by: mario martinez president pro green roof systems and construction, llc
TRANSCRIPT
Super Therm®
By: Mario Martinez
President
Pro Green Roof Systems and Construction, LLC
What is Super Therm® ?
Super Therm® is a thermal barrier ceramic coatingSuper Therm® is a ceramic based, water borne,
thermal barrier coating that is designed to block and reflect heat that decreases energy and maintenance cost. As the only ceramic coating developed in cooperation with NASA, Super Therm® is the most effective, durable, and long lasting ceramic coating on the market.
What makes Super Therm® unique?
Average Energy Savings
30%
Heat Sources from the SunTypes of heat Infrared
Visible LightUltraviolet
3%
57%40%
How much Infrared, Visible Light, and Ultraviolet heat does Super Therm® block?
Percentage of heat that is blocked by Super Therm®
Infrare
d
99.5%
Visible Light 92%
Ultraviolet 99%
Definitions• Solar Reflectivity - Amount of incoming solar energy a
material reflects (usually in a %)• Emissivity – Amount of energy a material emits due to its
own heat and temperature (usually in %)
Sun
Roof
Reflected Emitted
• Fear of glare• Super Therm® produces diffused reflections, not secular reflections
Roof
Secular
Diffuse
Nippon Paint Factory Roof Insulation
Residential Home in Little Rock, Arkansas
Heat Loss Captured by Infrared Camera AFTER Application of
Super Therm®
Heat Loss Captured by Infrared Camera BEFORE
Application of Super Therm®
Why is Super Therm® preferred over other products?
Super Therm® has a unique ceramic composition
• Blend of four different ceramics that block all windows of heat transfer.
• Other ceramic coatings only contain glass hollow spheres that reflect visual light when clean but absorb and transfer other windows of heat.
• Only ceramic coating rated as an insulator by BOCA (Us Building Code)
• Includes various resins, including urethanes for durability and longevity
Protection from the Elements
Rain Moisture Humidity
Reduces sound waves by 68%
Super Therm™
68% reduction
Super Therm® is rated as a true insulator by BOCA (US Building Code)
R19 equivalent rating
10 mils dry
Super Therm™ 6” – 8”
ASHRAE 90.1 Code ComplianceTESTING REQUIRED TO PROVE THE “R” VALUE
A. ASTM C 236-89 “ Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box.”
B. ASTM 1269 “Differential Scanning Calorimeter”
ASTM E 1461-92 “Thermal Diffusivity.”
Super Therm® has a “U” ( Thermal Flow) Value of 0.052.
Super Therm® is (1/RE) = 0.052 Thermal Flow. ASHRAE 90.1 Compliance Varrience cannot exceed 0.061 for Thermal Flow.
Super Therm® falls within the ASHRAE 90.1 Compliance Rating and is acceptable.
Super Therm® has a Class A Fire Rating
Super Therm™
Super Therm® prevents mold and mildew
Super Therm® is USDA Approved
Super Therm® is a certified water barrier(ASTM D 7088, ASTM D 6904)
Super Therm™
Super Therm® is Environmentally friendly(24 grams of VOC)
Super Therm® has a very long life expectancy
Super Therm® has extraordinary e l a s t i c i t y
Passed ASTM E1737
Super Therm™
Where can Super Therm® be used?
