• Web Sensors of temperature, humidity, atmospheric pressure and CO2 with two-state inputs

and relay outputs • high quality, accurate and stable sensors • values computed from ambient

temperature and relative humidity • traceable calibration certificate with traceability with

EN ISO/IEC 17025

Monitoring of temperature, humidity,atm. pressure and CO

2 via Ethernet

Page 4: COMET measuring instruments katalog

These days there is a high demand for on-line monitoring and uninterruptable records of different type of values. With very fast development of computer technologies, it is still easier and easier to con-nect different kind of monitoring devices directly to Ethernet lines, to the places where it was not possible before. If the Ethernet net has direct connection to the internet, then all data could be sent immediately around the world without the need for any additional costs. This high requirements could be done easily by Web Sensors and sensors with Ethernet output which can ensure long term reliability, stable parameters and very easy installation and usage. The devices can be protected against blackouts and data loss at the customer’s site. Of course PoE supply is an option. Continuous monitoring of critical parameters such as temperature and relative humidity can be very easily done by the help of Web Sensors. This production line consists of sensors for measuring temperature, relative humidity, CO2 concentration, atmospheric pressure, and the 4-20mA signal. Most sensors are equipped with an LCD display and can be easily incorporated into the existing network infrastructure. The Web Sensors evaluate the measured values and in case of exceeding the alarm limits, the unit will send an email to a pre-set address, so this ensures that you are always informed of the conditions in your offices, server rooms, warehouses and factories, and everywhere where is necessary to monitor the supported values .By connecting directly to a computer network the thermometer or humidity meter can be integrated into the control systems of different manufacturers using SNMP, MODBUS TCP, SOAP, syslog. Of course data in many formats is also available, for example XML and so on.

TemperatureTemperature is measured by RTD sensor Pt1000/3850 ppm which can be integrated into the housing of transducer, into the duck stem or can be used on the cable as well. The measu-red temperature can be displayed in °C or °F, according to the settings of the sensor.

State-of-the-art capacitive polymer sensor ensures excellent long term calibration stabilityand inertia against water and condensation. Transmitters are available in wall-mount, duct mount.

Relative humidity

Transmitter for measuring of barometric pressure is equipped with an absolute pressure sensor of high accuracy which ensures excellent long term stability. The display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

Barometric pressure

A multiple point CO2 and temperature adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications. The dual wavelength NDIR CO2 sensing procedu-re compensates automatically for ageing effects. The CO2 module is highly insensitive to pollution and offers maintenance free operation and outstanding long term stability.

Carbon dioxide level - CO2

» Server rooms» Offices and residential premises» Building management» Storage of food and drugs» Museums and galleries» Technological processes and production» Industry

Current - mATransfer of current loops 0-20 mA (4-20 mA) to the Ethernet network. Ethernet network reduces installation costs and accelerates deployment.

Binary inputsSelected devices feature up to three binary inputs for connecting smoke detectors, floo-dings, breaking glass, door contacts, etc. A voltage-free contact, open collector or two-state voltage signal can be connected.

Computed values:

Dew point temperature (°C or °F)Absolute humidity (g/m3)Specific humidity (g/kg)Mixing ratio (g/kg)Specific enthalpy (kJ/kg)

Applications of Web Sensors:

Applications

Measured values

Page 5: COMET measuring instruments katalog

Měřící a záznamový systém MS v různých provedeních

3

Pharmaceuticals and laboratories Technological processes and production

Server rooms Food industry

Monitoring of areas and places for storage of drugs at temperatures down to - 200 °C.

Monitoring of storage conditions and production processes in the temperature range from - 200 °C to + 600 °C.

Monitoring of critical variables in relation to HACCP regulations with the possibility of immediate alert to unforeseen events that could lead to the devaluation of goods.

Monitoring of conditions in the data centers and in 19” racks, including detection of the state of flooding, opening / closing doors (windows), movement and smoke, etc.

Page 6: COMET measuring instruments katalog

WWW serverActual measured values are accessible via powerful embedded web server. Web pages are ready for access from mobile devices like smartphones and tablets. Device configuration via web pages is possible too. Web Sensors allow to user customize the design of web pages.History values memoryGraphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows to use graphs from thousands of devices. It is not a problem to show graphs on tablets or smartphones. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9.EmailWarning emails are sent when measured value exceed selected limits. Emails are also sent when values return back into safe range. SMTP authentication is supported, but SSL not. Emails with CSV file attachment can be sent at selected intervals.History export to CSVHistory values can be exported for further processing by the CSV file. CSV file can be processed inside spreadsheet application like Microsoft Excel or OpenOffice Calc. CSV file can be downloaded from web pages or periodically sent as email attachment.

ModbusTCP protocolModbus protocol for communication with SCADA systems or third party software. Devices use Modbus TCP protocol version. Two Modbus clients can be connected to the device at one moment. Actual values via XMLXML protocol for actual measured values reading. This protocol is suitable for Web Sensors integration into 3rd party SCADA systems.

SNMP protocolSNMP version 1 protocol for IT infrastructure. Using SNMP protocol you can read actual measured values, alarm sta-tuses and alarm parameters. Via SNMP protocol is also possible to get last 1000 measured values from the history table. MIB tables with OID description are available.

SNMP TrapSNMP Trap for IT infrastructure. Web Sensors allow sending Traps to selected Trap receiver server. Traps are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.

SOAP protocolWeb Sensors allow to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. Therefore it is not necessary to use port forwarding.

Syslog protocolSyslog protocol for IT infrastructure monitoring systems. Web Sensors allow sending text messages to selected Syslog server. Messages are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.

SNTP protocol - time synchronizationTime synchronisation with SNTP server. Actual time is shown at web pages and is necessary for timestamps inside CSV files. Synchronisation interval can be set to one day or to one hour.

Web Sensors with Ethernet connection are designed to measure current 4 - 20mA (0-20mA), tempe-rature, relative humidity, CO2 and barometric pressure of air in non-aggressive environments. Measu-red values are according to device type. Devices with relative humidity measurement can show one of computed values: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy. Temperature units are °C or °F.

The visual indication of the CO2 concentration is provided by three-colour LED.

Web Sensor of T-line is equipped with LCD display where current values can be displayed.

The device setup can be made by the TSensor software or web interface. TSensor software can be downloaded for free from the manufacturer’s website.

The latest version of firmware for your device with new features and even for older devices is available on the producer′s site www.cometsystem.cz/support/firmware-update.

Common parameters of Web Sensors Web interface for the device setup

Page 7: COMET measuring instruments katalog

5

Current measured values and sensor settings can be accessed directly through the web interface from your web browser. TSensor software, which is available on our website in the section Software, can be also used for setting the sensor.

Sensor settings can also be done directly in a web brow-ser in your PC, smartphone or tablet. All you need to do is enter the IP address of the sensor, open Settings and set up everything from communication to alarm e-mails.

Graphs of actual values can also be displayed through a Web browser. You can display up to one thousand measu-red values.

Current measured values are available on-line directly on a web browser from anywhere, all you need to do is enter the IP address. Alarms are indicated by a red field.

Common parameters of Web Sensors Web interface for the device setup

Minimum and maximum values together with a time stamp are recorded by the Web Sensor.

Page 8: COMET measuring instruments katalog

The Ethernet RJ45 connector for cable connection

Web Sensor t-line

Connector for power adapter with output

voltage 9-30 Vdc

Limits of LED indication may be changed by user.

Display for current measured values

Sensor models:

MEASURED VALUES without PoE* with PoE**

atmospheric pressure T2514

relative humidity + temperature T3510, T3511, T3511P T3610, T3611

relative humidity + temperature + atmospheric pressure T7510, T7511 T7610, T7611

temperature T0510, T4511 T0610, T4611

CO2 T5540, T5541

CO2+ relative humidity + temperature T6540

Sensor cover with filter fromstainless steel mesh. Filtering

ability is 0.025mm

Air intakes for CO2 measurement

External moun-ting holes for easy and fast mounting

without the need to take off lid cover

Case of sensor is made of ABS which is very resistant to mechanicaldamage.

RTD Pt1000 temperature sensor together with state-of-the-artcapacitive polymer sensor

0 to 1000 ppm

1000 to 1200 ppm

1200to 2000/10 000 ppm

* Please see page 8 - 9 for sensor specification ** Please see page 10 - 11 for sensor specification

Common parameters:

» measured values - temperature, relative humi- dity, atmospheric pressure, CO2, computed values» highly accurate and stable sensors» LCD display» traceable calibration certificate with traceability with EN ISO/IEC 17025

Page 9: COMET measuring instruments katalog

Low cost Web Sensor p-line

7

MEASURED VALUES without PoE* with PoE**

temperature P8510 P8610

temperature + relative humidity* P8511, P8541 P8631

0-20mA (4-20mA) P2520

Sensor models:

Case of sensor is made of ABS which is very resistant to mechanical damage.

External moun-ting holes for easy and fast mounting

without the need to take off lid cover

The Ethernet RJ45 connector for cable connection

* With the attached temperature and humidity probe ** Please see page 12 - 13 for sensor specification - type DSRH (max. length 15 metres)

Connector for power adapter with output

voltage 4.9V - 6.1 Vdc

» measured values - temperature, relative humi- dity, 0 - 20 mA (4 - 20 mA)» value for money» multi-channel version with the possibility of combining temperature and humidity probes» traceable calibration certificate with traceability with EN ISO/IEC 17025

Connectors for connection external temperature and

combinated temperature and humidity probes

Common parameters:

Page 10: COMET measuring instruments katalog

* custom range 10000 ppm for an extra fee

Device without PoE - connection procedure

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure Atm. pressureTemperature, relative

humidity, CO2

CO2

SENSOR MODEL T4511 T0510 T3510 T3511 T3511P T7510 T7511 T2514 T6540 T5540 T5541

temperature range -200 to +600°C -30 to +80°C -30 to +80°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -

accuracy ±0.2°C without temp. probe ±0.6°C ±0.6°C ±0.4°C ±0.4°C ±0.6°C ±0.4°C - ±0.6°C - -

relative humidity**

range - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - 0 to 100 %RH - -

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH - ±2.5 %RH - -

atm. pressure**

range - - - - - 600 to 1100 hPa 600 to 1100 hPa 600 to 1100 hPa - - -

accuracy - - - - - ±1.3 hPa ±1.3 hPa ±1.3 hPa - - -

C02***

range - - - - - - - - 0 to 2000 ppm* 0 to 2000 ppm* 0 to 10000 ppm

accuracy - - - - - - - - ± (50ppm+2% of measured value)

± (50ppm+2% of measured value)

± (110ppm+5% of measured value)

computed humidity values NO NO YES YES YES YES YES NO YES NO NO

supply voltage 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V

recommended calibration interval two years two years one year one year one year one year one year one year one year five years five years

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensor cover - - IP40 IP40 IP40 IP40 IP40 - IP40 - IP 65

temperature operating rangeof the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +80°C

temperature operating rangeof the measuring element - - -30 to +80°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -40 to +60°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 5 to 95 %RH 0 to 100 %RH

barometric pressure operatingrange - - - - up to 2,5MPa - - - 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position connectors upwards connectors upwards any position any position connectors upwards any position any position connectors upwards connectors upwards any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -40 to +60°C -40 to +60°C -40 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011

weight 145 g 145g 155 g 210 (250,330) g 260(300,380)g 155g 210 (250,330)g 130g 160g 140g 240 (270, 330)g

Web Sensor t-line without PoE and their specification

** accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C

Page 11: COMET measuring instruments katalog

9

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure Atm. pressureTemperature, relative

humidity, CO2

CO2

SENSOR MODEL T4511 T0510 T3510 T3511 T3511P T7510 T7511 T2514 T6540 T5540 T5541

temperature range -200 to +600°C -30 to +80°C -30 to +80°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -

accuracy ±0.2°C without temp. probe ±0.6°C ±0.6°C ±0.4°C ±0.4°C ±0.6°C ±0.4°C - ±0.6°C - -

relative humidity**

range - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - 0 to 100 %RH - -

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH - ±2.5 %RH - -

atm. pressure**

range - - - - - 600 to 1100 hPa 600 to 1100 hPa 600 to 1100 hPa - - -

accuracy - - - - - ±1.3 hPa ±1.3 hPa ±1.3 hPa - - -

C02***

range - - - - - - - - 0 to 2000 ppm* 0 to 2000 ppm* 0 to 10000 ppm

accuracy - - - - - - - - ± (50ppm+2% of measured value)

± (50ppm+2% of measured value)

± (110ppm+5% of measured value)

computed humidity values NO NO YES YES YES YES YES NO YES NO NO

supply voltage 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V

recommended calibration interval two years two years one year one year one year one year one year one year one year five years five years

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensor cover - - IP40 IP40 IP40 IP40 IP40 - IP40 - IP 65

temperature operating rangeof the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +80°C

temperature operating rangeof the measuring element - - -30 to +80°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -40 to +60°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 5 to 95 %RH 0 to 100 %RH

barometric pressure operatingrange - - - - up to 2,5MPa - - - 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position connectors upwards connectors upwards any position any position connectors upwards any position any position connectors upwards connectors upwards any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -40 to +60°C -40 to +60°C -40 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011

weight 145 g 145g 155 g 210 (250,330) g 260(300,380)g 155g 210 (250,330)g 130g 160g 140g 240 (270, 330)g

Web Sensor t-line without PoE and their specification

** accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C *** accuracy of CO2 concetration of measurement at 25°C and 1013 hPa

Computed values

Absolute humidity Accuracy: ±3 g/m3 at ambienttemperature T < 25 °Cfor more details see manualRange: 0 to 400 g/m3

Dew point temperatureAccuracy: ±1.5°C at ambient temperatureT<25°C and relative humidity RH >30%, for more details see manualRange: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2.1 g/kg at ambienttemperature T < 35 °CRange: 0 to 550 g/kg

Specific enthalpyAccuracy: ± 4kJ/kg at ambienttemperature T < 25 °CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2.2 g/kg at ambienttemperature T < 35 °CRange: 0 to 995 g/kg

Page 12: COMET measuring instruments katalog

Device with PoE - connection procedure

Connector for power adapter with output voltage 4.9 - 6.1 Vdc

Case of sensor is made of ABS which is very resistant to mechanicaldamage.

Sensor cover with filter fromstainless steel mesh. Filteringability is 0.025mm

The Ethernet RJ45 connector for cable connection. Where power over Ethernet is used, the network infra-structure must be compatible with IEEE 802.3af standard.

