2
CLEAN MARINE - P�OD�CT SHEET Phone: +47 2104 3311 | Fax: +47 2101 4033 | Email: [email protected] www.cleanmarine.no T h e o p t i m a l E G C S s o l u t i o n f o r S O x c o m p l i a n c e The new CleanSOx Compact EGCS, through its significant size and weight reduction design allowed by the unique patented gas recirculation technology , brings maritime scrubbers to the next level. The compact size of this scrubber does therefore not necessitate or involve a major design change or rebuilding of a vessels to fit the equipment onboard. The CleanSOx Compact scrubber represents the optimal solution for owners opting for scrubbers when considering parameters like: hybrid, Allstream, Size, Weight, Design and the Total Cost to have it installed and commissioned. The patented CleanSOx EGCS is designed to meet the needs of the maritime industry and offers proven Allstream exhaust gas handling meaning all exhaust sources on board can be served by one common EGCS unit; enabling a fast return on investment. Our EGCS systems works equally well in open (liquid one time through) and closed (liquid recirculation) modes while seawater and alkali is used to regulate the sulphur trapping efficiency in both modes. The EGCS can operate in all types of water (including low alkaline and saline water) in either mode and without loss of efficiency. The CleanSOx EGCS is therefore an optimal solution for the marine environment and represents a futureproof system for the ship owner, adhering to regulatory variety in all waters. Our system has also the ability to combine natural and added alkalinity in open loop operation. This means it will provide high cleaning efficiency while maintaining a pH>6 at the outlet, making the effluent compliant with all IMO and regional/local regulations. The CleanSOx Compact EGCS are tailor made too any engine size and vessel. More details to be found on page 2. K e y f e a t u r e s N o b a c k p r e s s u r e : No fuel penalty AE’s can start connected to EGC unit(s) No restrictions running AE’s in part load – no impact on - engine parameters (EIAPP) Boilers connected C l o s e d l o o p / o p e n l o o p o p e r a t i o n : - Open loop 0,5% Sulphur – sea water only when Sulphur < 3,5% Open loop 0,1% Sulphur – sea water + NaOH dosing; can transit any water – no alkalinity restrictions Closed loop – sea water + NaOH dosing; only required - where zero discharge is called for p H : Open loop 0,5% Sulphur – process water + cooling water + dilution device Open loop 0,1% Sulphur – plus NaOH (pH 6,5 at 4m or pH 6 - overboard) B e n e f i t s One Fuel, All sources, All waters, All time

Upload: others

Post on 14-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CLEAN MARINE - CASE STUDY P OD CT SHEET CHEMICAL …€¦ · through) and closed (liquid recirculation) modes while seawater andswitchboard, PLC, Documentation and Certification,

CLEAN MARINE - P�OD�CT SHEET

Phone: +47 2104 3311 | Fax: +47 2101 4033 | Email: [email protected]

www.cleanmarine.no

The optimal EGCS solution for SOx

compliance The new CleanSOx Compact EGCS, through its significant size and

weight reduction design allowed by the unique patented gas

recirculation technology , brings maritime scrubbers to the next level.

The compact size of this scrubber does therefore not necessitate or

involve a major design change or rebuilding of a vessels to fit the

equipment onboard. The CleanSOx Compact scrubber represents the

optimal solution for owners opting for scrubbers when considering

parameters like: hybrid, Allstream, Size, Weight, Design and the Total

Cost to have it installed and commissioned.

The patented CleanSOx EGCS is designed to meet the needs of the

maritime industry and offers proven Allstream exhaust gas handling

meaning all exhaust sources on board can be served by one common

EGCS unit; enabling a fast return on investment.

Our EGCS systems works equally well in open (liquid one time

through) and closed (liquid recirculation) modes while seawater and

alkali is used to regulate the sulphur trapping efficiency in both

modes. The EGCS can operate in all types of water (including low

alkaline and saline water) in either mode and without loss of

efficiency.

The CleanSOx EGCS is therefore an optimal solution for the marine

environment and represents a futureproof system for the ship owner,

adhering to regulatory variety in all waters. Our system has also the

ability to combine natural and added alkalinity in open loop operation.

This means it will provide high cleaning efficiency while maintaining a

pH>6 at the outlet, making the effluent compliant with all IMO and

regional/local regulations.

The CleanSOx Compact EGCS are tailor made too any engine size and

vessel. More details to be found on page 2.

