CABLE MANAGEMENT SYSTEMS Export Catalogue 2004 Section 2 - Steel

DIETZEL UNIVOLT Products are available from:

MARYLAND METRICSP.O. Box 261 Owings Mills, MD 21117 USA phones: (410)358-3130 (800)638-1830 faxes: (410)358-3142 (800)872-9329 email: [email protected] web: http://mdmetric.com

Installation Systems used worldwideThe UNIVOLT steel range of products has a long establishedreputation for superior quality and performance. These rangeshave been developed to suit the demand of today’s industrialrequirements.

From refurbishments to new build projects UNIVOLT offers awide range of steel products for electrical installations underone roof.

The success of UNIVOLT is based on its on-going commitmentto innovation, research and development, product reliability anda professional service to all its customers.

This new catalogue is designed to be of assistance towholesalers, contractors, architects and specifiers in theselection and application of our cable managment systems formodern electrical installations.

London Tower Bridge

Esplanade, Theatre on the Bay, Singapore

Opera House, Sydney

Cern Geneva

UNO City, ViennaII

1Available from: MARYLAND METRICS http://6mm.com

TABLE OF CONTENTS

UNIVOLT - CABLE MANAGEMENT SYSTEMS

page

STEEL TRUNKING & Fittings 2-5

STEEL LIGHTING TRUNKING & Fittings 6-8

STEEL LIGHT DUTY TRAY & Fittings 9-10

STEEL MEDIUM RETURN TRAY & Fittings 11-12

STEEL HEAVY RETURN TRAY & Fittings 13-14

STEEL TRAY SUPPORT FITTINGS 14

STEEL FIXINGS 15-16

STEEL CHANNEL SUPPORT & NUTS 17

STEEL CHANNEL BRACKETS & FITTINGS 18-19

STEEL LIGHTING CHANNEL FITTINGS 20

STEEL CAVITY FLOOR TRUNKING 21Cavity Floor Service Outlet Box & Service Outlet Plates 21-22

STEEL UNDERFLOOR TRUNKING 23Underfloor Service Outlet Box 23

STEEL FLUSH FLOOR TRUNKING 24Flush Floor Service Outlet Box 24

STEEL SHALLOW FLUSH FLOOR TRUNKING 25Shallow Flush Floor Service Outlet Box 25

SERVICE OUTLET SOCKETS & PLATESfor Flush Floor, Shallow Flush Floor and Underfloor Boxes. 26

STEEL SKIRTING TRUNKING 27

STEEL DADO TRUNKING 28

STEEL BENCH TRUNKING 29

STEEL WIRE BASKET TRAY & Fittings 30-31

Conditions of Sale 32

Other UNIVOLT® Cable Management Products III

2 Available from: MARYLAND METRICS http://6mm.com

STEEL TRUNKINGProduct Info:Supplied in standard 3 metre lengths complete with a cover fitted with speed-lock turnbuckle fixing system (6 per length), a connector pack comprising of 2 connector plates plus 4 M5x6 Combihead earthing screws Specifications: The Trunking range is manufactured to BS4678 Part 1, 1978 and a Quality Management System to ISO 9001:2000.Material: Made from hot dipped galvanised sheet / coil steel (i.e. Pre-Galvanised) to BS EN10142:1991 Finish: Self coloured galvanised to Class 3 Heavy Protection BS4678 Part 1.Sizes & Fittings: Standard stock sizes are from 50x50 to 150x150 mm, together with the complete range of fittings. All fittings are supplied with a screw fix lid, connectors and M5x6 fixing screws. All holes are bushed.

Options available to special order:1) Covers - screw-fix and security screw fix covers2) Finish - polyester powder coated3) Larger sizes - from 225x50 to 300x300 mm (9x2 to 12x12 inches)4) Compartments - 2 to 4 compartments - equal or unequal

STEEL TRUNKING - Single CompartmentWall Weight

Size mm inches Part No. Thickness mm kg/3mt

50x50 2x2 CT22 0.9 5.475x50 3x2 CT32 1.2 6.975x75 3x3 CT33 1.2 8.4100x50 4x2 CT42 1.2 8.4100x75 4x3 CT43 1.2 9.6100x100 4x4 CT44 1.2 11.1150x50 6x2 CT62 1.2 11.7150x75 6x3 CT63 1.2 13.2150x100 6x4 CT64 1.2 14.4150x150 6x6 CT66 1.4 18.3

TRUNKING - Spare Cover

Standard lengths - 3 metres, fitted with speed lock fixings

WeightSize mm Part No. kg/3mt

50 CT22L 1.575 CT33L 1.8100 CT44L 2.4150 CT66L 4.5

TRUNKING - Separators

Supplied in 3 metre lengthsWeight

Size mm Part No. kg/3mt

50 LD22 1.275 LD33 1.5100 LD44 1.8150 LD66 2.4

UNIVOLT - CABLE MANAGEMENT SYSTEMS

3Available from: MARYLAND METRICS http://6mm.com

Fixings

For use with the standard trunking

Part Std.Description No. Pack

Speedlock fixings SF 10 Connector fixings (M5x6 Combi Screws) CF 100Earth Links EL 10 Zinc Rich Paint ZP 1 Ltr Tamperproof Screws TS 100

Part Std.Size mm No. Pack

50x50 CP22 175x50 CP32 175x75 CP33 1 100x50 CP42 1 100x75 CP43 1 100x100 CP44 1 150x50 CP62 1 150x75 CP63 1 150x100 CP64 1 150x150 CP66 1

Connector

Supplied with 2 connector plates plus 4 M5x6 drive screws with earth serrations

90° Top Cover BendPart Std.

Size mm No. Pack

50x50 NGT22 175x50 NGT32 175x75 NGT33 1 100x50 NGT42 1 100x75 NGT43 1 100x100 NGT44 1 150x50 NGT62 1 150x75 NGT63 1 150x100 NGT64 1 150x150 NGT66 1

90° Internal Cover BendPart Std.

Size mm No. Pack

50x50 NGI22 175x50 NGI32 175x75 NGI33 1 100x50 NGI42 1 100x75 NGI43 1 100x100 NGI44 1 150x50 NGI62 1 150x75 NGI63 1 150x100 NGI64 1 150x150 NGI66 1

90° External Cover Bend

Part Std.Size mm No. Pack

50x50 NGE22 175x50 NGE32 175x75 NGE33 1 100x50 NGE42 1 100x75 NGE43 1 100x100 NGE44 1 150x50 NGE62 1 150x75 NGE63 1 150x100 NGE64 1 150x150 NGE66 1

45° Top Cover BendPart Std.

Size mm No. Pack

50x50 FBT22 175x50 FBT32 175x75 FBT33 1 100x50 FBT42 1 100x75 FBT43 1 100x100 FBT44 1 150x50 FBT62 1 150x75 FBT63 1 150x100 FBT64 1 150x150 FBT66 1

ZP

SF

CF

EL

UNIVOLT - CABLE MANAGEMENT SYSTEMS

4 Available from: MARYLAND METRICS http://6mm.com

Part Std.Size mm No. Pack

50x50 FBE22 175x50 FBE32 175x75 FBE33 1 100x50 FBE42 1 100x75 FBE43 1 100x100 FBE44 1 150x50 FBE62 1 150x75 FBE63 1 150x100 FBE64 1 150x150 FBE66 1

45° External Cover Bend

Tee Top CoverPart Std.

Size mm No. Pack

50x50 GTT22 175x50 GTT32 175x75 GTT33 1 100x50 GTT42 1 100x75 GTT43 1 100x100 GTT44 1 150x50 GTT62 1 150x75 GTT63 1 150x100 GTT64 1 150x150 GTT66 1

Tee Internal CoverPart Std.