Display for current measured values

Mounting holes for mounting the unit on

the wall

RTD Pt1000 temperature sen-sor together with state-of-the-art capacitive polymer sensor

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure

SENSOR MODEL T4611 T0610 T3610 T3611 T7610 T7611

temperaturerange -200 to +600°C -20 to +60°C -20 to +60°C -30 to +105°C -20 to +60°C -30 to +105°C

accuracy ±0.2°C without temperature probe ±0.6°C ±0.6°C ±0.4°C ±0.6°C ±0.4°C

relative humidity*

range - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH

atm. pressure*range - - - - 600 to 1100 hPa 600 to 1100 hPa

accuracy - - - - ±1.3 hPa ±1.3 hPa

computed humidity values NO NO YES YES YES YES

supply voltage 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V

Power over Ethernet (PoE)according to IEEE 802.3af YES YES YES YES YES YES

recommended calibration interval two years two years one year one year one year one year

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensor cover - - IP40 IP40 IP40 IP40

temperature operating rangeof the case with electronics -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C

temperature operating rangeof the measuring element - - -20 to +60°C -30 to +105°C -20 to +60°C -30 to +105°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

mounting position any position connectors upwards connectors upwards any position connectors upwards any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility

EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1,EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1,EN 55011

weight 310g 310 320g 380 (420,500) g 320g 380 (420,500) g

Web Sensor t-line with PoE and their specification

» Power over Ethernet (PoE) according to IEEE 802.3af» measured values - temperature, relative humidity, atmospheric pressure, computed values» highly accurate and stable sensors» traceable calibration certificate with traceability with EN ISO/IEC 17025

* accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C

Common parameters:

Page 13: COMET measuring instruments katalog

11

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure

SENSOR MODEL T4611 T0610 T3610 T3611 T7610 T7611

temperaturerange -200 to +600°C -20 to +60°C -20 to +60°C -30 to +105°C -20 to +60°C -30 to +105°C

accuracy ±0.2°C without temperature probe ±0.6°C ±0.6°C ±0.4°C ±0.6°C ±0.4°C

relative humidity*

range - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH

atm. pressure*range - - - - 600 to 1100 hPa 600 to 1100 hPa

accuracy - - - - ±1.3 hPa ±1.3 hPa

computed humidity values NO NO YES YES YES YES

supply voltage 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V

Power over Ethernet (PoE)according to IEEE 802.3af YES YES YES YES YES YES

recommended calibration interval two years two years one year one year one year one year

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensor cover - - IP40 IP40 IP40 IP40

temperature operating rangeof the case with electronics -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C -20 to +60°C

temperature operating rangeof the measuring element - - -20 to +60°C -30 to +105°C -20 to +60°C -30 to +105°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

mounting position any position connectors upwards connectors upwards any position connectors upwards any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility

EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1,EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1,EN 55011

weight 310g 310 320g 380 (420,500) g 320g 380 (420,500) g

Web Sensor t-line with PoE and their specification

* accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C

Computed values

Absolute humidity Accuracy: ±3 g/m3 at ambienttemperature T < 25 °Cfor more details see manualRange: 0 to 400 g/m3

Dew point temperatureAccuracy: ±1.5°C at ambient temperatureT<25°C and relative humidity RH >30%, for more details see manualRange: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2.1 g/kg at ambienttemperature T < 35 °CRange: 0 to 550 g/kg

Specific enthalpyAccuracy: ± 4kJ/kg at ambienttemperature T < 25 °CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2.2 g/kg at ambienttemperature T < 35 °CRange: 0 to 995 g/kg

Page 14: COMET measuring instruments katalog

Measured values Temperature Temperature, relative humidity Current - mA

SENSOR MODEL P8510 P8610 P8511 P8631 P8541 P2520

temperature

range -30 to +80°C -20 to +60°C according to the used probe*

according to the used probe*

according to the used probe* -

accuracy±0.8°C above -10°C

±0.8°C above -10°C

according to the used probe*

according to the used probe*

according to the used probe* -

±2°C below -10°C ±2°C below -10°C - - - -

relative humidity range - - according to the

used probe*according to the used probe*

according to the used probe* -

accuracy - - according to the used probe*

according to the used probe*

according to the used probe* -

current measuring range - - - - - 0-25mA(max. 30mA)

accuracy of current measurement - - - - -

± 0.1% FS from 0°C to +50°C

± 0.3% FS from -30°C to +80°C

resolution 0.1°C 0.1°C 0.1°C, 0.1%RH 0.1°C, 0.1%RH 0.1°C, 0.1%RH 1uA

input impedance - - - - - 20Ω

supply voltage 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 9-30 V

Power over Ethernet (PoE)according to IEEE 802.3af - - - -

recommended calibration interval two years two years according to the

used probe*according to the used probe*

according to the used probe* two years

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30

temperature operating rangeof the case with electronics -30 to +80°C -20 to +60°C -30 to +80°C -20 to +60°C -30 to +80°C -30 to +80°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

mounting position cover downward cover downward any position any position any position cover downward

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility EN 61326-1 EN 60950-1 EN 61326-1 EN 60950-1 EN 61326-1 EN 61326-1

weight 130g 145g 125g 140g 135g 150g

Web Sensor p-line and their specification

P2520 two channel current loop converter is designed to connect sensors with output 4-20mA / 0-20 mA into Ethernet network. The current signal can be recalculated to physical values measured by the connected sensors. Sensors can be powered directly from the P2520 converter.

» Measured values can be read by means of Ethernet connection.» The instrument may also send a warning message if the measured value exceeds adjusted limit. » The device setup can be made by the www interface.

One channel device for external probes

Three-channel device for external probes

Four-channel device for external probes

Page 15: COMET measuring instruments katalog

Measured values Temperature Temperature, relative humidity Current - mA

SENSOR MODEL P8510 P8610 P8511 P8631 P8541 P2520

temperature

range -30 to +80°C -20 to +60°C according to the used probe*

according to the used probe*

according to the used probe* -

accuracy±0.8°C above -10°C

±0.8°C above -10°C

according to the used probe*

according to the used probe*

according to the used probe* -

±2°C below -10°C ±2°C below -10°C - - - -

relative humidity range - - according to the

used probe*according to the used probe*

according to the used probe* -

accuracy - - according to the used probe*

according to the used probe*

according to the used probe* -

current measuring range - - - - - 0-25mA(max. 30mA)

accuracy of current measurement - - - - -

± 0.1% FS from 0°C to +50°C

± 0.3% FS from -30°C to +80°C

resolution 0.1°C 0.1°C 0.1°C, 0.1%RH 0.1°C, 0.1%RH 0.1°C, 0.1%RH 1uA

input impedance - - - - - 20Ω

supply voltage 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 4.9 - 6.1V 9-30 V

Power over Ethernet (PoE)according to IEEE 802.3af - - - -

recommended calibration interval two years two years according to the

used probe*according to the used probe*

according to the used probe* two years

protection class of the case with electronics IP30 IP30 IP30 IP30 IP30 IP30

temperature operating rangeof the case with electronics -30 to +80°C -20 to +60°C -30 to +80°C -20 to +60°C -30 to +80°C -30 to +80°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

mounting position cover downward cover downward any position any position any position cover downward

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility EN 61326-1 EN 60950-1 EN 61326-1 EN 60950-1 EN 61326-1 EN 61326-1

weight 130g 145g 125g 140g 135g 150g

13

External probes DSTG8/C DSTGL40/C DSTR162/C DSRH

temperature

range -50 to +100°C -30 to +80°C -30 to +80°C 0 to +50°C

accuracy±0.5°C from -10 to +80°C

±0.5°C from-10 to +80°C

±0.5°C from -10 to +80°C ±2°C

otherwise ±2°C otherwise ±2°C otherwise ±2°C

relative humidity

range - - - 0 to 100%RH

Accuracy of Relative humidity (10% – 90% RH) at 25°C

- - - ±3.5% RH

recommended calibration interval two years two years two years one year

IP class of case with electronics IP67 IP67 IP67 IP40

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH

mounting position any position any position any position any position

sensor dimensions (diameter x length) 5.7 x 40mm 5.7 x 40mm 10 x 25mm 18 x 88mm

The maximum sum of the lengths of all probes is 40m.

Mu l t i - c hanne l unit allows the combination of several humidity and temperature probes.

Device without PoE - connection procedure

Device with PoE - connection procedure

Web Sensor p-line and their specification

signal input 0 - 20 mA

power supply

signal output0 - 20 mA

P2520

Page 16: COMET measuring instruments katalog

Releay outputsTwo relay output for alarming or external device control. It is possible to assign any input value to each relay. Relay can be remotely controlled using ModbusTCP communication protocol.

Binary inputsIt is possible to read three binary inputs statuses for detection of two-state events - e.g. smoke, water leak detectors, door contact. Supported binary inputs: dry contact, open collector or two-state voltage signal.

Acoustic alarmsAcoustic signalisation can be activated after exceeding set limits. Alarm can be confirmed (deactivated) from the device keyboard.

WWW serverCurrent values are available via embedded web server. Design of the web pages can be changed according to user requirements.

EmailWarning emails are sent when measured value exceed selected limits. SMTP authentication is supported, but SSL not.

History export to CSVHistory values can be exported for next processing by the CSV file. CSV file can be processed inside spreadsheet ap-plication like Microsoft Excel or OpenOffice Calc.

ModbusTCP protocolModbus protocol for communication with SCADA systems or third party software. Device use version of Modbus TCP protocol.

SNMP protocolSNMP version 1 protocol for IT infrastructure. Using SNMP protocol you can read actual measured values, alarm statuses and alarm parameters. MIB tables with OID description are available.

SNMP TrapSNMP Trap for IT infrastructure. The device allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm on channel or at error states.

SOAP protocolThe device allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. Therefore it is not necessary to use port forwarding.Syslog protocolSyslog protocol for IT infrastructure monitoring systems. The device allows sending text messages to selected Syslog server. Messages are sent in case of alarm on channel or at error states.

SNTP protocol - time synchronizationTime synchronisation with SNTP server. Actual time is shown at web pages and is necessary for timestamps inside CSV files.

Programmable regulators with Ethernet connection are designed to measure temperature and relative hu-midity of air, to measure concentration of CO2 in the air, to signal alarms and control external devices. Re-gulators can be used in a chemically non-aggressive environment. Measured values are according to device type. Devices with relative humidity measurement can show one of computed values: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy. Temperature units are °C or °F. The CO2 concentration is measured using the maintenance free sensor. The unique patented auto-calibration procedure compensates ageing of the measuring element and guarantees outstanding high reliability and long-term stability. The sensors are equipped with two relay outputs for alarm indication or control of external devices. Each relay can be assigned to any input value, set up the comparing limit, delay, hysteresis and audible alarm. As an option you can remotely change its status via Modbus communication protocol. Sensors are also equipped with three binary inputs for detection of two-state signals, e.g. flood detection, smoke detection, door con-tacts and so on.

The device can be used to check measured values. In case of going over the limits set up by the user it can send a warning message to the user’s chosen destination.

The device is internally divided into two blocks, the first one takes care of measuring and output relays. It is possible to set up these parameters directly from the keyboard or from the free to download program TSen-sor. This software can be downloaded from www.cometsystem.cz The second block will ensure all Ethernet services. Its configuration can be done by the help of TELNET software or from the free to download program TSensor. Warning, this set up cannot be changed by the device’s own keyboard.

Common parameters of sensors with Ethernet and relay outputs

Page 17: COMET measuring instruments katalog

15

Common parameters of sensors with Ethernet and relay outputs

Electrical wiring of HxxxxR

Electrical wiring of Hxxxx

Applications

smoke detector

flood detector

door contact

motion detector

Page 18: COMET measuring instruments katalog

Glands for the cable to the output relay

Two relays for alarm indication or control of external devices. Each relay can be assigned to any the measured value. The relay can also be controlled remotely via the com-munication protocol ModbusTCP

The lid cover of device with keypad for control

Sensor cover with filter fromstainless steel mesh. Filteringability is 0,025mm

Sensor models:

MEASURED VALUES unit designation*

temperature + 3 binary inputs H0530, H4531

temperature + relative humidity + 3 binary inputs H3530, H3531, H3531P

temperature + relative humidity + atm. pressure + 3 binary inputs H7530, H7531

CO2 H5521, H5524

CO2 + relative humidity + temperature H6520

Mounting holes for mounting the unit on the wall

RTD Pt1000 temperature sensor together with

state-of-the-art capacitive polymer sensor

Air intakes for CO2 measurement

0 to 1000 ppm

1000 to 1200 ppm

1200to 2000/10 000 ppm

Ethernet RJ45 connector for cable connection

Connector for power adapter with output voltage 9-30 Vdc

* Please see page 18 - 19 for sensor specification

Sensors of temperature, relative humidity, atm. pressure, CO2 with Ethernet and relay outputs

» interior design of device for wall mounting» measured values - temperature, relative humidity, atmospheric pressure, CO2, computed values» traceable calibration certificate with traceability with EN ISO/IEC 17025

Common parameters:

Limits of LED indica-tion may be changed by user

CO2 module

Page 19: COMET measuring instruments katalog

17

Sensors of temperature, relative humidity, atm. pressure, CO2 with Ethernet and relay outputs

Sensor models:

MEASURED VALUES unit designation*

temperature + 3 binary inputs H4531R

temperature + relative humidity + 3 binary inputs H3531R

temperature + relative humidity + atm. pressure + 3 binary inputs H7531R

terminals for input and output signal

...into 19„rack

* Please see page 19 for sensor specification

Ethernet RJ45 connector for cable connection

Connector for power adapter with output

voltage 9-30 Vdc

» designed for 19″ rack mounting» measured values - temperature, relative humi- dity, atmospheric pressure, computed values» traceable calibration certificate with traceability with EN ISO/IEC 17025

Common parameters:

Visualization of binary inputs is done by three LED diodes. Each relay status is indicated with other two LED diodes described as ALARM1 and ALARM2 shown also on LCD.

Display with keypad for setting

RTD Pt1000 temperature sensor together with

state-of-the-artcapacitive polymer sensor

Mounting brackets to rack 19″

Glands for cables

Page 20: COMET measuring instruments katalog

* za příplatek lze změnit u přístroje s integrovaným CO2 rozsah na 0 až 10 000ppm ± (110ppm+5% z měřené hodnoty)

Computed values

Connection via PoE adapterElectrical wiring

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure

Temperature, relative

humidity, CO2

CO2

TemperatureTemperature,

relative humidity

Temperature, relative humidi-ty, atm. pressure

SENSOR MODEL H4531 H0530 H3530 H3531 H3531P H7530 H7531 H6520 H5524 H5521 H4531R H3531R H7531R

temperature

range -200 to +600°C -30 to +80°C -30 to +80°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - - -200 to

+600°C -30 to +105°C -30 to +105°C

accuracy±0.2°C without temp. probe

±0.4°C ±0.4°C ±0.4°C ±0.4°C ±0.4°C ±0.4°C - -±0,2°C without temperature probe

±0.4°C ±0.4°C

relative humidity**range - - 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH - - - 0 to 100%RH 0 to 100%RH

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH - - - ±2.5 %RH ±2.5 %RH

atmospheric pressure**range - - - - 600 to 1100

hPa600 to 1100 hPa - - - - - 600 to

1100 hPa

accuracy - - - - ±1.3 hPa ±1.3 hPa - - - - - ±1.3 hPa

C02 ***

range - - - - - - 0 to 2000 ppm 0 to 2000 ppm 0 to 10 000 ppm - - -

accuracy - - - - - - ± (50ppm+2% of measured value)

± (110ppm+5% of mea-sured value)

- - -

relay output max. switching voltage, current, power 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA

computed humidity values NO NO YES YES YES YES YES NO NO NO YES YES

supply voltage 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V

recommended calibration interval two years two years one year one year one year one year one year five years five years two years one year one year

protection class of the case with electronics IP40 IP40 IP40 IP40 IP40 IP40 IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensorcover - - IP40 IP40 IP40 IP40 IP40 - IP65 - IP40 IP40

temperature operating rangeof the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

temperature operating rangeof the measuring element - - -30 to +80°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - -40 to +60°C - -30 to +105°C -30 to +105°C

humidity operating range without con-densation 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 až 100%RH 0 to 100%RH 0 to 100%RH 0 to 95%RH 5 to 95 %RH 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH

barometric pressure operatingrange - - - - up to 2.5MPa - - 850 to

1100hPa850 to 1100hPa

850 to 1100hPa - - -

mounting position any position cover downwards

cover downwards any position cover

downwards any position cover downwards

connectors upwards any position any position any position any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -40 to +60°C -40 to +60°C -40 to +60°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011 EN 61326-1 EN 61326-1 EN 61326-1

weight 340g 340g 360g 410(450,530)g 460(500,580)g 360g 410(450,530)g 350g 330g 420 (450, 510)g 1025g 1090g 1090

(1130,1210)g

Sensors with Ethernet and relay outputs and their specification

** accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C * Custom range 10000 ppm for an extra fee

Specific humidityAccuracy: ±2.1 g/kg at ambienttemperature T < 35 °CRange: 0 to 550 g/kg

Page 21: COMET measuring instruments katalog

19

Measured values Temperature Temperature, relative humidity Temperature, relative humidity, atm. pressure

Temperature, relative

humidity, CO2

CO2

TemperatureTemperature,

relative humidity

Temperature, relative humidi-ty, atm. pressure

SENSOR MODEL H4531 H0530 H3530 H3531 H3531P H7530 H7531 H6520 H5524 H5521 H4531R H3531R H7531R

temperature

range -200 to +600°C -30 to +80°C -30 to +80°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - - -200 to

+600°C -30 to +105°C -30 to +105°C

accuracy±0.2°C without temp. probe

±0.4°C ±0.4°C ±0.4°C ±0.4°C ±0.4°C ±0.4°C - -±0,2°C without temperature probe

±0.4°C ±0.4°C

relative humidity**range - - 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH - - - 0 to 100%RH 0 to 100%RH

accuracy - - ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH ±2.5 %RH - - - ±2.5 %RH ±2.5 %RH

atmospheric pressure**range - - - - 600 to 1100

hPa600 to 1100 hPa - - - - - 600 to

1100 hPa

accuracy - - - - ±1.3 hPa ±1.3 hPa - - - - - ±1.3 hPa

C02 ***

range - - - - - - 0 to 2000 ppm 0 to 2000 ppm 0 to 10 000 ppm - - -

accuracy - - - - - - ± (50ppm+2% of measured value)

± (110ppm+5% of mea-sured value)

- - -

relay output max. switching voltage, current, power 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA 50V, 2A, 60VA

computed humidity values NO NO YES YES YES YES YES NO NO NO YES YES

supply voltage 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V 9-30 V

recommended calibration interval two years two years one year one year one year one year one year five years five years two years one year one year

protection class of the case with electronics IP40 IP40 IP40 IP40 IP40 IP40 IP30 IP30 IP30 IP30 IP30 IP30

protection class of the sensorcover - - IP40 IP40 IP40 IP40 IP40 - IP65 - IP40 IP40

temperature operating rangeof the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

temperature operating rangeof the measuring element - - -30 to +80°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - -40 to +60°C - -30 to +105°C -30 to +105°C

humidity operating range without con-densation 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 až 100%RH 0 to 100%RH 0 to 100%RH 0 to 95%RH 5 to 95 %RH 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH

barometric pressure operatingrange - - - - up to 2.5MPa - - 850 to

1100hPa850 to 1100hPa

850 to 1100hPa - - -

mounting position any position cover downwards

cover downwards any position cover

downwards any position cover downwards

connectors upwards any position any position any position any position

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -40 to +60°C -40 to +60°C -40 to +60°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1, EN 55011

EN 61326-1, EN 55011

EN 61326-1, EN 55011 EN 61326-1 EN 61326-1 EN 61326-1

weight 340g 340g 360g 410(450,530)g 460(500,580)g 360g 410(450,530)g 350g 330g 420 (450, 510)g 1025g 1090g 1090

(1130,1210)g

Sensors with Ethernet and relay outputs and their specification

** accuracy of relative humidity in range 5% to 95% and of atmospheric pressure at 23°C *** accuracy of CO2 concetration of measurement at 25°C and 1013 hPa

Absolute humidity Accuracy: ±1.5 g/m3 at ambienttemperature T < 25 °Cfor more details see manualRange: 0 to 400 g/m3

Dew point temperatureAccuracy: ±1.5°C at ambient temperatureT<25°C and relative humidity RH >30%, for more details see manualRange: -60 to +80 °C (-76 to 176 °F)

Specific enthalpyAccuracy: ± 3kJ/kg at ambienttemperature T < 25 °CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2 g/kg at ambienttemperature T < 35 °CRange: 0 to 995 g/kg

Page 22: COMET measuring instruments katalog

SA200A Magnetic door contact for detecting opening / closing windows, doors and so on.

