cdf 40 dehumidifier function - dantherm · ds/en 22768-1 medium. ... the cdf 50 is an energy...
TRANSCRIPT
FunctionThe CDF 40 is an energy efficient and quiet dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidi-fier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is ap-prox. 5°C higher than at the inlet.
Applications• Archives• Museums• Churches• Changing rooms • Waterworks
CDF 40 DEHUMIDIFIER
FIXED DEHUMIDIFIERS CDF
FEATURES
Dehumidifier• Built into a strong and robust powder coated hot galvanized sheet metal
cabinet• Evaporator and condenser coils are epoxy-coated for high corrosion
resistance• Fixed to the wall by means of a wall mounting strip supplied with the unit• Condensate outlet located at the bottom. Outlet stub can be connected
to a ¾” hose• Outside connection to mains
Control• Built in electronic hygrostat and thermostat• Integrated ON/OFF control of humidity and temperature (electric or water
heating coils as accessories)• 0-VOLT connection for alarm• 230 V for control valve, exhaust fan and pump/boiler• RS 485 gate for BMS (Modbus)
DiodesBLUE: Power connected, standby modeGREEN: Compressor ON, deicingYELLOW: Remote pairing modeRED: Errors
DefrostingActive, demand-controlled defrosting is incorporated in the electronic control.
ServiceFor easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.
40% 60% 80%3 0,08 0,13 0,16 gæt
10 0,19 0,32 0,4715 0,23 0,5 1,0220 0,3 0,68 1,3530 0,55 1,25 1,92 gæt32 0,67 1,45 2,14
CDF 40
0
5
10
15
20
25
30
35
0 0,5 1 1,5 2 2,5
Temp.
L/H
capacity curve for CDF 40 40%
60%
80%
Model CDF 40Operating range – humidity 40 – 100 %RHOperating range – temperature 3 – 32°CAir volume 400 m3/hPower supply 1x230 V/50 HzMax. ampere consumption 3,4 AMax. power consumption 0,78 kWRefrigerant R407CQuantity of refrigerant 0,7 kgCompressor RotaryFan RadialSound level (at 1 metre) 46 dB(A)Weight 56,5 kgFilter G3 PPI 15Colour (Cabinet/Front) RAL 9005/9006Protection class IPX4Corrosion protection in accordance with EN/ISO 12944-2 C4
dantherm.com
TECHNICAL DATA
FIXED DEHUMIDIFIERS CDF
CAPACITY CURVES
INSTALLATION
Specific energy consumption (SEC): 0,80 kWh/l at 20°C & 60% RH
CDF 40°C
l/h
40% RH 60% RH 80% RH
FIXED DEHUMIDIFIERS CDF
DIMENSIONS CDF 40
AccessoriesWireless remote control DRC1Floor mounting kit Water heating coils Control valve for water heating coilsElectric heating coils Exhaust fans
dantherm.com
Drain outlet position
Recommended installation of CDF 40
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
Min
. 225
M
in. 2
25
727
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S process equipment and is only entended as a guide.
CDP Large
CDP Large
8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
Surface appearance according to referencetable LZT 142 0001, category
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
DETAIL ASCALE 1 : 2
A
Min
. 225
Min
. 225
727
430,2
56,4
1010
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
process equipment and is only intended as a guide.
SCALE: NOT TO SCALE
351 514
bof
988453.42g
19-08-2017
"Thickness@@part1.SLDPRT"mm
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
table LZT 142 0001, category
CDF 50
CDF 50
Surface appearance according to reference8
Sheetmetal flatstate is based on Dantherm Air Handling A/S
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
913
950
,5
327,8
1010
430,2
59,1
326,1
913
950,
5
Floor mounting kit
All dimensions are in mm.
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
769,
2
315,6
699,
9
326,1
CDF 50 DEHUMIDIFIER
FIXED DEHUMIDIFIERS CDF
FunctionThe CDF 50 is an energy efficient and quiet dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidi-fier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is ap-prox. 5°C higher than at the inlet.
