www.cdvi.ca Input 1 1K Ohm Input 2 2.2K Ohm EOL 1K Ohm Optional Loop Supervision + - + - + - + - + - + - ! GND A+ B - GND A1+ B1 - +12V GND A2+ B2 - + - OPTION 1: Local Connections OPTION 2: Dial-up Connection OPTION 3: TCP/IP Connection S YSTEM O VERVIEW Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules: Pro-Report with Tracker: On demand, scheduled or customized reports FrontView: Live interactive floor plans FrontGuard: Display real-time visual authentication FrontCard: Create, modify, delete and print cards, include Photo-ID Locator: Monitor real-time location of each card holder WavePlayer: Play a sound on any system event Workstation license (CS-WSLIC): Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules. LITE CS-AC-LITE Standard CS-AC-STD Professional CS-AC-PRO** Enterprise CS-AC-ENT** Sites 1 64 64 64 Serial Ports 1 1 1 4 Dial Up - Yes Yes Yes TCP/IP - Yes Yes Yes Cards* 512 2,048 8,196 16,384 Controllers* 16 32 64 256 Doors* 16 128 512 2048 * Per site ** Comes with a workstation license LCD Display CK-TRAK-L (Max. 8 per CT-V900-A) Elevator Controller CA-A480-A (Max. 8 per CT-V900-A) Relay Expansion Module CA-A460-P (Max. 2 per CT-V900-A) 2-Door Expansion Module CA-A470-A (Max. 3 per CT-V900-A) E- BUS N ETWORK M ODULE C APACITY C ONTROLLER I NPUTS (U P TO 16 PER CONTROLLER ) + - Power Supply + - Power Supply Connect directly to controller lock terminals E LECTROMAGNETIC L OCK O PTION OR D OOR S TRIKE O PTION A LARM S OUNDER 2-D OOR C ONTROLLER CT-V900-A R1/DO GND R1/D1 12V OUT1 OUT2 OUT5 GREEN BLACK WHITE RED YELLOW (green LED) ORANGE (red LED) BROWN (buzzer) Blue (Clock) Not applicable with Centaur System R2/DO GND R2/D1 12V OUT3 OUT4 OUT6 DO - D1 + V (green LED) R (red LED) B (buzzer) H (Clock) Not applicable with Centaur System Connect earth terminal to cold water pipe Transformer 24 VAC, 75VA 50/60Hz Class 2 2 batteries (12V, 7AH) connected in series for 24V backup Reader wiring may differ from diagram. Please consult your dealer for details. S ERVER TO C ONTROLLER C OMMUNICATION Tamper Switch N.C. Contact To the controller serial port, up to 7.6M (25 ft) SERIAL PORT CABLE (DB9F to DB9F) RS-485 CONVERTER To the controller Network, up to 1220M (4000 ft) or To Server USB Port To Server Serial Port To Server Serial Port To Server Ethernet Port To remote modem and first controller of a site Telephone line connection To remote TCP/IP module (CA-ETHR-A) and first controller of a site To next controller of a site. MODULE NETWORK (E-BUS RS-485) Furthest module can be up to 1220M (4000ft) away from the CT-V900-A controller Polycarbonate Proximity Reader DGLP FN WLC Stainless Steel Proximity Reader DGLI WLC C ONTROLLER N ETWORK (RS-485) CT-V900-A 2-Door Controller POSITION GND TX B- +12V RX GND A+ GND RECEIVE TRANSMIT POWER CONVERTER SETTINGS EOL= ON Bias High/Low Jumpers A+= Low B-= Low