LD-12Water leakage detector.

SD-280 Optical smoke detector.

SP008AC voltage presence sensor.

Optional accessories

Detectors

PP90 – Right-angled stainless steelflange.

PP4 – plastic flat circular flange

SP004 - Plastic gland for directmounting of the humidity probeto a 29 mm diameter hole.

The probe for measuring the moisture of compressed air should be pla-ced directly on the pressure pipelines to achieve higher measurement accuracy and faster response times. But there are cases where such placement is not possible. The reason is the high air speed, high tempe-rature, high pollution, small diameter pipes, etc. Such situation can be solved by placing the probe into the flow measuring chamber.

SH-PP - Flow chamber for compres-sed air measurement up to 25 bars - stainless steel DIN 1.4301 inlet and outlet connection - G1/8 thread humidity probe connection - G1/2 thread screw-coupling not included.

1 ... sampling2 ... closing valve3 ... probe4 ... flow chamber SH-PP5 ... closing valve6 ... outlet tube

MP047Universal holder for probes for easy mounting to rack 19″.

MP046Universal holder for P8xxx and Tx5xx Web Sensors for easy mounting to rack 19″.

Mounting accessories

JS-20 - P.I.R. motion detector is for interior protection. It detects object movement having human body temperature. The signal from the sensor is electronically analyzed. This ensures that the detector provides excellent sensitivity and false alarms are basically eliminated.

F8000 - Solar radiation shield for transmitters with T+RH probe on a cable.

F5300 - Teflon (PTFE) sensor cover (white colour), with increased resistan-ce against splashing water, non-absorbent surface, does not rust. Porous size 25μm.Temperature range -40°C to +125°C.

Protection of sensors

F5200 - Grey sensor cover with filter from stainless steel mesh, filtering abili-ty 0.025mm.F5200B - Black sensor cover with filter from stainless steel mesh, filtering ability 0.025mm.

F0000 - Sintered bronze sensor cover. Filtering ability 0.025mm.

Page 23: COMET measuring instruments katalog

21

KIT-GSM-W - If GSM modem is connected to your computer or server where Comet database is installed then you get the 24-hour surveillance of critical events. This inexpensive service can prevent costly damage to health, goods and property.

TP-LINK-TLWi-Fi adapter for wireless connection of transmitter or data logger to Ethernet network. Including replaceable antenna and power adapter. Long term proved operation.

LAN LAN LAN

Client

LAN LAN

Router

Client

TL-POE - Power over Ethernet (PoE) splitter for connection of sensors and Web Sensors which does not support PoE.

PoE switch IEEE 802.3af compatible

CAT5 UTP cable(Power & Data) PoE splitter

TL-POE10R

Power Cable(+12 V)

T3510

A1825Switching power supply unit for Web Sensors P8xxx and Tx6xx.

A1515Switching power supply unit for Ethernet transmit-ters Tx5xx, Hx5xx.

HM024 - Set of humidity standards 80% RH with 5 application pads.

Calibration

Power supplies

Communication

MD046 - Vessel for adjustment andcalibration of humidity.

HM023 - Set of humidity standards 10% RH with 5 application pads.

Page 24: COMET measuring instruments katalog

For users of Web Sensors a solution for data collection to one central database is available. It is based on MS SQL or MySQL. Software system is suitable for users who want to analyze data from multiple loggers MS or other products of Comet System.

Comet Database offers:• data stored in one place and accessible with Comet Database Viewer• to provide data in table and graph• to print and export data• alarms via SMS texts and emails• acoustic and visual signalization of alarms• compatibility with all Comet System devices and 3rd party devices • displaying of online values

If you already have Comet database there is no need to purchase any additional software for running your Web Sensors with Comet Database.

Comet Database also exist in 30 days trial version. So you can test it without any worries.

TSensorFree configuration software for sensors with Ethernet output.

SensorReaderFreeware software for displaying and logging data from one COMET sensor. The software stores measured values to a CSV file which can be processed in MS Excel. The software allows acoustic signalization of exceeded limits or sen-sor failure.

Comet Database - Monitoring of temperature, relative humidity, atmospheric pressure and CO2 by means of Ethernet

Page 25: COMET measuring instruments katalog

23

What does Comet Database offer?

» 24 hours supervision » storage place for your data» simple and clear access to your measured values» storage place for all Comet System devices» alarm SMS texts and e-mails

Comet Database ViewerEach purchased Comet Database already contains one licence of Database Viewer. This low cost browser enables several clients to view database from different places on internal network or internet. Other viewer licences can be purchased separately for other users of Comet Database.

Comet Database - Monitoring of temperature, relative humidity, atmospheric pressure and CO2 by means of Ethernet

Page 26: COMET measuring instruments katalog

• Universal 1-16 channel monitoring systems • Online monitoring

• Create alarm conditions • Recording • Regulation and control of processes

• Monitoring of temperature, humidity, CO2 and other analog and and two-state values

Traceable calibration certificate from the manufacturer with traceability in accordance with EN ISO/IEC 17025

Page 27: COMET measuring instruments katalog
Page 28: COMET measuring instruments katalog

Device enables: • to measure and process 1 to 16 input signals • to acquire autonomous time record of measured values • create alarm states • to perform other actions based on created alarms (audible, visual indication, controlling of relay outputs, sending SMS message, controlling of telephone dialer, sending of messages via several protocols of the Ethernet interface etc.) • to monitor on-line measured values and states

Features:• Monitoring system MS contains up to 16 inputs » MS6D:16 universal software programmable inputs, see page 8 » MS55D: modular 1 - 16 inputs, wide range of moduls on the page 9 • Memory for 480 000 readings, automatic data download is possible • Logging interval from 1 sec to 24 hours, for each channel individually selectable • Various recording options• High system accuracy• A virtual (calculated) channels on unused inputs• Indication of alarms states

Monitoring Systems MS

Control panel

Control keyboard

Low and high alarm indicator per channel

Data loggers are designed for measurement, record, evaluation and consequent processing of input electrical signals, characterized by relatively slow changes (>1s). Together with proper transmitters and transducers are suitable for moni-toring of physical values.

Full memory indication

Indication of presenceof power voltage

Two-line LCD display with channel name and current measurement

Page 29: COMET measuring instruments katalog

Top view (communication interface)

RS232, RS485 and USB outputs. Ethernet output interface is optional.

Bottom view (sensor connections)

The table below shows the characteristic differences between the systems. The Monitoring System MS55D uses hardware modules, while MS6D, MS6R or MS6-Rack is equipped with 16 universal, software configurable inputs.

Měřící a záznamový systém MS v různých provedeních

Each Monitoring System contains 16 software configurable inputs. See them on the page 8.

main differences MS6D MS55D

inputs 16 software pro-grammable inputs

1 - 16 hardware input modules

maximum measured DC current 20 mA dc 5 A dc

maximum measured DC voltage 10 V dc 75 V dc

most sensitive measuring range of dc voltage 18 mV dc 100 mV dc

maximum measured AC current - 5 A ac

maximum measured AC voltage - 50 V ac

input for measurement of frequency - 0 to 5 kHz

input for counting of pulses - Yes

MS55D

MS55D

3

Monitoring Systems MS - models and variations

The user can select the hardware modules to be fitted into the monitoring system MS. See the page 9.

MS6D and its variations

MS6D

MS6-Rack - For mounting to 19“ rack

MS6R - MS6R - For deskopt use

power voltage 12Vdc/24Vdc switch to power connected sensors

Page 30: COMET measuring instruments katalog

Recording and online monitoring of temperature and humidity, leaks and smoke in data centers

and server rooms.

Building and energy manage-ment. Complete temperature,

humidity, pressure and CO2 monitoring. Recording of

energy consumption.

Recording of, inter alia, pulse signals, pressures, temperatures, voltages and flows.

The registration and monitoring of processes, the registration of various parameters in test facilities.

Registration of temperatures, carbon dioxide (CO2) and other critical parameters in the context of GLP or GMP regulations.

Comet logger may be used in a wide range of applications, in clean and sterile environ-ment as well as in the contaminated indu-strial environments. There is also the out-door solution together with the watertight case. Below is an overview of some common applications.

Food industry and supermarkets.

Registration and monitoring critical temperature with respect to HACCP

regulations.

Recorded values are stored to a non volatile electronic memory and may be supplemented by the accompanying text - pro-cesses. Various options for data recording can be set up.

Application

Recording

Various options for data recordingIn addition to continuous recording mode with a constant interval can also enjoy a variety of other options. You can record data with its own interval only when certain conditions are valid, which may depend on measured values , time or direct user intervention. For example, you can control recording via an external contact or it is possible to set faster sampling mode during alarm conditions.

ProcessesProcess is the name of action recorded by data logger in time. User of data logger can enter from its keyboard to each input channel (except bi-nary inputs) different previously preset names of processes and such way to distinguish in record, which action was performed at that time.

In case of power failure In the event of a power failure, the backed up datalogger will continue to measure. Recorded data contains date and time of power failure. If the data logger is connected to GSM modem, the operator is immediately aware of difficulties.

Page 31: COMET measuring instruments katalog

Measuring and recording system MS has been developed to meet all require-ments for the possibility of alarming. Each of the 16 channels offers setting of hysteresis, a delay and up to four conditions to active alarm. Alarm can be pre-sented as sound (buzzer) and as visual signal (LED 1-32). For each alarm you can assign actions to be performed.

Communication through GSM modem, GPRS / EDGE routerModems can be used to set up a monitoring system MS, reading the recorded data, reading the current values and to communicate via SMS messages. The offered modems have been thoroughly tested to ensure maximum reliability.

Alerts via:

» Integrated buzzer» External siren or lights» Email messages» SMS texts via connected GPRS modem or router» Telephone dialer

Alerts via SMS textsAll data loggers are equipped with RS232 interface. GSM modem (GPRS router)can be connected to that port for transmitting alarm SMS texts. Up to four phone numbers can be set. Using text messages can also read the current values .

Maximum connectable voltage on relay and current

1A/24Vac

Output signal 0V/4.8Vmax. current 50 mA

Alarms and Communication interfaces

USB

GSM/Wi-Fi (accessories)

RS-232/485

Ethernet (optional)

Communication interfaces

Relay onMonitoring system MS activates selected relays (integrated relay ALARM OUT or external relays module) depending on alarm states.You can combine up to 16 switching external relay depending on arisen conditions. One of these conditions can be controlled via SMS messages.

Relays module (accessories)

Output ALARM OUT

Email messages Because of Ethernet interface you can expand communication possibi-lities of measuring system MS. Then alarm emails are sent directly to your email inbox.You can also read the current data via web browser.

5

Page 32: COMET measuring instruments katalog

Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible. The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network.

Common connectivity options

Page 33: COMET measuring instruments katalog

In the event that the number of 16 channels is insufficient, then it is possible to connect several units among themselves via RS485 or via the Ethernet network. A unique RS485 or IP address is assigned to each unit. However the distance between data loggers MS connected together via RS485 should not exceed 1200 meters.

» maximum length of the entire cabling is 1200m and maximum 32 data loggers can be connected» maximum communication speed of 115200Bd (download of full memory in 4min 30s)» communication takes place through the software for data logger

» download of memory in 2min 30s (depends on the network throughput)» communication and sending alarm messages by means of several network protocols is enabled (web, SNMP, SMTP, SysLog, SOAP, ModBus) » each data logger has its IP address (support DHCP)

RS485/RS232

RS485/Ethernet

more on the page 14

If you need more than 16 input channels

Ethernet

RS485/USB

7

Page 34: COMET measuring instruments katalog

Each Monitoring System contains 16 software configurable inputs from user PC. Also signals from sensors working on RS485 bus with ModBus or Advantech protocol can be recorded. RS485 input is available as optional accessory.

Note: The inputs are not galvanically isolated (except RS485 input). If you need galvanically isolated inputs then you can choose from a wide range of input modules for monitoring system MS55D. FS means (full scale) and MV (measured value).

Measured values Range Accuracy Note

curr

ent

DC 4 to 20 mA ±0.1% FS (±0.02 mA)it is possible to connect pasive sensors (powered by monito-ring system) or active sensor with its own power supply. Input resistance about 110 Ohms.

volt

age

DC

-10 V to+10 V ±0.1% FS (±10 mV)

Input resistance about 10 MOhms-1 V to +1 V ±0.1% FS (±1 mV)

-100 mV to +100 mV ±0.1% FS (±100 uV)

-18 mV to +18 mV ±0,1% FS (±18 uV)

res

ista

nce

two-wire resistance measurement

0 to 300 Ohms ±0.1% FS (±0.3 Ohms) measuring current approximately 0.8 mA @ 50 ms pulse

0 to 3000 Ohms ±0.1% FS (±3 Ohms) measuring voltage approximately 0.5 mA @ 50 ms pulse

0 to 10000 Ohms

±0.1% FS (±10 Ohms) measuring current approximately 0.1 mA @ 50 ms pulse

tem

per

atu

re p

rob

es

Pt

and

Ni

Ni1000 -50 °C to +250 °C±0.2 °C (-50 °C to 100 °C) Ni1000/6180 ppm, two-wire connection

±0.2 % MV (100 °C to 250 °C) measuring current approximately 0.5 mA @ 50 ms pulse

Pt100 -200 °C to +600 °C±0.2 °C (-200 °C to+100 °C) Pt100/3850 ppm, two-wire connection

±0.2 % MV (+100 °C to +600 °C) measuring current approximately 0.8 mA @ 50 ms pulse

Pt1000 -200 °C to +600 °C±0.2 °C (-200 °C to+100 °C) Pt1000/3850 ppm, two-wire connection

±0.2 % MV (+100 °C to +600 °C) measuring current about 0.5 mA @ 50 ms pulse

ther

moc

oup

le

K (NiCr-Ni) -200 °C to 1300 °C

±(0.3 % MV +1.5 °C) MS6D only linearized, with cold junction compensation, datalogger must be placed in recommendend working position

T (Cu-CuNi) -200 °C to 400 °C

J (Fe-Co) -200 °C to 750 °C

S (Pt10 % Rh-Pt) 0 to 1700 °C

N (NiCrSi-NiSiMg) -200 °C to 1300 °C

B (Pt30 % Rh-Pt) 100 °C to 1800 °C ±(0.3 % MV +1.0 °C)in range 300 °C to 1800 °C linearized, without cold junction compensation

ther

mis

tor

NTC with selectable formula

up to maximum thermistor resistance 11000 Ohms

according to the used resistancerange (see measurement of resistance)

the same characteristics for all connected thermistors

default settings: R25=2252 Ohms, R80 = 282.7 Ohms

bin

ary

sig

nal

potential-less contact

binary signal

input voltage for state „L“ (IN-COM) < 0.8 V

input voltage for state „H“ (IN-COM) > 2 V

open collector resistance of closed contact for state „L“ (IN-COM) < 1 kOhms

voltage levels

resistance of open contact for state „H“ (IN-COM) > 10 kOhms“

minimum duration for sensing of change: 200 ms

RS

48

5

input for serial signal RS485 on request

input serves for reading from devices supporting protocol Mod-Bus RTU or Advantech

connected to terminals next to terminals for channel 15 and 16

input can work with 16 devices

galvanically isolated

Parameters of conf gurable inputs MS6D

Page 35: COMET measuring instruments katalog

9

The user can select the hardware modules to be fitted into the monitoring system MS. The modular design gives you the freedom to start with several input modules and to expand the system later on.