Key features

No back pressure:

• No fuel penalty

• AE’s can start connected to EGC unit(s)

• No restrictions running AE’s in part load – no impact on

- engine parameters (EIAPP)

• Boilers connected

Closed loop/open loop operation:

-

Open loop 0,5% Sulphur – sea water only when

Sulphur < 3,5%

Open loop 0,1% Sulphur – sea water + NaOH dosing; can

transit any water – no alkalinity restrictions

• Closed loop – sea water + NaOH dosing; only required

- where zero discharge is called for

pH :

• Open loop 0,5% Sulphur – process water + cooling water +

dilution device

• Open loop 0,1% Sulphur – plus NaOH (pH 6,5 at 4m or pH 6

- overboard)

BenefitsOne Fuel, All sources, All waters, All time

GENERAL DESCRIPTION

NameSpring Ploeg

TypeChemical tanker

OwnerHansa Tankers

ClassClass NK

Yard-

Vessel delivery-

Delivery ofequipmentJune 2017

Imo. No.9774707

FlagCayman Islands

Deadweight19.900 dwt

SERVING THE FOLLOWING EXHAUST PRODUCING MACHINERIES1 x ME, 4440 kW

3xAE, 560 kW

1xAB, 15 ton/h

MAJOR SCOPE

EGC unit complete with fan and 5 exhaust gas connections, pumps with variable frequency drive, filters, cooler, NaOH dosage system, gas (SO2/CO2) and water  (PAH , turbidity, pH, flow) analyzers, temperature and pressure monitoring, valves, flow meters, exhaust dampers (bypass), switchboard, PLC, Documentation and Certification, Services during planning, installation and commissioning.

DIMENSIONS & WEIGHT OF THE EGC UNIT HANDLING 60.000 KG EXHAUST/HOURHeight (H)4,7 m

Width (W)5,3 m

Depth (D)3,8 m

Weight11 mt

Water flow270 m3/h

El. power req.Max. 79 kW in open loop and 84 kW in closed loop (1,5-2% of load)

SCRUBBER DETAILS

HYBRID (OPEN & CLOSED LOOP)

ONE SINGLE ALLSTREAM EGC UNIT

CHEMICAL TANKERCLEAN MARINE - CASE STUDY

HANSA TANKERS

Phone: +47 2104 3311 | Fax: +47 2101 4033 | Email: [email protected]

www.cleanmarine.no

Page 2: CLEAN MARINE - CASE STUDY P OD CT SHEET CHEMICAL …€¦ · through) and closed (liquid recirculation) modes while seawater andswitchboard, PLC, Documentation and Certification,

1 1

2 2

3 3

4 4

5 5

6 6

AA

BB

CC

DD

Conf

iden

tial.

This d

rawing

and

the

info

rmat

ion

cont

aine

d is the

exc

lusive

pro

perty

of C

lean

Marin

e AS

and

sha

ll no

t be

cop

ied

or m

ade

available

to o

ther

s with

out a

writt

en con

sent

.ww

w.clea

nmar

ine.no

REAS

ON F

OR IS

SUE

DRAW

ING

NO.

PROJ

ECT

NO.

REVISION

SHEE

T SIZE

SHEE

T NO

.

4A3

1 of

1

Issu

ed for

info

rmat

ion

Clea

nSOx

Com

pact

EGC-

unit

typica

l dime

nsions

1700

0-20

000-

001

FIRS

T AN

GLE

PROJ

ECTION

HULL

NO.

PREL

IMIN

ARY

Note

s.1.

Exha

ust an

d wa

ter inte

rfac

es can

be

rota

ted

acco

rding

acco

rding

to clie

nt req

uest

.2. C

ommo

n inlet fo

r all ex

haus

t so

urce

s. W

hen

more

tha

n on

e ex

haus

t so

urce

s ar

e co

nnec

ted

to

the

EGCS

, the

y ar

e fir

st rou

ted

thro

ugh

an e

xhau

st g

as m

anifo

ld.

428

.11.2017

OHW

Upda

teTA

M3

17.10

.2017

LPUp

date

TAM

212.09.20

17LP

Upda

teTA

M1

27.07.20

17LP

Firs

t issu

eTA

MRE

VDA

TEMA

DE B

YDE

SCRIPT

ION

APPR

Typica

l va

lues

Syst

em s

ize

6070

8090

100

120

140

160

180

200

220

Height

[m]

4,5

4,7

5,1

5,2

5,5

6,0

6,3

6,7

7,0

7,4

7,6

Width

[m]

5,3

5,4

5,9

6,0

6,5

7,2

7,4

8,1

8,3

9,0

9,4

Dept

h [m

]3,9

4,1

4,4

4,6

5,0

5,4

5,7

6,1

6,3

6,9

7,1

Dry

mass

[me

tric

ton]

9,1

10,2

11,7

12,8

14,5

17,2

19,4

22,2

24,4

27,5

29,9

Exha

ust fa

n

Exha

ust inlet

Sea

wate

r inlet

Was

h wa

ter dr

ain

Height

Was

h wa

ter dr

ain

Depth

Width

Sea

wate

r inlet

Clea

ned

Exha

ust ou

tlet