      Caldera was first established in 2004 as a distributor of towel radiators across Europe. Then, the company became

    Caldera Heating Group with the addition of steel boiler production. Today, the company has expanded its organization

    with the production of cast iron boilers, wood gasification boilers, and biomass (pellet) boilers, and the distribution of

    other products such as gas fired water heaters, hot water cylinders, and design radiators.

    Recently, Caldera Heating Group established its own sales, distribution, and after-sales service network in Turkey with

    new products typical of this market such as automatic feeding boilers for small size coals and gas fired water heaters.

    Caldera Heating Group exports its products to more than 23 countries around the world (especially to Europe), and

    we're working to expand exports to different countries.

    We use the latest technology in all of our products which are our own registered and approved designs. We strive to

    develop the highest quality, environmentally friendly products.

    Each welder in Caldera Heating Group is approved on EN ISO 287-1 as well as our own welding process. We use a

    synergistic system that include MAG and TIG welding machines and the most advanced system for welding gas exhaust.

    We also have our own combustion and research laboratory with and advanced data acquisition system.

    All of our products are CE approved, and manufactured to meet or exceed European Community Directives and

    relevant harmonized standards for each category.

    Our goal is to provide the highest customer satisfaction by manufacturing and distributing the highest quality products

    and providing the best service, and we plan to grow and prosper in this sector over the long term.

    CALDERA HEATING GROUP

    Our products today include:

    - Steel boilers for solid f uels (natural draught and fan assisted models)

    - Wood gasification boilers with pyrolytic combustion

    - Cast iron boilers for solid fuels

    - Biomass (pellet) boilers

    - Cast Iron Radiators ( Victoria )

    - Towel radiators

    - Design radiators (stainless steel and aluminum)

    - Gas fired water heaters

    - Floor standing hot water cylinders

    - Hot water cylinders with integrated wall-hanging electric heaters

  • 8/9/2019 Caldera Kotlovi

    3/29

    steel boilers

    for solid fuels

  • 8/9/2019 Caldera Kotlovi

    4/29

    L

    L1

    ØD

    W

       H   H   4

       H   1

       H   2

       H   3

    R  ½ ” 

     D

     R  1 ½ ”

      G

    D  D

    Caltherm SHigh Efficiency Steel Boilers (Natural Draught)

    Up to 70 kW

    Manual loading

    Three pass flue circulation

       T   e   c   h   n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

    Compact and high efficiency solutions for manually loaded boilers

    Suitable for firing wood logs, brown coal, and lignite

    High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

    Natural draught combustion controlled by primary air regulation via thermostatic controller

    Manual adjustment on secondary air for better combustion and flue emissions

    Easy loading and boiler cleaning due to properly sized front doors

    Cast iron bottom grade for long operation life

    Scaled thermometer to monitor boiler outlet temperature

    Optional cooling loop for protection against over-heating

    Reliable materials, approved production quality and good finishing

    CE approval on Pressure Equipment Directive (97/23/EC)

    CT 17 S CT 25 S CT 35 S CT 45 S CT 55 S CT 70 S

    kW 17 25 35 45 55 70

    kcal/h 14.600 22.000 30.000 40.000 48.000 60.000

    Models Caltherm S

    Types

    Output

    Water Content lt 58 66 75 85 105 120

      Height mm

    Width mm

    Depth mm 381 765

    F ue l lo ad in g cl earanc e (u pp er d oo r) m mxmm

    Max. Fu el lo ad in g h ei gh t ( fo r l og wo od ) m m

    Temperature control range   ºC

    Maximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) RSafety heat exchanger connection R

    Filling / draining connection R

    E xt ernal d im en si on s Hei gh t ( H) m m

    H1 mm

    H2 mm

    H3 mm

    H4 mm

    Width (W) mm

    Length (L) mm 490 870

    L1 mm 630 1010

    F lu e o ut le t d ia me te r ( D) m m

    1125

    2,5

    30-90

    420 x 215330 × 215

    400

    480 X 265

    160 180

    100

    50 (recommended)

    770

    630

    870

    730

    621

    1180

    1 ¾"1 "1½"

    ½"

    490

    330 420 480

    525

    230

    215

    11001000

    1090

    490 640580

    1215

    Combustionchamber

    dimensions

  • 8/9/2019 Caldera Kotlovi

    5/29

    Caltherm BasicMedium Efficiency Steel Boilers (Natural Draught)

    Up to 45 kW

    Manual loading

    Two pass flue circulation

    Compact solutions for manually loaded boilers, ideal for DIY and wholesaler channels

    Suitable for firing wood logs, brown coal, and lignite

    High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

    Natural draught combustion controlled by primary air regulation via thermostatic controller

    Easy loading and boiler cleaning due to properly sized front doors

    Cast iron bottom grade for long operation life

    Scaled thermometer to monitor boiler outlet temperature

    Optional cooling loop for protection against over-heating

    Reliable materials, approved production quality and good finishing

    CE approval on Pressure Equipment Directive (97/23/EC)

       T   e   c   h

       n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Water Content lt 68 75 85 95

      Height mm

    Width mm

    Depth mm 370 430 525 620

    F ue l l oa di ng cl ea ra nc e ( up pe r d oo r) m mx mm

    M ax . F ue l l oa di ng he ig ht (fo r l og woo d) mm

    Temperature control range   ºC

    Maximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R

    Safety heat exchanger connection R

    Filling / draining connection R

    E xt er na l d im en si on s H ei gh t ( H) m m

    H1 mm

    H2 mm

    H3 mm

    H4 mm

    Width (W) mm

    Length (L) mm 460 523 623 718

    L1 mm 610 588 688 783

    F lu e o utl et di ame te r ( D) mm

    100

    2"

    1 ½"

    ½"

    160

    480

    190

    1073

    50 (recommended)

    2,5

    375

    375 x 280

    400

    30 to 90

    320

    530

    1093

    985

    Combustionchamber

    dimensions

    CT 23 B CT 28 B CT 35 B CT 45 B

    kW 23 28 35 45

    kcal/h 20.000 24.000 30.000 40.000

    Models

    Types

    Output

    Caltherm Basic

    L

    L1

       H   H   4

    D

    W

       H   3

       H   1

       H   2

      D

    D  G

    R ½”

    R 1½”

      D

  • 8/9/2019 Caldera Kotlovi

    6/29

    Caltherm FHigh Efficiency Steel Boilers (Fan Assisted Combustion)

    Up to 70 kW

    Manual loading

    Fan speed modulation

     Electronic control

     Sophisticated energy saving

    and safety features

    High efficiency solutions for manually loaded boilers

    Suitable for firing wood logs, brown coal, and lignite

    Optional cooling loop for protection against over-heating

    Reliable materials, approved production quality and good finishing

    CE approval on Pressure Equipment Directive (97/23/EC)

    Energy saving and safety features due to programmed PCB

    Easy loading and boiler cleaning due to properly sized front doors

    Stylish electronic control board with well organized function buttons and big LCD screen

    High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

    Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

    Room thermostat option

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Night and ECO modes to save energy

    Adjustable flue damper on smokehood

    Cast iron bottom grade for long operation life

       T   e   c   h

       n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Water Content lt 72 80 124

      Height mm

    Width mm 330 420 480

    Depth mm 525 525 765

    F ue l loading c le aran ce (u pp er do or ) m mxmm 330×215

    Max. Fuel loading height (for log wood) mm 500

    Temperature control range   ºC

    Maximum operatingtemperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R 1 " 1 " 1¾"

