civil site development commercial

11
5/31/2015 To whom it may concern, Please find attached my Topography drafting/design portfolio for your review. I completed the attached work using Civil3D in spring 2015. The following plans include: - Site Rendering - Initial Land Plot - Surface Elevation Grading - Slope Grading - Tree Protection Plan - Demolition Plan - Dimensioning Plan - Site Improvements Plan - Proposed Elevation Grading Plan - Utility Plan Please feel free to contact me with any questions. Thank you for your consideration and I look forward to speaking with you, Matthew Dailey 512-680-7028 [email protected]

Upload: matthew-dailey

Post on 14-Aug-2015

20 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Civil Site Development Commercial

5/31/2015 To whom it may concern, Please find attached my Topography drafting/design portfolio for your review. I completed the attached work using Civil3D in spring 2015. The following plans include:

- Site Rendering - Initial Land Plot - Surface Elevation Grading - Slope Grading - Tree Protection Plan - Demolition Plan - Dimensioning Plan - Site Improvements Plan - Proposed Elevation Grading Plan - Utility Plan

Please feel free to contact me with any questions. Thank you for your consideration and I look forward to speaking with you, Matthew Dailey 512-680-7028 [email protected]

Page 2: Civil Site Development Commercial
Page 3: Civil Site Development Commercial

N

3

0

°

5

5

'

3

5

"

E

3

4

0

.

0

0

'

N

5

9

°

1

8

'

3

1

"

W

1

3

3

.

5

4

'

S

3

0

°

4

6

'

5

9

"

W

1

2

3

.

7

6

'

N

3

0

°

5

5

'

3

5

"

E

1

9

9

.

1

3

'

S

5

9

°

0

4

'

2

5

"

E

2

4

9

.

3

1

'

1

0

'

P

.

U

.

E

.

1

0

'

P

.

U

.

E

.

2

5

'

B

.

L

.

2

5

'

B

.

L

.

S

5

9

°

0

4

'

2

5

"

E

2

0

5

.

7

2

'

C

1

C

2

C

3

C

4

M

E

T

R

I

C

B

L

V

D

(

1

0

0

'

R

.

O

.

W

.

)

P

A

R

M

E

R

L

N

.

(

1

5

0

'

R

.

O

.

W

.

)

LOT 1

1.53 A

CR

ES

LOT 2

1.02 A

CR

ES

DRAWN BY:

SHEET

EN

TE

R D

RA

WIN

G T

IT

LE

H

ER

E

??

E

NT

ER

Y

OU

R P

RO

JE

CT

N

AM

E H

ER

E ?

?

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

YOUR NAME

1of1

0

SCALE: 1" =

1"

?'

A & E CAD SUBDIVISION

STATE OF TEXAS

COUNTY OF TRAVIS

KNOW ALL MEN BY THESE PRESENTS THAT I, MATTHEW DAILEY,

OWNER OF THAT CERTAIN 2.55 ACRE TRACT CONVEYED TO ME IN

VOLUME 123, PAGE 456, OF THE DEED RECORDS OF TRAVIS COUNTY,

TEXAS, DO HEREBY SUBDIVIDE 2.55 ACRES OF SAID TRACT IN

ACCORDANCE WITH THE ATTACHED PLAT, TO BE KNOWN AS NEW

LAND SUBDIVISION, SECTION 2, AND DEDICATED TO THE PUBLIC USE,

THE STREETS AND EASEMENTS SHOWN THEREON.

A. STUDENT DATE

Page 4: Civil Site Development Commercial

DRAWN BY:

SHEET

EL

EV

AT

IO

N B

RA

ND

IN

G M

AP

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

Page 5: Civil Site Development Commercial

DRAWN BY:

SHEET

SL

OP

E M

AP

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

?'

Page 6: Civil Site Development Commercial

DRAWN BY:

SHEET

TR

EE

P

RO

TE

CT

IO

N P

LA

N

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

CHAIN LINK FENCE

DRIPLINE (VARIES)

CRITICAL ROOT ZONE

DRIPLINE

TREE PROTECTION FENCE

FENCE LOCATION

CITY OF AUSTIN

STANDARD NO.