Measured valuesMo-dule types

Range Accuracy Notes

curr

ent

DC

A0 4 to 20 mA

±0.1 % FS

with source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet).

only galvanic not isolated

A1* 4 to 20 mAfor passive sensing of current, Rin = 14 Ohms

B0* 0 to 20mA

B1* 0 to 1 Ainput resistance Rin = 0.04 Ohms

B2* 0 to 5 A

AC

C0 0 to 20 mA ±1 % FSgalvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 0.04 Ohm to 14 OhmsC1 0 to 1 A

±1 % FSC2 0 to 5 A

vol

tag

e

DC

D0* 0 to 100 mV

±0.1 % FSinput resistance Rin by a 900 kOhms to 10 Mohms

D1* 0 to 1 V

D2* 0 to 10 V

D4* 0 to 75 V

D5* -10 V to +10 V ±0.1 % FS (± 20 mV)

AC

E0 0 to 100 mV

±1 % FS only galvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 700 kOhms to 10 Mohms

E1 0 to 1 V

E2 0 to 10 V

E4 0 to 50 V

resistance F* must be specified ±0.1 % FS two-wire connection

tem

per

atu

re p

rob

es P

t an

d N

i

Ni1000 J* -50 °C to +250 °C±0.2 °C (-50 °C to 100 °C) Ni1000/6180 ppm, two-wire connection

±0.2% MV (100 °C to 250 °C) measuring current of approximately 0.25 mA continuously

Pt100 K* -140 °C to +600 °C±0.2 °C (-140 °C to +100 °C) Pt100/3850 ppm, two-wire connection

±0.2 % MV (+100 °C to +600 °C) measuring current of approximately 2 mA continuously

Pt1000 K1* -140 °C to +600 °C±0.2 °C (-140 °C to +100 °C) Pt1000/3850 ppm, two-wire connection

±0.2 % MV (+100 to +600 °C) measuring current of approximately 0.2 mA continuously

Pt1000 K3 -10 °C to +50 °C ±0.06 °CPt1000/3850 ppm, two-wire connection

measuring current of approximately 0.2 mA continuously

ther

moc

oup

le

K (NiCr-Ni) N* -70 °C to +1300 °C

±0.3 % MV + 1.5 °C linearized, cold junction compensation, datalogger must be placed in recommendend working position

T (Cu-CuNi) T* -200 °C to +400 °C

J (Fe-Co) O* -200 °C to 750 °C

S (Pt10 %Rh-Pt) P* 0 °C to 1700 °C ±0.3 % MV +1.5 °C (200 °C to 1700 °C)

B (Pt30 %Rh-Pt) Q* 100 °C to 1800 °C ±0.3 % MV+1.0 °C (300 °C to 1800 °C) linearized, without cold junction compensation

bin

ary

sig

nal

potential-less contact S* binary signal

maximum resistance of closed contact is 1000 Ohms

minimum duration for recording is 200 ms

voltage, galvanically isolated S1 binary signal

voltage for „H“ state is 3 V to 30 Vdc @ 9 mA max

minimum duration for recording: 200 ms

galvanically isolated

pu

lse

cou

nte

r potential-less contact, galvanically isolated

CTU 31 bits, 5kHz max.

voltage change of the counter state is 3 V to 24 Vdc

backup power, filter bouncing

galvanically isolated

potential-less con-tact, open connector CTK 31 bits, 5kHz max.

maximum resistance of closed contact is 10 kOhms

minimum open contact resistance is 250 kOhms

backup power, filter bouncing

freq

uen

cy

input voltage signal measurement, gal-vanically isolated

FU 0 to 5 kHz

±(0.2 % MV + 1 Hz)

input voltage for „H“: 3 V to 24 Vdc @ 7 mA

minimum duration of input pulse: 30 us

resolution 1Hz galvanically isolated

measurement frequency switching contact, galvanically not isolated

FK 0 to 5 kHz

±(0.2 % MV + 1 Hz)

maximum resistance of closed contact is 10 kOhms

minimum open contact resistance is 250 kOhms

resolution 1 Hz minimum duration of input pulse: 30 us

RS

48

5

input for serial signal RS485 RP digital transmission

input supports Modbus RTU or Advantech

connected devices must have the same communication para-meters

input can work with up to 16 devices

galvanic isolated, MS can be equiped wit multiple RP modules

Parameters of inputs MS55D

Page 36: COMET measuring instruments katalog

Features:» clear presentation of measured data in tables and charts» easy export to MsExcel® files or PDF» software allows to control all MS functions, settings of alarms, browsing and printing of recorded data in tables or charts

ExportEasy export of measured data to XLS or DBF files. Export of measured data can be fully automatized. Software allows communication with MS monitoring systems via RS232, RS485, USB, via GSM modem or via Ethernet.

StatisticMaximal or minimal value, average, deviation, number of stored values, all these can be easily and clearly shown in table mode.

Table of measured values

chart of readings

statistic data

Clear presentation of measured data For a clear reading and processing the collected data is available user-friendly software which consists two parts - communication and analysis that allows you to work with spreadsheets and graphs.

Software interface is intuitive and easy to use thanks to software wizard. It ensures easy operation even for beginner who starts working with monitoring system MS. Software is Compatible with Windows®.

Analytical software SWR006

Page 37: COMET measuring instruments katalog

Data

Recording system MS is able to automatically send the measured data to a computer via the selected communication interface - USB, RS485, Ethernet or GSM modem connected to RS232.

Frequency of automatic reading can be set. This feature is available even if more MS systems is connected together.

Real time monitoring with software

Monitoring system MS allows to monitor all monitored sites in real time. Charts, tables, alarms can be displayed in „DISPLAY“ mode. This mode can be shared on multiple computers.

Data processing via web interfaceCurrent data can be displayed in web browser using HTML pages. Process of measuring can be simultaneously monitored by several user groups (techniques, management, etc.). Device must be connected to the Internet/Intranet.

Autodownload

settingsof communication

settingsof autodownload

display mode

web display mode

data displayed byweb browser

11

Page 38: COMET measuring instruments katalog

Comet database

For users of monitoring system MS is available software solution for data collection to one central database. It is based on MS SQL or MySQL. Software system is suitable for users who want to analyze data from multiple loggers MS or other products of Comet System.

Comet Database offers:• data stored in one place and accessible with Comet Database Viewer • to present data in table and graph• to print and export data• alarms via SMS texts and emails• acoustic and visual signalization of alarms• compatibility with all Comet System devices and 3rd party devices

Required software for running Comet Database?

Optional software SWR006 + Comet Database

Comet Database

Comet Database contains many useful tools for data analysis - graphs, tables, statistics etc. Comet database also offers advanced features - secured access to data, accounts administration, remote monitoring, error diagnostic, database backup etc.

Comet Database - system for data acquisition and analysis

Page 39: COMET measuring instruments katalog

Comet Database - system for data acquisition and analysis

When do you need Comet Database?

» for 24 hours supervision » as the storage place for your data» for simple and clear access to your measured values» as the storage place for all devices Comet System» for alarm SMS texts and e-mails

Analytical software SWR006 see page 10-11

13

Comet Database ViewerEach purchased Comet Database already contains one licence of Database Viewer. This low cost browser enables to several clients to view database from different places on network/internet. Another viewer licences can be purchased separately for other users of Comet Database. It is possible to assign limited rights for either read or write, or even administration rights for configu-ration.

Page 40: COMET measuring instruments katalog

Sensors / transmitters / probes

Comet System produces wide range of sensors which are compatible with monitoring system MS. There exist two ways of con-nection and their combination. Analog Sensors with 4-20mA, 0-10V output are wired to datalogger in star-like connection and digital sensors with RS485 output are linked in serial.

Analog sensors 4-20 mA, 0-10 VDigital sensors and regulators with RS485 output

Interior transmitter of temperature and CO

2

Output 4-20 mA 0-10 V

Type T8148 T8248

Temperature and humidty transmitter

Output 4-20 mA 0-10 V

Type T3110 T0210

Temperature and humidty transmitter with external probe

Output 4-20 mA 0-10 V

Type T3111 T0211

IInterior transmitter of temperature, humidity and CO

2

Output RS485

Type T7418

Temperature transmitter for Pt1000 probes

Output RS485

Type T4411

Temperature and humidity regulator with 0/I state inputs

Output RS485 2 x relay

Type H3430

Temperature, humidity and CO2 regulator

Output RS485 2 x relay

Type H6420

Other types of industrial and interior-sensors, including regulators and pro-bes can be found on our website www.cometsystem.cz

RS485IN - Galvanically isolated input for serial RS485 signal (for MS6D).

Input is designed for reading from devices supporting protocol ModBus RTU or Advan-tech. RS485IN port can be equipped addi-tionaly.

MP030 - RS232 connector with terminals

RS232 connector with terminals for RS232 interface connection by means of terminals, not by D-Sub connector.

MP021 - Converter RS232/RS485

Converter RS485/RS232 for serial port COMx at the PC side, including ac/dc adap-ter and terminator T485. Using this conver-ter is suitable in the case when the monito-ring system MS is away from the computer more than 10 meters.

MP022 - Converter USB/RS485

Converter for USB port at the PC side, including terminator T485. Powered from computer USB interface. Using this conver-ter is suitable in the case when the monito-ring system MS is away from the computer more than 10 meters.

M1061 - RP input module for datalogger MS55D for serial signal RS485

It is necessary to connect to one RP mo-dule only devices communicating with the same communication speed and the same communication protocol! Data logger can contain several RP modules. Protocols ModBus RTU or Advantech are supported.

MP042 - Ethernet communication port

Ethernet interface expands communication possibilities of measuring system MS. Com-munication via: SNMP, SOAP, www pages, Modbus TCP. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses.

MP023 – Converter RS485 to Ethernet

Designed for several data loggers connec-ted via RS485 network for connection to the computer via Ethernet. Including ac/dc adapter and terminator T485.

Note: For connection possibilities see page 6 and 7.

Communication, convertors

Optional accessories for monitoring system MS

Page 41: COMET measuring instruments katalog

Router is intended for MS6D, MS6R, MS6-Rack and MS55D which are equipped with an Ethernet interface MP042. Using GPRS / EDGE router can be recommended as a reliable, fast and low operating cost solution compared to using a dial-up connection with a modem GSM-KIT-M.

IP address of router is assigned by your mobile provider and it is related to your SIM card. Address may be private, public dynamic or public static. IP addres is public if router is accessed by it directly from internet. Static IP is fixed allocated to SIM by provider. Dynamic IP address is acquired from provider during connection of router to the GPRS/EDGE network. Dynamic IP is variabled. No everyone provider supports public IP! Open VPN tunnel with a private IP address can be used. This router allows using of SMS messages for one MS monitoring system.

Software Comet Database offers more tools for data management and alerts.

KIT-GSM-M

For data transmission from the data logger MS to Computer must be used two modems. One on the side of logger and second on side of PC. In comparison with the GPRS / EDGE router data transfer is slower. This modem is suitable for users who need to acquire alarm SMS texts from one monitoring system MS. Up to four phone numbers can be set up.

KIT-GSM-W

The hardware of this kit is identical to KIT-GSM-M. However it is preconfigured for use with the software Comet Database. When you connect modem with PC where Comet Database is installed you get a tool for 24-hour surveillance of critical events via SMS texts (see picture above). Unlimited phone numbers can be set up.

Wi-Fi adapter - TP-LINK-TLWifi adapter for wireless connection of data logger to Ethernet network.

MP018Relay module contains 16 mains relays 250V/8A with switching-over contacts. Each relay can be controlled based on alarm cre-ation at different input channels accordingly to setting of user program. It is necessary to buy connection cable MP017. We also offer brackets on DIN rail MP019 and MP20.

MP050Relays module is designed for mounting into MS6-Rack. It contains 16 mains relays maximum voltage 50 V AC/75 Vdc with switching-over contacts. A connection cable and blind plug are supplied.

MP016 Terminal with dual line alphanumerical LCD and control buttons, audio alarm indication and 32 alarm LEDs - for panel mounting or mounting to a case lid. Identical functions as built-in terminal of MS data logger. Maximum cable length to data logger 50m. It is necessary to order the MP017 con-nection cable to data logger (length of cable 60cm, 5m, 10m).

MP032 Built in a IP54 protection case, including 2m cable with covered ter-minals.

MP048 MS6D datalogger in IP54 protection case with connected terminal at the lid.

MP049 MS55D datalogger in IP54 protection case with connected terminal at the lid.

MP033Case with IP65 protection with wall holders and MS data logger holders - no cutout in the lid.

Note: Dimensions of all cases is 270 x 570 x 140 mm. The relay board MP018 can be placed inside.

A1940Universal ac/dc adapter 24 Vdc/1 A for con-nection to terminals, switch-mode.

A1759Universal linear ac/dc adapter 230 V-50 Hz/21 Vdc/1 A - for connection to terminals.

A5948Power supply 230V-50Hz/24Vdc/2,5A for DIN rail 35mm, dual terminals 24Vdc, switch-mo-de, including DIN rail of 100mm length.A6963Backup power supply A6963 with batte-ry A7963 - model MINI-BAT/24DC/1.3AH. Power supply is designed for mounting to 35 mm DIN.

A6966It is necessary to buy two pieces of batteries A7966 12 V/7 Ah for this backup power supply. Not suitable for installation into closed switchboard.

Other accessories for installation and mounting can be found on our website.

KIT-GSM-W

24h supervision via email or SMS texts

GPRS/EDGEAPN

Internet

SMS cable

DynDNS server for public dynamic IP

GPRS/EDGE router with SIM card with public static or dynamic IP address

SWITCH

Switching and controlling

Power and backup adapters

A solution for extreme conditions

– up to IP65

External terminal

GPRS/EDGE router - MP052

15www.cometsystem.cz

GSM/Wi-Fi communication

Page 42: COMET measuring instruments katalog

•progra

mmablesensors

oftemperature,

humidity,atmos

phericpressure

andCO2

•industryandin

teriordesign•h

ighquality,accu

rateandstables

ensors

•valuescomput

edfromambien

ttemperaturea

ndrelativehum

idity

•traceablecalib

rationcertificate

withtraceability

withENISO/IEC

17025

CaseofsensorismadeofABSwhichisveryresistanttomechanicaldamage.

AlltransmittersettingscanbedonebyPC.

Sealinglidprotectselectronicsfromdustandsplashingwater.

RTDPt1000temperaturesensortogetherwithstate-of-the-artcapacitivepolymersensorensuresexcellentcalibration,longtermstability,inertiaagainstwaterandcondensation.

Sensorcoverwithfilterfromstainlesssteelmesh.Filteringabilityis0,025mm.

Theterminalsfortheoutputsignalandpower.

with 4 - 20 mA or 0 - 10 V outputs

Theintrinsicallysafetransmittersareintendedforuseinpotentiallyexplosiveenvironments(zone2).

availablefromJune2014

Externalmountingholesforeasyandfastmountingwithouttheneedtotakeofflidcover.

Page 43: COMET measuring instruments katalog

SENSOR MODEL T3110Ex T3113Ex T3111Ex

temperaturerange -30 to +80°C -30 to +125°C -30 to +105°C

accuracy ±0,4°C

humidityrange 0 to 100 %RV

accuracy ±2,5 %RV

output 4-20 mA

recommended calibration interval 1 year

protection class of the case with electronics IP65

protection class of the sensors cover IP40

temperature operating range of the case with electronics -30 to +60°C

temperature operating range of the sensing element -30 to +80°C -30 to +125°C -30 to +105°C

humidity operating range 0 to 100 %RV

electromagnetic compatibility EN 61326-1

Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

Don ,t be explosive

ATEX certification for use in potentially explosive environments.