CONTROLLER #2 SETTINGS EOL= OFF Bias High/Low Jumpers A+= High B-= High CONTROLLER #1 SETTINGS EOL= OFF Bias High/Low Jumpers A+= High B-= High CONTROLLER #3 SETTINGS EOL= ON Bias High/Low Jumpers A+= High B-= High START POINT of the RS-485 controller network. (Furthest modules can be up to 1220m (4000ft) from start point) END POINT of the RS-485 controller network CT-V900-A #1 CT-V900-A #2 CT-V900-A 2-Door Controller CT-V900-A #3 CT-V900-A 2-Door Controller ON OFF DEF/RUN 9.6K/19.2K ADD 32 ADD 16 ADD 8 ADD 4 ADD 2 ADD 1 1 2 3 4 5 6 7 8 ON OFF DEF/RUN 9.6K/19.2K ADD 32 ADD 16 ADD 8 ADD 4 ADD 2 ADD 1 1 2 3 4 5 6 7 8 ON OFF DEF/RUN 9.6K/19.2K ADD 32 ADD 16 ADD 8 ADD 4 ADD 2 ADD 1 1 2 3 4 5 6 7 8 RS-232 7.6m (25ft) max. Addressable dipswitch Addressable dipswitch Addressable dipswitch Example of Jumper Settings HIGH HIGH EOL EOL LOW LOW Jumper set to LOW Jumper set to HIGH Jumper set to EOL ON Jumper set to EOL OFF ON ON OFF OFF BATT BATT Jumper set to OFF Jumper set to ON CONTROLLER NETWORK JUMPERS ADDRESSABLE DIPSWITCH E-BUS NETWORK JUMPERS CT-V900-A CUT VIEW At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT. At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH Real-Time Clock Lithium Battery Setting SERVER C ONTROLLER N ETWORK J UMPER & D IPSWITCH S ETTINGS CA-A470-A 2-Door Expansion Module 4 5 1 2 3 CA-A470-A 2-Door Expansion Module 4 5 1 2 3 Elevator Controller CA - A480 - P Elevator Controller CA - A480 - P EOL= OFF Bias High/Low A+= High B-= High EOL= OFF Bias High/Low A+= High B-= High EOL= OFF Bias High/Low A+= High B-= High EOL= ON Bias High/Low A+= High B-= High EOL= ON Bias High/Low Jumpers A+= Low B-= Low START POINT of the RS-485 E-bus network (Furthest module can be up to 1220m (4000ft) from start point) END POINT of the RS-485 E-bus network CT-V900-A 2-Door Controller CT-V900-A CA-A480-A CA-A480-A CA-A470-A CA-A470-A ON OFF N/D PULSE 5&6 BACKUP2 BACKUP1 L2 Energize L1 Energize ADD 2 ADD 1 1 2 3 4 5 6 7 8 ON OFF N/D PULSE 5&6 BACKUP2 BACKUP1 L2 Energize L1 Energize ADD 2 ADD 1 1 2 3 4 5 6 7 8 ON OFF PWR OFF/ON DRM ENABLED RLY OFF/ON RLY COMMS ADDRESS 8 ADDRESS 4 ADDRESS 2 ADDRESS 1 1 2 3 4 5 6 7 8 ON OFF PWR OFF/ON DRM ENABLED RLY OFF/ON RLY COMMS ADDRESS 8 ADDRESS 4 ADDRESS 2 ADDRESS 1 1 2 3 4 5 6 7 8 At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH Addressable dipswitch Addressable dipswitch Addressable dipswitch Addressable dipswitch E- BUS N ETWORK J UMPER & D IPSWITCH S ETTINGS or LAN/WAN Network Fire alarm contact for Lock1 & Lock2 Destination Reporting Module CA-A482-P The DRM connects directly to the CA-A480-A, elevator controller TCP/IP Module CA-ETHR-A RS-485 Network Hub CA-A370-P S OFTWARE E DITIONS 1645-A Highway 440 West Laval, Quebec, Canada, H7L3W3 Tel.: (450) 682-7945, Toll Free Tel.: 1-866-610-0102 Fax: (450) 682-9590, Toll Free Fax: 1-866-682-9590