ADOPTED

THE ARCHITECT/ENGINEER ASSUMES

RESPONSIBILITY FOR APPROPRIATE USE

OF THIS STANDARD.

TREE PROPTECTION FENCE

TYPE A - CHAIN LINK

610S-2

1.5 m

(5'-0'')

(LIMITS OF CRITICAL ROOT ZONE)

RADIUS=12 mm PER mm (1 ft PER in)

OF TRUNK DIAMETER

6.O m FOR

500 mm DIA. TREE

(20'-0'' FOR

20'' DIA. TREE)

WATERSHED PROTECTION DEPARTMENT

3 m (10'-0'')

MAX.

11/15/99

RECORD COPY SIGNED

BY J. PATRICK MURPHY

NOTES:

641S-1

EXISTING GRADE

R.O.W.

ROADWAY

STABILIZED CONSTRUCTION ENTRANCE

PLAN VIEW

PROFILE

CITY OF AUSTIN

STANDARD NO.

ADOPTED

WATERSHED PROTECTION DEPARTMENT

CITY OF AUSTIN

THE ARCHITECT/ENGINEER ASSUMES

RESPONSIBILITY FOR APPROPRIATE USE

OF THIS STANDARD.

15 m

(50') MIN.

GRADE TO PREVENT RUNOFF

FROM LEAVING SITE

200 mm

(8'') MIN.

PROVIDE APPROPRIATE TRANSITION

BETWEEN STABILIZED CONSTRUCTION

ENTRANCE AND PUBLIC RIGHT-OF-WAY

15 m

(50') MIN.

1. STONE SIZE: 75-125 mm (3-5'') OPEN GRADED ROCK.

2. LENGTH: AS EFFECTIVE BUT NOT LESS THAN 15 m (50').

3. THICKNESS: NOT LESS THAN 200 mm (8'').

4. WIDTH: NOT LESS THAN FULL WIDTH OF ALL POINTS OF INGRESS/EGRESS.

7. DRAINAGE: ENTRANCE MUST BE PROPERLY GRADED OR INCORPORATE A DRAINAGE

SWALE TO PREVENT RUNOFF FROM LEAVING THE CONSTRUCTION SITE.

5. WASHING: WHEN NECESSARY, VEHICLE WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT

PRIOR TO ENTRANCE ONTO PUBLIC ROADWAY. WHEN WASHING IS REQUIRED, IT SHALL

BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE AND DRAINS INTO AN APPROVED

TRAP OR SEDIMENT BASIN. ALL SEDIMENT SHALL BE PREVENTED FROM ENTERING ANY

STORM DRAIN, DITCH OR WATERCOURSE USING APPROVED METHODS.

6. MAINTENANCE: THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL

PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC ROADWAY. THIS MAY

REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND, AS

WELL AS REPAIR AND CLEAN OUT OF ANY MEASURE DEVICES USED TO TRAP SEDIMENT.

ALL SEDIMENTS THAT IS SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC

ROADWAY MUST BE REMOVED IMMEDIATELY.

5/23/00

RECORD COPY SIGNED

BY J. PATRICK MURPHY

SF

L=

642S-1

SILT FENCE

TRENCH CROSS SECTION

150 mm

(6'') MIN.

150 mm

(6'') MIN.

TRENCH (BACKFILLED)

FABRIC TOE-IN

GEOTEXTILE FABRIC

F

L

O

W

STEEL FENCE POSTS

MAX. 1.8 m (6') SPACING

WOVEN WIRE SUPPORT

10.1 mm DIA. WIRE

(12 GA. WIRE)

NET BACKING

600 mm

(24'')

3. THE TRENCH MUST BE A MINIMUM OF 150 mm (6 inches) DEEP AND 150 mm

(6 inches) WIDE TO ALLOW FOR THE SILT FENCE FABRIC TO BE LAID IN THE GROUND

AND BACKFILLED WITH COMPACTED MATERIAL.

4. SILT FENCE SHOULD BE SECURELY FASTENED TO EACH STEEL SUPPORT POST OR

TO WOVEN WIRE, WHICH IS IN TURN ATTACHED TO THE STEEL FENCE POST.