The intrinsically safe transmitters version T311xEx are intended for use in potentially explosive atmos-phere (zone 2).

Programmable sensors of tempera-ture and humidity with accurate and stable sensors - 4-20mA output.

In the case of need to have Ethernet output, use P2520 transmitter.

II 3G Ex ic llC T6 Gc

Page 44: COMET measuring instruments katalog

Building management needs quality and reliable components. Our instruments which measure temperature, humidity, atmosphericpressureandCO2areanintegralpartoftheseindustry-leadingsolutions. Process industries is distinguished by its capital demands. A competition across the market is still growing and creates additionalpressureontheprices.Ourcompanyhasagoodunderstandingofthissituationandthusprovidesveryreliableandpreciseproductsforaverycompetitiveprice. Meteorology is thescienceoftheatmosphere,whoseknowledge isessential inmanyfieldsofhumanactivity.Forexample,transportation,agricultureandthemilitaryneedsensitive,accuratedeviceswithalargedynamicrange,whichareverystableovertime.COMETsensorsmeettheserequirements.Oursensorsalongwitharadiationshieldmayformthebasisforalong-termweatherstationformonitoringclimateandairquality.

In the food industry, environments, supermarkets and wherever thereisaneedtomonitorcriticalvariablesinrelationtoHACCPregulations,COMETsensorsandtransducersmaybeused.AlongwithotherCOMETproductssuchmonitoringsystemsMS6andMS55D,itispossibletocreateacomprehensivesystemforcollecting,recording,analyzingandalerting.

Healthcare and laboratories arecharacterizedbysterileenvironments.COMETsensorscanservewelleveninthesedemandingandwiderangeofapplicationsfocusingonmonitoringtemperature,CO2andothercriticalparametersinthecontextofGLPandGMPregulations.

Potentially explosive environments arenotsuitableforcommonsensors.SelectedtypesofdevicesseriesT311xcomplywiththerequirementsoftheATEXdirectiveforuseinpotentiallyexplosiveenvironments(zone2).

Applications

Temperature Temperature is measured by RTD sensor Pt1000/3850 ppm which can be integratedintothehousingof transducer, intotheduckstemorcanbeusedonthecableaswell. Themeasuredtemperaturecanbedisplayedin°Cor°F,accordingtothesettingsofthesensor.

State-of-the-art capacitivepolymer sensorensuresexcellent long termcalibration stabilityandinertiaagainstwaterandcondensation.Transmittersareavailableinwall-mount,duct-mountandbartypes.AlsowithaT+RHprobeonacableareavailable.Theyarealsoavailableinmodificationformeasuringintothepressureupto25bars(modelsT3111P,T0211P).

Relative humidity

Measuredvaluesarealsoconvertedtootherhumidityinterpretation-dewpointtempera-ture,absolutehumidity,specifichumidity,mixingratioorspecificenthalpy.

Computed values

Transmitter formeasuringofbarometricpressure isequippedwithanabsolutepressuresensorofhighaccuracywhichensuresexcellent long termstability.Thedisplay readingandpressureoutputisuserselectableintheseunits:hPa,kPa,mbar,mmHg,inHg,inHO,PSI,oz/in2.

Barometric pressure

TheCO2measurementisbasedona2-source,2-beamprocess.CO2measurementwithlong--termstabilityisguaranteedthankstotheprovennon-dispersiveinfrared(NDIR)CO2mea-surementcell.Theuniquepatentedauto-calibrationprocedurecompensatesforagingoftheinfraredsourceandguaranteeshighreliability,longtermstabilityandeliminatestheneedofperiodicalrecalibrationinthefield.

Carbon dioxide level - CO2

Measured values

Page 45: COMET measuring instruments katalog

Měřící a záznamový systém MS v různých provedeních

3

Sensors and transducer P & T series

ThecompanyCOMETSystem,s.r.o.producesinexpensi-vesensorsandtemperaturetransmittersP series with fixed and unchangeable temparature range.

Programmable sensors T series offer more flexi-bility. Devicecontainsamicroprocessorbasedcontrolcircuitry.Thisconceptallowstheusertochoosemeasu-ringrangeforeachoutput.Moreover,thereisanoptiontosetupcomputedvaluessuchasdewpoint,absolu-tehumidity,specifichumidity,mixingratioandspecificenthalpy.Programmabletransmitteralsoallowsadjust-mentofthesensorbytheuser.

ProbeP0120isdesignedformeasurementofairtemperature,transducerP0132fortemperaturemeasurementinstainlesssteelwell(wellisnotincluded).TransducersP41x1withoutowntemperaturesensoraredesignedforsignalconversionfromRTDsensorPt1000(3850ppm/°C)tothecurrentflow.P6181transducerisdesignedforsignalfromsensorPt100.Temperatureran-geafallmodelsisunchangeableandtheoutputisananalogsignal4-20mA.Alltransducerscanbepowerdfromcurrentloop.ProtectionofelectronicpartisIP65.

temperature sensors and transducers for RTD sensors Pt100, Pt1000Output4–20mAP

Basic division of sensors and transducers P and T series:P -inexpensivesensorsandtemperaturetransmitterswithafixedmeasuringrangeT-Programmabletransmitterswithdisplay » Industrialandinteriordesign » Possibilityofvoltageorcurrentoutput » Variablemeasuringrange » Computedvalues » Long-termstabilityofsensors » Useradjustmentofsensors

*ForPt100probe-two-wire,three-wireandtwo-wirewithcompensationloopconnection**MV-measuredvalue

Sensor models and their specification

measured rangetransducer for exteral probe Pt1000 (*Pt100) built-in temperature sensor

type accuracy type accuracy

-100°Cto+200°C P6181* ±0,3°C,±0,4°Cnad100°C

-100°Cto+30°C P4141 ±0,3°C

-50°Cto+50°C P4191 ±0,3°C

-30°Cto+80°C P4121 ±0,3°C P0120 ±0,4°C

0°Cto+35°C P4151 ±0,2°C

0°Cto+150°C P4131 ±0,3°C P0132 ±0,4°C,above100°C0,4%°CinMV**

0°Cto+250°C P4161 ±0,4°C

0°Cto+400°C P4171 ±0,7°C

Page 46: COMET measuring instruments katalog

TProgrammable sensors and transducers withoutput4–20mA,0-10V

Programmable sensors T series canbesetupbymeansofthePCconnectedviatheoptionalSP003communicationcable.

Software TSensors allows you to: »Setthedesiredrangeoftheanalogoutput»Assignmeasuredvaluetooutput»Selectandassignthecomputedvalue»Makeauseradjustmentofthesensor»Turnthedisplayoff

Transmitter version with watertight male connector TxxxxLWaterproof connector for easy connecti-on anddisconnection of the output cable(connectorLumbergRSFM4IP67).PleasespecifyyourorderwithletterLbehindmo-delcode(e.g.TxxxxL).TransmitterversionTxxxxDAnoptionwithitsdisplayplacedperpendi-cularlytotheaxisofmeasuringstem.

computed valuesAbsolute humidity Accuracy:±1,5g/m3atambienttemperatureT<25°Cformoredetailsseemanual.Range:0to400g/m3

Dew point temperature Accuracy:±1,5°Catambienttempera-tureT<25°CandrelativehumidityRH>30%,formoredetailsseemanual.Range:-60to+80°C(-76to176°F)

Specific humidityAccuracy:±2g/kgatambienttemperatureT<35°CRange:0to550g/kg

Specific enthalpy Accuracy:±3kJ/kgatambienttemperatureT<25°CRange:0to995kJ/kg

Mixing ratio Accuracy:±2g/kgatambienttemperatureT<35°CRange:0to995g/kg

Industrial design

T3113 – temperatureandhumiditytransmitter****

Transmitter version T311xEX for poten-tially explosive environments (zone 2). Selected types of devices series T311xcomplywiththerequirementsoftheATEXdirectiveEN60079-11.

measured values temperature relative humidity temperature + relative humidity atm. pressure C02

SENSOR MODEL 4 - 20 mA T4111 T0110 T1110 T3110 T3113(D), T3117(D) T3111 T3111P T2114 T5141 T5140

0 - 10 V T4211 - - T0210 T0213(D) T0211 T0211P T2214 T5241 T5240

temperaturerange -200to+600°C -30to+80°C - -30to+80°C -30to+125°C -30to+105°C -30to+105°C - - -

accuracy ±0,4°C - ±0,4°C ±0,4°C ±0,4°C ±0,4°C - - -

relativehumidityrange* - - 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH - - -

accuracy - - ±2,5%RH ±2,5%RH ±2,5%RH ±2,5%RH ±2,5%RH - - -

barometricpressure

range - - - - - - - 600to1100hPa - -

accuracy - - - - - - - ±1,3hPa - -

C02

range - - - - - - - - 0to10000ppm 0to2000ppm**

accuracy - - - - - - - - ±(110ppm+2% ofmeasuredvalue)

±(50ppm+2%ofmeasuredvalue)

computedvalues NO NO NO YES YES YES YES NO NO NO

recommendedcalibrationinterval twoyears twoyears oneyear oneyear oneyear oneyear oneyear oneyear fiveyears fiveyears

protectionclassofthecasewithelectronics IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP54 IP65 IP30

protectionclassofthesensorscover - IP65 IP40 IP40 IP40 IP40 IP40 - IP65 -

temperatureoperatingrangeofthecasewithelectronics -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+60°C

temperatureoperatingrangeofthesensingelement - -30to+80°C -30to+80°C -30to+80°C -30to+125°C -30to+105°C -30to+105°C - -40to+60°C -

humidityoperatingrange 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 5to95%RH

barometricpressureoperatingrange - - - - - -

probeforcom-pressedairupto

25bars600to1100hPa 850to1100hPa 850to1100hPa

mountingposition anyposition scableglandupwards

cableglandupwards

cableglandupwards

cableglandupwards***** anyposition*** anyposition*** průchodkou

nahoru libovolná cableglandupwards

storagetemperaturerange -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -40to+60°C -40to+60°C

electromagneticcompatibility ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1ČSNEN55011

ČSNEN61326-1ČSNEN55011

weight 140g 140g 150g 150g 230g/580g 210(250,330)g 260(300,380)g 130g 150g 250(280,340)g

accuracyofcurrentoutput(devicewitho-utprobe)TMR...temperaturemeasuringrange

±(0,15+0,1%TMR)°C

Page 47: COMET measuring instruments katalog

Choose the appropriate sensor model

5

* Therelativehumiditymeasuringrangeislimitedattemperaturesabove85°C,seemanualsfordevices.

*** Ifitcanleadtolongtermcondensationofwater,itisnecessarytousetheprobeatpositionwithsensorcoverdownwards.

***** Mountingposition„cableglandupwards“isrecommendedforfreespace,intheair-conditioningductyoucanplacethedeviceinanyposition.

**** Stemslengthlongerthan75mmaremadeofstainlesssteel.

** Customrange10000ppm.

measured values temperature relative humidity temperature + relative humidity atm. pressure C02

SENSOR MODEL 4 - 20 mA T4111 T0110 T1110 T3110 T3113(D), T3117(D) T3111 T3111P T2114 T5141 T5140

0 - 10 V T4211 - - T0210 T0213(D) T0211 T0211P T2214 T5241 T5240

temperaturerange -200to+600°C -30to+80°C - -30to+80°C -30to+125°C -30to+105°C -30to+105°C - - -

accuracy ±0,4°C - ±0,4°C ±0,4°C ±0,4°C ±0,4°C - - -

relativehumidityrange* - - 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH - - -

accuracy - - ±2,5%RH ±2,5%RH ±2,5%RH ±2,5%RH ±2,5%RH - - -

barometricpressure

range - - - - - - - 600to1100hPa - -

accuracy - - - - - - - ±1,3hPa - -

C02

range - - - - - - - - 0to10000ppm 0to2000ppm**

accuracy - - - - - - - - ±(110ppm+2% ofmeasuredvalue)

±(50ppm+2%ofmeasuredvalue)

computedvalues NO NO NO YES YES YES YES NO NO NO

recommendedcalibrationinterval twoyears twoyears oneyear oneyear oneyear oneyear oneyear oneyear fiveyears fiveyears

protectionclassofthecasewithelectronics IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP54 IP65 IP30

protectionclassofthesensorscover - IP65 IP40 IP40 IP40 IP40 IP40 - IP65 -

temperatureoperatingrangeofthecasewithelectronics -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+60°C

temperatureoperatingrangeofthesensingelement - -30to+80°C -30to+80°C -30to+80°C -30to+125°C -30to+105°C -30to+105°C - -40to+60°C -

humidityoperatingrange 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 0to100%RH 5to95%RH

barometricpressureoperatingrange - - - - - -

probeforcom-pressedairupto

25bars600to1100hPa 850to1100hPa 850to1100hPa

mountingposition anyposition scableglandupwards

cableglandupwards

cableglandupwards

cableglandupwards***** anyposition*** anyposition*** průchodkou

nahoru libovolná cableglandupwards

storagetemperaturerange -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -30to+80°C -40to+60°C -40to+60°C

electromagneticcompatibility ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1ČSNEN55011

ČSNEN61326-1ČSNEN55011

weight 140g 140g 150g 150g 230g/580g 210(250,330)g 260(300,380)g 130g 150g 250(280,340)g

Page 48: COMET measuring instruments katalog

Interior design

measured values temperature temperature + relative humidity temperature + CO

2 atm. pressure

SENSOR MODELoutput 4 - 20 mA T0118 T3118 T8148 T2118

output 0 - 10 V T0218 T3218 T8248 T2218

temperaturerange 0to+50°C 0to+50°C 0to+50°C -

accuracy ±0,5°C ±0,5°C ±0,5°C -

relativehumidity

range - 5to95%RH - -

accuracyinrange5-60%at23°C ±2,5%RH - -

accuracyinrange60-95%at23°C - ±3%RH - -

atmosphericpressure

range - - - 600to1100hPa

accuracy - - - ±1,3hPa

C02

range - - 0to2000ppm -

accuracy - - ±(50ppm+2%ofmeasuredvalue“) -

computedvalues NO YES NO NO

recommendedcalibrationinterval twoyears oneyeartwoyears(tempe-rature)/fiveyears

(CO2)oneyear

protectionclassofthecasewithelectronics IP20

temperatureoperatingrange 0to+50°C

humidityoperatingrange 0to100%RH

atm.pressureoperatingrange - - 850to1100hPa 600to1100hPa

storagetemperaturerange -30to+80°C

electromagneticcompatibility ČSNEN61326-1 ČSNEN61326-1 ČSNEN61326-1ČSNEN55011 ČSNEN61326-1

weight 150g

TProgrammable sensors withoutput4–20mA,0-10V

InteriorsensorshavealltheadvantagesofTseriessensorsinindu-strialdesign.Thisisthesameconceptwithadigitalmicroprocessor.Itdiffersbythetypeofhousingwhichhasbeendesignedwithregardtofunctionalandattractivedesign.Theyaremadeforeasyinstallationinastandardwayintoaflush-mountedwiringbox.

Easyinstallationinastandardwayintoaflush-mountedwiringbox.Minimaldepthoftheboxis40mm.

0to1000ppm

1000to1200ppm

1200to2000/10000ppm

LimitsofLEDindicationmaybechangedbyuser.

T8148-programmablesensoroftemperatureandC02

Sensor models and their specification

Common parameters for sensors T series» Forsensorswithcurrentoutputeachloopisgalvanicallyisolated.» Sensorswithcurrentoutputarepoweredbythecurrentloop(9-30V),sensorswithvoltageoutputarepoweredbyvoltage15-30V.» Incaseoferroroutputfordeviceswith4-20mAis<3.8mAor>24mA.» Incaseoferroroutputfordeviceswith0-10Voutputis<-0.1Vor>10.5V.

Page 49: COMET measuring instruments katalog

Optional accessories

7

The settings of programmable sensors and transducersAlltransmittersettingsareperformedbymeansofthePCconnectedviatheoptionalSP003communicationcable.ProgramTsensorfortransmittersettingisavailabletodownloadfreehttp://www.cometsystem.cz/products/reg-SensorsThesoftwareenablestoassigneachcurrentloopoutputmeasurevalue(temperature,relativehumidity,computedvalue)anditsrange.

