Cherenkov Detector for Beam Quality Measurement A. E. Dabrowski 1 , R.Loos 1 , S. S. Orfanelli 1,2 , J.Mans 3 , R. Rusack 3 , K. S?@er 3 , D. P. S?ckland 4 , F. Fabbri 5 , A. Montanari 5 , N.Tosi 5 1. CERN, 2. Na?onal Technical University of Athens, 3. University of Minnesota, 4.Princeton University, 5. INFN Bologna

Upload: others

Post on 27-May-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cherenkov Detector for Beam Quality Measurement · • Since Cherenkov radiation is emitted in a forward cone around the charged particle’s trajectory, BHM can distinguish the low

Cherenkov Detector for Beam Quality Measurement  

A.  E.  Dabrowski1,  R.Loos1,  S.  S.  Orfanelli1,2,  J.Mans3,  R.  Rusack3,  K.  S?@er3,  D.  P.  S?ckland4,  F.  Fabbri5,  A.  Montanari5,  N.Tosi5  

1.  CERN,  2.  Na?onal  Technical  University  of  Athens,  3.  University  of  Minnesota,  4.Princeton  University,  5.  INFN  Bologna    

Page 2: Cherenkov Detector for Beam Quality Measurement · • Since Cherenkov radiation is emitted in a forward cone around the charged particle’s trajectory, BHM can distinguish the low

Beam  Halo  Monitor  in  CMS:    novel,  fast  &  direc8onal    

•  Beam Halo Monitor (BHM) is a new monitor to measure online bunch-by-bunch beam background in the CMS experiment at LHC.

•  BHM will provide feedback to the LHC about the beam quality. •  Since Cherenkov radiation is emitted in a forward cone around the charged

particle’s trajectory, BHM can distinguish the low rate of machine induced background from collision products.    

backward   forward  

Page 3: Cherenkov Detector for Beam Quality Measurement · • Since Cherenkov radiation is emitted in a forward cone around the charged particle’s trajectory, BHM can distinguish the low

Installa8on  &  first  beams  results  

Time [UTC+2:00]12:57:00

12:59:3013:02:00

13:04:3013:07:00

13:09:3013:12:00

13:14:3013:17:00

13:19:3013:22:00

13:24:3013:27:00

13:29:3013:32:00

13:34:3013:37:00

13:39:3013:42:00

13:44:30

Aver

age

Rate

per

cha

nnel

[Hz]

0

2

4

6

8

10

12

14

(Fill 3679, 5 May 2015)

Verti

cal C

ollim

ator

Gap

[mm

]

0

5

10

15

20

25

30+Z BHM rate

-Z BHM ratebeam 1 collimator

beam 2 collimator

(Fill 3679, Circulating Beams, 5 May 2015)!

Aver

age

Rat

e pe

r cha

nnel

[Hz]

Verti

cal C

ollim

ator

gap

[mm

]

The  increase  in  BHM  rate  occurs,  as  expected,  when  the  collimator  gap  is  reduced.  

The  BHM  units  in  blue  as  installed  parallel  to  the  beam  pipe  around  the  CMS  rota=ng  shielding  at  radius  ~180  cm  from  beam  pipe,  20.6  m  from  IP.  Twenty  detectors  were  installed  per  end.    

The  BHM  units  in  blue  as  installed  parallel  to  the  beam  pipe  around  the  CMS  rota=ng  shielding  at  radius  ~180  cm  from  beam  pipe,  20.6  m  from  IP.