    Connec. for safety inlet/outlet (dg,dd) R

    Safety heat exchanger connection R

    Filling / draining connection R

    E xt erna ld im en sion s H eigh t ( H) m m

    H1 mm

    H2 mm

    H3 mm

    H4 mm

    Width (W) mm 490

    W1 mm

    Length (L1) mm 1350

    L2 mm 880

    L3 mm

    Flue outlet diameter (D) mm 160

    Electrical supply V/Hz

    Power consumption W

    840 930

    400

    740

    12101110

    640

    180

    480X 365

    475

    1090 1180

    8882

    180

    420x 215

    580 640

    450

    CT 25 F CT 35 F CT 70 F

    kW 25 35 70

    kcal/h 22.000 30.000

    108

    480

    621

    450

    1¾"

    CT 55 F

    55

    48.000 60.000

    90

    420

    621

    1 "

    260

    245

    375

    2,5

    40 (recommended)

    100

    ½"

    230/50

    50 to 90

    1½"

    1 "

    CT 45 F

    45

    40.000

    Caltherm F

    Output

    Types

    Models

    Combustionchamber

    dimensions

    ØD

    L3

    L2

    L1

    D  G

    d  g

    d  d

    D  D

    W

       H

       1   0   2

    W1

       H   1

       H   2   H

       3

    R ¾”

  • 8/9/2019 Caldera Kotlovi

    7/29

    High Efficiency Steel Boilers for Central Heating systems(Fan Assisted Combustion)

    Up to 290 kW

    Manual loading

     Electronic control with fan speed modulation

     Sophisticated energy saving and safety features

    Auto ash-discharge mechanism

    Caltherm XF

    High efficiency solutions for manually loaded boilers

    Suitable for firing wood logs, brown coal, and lignite

    Cast iron bottom grade for long operation life

    CE approval on Pressure Equipment Directive (97/23/EC)

    Energy saving and safety features due to programmed PCB

    Reliable materials, approved production quality and good finishing

    Stylish electronic control board with well organized function buttons and big LCD screen

    Manually activated auto ash-discharge mechanism with movable cast iron bottom grates (only for 90 and 115 kw)

    High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

    Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

    Easy loading and boiler cleaning due to properly sized and separated front loading and cleaning doors

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Night and ECO modes to save energy

    Room thermostat option

    Adjustable flue damper on smokehood

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

       T   e   c   h

       n   i   c   a   l   D   a   t   a

    Water Content lt 221 258 325 400 420 474 546

      Height mm

    Width mm

    Depth mm 710 830 920 1140 1330

    Fuel loading c learance (upper door) mmxmm

    Max . Fu el l oa di ng h ei gh t (f or l og w oo d) m m

    Temperature control range   ºC

    Maximum operatingtemperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R 3"

    Connec. for safety inlet/outlet (d g,dd) R

    Filling / draining connection R

    External dimensions Height (H) mm 1400 1400 1625 1625 1715 1815 1815

    H1 mm

    H2 mm

    H3 mm

    Width (W) mm

    W1 mm

    Length (L1) mm 1420 1530 1640 1860 1420 1530 1640

    L2 mm 860 980 1060 1280 860 980 1060

    L3 mm 1100 1220 1350 1454 1100 1220 1350

    F lu e o ut le t d ia me te r ( D) m m

    Electrical supply V/Hz

    Power consumption W

    770

    200 260220

    940

    335

    3,2

    50 to 90

    100

    40 (recommended)

    1130

    690x280

    580550 600

    550

    550 x 285 550 x 320

    760

    580

    CTX 80 F CTX 100 F CTX 125 F CTX 150 F CTX 175 F CTX 200 F CTX 250 F

    kW 90 115 145 175 200 230 290

    kcal/h 80.000 100.000 125.000 150.000 175.000 200.000 250.000

    Caltherm XFModels

    Types

    Output

    550 600

    310

    ¾"

    485

    1 ¼"

    1½" 2" 2½"

    825

    230/50

    230

    Combustionchamber

    dimensions

    L2

    L3

    L1

    dg

    dd

    DG

    DD

       H   1

       H   2   H

       3

    R3/4"

       H   4

    W

       H

    ØD

  • 8/9/2019 Caldera Kotlovi

    8/29

     W

       1   0   1

     W1

    D

    L

    L1

       H 

    d d

    D D

    R

    D G

    d g

        H   1

        H   2

       H   3

    High Efficiency Steel Boilers(Fan Assisted Combustion)

    Up to 70 kWManual loading

    Fan speed modulation

     Electronic control

     Ideal for small size coals,

    and coal+dust mixtures

    by particular secondary

    air distribution

    Caltherm KF

    High efficiency solutions for manually loaded boilers

    Particular secondary air distribution on top of combustion chamber

    Energy saving and safety features due to programmed PCB

    Particular front doors for loading and cleaning.

    Energy saving and safety features due to programmed PCB

    Movable cast iron bottom grade for long operation life

    Manually activated auto ash discharge mechanism

    Stylish electronic control board with well organized function buttons and big LCD screen

    Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

    Suitable for firing wood logs, standard and smal size (< 20 mm) brown coal and lignite, small size coal with dust inside

    High heating surface and smoke tube design with integrated fume retarders on third passage result in high efficiencyLong combustion periods due to increased combustion chamber volume (up to 2 days with one full loading when fired with small size coals)

    Room thermostat option

    Full three-pass circulation

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Night and ECO modes to save energy

    Adjustable flue damper on smokehood

       T   e   c   h   n

       i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

    Water Content lt 85 95 114 136

      Height mm

    Width mm

    Depth mm 525 621 621 765

    Fu el l oa di ng c lea ra nc e ( up per d oo r) m mx mm

    M ax . F ue l l oa di ng he ig ht (f or lo g w oo d) m m

    Temperature control range   ºC

    Maximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R

    Connec. for safety inlet/outlet (d g,dd) R

    Filling / draining connection R

    E xter na l d im en si on s H ei gh t ( H) m m

    H1 mm

    H2 mm

    H3 mm

    Width (W) mm

    W1 mm

    Length (L1) mm 940 1180

    L2 mm 800 1040

    L3 mm 640 880

    F lu e o ut le t d ia me te r ( D) mm

    Electrical supply V/Hz

    Power consumption W 200

    500 600

    50 to 90

    100

    40 (recommended)

    2,5

    420 480

    420 x 260 480 x 300

    550 600

    1340

    650590

    960900

    1 "

    1 "

    480

    270

    145

    180

    230/50

    1040

    1 ¼"

    1455

    ½"

    900

    740

    160

    85

    CT 30 KF CT 40 KF CT 48 KF CT 60 KF

    kW 35 45 55 70

    kcal/h 30.000 40.000 48.000 60.000

    Models

    Types

    Output

    Caltherm KF

    Combustionchamber

    dimensions

  • 8/9/2019 Caldera Kotlovi

    9/29

    Caltherm SFAutomatic Feeding Boilers For Walnut-Coals And Pirina(Fan Assisted Combustion) 

    Up to 115 kWElectronic control with fan speed modulation

     Sophisticated energy saving and safety features

     L3

    L2

    L1

    D

    dd

    DD

    DG dg

     W1 W

        H 

       1   0       1

            H       2       H

           1

            H       3

    ddol.

    boþ.