Applications• Archives• Museums• Churches• Changing rooms • Waterworks
FEATURES
Dehumidifier• Built into a strong and robust powder coated hot galvanized sheet metal
cabinet• Evaporator and condenser coils are epoxy-coated for high corrosion
resistance• Fixed to the wall by means of a wall mounting strip supplied with the unit• Condensate outlet located at the bottom. Outlet stub can be connected
to a ¾” hose• Outside connection to mains
Control• Built in electronic hygrostat and thermostat• Integrated ON/OFF control of humidity and temperature (electric or water
heating coils as accessories)• 0-VOLT connection for alarm• 230 V for control valve, exhaust fan and pump/boiler• RS 485 gate for BMS (Modbus)
DiodesBLUE: Power connected, standby modeGREEN: Compressor ON, deicingYELLOW: Remote pairing modeRED: Errors
DefrostingActive, demand-controlled defrosting is incorporated in the electronic control.
ServiceFor easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.
40% 60% 80%3 0,03 0,19 0,45 gæt
10 0,22 0,54 0,8815 0,34 0,78 1,5220 0,45 1,45 2,3730 0,77 2,2 3,3 gæt32 0,88 2,49 3,67
CDF 50
0
5
10
15
20
25
30
35
0 0,5 1 1,5 2 2,5 3 3,5 4
Temp.
L/H
capacity curve for CDF 50 40%
60%
80%
Model CDF 50Operating range – humidity 40 – 100 %RHOperating range – temperature 3 – 32°CAir volume 680 m3/hPower supply 1x230 V/50 HzMax. ampere consumption 4,7 AMax. power consumption 1,08 kWRefrigerant R407CQuantity of refrigerant 0,9 kgCompressor RotaryFan RadialSound level (at 1 metre) 47 dB(A)Weight 65 kgFilter G3 PPI 15Colour (Cabinet/Front) RAL 9005/9006Protection class IPX4Corrosion protection in accordance with EN/ISO 12944-2 C4
dantherm.com
TECHNICAL DATA
FIXED DEHUMIDIFIERS CDF
CAPACITY CURVES
INSTALLATION
Specific energy consumption (SEC): 0,63 kWh/l at 20°C & 60% RH
CDF 50°C
l/h
40% RH 60% RH 80% RH
process equipment and is only intended as a guide.
SCALE: NOT TO SCALE
351 514
bof
988453.42g
19-08-2017
"Thickness@@part1.SLDPRT"mm
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
table LZT 142 0001, category
CDF 50
CDF 50
Surface appearance according to reference8
Sheetmetal flatstate is based on Dantherm Air Handling A/S
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
913
950
,5
327,8
FIXED DEHUMIDIFIERS CDF
DIMENSIONS CDF 50
AccessoriesWireless remote control DRC1Floor mounting kit Water heating coils Control valve for water heating coilsElectric heating coils Exhaust fans
dantherm.com
All dimensions are in mm.
Floor mounting kit
Drain outlet position
Recommended installation of CDF 50
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
Min
. 225
M
in. 2
25
727
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S process equipment and is only entended as a guide.
CDP Large
CDP Large
8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
Surface appearance according to referencetable LZT 142 0001, category
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
DETAIL ASCALE 1 : 2
A
Min
. 225
Min
. 225
727
430,2
56,4
1010
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
1160
430,2
59,1
326,1
913
950,
5
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
769,
2
315,6
699,
9
326,1
CDF 70 DEHUMIDIFIER
FIXED DEHUMIDIFIERS CDF
FunctionThe CDF 70 is an energy efficient and quiet dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidi-fier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is ap-prox. 5°C higher than at the inlet.
Applications• Archives• Museums• Churches• Changing rooms • Waterworks
FEATURES
Dehumidifier• Built into a strong and robust powder coated hot galvanized sheet metal
cabinet• Evaporator and condenser coils are epoxy-coated for high corrosion
resistance• Fixed to the wall by means of a wall mounting strip supplied with the unit• Condensate outlet located at the bottom. Outlet stub can be connected
to a ¾” hose• Outside connection to mains
Control• Built in electronic hygrostat and thermostat• Integrated ON/OFF control of humidity and temperature (electric or water
heating coils as accessories)• 0-VOLT connection for alarm• 230 V for control valve, exhaust fan and pump/boiler• RS 485 gate for BMS (Modbus)
DiodesBLUE: Power connected, standby modeGREEN: Compressor ON, deicingYELLOW: Remote pairing modeRED: Errors
DefrostingActive, demand-controlled defrosting is incorporated in the electronic control.