Size mm No. Pack

50x50 GTI22 175x50 GTI32 175x75 GTI33 1 100x50 GTI42 1 100x75 GTI43 1 100x100 GTI44 1 150x50 GTI62 1 150x75 GTI63 1 150x100 GTI64 1 150x150 GTI66 1

Tee External Cover

Part Std.Size mm No. Pack

50x50 GTE22 175x50 GTE32 175x75 GTE33 1 100x50 GTE42 1 100x75 GTE43 1 100x100 GTE44 1 150x50 GTE62 1 150x75 GTE63 1 150x100 GTE64 1 150x150 GTE66 1

4/way IntersectionPart Std.

Size mm No. Pack

50x50 FGI22 175x50 FGI32 175x75 FGI33 1 100x50 FGI42 1 100x75 FGI43 1 100x100 FGI44 1 150x50 FGI62 1 150x75 FGI63 1 150x100 FGI64 1 150x150 FGI66 1

UNIVOLT - CABLE MANAGEMENT SYSTEMS45° Internal Cover Bend

Part Std.Size mm No. Pack

50x50 FBI22 175x50 FBI32 175x75 FBI33 1 100x50 FBI42 1 100x75 FBI43 1 100x100 FBI44 1 150x50 FBI62 1 150x75 FBI63 1 150x100 FBI64 1 150x150 FBI66 1

5Available from: MARYLAND METRICS http://6mm.com

Part Std.Size mm No. Pack

50x50 FC22 175x50 FC32 175x75 FC33 1 100x50 FC42 1 100x75 FC43 1 100x100 FC44 1 150x50 FC62 1 150x75 FC63 1 150x100 FC64 1 150x150 FC66 1

Flange Outlet

Supplied in Pairs

Pin RackPart Std.

Size mm No. Pack

50x50 PR22 175x50 PR32 175x75 PR33 1 100x50 PR42 1 100x75 PR43 1 100x100 PR44 1 150x50 PR62 1 150x75 PR63 1 150x100 PR64 1 150x150 PR66 1

Reducer

Part Std.Size mm No. Pack

75x50 RD32_ _ 175x75 RD33_ _ 1 100x50 RD42_ _ 1 100x75 RD43_ _ 1 100x100 RD44_ _ 1 150x50 RD62_ _ 1 150x75 RD63_ _ 1 150x100 RD64_ _ 1 150x150 RD66_ _ 1

Cable RetainerPart Std.

Size/width mm No. Pack

50 CRSP2 175 CRSP3 1100 CRSP4 1150 CRSP6 1

Trunking HangerPart Std.

Size mm No. Pack

50x50 SB22 175x50 SB32 175x75 SB33 1 100x50 SB42 1 100x75 SB43 1 100x100 SB44 1 150x50 SB62 1 150x75 SB63 1 150x100 SB64 1 150x150 SB66 1

UNIVOLT - CABLE MANAGEMENT SYSTEMSStop End

Part Std.Size mm No. Pack

50x50 SE22 175x50 SE32 175x75 SE33 1 100x50 SE42 1 100x75 SE43 1 100x100 SE44 1 150x50 SE62 1 150x75 SE63 1 150x100 SE64 1 150x150 SE66 1

To complete the Part No. add the reduced size required ( e.g. 100x100 reducing to 75x75 = RD4433 )

Single Socket Outlet PlateSize mm Part Std.

Type width x length No. Pack

Horiz. 100x200 SOS1 1 Horiz. 150x200 SOS2 1 Vert. 100x200 SOV1 1 Vert. 150x200 SOV2 1

Twin Socket Outlet PlateSize mm Part Std.

Type width x length No. Pack

Horiz. 100x200 SOT1 1 Horiz. 150x200 SOT2 1

Pedestal Box

Finish - Powder Coated White

Part Std.Size No. Pack

Single gang BS1 1 Twin gang BS2 1

For mounting on floors or benches

Vertical Horizontal

6 Available from: MARYLAND METRICS http://6mm.com

STEEL LIGHTING TRUNKINGProduct Info:Supplied in lengths of 3.6 and 5 m. Designed for direct mounting onto a ceiling or from joists and beams in industrial buildings for electrical lighting systems.Specifications: The Trunking is manufactured with a Quality Management System to ISO 9001:2000.Material: Made from hot dipped galvanised sheet / coil steel to BS EN10142:1991 ( Pre-Galvanised) in a rolled-form construction. Finish: Self coloured galvanised Sizes & Fittings: The standard size is 50x50 mm, Wall thickness 1.0 mm

Options available to special order:Polyester Powder Coated - White Colour

STEEL LIGHTING TRUNKING

Size Size Wall WeightLength mm inches Part No. Thickness mm kg/length

3.6 m 50x50 2x2 LTL22/3 1.0 4.45.0 m 50x50 2x2 LTL22/5 1.0 6.0

Steel Lid

Size mm Part No. length

50 LLS 2 m

PVC Lid

Size mm Part No. length

50 LLP 2 m

UNIVOLT - CABLE MANAGEMENT SYSTEMS

7Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMSFlat Intersection

Part Std.Size mm No. Pack

50x50 LF1 1

Flat TeePart Std.

Size mm No. Pack

50x50 LF2 1

90° Internal BendPart Std.

Size mm No. Pack

50x50 LF3 1

90° External BendPart Std.

Size mm No. Pack

50x50 LF4 1

90° Flat BendPart Std.

Size mm No. Pack

50x50 LF5 1

Stop EndPart Std.

Size mm No. Pack

50x50 LF6 1

Cable RetainerPart Std.

Size mm No. Pack

50x50 LF7 1

Long CouplerPart Std.

Size mm No. Pack

50x50 LF8 1

Flange OutletPart Std.

Size mm No. Pack

50x50 LF9 1

Girder ClampPart Std.

Size mm No. Pack

50x50 LF10 1

Supplied with a M10 Hex/HeadSet Screw

Suspension UnitPart Std.

Size mm No. Pack

50x50 LF11 10

for light fittings Supplied with M20 brass bush & locknut

Trunking HangerSize hole Part Std.mm dia. No. Pack

50x50 10mm LF12/1 150x50 20mm LF12/2 1

8 Available from: MARYLAND METRICS http://6mm.com

45° Flat BendPart Std.

Size mm No. Pack

50x50 LF13 1

45° Internal BendPart Std.

Size mm No. Pack

50x50 LF14 1

45° External BendPart Std.

Size mm No. Pack

50x50 LF15 1

STEEL THREADED ROD (BZP)

Part Std.Size No. length

M6 TR1 3mM8 TR2 3mM10 TR3 3mM12 TR4 3m

Connectors for threaded rodPart Std.

Size No. Pack

M6 CO1 1M8 CO2 1M10 CO3 1M12 CO4 1

Standard length 18mm

Fixings for threaded rodPart No. Part No.Hex Flat Std.

Size Nuts Washers Pack

M6 HX1 FW1 200M8 HX2 FW2 200 M10 HX3 FW3 200 M12 HX4 FW4 200

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Suspension HookPart Std. No. Pack

LF16 1

Note: Lids for fittings LF1 - LF5 and LF13 - LF15 are not supplied as standard but to special order.

9Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

STEEL CABLE TRAYProduct Info:Supplied in standard 3 m lengths and in 3 types: Light Duty tray (L/D) is a single flanged perforated tray used for the distribution of light electrical, data and voice services. Medium Return tray (M/R) is a return flanged perforated tray used for the distribution of electrical data and voice services. Heavy Return tray (H/R) is a return flanged perforated tray providing extra strength for large spans or heavy loads. Specifications: The Tray is manufactured with a Quality Management System to ISO 9001:2000.Material: Made from hot dipped galvanised sheet / coil steel to BS EN10142:1991 ( Pre-Galvanised).Finish: Self coloured galvanised Sizes & Fittings: The standard stock sizes are from 50 mm to 600 mm.Light Gauge tray has a connecting method for tray lengths to be joined without couplers. Each length has one end with splayed edges to allow the following length to fit in and fixed with nuts and bolts.

Options available to special order:1) Galvanised after manufacture (post galv. steel to BS EN ISO1461:1999)2) a) Polyester Powder Coated

b) PVC Coated3) Larger sizes - 750 and 900 mm4) Tray Covers

STEEL LIGHT DUTY TRAY (Pre Galv.)