    Adjustable flue damper on smokehood

    Easy operation and cleaning, high comfort

    Optional cooling loop for protection against over-heating

    Combustion fan speed modulation via programmed PCB

    Magnetic protection on motor of automatic feeding system

    Energy saving and safety features due to programmed PCB

    Reliable materials, approved production quality and good finishing

    Stylish electronic control board with well organized function buttons and big LCD screen

    Automatic feeding and firing of walnut coal (up to 20 mm), walnut shell, pirina and pellets

    High heating surface results in higher efficiency among similar products found in the market

    Prismatic full three pass flue circulation with smoke tubes integrated with special design fume retarders

    Detachable high grade cast iron burner system which is the first application in the field saves on service work

    ECO and Night modes

    Room thermostat option

    Large volume for fuel storage

    Auto switch-off when there is no fuel

    Operation status and fault indicators

    Manual ignition (optional auto ignition)

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

       T   e   c   h   n

       i   c   a   l   D   a   t   a

    CT 25 SF CT 40 SF CT 60 SF CT 80 SF CT 100 SF

    kW 30 45 70 90 115

    kcal/h 25.000 40.000 60.000 80.000 100.000

    Models

    Types

    Output

    Caltherm CT SF

    Water Content lt 72 100 140 170 180

    Coal kg 105 120

    Olive Pomace kg 90 100

    Temperature control range   ºC

    Maximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R 1 ¼”

    Connec. for safety inlet/outlet (d g,dd) R

    Filling / draining connection R

    External dimensions Height (H) mm 1155 1240

    H1 mm

    H2 mm

    H3 mm

    Width (W) mm 600 600 632

    W1 mm 1100 1100 1180

    Length (L1) mm 1160 1160 1260 1310 1410

    L2 mm 1110 1160 1260

    L3 mm 890 940 1040

    F lu e outlet d ia meter ( D) m m

    Electrical supply V/Hz

    P ower consum ption ( contin ious ly feed in g) W

    3

    44 to 90 (factory settings)

    ½”

    1325

    511

    343

    328

    718

    ¾”

    1” 1 ¼”

    1” 1 ½”

    100

    40 (recommended)

    155

    130

    460 600

    160 180

    1270

    810

    1005

    230/50

    Fuel Hopper Capacity

  • 8/9/2019 Caldera Kotlovi

    10/29

    Medium Range Automatic Feeding BoilersFor Walnut-Coals And Pirina(Fan Assisted Combustion)

    Up to 290 kWElectronic control with fan speed modulation

     Sophisticated energy saving and safety features

    Caltherm XSF

    Auto switch-off when there is no fuel

    Easy operation and cleaning, high comfort

    Adjustable flue damper on smokehood

    Magnetic protection on motor of automatic feeding system

    Combustion fan speed modulation via programmed PCB

    Energy saving and safety features due to programmed PCB

    Reliable materials, approved production quality and good finishing

    Stylish electronic control board with well organized function buttons and big LCD screen

    Automatic feeding of walnut coal (up to 20 mm), walnut shell, pirina (olive seed) and pellets

    High heating surface results in higher efficiency among similar products found in the market

    Prismatic full three pass flue circulation with smoke tubes integrated with special design fume retardersDetachable high grade cast iron burner system which is the first application in the field saves on service work

    Manual ignition

    ECO and Night modes

    Room thermostat option

    Large volume for fuel storage

    Operation status and fault indicators

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

       T   e   c   h   n   i   c   a   l   D   a   t   a

    CTX 125 SF CTX 150 SF CTX 175 SF CTX 200 SF CTX 250 SF

    kW 145 175 200 230 290

    kcal/h 125.000 150.000 175.000 200.000 250.000

    Models

    Types

    Output

    Caltherm CT XSF

    Water Content lt 325 400 420 474 595

    Coal mm 360

    Olive Pomace mm 310

    Temperature control range   ºC

    Maximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R 3"

    Connec. for safety inlet/outlet (d g,dd) R

    Filling / draining connection R

    External dimensions Height (H) mm 1715

    H1 mm

    H2 mm

    H3 mm

    Width (W) mm

    W1 mm

    Length (L1) mm 1465 1685 1960

    L2 mm 1300 1520 1780

    L3 mm 1030 1250 1420

    Flue outlet diameter (D) mm

    Electrical supply V/Hz

    Power consumpti on (continiously feeding) W

    1250

    2"

    3,2

    44 to 90 (factory settings)

    40 (recommended)

    750 935

    1625 1815

    483

    333

    308

    ¾”

    2 ½”

    1 ¼”

    260

    300

    195

    230

    100

    1730

    1355 1540

    220 280

    380 V / 50 Hz

    1790

    1610

    Fuel Hopper Capacity

    W1

    W

       1   0       1

       H

    L1

    L2

    L3

    D

    D

    d  d

    D  G

    d  g

           H       1

           H       2

           H       3

    R 3/4"

    D

  • 8/9/2019 Caldera Kotlovi

    11/29

    High Range Manual Feeding Steel Boiler (Fan Assisted Combustion)

    Up to 700 kWElectronic control with fan speed modulation

    Sophisticated energy saving and safety features

    Caltherm MF

    Room thermostat option

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Easy operation and cleaning, high comfort

    Adjustable flue damper on smoke hood

    Large fuel loading clearance and combustion chamber

    High-quality thermal isolation materials in boiler covers

    Reliable materials, approved production quality and good finishing

    Adjustable flue damper helps to adjusting combustion rate according to draft

    Stylish electronic control board with well-organized function buttons and big LCD screen

    Complete combustion is performed by properly dimensioned surfaces and combustion air

    High heating surface results in higher efficiency among similar products found in the market

    Cylindrical full three pass flue circulation with smoke tubes integrated with special design fume retarders

        1   5   4

        H 

    W

       H   1

     L1

    L2

    L3

    L4

    D  G

    d g

        H   4

        H   3

        H   2

        D 

    d d

    D D

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Water Content lt 1050 1365 1500 1740 1920 2360

    mm

    mm 1350 1720 1880 1720 1880 2280

    Temperature control range ºC

    Maximum operating temperature ºC

    Minimum return temperature ºC

    Maximum operating pressure bar

    Wat er fl ow /r et ur n co nn ec tio ns ( D) R

    C on ne c. fo r sa fe ty i nl et /o ut le t (d g, dd ) R

    Filling / draining connection R

    External Dimensions Heigth (H) mm

    H1 mm

    H2 mm

    H3 mm

    H4 mm

    W idt h ( W) mm

    Depth (L1) mm 2300 2670 2830 2670 2830 3230

    L2 mm 1980 2350 2510 2350 2510 2910

    L3 mm 1395 1770 1925 1770 1925 2325

    L4 mm 1770 2145 2300 2145 2300 2700

    Flue outlet diameter (D) mm

    Electrical supply V/Hz

    Po we r c ons ump ti on - exc ept pu mp - W 755

    1375 1535

    400 500

    92 92

    500 560

    540 810

    1825 2005

    50 - 90

    100

    3" 4"

    1 ½" 2"

    1"

    2170 2410

    Combustion Chamber Dim. (Ø)

      Width

    940 1040

    CT 300 MF CT 350 MF CT 400 MF CT 450 MF CT 500 MF CT 600 MF

    kW 350 400 465 525 580 700

    kcal/h 300.000 350.000 400.000 450.000 500.000 600.000

    Models Caltherm MF

    Types

    Output

    40 (recommeded)

    Optional, from 3 bar to 5 bar

    400/50

       T   e   c   h   n   i   c   a   l

       D   a   t   a

  • 8/9/2019 Caldera Kotlovi

    12/29

        1   6   6   0

     800

    W

       1   2   4

        H 

    W1

    900

    L3

    L2

    L1

       D 

    D  G

    d g

        H   3

        H   4

        H   1

        H   2

    d d

    D D

    ddol  bos

    High Range Automatic Feeding BoilersFor Walnut-Coals And Pirina(Fan Assisted Combustion)