ServiceFor easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.
40% 60% 80%3 0,03 0,19 0,4 gæt
10 0,3 0,6 0,915 0,4 0,96 2,0220 0,64 1,77 2,9830 1,3 2,3 4,2 gæt32 1,44 2,46 4,5
CDF 70
0
5
10
15
20
25
30
35
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Temp.
L/H
capacity curve for CDF 70 40%
60%
80%
Model CDF 70Operating range – humidity 40 – 100 %RHOperating range – temperature 3 – 32°CAir volume 900 m3/hPower supply 1x230 V/50 HzMax. ampere consumption 6,5 AMax. power consumption 1,5 kWRefrigerant R407CQuantity of refrigerant 1,2 kgCompressor RotaryFan RadialSound level (at 1 metre) 50 dB(A)Weight 75,5 kgFilter G3 PPI 15Colour (Cabinet/Front) RAL 9005/9006Protection class IPX4Corrosion protection in accordance with EN/ISO 12944-2 C4
dantherm.com
TECHNICAL DATA
FIXED DEHUMIDIFIERS CDF
CAPACITY CURVES
INSTALLATION
Specific energy consumption (SEC): 0,58 kWh/l at 20°C & 60% RH
CDF 70°C
l/h
40% RH 60% RH 80% RH
process equipment and is only intended as a guide.
SCALE: NOT TO SCALE
351 514
bof
988453.42g
19-08-2017
"Thickness@@part1.SLDPRT"mm
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
table LZT 142 0001, category
CDF 50
CDF 50
Surface appearance according to reference8
Sheetmetal flatstate is based on Dantherm Air Handling A/S
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
913
950
,5
327,8
FIXED DEHUMIDIFIERS CDF
DIMENSIONS CDF 70
AccessoriesWireless remote control DRC1Floor mounting kit Water heating coils Control valve for water heating coilsElectric heating coils Exhaust fans
dantherm.com
All dimensions are in mm.
Floor mounting kit
Drain outlet position
Recommended installation of CDF 70
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
Min
. 225
M
in. 2
25
727
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S process equipment and is only entended as a guide.
CDP Large
CDP Large
8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
Surface appearance according to referencetable LZT 142 0001, category
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
DETAIL ASCALE 1 : 2
A
Min
. 225
Min
. 225
727
430,2
56,4
1010
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
988453.42g
Surface appearance according to reference
SCALE: NOT TO SCALE
process equipment and is only intended as a guide.
"Thickness@@part1.SLDPRT"mm
CDF 50 19-08-2017
351 514
351514
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
REF.:
DATE:
PART NO REV.:
REV.:
All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents.
bof
table LZT 142 0001, category
CDF 50
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S 8
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
314,5
699
,9
327,8
CDF40 1010
CDF50 1160
CDF 70 1495
430,2
59,
1
1495
430,2
59,1
326,1
913
950,
5
table LZT 142 0001, category process equipment and is only entended as a guide.
CDP Large
CDP Large
8
property of said Company and will be protected by Patents.
Surface appearance according to reference
g
SCALE: NOT TO SCALE
351 512
351512
MATERIAL:
THICKNESS: WEIGHT:
REV. BY:
DATE:
PART NO REV.:
REV.:
PAR
TN
O
Sheetmetal flatstate is based on Dantherm Air Handling A/S
REF.:
DATE:All designs originated by Dantherm Air Handling A/S are the
This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S.
Linear dimensions without tolerances according to DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1°
CDP 50 - 1160
CDP 40 - 1010
CDP 70 - 1495
56,
4 430,2
315,6
769
,2
699
,9
326,1
769,
2
315,6
699,
9
326,1
FIXED DEHUMIDIFIERS CDF
ACCESSORIES CDP 35 – CDP 45 – CDP 65 – CDP 35T – CDP 45T – CDP 65T
dantherm.com
Illustration Accessory Description CDF-type Dantherm No.