Size mm Wall Weightwidth x flange height Part No. Thickness mm kg/3mt

50 12 LCC2 0.8 1.575 12 LCC3 0.8 1.8100 12 LCC4 0.8 2.4150 12 LCC6 0.8 3.0225 12 LCC9 1.0 5.7300 20 LCC12 1.2 9.0450 20 LCC18 1.5 15.9600 20 LCC24 1.5 19.5

Part Std. Size mm No. Pack

50 NL2 175 NL3 1100 NL4 1150 NL6 1225 NL9 1300 NL12 1450 NL18 1600 NL24 1

L/D - 90° Flat Bend L/D - 90° Internal Bend

Part Std. Size mm No. Pack

50 IL2 175 IL3 1100 IL4 1150 IL6 1225 IL9 1300 IL12 1450 IL18 1600 IL24 1

10 Available from: MARYLAND METRICS http://6mm.com

Part Std.Size mm No. Pack

50 FL2 175 FL3 1100 FL4 1150 FL6 1225 FL9 1300 FL12 1450 FL18 1600 FL24 1

L/D - 45° Flat Bend

L/D - Flat TeePart Std.

Size mm No. Pack

50 TLE2 175 TLE3 1100 TLE4 1150 TLE6 1225 TLE9 1300 TLE12 1450 TLE18 1600 TLE24 1

L/D - 4/way IntersectionPart Std.

Size mm No. Pack

50 WL2 175 WL3 1100 WL4 1150 WL6 1225 WL9 1300 WL12 1450 WL18 1600 WL24 1

L/D - Reducer

Part Std.Size mm No. Pack

75 DL3_ 1100 DL4_ 1150 DL6_ 1225 DL9_ 1300 DL12_ 1450 DL18_ 1600 DL24_ 1

To complete the part no. add the reduced size required where designated (e.g. 150 reducing to 100 = DL64)

UNIVOLT - CABLE MANAGEMENT SYSTEMSL/D - 90° External Bend

Part Std.Size mm No. Pack

50 XL2 175 XL3 1100 XL4 1150 XL6 1225 XL9 1300 XL12 1450 XL18 1600 XL24 1

11Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMSSTEEL MEDIUM RETURN TRAY (Pre Galv.)

Size mm Wall Weightwidth x flange height Part No. Thickness mm kg/3mt

50 25 MDT2 0.9 2.175 25 MDT3 0.9 2.4100 25 MDT4 0.9 3.0150 25 MDT6 0.9 3.9225 25 MDT9 1.0 6.6300 25 MDT12 1.0 9.9450 25 MDT18 1.5 17.4600 25 MDT24 1.5 21.3

Part Std.Size mm No. Pack

50 ND2 175 ND3 1100 ND4 1150 ND6 1225 ND9 1300 ND12 1450 ND18 1600 ND24 1

M/R - 90° Flat Bend

M/R - 90° Internal BendPart Std.

Size mm No. Pack

50 ID2 175 ID3 1100 ID4 1150 ID6 1225 ID9 1300 ID12 1450 ID18 1600 ID24 1

M/R - 90° External Bend

Part Std.Size mm No. Pack

50 XD2 175 XD3 1100 XD4 1150 XD6 1225 XD9 1300 XD12 1450 XD18 1600 XD24 1

M/R - 45° Flat BendPart Std.

Size No. Pack

50 FD2 175 FD3 1100 FD4 1150 FD6 1225 FD9 1300 FD12 1450 FD18 1600 FD24 1

12 Available from: MARYLAND METRICS http://6mm.com

Part Std.Size mm No. Pack

50 WD2 175 WD3 1100 WD4 1150 WD6 1225 WD9 1300 WD12 1450 WD18 1600 WD24 1

M/R - 4/way Intersection

M/R - ReducerPart Std.

Size mm No. Pack

75 DD3_ 1100 DD4_ 1150 DD6_ 1225 DD9_ 1300 DD12_ 1450 DD18_ 1600 DD24_ 1

To complete the part no. add the reduced size required where designated (e.g. 150 reducing to 100 = DD64)

M/R - Coupler

Part Std.Size mm No. Pack

standard SCD1 1

supplied in pairs

UNIVOLT - CABLE MANAGEMENT SYSTEMSM/R - Flat Tee

Part Std.Size mm No. Pack

50 TD2 175 TD3 1100 TD4 1150 TD6 1225 TD9 1300 TD12 1450 TD18 1600 TD24 1

13Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Part Std.Size mm No. Pack

50 NY2 175 NY3 1100 NY4 1150 NY6 1225 NY9 1300 NY12 1450 NY18 1600 NY24 1

H/R - 90° Internal BendPart Std.

Size mm No. Pack

50 IY2 175 IY3 1100 IY4 1150 IY6 1225 IY9 1300 IY12 1450 IY18 1600 IY24 1

H/R - 90° External Bend

Part Std.Size mm No. Pack

50 XY2 175 XY3 1100 XY4 1150 XY6 1225 XY9 1300 XY12 1450 XY18 1600 XY24 1

Part Std.Size No. Pack

50 FY2 175 FY3 1100 FY4 1150 FY6 1225 FY9 1300 FY12 1450 FY18 1600 FY24 1

H/R - Flat TeePart STY.

Size mm No. Pack

50 TY2 175 TY3 1100 TY4 1150 TY6 1225 TY9 1300 TY12 1450 TY18 1600 TY24 1

Part Std.Size mm No. Pack

50 WY2 175 WY3 1100 WY4 1150 WY6 1225 WY9 1300 WY12 1450 WY18 1600 WY24 1

H/R - 4/way Intersection

STEEL HEAVY RETURN TRAY (Pre Galv.)

Size mm Wall Weightwidth x flange height Part No. Thickness mm kg/3mt

50 50 HCT2 0.9 3.375 50 HCT3 0.9 3.6100 50 HCT4 0.9 3.9150 50 HCT6 0.9 5.1225 50 HCT9 1.2 9.3300 50 HCT12 1.2 11.4450 50 HCT18 1.5 18.9600 50 HCT24 1.5 31.2

H/R - 90° Flat Bend H/R - 45° Flat Bend

14 Available from: MARYLAND METRICS http://6mm.com

H/R - Reducer H/R - CouplerUNIVOLT - CABLE MANAGEMENT SYSTEMS

Part Std.Size mm No. Pack

75 DY3_ 1100 DY4_ 1150 DY6_ 1225 DY9_ 1300 DY12_ 1450 DY18_ 1600 DY24_ 1 To complete the part no. add the reduced size required where designated (e.g. 150 reducing to 100 = DY64)

Part Std.Size mm No. Pack

standard SCY1 1

supplied in pairs

STEEL TRAY SUPPORT FITTINGSStand Off Bracket

Size mm Part Std. width x height No. Pack

50x25 SOB2/A 175x25 SOB3/A 1 100x25 SOB4/A 1 150x25 SOB6/A 150x50 SOB2/B 175x50 SOB3/B 1 100x50 SOB4/B 1 150x50 SOB6/B 150x75 SOB2/C 175x75 SOB3/C 1 100x75 SOB4/C 1 150x75 SOB6/C 1

Part Std.Size/width No. Pack

50 CAL2 175 CAL3 1100 CAL4 1150 CAL6 1225 CAL9 1300 CAL12 1

Cantilever Arm / Light Duty

Part Std.Size/width No. Pack

100 OH4 1150 OH6 1225 OH9 1300 OH12 1

Overhead Hook Hanger

Part Std.Size/width No. Pack

100 THL4 1150 THL6 1225 THL9 1300 THL12 1

Trapeze Hanger / Light Duty

Part Std.Size/width No. Pack

150 CAF6 1300 CAF12 1450 CAF18 1600 CAF24 1 2 hole type / post galv. finish

Cantilever Arm / Heavy Duty

Part Std.Size/width No. Pack

300 THH12 1450 THH18 1600 THH24 1

Trapeze Hanger / Heavy Duty

Part Std.Size/width No. Pack

150 FP6 1225 FP9 1300 FP12 1450 FP18 1600 FP24 1

Fish Plate

ALL HEAVY DUTY RETURN TRAY

TO ORDER ONLY

15Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Roofing Nuts & Bolts (BZP)