    Up to 700 kWElectronic control with fan speed modulation

    Sophisticated energy saving and safety features

    Caltherm MSF

    Large volume for fuel storage

    High heating surface results in higher efficiency among similar products found in the market

    Detachable high grade burner system which is the first application in the field saves on service work

    Magnetic protection on motor of automatic feeding system

    Stylish electronic control board with well-organized function buttons and big LCD screen

    Operation status and fault indicators

    Energy saving and safety features due to programmed PCB

    Auto switch-off when there is no fuel

    ECO and Night modes

    Room thermostat option

    Easy operation and cleaning, high comfortAdjustable flue damper on smoke hood

    Reliable materials, approved production quality and good finishing

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Water Content lt 1050 1365 1500 1740 1920 2360

    Fuel Hopper Capacity

    mm

    mm 1350 1720 1880 1720 1880 2280

    Temperature control range ºC

    Maximum operating temperature ºC

    Minimumreturn temperature ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R

    C on ne c. f or s af et y i nl et /o ut le t ( dg ,d d) R

    Filling / draining connection R

    E xt er na l D im en si on s H ei gt h ( H) m m

    H1 mm

    H2 mm

    H3 mm

    H4 mm

    Width (W) mm

    W1 mm

    Depth (L1) mm 2300 2670 2830 2670 2830 3230

    L2 mm 1980 2350 2510 2350 2510 2910

    L3 mm 1395 1770 1925 1770 1925 2325

    Flue outlet diameter (D) mm

    Distance must be applied between hopper

    and internal wallmm

    Electrical supply V/Hz

    Power consumption -except pump-

    (continiously feeding)W

    400 500

    1375

    2470

    1535

    2730

    2255

    40 (recommeded)

    Optional,from3bar to 5 bar

    400/50

    4"

    1 ½" 2"

    1"

    92

    510

    760

    92

    510

    740

    2000 2100

    100

    3"

    2170 2410

    1825 2005

    50 - 90

    Combustion Chamber Dim. (Ø)

      Depth

    470

    940 1040

    CT 300 MSF CT 350 MSF CT 400 MSF CT 450 MSF CT 500 MSF CT 600 MSF

    kW 350 400 465 525 580 700

    kcal/h 300.000 350.000 400.000 450.000 500.000 600.000

    Models Caltherm MSF

    Types

    Output

       T   e   c   h   n   i   c   a   l   D

       a   t   a

    lt

  • 8/9/2019 Caldera Kotlovi

    13/29

    gasification

    boilers

  • 8/9/2019 Caldera Kotlovi

    14/29

    High Efficiency Wood Gasification Boilers(Fan Assisted Combustion)

    Up to 70 kWManual loading

    Exhaust fan speed modulation

     Electronic control

     Improved design with additional features

    Megatherm Plus

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

     L1

    L2 DW

       H   4  

       H 

       H   1  

       H   2

     R   1   /   2   "   

     R   1   1   /   2   "   

    R3/4"

    R1 1/2"

    CE approval on Pressure Equipment Directive (97/23/EC)

    Integrated cooling loop for protection against over-heating

    Energy saving and safety features due to programmed PCB

    Suction fan assisted combustion with modulation on motor speed

    Auto switch to fan maximum speed when loading door is opened

    Additional thermostat for DHW storage tank and outlet for DHW pump

    High quality steel in boiler construction, durable materials on burner and ash pan

    Stylish electronic control board with well organized function buttons and big LCD screen

    New suction fan with higher flow rate and new fan housing with vertical flue outlet result in better performance and minimized smoke loss

    New and larger fuel loading chamber with good resistance to condensation with integrated new by-pass zone (fuel loading capacity

     increased by 15%)

    High efficiency due to fully watercooled smokehood behind fuel loading chamber (total active heating surface increased by 8% compared

    to “Megatherm”)

    Room thermostat option

    Primary and secondary air regulation

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Reduced polluting emissions, small quantity of ash,

    Pyrolytic combustion, suitable for firing dry wood logs

       T   e   c   h   n

       i   c   a   l   D   a   t   a

    Water content lt 85 105 120 145 165 205 240

    Total heating surface m2 2,4 2,7 2,9 3,6 4,0 4,7 6,5

    Fuel container volume dm3 82,0 102,0 116,0 163,0 193,0 275,0 275,0

    Fuel loadi ng cl earance (upper door) cm2

    Flue gas temperature C 210,0 200,0 200,0 200,0 210,0 215,0 215,0

    COemissionclass

    Fluegasmassflow g/s 17,0 23,6 30,2 37,8 47,1 66,0 66,0

    Required draft at chimney Pa 15 - 20 20 - 30 22 - 32 25 - 35 28 - 38 30-40 30 - 40

    mbar 0.15 - 0.20 0.2 - 0.3 0.22 - 0.32 0.25 - 0.35 0.28 - 0.38 0,30-0,40 0.30 - 0.40

    Temperature control range C

    Maximum operating temperature C

    Minimum return temperature C

    Safety system activated at C

    Maximum operating pressure bar

    Water flow/return connections R

    Cooling loop connections R

    Filling / draining connection RExternaldimensions

    Height (H) mm 1155 1155 1155 1265 1265 1365 1520

    H1 mm 70 70 70 70 70 70 70

    H2 mm 200 200 200 200 200 200 200

    H4 mm 1075 1075 1075 1185 1185 1285 1485

    Width (W) mm 615 615 615 680 680 680 680

    Length (L1) mm 1180 1300 1400 1400 1475 1660 1740

    Length (L2) mm 790 910 1010 1010 1140 1285 1285

    Fl ue out le td iam et er (D ) mm

    Electricalsupply

    Powerconsumption W 38 38 38 48 48 48 48

    Fueltype

    Combustionperiodat maxload h

    Requestedfuel parameters

    Allowablewoodlog size

    Maximumwoodlog length cm 45,0 55,0 65,0 65,0 75,0 92,0 92,0

    Diameterbetween7cm -15cm

    1 1/2" 2"

    3/4"

    1/2"

    159 180

    230V/50Hz

    Wood logs

    6 to8

    Allowablewatercontent12- 20%

    Averagecalorificvalue15.000- 17.000kJ/kg

    3

    1150 1525 2000

    3

    60-90

    100

    60(recommended)

    95

    CEIdentificationnumber

    Fuels

    Output kW 18 25 32 40 50 70 100

    Efficiency % 80

    Model Megatherm Plus

    1783 -PED -028

    Woodlogs

    Ranges MTP 18 MTP 25 MTP 32 MTP 40 MTP 50 MTP 70 MTP 100

  • 8/9/2019 Caldera Kotlovi

    15/29

       T   e   c   h   n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Pyrocal

    Up to 80 kWManual loading

    Exhaust fan speed modulation

     Electronic control

     Improved design with additional features

     L1

    L2

       H   1

        H   3

        7   5

    R1 1/2"

    R1 1/2"

     

       D 

       H 

       H   2

        H   4

     w

    R 3/4 "

    R 1/2"

    Integrated cooling loop for protection against over-heating

    Manually activated new smoke by-pass section with minimized loss

    Large and prismatic fuel loading particularly sized for better gasification process

    High quality steel in boiler construction, durable materials on burner and ash pan

    Reduced polluting emissions, small quantity of ash ( CO less than EN 303/5 class 3)

    CE approval on EN 303/5 Class 3 Pyrolytic combustion, suitable for firing dry wood logs

    Stylish electronic control board with well organized function buttons and big LCD screen

    New suction fan with interated fan housing with vertical flue outlet results in better performance

    High efficiency due to increased and smoke tubed water heating surfaces (over EN 303/5 class 3)