T-sensoralsoenablesadjustmentofthesensor.Adjustmentmeansactionresultinginsettinginstrumenttostate,whenitsactu-almeasurementaccuracyisidenticalorbetterthanmeasurementaccuracyspecifiedininstructionmanual.Forthisoperationisneededthesameequipmentasforcalibration-aspecialequipmentforconstanttemperature,relativehumidityorpressuregeneration(acalibrationbox).ForcalibrationandadjustmentofrelativehumiditycanbeusedhumiditystandardsHM023andHM024.

SP003-cablefortransmitteradjustmentviaUSBport.

MD046-Vesselforadjustmentandcalibrationofhumidity.

HM023-Setofhumiditystandards10%RHwith5applicationpads.

HM024-Setofhumiditystandards80%RHwith5applicationpads.

TSensor-freewaresoftwareforsensorconfiguration

Mounting accessoriesK1427-FemaleconnectorELKAforTxxxxLtransmitterswithmaleconnectorLumbergforeasyconnection/discon-nectionoftheoutput.IP67protection.

PP90–Right-angledstainlesssteelflange.

PP4–plasticflatcircularflange

SP004-Plasticglandfordirectmountingofthehumidityprobetoa29mmdiameterhole.

The probe formeasuring themoisture of compressed air should beplaceddirectlyon thepressurepipelines toachievehighermeasure-ment accuracy and fast response times. But there are cases wheresuchplacementisnotpossible.Thereasonisthehighairspeed,hightemperature,highpollution,smalldiameterpipes,etc.Suchsituationcanbesolvedbyplacingtheprobeintotheflowmeasuringchamber.Thepictureshowsthebasiclayoutofthesamplingsystemwithcham-berSH-PP.

SH-PP-Flowchamberforcompres-sedairmeasurementup to25bars-stainlesssteelDIN1.4301inletandoutletconnection-G1/8threadhu-midityprobeconnection-G1/2thre-adscrew-couplingnotincluded.

Protection of sensors

F8000-Solarradia-tionshieldfortrans-mitterswithT+RHprobeonacable

F5200-Greysensorcoverwithfilterfromstainlesssteelmesh,filteringability0,025mm.F5200B-Blacksensorcoverwithfilterfromstainlesssteelmesh,filteringability0,025mm.

F5300-Teflon(PTFE)sensorcover(whitecolour),withincreasedresistanceagainstsplashingwater,non-absorbentsurface,doesnotrust.Poroussize25μm.Temperaturerange-40°Cto+125°C.

1...sampling2...closingvalve3...probe

4...flowchamberSH-PP5...closingvalve6...outlettube

F0000-Sinteredbronzesensorcover.Filteringability0.025mm.

Page 50: COMET measuring instruments katalog

• programmable sensors of temperature, humidity, atmospheric pressure and CO2 with

two-state inputs and relay outputs • industry and interior design • high quality, accurate

and stable sensors • values computed from ambient temperature and relative humidity •

traceable calibration certificate with traceability with EN ISO/IEC 17025

with serial RS485/RS232 output

RS485

Page 51: COMET measuring instruments katalog
Page 52: COMET measuring instruments katalog

Applications

Building management needs quality and reliable components. Our instruments which measure temperature, humidity, atmo-spheric pressure and CO2 are an integral part of these industry-leading solutions. Industry is distinguished by its capital demands. The competition across the market is still growing and creates additional pre-ssure on the prices. Our company has a good understanding of this situation and thus provides very reliable and precise products for a very competitive price. Meteorology is the science of the atmosphere, whose knowledge is essential in many fields of human activity. For example, transportation, agriculture and the military need sensitive, accurate devices with a large dynamic range, which are very stable over time. COMET sensors meet these requirements. Our sensors along with a radiation shield may form the basis for a long-term weather station for monitoring climate and air quality.

In the food industry, environments, supermarkets and wherever there is a need to monitor critical variables in relation to HACCP regulations, COMET sensors and transducers may be used. Along with other COMET products such monitoring systems MS6 and MS55D, it is possible to create a comprehensive system for collecting, recording, analyzing and alerting.

Healthcare and laboratories are characterized by sterile environments. COMET sensors can serve well even in these demanding and wide range of applications focusing on monitoring temperature, CO2 and other critical parameters in the context of GLP and GMP regulations.

TemperatureTemperature is measured by RTD sensor Pt1000/3850 ppm. Probes P1000 of different lengths and types can be connected to transducers. The measured temperature can be displayed in °C or °F, according to the settings of the sensor.

State-of-the-art capacitive polymer sensor ensures excellent long term calibration stabilityand inertia against water and condensation. Transmitters are available in wall-mount, ductmount. They are also available in modification for measuring into the pressure up to 25 bars.

Relative humidity

Measured values are also converted to other humidity interpretation - dew point tempera-ture, absolute humidity, specific humidity, mixing ratio or specific enthalpy.

Computed values

Transmitter for measuring of barometric pressure is equipped with an absolute pressure sensor of high accuracy which ensures excellent long term stability. The display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

Barometric pressure

Carbon dioxide level - CO2

A multiple point CO2 and temperature adjustment procedure leads to excellent CO2 mea-surement accuracy over the entire temperature working range; this is a must for process control and outdoor applications. The dual wavelength NDIR CO2 sensing procedure com-pensates automatically for ageing effects. The CO2 module is highly resistant to pollution and offers maintenance free operation and outstanding long term stability.

Measured values

Binary inputsSelected devices feature up to three binary inputs for connecting smoke detectors, floodings, breaking glass, door contacts, etc. A voltage-free contact, open collector or two-state voltage signal can be connected.

Page 53: COMET measuring instruments katalog

Měřící a záznamový systém MS v různých provedeních

3

Pharmaceuticals and laboratories Technological processes and production

Building managementFood industry

Monitoring of areas and places for storage of drugs at temperatures down to - 200 °C.

Monitoring of storage conditions and production proce-sses in the temperature range from - 200 °C to + 600 °C.

Monitoring of critical variables in relation to HACCP regulations with the possibility of imme-diate alert to unforeseen events that could lead to the devaluation of goods.

Comet devices offer reliable components measuring temperature, humidity, atmospheric pressure and CO2.

smoke detector

flood detector

door contact

motion detectorRS485

SCADA / PLCsystems

Page 54: COMET measuring instruments katalog

Sensors and regulators of temperature, humidity, barometric pressure and CO2 concentration convert measured values to digital serial output the RS485 and RS232 link parameters. These devices support communication protocols Modbus RTU and protocol compatible with standard Advantech-ADAM. By means of this communictaion via serial line the measured values can be read and some settings changed. Parameters can be set from the regulator´s keypad or from a computer.

Computerized design ensures maximum long term stability, user adjustment and fail indication. This concept allows the user to choose measuring range for each output. Moreover, there is an option to set up computed values such as dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy. State-of-the-art capacitive polymer sensor ensures excellent long term calibration stability and inertia against water and condensation. Devices are designed for measurement of air without aggressive ingredients.

Basic division of devices:

Programmable industry regulators with relay output and serial output RS485/RS232

Programmable sensors with serial output without relay outputs

» Regulators with relay outputs» Regulators with power relay 230Vac/8A» Regulators with two-state inputs, with relay output and serial output RS485/RS232

» Industry design with serial output RS485/RS232» Interior design with serial output RS485/RS232

• Two relay outputs• Three two-state outputs• Keypad for settings• Acoustic and visual indication of alarms

Advantages:• Compact size• The stems of length up to 700 mm• Device version with connector Lumberg for easy connection• External probe of length up to 4 metres

page 5 - 11 page 12- 16

TH

Advantages:

Sensors and regulators with serial output RS485/RS232 and with relay outputs

Page 55: COMET measuring instruments katalog

5

Programmable industry regulators

Regulators are designed for two-state control of e.g. heating, ventilation, humidifier, dehumidifier, etc. They are equipped with two relay outputs for alarm indication or control of external devices. Each relay can be assigned to any measured or computed value and comparing limit, delay, hysteresis and audible alarm can be set up.

Regulators are made with the power relay output 250VAC/8A, or with relay output 50V/2A. Devices with low voltage relays can be equipped with a serial output RS485 or RS232. These regulators are equipped with three binary inputs for detection of two-state events - e.g. water, smoke, glass break detection, door contact.

• Mesured values - temperature, relative humidity, computed values and CO2 concentration

• Versions with the stem, the external probe on the cable and with external probe into the pressure environments of up to 2,5 MPa

• Mesured values - temperature, relative humidity, computed values

• Versions with the stem, the external probe on the cable and with external probe into the pressure environments of up to 2,5 MPa

• power relays 250Vac/8A

• Mesured values - temperature, relative humidity, computed values and CO2 con- centration

• Versions with the stem, the external probe on the cable and with external probe into the pressure environments of up to 2,5 MPa

• Two-state inputs

page 6 - 7

page 6 - 7

page 8 -11

Regulators with two-state inputs, with relay output and serial output RS485/RS232

Regulators with relay outputs

Regulators with power relay outputs

H

50V

50V

250V

Sensors and regulators with serial output RS485/RS232 and with relay outputs

Page 56: COMET measuring instruments katalog

Programmable industry regulators

Regulators with relay and power relay output

Electrical wiring of regulator with low

voltage relay output.

Electrical wiring of regulator with power

relay output.

power supply relay 1 relay 2

Connector for SP003cable connection toa computer USB port

relay 1 relay 2

Connector for SP003cable connection toa computer USB port

internal fuse T1,25A

power supply 110 - 240 Vac

holes for devicemounting

MEASURED VALUES temperature + relative humidityTemperature +

relative humidity + CO

2

C02

SENSOR MODEL WITH 2 x Relay H3020 H3023 H3021 H3021P H6020 H5021 H5024

2 x Relay 250Vac/8A H3060 - H3061 H3061P - - -

temperaturerange -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C - -

accuracy ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - -

relative humidityrange (without condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH - -

C02

range - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - ± (50ppm+2% of

measured value)

± (100ppm+5% of measured value)

±± (50ppm+2% of measured value)

two-state inputs NO NO NO NO NO NO NO

computed humidity values YES YES YES YES YES NO NO

supply voltage for device with 50 V relay 9-30 Vdc

supply voltage for regulators with power relay 250Vac / 8A 110 - 240 Vac, 50 - 60 Hz - 110 - 240 Vac,

50 - 60 Hz110 - 240 Vac, 50 - 60 Hz - - -

relay outputs - max. switching voltage 50 V / max. current 2A / max. power 60VA H3020 H3023 H3021 H3021P H6020 H5021 H5024

relay outputs 230Vac / 8A - max. switching voltage 250V / max. current 8A / max. power 2000 VA/AC, 192 W/DC H3060 - H3061 H3061P - - -

recommended calibration interval 1 year 1 year 1 year 1 year5 years CO2/ 1 year RH / 2 years temperature

5 years 5 years

protection class of the case with electronics IP 65 IP 65 IP 65 IP 65 IP 30 IP 65 IP 30

protection of the RH /CO2 sensors IP 40 / - IP 40 / - IP 40 / - IP 40 / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C - -

humidity operating range (without condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - up to 2,5 MPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position cable gland upwards

cable gland upwards any position any position cable gland

upwards any position cable gland upwards

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight device with 2 x relay / 2 x relay 250Vac/8A 350 g / 420 g 420 g 400 (440,520) g 450 (490, 570) g 350 g 420 (450,510) g 330 g

Absolute humidityAccuracy: ±1,5g/m3

at ambient temperature T < 25°C for more details see manual.Range: 0 to 400 g/m3

Dew point temperature Accuracy: ±1,5°C at ambient temperature T<25°C and relative humidity RH>30%, for more details see manual.Range: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2,1g/kg at ambienttemperature T < 35°CRange: 0 to 550 g/kg

Computed humidity values

HProgrammable regulators with relay outputs are designed to measure temperature, relative humidity and CO2 concentration in chemical non--aggressive environment. Used for alarms signalization and control of external devices.The devices are available in wall and duct mounting models or with a cable probe. Programmable regulators with outputs to power relays are powered by AC 110V to 240V. The advantage is the possibility of direct control of external power circuits.

Normally open contact of relay - when alarm condition is true, contact is closed Normally closed contact of relay - when alarm condition is true, contact is open

Two output relays can be set from the keypad or from a computer.

* Custom range 10 000 ppm for extra fee. Accuracy ± (100ppm+5% of measured value).

« H306x devices have three glands on the top and one of them is sealed, then one gland for power supply on the bottom

holes for devicemounting

Page 57: COMET measuring instruments katalog

Choose the appropriate sensor model

7

MEASURED VALUES temperature + relative humidityTemperature +

relative humidity + CO

2

C02

SENSOR MODEL WITH 2 x Relay H3020 H3023 H3021 H3021P H6020 H5021 H5024

2 x Relay 250Vac/8A H3060 - H3061 H3061P - - -

temperaturerange -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C - -

accuracy ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - -

relative humidityrange (without condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH - -

C02

range - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - ± (50ppm+2% of

measured value)

± (100ppm+5% of measured value)

±± (50ppm+2% of measured value)

two-state inputs NO NO NO NO NO NO NO

computed humidity values YES YES YES YES YES NO NO

supply voltage for device with 50 V relay 9-30 Vdc

supply voltage for regulators with power relay 250Vac / 8A 110 - 240 Vac, 50 - 60 Hz - 110 - 240 Vac,

50 - 60 Hz110 - 240 Vac, 50 - 60 Hz - - -

relay outputs - max. switching voltage 50 V / max. current 2A / max. power 60VA H3020 H3023 H3021 H3021P H6020 H5021 H5024

relay outputs 230Vac / 8A - max. switching voltage 250V / max. current 8A / max. power 2000 VA/AC, 192 W/DC H3060 - H3061 H3061P - - -

recommended calibration interval 1 year 1 year 1 year 1 year5 years CO2/ 1 year RH / 2 years temperature

5 years 5 years

protection class of the case with electronics IP 65 IP 65 IP 65 IP 65 IP 30 IP 65 IP 30

protection of the RH /CO2 sensors IP 40 / - IP 40 / - IP 40 / - IP 40 / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C - -

humidity operating range (without condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - up to 2,5 MPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position cable gland upwards

cable gland upwards any position any position cable gland

upwards any position cable gland upwards

storage temperature range -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight device with 2 x relay / 2 x relay 250Vac/8A 350 g / 420 g 420 g 400 (440,520) g 450 (490, 570) g 350 g 420 (450,510) g 330 g

15

0

Φ 18.5

Esc

Set

ALARM 2

ALARM 1

Esc

Set

ALARM 2

ALARM 1

Φ 18

75

Esc

Set

ALARM 2

ALARM 1

Φ 18

75

Esc

Set

ALARM 2

ALARM 1

Φ 18

15

5

Esc

Set

ALARM 2

ALARM 1

Esc

Set

ALARM 2

ALARM 1

(88

)1

(2,4

)m

Φ18

Esc

Set

ALARM 2

ALARM 1

Φ18

(15

0)

G1/2

HEX 19

O-ring

19

12

60

1(2

,4)

m

Specific enthalpyAccuracy: ± 3kJ/kg at ambienttemperature T < 25°CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2,2g/kg at ambienttemperature T < 35°CRange: 0 to 995 g/kg

Page 58: COMET measuring instruments katalog

HProgrammable industry regulators

Regulators with two-state inputs, with relay output and serial output RS485/RS232

The regulators are designed for online monitoring of tempera-ture in °C or °F, relative humidity of air without aggressive sub-stances, atmospheric pressure, CO2 and three binary inputs for detection of two values.

Measured temperature and relative humidity can be recalculated to other humidity interpretation like dew point, absolute humidi-ty, specific humidity, mixing ratio and specific enthalpy. You can set the altitude correction (offset) and choose the pressure unit: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

The regulators is in a durable plastic case with connection ter-minals and sensors of temperature and humidity in the cover with a stainless steel mesh filter. The CO2 sensor can be installed inside the device or in the cable probe.

Transmitter circuitry is galvanically isolated from power circuitry to prevent collision in RS485 network.

Serial output RS232 is not galvanically isolated.

The transmitter works with ModBus RTU communication protocol or with Advantech ADAM compatible protocol. Protocol is user selectable. Serial link enables to read actual readings and modify transmitter configuration. In-strument works always in slave mode, i.e. responds only to master device query.

Terminal for power and signal RS485/RS232 – for more details please see electrical wiring below on the page.