Part Std.Size mm No. Pack

M6x12 RN1 200 M6x16 RN2 200 M6x20 RN3 200 M6x25 RN4 200 M6x30 RN5 100 M6x40 RN6 100 M6x50 RN7 100

Hex Head Set Screws (BZP)

Part Std.Size mm No. Pack

M6x16 M6x16H 200 M6x20 M6x20H 200 M6x25 M6x25H 200 M6x30 M6x30H 200 M8x20 M8x20H 100 M8x25 M8x25H 100 M8x30 M8x30H 100 M8x35 M8x35H 100 M8x40 M8x40H 100 M8x50 M8x50H 100

Cone Point Screws (BZP)

Part Std.Size mm No. Pack

M10x40 CPS1 100

Hex Nuts (BZP)

Part Std.Size mm No. Pack

M6 HX1 200M8 HX2 200M10 HX3 200M12 HX4 200

Wedge Nuts (BZP)

Penny Washers (BZP)

Lock Washers (BZP)

Shakeproof Washers (BZP)

Eye Bolts (BZP)

STEEL FIXINGS

Part Std.Size mm No. Pack

M6 WN1 100M8 WN2 100M10 WN3 100M12 WN4 100

Part Std.Size mm No. Pack

M6 FW1 200M8 FW2 200M10 FW3 200M12 FW4 200

Flat Washers (BZP)

Part Std.Size mm No. Pack

M6 PW1 200M8 PW2 200M10 PW3 200M12 PW4 200

Part Std.Size mm No. Pack

M6 LW1 200M8 LW2 200M10 LW3 200M12 LW4 200

Part Std.Size mm No. Pack

M6 SW1 200M8 SW2 200M10 SW3 200M12 SW4 200

Part Std.Size mm No. Pack

M6x80 EB1 100 M8x80 EB2 100 M10x80 EB3 100 M12x80 EB4 100

16 Available from: MARYLAND METRICS http://6mm.com

Non Drill Anchors (BZP)

Purlin Clips

Girder Clamps

UNIVOLT - CABLE MANAGEMENT SYSTEMS U-Bolts (BZP)

Part Std.Size mm No. Pack

M8x65 UB1 100 M8x110 UB2 100 M8x150 UB3 100 M10x65 UB4 100 M10x80 UB5 100 M10x110 UB6 100

Part Std.Size mm No. Pack

M6 NDA1 100M8 NDA2 100M10 NDA3 100M12 NDA4 100

Hole dia./ Part Std.Size mm No. Pack

M8 CF57/8 1M10 CF57/10 1M12 CF57/12 1

Hole dia./ Part Std.Size mm No. Pack

M10 GC1 1M12 GC2 1

Notes:

17Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

STEEL CHANNEL SUPPORT

Product Info:Supplied in 3 mt. lengths and in 2 standard sizes and wall thicknesses.Designed for use as a structual support system for fixing pipework, cabling, tray, etc.It is fully adjustable and a large range of fittings is available to provide connections between channels.

Specifications:Available in Plain and Slotted versions. Light Gauge and Heavy Gauge.

Finish Options:a) Hot dipped galvanised to BS EN ISO 1461b) Polyester Powder Coated

Material:Manufactured from pre galvanised mild steel to BS EN10147.

Steel Channel Support

Wall Weighttype size mm Part No. Thickness mm kg/3mt

plain 41x21 DS1 1.5 3.75plain 41x21 DS3 2.5 5.25

plain 41x41 DL1 1.5 5.20plain 41x41 DL3 2.5 7.50

slotted 41x21 TS1 1.5 3.45slotted 41x21 TS3 2.5 4.60

slotted 41x41 TL1 1.5 4.50slotted 41x41 TL3 2.5 6.75

Steel Channel Nuts (BZP)

size mm Part No. Std.Pack

no spring, for 21/41 mm depth M6 NS6 100M8 NS8 100M10 NS10 100M12 NS12 100short spring, for 21 mm depth M6 SS6 100M8 SS8 100M10 SS10 100M12 SS12 100long spring, for 41 mm depth M6 LS6 100M8 LS8 100M10 LS10 100M12 LS12 100

For use with all channels. For maximum load capacity M12 channel nuts should always be used.Standard finish: zinc plated to BS 3382, Part 2

NS

SS

LS

18 Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

STEEL CHANNEL BRACKETS & FITTINGSThe fittings are designed to provide connections between channels to form a rigid, fully adjustable framework support for all building services. The brackets are manufactured to BS 6946 and made from 6mm thick steel.Finish: hot dipped galvanised to BS EN ISO 1416. Standard hole diam.: 14mm, use M12 set screws and channel nuts for fixing.

5 Hole Joint Plate Flat Bend - 3 Hole Flat Tee - 4 Hole 90° Angle Bracket CF14 CF15 CF16 CF17 50x48

90° Angle Bracket 90° Angle Bracket 90° Angle Bracket 90° Angle BracketCF18 50x96 CF19 55x132 CF20 86x102 CF21 91x55

90° Angle Bracket 90° Angle Bracket Tee Bracket - Right Hand Tee Bracket - Left HandCF22 42x57 CF23 42x102 CF24 90° CF25 90°

Tee Bracket 90° Tee Bracket 45° 90° Delta Bracket 90° Delta BracketCF26 CF27 CF28 90x106 CF29 90x57

90° Shelf Bracket Obtuse Angle Bracket Obtuse Angle Bracket Obtuse Angle BracketCF30 CF31 15° CF32 22.5° CF33 45°

available in 6-12mm holes

1 Hole Joint Plate 2 Hole Joint Plate 3 Hole Joint Plate 4 Hole Joint PlateCF10 CF11 CF12 CF13

19Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Acute Angle Bracket Z Bracket 21mm Z Bracket 41mm Z Bracket 87mmCF34 45° CF35 Shallow CF36 Single CF37 Double

Channel Connector U Bracket 41/21 U Bracket 41/41 U Bracket 41/82CF38 Double 96mm CF39 Shallow Top Hat CF40 Single Top Hat CF41 DoubleTop Hat

U Bracket 82/41 Wing Bracket Base Plate - Single Fix Base Plate - Double FixCF42 Double Width T. H. CF43 CF44 CF45

Base Plate - Double Delta Base Plate Delta Base Plate Toe Beam ClampCF46 Double Channel CF47 Single CF48 Double CF49

Edge Beam Clamp End Beam Clamp 'Z' Type Beam Clamp Beam Clamp 41x21CF50 CF51 CF52 CF53 Window Bracket

Beam Clamp 41x41 Beam Clamp Hanger Clamp Purlin ClipCF54 Window Bracket CF55 CF56 6-12mm CF57

Note: No fixings are supplied with the brackets and must be ordered seperately.

Concrete Insert 41x41 / 3 m length CF58 thickness 2.5mm, post galvanised to BS 729

20 Available from: MARYLAND METRICS http://6mm.com

STEEL LIGHTING CHANNEL FITTINGS

Steel Closure Strip Conduit Entry Cap 90° Flat Bend Flat TeeCF64 3m CF65 CF66 CF67

Flat Intersection Ceiling Tile Support Stop End 41x41 Stop End 41x21CF68 CF69 3m CF70 CF71

To attach fluorescent fittings

Adaptor M20 Suspension Bracket Internal Couplers PVC Closure StripCF60 CF61 CF62/2 for 41mm channel CF63 3m

CF 62/4 for 21mm channel

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Notes:

21Available from: MARYLAND METRICS http://6mm.com

STEEL CAVITY FLOOR TRUNKING

Product Info:Supplied in 3 metre lengths and available in 3 or 4 equal compartment options as standard.

