Open-Loop Control

• Process control operations are performed automatically by either open-loop or closed-loop systems

• Processes controlled only by set-point commands without feedback are open-loop

• Open-loop systems are used in applications where simple processes are performed

• Open-loop systems are relatively inexpensive

Page 3: Ch16 - Process Control

Chapter 15 - Process Control Methods

3

Closed-Loop Control

• Closed-loop control systems are more effective than open-loop systems

• With the addition of a feedback loop they become self-regulating

• Components of a closed-loop system include:– The primary element - sensor

– The controlled variable

– The measured variable

– The control signal

– The final correcting element

Page 4: Ch16 - Process Control

Chapter 15 - Process Control Methods

4

Process Behavior

• The objective of process control is to cause a controlled variable to remain at a constant value at or near some desired set-point

• The controlled variable changes because of:– A disturbance appears– Load demands vary– Set points are adjusted

Page 5: Ch16 - Process Control

Chapter 15 - Process Control Methods

5

Process Behavior Example

• Flow through the pipe is the process

• Fluid flow rate is the controlled variable

• Valve position is the set point

• Demand for the fluid downstream is the load

• Variance in upstream pressure is the disturbance

Page 6: Ch16 - Process Control

Chapter 15 - Process Control Methods

6

Single-Variable Control Loop• Several process variables are controlled at once in a typical

production machine• Usually, only one individual feedback loop is required to

control each variable• Single-variable control loops consist of the following elements:

– Measuring device– Transducer/transmitter– Controller– Final Control Element

Page 7: Ch16 - Process Control

Chapter 15 - Process Control Methods

7

Response Time of the Instrument• All instruments have a

time lag - the time from when a variable is measured till the corrective action is taken

• Factors affecting lag:– Response time of sensor– Time lag of transducer– Distance the signal must travel– Time required for the

controller to process – Distance control signal must

travel– Time lag of the final

correcting element

Page 8: Ch16 - Process Control

Chapter 15 - Process Control Methods

8

Time Lag

• The controlled variable itself may contribute to lag problems because of inertia in the variable

• Lag due to inertia of the variable is referred to as pure lag

• Another factor that affects time lag is dead time - this is the elapsed time from when the deviation occurs and corrective action takes place

Page 9: Ch16 - Process Control

Chapter 15 - Process Control Methods

9

Illustration of Pure Lag

Page 10: Ch16 - Process Control

Chapter 15 - Process Control Methods

10

Selecting a Controller

• The controller mode selection is based upon the requirements of the process and one of the following control modes will be used:– On/Off– Proportional– Integral– Derivative

Page 11: Ch16 - Process Control

Chapter 15 - Process Control Methods

11

On-Off Control• Used for slow acting operations

where lag is unavoidable• Final correcting element is either

fully-on or fully-off• The primary drawback of on-off

control is the rapid switching of the final control element

• On-off differential or hysteresis is programmed into the controller

• Deadband refers to the differing levels at which a controller switches on and off

Page 12: Ch16 - Process Control

Chapter 15 - Process Control Methods

12

Continuous Control

• On/Off control is acceptable for process where the variable is set between two limits

• For processes where the variable needs to be kept at particular setpoint level, proportional control is used

• Proportional action can be accomplished in two ways:– Time Proportioning Method

– Amplitude Proportional Method

Page 13: Ch16 - Process Control

Chapter 15 - Process Control Methods

13

Time Proportioning

• Is a method whereby the output of the controller is continually switched on and off

• On versus off times are varied dependent upon process requirements

Page 14: Ch16 - Process Control

Chapter 15 - Process Control Methods

14

Amplitude Proportional

• Most common technique to produce a proportional signal

• The control signal is proportional in amplitude to the error signal

• The signal may be amplified and the amplification may be referred to as proportional gain and proportional band

Page 15: Ch16 - Process Control

Chapter 15 - Process Control Methods

15

Proportional Gain Comparison

Level control at a gain of 1

Page 16: Ch16 - Process Control

Chapter 15 - Process Control Methods

16

Proportional Gain

Comparison (Gain set at 2)

Page 17: Ch16 - Process Control

Chapter 15 - Process Control Methods

17

Proportional Band

• Proportional band is defined as the percentage change in the controlled variable that causes the final correcting element to go through 100 percent of its range

PB = Controlled Variable % Change

Final Correcting Element % Change

Page 18: Ch16 - Process Control

Chapter 15 - Process Control Methods

18

Integral Control

• Because of the introduction of offset in a control process, proportional control alone is often used in conjunction with Integral control

• Offset is the difference between set point and the measured value after corrective action has taken place

Page 19: Ch16 - Process Control

Chapter 15 - Process Control Methods

19

Reset Action• Integral control is also referred to

as reset control as the set point is continuously reset as long as an error is present