Electrical wiring of regulator with serial output RS485

Electrical wiring of regulator with serial output RS232

9 to 30V

shield shield

relay 1 relay 2

External probe

shie

ld

shield

shie

ld

shie

ld

shie

ld

shie

ld

Power from a PC port Power from an external source

Binary inputsterminals +U are connected viaan diodes to DTR and RTS terminals

LED signalization - visuali-zation of binary inputs is done by three LED diodes. Other two diodes signed as ALARM 1 and 2 show alarm state and relay

status.

shie

ld

shie

ld

shie

ld

Another device connection

relay 1 relay 2

Binary inputsterminals +U are internallyconnected to the device power supply External probe

shie

ld

shie

ld

shie

ld

shie

ld

shield

9 to 30V

Note: Sensors of concentration CO2 is not possible to power from communication port.

Page 59: COMET measuring instruments katalog

Programmable industry regulators

9

Connection of external power relay

Relay - the device is equipped with two relay outputs for alarming or controlling of external devices. It is possible to assign any input value to each relay, to set comparing limit, delay, hysteresis, acous-tic alarm or change its status by means of Modbus communication protocol.

Coil data chart of external power relay: nominal voltage : max. 50V nominal power: max. 60VA current: max. 2A

Keypad - two output relays can be configurated by means of keypad. Then any input value can be assigned, set comparing limits, hysteresis, delay or audible alarm.

Acoustic alarm – triggered alarm can be deacti-vated by pressing ”ESC”. This possibility can be disabled and the acoustic alarm is active for the duration alarm condition.

External powerrelay

Powersupply

Design - measuring elements can be integrated into the body of device or may be on the cable with lengths of up to four meters. External probe may be designed for pressure of 25 bar.

Three binary inputs – these inputs are not gal-vanic isolated, connection terminals +U are inter-nally connected to the device power supply i.e. the +U terminals provide the same voltage level as power supply.

Page 60: COMET measuring instruments katalog

Esc

Set

ALARM 2

ALARM 1

Φ18

75

Esc

Set

ALARM 2

ALARM 1

Φ 18 75

Esc

Set

ALARM 2

ALARM 1

Φ 18

155

Esc

Set

ALARM 2

ALARM 1

MEASURED VALUES temperature temperature + relative humidity temperature + relative humidity temperature + relative humidity + atm. pressure

temperature + rela-tive humidity + CO

2

C02

SENSOR MODEL WITH 2 x Relay + RS485 H4431 H0430 H3430 H3433 H3431 H3431P H7430 H7431 H6420 H5421 H5424

2 x Relay + RS232 H4331 - - - H3331 H3331P - H7331 H6320 H5321 H5324

temperaturerange -200 to +600°C -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - -

accuracy ±0,2°C (without probe) ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - -

relative humidityrange (without condensation) - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C - - ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RRH ±2,5 %RH ±2,5 %RH ±2,5 %RH - -

atm. pressurerange - - - - - - 600 to 1100hPa 600 to 1100hPa - - -

accuracy - - - - - - ±1,3 hPa ±1,3 hPa - - -

C02

range - - - - - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - - - - -

± (50ppm+2% of measured value)

± (100ppm+5% of measured value)

± (50ppm+2% of measured value)

two-state inputs YES YES YES YES YES YES YES YES NO NO NO

computed humidity values NO NO YES YES YES YES YES YES YES NO NO

supply voltage for device with relay 9-30 V 9-30 V

relay outputs max. switching voltage 50 V / max. current 2A / max. power 60VA max. switching voltage 50 V / max. current 2A / max. power 60VA

recommended calibration interval 2 years 2 years 1 year 1 year 1 year 1 year 1 year 1 year

5 years CO2/ 1 year RH / 2 years tempe-rature

5 years 5 years

protection class of the case with electronics IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 54 IP 54 IP 30 IP 65 IP 30

protection of the RH and atm. pressure /CO2 sensors - - IP 40 / - IP40/ - IP 40 / - IP 40 / - IP 40 / - IP 40 / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element - -30to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C -40 to +60°C -

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RRH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - - up to 2,5 MPa 600 to 1100hPa 600 to 1100hPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position stem downward stem downward stem downward any position any position stem downward any position stem downward any position cable gland upwards

storage temperature -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight 350 g 350 g 360 g 430 g 420 (460,540) g 470 (510, 590) g 360 g 420 (460,540) g 360 g 440 (470, 530) g 340 g

H Regulators with relay and serial output RS485/RS232

* Custom range 10 000 ppm for extra fee. Accuracy ± (100ppm+5% of measured value).

Absolute humidityAccuracy: ±1,5g/m3

at ambient temperature T < 25°C for more details see manual.Range: 0 to 400 g/m3

Dew point temperature Accuracy: ±1,5°C at ambient temperature T<25°C and relative humidity RH>30%, for more details see manual.Range: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2,1g/kg at ambienttemperature T < 35°CRange: 0 to 550 g/kg

Mixing ratioAccuracy: ±2,2g/kg at ambienttemperature T < 35°CRange: 0 to 995 g/kg

Computed humidity values

Programmable industry regulators

Page 61: COMET measuring instruments katalog

11

MEASURED VALUES temperature temperature + relative humidity temperature + relative humidity temperature + relative humidity + atm. pressure

temperature + rela-tive humidity + CO

2

C02

SENSOR MODEL WITH 2 x Relay + RS485 H4431 H0430 H3430 H3433 H3431 H3431P H7430 H7431 H6420 H5421 H5424

2 x Relay + RS232 H4331 - - - H3331 H3331P - H7331 H6320 H5321 H5324

temperaturerange -200 to +600°C -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C - -

accuracy ±0,2°C (without probe) ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - -

relative humidityrange (without condensation) - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C - - ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RRH ±2,5 %RH ±2,5 %RH ±2,5 %RH - -

atm. pressurerange - - - - - - 600 to 1100hPa 600 to 1100hPa - - -

accuracy - - - - - - ±1,3 hPa ±1,3 hPa - - -

C02

range - - - - - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - - - - -

± (50ppm+2% of measured value)

± (100ppm+5% of measured value)

± (50ppm+2% of measured value)

two-state inputs YES YES YES YES YES YES YES YES NO NO NO

computed humidity values NO NO YES YES YES YES YES YES YES NO NO

supply voltage for device with relay 9-30 V 9-30 V

relay outputs max. switching voltage 50 V / max. current 2A / max. power 60VA max. switching voltage 50 V / max. current 2A / max. power 60VA

recommended calibration interval 2 years 2 years 1 year 1 year 1 year 1 year 1 year 1 year

5 years CO2/ 1 year RH / 2 years tempe-rature

5 years 5 years

protection class of the case with electronics IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 54 IP 54 IP 30 IP 65 IP 30

protection of the RH and atm. pressure /CO2 sensors - - IP 40 / - IP40/ - IP 40 / - IP 40 / - IP 40 / - IP 40 / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case with electronics -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element - -30to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C -30 to +80°C -40 to +60°C -

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RRH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - - up to 2,5 MPa 600 to 1100hPa 600 to 1100hPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position stem downward stem downward stem downward any position any position stem downward any position stem downward any position cable gland upwards

storage temperature -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight 350 g 350 g 360 g 430 g 420 (460,540) g 470 (510, 590) g 360 g 420 (460,540) g 360 g 440 (470, 530) g 340 g

Esc

Set

ALARM 2

ALARM 1

Φ18

(150)

G1/2

HEX 19

O-ring

19

12

60

1(2

,4)

m

Esc

Set

ALARM 2

ALARM 1

(88)

1(2

,4)

m

Φ18

Esc

Set

ALARM 2

ALARM 1

(88)

1(2

,4)

m

Φ18

Φ 18 75

Esc

Set

ALARM 2

ALARM 1

Esc

Set

ALARM 2

ALARM 1

150

Φ 18.5

Esc

Set

ALARM 2

ALARM 1

Φ 18

75

Esc

Set

ALARM 2

ALARM 1

Choose the appropriate sensor model

* Custom range 10 000 ppm for extra fee. Accuracy ± (100ppm+5% of measured value).

Specific enthalpyAccuracy: ± 3kJ/kg at ambienttemperature T < 25°CRange: 0 to 995 kJ/kg

Page 62: COMET measuring instruments katalog

Programmable sensors with serial output RS485/RS232

Sensor version with watertight male connector TxxxxLFor easy connection/disconnection of the output cable is used TxxxxL version with Lumberg connector (IP67) instead of a cable gland.

The stem - a length greater than 75 mm are made of stainless

steel.

Programmable sensors and transmitters with RS232 and RS485 outputs are designed to me-asure temperature, relative humidity, baromet-ric pressure and the concentration of CO2 in non-aggressive environment. The devices are available in wall and duct mounting models or with a cable probe.

Female Lumberg connection forsensor with RS232 output

Female Lumberg connection forsensor with RS485 output

Programmable sensors with serial output without relay

T

Sensor cover with filterfrom stainless steel mesh- filtering ability 0.025mm. This cover can be replaced by a Teflon sensor cover with inc-reased resistance against spla-

shing water.

line RS485

Sensor version TxxxxD LCD display is per-pendicular to measu-ring stem.

Terminal for power and signal RS485/RS232 – for more details please see electrical wiring of sensors

page 13.

Page 63: COMET measuring instruments katalog

Transmitter circuitry is galvanically isolated from power circuitry to pre-vent collision in RS485 network.

Serial output RS232 is not galvanica-lly isolated.

The transmitter works with ModBus RTU communication protocol or with Advantech ADAM compatible proto-col. Protocol is user selectable. Serial link enables to read actual readings and modify transmitter configurati-on. Instrument works always in slave mode, i.e. responds only to master device query.

13

Electrical wiring of sensor with serial output RS485

Electrical wiring of sensor with serial output RS232

Note: Sensors of concentration CO2 is not possible to power from communication port.

LED indication - limits may be changed by user.

0 to 1000 ppm

1000 to 1200 ppm

1200to 2000/10 000 ppm

power 9 - 30V

shie

ld

shie

ld

shie

ld

shie

ld

Device I Device II

Programmable sensors with serial output without relay Industry design

Sealing lid - protection from dust and splashing water.

Measuring elements - RTD Pt1000 temperature sensor toge-ther with state-of-the-art capacitive polymer sensor ensures excellent calibration, long term stability, iner-tia against water and condensation.

Case of sensor - made of ABS which is very resistant to mechani-cal damage.

External mounting holes - easy and fast mounting without the need to take off lid cover.

Supply from communication port

red (yellow)red (brown)greenwhite

power 9 - 30V

Supply from communication port

red (yellow)red (brown)

Page 64: COMET measuring instruments katalog

Programmable sensors with serial output without relay

MEASURED VALUES temperature temperature + relative humidity temperature +

relative humidity temperature + relative humidity

+ atm. pressure atm. pressuretemperature +

relative humidity + CO

2

C02

SENSOR MODEL WITH RS485 T4411 T0410 T3411

T3413(D), T3417(D)

T3419 T3419P T7410 T7411 T2414 T6440 T5441 T5440

RS232 T4311 T0310 T3311 T3313 T3319 T3319P T7310 T7311 T2314 T6340 T5341 T5340

temperaturerange -200 to +600°C -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -

accuracy ±0,2°C (vstup bez sondy) ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - ±0,4°C - -

relative humidity

range (without condensation) - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C - - ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH - ±2,5 %RH - -

atm. pressurerange - - - - - - 600 to 1100hPa 600 to 1100 hPa 600 to 1100 hPa - - -

accuracy - - - - - - ±1,3 hPa ±1,3 hPa - - - -

C02

range - - - - - - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - - - - - -

± (50ppm+2% of measured value)

± (100ppm+5% of measured value)

± (50ppm+2% of measured value)

computed humidity values NO NO YES YES YES YES YES YES NO YES NO NO

supply voltage 9-30 Vdc 9-30 Vdc

recommended calibration interval 2 years 2 years 1 year 1 year 1 year 1 year 1 year 1 year 1 year5 years CO2/ 1 year RH / 2 years temp.

5 years 5 years

protection class of the case with electr. IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 54 IP 54 IP 54 IP 30 IP 65 IP 30

protection of the RH and atm. pressure /CO2 sensors - - IP 40 / - IP40/ - IP 40 / - IP 40 / - IP 40 / - IP 40 / - - / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element - -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C -40 to +60°C -

humidity operating range (w/o condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - - up to 2,5 MPa 600 to 1100hPa 600 to 1100hPa 600 to 1100hPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position cable gland upwards

cable gland upwards

cable gland upwards any position any position cable gland

upwards any position cable gland upwards

cable gland upwards any position cable gland

upwards

storage temperature -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight 150 g 150 g 160 g 230 g / 580 g 220 (260, 340) g 260 (300, 380) g 160 g 210 (250, 330) g 140 g 160 g 250 (280, 340) g 150 g

probe

probe

Programmable sensors with serial output RS485/RS232T

Dew point temperature Accuracy: ±1,5°C at ambient temperature T<25°C and relative humidity RH>30%, for more details see manual.Range: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2g/kg at ambienttemperature T < 35°CRange: 0 to 550 g/kg

Computed humidity values

Page 65: COMET measuring instruments katalog

15

Programmable sensors with serial output without relay

MEASURED VALUES temperature temperature + relative humidity temperature +

relative humidity temperature + relative humidity

+ atm. pressure atm. pressuretemperature +

relative humidity + CO

2

C02

SENSOR MODEL WITH RS485 T4411 T0410 T3411

T3413(D), T3417(D)

T3419 T3419P T7410 T7411 T2414 T6440 T5441 T5440

RS232 T4311 T0310 T3311 T3313 T3319 T3319P T7310 T7311 T2314 T6340 T5341 T5340

temperaturerange -200 to +600°C -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C - -

accuracy ±0,2°C (vstup bez sondy) ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C ±0,4°C - ±0,4°C - -

relative humidity

range (without condensation) - - 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH - 0 to 100 %RH - -

accuracy in range of 5 to 95% at 23°C - - ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH ±2,5 %RH - ±2,5 %RH - -

atm. pressurerange - - - - - - 600 to 1100hPa 600 to 1100 hPa 600 to 1100 hPa - - -

accuracy - - - - - - ±1,3 hPa ±1,3 hPa - - - -

C02

range - - - - - - - - - 0 to 2000 ppm* 0 to 10000 ppm 0 to 2000 ppm*

accuracy at 25°C and pressure of 1013 hPa - - - - - - - - -

± (50ppm+2% of measured value)

± (100ppm+5% of measured value)

± (50ppm+2% of measured value)

computed humidity values NO NO YES YES YES YES YES YES NO YES NO NO

supply voltage 9-30 Vdc 9-30 Vdc

recommended calibration interval 2 years 2 years 1 year 1 year 1 year 1 year 1 year 1 year 1 year5 years CO2/ 1 year RH / 2 years temp.

5 years 5 years

protection class of the case with electr. IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 54 IP 54 IP 54 IP 30 IP 65 IP 30

protection of the RH and atm. pressure /CO2 sensors - - IP 40 / - IP40/ - IP 40 / - IP 40 / - IP 40 / - IP 40 / - - / - IP 40 / IP30 - / IP 65 - / IP 30

temperature operating range of the case -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +80°C -30 to +60°C

temperature operating range of the measuring element - -30 to +80°C -30 to +80°C -30 to +125°C -30 to +105°C -30 to +105°C -30 to +80°C -30 to +105°C - -30 to +80°C -40 to +60°C -

humidity operating range (w/o condensation) 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - - - up to 2,5 MPa 600 to 1100hPa 600 to 1100hPa 600 to 1100hPa 850 to 1100hPa 850 to 1100hPa 850 to 1100hPa

mounting position any position cable gland upwards

cable gland upwards

cable gland upwards any position any position cable gland

upwards any position cable gland upwards

cable gland upwards any position cable gland

upwards

storage temperature -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C -30 to +60°C -30 to +60°C -30 to +60°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight 150 g 150 g 160 g 230 g / 580 g 220 (260, 340) g 260 (300, 380) g 160 g 210 (250, 330) g 140 g 160 g 250 (280, 340) g 150 g

Programmable sensors with serial output RS485/RS232

Industry design

* Custom range 10 000 ppm for extra fee. Accuracy ± (100ppm+5% of measured value).