Upload: ml

Post on 06-Nov-2015

82 views

Category:

Documents


15 download

DESCRIPTION

control acces

TRANSCRIPT

  • w w w . c d v i . c a

    Input 11K Ohm

    Input 22.2K Ohm

    EOL1K Ohm

    Optional Loop Supervision

    +-

    +-

    +

    -

    +

    -

    +

    -

    +

    -

    !

    GN

    D

    A+

    B-

    GND

    A1+

    B1-

    +12V

    GND

    A2+

    B2-

    +

    -

    OptiOn 1:Local Connections

    OptiOn 2:Dial-up Connection

    OptiOn 3:tCp/ip Connection

    SyStem Overview

    Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules:pro-Report with tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontGuard: Display real-time visual authenticationFrontCard: Create, modify, delete and print cards, include Photo-IDLocator: Monitor real-time location of each card holderWaveplayer: Play a sound on any system event

    Workstation license(CS-WSLiC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console andall software modules.

    LitECS-AC-LitE

    StandardCS-AC-StD

    professionalCS-AC-pRO**

    EnterpriseCS-AC-Ent**

    Sites 1 64 64 64

    Serial Ports 1 1 1 4

    Dial Up - Yes Yes Yes

    TCP/IP - Yes Yes Yes

    Cards* 512 2,048 8,196 16,384

    Controllers* 16 32 64 256

    Doors* 16 128 512 2048

    * Per site ** Comes with a workstation license

    LCD DisplayCK-TRAK-L

    (Max. 8 per CT-V900-A)

    ElevatorController

    CA-A480-A(Max. 8 per CT-V900-A)

    RelayExpansion Module

    CA-A460-P(Max. 2 per CT-V900-A)

    2-DoorExpansion Module

    CA-A470-A(Max. 3 per CT-V900-A)

    e-buS NetwOrk mOdule CapaCity

    CONtrOller iNputS(up tO 16 per CONtrOller)

    +-Power

    Supply

    +-Power

    Supply

    Connect directly to controller lock terminals

    eleCtrOmagNetiC lOCk OptiON Or dOOr Strike OptiON

    alarm SOuNder

    2-dOOr CONtrOllerCt-v900-a

    R1/DO

    GND

    R1/D112VOUT1OUT2OUT5

    GREEN

    BLACK

    WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)

    Blue (Clock) Not applicable with Centaur System

    R2/DO

    GND

    R2/D112VOUT3OUT4OUT6

    DO

    -

    D1+V (green LED)R (red LED)B (buzzer)

    H (Clock) Not applicable with Centaur System

    Connect earth terminal to cold water pipe

    Transformer24 VAC, 75VA

    50/60Hz Class 2 2 batteries (12V, 7AH) connected in series for

    24V backup

    Reader wiring may differ from diagram. Please consult your dealer for details.

    Server tO CONtrOller COmmuNiCatiON

    Tamper Switch N.C. Contact

    To the controller serial port, up to

    7.6M (25 ft)

    SERiALpORt CAbLE(Db9F to Db9F)

    RS-485 COnVERtER

    To the controller Network, up to

    1220M (4000 ft)

    or

    To ServerUSB Port

    To ServerSerial Port

    To ServerSerial Port

    To ServerEthernet Port

    To remote modemand

    first controller of a site

    Telephone line connection

    To remote TCP/IP module(CA-ETHR-A) and

    first controller of a site

    To next controller of a site.

    mODuLE nEtWORk(E-buS RS-485)Furthest module can be up to 1220M (4000ft) away from the CT-V900-A controller

    polycarbonateproximityReaderDGLp Fn WLC

    Stainless Steelproximity Reader

    DGLi WLC

    CONtrOller NetwOrk(rS-485)

    CT-V900-A2-Door Controller

    P O S I T I O N

    GNDTXB-

    +12V

    RXG

    NDA+G

    ND

    RECEIVE

    TRANSMIT

    POWER

    CA-A360-A

    CONVERTERSETTINGS

    EOL= ON

    Bias High/Low JumpersA+= LowB-= Low

    CONTROLLER #2SETTINGS

    EOL= OFF

    Bias High/Low JumpersA+= HighB-= High

    CONTROLLER #1SETTINGS

    EOL= OFF

    Bias High/Low JumpersA+= HighB-= High

    CONTROLLER #3SETTINGS

    EOL= ON

    Bias High/Low JumpersA+= HighB-= High

    START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)

    END POINTof the RS-485 controller network

    CT-V900-A #1

    CT-V900-A #2

    CT-V900-A2-Door Controller

    CT-V900-A #3

    CT-V900-A2-Door Controller

    ONOFF

    DEF/R

    UN

    9.6K/19.2K

    ADD

    32

    ADD

    16

    ADD

    8

    ADD

    4

    ADD

    2

    ADD

    1

    1 2 3 4 5 6 7 8

    ONOFF

    DEF/R

    UN

    9.6K/19.2K

    ADD

    32

    ADD

    16

    ADD

    8

    ADD

    4

    ADD

    2

    ADD

    1

    1 2 3 4 5 6 7 8

    ONOFF

    DEF/R

    UN

    9.6K/19.2K

    ADD

    32

    ADD

    16

    ADD

    8

    ADD

    4

    ADD

    2

    ADD

    1

    1 2 3 4 5 6 7 8

    RS-2327.6m (25ft) max.

