior decor. All metal parts are made of commercial grade galvanized steel for maximum protection against corrosion.

Auto Addressing

Follow Me

Anti-Cold Air Function

Wired controllerConnectible To Duct

Auto Re-Start

Easy maintenance

Saves installation space

Concealed floor standing type The body is concealed in the skirting board to improve aesthetics. The body is just 212mm deep, and can be installed at the room’s perimeter.Special installation methods eliminate noise in the room area.

F3B series concealed type Air intake from front (F4 series) Air intake from below (F5 series)

Floor Standing

Indo

or R

ange

Page 49: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

49

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°CWB, and outdoor temperature:35°C DB, equivalent ref. Piping: 8m (horizontal)• Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal) • Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance.• * Specifications are subject to change without prior notice for product improvement.

Mode MDV-D22Z/N1-F3B

MDV-D28Z/N1-F3B

MDV-D36Z/N1-F3B

MDV-D56Z/N1-F3B

MDV-D80Z/N1-F3B

Power supply

R410AEXV

2.2 3.62.8 4.5 5.61900 31002400 3900 48007500 123009600 15400 191002.4 43.2 5 6.3

2100 34002800 4300 54008200 1360010900 17100 21500

1-phase,220-240V,50Hz

Cooling Capacity kW

Cooling

kcal/hBtu/h

Heating Capacity

Rated input

Ф6.35

MDV-D45Z/N1-F3B

MDV-D71Z/N1-F3B

7.1610024200

8690027300

8690027300

9770030700

kWkcal/hBtu/h

HeatingW 40 4646 49 88

40 4646 49 88130130

130130

Cooling Rated current Heating A 0.18 0.220.21 0.22 0.4

0.18 0.220.21 0.22 0.40.560.56

0.590.59

m³/h

dB(A)CFM

530/456/400 624/522/375569/485/421 660/542/440 1150/970/830312/268/235 367/307/221335/285/248 388/319/259 677/571/489

1380/1100/870812/647/512

1380/1100/870812/647/512

36/33/29 37/34/2936/33/29 37/34/30 41/35/31 44/39/33 44/39/33

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Indoor Unit

Piping connections

Net dim.(WxHxD)

NetGrossGross dim.(WxHxD)

mm

kg

840x544x212 1036x544x212840x544x212 1036x544x212 1336x544x212939x639x305 1139x639x305939x639x305 1139x639x305 1425x639x305

1336x544x2121425x639x305

1336x544x2121425x639x305

25/27 29.5/3425/27 29.5/34 33/39 33/39 36/40

Ф12.7mmmmmm ODФ16

Ф6.35Ф12.7

ODФ16

Ф6.35Ф12.7

ODФ16

Ф6.35Ф12.7

ODФ16

Ф9.53Ф15.9

ODФ16

Ф9.53Ф15.9

ODФ16

Ф9.53Ф15.9

ODФ16Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L (flare)G (flare)Drain piping

Mode MDV-D22Z/N1-F5

MDV-D28Z/N1-F5

MDV-D36Z/N1-F5

MDV-D56Z/N1-F5

MDV-D80Z/N1-F5

Power supply

R410AEXV

2.2 3.62.8 4.5 5.61,900 3,1002,400 3,900 4,8007,500 12,3009,500 15,400 19,100

2.4 43.2 5 6.32,100 3,4002,800 4,300 5,4008,200 13,60010,900 17,100 21,500

1-phase,220-240V,50Hz

Cooling Capacity kW

Cooling

kcal/hBtu/h

Heating Capacity

Rated input

MDV-D45Z/N1-F5

MDV-D71Z/N1-F5

7.16,100242,00

86,90027,300

86,90027,300

97,70030,700

kWkcal/hBtu/h

HeatingW 40 4646 49 88

40 4646 49 88130130

130130

Cooling Rated current Heating A 0.18 0.220.19 0.22 0.43

0.18 0.220.19 0.22 0.430.630.63

0.630.63

m³/h

dB(A)

CFM530/456/400 624/522/375569/485/421 660/542/440 1150/970/830312/268/235 367/307/221335/285/248 388/319/259 677/571/489

1380/1100/870812/647/512

1380/1100/870812/647/512

36/33/29 37/34/2936/33/29 37/34/30 41/35/31 44/39/33 44/39/33

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Net dimension(W×H×D)

F4

F5mm

1,000×625×220 1,200×625×2201,000×625×220 1,200×625×220 1,500×625×220

1,000×625×220 1,200×625×2201,000×625×220 1,200×625×220 1,500×625×220

1,500×625×220

1,500×625×220

1,500×625×220

1,500×625×220

Ф6.35Piping connections Ф12.7

mmmmmm ODФ16

Ф6.35Ф12.7

ODФ16

Ф6.35Ф12.7

ODФ16

Ф6.35Ф12.7

ODФ16

Ф9.53Ф15.9

ODФ16

Ф9.53Ф15.9

ODФ16

Ф9.53Ф15.9

ODФ16Standard Controller Wireless remote controller (RM05/BG(T)E-A)