    Operation status and fault indicators, energy saving and safety features due to programmed PCB

    Exhaust fan assisted combustion with modulation on motor speed enables good performance even with old chimney installations

    Effective primary and secondary air regulation with good combustion air distribution result in high gasification and low condensation ratein fuel loading chamber

    Buffer probe

    Three-way valve option

    Auto switch-off when there is no fuel

    Room thermostat connection

    CE approval on Pressure Equipment

    Directive (97/23/EC)

    High Efficiency Wood Gasification Boilers(Fan Assisted Combustion)

    Water content lt 85 105 120 145 165 205

    Total heating surface m2 2,4 2,7 2,9 3,6 4,0 6,0

    Fuel container volume dm3 85,0 105,0 120,0 170,0 200,0 285,0

    Fuel loading clearance (upper door) cm2 2140

    Flue gas temperature C 190,0 190,0 200,0 210,0 220,0 220,0

    COemissionclass

    Flue gas mass flow g/s 17,0 23,6 30,2 37,8 47,1 66,0Required draft at chimney Pa 15-20 20 - 30 22 - 32 25 - 35 28 - 38 30-40

    mbar 0.15 - 0.20 0.2 - 0.3 0.22 - 0.32 0.25 - 0.35 0.28 - 0.38 0,30-0,40

    Temperature control range C

    M axi mum operating te mpe rature C

    Minimum return temperature C

    Safety system activated at C

    Maximum operating pressure bar

    Water flow/return connections R 2"

    Cooling loop connections R

    Filling / draining connection R

    External dimensionsHeight (H) mm 1170 1170 1170 1270 1270 1380

    H1 mm 110 110 110 110 110 110

    H2 mm 195 195 195 195 195 195

    H3 mm 880 880 880 980 980 1045

    H4 mm 830 830 830 960 960 1040

    Width (W) mm 612 612 612 672 672 672

    Length (L1) mm 1050 1170 1270 1270 1350 1575

    Length (L2) mm 770 885 990 990 1070 1260

    Flue outlet diameter (D) mm 180

    Electrical supply

    Power consumption W 38 38 38 48 48 48

    Fuel type

    Combustion periodat max load hRequested fuel parameters

    Allowable woodlog size

    Maximum wood log length cm 45,0 55,0 65,0 65,0 75,0 92,0

    1230 1650

    EN 303- 5 CLASS 3

    60- 90

    100

    60(recommended)

    95

    3

      1 1/2"

    3/4"

     1/2"

    159 168

    230 V / 50 Hz

    Wood logs

    6 to 8

    Allowable water content 12- 20%

    Average calorific value 15.000 - 17.000 kJ/kg

    Diameter between7 cm - 15cm

    CE Identificationnumber

    Ranges PYR 22 PYR 30 PYR 38 PYR 48 PYR 60 PYR 80

    Fuels

    Output kW 22 30 38 48 60 80

    Efficiency %

    Model Pyrocal1783- PED - 028

    Wood logs

    EN 303- 5 CLASS 3

  • 8/9/2019 Caldera Kotlovi

    16/29

    ITG 25 ITG 32 ITG 40 ITG 50 ITG 70 ITG 100

    kW 25 32 40 50 70 100

    lt 90 100 110 132 170 215

    m2 2,74 3,05 3,83 5,04 7,15 10,00

    dm3 106,7 128,5 187,8 304,9 402,9 520,0

    cm2 1650

    C 210,0 200,0 200,0 200,0 210,0 215,0

    g/s 17,0 23,6 30,2 37,8 47,1 66,0Pa 15 - 20 20 - 30 22 - 32 25 - 35 28 - 38 30 - 40

    mbar 0.15 - 0.20 0.2 - 0.3 0.22 - 0.32 0.25 - 0.35 0.28 - 0.38 0.30 - 0.40

    C

    C

    C

    C

    bar

    R

    R

    R 3/4"

    mm 1440 1440 1540 1660 1740 1840

    mm 125 125 125 125 125 125

    mm 380 380 380 380 380 370

    mm 900 900 1000

    mm 1335 1335 1435 1555 1655 1742

    mm 586 586 586 666 666 666

    mm 860 960 1110 1210 1360 1510

    mm 1180 1280 1430 1530 1680 1865

    mm

    W

    h

    cm 45,0 55,0 70,0 80,0 95,0 110,0

    2"

    Integra

    1783- PED-028

    Woodlogs

    1120

    PrEN303/5:2011Class5

    159 180

    230V/ 50Hz

    65-90

    100

    65(recommended)

    95

    3

    11/2"

    Diameterbetween7cm -15cm

    110 330

    W ood log s

    6to8

    Allowablewatercontent12- 20%

    Averagecalorificvalue 15.000-17.000 kJ/kg

    3/4"

    1/2"

    Model

    CEIdentification number

    Ranges

    Fuels

    Output

    Watercontent

    Totalheating surface

    Fuelcontainervolume

    Fuelloadingclearance (upperdoor)

    Fluegas temperature

    COemission class

    Fluegasmassflow

    Requireddraftat chimney

    Temperaturecontrol range

    Maximumoperatingtemperature

    Minimumreturntemperature

    Safetysystemactivated at

    Maximumoperatingpressure

    Waterflow/returnconnections

    Cooling loopconnections

    Filling /draining connectionExternaldimensions

    Height(H)

    H1

    H2

    H3

    H4

    Width (W)

    Length(L1)

    Length(L2)

    Flueoutlet diameter(D)

    Electricalsupply

    Powerconsumption

    Fuel type

    Combustion period atmax load

    Requestedfuel parameters

    Allowablewoodlog size

    Maximumwoodlog length

    New Generation Wood Gasification Boilers(Fan Assisted Combustion)

    Up to 100 kW Electronic control

    Manual loading

    Exhaust fan speed modulation

     High efficiency and low polluting emissions

    Integra

     

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

       T   e   c   h   n   i   c   a   l   D   a   t   a

    CE approval on Pressure Equipment Directive (97/23/EC)

    New burner design with good combustion air distribution

    Integrated cooling loop for protection against over-heating

    Additional thermostat for DHW storage tank and outlet for DHW pump

    Three front doors for better ignition, operation and cleaning of the boiler

    Reduced polluting emissions, small quantity of ash ( CO less than EN 303/5 class 5)

    Stylish electronic control board with well organized function buttons and big LCD screen

    Auto activation of exhaust fan to maximum speed when door is open to minimize smoke loss

    Operation status and fault indicators, energy saving and safety features due to programmed PCB

    High efficiency due to increased and smoke tubed water heating surfaces ( over EN 303/5 class 5 )

    Large fuel loading chamber with dry internal surface particularly sized for better gasification process

    New suction fan with higher flow rate and new fan housing with vertical flue outlet result in better performance

    Exhaust fan assisted combustion with modulation on motor speed enables good performance even with old chimney installations

    Dry internal surface by double wall in fuel loading chamber, results in less condensation rate and better boiler protection, as well as higher

    gasification ratio and easier surface cleaning

    Room thermostat connection

    Auto switch-off when there is no fuel

    Primary and secondary air regulation

    New by-pass principle with minimized smoke loss

    Pyrolytic combustion, suitable for firing dry wood logs

    W

       H

    L2

    D L1

       H   4

       H   3

       H   2

       8   1 R 3/4"

       H   1

    R 1 1/2"

    R 1 1/2"

    R 1/2"

  • 8/9/2019 Caldera Kotlovi

    17/29

    steel hot water boilers

     for gas, oil or dual

    fuel burners

  • 8/9/2019 Caldera Kotlovi

    18/29

    Steel BoilersFor Forced Draught Burners

    Up to 1200 kWFull three pass circulation

    Compact dimensions

    High efficiency

    Suitable for hot water and low temperature heating installations

    Caltech 3

     

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

       T   e   c   h   n   i

       c   a   l   D   a   t   a

    Stainless steel fume retardes in third passage smoke tubes

    Available for forced draught gas or oil burners, dual fuel burners.