Specifications:Each length has 20 mm knockouts down both sides at 1mt intervals and supplied with a cover, all connectors & screws. Standard cover thickness 2.5 mm.

Material:Manufactured from pre galvanised sheet steel to BS EN10142 & 3

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL CAVITY FLOOR TRUNKING

Sizes mm Part No. Sizes mm Part No.

225 x 50 / 3 comp. CVT1 300 x 50 / 4 comp. CVT4300 x 50 / 3 comp. CVT2 450 x 50 / 4 comp. CVT5450 x 50 / 3 comp. CVT3

Standard Fittings

90° Flat Bend Flange Outlet90° Riser Bend ConnectorIntersection Service Outlet Box (3/4 comp.)Flat Tee Stop EndHeader Box Grommets

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Cavity Floor Service Outlet Box

The box is simple to install with the base of the box being clamped from the underside of the tile using an adjuster screw located within the box, eliminating the need for drilling the floor tile. The 3 compartment box can be converted to a 4 comp. box by repositioning the seperators within the base box and then adding the 4 comp. plates.Overall dimensions of the box: 339x244x85 mm. The box has 20 + 25 mm knockouts for flexible conduit entries.The cover is reinforced by a 3mm steel plate & has a carpet recess of 6mm. There are 2 hinged cable outlet flaps and 2 cable retainer grommets within the frame. Material: Base box is manufactured from 1mm pre-galv. sheet steel to BS EN 10142. Trap & frame are manufactured from ABS plastic giving high impact resistance and strength plus being flame retardant.

box type Part No. Std.Pack

3 compartment CSM2 14 compartment CSM3 1

Additional socket outlet plates are ordered seperately, see page 22.

CSM2

CSM3

22 Available from: MARYLAND METRICS http://6mm.com

SERVICE OUTLET PLATES

Product Info:A range of outlet plates are available for both 3 and 4 compartment boxes.The 4 compartment box plates have a reduced width and only a restricted amount of plates are available. The plates are suitable for power, voice and data services and are supplied as standard.

Material:Steel and epoxy coated

Note:Wiring devices are not included

3 compartment Plate Types

Plate width: 97 mm

Plate type Part No. Std.Pack

One Single Socket Outlet Plate SOR1 1

Two Single Sockets Outlet Plate SOR2 1

One Twin Socket Outlet Plate SOR3 1

One Twin Panel Mounted Plate SOR4 1

Blank Plate SOR5 1

RJ45 Plate - 4 hole SOR6 1

25 Pin 'D' Connector x2 SOR7 1

For Cavity Floor Boxes.

4 compartment Plate Types

Plate width: 72.5 mm

Plate type Part No. Std.Pack

One Twin Panel Mounted Plate SOV1 1

Blank Plate SOV2 1

RJ45 Plate - 4 hole SOV3 1

25 Pin 'D' Connector x2 SOV4 1

SOR1

SOR3

SOR5

SOR7

SOR4

SOR2

SOV2

SOV4

SOV1

UNIVOLT - CABLE MANAGEMENT SYSTEMS

23Available from: MARYLAND METRICS http://6mm.com

Product Info:Supplied in 2 metre lengths and available in 2 or 3 equal compartment options as standard.

Specifications:Each 2mt. length is supplied with 2 saddle clamps and all screws.Standard trunking wall thickness 1.0 mm.The trunking should be installed on a ribbon screed above the floor slab to ensure that it is fully supported along the entire length. Recommended minimum screed depth = trunking depth plus nominal 15mm. Recommended minimum screed above trunking ) 30mm.

Material:Manufactured from pre galvanised sheet steel to BS EN10142 & 3

STEEL UNDERFLOOR TRUNKING

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL UNDERFLOOR TRUNKING

Sizes mm Part No. Sizes mm Part No.

150 x 25 / 2 comp. UFT1 150 x 38 / 2 comp. UFT5150 x 25 / 3 comp. UFT2 150 x 38 / 3 comp. UFT6

225 x 25 / 3 comp. UFT3 225 x 38 / 3 comp. UFT7300 x 25 / 3 comp. UFT4 300 x 38 / 3 comp. UFT8

Standard Fittings

90° Flat Bend Stop End90° Riser Bend Service Outlet Box (3/4 comp.)Junction Box Trunking AdaptorSaddle Clamp

Underfloor Service Outlet Box

The box is designed to suit screeded floor depths of between 65-85mm.. For 2 compartment trunking use a 4 compartment service outlet box.

Nominal dimension of box 303x221mm Nominal box depth 60mm with 15mm extra adjustment.

box type Part No. Std.Pack

3 compartment USM1 14 compartment USM2 1

The boxes have 2 standard carpet trim options:a) Moulded ABS/Polycarbonate trim to BS 4800-18 B 25, standard colour greyb) Steel trim - epoxy powder finished zinc coated steel The boxes contain 1x13amp twin switched socket outlet and plate as standard. Additional socket outlets & plates are ordered seperately, see page 26.

For ABS or Steel trim ad 'A' or 'S' after the part no. where required.

UNIVOLT - CABLE MANAGEMENT SYSTEMS

24 Available from: MARYLAND METRICS http://6mm.com

STEEL FLUSH FLOOR TRUNKINGProduct Info:Supplied in 2 metre lengths and available in 3 or 4 equal compartment options as standard.

Specifications:Each 2mt. length of trunking is fitted with 4 x 500 mm length covers and supplied with all connectors and screws. Standard cover thickness 2.5 mm.The service box is supplied fitted into the 500mm length covers and can be fitted at each lid position.The trunking should be installed on a ribbon screed above the floor slab to ensure that it is fully supported along the entire length. Recommended minimum screed depth = trunking depth plus nominal 15mm.

Material:Manufactured from pre galvanised sheet steel to BS EN10142 & 3

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL FLUSH FLOOR TRUNKING

Size mm Part No. Size mm Part No.

330 x 60 / 3 comp. FFT1 330 x 60 / 4 comp. FFT2

Standard Fittings

90° Riser Bend Stop EndConnector Set Service Outlet Box (3/4 comp.)Junction Box Trunking Adaptor

Flush Floor Service Outlet Box

The box is supplied fitted into 500mm long cover which fits into the trunking body. It can be laid in any position along the length of the trunking.

Nominal cut out size of box 305x225mm Nominal box depth 60mm

box type Part No. Std.Pack

3 compartment FSM1 14 compartment FSM2 1

The boxes have 2 standard carpet trim options:a) Moulded ABS/Polycarbonate trim to BS 4800-18 B 25, standard colour greyb) Steel trim - epoxy powder finished zinc coated steel The boxes contain 1x13amp twin switched socket outlet and plate as standard. Additional socket outlets & plates are ordered seperately, see page 26.

For ABS or Steel trim ad 'A' or 'S' after the part no. where required.

UNIVOLT - CABLE MANAGEMENT SYSTEMS

25Available from: MARYLAND METRICS http://6mm.com

STEEL SHALLOW FLUSH FLOOR TRUNKINGProduct Info:Supplied in 2 metre lengths and available in 2 or 3 equal compartment options as standard.

Specifications:Each 2mt. length of trunking is fitted with 4 x 500 mm length covers and supplied with all connectors and screws. Standard cover thickness 2.5 mm.The trunking should be installed on a ribbon screed above the floor slab to ensure that it is fully supported along the entire length. Recommended minimum screed depth = trunking depth plus nominal 15mm.

Material:Manufactured from pre galvanised sheet steel to BS EN10142 & 3

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL SHALLOW FLUSH FLOOR TRUNKING

Sizes mm Part No. Sizes mm Part No.

150 x 25 / 2 comp. SFT1 150 x 38 / 2 comp. SFT4150 x 25 / 3 comp. SFT2 150 x 38 / 3 comp. SFT5

225 x 25 / 3 comp. SFT3 225 x 38 / 3 comp. SFT6

Standard Fittings

90° Riser Bend Stop EndConduit Outlet Plate Service Outlet Box (2/3 comp.)Connector Set Trunking AdaptorJunction Box

Shallow Flush Floor Service Outlet Box

The box is designed for use in screeded floors. For 2 compartment trunking use a 4 compartment service outlet box.

