clean water monitoring (cwm) & sdg sessions/iot for clean water...clean water monitoring (cwm)...

13
Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in networks 06.06.2017 P. Perdaems (SIG - Geneva Water) N. Giandomenico (Hepia) D. Helal (Orbiwise)

Upload: others

Post on 25-Mar-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

Clean Water Monitoring

(CWM)

Development of a multi-parameters

probe for real-time monitoring of

water quality in networks

06.06.2017 P. Perdaems (SIG - Geneva Water)

N. Giandomenico (Hepia)

D. Helal (Orbiwise)

Page 2: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

2

Distributor needs

Real-time Monitoring of water quality parameters

► Turbidity ► Residual Chlorine

► Conductivity ► Temperature

► Flow Velocity ► Pressure

Anticipation of pipes renewals

Hydraulic modelizationof water networks

(calculations)

Optimization of the operation of water facilities

Page 3: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

3

General Principle of CWM

Distributor :Monitoring

center

Interface

Visual Tools

- Sensors- Embedded software- Wireless communication- Protocol & Alerts- Mechanical integration

Communication

Network

Probe

Drinking water network(on buried pipe)

Gateways

Page 4: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

4

A new industrial tool …

innovative, universal, open &

evolutive

6 physicochemicalparametersin 1 probe

Real-time measurementCompact

Directly installed in a pipe

Energy autonomy

Wireless communication & low consumption

Installation at any point of the water network

Interesting cost

► LoRaWAN® Protocol

► Diameter : 40 mm► Length : 300 mm

►Without interrupting the water distribution

►minimum 6 months► 1 standard AA battery► no electrical wire

► Production cost ≤ 1’500 $

► User settings (sampling rate)

Page 5: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

5

The Probe

Page 6: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

6

The Probe

Portes ouvertes de l’Hepia – mars 2017

Page 7: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

7

The Sensors

PARAMETERS MEASURING RANGESRESOLUTION ACCURACY

SWISS STANDARD

TurbidityRange 1 : 0.1 to 1 NTU

Range 2 : 1 to 10 NTU

0.1 ± 0.1 NTU

0.5 ± 0.5 NTU1 NTU

Residual ChlorineRange 1 : 0.01 à 0.2 mg Cl2/L

Range 2 : 0.1 à 0.5 mg Cl2/L

0.01 ± 0.01 mg Cl2/L

0.1 ± 0.1 mg Cl2/L0.1 mg Cl2/L

Temperature 0 à 30 °C 0.1 ± 0.1 °C 8 … 15°C

Flow Velocity 0 à 2 m/s 0.1 ± 0.1 m/s -

Pressure 0.1 à 16 bar 0.1 ± 0.1 bar -

Conductivity 5 à 1'000 μS/cm 5 ± 5 μS/cm 200 … 800 µS/cm

Page 8: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

8

The Sensors

Residual Chlorine Conductivity / T°C Turbidity

Page 9: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

9

LoRAWAN™ IoT Network

LoRa™ Gateway

Cloud Application

Servers

LoRaWAN™Core Network Server

User Interfaces:Network Operations & Maintenance

Users & Devices Management

Page 10: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

10

LoRAWAN™ IoT Network

▪ End-device battery can last 10 years on one AA battery

OutdoorGateway (GW)

Device

~4.5km

Typical Wireless Sensor Network

Very low cost wireless infrastructure in unlicensed bands

Page 11: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

11

LoRAWAN™ IoT Network

Page 12: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

12

Standard User Interface

Anywhere

At any time

Page 13: Clean Water Monitoring (CWM) & SDG Sessions/IoT for Clean Water...Clean Water Monitoring (CWM) Development of a multi-parameters probe for real-time monitoring of water quality in

13

Thank you

Acknowledgements