5. INSPECTION SHALL BE MADE WEEKLY OR AFTER EACH RAINFALL EVENT AND REPAIR

OR REPLACEMENT SHALL BE MADE PROMPTLY AS NEEDED.

6. SILT FENCE SHALL BE REMOVED WHEN THE SITE IS COMPLETELY STABILIZED SO AS

NOT TO BLOCK OR IMPEDE STORM FLOW OR DRAINAGE.

NOTES:

1. STEEL POSTS WHICH SUPPORT THE SILT FENCE SHALL BE INSTALLED ON A SLIGHT

ANGLE TOWARD THE ANTICIPATED RUNOFF SOURCE. POST MUST BE EMBEDDED

A MINIMUM OF 300 mm (1'').

CITY OF AUSTIN

STANDARD NO.

ADOPTED

WATERSHED PROTECTION DEPARTMENT

CITY OF AUSTIN

THE ARCHITECT/ENGINEER ASSUMES

RESPONSIBILITY FOR APPROPRIATE USE

OF THIS STANDARD.

STANDARD SYMBOL

FOR SILT FENCE (SF)

2. THE TOE OF THE SILT FENCE SHALL BE TRENCHED IN WITH A SPADE OR

MECHANICAL TRENCHER, SO THAT THE DOWNSLOPE FACE OF THE TRENCH IS FLAT

AND PERPENDICULAR TO THE LINE OF FLOW. WHERE FENCE CAN NOT BE TRENCHED

INTO THE SURFACE (E.G. PAVEMENT), THE FABRIC FLAP SHALL BE WEIGHTED DOWN

WITH WASHED GRAVEL ON UPHILL SIDE TO PREVENT FLOW UNDER FENCE.

7. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH OF 150 mm

(6 inches). THE SILT SHALL BE DISPOSED OF ON AN APPROVED SITE AND IN SUCH A

MANNER THAT WILL NOT CONTRIBUTE TO ADDITIONAL SILTATION.

5/23/00

RECORD COPY SIGNED

BY J. PATRICK MURPHY

0

SCALE: 1" =

1"

40'

Page 7: Civil Site Development Commercial

DRAWN BY:

SHEET

DE

MO

LIT

IO

N P

LA

N

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

Page 8: Civil Site Development Commercial

DRAWN BY:

SHEET

DIM

EN

SIO

N P

LA

N

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

Page 9: Civil Site Development Commercial

DRAWN BY:

SHEET

SIT

E IM

PR

OV

EM

EN

TS

P

LA

N

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

Page 10: Civil Site Development Commercial

DRAWN BY:

SHEET

PR

OP

OS

ED

G

RA

DIN

G P

LA

N

TA

CO

'S

S

HO

P

AU

ST

IN

C

OM

MU

NIT

Y C

OL

LE

GE

- D

FT

G 2

43

0

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

GRADING LEGEND

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

PROPOSED CONTOUR MAJOR

PROPOSED CONTOUR MINOR

600

600

PROPOSED SPOT ELEVATION

x 600.00

PROPOSED DRAINAGE ARROW

Page 11: Civil Site Development Commercial

N

2

8

°

2

7

'

4

8

"

E

3

4

0

.

0

0

'

N

6

1

°

3

2

'

1

2

"

W

2

0

5

.

7

2

'

N

6

1

°

4

6

'

0

7

"

W

1

3

3

.

5

4

'

S

2

8

°

1

9

'

1

2

"

W

1

2

3

.

7

6

'

M

E

T

R

I

C

B

L

V

D

.

P

A

R

M

E

R

L

N

.

1

0

'

P

.

U

.

E

.

1

0

'

P

.

U

.

E

.

2

5

'

B

.

L

.

2

5

'

B

.

L

.

C

4

C

3

C

2

C

1

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

L

W

W

DRAWN BY:

SHEET

UT

IL

IT

Y P

LA

N

TA

CO

'S

S

HO

P

AC

C - A

RC

HIT

EC

TU

RA

L &

E

NG

IN

EE

RIN

G C

AD

D

EP

AR

TM

EN

T

MATT DAILEY

1of1

0

SCALE: 1" =

1"

40'

WW

GAS

WL

OHE

WW

GAS

WL