Nominal dimension of box 330x290mm Nominal box depth 60mm

box type Part No. Std.Pack

3 compartment SLM1 14 compartment SLM2 1

The boxes have 2 standard carpet trim options:a) Moulded ABS/Polycarbonate trim to BS 4800-18 B 25, standard colour greyb) Steel trim - epoxy powder finished zinc coated steel The boxes contain 1x13amp twin switched socket outlet and plate as standard. Additional socket outlets & plates are ordered seperately, see page 26.

For ABS or Steel trim ad 'A' or 'S' after the part no. where required.

UNIVOLT - CABLE MANAGEMENT SYSTEMS

26 Available from: MARYLAND METRICS http://6mm.com

SERVICE OUTLET SOCKETS & PLATESFor Flush Floor, Shallow Flush Floor and Underfloor Boxes.Standard size: 3 compartment boxes 4 compartment boxes are made to special order.When ordering 4 comp. boxes the corresponding plates must be ordered as well. Just add the letter 'F' after the part no. where required.

Power Sockets & Plates - for 3 comp. boxes

fitted with power sockets

type Part No. Std. Pack

2x Single Unswitched POS1 12x Single Switched POS2 1Twin Unswitched POS3 1Twin Switched POS4 1

Blank Plates - for 3 comp. boxes

type Part No. Std. Pack

blank POS5 1

Data Outlet Plates - for 3 comp. boxesPart.no. Part no.

type cutout 24x16mm cutout 37x22mm Std. Pack

1 cutout plate DOP1/A DOP1/B 12 cutout plate DOP2/A DOP2/B 13 cutout plate DOP3/A DOP3/B 14 cutout plate DOP4/A DOP4/B 1

Wiring devices are not included.

Single Outlet Plates - for 3 comp. boxes

type Part No. Std. Pack

1 x Single POS6 12 x Single POS7 1

Wiring devices are not included.

Other Plates available to special order:

- BNC Plates- IBM LAN Plates - 25 Pin D Connector Plates

UNIVOLT - CABLE MANAGEMENT SYSTEMS

side wired

Standard 13amp Socket

27Available from: MARYLAND METRICS http://6mm.com

STEEL SKIRTING TRUNKINGProduct Info:Supplied in 2 metre lengths and available in 2 or 3 equal compartment options as standard.

Specifications:Each length is supplied with: Body: coupler & M5 fixing screws

Cover: fixing strap, bridge & M3.5 fixing screws

Options:Finish: a) Standard white powder coated or other colours to special order

b) Zintec

Profiles: a) chamferedb) square

Material:Body manufactured from pre galvanised sheet steel to BS EN10142 & 3.Cover manufactured from zinc coated mild steel to BS EN10152.

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL SKIRTING TRUNKING

Sizes mm Part No. Sizes mm Part No.

150 x 50 / 2 comp. SKT1 200 x 50 / 2 comp. SKT3150 x 50 / 3 comp. SKT2 200 x 50 / 3 comp. SKT4

Standard Fittings

Internal & External Bends Bridge & Strap 90° Flat Riser Bend (L&R) Pier Sets Flat Riser Tee Back BoxInternal Tee (L&R) Cable RetainersStop End (L&R) Socket Plate Spacer Socket Outlet Plates (Single or Twin) Body Coupler Panel Mounted Outlet Plates (Single or Twin)

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Chamfer Square

Compartment Dimensions - mm:

Chamfer: 150x50 / 2 comp. - 50/100Chamfer: 150x50 / 3 comp. - 50/70/30Square: 150x50 / 2 comp. - 50/100Square: 150x50 / 3 comp. - 40/70/40

Chamfer: 200x50 / 2 comp. - 50/150Chamfer: 200x50 / 3 comp. - 50/100/50Square: 200x50 / 2 comp. - 50/150Square: 200x50 / 3 comp. - 50/100/50

If chamfered section is required add letter 'C' after part no., if square add 'S'

28 Available from: MARYLAND METRICS http://6mm.com

STEEL DADO TRUNKINGProduct Info:Supplied in 2 metre lengths and available in 2 or 3 equal compartment options as standard.

Specifications:Each length is supplied with: Body: coupler & M5 fixing screws

Cover: fixing strap, bridge plus M3.5 screws.

Options:Finish: a) Standard white powder coated or other colours to special order

b) Zintec

Profiles: a) chamferedb) square

Material:Body manufactured from pre galvanised sheet steel to BS EN10142 & 3.Cover manufactured from zinc coated mild steel to BS EN10152.

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL DADO TRUNKING

Sizes mm Partno. Sizes mm Part no.

150 x 50 / 2 comp. DDT1 175 x 50 / 3 comp. DDT3150 x 50 / 3 comp. DDT2 200 x 50 / 3 comp. DDT4

Standard Fittings

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Chamfer Square

Compartment Dimensions - mm:

Chamfer: 175x50 / 3 comp. - 50/75/50Chamfer: 200x50 / 3 comp. - 50/100/50

Square: 150x50 / 2 comp. - 50/100Square: 150x50 / 3 comp. - 40/70/40Square: 200x50 / 3 comp. - 50/100/50

If chamfered section is required add letter 'C' after part no., if square add 'S'.

Chamfer not available on size 150x50

Internal & External Bends Flat Riser & Descending Bends (L&R)Flat Tee Internal Tee (L&R)Stop End (L&R)Bridge & Strap Pier Sets Back Box Cable Retainers Socket Outlet Plates (Single or Twin)Panel Mounted Outlet Plates (Single or Twin) Socket Plate Spacer Body Coupler

29Available from: MARYLAND METRICS http://6mm.com

STEEL BENCH TRUNKINGProduct Info:Supplied in 2 metre lengths and available in 1, 2 or 3 compartment options.

Specifications:Each length is supplied with: Body: coupler & fixing screws

Cover: fixing strap, bridge plus M3.5 screws.

Finish Options:a) Standard white powder coated or other colours to special orderb) Zintec

Material:Body manufactured from pre galvanised sheet steel to BS EN10142 & 3.Cover manufactured from zinc coated mild steel to BS EN10152.

All Trunkings & Fittings are available to order only. For quotation: list trunking part no. and fittings required.

STEEL BENCH TRUNKING

Sizes mm Part no. Size mm Part no.

90 x 55 / 1 comp. BHT1 190 x 90 / 3 comp. BHT3140 x 75 / 2 comp. BHT2

Standard Fittings

90° Internal Bend 90° External Bend Stop End (L&R)Bridge & Strap Back Box Socket Plate Spacer Socket Outlet Plates (Single or Twin) Body Coupler

UNIVOLT - CABLE MANAGEMENT SYSTEMS

Compartment Dimensions - mm:

90x55 / 1 comp. - 90140x75 / 2 comp. - 50/90190x90 / 3 comp. - 50/90/50

30 Available from: MARYLAND METRICS http://6mm.com

STEEL WIRE BASKET TRAYProduct Info:The basket tray is simple and quick to install providing the user with a high strength light weight basket tray system with maximum cable ventilation.

Specifications:Standard length: 3 mts, standard depths: 35mm (medium duty) & 60mm (heavy duty), standard width: 60 - 600 mm, wire diameters: 4.4 & 4.9mm The tray fittings such as bends, tees, crossovers & reducers are made on site from standard straight lengths by cutting the wires to size with bolt cutters. Wire mesh: 50x100mm

Material:Manufactured from electro zinc plated steel

Option:Hot dipped galvanised after manufacture to BS EN ISO 1461

Medium Duty Basket Tray / depth 35mm

wire Weightsize mm diameter Part No. kg/3mt

100x35 4.4 WBM1 2.25200x35 4.4 WBM2 3.60300x35 4.4 WBM3 4.50

Heavy Duty Basket Tray / depth 60mm

wire Weightsize mm diameter Part No. kg/3mt

60x60 4.4 WBH1 2.75100x60 4.4 WBH2 3.60150x60 4.4 WBH3 4.20200x60 4.4 WBH4 4.95300x60 4.9 WBH5 6.70400x60 4.9 WBH6 9.75500x60 4.9 WBH7 11.50600x60 4.9 WBH8 16.50

UNIVOLT - CABLE MANAGEMENT SYSTEMS

All Basket Tray and Accessories are available to order only.