ACCESSORIES CDF 10 – CDF 40 – CDF 50 – CDF 70
DRC1 is a wireless RH and temperature controller Frequency: 433 mhz Range up to 50 m depending on the conditions Protection class: IP 20 Functionalities: • Reading and setting of RH
and temperature, alarmsand service information
• Locking of settings
White or grey CDF 10 351615Watertank
Each bracket to be mounted on each side of the dehumi-difier
Comprises valve and actuator 230 V, ON/OFF (180 seconds from closed to fully open), incl. union nut for Ø 12 cu tube
Comprises water heating coil, flexible hose, fittings and gasket
*at 80/60° C
(See technical specifications for water heating coils on separate page)
Remote control, DRC1
Floor mounting kit, 2 pcs.- black
DN 10 control valve and actuator for water heating coils
Water heating coil 3,2 kW*)
Water heating coil 5,1 kW*)
Water heating coil 7,4 kW*)
CDF 40
CDF 70
CDF 50
094333
094334
094335
CDF 40 CDF 50 CDF 70
CDF 40 CDF 50 CDF 70
093455
094340
CDF 40 CDF 50 CDF 70
094332
FIXED DEHUMIDIFIERS CDF
ACCESSORIES CDP 35 – CDP 45 – CDP 65 – CDP 35T – CDP 45T – CDP 65T
dantherm.com
Illustration Accessory Description CDF-type Dantherm No.
The exhaust fan can be used in combination with the CDF to either increase dehumidi-fication capacity or establish outdoor air supply.
Relay and electric wire are included.
Exhaust fan, Q = 97 m3/h
Exhaust fan, Q = 185 m3/h
CDF 40 CDF 50 CDF 70
CDF 40 CDF 50 CDF 70
094339
094341
Comprises electric heating coil, relays and electric wires
Electric heating coil 2 kW
Electric heating coil 3,5 kW
Electric heating coil 5 kW
094336
094337
094338
CDF 40
CDF 70
CDF 50
ACCESSORIES CDF 10 – CDF 40 – CDF 50 – CDF 70
Water heating coils - calculations at room temperature = 20°C; 50% RH
dantherm.com
CDF 40 Q=400 m3/hWater temperature °C 82/71 80/60 70/35 90/70 60/40 55/45 Capacity kW 3,85 3,19 1,16 3,94 1,64 1,91 Water flow rate l/sec. 0,09 0,04 0,01 0,05 0,02 0,05 Water pressure drop kPa 15,5 3,9 0,3 5,5 1,3 5,7 Water velocity m/sec. 1,22 0,56 0,11 0,69 0,28 0,66 Air flow rate m3/sec. 0,11 0,11 0,11 0,11 0,11 0,11 Inlet temperature °C 82 80 70 90 60 55 Outlet temperature °C 71 60 35 70 40 45 Air pressure drop Pa 8 8 8 8 8 8 Connection tube mm 12 12 12 12 12 12
CDF 50 Q=680 m3/hWater temperature °C 82/71 80/60 70/35 90/70 60/40 55/45 Capacity kW 6,11 5,12 2,42 6,29 2,75 3,08 Water flow rate l/sec. 0,14 0,06 0,02 0,08 0,03 0,08 Water pressure drop kPa 42,2 10,6 1,1 14,9 3,8 15,6 Water velocity m/sec. 1,94 0,06 0,24 1,1 0,48 1,07 Air flow rate m3/sec. 0,19 0,19 0,19 0,19 0,19 0,19 Inlet temperature °C 82 80 70 90 60 55 Outlet temperature °C 71 60 35 70 40 45 Air pressure drop Pa 10 10 10 10 10 10 Connection tube mm 12 12 12 12 12 12
CDF 70 Q=900 m3/hWater temperature °C 82/71 80/60 70/35 90/70 60/40 55/45 Capacity kW 8,74 7,43 3,86 9,07 4,12 4,47 Water flow rate l/sec. 0,19 0,09 0,03 0,11 0,05 0,11 Water pressure drop kPa 108,1 27,7 3,4 38,7 10,3 40,7 Water velocity m/sec. 2,78 1,3 0,38 1,59 0,71 1,55 Air flow rate m3/sec. 0,25 0,25 0,25 0,25 0,25 0,25 Inlet temperature °C 82 80 70 90 60 55 Outlet temperature °C 71 60 35 70 40 45 Air pressure drop Pa 8 8 8 8 8 8 Connection tube mm 12 12 12 12 12 12
ACCESSORIES CDF 40 - CDF 50 - CDF 70
FIXED DEHUMIDIFIERS CDF