• Integral adjustments that affect the output are labeled 3 ways:

– Gain - expressed as a whole number

– Reset - Expressed in repeats per minute

– Integral Time - Expressed in minutes per reset

Page 20: Ch16 - Process Control

Chapter 15 - Process Control Methods

20

Derivative Mode• For rapid load changes, the

derivative mode is typically used to prevent oscillation in a process system

• The derivative mode responds to the rate of change of the error signal rather than its amplitude

• Derivative mode is never used by itself, but in combination with other modes

• Derivative action cannot remove offset

Page 21: Ch16 - Process Control

Chapter 15 - Process Control Methods

21

Control Mode Summary

Page 22: Ch16 - Process Control

Chapter 15 - Process Control Methods

22

Tuning the Controller

• Fine-tuning is the process to optimize the controller operation by adjusting the following settings:– Gain setting (proportional mode)– Reset rate (integral mode)– Rate (derivative mode)

• Three steps are taken when tuning a systems– Study the control loop– Obtain clearance for tuning procedures– Confirm the correction operation of the system components

Page 23: Ch16 - Process Control

Chapter 15 - Process Control Methods

23

Trial-and-Error Tuning

• Does not use mathematical methods, instead a chart recorder is used and several bump tests are made in the proportional and integral modes

• Trial-and-error tuning is very time consuming and requires considerable experience on the part of the technician or operator

Page 24: Ch16 - Process Control

Chapter 15 - Process Control Methods

24

Ziegler-Nichols Tuning Methods

• Two formal procedures for tuning control loops:– Continuous cycling method

– Reaction curve method

Page 25: Ch16 - Process Control

Chapter 15 - Process Control Methods

25

Continuous Cycling Method

• The continuous cycling method analyzes the process by forcing the controlled variable to oscillate in even, continuous cycles

• The time duration of one cycle is called an ultimate period. The proportional setting that causes the cycling is called the ultimate proportional value

• These two values are then used in mathematical formulas to calculate the controller settings

Page 26: Ch16 - Process Control

Chapter 15 - Process Control Methods

26

Continuous Cycle Calculations• Proportional only controller• Proportional Gain

– Kc = Gu x 0.5 • KC = proportional gain, • Gu= ultimate gain

• Proportional Band– PB = Pbu x 2

• PB = proportional band• Pbu = ultimate proportional band

Page 27: Ch16 - Process Control

Chapter 15 - Process Control Methods

27

Continuous Cycling Formulas

Page 28: Ch16 - Process Control

Chapter 15 - Process Control Methods

28

Ziegler-Nichols Reaction Curve Tuning Method

• This method avoids the forced oscillations that are found in the continuous cycle tuning method

• Cycling should be avoided if the process is hazardous or critical

• This method uses step changes and the rate at which the process reacts is recorded

• The graph produces three different values used in mathematical calculations to determine the proper controller settings

Page 29: Ch16 - Process Control

Chapter 15 - Process Control Methods

29

Reaction Curve Tuning Formulas

Page 30: Ch16 - Process Control

Chapter 15 - Process Control Methods

30

Direct Synthesis Method• The direct synthesis method uses the

same procedures to analyze the process times as the Ziegler-Nichols reaction curve method

• One advantage of this method is that it directly matches (synthesizes) synthesizes the process

• The first step in this method is perform a bump test and recording the dynamic settling time

• Depending upon the complexity of the process, one of several dynamic response signals may develop as shown on the right

Page 31: Ch16 - Process Control

Chapter 15 - Process Control Methods

31

Direct Synthesis Tuning Calculations

Page 32: Ch16 - Process Control

Chapter 15 - Process Control Methods

32

Advanced Control Techniques• Some complex manufacturing operations require

more precise control than available with PID controllers

• Four Techniques frequently used are:– Cascade control– Feed forward control– Ratio control– Adaptive control

Page 33: Ch16 - Process Control

Chapter 15 - Process Control Methods

33

Cascade Control

• Cascade control systems use a second feedback loop with a separate sensor and controller

• Cascade control is effective in overcoming lag in some systems

Page 34: Ch16 - Process Control

Chapter 15 - Process Control Methods

34

Feedforward Control

• Feedforward control measures a variable that enters a process and takes corrective action if it is affected by a disturbance, reducing or eliminating deviation from the set point

Page 35: Ch16 - Process Control

Chapter 15 - Process Control Methods

35

Ratio Control

• Used in mixing systems where an uncontrolled flow of material (wild flow) is monitored and used to control the second material which is controlled according to the desired ratio between the two components

Page 36: Ch16 - Process Control

Chapter 15 - Process Control Methods

36

Adaptive Control

• To accommodate a nonlinear process, a microelectronic controller uses software that has adaptive control capabilities to compensate for nonlinear transducers and sensors