31Available from: MARYLAND METRICS http://6mm.com

Bolt CutterPart Std.

Size/length No. Pack

450mm WBF1 1

Reinforced Joint ClampPart Std.No. Pack

WBF2 50 supplied with bolt, nut & plate

Part ClampPart Std.No. Pack

WBF3 50

Connector PlatePart Std. No. Pack

WBF4 50

Splice PlatePart Std.No. Pack

WBF5 10 for producing bends

Central Hanging PlatePart Std.

Size No. Pack

M8 WBF6/A 20M10 WBF6/B 20

Small Universal BracketPart Std.No. Pack

WBF9 10

Ceiling BracketSize/ Part Std. length mm No. Pack

100 WBF10/A 4150 WBF10/B 4200 WBF10/C 4300 WBF10/D 4 Supplied with plastic mounting to aid fitting

Pendant BracketSize/ Part Std. height mm No. Pack

400 WBF11/A 5500 WBF11/B 5600 WBF11/C 5 Supplied with plastic mounting to aid fitting

Side Support PlatePart Std.No. Pack

WBF7 25 required for size 60x60mmClip-on type

Standard BracketSize/ Part Std. length mm No. Pack

100 WBF12/A 5150 WBF12/B 5200 WBF12/C 5300 WBF12/D 5 Supplied with plastic mounting to aid fitting

Universal Mounting BracketPart Std.No. Pack

WBF8/A 10

Stand Off BracketSize/ Part Std. length mm No. Pack

180 WBF13/A 10350 WBF13/B 10

Ceiling SupportPart Std. No. Pack

WBF14 10

Ceiling Rod BracketPart Std.No. Pack

WBF15 10

UNIVOLT - CABLE MANAGEMENT SYSTEMS

32 Available from: MARYLAND METRICS http://6mm.com

UNIVOLT - CABLE MANAGEMENT SYSTEMSGENERAL TERMS AND CONDITIONS FOR SALE AND DELIVERY OF DIETZEL GMBH.

1. General Provisions1.1 These general terms and conditions shall apply unless the parties to the contract have expressly made an explicit agreement to the contrary in writing.1.2 Any quotations submitted by DIETZEL GmbH. (hereinafter briefly referred to as DIETZEL) shall be subject to change without notice. The contract shall only come into force upon written confirmation or delivery. The documents part of

the quotation such as illustrations, drawings, weights and measurements in particular shall only be considered to be approximate statements unless they were expressly referred to as binding. Statements as to properties, weights,volumes, capacities, colours, prices and similar specifications shall only become an integral part of the contract to the extent they were used in the catalogues, circulars, brochures, adverts, illustrations and price lists used by DIETZELin the course of its business operations.

1.3 DIETZEL expressly reserves the right to implement changes in the design and shape of the subject matter of the contract based on technical progress without prior announcement.1.4 Guarantees, collateral agreements and changes in and amendments to this agreement shall only be effective in writing. This requirement cannot be dispensed with.1.5 Changes in the general terms and conditions of sale and delivery shall become legally effective at the beginning of next but one month following the month during which the customer was notified and shall henceforth apply to any

current and future business transactions between the customer and DIETZEL unless a written objection filed by the customer was received by DIETZEL prior to that date.2. Prices and Terms of Payment2.1 Unless otherwise agreed, DIETZEL’s prices shall be ex works or warehouse, excluding loading, excluding VAT. Unless otherwise agreed, we will charge the prices applicable on the day of delivery.2.2 The indicated prices are including packaging as usual in trade. Any other packaging which might be required shall be charged at the actual fee. If reusable packaging which is provided upon delivery is not returned in time franco one

of DIETZEL’s warehouses, it shall be invoiced.2.3 Unless otherwise agreed, invoices shall be payable within thirty days from date of invoice without deductions. If the customer effects payment within fourteen days from date of invoice, DIETZEL shall grant the customer a 2 % cash

discount. No cash discount shall be granted for invoices concerning repair and outwork. The ordering party shall not be entitled to a cash discount if the ordering party is in default of payment obligations to DIETZEL based on any othercontracts.

2.4 At request, the customer shall effect payment in instalments to DIETZEL relative to progress in performance of the contract.2.5 The customer shall not be entitled to offset any counterclaims or warranty claims which are in dispute or have not been declared in a final and absolute judgement. This shall also apply to the assertion of a right of retention by the

customer.3. Delay in Payment3.1 If the customer is in delay with payment of an agreed sum or any other performances, DIETZEL shall have the following rights:

• the right to defer performance of its own obligations until the arrears were paid or any other performances were effected.• the right to implement a reasonable extension of the term of delivery.• the right to charge 8 % interest on arrears from the due date subject to assertion of higher actual damage due to delay in performance.• the right to rescind the contract after a reasonable period of grace has lapsed without results.

3.2 In any case, the customer shall be obliged to compensate DIETZEL for any costs incurred for demands for payment as well as any costs such as creditor protection association and collection agency costs and lawyer’s fees incurredbefore institution of proceedings in particular.

4. Delivery and Performance4.1 The term of delivery which must be expressly agreed shall start upon conclusion of the contract but, in any case, not before receipt of a down-payment which might have been agreed. One condition for DIETZEL respecting the term

of delivery shall in any case be the performance of contractual obligations by the customer.4.2 The term of delivery shall be deemed to have been observed if the subject of delivery was dispatched by DIETZEL to the customer or if notice of readiness for shipment was given to the customer by DIETZEL before expiry of the term

of delivery. The term of delivery shall be prolonged correspondingly if changes or amendments are subsequently requested by the customer. This shall also apply if any impediments were to occur which had not been foreseeable uponexecution to the extent such impediments are proven to influence the completion or delivery of the subject of performance such as, in particular, delays caused by force majeure, industrial strife, strikes, lock-outs, delays in the deliveryof key raw materials, materials or components. This shall also apply if the above-mentioned circumstances occur at one of DIETZEL’s sub-suppliers. If the delivery cannot be effected due to the occurrence of such circumstances,DIETZEL shall be entitled to repudiate the contract. This shall not give rise to any customer claims whatsoever. This shall also apply if the aforementioned circumstances have occurred during an unrelated delay in performance.

4.3 If it is impossible to ship goods ready for shipment without DIETZEL being responsible for this inability to ship or if the customer refuses to take delivery of the goods, DIETZEL shall be entitled to store the goods at the customer’sexpense. In this case, delivery shall be deemed to have been effected upon delivery to the warehouse. This shall, however, be without prejudice to the agreed terms of payment.

5. Passage of Risks5.1 Unless otherwise agreed, the goods shall be deemed to have been sold „ex works“ (readiness for collection). DIETZEL shall effect delivery excluding insurance and duties unpaid ex works. Part deliveries shall be allowed, unless

otherwise agreed.5.2 The risk of accidental perishing of a chattel and damage shall pass to the customer upon dispatch of the delivery parts at the latest even if part deliveries are effected and other items are included in DIETZEL’s scope of performance

such as consignment fees or delivery and installation.5.3 Otherwise, the INCOTERMS as amended on the day of execution of the contract shall apply.6. Reservation of Ownership and Assignment6.1 DIETZEL reserves the proprietary right to the object of purchase until complete performance of all financial obligations by the customer.6.2 The customer shall be entitled to sell the reserved goods in its ordinary course of business as long as it is not in delay with payment. It shall not be entitled to dispose of the reserved goods any other way (such as by chattel mortgage,

assignment by way of pledge). The customer’s claims to payment of the purchasing price or compensation for work arising from resale of the reserved goods shall be assigned to DIETZEL up to the amount of DIETZEL’s claim to thecustomer.