Roof Insulation
Concrete Insulation
Walls Floors
Sound Proofing
Vending Machines Elevator Shafts
Air Conditioning & Ducting
AC Units AC Ducting
Companies that have used Super Therm®
Customers who have used Super Therm®
Nissan Motor Co. Ltd.Yokahama, Japan
200,000 sq. Meters
Before After
Chicago Bridge & Iron CompanyBeaumont, TexasBefore Super
Therm® Application Saw Tooth
Section Built 1937
After Super
Therm® Applicatio
n
187,000 Sq.Ft. of Metal and 82,000 Sq.Ft. of Tar & Gravel
Tucson International AirportSuper Therm® was applied toCentral PlantWest ConcourseEast ConcourseWash Bays
Note:A power wash and thorough
cleaning was performed on all roof tops prior to application
Tucson International Airport
August 2009 Savings = $22,144
Chris Wilt - Senior Director Facility Development
Circle K in Tucson (before Super Therm®)
Circle K in Tucson (after Super Therm®)
TRUMP INTERNATIONAL FT. LAUDERDALE, FL
Super Therm® was applied toConcrete ceiling of lobbyConcrete ceiling of parking
structure under air conditioned space
SANTA ROSA DUNES PENSACOLA, FL
Bel-Air Condos in Austin, TexasSPI iStucco™ System
Thermal Scan BEFORE iStucco™ System
Thermal Scan AFTER iStucco ™ System
iStucco System BEFORE
Ceramic iStucco Application
iStucco After Super Therm®
Frito Lay Trailer, KY Trailer
Irvington Elementary School, KY
Apartent Buildings And HotelIn Munich Germany
Residential HomeLas Vegas, Nevada
Testing, Certification and Endorsements of Super Therm
ENERGY STAR Program
Approved and accepted with Energy Star for energy savingsASTM E 903-96 Reflectivity = 80%Only 1% reduction in reflectivity over 3 years (3% over 10 years
ASTM TestingB 117/D 1654 450 Hour Salt Spray (Fog) – PassedC 177 thermal conductivity testing – PassedC 236 (C236-89(1993)el) – Passed, our performed
fiberglass by 148%.Standard Test Method for Steady-State Thermal
Performance of Building Assemblies by means of Guarded Hot Box. Testing for measuring R-values.
C 411 High – Temperature Surface Performance – PassedD 412 Tensile strength – Passed
.041 thickness = 13,248 psi
ASTM Testing Continued…..D 522 – Passed
Resistance to cracking on metal or rubber type materials. 1” (25mm)bend. ¼”(96mm)bend
D 1653 Water Vapor Permeability – PassedD 1654 Salt spray (fog/weathering) – Passed – 2000 hoursD 3273-82T D 3274 – Passed
Resistance to fungal growth or soil and dirt accumulation on paint film. Excellent (8 out of 9)
D 4060 Abrasion Resistance – PassedE 84 Flame Spread / Smoke Developed – Passed
Class “A” Rating (or Class “1” or Class “I”)
ASTM Testing Continued…..
E84-89a Flame spread / Smoke Developed – Passed – “0” developmentFlame Index “0”. Smoke Index “0”
E96 water vapor transmission – Passed – less than .01E 96 water vapor transmission – Passed – less than .01E 903-96 Reflectance – PassedE 119 Structural Steel Fire curve – Passed – 25 minutesE 1269 Thermal penetration through a substrate by differential
scanning calorimeter – Passed – blocking 99% of heat BTU conduction – TPRL
ASTM Testing Continued…..E 1461-92 Laser flash technique conductivity
diffusivity – PassedVTEC Laboratories review of test results – Letter
stating RE19TPRL lab test results show a bare metal plate
allowing 367.20 BTU heat conduction. SUPER THERM® coated on metal plate allowed only 3.99 BTU heat gain. A 99% reduction in heat transfer after applying only one coat of SUPER THERM ® on test plate.
G53 exposure to UV, elevated temperature and humidity - Passed
ICC Approval (International Code Council) 0104
Passed – ID #21-25Council that formally consolidates approvals for BOCA (Building Officials Code Administrators)
Section 723.2 Exposed installations, Thermal insulation
Section 723.3 Concealed installations, Thermal insulation
Section 803.2 Classification, Interior finish1998 International Mechanical Code
Section 604.3 Coverings and Linings, Insulation
ICBO (International Conference of Building Officials)
Passed ASTM E 84 For Flame SpreadPassed ASTM C 411 for High Temperature for
Surface PerformancePassed ASTM C 177 for Thermal Conductivity
(*SUPER THERM Specific)
NASA Testing
NHB 8060.1B/C Test 1 Flammability testing – Passed
“0” Burn, Class “A” rating – PassedNHB 8060.1C, Test 7 Toxic Off gassing –
Passed“K” no Toxic off gassing – Passed“K” Rating for toxicity – PassedTests performed at Marshall Space Flight
Center
Key EndorsementsUSDAPassed
Environmentally safe and safe for use around animalsApproved for incidental food contactLetter of Written Certification as Accepted by USDA from
Manufacturer
Underwriters Laboratory Inc. Approved
Factory Mutual Approval Passed - E - 108 Flame Spread over pitched roofing Tested and Approved for Roofing and all other Applications
California Cool Roof Program California Building Energy Efficiency Standards
Florida Cool Roof Rebate Program State approval for energy rebate