MDV-D22Z/N1-F4

MDV-D28Z/N1-F4

MDV-D36Z/N1-F4

MDV-D56Z/N1-F4

MDV-D80Z/N1-F4

MDV-D45Z/N1-F4

MDV-D71Z/N1-F4

36/33/29 37/34/2936/33/29 37/34/30 41/35/31 44/39/33 44/39/33

F4

F5mm

1,000×625×220 1,200×625×2201,000×625×220 1,200×625×220 1,500×625×220

1,000×625×220 1,200×625×2201,000×625×220 1,200×625×220 1,500×625×220

1,500×625×220

1,500×625×220

1,500×625×220

1,500×625×220

Packing dimension(W×H×D)

F4

F5mm

Net/Grossweight

L(flare)G(flare)Drain piping

30/38

30/38

30/38

30/38

36/44

35.5/41

36/44

35.5/41

41/46.5

42/51

41/46.5

42/51

42.5/48.5

44/53

Floor Standing- Specifications

Indo

or R

ange

Page 50: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

50

Auto Addressing

Follow Me

Anti-Cold Air Function

Auto Re-Start

Cleanable PanelLED DisplayLEDDisplay

Compact size and stylish

• The elegant and thin unit body complements the existing decor and saves space.• The EXV is installed inside of the indoor unit for added compactness.

• Can be installed on the floor or lower wall • As a floor standing type, it can be semi or fully accessed without losing capacity.

Flexible installation

High Comfort

COOLING MODE

• Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches every corner of the room and increases the air flow coverage.• Indoor unit adopts DC motor with five fan speeds to meet different requirements.• Applies the Fujikoki mechanical expansion valve which offers 2,000-stage element positions to ensure precise flow control and lower modulation noise when the EXV is operating.

Powerful mode can be selected for rapid cooling or heating

HEATING MODE

Quick cooling To maintain temperature Anti-cold air Normal operation

Console

Indo

or R

ange

Page 51: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

51

Console- Specifications

High efficiency filter

• Built in formaldehyde nemesis filter• Active-carbon and biological anti-virus filter are optional.

High efficiency filter

Four directions of air inlet; two options of air outlet: Up and Down; or Up only.

Low-noise design

Five-speed indoor unit; low noise; low power consumption.

Bottom, top, and right/left side, for better ventilation. Low noise operation, lowest to 26dB(A)

Notes: • Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor temperature:35°C DB, equivalent ref. Piping: 8m (horizontal)• Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C DB, 6°C WB, and equivalent ref. Piping: 8m (horizontal)• Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance. * Specifications are subject to change without prior notice for product improvement.

Mode MDV-D22Z/DN1-B MDV-D28Z/DN1-B MDV-D36Z/DN1-B

Power supply

R410A

EXV

2.82.2 3.6

2,4001,900 3,100

9,6007,500 12,300

3.22.6 4.0

2,8002,200 3,400

10,9008,900 13,600

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

kW

kcal/h

Btu/h

HeatingW

2520 25

2520 25

Cooling Rated current

HeatingA

0.110.09 0.15

0.110.09 0.15

m³/h

dB(A)

CFM

510/430/229430/345/229 510/430/229

300/253/135253/203/135 300/253/135

39/33/2738/32/26 39/33/27

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Net dimension (WxHxD)

Piping connections

Net weight

Packing dimension (W×H×D)

mm

kg

700x210x600700x210x600 700x210x600

810x305x710810x305x710 810x305x710

1514 15

mm

mm

-

Ф6.35

Ф12.7

ODФ16

Ф6.35

Ф12.7

ODФ16

Ф6.35

Ф12.7

ODФ16

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L(flare)

G(flare)

Drain piping

1-phase,220-240V,50Hz

mm

kgGross weight 2019 20

MDV-D45Z/DN1-B

4.5

3,900

15,400

5.0

4,300

17,100

45

45

0.2

0.2

660/512/400

388/300/235

42/39/36

700x210x600

810x305x710

15

Ф6.35

Ф12.7

ODФ16

20

Air Inlet

Air Outlet

Indo

or R

ange

Page 52: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

52

Air-conditioning Fresh air supply

Healthy and comfortable

Fresh air is imported, provides a healthy and comfortable living environment.Four speed fan motor (model 125 & 140).

Both fresh air filtration and heating/cooling can be achieved in a single system.

Indoor units and fresh air processing unit can be connected to the same refrigerant system, increasing design flexibility and greatly reducing total system costs.

100% Fresh air processing unit

High external static pressure

External static pressure can be up to 196Pa (models 125 to 140) and 280Pa (models 200 to 280) for more flexible duct applications. The maximum distance of air supply is about 14m and the maximum height of air supply is about 6.5m.