    Suitable for hot water heating circuits and low temperature systems,

    Building cascade systems up to 5 boilers, and zone control solutions

    Full three pass circulation principle results in low particul emissions at flue outlet

    Smooth operation due to properly sizing of combustion chamber and flue passages,

    Good combustion results due to lowered heat input rate inside combustion chamber,

    Integration for building automatization systems, management of modulation burners

    Standardproduction for 3 bars operating pressure, higher operating pressures available upon request

    High quality in front door refractory design and body insulation boards result in minimized stand-by loses,

    Long operation life thanks to good material used in construction and minimized themal stresses inside boiler body

    Control panel alternatives from basic two stage burner control to full automatic control with outside temperature compensation

    Non-condensing operation for low temperature heating systems, thanks to special design for mixing return water and hot water

    inside boiler at boiler inlet area

    High efficieny ( 2 stars ),

    Prismatic external design,

    Compact dimensions due to cylindrical body design,

    Front door available for both left or right side hinging

     W

    S

     L

       D 

    R F

    FD

        H

        H   1

    Rated

    output

    Flow/return

    (F/R)

    Safety

    (S)

    Fill/drain

    (FD)

    Flue

    (D)

    Flue gas

    resistance

    Water side

    resistance

    (kW) DN (mm) H (mm) H1 (mm) W (mm) L (mm) (mbar) (mbar)

    TH3 60 70 50 1 1/4" 3/4" 200 1005 690 875 1110 0,55 1,8

    TH3 80 93 50 1 1/4" 3/4" 200 1005 690 875 1340 0,65 2,2

    TH3 100 116 50 1 1/4" 3/4" 200 1005 690 875 1640 0,75 2,8

    TH3 150 175 65 1 1/4" 3/4" 200 1140 825 1010 1655 0,80 4,0

    TH3 200 232 65 1 1/4" 3/4" 200 1140 825 1010 1955 0,95 5,0

    TH3 250 290 65 1 1/4" 3/4" 300 1215 850 1085 1955 1,15 6,5

    TH3 300 350 80 1 1/4" 3/4" 300 1240 925 1160 1955 1,20 8,0

    TH3 350 407 80 1 1/4" 3/4" 350 1385 1050 1285 1960 1,60 10,0

    TH3 400 465 80 1 1/2" 1" 350 1385 1050 1285 2160 1,80 11,0

    TH3 450 525 100 1 1/2" 1" 350 1485 1150 1385 2160 2,30 12,0

    TH3 500 580 100 1 1/2" 1" 350 1485 1150 1385 2360 2,50 15,0

    TH3 600 700 100 1 1/2" 1" 400 1635 1300 1540 2560 2,80 15,0

    TH3 700 815 125 2" 1" 400 1685 1350 1660 2660 3,10 16,5

    TH3 800 930 125 2" 1" 450 1835 1500 1750 2760 3,50 18,0

    TH3 900 1050 125 2" 1" 450 1885 1500 1800 2860 3,70 19,0

    TH3 1000 1165 125 2" 1" 450 1935 1550 1850 2960 4,00 20,0

    ModelExternal Dimensions

  • 8/9/2019 Caldera Kotlovi

    19/29

    biomass

    boilers

  • 8/9/2019 Caldera Kotlovi

    20/29

       T   e   c   h   n   i   c   a   l   D   a   t   a

    Bio-Pack ES & EXCompact pellet boilers

    Up to 40 kW

    Automatic ignition

     Very compact dimensions

    High efficiency

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Model BP 18 BP 24 BP 32 BP 40

    Fuels

    Output kW 18 24 32 40

    Efficiency %

    Flue circulation

    Draught

    Maximum operating temperature C

    Maximum operating pressure bar

    Water flow/return connections G

    Filling / draining connection G

    Burner design

    Fuel container capacity kg 45 52 75 90

    External dimensions

    W mm

    H mm 1365 1490 1600 1700

    H1 mm 1240 1365 1450 1550

    H2 mm 1085 1210 1310 1410

    H3 mm

    L mm

    L1 mm

    D mm

    Wood pellets 6 - 8 mm

    EN 303/5 Class 4

    Vertical

    3

    1/2" (male)

    Stainless steel pot

    Exhaust fan at flue outlet

    100

    545 600

    520 580

    128

    1 " (male)

    730 900

    325 375

               L           1

    W

       H

    L

       H   3

       H   2

       H   1

      R 

       D

     D  G

    D  D

    Auto switch-off when there is no fuel

    Fire protection system, safety against back burning

    Low polluting emissions (less than eN 303/5 Class 4)

    Two models with different features and control options

    Very compact dimensions to match any installation space

    High heating surface with vertical flue circulation principle

    Exhuast fan speed control via encoder ensures a very safe operation

    Burner made of special stainless steel sheetmetal with high heat resistance

    Exhaust fan speed modulation in respect with desired outlet water temperature and flue gas temperature

    Automatic ignition

    Room thermostat control option

    High water efficiency (above 85%)

    PID control, adjustable boiler outputs

    BIOPACK

    ES

    YES

    YES

    YES

    YES

    MANUAL

    YES

    -

    YES

    YES

    YES

    NO

    FEATURES

    Electronic ignition

    PID control

    Exhaust fan speed modulation

    Exhuast fan operation control (encoder)

    Burner cleaning

    Smoke tube cleaning (manual activation)

    Smoke tube cleaning (automatic)

    Fire protection

    Flue thermostat

    Room thermostat connection

    Outdoor temperature sensor 

    Buffer tank3-way valveDHW pump

    BIOPACKEX

    YES

    YESYES

    YES

     AUTOMATIC-

    YES

    YES

    YES

    YES

    YES

    Central heating pump

    * Outputs refer to system capability, accessories are not included in delivery

    YES

    YES

    NO

    YES

    YES

    YES

    YESNO

    USER INTERFACE

    OUTPUTS*

  • 8/9/2019 Caldera Kotlovi

    21/29

    cast iron boilers

    for solid fuels

  • 8/9/2019 Caldera Kotlovi

    22/29

    Solitherm SHigh Efficiency Cast Iron Boilers For Solid Fuels(Natural Draught)

    Up to 56 kWManual loading

    New and modern design

    Patented flue gas circulation principle

     530

       9   7   0

        1   0   5   0

     L1

    L2

       D 

    R1 1/2"

    R1 1/2"

        1   8   0

        2   0   5

        7   3   5

        8   9   0

    R1/2"

    Suitable for firing wood logs, brown coal, lignite, and coke

    High heat transfer rate due to finned design of cast iron sections,

    Compact and high efficiency solutions for manually loaded boilers

    Water-cooled bottom grate for easy warm-up period and high energy

    Manual adjustment on secondary air for better combustion and flue emissions

    Natural draught combustion controlled by primary air regulation via thermostatic controller

    EN-GJL 200 grade grey cast iron made boiler body, approved production quality and good finishing

    Advanced flue gas circulation with high efficiency due to new patented flue gas circulation by Caldera,

    High corrosion resistance and long operation life due to flexible casting technology and cast iron boiler elements