Absolute humidityAccuracy: ±1,5g/m3

at ambient temperature T < 25°C for more details see manual.Range: 0 to 400 g/m3

Specific enthalpyAccuracy: ± 3kJ/kg at ambienttemperature T < 25°CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2g/kg at ambienttemperature T < 35°CRange: 0 to 995 g/kg

Page 66: COMET measuring instruments katalog

Interior design

MEASURED VALUES temperature temperature + rela-tive humidity

temperature + rela-tive humidity + atm.

pressuretemperature + C0

2

SENSOR MODEL WITH OUTPUT

RS485 T0418 T3418 T7418 T8448

RS232 T0318 T3318 T7318 -

Temperaturerange -10 to +50°C -10 to +50°C -10 to +50°C -10 to +50°C

accuracy ±0,5°C ±0,5°C ±0,5°C ±0,5°C

relative humidity

range - 5 to 95 %RH 5 to 95 %RH -

accuracy in range of 5 to 60% at 23°C - ±2,5 %RH ±2,5 %RH -

accuracy in range of 60 to 95% at 23°C - ±3 %RH ±3 %RH -

atm. pressurerange - - 600 to 1100 hPa -

accuracy - - ±1,3 hPa -

C02

range - - - 0 to 2000 ppm*

accuracy - - - ± (50ppm+2% of measured value)

computed humidity values NO YES YES NO

recommended calibration interval 2 years 1 year 1 year 2 years temperatu-re / 5 years CO2

protection class of the case with electr. IP20

temperature operating range -10 to +50°C -10 to +50°C -10 to +50°C -10 to +50°C

humidity operating range without condensation 0 to 100 %RH 0 to 100 %RH 0 to 100 %RH 5 to 95 %RH

barometric pressure operating range - - 600 to 1100hPa 850 to 1100hPa

storage temperature -30 to +80°C -30 to +80°C -30 to +80°C -30 to +80°C

electromagnetic compatibility EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1

weight 150 g 150 g 150 g 150 g

Programmable transmitters with RS232 or RS485 serial interface are designed to mea-sure temperature, relative humidity, barometric pressure and concentration CO2 in espe-cially in interiors, in building energy management and HVAC systems. They are made for easy installation in a standard way into a flush-mounted wiring box. These devices support communication protocols Modbus RTU and protocols compatible with standard Advantech-ADAM.

Programmable sensors with serial output RS485 and RS232T

* Custom range 10 000 ppm for extra fee. Accuracy ± (100ppm+5% of measured value)

Absolute humidityAccuracy: ±1,5g/m3

at ambient temperature T < 25°C for more details see manual.Range: 0 to 400 g/m3

Dew point temperature Accuracy: ±1,5°C at ambient temperature T<25°C and relative humidity RH>30%, for more details see manual.Range: -60 to +80 °C (-76 to 176 °F)

Specific humidityAccuracy: ±2g/kg at ambienttemperature T < 35°CRange: 0 to 550 g/kg

Specific enthalpyAccuracy: ± 3kJ/kg at ambienttemperature T < 25°CRange: 0 to 995 kJ/kg

Mixing ratioAccuracy: ±2g/kg at ambienttemperature T < 35°CRange: 0 to 995 g/kg

Computed humidity values

Page 67: COMET measuring instruments katalog

17

Interior design

LD-12 – water leakage

MD046 – vessel for adjustment andcalibration of humidity.

HM023 – set of humidity standards 10% RH with 5 application pads.

HM024 – set of humidity standards 80% RH with 5 application pads.

K1427 – female connector ELKA for TxxxxL transmitters with male connector Lumberg for easy connection/disconnection of the output. IP67 protection.

PP4 – plastic flat circular flange.

SP004 – plastic gland for directmounting of the humidity probeto a 29 mm diameter hole.

SH-PP – flow chamber for compressed air measurement up to 25 bar - stainless steel DIN 1.4301 inlet and outlet connection - G1/8 thread humidity probe connection - G1/2 thread screw-coupling not inclu-ded.

Protection of sensors

F8000 - solar radiation shield for transmitters with T+RH probe on the cable.

F5200 – grey sensor cover with filter from stainless steel mesh, filtering ability 0.025mm.F5200B – black sensor cover with filter from stainless steel mesh, filtering ability 0.025mm.

F5300 - teflon (PTFE) sensor cover (white colour), with increased resistance against splashing water, non-absor-bent surface, does not rust.Porous size 25μm. Temperature range -40°C to +125°C.

1 ... sampling2 ... closing valve3 ... probe4 ... flow chamber SH-PP5 ... closing valve6 ... outlet tube

JS-20 – P.I.R. motion detector is for interior protection. It detects object movement having human body temperature. The signal from the sensor is electronically analyzed. This ensures that the detector provides excellent sensi-tivity and false alarms are basica-lly eliminated.

A1510 – Ac/dc adapter 12V/450mA stabilized.

SD-280 – optical smoke detector.

SP008 – AC voltage presence sensor.

PP90 – right-angled stainless steel flange.

F0000 - sintered bronze sensor cover. Filtering ability 0.025mm.

SP009 – external probes holder for wall mounting.

MP006 – RS232/USB converter for commu-nication with the PC via USB port.

MP022 – converter USB/RS485 for USB port at the PC side which is powered from computer USB interface.

Mounting accessories

Detectors

Calibration

Power supply

Communication

Optional accessories for sensors and regulators

SA200A – magnetic door contact.

Page 68: COMET measuring instruments katalog

Comet Database also exists in 30 days trial version. So you can test it without any worries.

multiple networks

RS485

What does Comet Database offer?

» 24 hours supervision» storage place for your data » simple and clear access to your measured values» storage place for all Comet System devices» alarm SMS texts and e-mails

Comprehensive system

Comet DatabaseFor users of Web Sensors a solution for data collection to one central da-tabase is available. It is based on MS SQL or MySQL. Software system is suitable for users who want to analyze data from multiple loggers MS or other products of Comet System.

Comet Database contains many usefultools for data analysis - graphs, ta-bles, statistics, etc. Comet database also offers advanced features - se-cured access to data, accounts admi-nistration, remote monitoring, error diagnostic, database backup, etc.

Sensor RS485/232 utilityThis utility provides communicati-on between sensors with RS485/232 output and software system Comet Database. By means of this utility an unlimited number of sensors can be connected. This utility also supports multiple networks.

Sensors RS485 utility supports

» COMET sensors with serial output RS485/RS232 » 3rd party devices communicating via Modbus RTU protocol» multiple networks (can connect multiple serial communication ports)» sending data to a remote server (Comet Database can be installed on another PC)» alarm setting

Comet Database - Monitoring of temperature, relative humidity, atmospheric pressure and CO2

Page 69: COMET measuring instruments katalog

19

Basic solution

Comet Database - Monitoring of temperature, relative humidity, atmospheric pressure and CO2

Comet Database ViewerEach purchased Comet Database al-ready contains one licence of Database Viewer. This low cost browser enables several clients to view database from different places on internal network or internet. Other viewer licences can bepurchased separately for other users of Comet Database.

TSensorProgram Tsensor for sensor setting is available to download for free.

SensorReaderFreeware software for displaying and logging data from one COMET sensor.The software stores measured values-to a CSV file which can be processed in MS Excel. The software allows acous-tic signalization of exceeded limits or sensor failure.

Page 70: COMET measuring instruments katalog

Solution for Temperature Record During Transport

• record of temperature • print-out • acoustic and optical

signalization • included traceable calibration certificate • HACCP

• TÜV SÜD certified

Wireless communication with loggers via gsm

LP040 – GSM/GPRS modemMP009/1 – Antenna 3dB for modemA1940 – AC/DC adapter for modemLP002 – COM adapterQMS2901 – cable for modem setting

LP040 – GSM/GPRS modemMP009/1 – Antenna 3dB for modemLP010 – set of power cable and RS232 cable for GPRS modem connection to G0241 recorderQMS2901 – cable for modem settingMD036 – self adhesive Dual Lock for modem easy installation

KIT - GSM - L for Sxxxx, Rxxxx loggers

KIT - GSM - G for G0241 temperature recorder

COMET SYSTEM, s.r.o.1.maje 1220756 61 Roznov pod RadhostemCZECH REPUBLIC Tel: +420-571653990Fax: [email protected] Lokace:49°27‘39.94“N18°7‘51.295“E

Page 71: COMET measuring instruments katalog

Solution for Temperature Record During Transport

• record of temperature • print-out • acoustic and optical

signalization • included traceable calibration certificate • HACCP

• TÜV SÜD certified

Wireless communication with loggers via gsm

LP040 – GSM/GPRS modemMP009/1 – Antenna 3dB for modemA1940 – AC/DC adapter for modemLP002 – COM adapterQMS2901 – cable for modem setting

LP040 – GSM/GPRS modemMP009/1 – Antenna 3dB for modemLP010 – set of power cable and RS232 cable for GPRS modem connection to G0241 recorderQMS2901 – cable for modem settingMD036 – self adhesive Dual Lock for modem easy installation

KIT - GSM - L for Sxxxx, Rxxxx loggers

KIT - GSM - G for G0241 temperature recorder

COMET SYSTEM, s.r.o.1.maje 1220756 61 Roznov pod RadhostemCZECH REPUBLIC Tel: +420-571653990Fax: [email protected] Lokace:49°27‘39.94“N18°7‘51.295“E

Page 72: COMET measuring instruments katalog

* without display

» included calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard» designed for external installation on semi-trailers (models G0841,G0841W) and for installation in driver´s cabin (models G0221E, G0241)» fifteen selectable languages» record from one or two temperature probes» RS232 link for GSM modem connection – G0841, G0841W and G0241 models» selectable numerical and graphical print-out» delivery Ticket, Journey Ticket and Multi Day printouts» fast print to usual 57mm thermo paper in 10m rolls» approximately 3400 record lines/one paper roll» large graphic illuminated display» indication of temperature exceeding by LED and acoustically» record of actual or average values» USB interface for record download to the PC» calculated MKT - mean kinetic temperature for storing of pharmaceuticals in the PC program» two binary inputs for event record - door opening, fridge unit operation - G0841, G0841W and G0241 models» no need to download data - large 1MB memory stores up to 5 years of record permanently in memory» the device is powered by car electric net (9 to 32 V)» when installed, the device continuously measures and logs values. It excludes the possibility of forgetting to switch it on by the driver

TEMPERATURE RECORDERS WITH BUILT-IN PRINTERTÜV SÜD certified to conform to EN 12830, Class 1 and EN 13486, Class 1 for the transport of food

» included calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard» standard temperature sensor is Pt1000 – internal or external (up to 20 meters of length) » robust watertight case, easy installation, locking enabled» low power consumption - battery life up to 7 years, indication of remaining battery life, easy battery replacement» variability of connection to the computer - USB, RS232, Ethernet, GSM modem» permanent connection to the PC enabled, data is possible to download even during logging» models S0841, S0842 enable to combine temperature measurement with logging of contact state - e.g.door contact» dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED

TEMPERATURE RECORDERS WITHOUT BUILT-IN PRINTERTÜV SÜD certified to conform to EN 12830, Class 1 and EN 13486, Class 1 for the transport of food

* R0110 S0110 S0111 S0121 S0122 S0141 S0841 S0842

Measured Sig-nals

1xT – int 1xT – int 1xT – ext 2xT – ext 2xT - int/ext 4xT – ext 2xT - ext + 2xcontact

3xt - ext + 1xcontact

Operating tem-perature range -40 to+80°C -30 to +70°C

Accuracy of Pt1000 temperature input without probe:

±0.2°C from -50 to +100°C; ±0.2% from +100 to +260°C; ±0.4% from -90 to -50°C

Resolution: 0.1°C

Real time clock: year, leap year, month, day, hour, minute, second

Logging interval: adjustable from 10s to 24h

LCD display and alarm state refresh:

every 10 s

Total memory capacity: 32000 values in non-cyclic mode

Logging modes: non-cyclic – logging stops after filling the memory cyclic – after filling memory oldest data is overwritten by new

Dimensions without connectors:

93x64x26mm 93x64x29mm

Power: Lithium battery 3.6V, size AA

Typical battery life:

7 years 6 years 5 years

Protection: IP67 - protected against influence of temporary immersion into water

G0221E G0241 G0841 G0841W G0841M G0841MW

Measuring temperature range: -90 to +260°C

Operating temperature range: -30 to +65°C

Operating temperature range of the printer: -20 to +50°C

Compatible temperature probes: with Pt1000 sensor with maximum cable length 20 meters

Accuracy of the input without probe:

±0.2°C

Resolution: 0.1°C

Logging interval: user selectable from 1 minute to 60 minutes

Memory capacity: 1MB - 172 032 records from one probe, 102 400 records from two probes

Semitrailer version: x x Measured signals 2xT 2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact

Output for GPRS modem x x x

Built-In GPRS modem x x x x Wireless alarm unit for driver´s cabin

x x x x

Power: 9 to 32Vdc, protected against alternator load shedding+internal Lithium battery

Consumption while printing: approximately 8 W

Consumption - not printing: approximately 0.1 W approximately 0.2W

Dimensions without holders &connectors (mm) 175 x 124 x 51 250 x 242 x 110

Weight (gr): 370 1650

Protection: IP20 IP65

Android Downloader Application for COMET Data Loggers

Page 73: COMET measuring instruments katalog

* without display

» included calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard» designed for external installation on semi-trailers (models G0841,G0841W) and for installation in driver´s cabin (models G0221E, G0241)» fifteen selectable languages» record from one or two temperature probes» RS232 link for GSM modem connection – G0841, G0841W and G0241 models» selectable numerical and graphical print-out» delivery Ticket, Journey Ticket and Multi Day printouts» fast print to usual 57mm thermo paper in 10m rolls» approximately 3400 record lines/one paper roll» large graphic illuminated display» indication of temperature exceeding by LED and acoustically» record of actual or average values» USB interface for record download to the PC» calculated MKT - mean kinetic temperature for storing of pharmaceuticals in the PC program» two binary inputs for event record - door opening, fridge unit operation - G0841, G0841W and G0241 models» no need to download data - large 1MB memory stores up to 5 years of record permanently in memory» the device is powered by car electric net (9 to 32 V)» when installed, the device continuously measures and logs values. It excludes the possibility of forgetting to switch it on by the driver

TEMPERATURE RECORDERS WITH BUILT-IN PRINTERTÜV SÜD certified to conform to EN 12830, Class 1 and EN 13486, Class 1 for the transport of food

» included calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard» standard temperature sensor is Pt1000 – internal or external (up to 20 meters of length) » robust watertight case, easy installation, locking enabled» low power consumption - battery life up to 7 years, indication of remaining battery life, easy battery replacement» variability of connection to the computer - USB, RS232, Ethernet, GSM modem» permanent connection to the PC enabled, data is possible to download even during logging» models S0841, S0842 enable to combine temperature measurement with logging of contact state - e.g.door contact» dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED

TEMPERATURE RECORDERS WITHOUT BUILT-IN PRINTERTÜV SÜD certified to conform to EN 12830, Class 1 and EN 13486, Class 1 for the transport of food

* R0110 S0110 S0111 S0121 S0122 S0141 S0841 S0842

Measured Sig-nals

1xT – int 1xT – int 1xT – ext 2xT – ext 2xT - int/ext 4xT – ext 2xT - ext + 2xcontact

3xt - ext + 1xcontact

Operating tem-perature range -40 to+80°C -30 to +70°C

Accuracy of Pt1000 temperature input without probe:

±0.2°C from -50 to +100°C; ±0.2% from +100 to +260°C; ±0.4% from -90 to -50°C

Resolution: 0.1°C

Real time clock: year, leap year, month, day, hour, minute, second

Logging interval: adjustable from 10s to 24h

LCD display and alarm state refresh:

every 10 s

Total memory capacity: 32000 values in non-cyclic mode

Logging modes: non-cyclic – logging stops after filling the memory cyclic – after filling memory oldest data is overwritten by new

Dimensions without connectors:

93x64x26mm 93x64x29mm

Power: Lithium battery 3.6V, size AA

Typical battery life:

7 years 6 years 5 years

Protection: IP67 - protected against influence of temporary immersion into water

G0221E G0241 G0841 G0841W G0841M G0841MW

Measuring temperature range: -90 to +260°C

Operating temperature range: -30 to +65°C

Operating temperature range of the printer: -20 to +50°C

Compatible temperature probes: with Pt1000 sensor with maximum cable length 20 meters

Accuracy of the input without probe:

±0.2°C

Resolution: 0.1°C

Logging interval: user selectable from 1 minute to 60 minutes

Memory capacity: 1MB - 172 032 records from one probe, 102 400 records from two probes

Semitrailer version: x x Measured signals 2xT 2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact2xT + 2xcon-

tact

Output for GPRS modem x x x

Built-In GPRS modem x x x x Wireless alarm unit for driver´s cabin

x x x x

Power: 9 to 32Vdc, protected against alternator load shedding+internal Lithium battery

Consumption while printing: approximately 8 W

Consumption - not printing: approximately 0.1 W approximately 0.2W

Dimensions without holders &connectors (mm) 175 x 124 x 51 250 x 242 x 110

Weight (gr): 370 1650

Protection: IP20 IP65