Innovative air supply technology for excellent room temperature control

Layout Example:

Outdoor Units

Outdoor Air processing unit

Indoor Unit Indoor Unit

the longest distance of air supply is 4m

Fresh air in take

The height of airsupply is 6.5mAir supply

Air return

INDOOR UNIT

Fresh Air Processing Unit

Indo

or R

ange

Page 53: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

53

ModeMDV-D125T1/

N1-FAMDV-D140T1/

N1-FAMDV-D200T1/

N1-FA

Power supply

R410A

EXV

1412.5 20

1200010800 17200

4780042700 68200

1210.5 18

103009000 15550

4100035800 61400

Cooling Capacity

kW

Cooling

kcal/h

Btu/h

Heating Capacity

Power input

kWkcal/h

Btu/h

HeatingW

430461 1063

430430 1063

Cooling Rated current

HeatingA

2.42.4 5.3

2.42.4 5.3

m³/h

dB(A)

CFM

2,142/1,870/1,6111,300×420×690 3,210/2,700/2,200

1,261/1101/9481,436×1101×948 1,889/1,589/1,295

54/52/5054/52/50 54/53/51

Airflow rate (H/M/L)

Sound pressure level (H/M/L)

Refrigerant Control method

Type

Net dimension (WxHxD)

Piping connections

Net weight

Packing dimension (W×H×D)

mm

kg

1,300×420×6901,300×420×690 1,443×470×810

1,436×450×7681,436×450×768 1,509×550×990

69.569.5 115

mm

mm

-

Ф9.53

Ф15.9

ODФ25

Ф9.53

Ф15.9

ODФ25

Ф9.53

Ф15.9

ODФ32

Standard Controller Wireless remote controller (RM05/BG(T)E-A)

L(flare)

G(flare)

Drain piping

1-phase,220-240V,50Hz

mm

kgGross weight 7676 125

25

21500

85300

20

17200

68200

1063

1063

5.6

5.6

3,205/2,750/2,300

1,886/1,619/1,354

55/54/52

1,443×470×810 1,443×470×810

1,509×550×990 1,509×550×990

115 115

Ф9.53 Ф9.53

Ф15.9 Ф15.9

ODФ32 ODФ32

125 125

28

24100

95500

22

18900

75100

1063

1063

5.6

5.6

3,205/2,750/2,300

1,886/1,619/1,354

55/54/52

MDV-D250T1/N1-FA

MDV-D280T1/N1-FA

Notes: • Nominal cooling capacities are based on the following conditions: outdoor air temperature: 33ºC DB, 24ºC WB, equivalent ref. piping: 8m (horizontal) • Nominal heating capacities are based on the following conditions: outdoor air temperature: 0°C DB, -1°CWB, equivalent ref. Piping: 8m (horizontal)• Sound level is measured 1.4m from the air out-let.

• External static pressure are based on high speed indoor air flow.• Specifications are subject to change without prior notice for product improvement.

Connection Conditions:The following restrictions must be observed in order to maintain the indoor units connected to the same system. When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.• When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.• Outdoor-air processing units can be used without indoor units.• The fresh air processing unit is not available for V4+R system

Fresh Air Processing Unit - Specifications

Indo

or R

ange

Page 54: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Not

e: T

he w

ires

in th

e di

agra

m s

how

the

sign

al fl

ows

only,

w

hile

not

repr

esen

t the

act

ual c

onne

ctin

g w

ays.

Indi

vidu

al c

ontr

olC

entr

aliz

ed C

ontr

ol

Acc

esso

ries

KJR

-10B

KJR

-12B

KJR

-90A

KJR

-29B

RM

02R

M05

R05

R06

R51

R71 Car

d-ke

y In

terf

ace

MD

-NIM

05

Rem

ote

cont

rolle

r

Wire

d co

ntro

ller

Out

door

uni

ts

Car

d-ke

y

Wire

d co

ntro

ller

Wire

d co

ntro

ller

Indo

or C

entr

aliz

ed C

ontr

olle

r(T

ouch

key

)

MD

-CC

M08

Dat

a co

nver

ter

CC

M15

CC

M-1

8A

Mod

bus

gate

way

Con

nect

able

tova

rious

siz

ed G

atew

ay

BA

Cne

t BM

S

Web

mon

itorin

g sy

stem

Mod

bus

BM

S

M-IN

TER

FAC

E G

atew

ayIM

M S

oftw

are

iPad

Lapt

op

MD

-Lon

GW

64Lo

nwor

ks B

MS

Out

door

Cen

tral

ized

M

onito

r

K1,

K2,

E

Indo

or C

entr

aliz

ed

Con

trol

ler

X,Y,

E

X,Y,

E

F1,F

2,E

MD

-CC

M02

MD

-CC

M03

CC

M30

102

Infr

ared

Sen

sor M

D-N

IM09

Infra

red

cont

rol b

ox

Infra

red

sens

or m

odul

e

MD

-NIM

05KJR

-86C

KJR

-120

BK

JR-9

0CK

JR-1

20C

V4+ - Network Control

54

Page 55: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial
Page 56: Midea VRF (V4+) MVRF.pdf · Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

Imperial Air Conditioning (Pty) Ltd Head Office Tel: +27 11 794 5537 I Fax: 0866 136 792 I [email protected]

www.mideaaircon.co.za