    Faster fire-up intervals between fuel re-loads due to easy access of air inside combustion chamber, thanks to vertical finned combustion

    chamber surfaces,

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

       T   e   c

       h   n   i   c   a   l   D   a   t   a

    Scaled thermometer to monitor boiler outlet temperature

    Optional cooling loop for protection against over-heating

    CE approval on Pressure Equipment Directive (97/23/EC)

    Water Content lt 27 32 37 42 52 52

      Height mm

    Width mm

    Depth mm 220 320 420 520 620 720

    Fuel loading clearance (uppe r door) mmxmm

    M ax . F ue l l oa din g h eig ht (fo r l og wo od ) m m

    Temperature control range ºC

    Maximum operating temperature ºC

    Minimum return temperature ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R

    Filling / draining connection R

    External dimensions Length (L1) mm 525 625 725 825 925 1025

    L2 mm 380 480 580 680 780 880

    F lu e o utl et di am ete r ( D) m m

    425

    315

    322 x 318

    400

    ½ "

    160

    50 - 90

    100

    50 (recommended)

    4

    1 ½"

    ST 3 S ST 4 S ST 5 S ST 6 S ST 7 S ST 8 S

    Number of sections pcs. 3 4 5 6 7 8

    (Coal) kW 17 27 34 41 48 56

    (Wood) kW 15 23 30 36 43 51

    Model

    Types

    Nominal Power

    Solitherm S

    Combustionchambe r

    dimensions

  • 8/9/2019 Caldera Kotlovi

    23/29

    Up to 70 kWManual loading

     Electronic control with fan speed modulation

    New and modern design

     Patented flue gas circulation principle

    Solitherm FHigh Efficiency Cast Iron Boilers For Solid Fuels(Fan Assisted Combustion)

    CE approval on Pressure Equipment Directive (97/23/EC)

    Suitable for firing wood logs, brown coal, lignite, and coke

    Energy saving and safety features due to programmed PCB

    High heat transfer rate due to finned design of cast iron sections,

    Compact and high efficiency solutions for manually loaded boilers

    Water-cooled bottom grate for easy warm-up period and high energy

    Stylish electronic control board with well organized function buttons and big LCD screen

    EN-GJL 200 grade grey cast iron made boiler body, approved production quality and good finishing

    Advanced flue gas circulation with high efficiency due to new patented flue gas circulation by Caldera,

    High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

    Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

    High corrosion resistance and long operation life due to flexible casting technology and cast iron boiler elementsFaster fire-up intervals between fuel re -loads due to easy access of air inside combustion chamber, thanks to vertical finned combustion

    chamber surfaces,

    Room thermostat option

    Operation status and fault indicators

    Auto switch-off when there is no fuel

    Night and ECO modes to save energy

    Optional cooling loop for protection against over-heating

       T   e   c   h   n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

     530

       1   0   0

        9   7   0

     W

    L2

    L1

       D 

    R1 1/2"

    R1 1/2"

        1   8   0

        2   0   5

        7   3   5  

       8   9   0

    R1/2"

    Water Content lt 27 32 37 42 52

      Height mm

    Width mm

    Depth mm 420 520 620 720 920

    F ue l l oa di ng cl ea ra nce ( up pe r do or ) mmx mm

    M ax . F ue l l oa di ng h ei gh t ( fo r l og wo od ) m m

    Temperature control range   ºCMaximum operating temperature   ºC

    Minimum return temperature   ºC

    Maximum operating pressure bar

    Water flow/return connections (D) R

    Filling / draining connection R

    E xt er na l d im en si on s W id th ( W) m m

    Length (L1) mm 725 825 925 1025 1225

    L2 mm 580 680 780 880 1080

    F lue out le t d ia me te r ( D) mm

    Electrical supply V/Hz

    Power consumption W

    ½"

    50 - 90

    322 x 318

    425

    400

    315

    4

    1 ½"

    8243

    230/50

    160

    670 740

    50 (recommended)

    100

    ST 5 F ST 6 F ST 7 F ST 8 F ST 10 F

    Number of sections pcs. 5 6 7 8 10

    (Coal) kW 34 41 48 56 70

    (Wood) kW 30 36 43 51 65Nominal Power

    Model

    Types

    Solitherm F

    Combustionchamber

    dimensions

  • 8/9/2019 Caldera Kotlovi

    24/29

    radiators

  • 8/9/2019 Caldera Kotlovi

    25/29

    Name Type

    Victoria

    VictoriaVictoria

    Victoria

    600

    600800

    800

    Feet

    MiddleFeet

    Middle

    Maximum efficiency

     Excellent heat transfer properties

     Unique high quality old fashioned castiron radiator

    Long lasting usage

     Easy installation

    VictoriaCast Iron Radiator

    HeatingSurface

    2(m )

    HeatOutput*

    (W)

    HeatOutput*(kcal/hr)

    HeatOutput*(BTU/hr)

    0,31 147 126 500

    0,31 147 126 5000,47 227 195 774

    Height(mm)

    770

    710970

    910

    DistanceBetweenCenter (mm)

    600

    600800

    800

    Width(mm)

    225

    225225

    225

    Water Content

    (I)

    Weight(kg)

    3,2 11,7

    3,2 10,64 14,6

    4 13,5 0,47 227 195 774

       T   e   c   h   n   i   c   a   l   D   a   t   a

    * Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

    Elegance look of its classic styling ideal for both traditional and contemporary buildings

    Radiant Heat combined with convected heat provides a warm comfortable environment

    The advantages of slow cool–down ensure extended warming time.

    It performs as a shield  for cold air coming  from outside walls and windows

    Available in and two heights 600mm and 800mm.

    Durable cast iron prevents the product  from denting, bending and coming apart for years.

    Pressure tested ready  for plumbing into your new or existing heating system.

    Coloured with primary coating RAL 7022.

    L

       9   7   2

    225

       1

       1

       1

       8   0   0

    250L = 760 for 10 sections

    L 225

       7   7   2

       6   0   0

       1

       1

       1

    250L = 760 for 10 sections

    Nipple(inch)

    1" 1/4

    1" 1/41" 1/4

    1" 1/4

  • 8/9/2019 Caldera Kotlovi

    26/29

    Stainless Steel Design Radiators

    Stainless Steel Design Radiators

    PoloStainless Steel Design Radiators

    Zephyr

    E Type

    CadenceStainless Steel Design Radiators

    Technical Data

    Polo Watts? 50°C ? 50°C

    Polo 09656-15 986 560 50 420 95-110 127-142 15+2 412 479 40x10+Ø32

    Polo 15056-23 1486 560 50 420 95-110 127-142 23+2 631 734 40x10+Ø32

    KCalHeight W id th D ep th C en te r to

    CenterKind of Tubes

    mm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Technical Data

    KCa l Watts

    ? 50°C ? 50°C

    Zephyr 100-10 1000 490 30 450 95-110 105-120 10 570 40x10+40x20

    Zephyr 200-05 2000 240 30 200 95-110 105-120 5 570 40x10+40x20

    Zephyr 200-10 2000 490 30 450 95-110 105-120 10 1140 40x10+40x20

    Zephyr

    490

    490

    1023

    Height W id th D ep th C en te r to

    CenterKind of Tubes

    mm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Technical Data

    KCalCadence B Watts? 50°C ? 50°C

    Cadence 70B11 700 510 65 510 100-115 75-90 125-140 11 575 668 50x30

    Cadence 100B10 1000 465 65 465 100-115 75-90 125-140 10 746 867 50x30

    Cadence 150B11 1500 510 65 510 100-115 75-90 125-140 11 1231 1431 50x30

    Height W id th D ep th C en te r to

    Center

    Kind

    of Tubesmm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Back to

    Wall

    KCal Watts

    ? 50°C ? 50°C

    E-type 975 800 75 80 95-110 135-150 18+2 670 780 40x20+40x40

    E-type Height W id th D ep th C en te r t oCenter

    Kind of Tubesmm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Technical Data