    Addressable dipswitch

    Addressable dipswitch

    Addressable dipswitch

    Example of Jumper Settings

    HIGH

    HIGH

    EOL

    EOL

    LOW

    LOW

    Jumper set to LOW

    Jumper set to HIGH

    Jumper set to EOL ON

    Jumper set to EOL OFF

    ON

    ON

    OFF

    OFF

    BATT

    BATTJumper set to OFF

    Jumper set to ON

    CONTROLLERNETWORK JUMPERS

    ADDRESSABLEDIPSWITCH

    E-BUSNETWORK JUMPERS

    CT-V900-A CUT VIEW

    At the START POINT and the END POINT of the RS-485 controller network, the controllers EOL jumpers= ON. All controllers in between EOL= OFF

    Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT.

    At the START POINT of the RS-485 controller network, the controllers HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

    Real-Time ClockLithium Battery Setting

    SERVER

    CONtrOller NetwOrkJumper & dipSwitCh SettiNgS

    +

    SP

    +12V

    R1/

    KP

    DR

    1/K

    PC

    R1/

    KP

    BR

    1/K

    PAO

    UT2

    OU

    T1R

    1/D

    1R

    1/D

    0R

    1/0V

    R1/

    +5V

    SP

    +12V

    R2/

    KP

    DR

    2/K

    PC

    R2/

    KP

    BR

    2/K

    PAO

    UT4

    OU

    T3R

    2/D

    1R

    2/D

    0R

    2/0V

    R2/

    +5V

    ACAC

    BAT+BAT-

    V+V+V-V-

    OUT5OUT6

    A+B-

    GNDTMPTMP

    D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

    CA-A470-A2-Door Expansion Module

    LOCK#1

    AC OK

    EOLBACKUP

    SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

    READER#1DATA

    READER#2DATA

    NO CARD

    LOW HIGH

    TX RXE-BUS

    B-A+

    2 CARDSALL CARDSUNLOCK DOOR

    20011

    10101

    AUX OKCOMMCHECK BATTBATT TRBL

    LOCK#2

    STATUS

    JP120350mA/700mA

    ON1 2

    3 4

    5 6

    7 8

    4

    5

    1

    2

    3

    +

    SP

    +12V

    R1/

    KP

    DR

    1/K

    PC

    R1/

    KP

    BR

    1/K

    PAO

    UT2

    OU

    T1R

    1/D

    1R

    1/D

    0R

    1/0V

    R1/

    +5V

    SP

    +12V

    R2/

    KP

    DR

    2/K

    PC

    R2/

    KP

    BR

    2/K

    PAO

    UT4

    OU

    T3R

    2/D

    1R

    2/D

    0R

    2/0V

    R2/

    +5V

    ACAC

    BAT+BAT-

    V+V+V-V-

    OUT5OUT6

    A+B-

    GNDTMPTMP

    D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

    CA-A470-A2-Door Expansion Module

    LOCK#1

    AC OK

    EOLBACKUP

    SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

    READER#1DATA

    READER#2DATA

    NO CARD

    LOW HIGH

    TX RXE-BUS

    B-A+

    2 CARDSALL CARDSUNLOCK DOOR

    20011

    10101

    AUX OKCOMMCHECK BATTBATT TRBL

    LOCK#2

    STATUS

    JP120350mA/700mA

    ON1 2

    3 4

    5 6

    7 8

    4

    5

    1

    2

    3

    STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

    ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

    12

    34

    56

    78

    ON

    NO14

    NO13

    NC14

    NC13

    COM16NC15NO15

    NO16NC16

    COM15

    COM14

    COM13

    NO3

    NO4

    NC2

    NC3

    COM1

    NC1

    NO2

    NO1

    COM2

    COM3

    COM4

    NC4

    NO

    7

    NO

    8

    NC

    6

    NC

    7

    COM

    5

    NC

    5

    NO

    6

    NO

    5

    COM

    6

    COM

    7

    COM

    8

    NC

    8

    NO

    11

    NO

    12

    NC

    10

    NC

    11

    COM

    9

    NC

    9

    NO

    10

    NO

    9

    COM

    10

    COM

    11

    COM

    12

    NC

    12

    A+

    GNDB-

    TAMPERTAMPER

