bucky stand/table scale: 1/70 unit: mm...the vertical bucky stand as well. sid tracking the x-ray...
TRANSCRIPT
Akihabara UDX, 4-14-1, Soto-Kanda, Chiyoda-ku, Tokyo, 101-0021, JapanInternational Division PHONE: 81-3-3526-8316 Home page address: CX-E171
http://www.hitachi-medical.co.jp/english
Hitachi Medical Corporation(Head Office, Kashiwa, Osaka and Mobara works), is certified as complying with the International Environmental Management System (ISO 14001).
● Specifications and appearance of the product are subject to change due to improvement.● Be sure to read the Instruction manual of the product for your proper operation.● Radnext is a registered trademark or trademark of Hitachi Medical Corporation in Japan and other countries.
235
790
2,000
1,121 700
790
2,000
1,026 700
64
05
50
2,000
650 600
550
574 (400)(516st)
510
170
180
0
68
0
152
0(
Tota
l he
igh
t o
f th
e s
up
po
rt c
olu
mn)
Bucky stand/table Scale: 1/70Unit: mm
AS-MK1 Vertical bucky standWeight:100kg
AS-MD1 Elevating floating bucky tableWeight:210kg
AS-MB1 Floating bucky tableWeight:120kg
AS-MA1 fixed bucky tableWeight: 50kg
600(Small base)
1,1
20
(Ve
rtic
al s
tro
ke)
1,1
20
(Up
/dow
n s
tro
ke)
±500: Tabletop right/left movement ±430: Tabletop right/left movement
Detector movement range (right/left)±100
Detector movement range(raight/left)±180
35
0~
90
0:
Tabl
eto
p h
eig
ht
55
0:
Tabl
eto
p h
eig
ht
±75: Tabletop fore/back movement ±75:
Tabletop fore/back movement
General Radiography System
1 2
◎Combination of a high-precision and high-performance 50kW inverter type X-ray high voltage generator
◎X-ray high voltage generator with an easy-to-see large LCD color touch panel
◎Design your system to fit your work environment; choose from our wide product lineup
General Radiography System
New Style, Smooth Control.To give your patients the very best care and to give you a little more peace of mind
when performing daily examinations...
Our aim was to create a more comfortable examination environment for you to meet the
daily and diverse needs of your patients; so we provide general radiography for care of
patient, along with highly accurate examination.
We listened to a wide range of on-the-spot views, and conducted a careful analysis of
the key points. We are confident that our new one-hand grip controller provides easy
operation, and it will certainly improve the workflow of whole examinations.
Hope you enjoy more comfortable and easier examination environment with our new
features.
3
Cost-effective digital angle indicatorSmart set with newly-developed one hand grip controller, in addition to the traditional outer frame handle.Single-handed movements and settings of the X-ray tubes.
Easy-to-see color LCD touch panelAdvanced smart set with an easy-to-see color LCD panel.Check and change radiographic parameters and regions in the examination room.
Motorized collimator in standard configurationA hand-operated Motorized collimator allows manual-like light operation. The collimator size can be selected from the LCD display according to the image size. A bucky center indication laser is also equipped for easier center alignment.
I Smart set smooth single-handed operation
I Advanced smart set (optional) Checking/changing of parameters, in addition to single-handed operation
Height trackingThe height of the X-ray tube assembly automatically follows the vertical movement of the vertical bucky stand.* Optional for Smart set.
Additional options need to be added to
the vertical bucky stand as well.
SID trackingThe X-ray tube assembly automatically follows the vertical movement of the bucky table and enables the SID to be fixed.
* Optional for Smart set.
Vertical strokeNow covering a wide area of 1650mm and with 150mm of extended stroke, the system flexibly meets the requirements of many different examinations.
Rotating mechanism around the supporting columnSince the supporting column can be electromagnetically locked at any desired position, angle-setting for lateral direction is very easy.
4
One-hand grip controller is located at a lower position than the outer frame handle, and allows easy single-handed positioning even at those higher positions that are hard to operate only with outer frame handle.
Using the outer frame handle that is easy to hold even at lower positions or the one-hand grip controller that allows you to change directions freely according to the desired position, you can perform various positioning easily without stressful posture.
By using outer frame handle or one-hand grip controller, smooth movement of the X-ray tube in any direction is possible.
Even when the X-ray tube is located horizontally, the one- hand grip controller operates in a natural way.
Our newly-developed one-hand grip controller enables easy singlehand operation.
Effi cient operation with gentle patient careEquipped not just with the traditional outer frame handle, but also
with the newly-developed one-hand grip controller. After in-depth on-
site research, we developed this new freely-rotating one-hand grip
allowing you to make settings in any position or direction that you
select and also ensure smooth X-ray tube movement.
Smoother operation combining the new outer frame handle with our one-hand grip controllerAssigning your most popular functions to the grip switch improves
operability, and the new outer frame handle and one-hand grip
controller combination, ensures a more comfortable workflow.
Functions / strokes
Line UP
Positioning / movements
A wide variety of functions improve the workflow.
Flexible PositioningSmooth Motion Smooth longitudinal movement
* Stand for control console:Optional
5 6
Light weight and compact designChoose the best system mounting method for your clinic layout; flexible design for a low ceiling height or narrow X-ray room.