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

  • 8/9/2019 Caldera Kotlovi

    27/29

    Aluminum Design RadiatorsStainless Steel Design Radiators

    Stainless Steel Design Radiators

    Caftan

    Impulse

    Dora

    Excel

    Aluminum Design Radiators

    Caftan 345 790 500 45 380 95-110 105-120 12 294 342 40x10+40x20

    Caftan 456 940 500 45 3 80 9 5- 110 1 05 -12 0 15 367 4 27 4 0x 10 +4 0x 20

    Caftan Watts? 50°C ? 50°C

    KCal

    Technical Data

    Height W id th D ep th C en te r to

    CenterKind of Tubes

    mm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Impulse 100 1000 460 57 414 95-110 137-152 10+2 667 775 D32-Ø32

    Impulse 150 1500 460 57 414 95-110 137-152 10+2 1000 1163 D32-Ø32

    Impulse 200 2000 460 57 414 95-110 137-152 10+2 1333 1550 D32-Ø32

    Impulse Watts? 50°C ? 50°C

    KCal

    Technical Data

    Height Width D epth Cente r to

    CenterKind of Tubes

    mm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    Dora 1500 280 31 140 75-90 110-130 2 354

    2000 280 31 105-120 15 473 550

    Watts

    ? 50°C ? 50°C

    KCal

    Dora 140 75-90

    Dora

    412

    Technical Data

    Height W id th D ep th C en te r to

    Centermm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    550 1100 115 1037 24 804 936

    550 1600 115 12 1206 1404

    Watts

    ? 50°C ? 50°C

    KCal

    1537

    SerbestExcel 55ALW110-12

    Excel

    Excel 55AL160-12 Serbest

    Serbest

    Serbest

    Technical Data

    Height W id th D ep th C en te r to

    Centermm mm mm

    Center

    to Wall

    Front to

    Wall

    Number

    of Tubes

    * Caldera Heating Group reserves the right t o make changes on product dimensions and general view without prior notice

  • 8/9/2019 Caldera Kotlovi

    28/29

    Caltherm WhiteWhite Towel Radiators

    Caltherm ChromeChrome Towel Radiators

    * Caldera Heating Group reserves the rihgt to make changes on product dimensions and general view without prior notice

    Caltherm White / Technical Data

    * Caldera Heating Group reserves the rihgt to make changes on product dimensions and general view without prior notice

    Caltherm Chrome / Technical Data

    ModelWidth

    (mm)

    Height

    (mm)

    Connection

    Axis

    (mm)

    Pipe

    Quantity

    Tubes

    Diameter 

    Water 

    Content

    Heating

    Surface

    (m2)

    Weight

    (kg)kcal/h watt kcal/h watt

    407 400 700 355 13 22 2,67 0,46 3,60 274 319 276 321

    408 400 800 355 14 22 3,00 0,50 4,00 308 358 310 361

    410 400 1000 355 16 22 3,50 0,65 4,80 359 418 362 421

    411 400 1100 355 18 22 3,90 0,67 5,30 401 466 404 470

    412 400 1200 355 20 22 4,30 0,80 5,90 429 499 432 502

    414 400 1400 355 24 22 5,10 0,94 7,00 524 609 528 614416 400 1600 355 27 22 5,80 1,07 7,90 596 693 600 698

    418 400 1800 355 32 22 6,70 1,24 9,10 644 749 646 751

    507 500 700 455 13 22 3,00 0,55 4,20 308 358 310 361

    508 500 800 455 14 22 3,40 0,64 4,70 349 406 352 409

    510 500 1000 455 16 22 4,00 0,76 5,60 411 478 414 481

    511 500 1100 455 18 22 4,40 0,80 6,10 452 526 455 529

    512 500 1200 455 20 22 4,90 0,94 6,80 503 585 507 590

    514 500 1400 455 24 22 5,80 1,11 8,10 596 693 600 698

    516 500 1600 455 27 22 6,60 1,26 9,20 678 789 683 794

    518 500 1800 455 32 22 7,70 1,46 10,60 768 893 770 896

    607 600 700 555 13 22 3,50 0,64 4,80 359 418 362 421

    608 600 800 555 14 22 3,80 0,74 5,40 390 454 393 457

    610 600 1000 555 16 22 4,40 0,87 6,30 452 526 455 529

    611 600 1100 555 18 22 5,00 0,92 7,00 513 597 517 601

    612 600 1200 555 20 22 5,60 1,07 7,80 575 669 579 673

    614 600 1400 555 24 22 6,60 1,28 9,20 678 789 683 794

    616 600 1600 555 27 22 7,50 1,44 10,40 770 896 776 902

    618 600 1800 555 32 22 8,70 1,68 12,10 886 1030 888 1033

    Heat Output

    White / CurveWhite / StraightWhite Towel Radiators

    ModelWidth

    (mm)

    Height

    (mm)

    ConnectionAxis(mm)

    Pipe

    Quantity

    Tubes

    Diameter 

    Water 

    Content

    HeatingSurface

    (m2)

    Weight

    (kg)kcal/h watt kcal/h watt

    407 400 700 355 13 22 2,67 0,46 3,60 192 223 193 224

    408 400 800 355 14 22 3,00 0,50 4,00 216 251 217 252

    410 400 1000 355 16 22 3,50 0,65 4,80 252 293 253 294

    411 400 1100 355 18 22 3,90 0,67 5,30 280 326 282 328

    412 400 1200 355 20 22 4,30 0,80 5,90 300 349 302 351

    414 400 1400 355 24 22 5,10 0,94 7,00 367 427 369 429416 400 1600 355 27 22 5,80 1,07 7,90 417 485 420 488

    418 400 1800 355 32 22 6,70 1,24 9,10 451 525 452 526

    507 500 700 455 13 22 3,00 0,55 4,20 216 251 217 252

    508 500 800 455 14 22 3,40 0,64 4,70 244 284 246 286

    510 500 1000 455 16 22 4,00 0,76 5,60 288 335 290 337

    511 500 1100 455 18 22 4,40 0,80 6,10 316 368 319 371

    512 500 1200 455 20 22 4,90 0,94 6,80 352 409 355 413

    514 500 1400 455 24 22 5,80 1,11 8,10 417 485 420 488

    516 500 1600 455 27 22 6,60 1,26 9,20 474 551 478 556

    518 500 1800 455 32 22 7,70 1,46 10,60 538 626 539 627

    607 600 700 555 13 22 3,50 0,64 4,80 252 293 253 294

    608 600 800 555 14 22 3,80 0,74 5,40 273 317 275 320

    610 600 1000 555 16 22 4,40 0,87 6,30 316 368 319 371

    611 600 1100 555 18 22 5,00 0,92 7,00 359 418 362 421

    612 600 1200 555 20 22 5,60 1,07 7,80 403 469 406 472

    614 600 1400 555 24 22 6,60 1,28 9,20 474 551 478 556

    616 600 1600 555 27 22 7,50 1,44 10,40 539 627 543 632

    618 600 1800 555 32 22 8,70 1,68 12,10 620 721 622 723

    Chrome Towel RadiatorsChrome / Straight

    Heat Output

    Chrome / Curve

  • 8/9/2019 Caldera Kotlovi

    29/29

    Croatia

    Kosova

    LithuaniaEurope's choice...

    Portugal

    Slovakia

    Ireland

    maviakým