    FC

    +12V

    AC

    BAT+BAT-

    AC

    +12VGNDGND

    FC

    RL16RL1

    RL2RL3

    RL4

    RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

    RL13

    RL14

    RL15

    DRM

    MO

    DULE

    BATT REVERSED12V

    +12V RELAYBATT

    AC

    EOL

    BLOW HIGH

    ALOW HIGH

    FC OVERIDE350mA/700mA

    E-BUSTXRX

    Elevator ControllerCA - A480 - P

    E-BUS

    STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

    ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

    12

    34

    56

    78

    ON

    NO14

    NO13

    NC14

    NC13

    COM16NC15NO15

    NO16NC16

    COM15

    COM14

    COM13

    NO3

    NO4

    NC2

    NC3

    COM1

    NC1

    NO2

    NO1

    COM2

    COM3

    COM4

    NC4

    NO

    7

    NO

    8

    NC

    6

    NC

    7

    COM

    5

    NC

    5

    NO

    6

    NO

    5

    COM

    6

    COM

    7

    COM

    8

    NC

    8

    NO

    11

    NO

    12

    NC

    10

    NC

    11

    COM

    9

    NC

    9

    NO

    10

    NO

    9

    COM

    10

    COM

    11

    COM

    12

    NC

    12

    A+

    GNDB-

    TAMPERTAMPER

    FC

    +12V

    AC

    BAT+BAT-

    AC

    +12VGNDGND

    FC

    RL16RL1

    RL2RL3

    RL4

    RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

    RL13

    RL14

    RL15

    DRM

    MO

    DULE

    BATT REVERSED12V

    +12V RELAYBATT

    AC

    EOL

    BLOW HIGH

    ALOW HIGH

    FC OVERIDE350mA/700mA

    E-BUSTXRX

    Elevator ControllerCA - A480 - P

    E-BUS

    EOL= OFF

    Bias High/LowA+= HighB-= High

    EOL= OFF

    Bias High/LowA+= HighB-= High

    EOL= OFF

    Bias High/LowA+= HighB-= High

    EOL= ON

    Bias High/LowA+= HighB-= High

    EOL= ON

    Bias High/Low JumpersA+= LowB-= Low

    START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)

    END POINTof the RS-485 E-bus network

    CT-V900-A2-Door Controller

    CT-V900-A

    CA-A480-A CA-A480-A

    CA-A470-A CA-A470-A

    ONOFF

    N/D

    PULSE 5&6

    BACKU

    P2

    BACKU

    P1

    L2 Energize

    L1 Energize

    ADD

    2

    ADD

    1

    1 2 3 4 5 6 7 8ONOFF

    N/D

    PULSE 5&6

    BACKU

    P2

    BACKU

    P1

    L2 Energize

    L1 Energize

    ADD

    2

    ADD

    1

    1 2 3 4 5 6 7 8

    ONOFF

    PWR

    OFF/O

    N

    DR

    M EN

    ABLED

    RLY O

    FF/ON

    RLY C

    OM

    MS

    ADD

    RESS 8

    ADD

    RESS 4

    ADD

    RESS 2

    ADD

    RESS 1

    1 2 3 4 5 6 7 8

    ONOFF

    PWR

    OFF/O

    N

    DR

    M EN

    ABLED

    RLY O

    FF/ON

    RLY C

    OM

    MS

    ADD

    RESS 8

    ADD

    RESS 4

    ADD

    RESS 2

    ADD

    RESS 1

    1 2 3 4 5 6 7 8

    At the START POINT and the END POINT of the installation, the modules EOL jumpers = ON. All modules in between EOL = OFF

    At the START POINT of the network, the modules HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

    Addressabledipswitch

    Addressabledipswitch

    Addressabledipswitch

    Addressabledipswitch

    e-buS NetwOrkJumper & dipSwitCh SettiNgS

    or

    LAN/WAN Network

    Fire alarm contact for Lock1 & Lock2

    DestinationReporting Module

    CA-A482-PThe DRM connects directly

    to the CA-A480-A,elevator controller

    TCP/IPModule

    CA-ETHR-A

    RS-485Network HubCA-A370-P

    SOftware editiONS

    1645-A Highway 440 WestLaval, Quebec, Canada, H7L3W3

    Tel.: (450) 682-7945, Toll Free Tel.: 1-866-610-0102Fax: (450) 682-9590, Toll Free Fax: 1-866-682-9590