clean water monitoring (cwm) - unece · clean water monitoring (cwm) development of a multi-...
TRANSCRIPT
![Page 1: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/1.jpg)
Clean Water Monitoring (CWM)
Development of a multi-parametersprobe for real-time monitoring of
water quality in networks
14.11.2016 P. Perdaems (SIG - Geneva Water) N. Giandomenico (hepia)D. Helal (Orbiwise)
![Page 2: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/2.jpg)
2
Distributor needs
Real-time Monitoring of water quality parameters
► Turbidity ► Residual Chlorine
► Conductivity ► Temperature
► Flow Velocity ► Pressure
Anticipation of pipes renewals
Hydraulic modelizationof water networks
(calculations)
Optimization of the operation of water facilities
![Page 3: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/3.jpg)
3
General Principle of CWM
Distributor :Monitoring
center
Interface
Visual Tools
- Sensors- Embedded software- Wireless communication- Protocol & Alerts- Mechanical integration
CommunicationNetwork
Probe
Drinking water network(on buried pipe)
Gateways
![Page 4: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/4.jpg)
4
A new industrial tool … innovative, universal, open & evolutive
6 physicochemicalparametersin 1 probe
Real-time measurementCompact
Directly installed in a pipe
Energy autonomy
Wireless communication & low consumption
Installation at any point of the water network
Interesting cost
► LoRaWAN® Protocol
► Diameter : 40 mm► Length : 300 mm
► Without interrupting the water distribution
► minimum 6 months► 1 standard AA battery► no electrical wire
► Production cost ≤ 1’500 $
► User settings (sampling rate)
![Page 5: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/5.jpg)
5
The Probe
![Page 6: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/6.jpg)
6
The Sensors
PARAMETERS MEASURING RANGES RESOLUTION ACCURACY
SWISS STANDARD
TurbidityRange 1 : 0.1 to 1 NTU
Range 2 : 1 to 10 NTU
0.1 ± 0.1 NTU
0.5 ± 0.5 NTU1 NTU
Residual ChlorineRange 1 : 0.01 à 0.2 mg Cl2/L
Range 2 : 0.1 à 0.5 mg Cl2/L
0.01 ± 0.01 mg Cl2/L
0.1 ± 0.1 mg Cl2/L0.1 mg Cl2/L
Temperature 0 à 30 °C 0.1 ± 0.1 °C 8 … 15°C
Flow Velocity 0 à 2 m/s 0.1 ± 0.1 m/s -
Pressure 0.1 à 16 bar 0.1 ± 0.1 bar -
Conductivity 5 à 1'000 μS/cm 5 ± 5 μS/cm 200 … 800 µS/cm
Residual Chlorine Conductivity / T°C Turbidity
![Page 7: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/7.jpg)
7
The Mechanics
![Page 8: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/8.jpg)
8
LoRAWAN™ IoT Network
LoRa™ Gateway
Cloud Application Servers
LoRaWAN™Core Network Server
User Interfaces:Network Operations & Maintenance
Users & Devices Management
![Page 9: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/9.jpg)
9
LoRAWAN™ IoT Network
End-device battery can last 10 years on one AA battery
OutdoorGateway (GW)
Device
4.5km
Typical Wireless Sensor Network
Very low cost wireless infrastructure in unlicensed bands
![Page 10: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/10.jpg)
10
LoRAWAN™ IoT Network
![Page 11: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/11.jpg)
11
Standard User Interface
Anywhere
At any time
![Page 12: Clean Water Monitoring (CWM) - UNECE · Clean Water Monitoring (CWM) Development of a multi- parameters probe for real-time monitoring of water quality in networks 14.11.2016 P. Perdaems](https://reader030.vdocuments.site/reader030/viewer/2022040912/5e86c7bb9569e1407b584301/html5/thumbnails/12.jpg)
12
Thank you
Acknowledgements