6.3 In case of a delay in payment, the risk of cessation of payments or in the event of execution upon the customer’s assets, DIETZEL shall be entitled to dismantle the reserved goods and/or otherwise require them to be returned. Thisshall not, however, be considered to be a repudiation of the contract. The customer is required to return property.

6.4 DIETZEL must promptly be informed if the reserved goods are assigned by way of pledge or if the reserved goods are affected any other way by third parties. The customer shall bear any costs incurred for such third-party attachment.6.5 The customer expressly consents to DIETZEL’s right to assign any claims to the customer to third parties for any purpose whatsoever. Any prohibition to assign which might be applicable shall only become legally effective if this was

explicitly agreed between the parties to the contract in each specific case.7. Returned Goods7.1 Goods can only be returned if this was expressly agreed in writing beforehand. Goods must be returned franco warehouse specified by DIETZEL. The goods must be as good as new and packed in their original packaging. In any case,

DIETZEL shall charge a reasonable manipulation fee.8. Warranty8.1 DIETZEL shall assume warranty for the accordance of the delivered goods with the order and for the fitness of the goods for normal use.

It is expressly stated that indications as to the properties, weight, volume, capacity, colour, prices and any other specifications shall only become an integral part of the contract if these statements were used in the catalogues, circulars,brochures, adverts, illustrations and price lists used by DIETZEL in its ordinary course of business. Public statements on DIETZEL products by parties other than DIETZEL shall not be decisive for the evaluation of the integral partsof the contract.

8.2 DIETZEL shall only assume a warranty obligation for defects which are based on a design defect, faulty material or execution and even then only if such defects are noticed over a period of twelve months of common use from thepassage of risks and/or the date of delivery:a) Within the first six months, DIETZEL undertakes, at its absolute discretion, to rectify defects or replace parts in defective goods which turn out to be unfit for use or only suitable for considerably limited use due to a circumstance whichoccurred before the passage of risks such as, in particular, faulty construction, faulty material or faulty execution free of charge excluding incidental expenses (such as, in particular, travelling time costs, labour costs or transport costsand the like). DIETZEL reserves title to the replaced components.The customer must prove that the defect already existed at the time of delivery within the first six months after delivery.b) Six months after performance, DIETZEL shall assume a guarantee for, at its absolute discretion, either repairing or replacing defective objects by objects free of defects for another six months if it can be proven that the defectivegoods are not fit for use or are only suitable for considerably limited use due to a manufacturing defect, faulty material or design. Any incidental expenses such as travelling time expenses, labour costs or transport costs in particular,shall be borne by the customer. DIETZEL excludes liability for any other warranty claims such as, in particular, the right of rescission of sale or reduction in price (even in the event of failure of the rectification of defects and/or repeateddelivery) as well as claims for damages on any legal basis whatsoever.

8.3 The customer shall only be entitled to claim relief based on its warranty rights if DIETZEL was promptly notified of the defects which have occurred in writing. In this case, DIETZEL shall have the following options if the defects can berectified by DIETZEL based on the applicable provisions: a) it can rectify defects in defective goods at the customer’s premises; b) it can ask the customer to send the defective goods or components to it for rectifying the defects; c)it can replace the defective goods or components. If it is impossible to rectify the defects or if it would be disproportionately expensive to rectify the defects, DIETZEL shall also be entitled to grant a reasonable reduction in the price.

8.4 If the defective goods or components are returned for rectification of defects or replacement, the customer shall bear both the costs and risk of transportation.8.5 The defective goods or components replaced pursuant to these provisions shall exclusively be placed at DIETZEL’s disposal.

DIETZEL’s warranty obligations shall only apply to defects which have occurred subject to observance of the prescribed operating conditions and in the course of use common in trade. The customer must provide evidence. Inparticular, DIETZEL shall not assume warranty for defects which were caused due to improper installation by the customer or its agents, improper maintenance, improper repair or modifications by third parties which were not approvedby DIETZEL in writing as well as common wear and tear.

8.6 DIETZEL’s liability based on the special right of recourse shall in any case expire two years from DIETZEL’s performance and the scope of liability shall be limited to the effect that the customer is only indemnified for any warranty costswhich might be incurred by the customer to the amount of the actually agreed DIETZEL sales price of the defective goods minus any cash discounts or other discounts which might have been granted.

8.7 DIETZEL shall not assume liability for defects in excess of the aforementioned provisions.9. Liability9.1 DIETZEL shall not assume liability for personal injury, for damage to goods which do not constitute a subject matter of the contract as well as for any other damage and lost profit unless it turns out in this individual case that this was

caused by DIETZEL with gross negligence.9.2 The goods delivered by DIETZEL are safe to the extent specified in the provisions for approval, operating instructions, DIETZEL instructions on how to use the object of purchase such as, in particular, with a view to any inspections

which might be required and other warnings which might have been given. If sub-section 8.1 does not apply, DIETZEL’s liability for slightly negligent damage shall in any case be limited to 5 % of the volume of the order.9.3 Unless otherwise agreed, this stipulation shall exclude liability on the part of DIETZEL vis-à-vis the customer for production downtime, lost profits, loss of use, lost contracts or any other economic or indirect consequential damage.10. Data Protection10.1 DIETZEL shall be entitled to store, transmit, revise or delete personal data concerning the customer in the course of its ordinary business.10.2 The parties undertake to keep any information obtained within the framework of their business relations strictly confidential and refrain from disclosing it to third parties.11. Place of Jurisdiction, Applicable Law, Place of Performance11.1 The court which has jurisdiction as regards the subject matter at the registered office of DIETZEL GmbH. in Vienna shall be the place of jurisdiction for any disputes which might arise directly or indirectly from the contract. Regardless

of this agreement, DIETZEL shall be entitled to invoke a court competent for the other party to the contract.11.2 The remainder of this contract shall continue to be binding even if individual provisions of this contract may be or become legally invalid. This shall not apply if it would constitute an unreasonable hardship for either of the parties to

continue to be bound by the terms of this contract.11.3 This contract shall be governed by Austrian substantive law. Both parties have mutually agreed to exclude application of the United Nations Convention on Contracts for the International Sale of Goods.11.4 The registered office of DIETZEL GmbH. in Vienna shall constitute the place of delivery and place of payment even if it is agreed to effect delivery to any other location.

CONDITIONS OF SALE

OTHER UNIVOLT® CABLE MANAGEMENT PRODUCTSAVAILABLE

For details refer to our Catalogue 1/2002 Section 1 - Plastics

• PVC Minitrunking System• PVC Maxitrunking System• PVC Skirting & Dado Trunking System

(3-compartment trunking)• PVC Rigid Conduit & Fittings• PVC Pliable, Corrugated Conduit & Fittings• PVC Oval Conduit & Channelling• PVC Concrete Installation System

• LSOH HFT Minitrunking System• LSOH HFT Rigid and Pliable Conduit & Fittings• LSOH HFT Nylon Flexible Conduit & Glands• LSOH HFT Supertube - Rigid & Pliable Conduit

(Plastic/Aluminium)

• Metal Steel Conduit & Fittings• Metal Aluminium Conduit & Fittings• Metal Stainless Steel Conduit & Fittings

• PVC Rigid and Pliable Ducting• PE Twin Walled Cable Ducting• PE Pliable Ductings for Optical Fibre Cables

• PE Cable Cover & Protection Plates• PE Plastag Ducting & Bends• PE Underground Warning Tapes

III

Cable Management Systems

®

DIETZEL GmbH1. Haidequerstrasse 3-5 A-1111 Vienna / Austria

DIETZEL UNIVOLT Products are available from:

MARYLAND METRICSP.O. Box 261 Owings Mills, MD 21117 USA phones: (410)358-3130 (800)638-1830 faxes: (410)358-3142 (800)872-9329 email: [email protected] web: http://mdmetric.com