Easy positioningSmooth and quick manual control of tube support movements: back and forth, lateral and vertical movements.
* A control console for X-ray tube assembly support is added when incorporating the optional electromagnetic off-lock system.
* Universal Bucky stand YUB-1 (variable SID optional)
Ceiling - floor mounted type
Floor mounted type
Multi-purpose buckyNo more stressful positioning: simply use the bucky stand or table when you start.
Upright chest radiographyFor upright chest radiography just set the SID to 2m.
I Universal set A single unit can accommodate an upright position and recumbent position.
I Compact set Cost-effective and simple confi guration
Electromagnetic off-lock mechanism (Optional)For rapid positioning by switch operation, simply incorporate into the mechanism.
Auto tracking mechanism (Optional)To improve your chest radiography workflow, an auto-tracking mechanism, the same as the ceiling-traveling type is available with the compact floor-support type stand.
Electromagnetic off-lock mechanismThis mechanism allows easy positioning.
An example of layout Scale:1/100Unit:mmCompact set
3500
2500
2300
3000
An example of layout Scale:1/100Unit:mmUniversal set
Anatomical programAll at the touch of a button...with an anatomical system, up to 960 programs and easy touch panel registration, selecting X-ray radiographic parameters has never been easier.
Sequence programRegister plural radiographic parameters for each patient as a sequence program, and read out with one-touch operation.
Imaging
Combination of a high-precision and a high-performance inverter type X-ray high voltage generator has realized accurate control and multiple functions. An easy-to-use, operator-friendly X-ray high voltage generator.
Interface
A light and easy-to-see large LCD color touch panel is adopted in the control console.Not only X-ray parameters settings, but also region setting by anatomical program can be easily made within the touch panel operation. In addition, radiographic parameters can be set online from other connected imaging systems such as CR. (optional)
Design
The needs for X-ray examinations are versatile, and required functions are different depending on each institution and examination room. To respond to these various needs, Hitachi makes a wide variety of product lineup available.
Automatic exposure detectorHI-AUTO (photo-timer) or an ion chamber can be connected. The adopted digital-control tube voltage compensation and subject body thickness compensation allows obtaining a stable density. (optional)
Smooth operation with large LCD color touch panel.A console with an easy-to-see large LCD color touch panel.The large LCD touch panel for more inntutive and accurate operation.
Setting of radiography conditionBy connecting with imaging systems such as CR and FPD, radiographic parameters can be set online (Optional).
Inverter X-ray high voltage generator
*The NDD method is a method proposed by The Exposure Reduction Committee of IbarakiAssociation of Radiologic Technologists (Chairman: Mr. Takehiko Mori), its coefficientswere introduced and software was developed by Mr. Itsuki Sato of Ibaraki PrefecturalUniversity of Medical Science.
Exposure dose controlExposure dose is controlled quantitatively by the NDD method, and fluoroscopic and radiographic exposure doses are calculated and displayed. An area dosimeter can be connected optionally.
A foldable bucky table is also included.
87
System configuration
General Radiography System Radnext 50 : Optional: Standard configuration
(Note 1) Standard is marked with a ○ ; however, feel free to choose and combine components marked with a △ .
(Note) For details on the electric equipment such as the recommendable capacity of a distribution transformer, contact our sales representative.
Advancedsmart set
Compactset
Universalset
Components Contents Smart set
Specification of the X-ray high voltage generator for Radnext50
DHF-155H4
SX-A300 standard
SX-A300 with LCD
FS-20A
FS-20B
FS-20C
FS-20D
YUB-1
UH-6PC-31E
UH-6FC-31E
UH-6GE-31E
U-6CE-55TB
U-6AC-31TL
285kJ(400kHU)0.6/1.2mm 12°
210kJ(300kHU)0.6/1.2mm 12°
140kJ(200kHU)0.6/1.2mm 17°
100kJ(140kHU)1.0/2.0mm 17°
210kJ(300kHU)0.6/1.2mm 12°
Motorized collimator
Manual collimator
Nominal max. power
Short-time rating
Technique selection
Tube voltage/Tube current
Timer
Anatomical program
Sequence program
Number of connectable X-ray
tubes
X-ray tube control
Self-diagnostic function
50kW
80kV・630mA/100kV・500mA/150kV・320mA
Max. 8 types
40~150kV (1kV step)/10~800mA (20 or 39 steps)
1ms~8s (79 steps)
120 types for each technique (Max. 960 types)
Max. 120 types × Max. 12 stages
With the high voltage switcher (optional) combined, up to two tubes
can be controlled.
CPU always monitors permissible load data corresponding to
selected X-ray tube assembly and radiographic parameters.
CPU measures irradiation mAs to calculate and control residual
anode heat capacity of each X-ray tube connected.
Provided with protective and failure diagnosis functions by CPU
Radnext50
Power requirements
200/220/240±10% 380/415/440/480±10%
Options
Control stand
Ion chamber: up to 3 sheets connectable (3 fields/1 sheet)
HI-AUTO: up to 4 ch connectable
50/60Hz
Radnext50
3 φ 200V series
200/220/240±10%
1 φ 200V series 3 φ 400V series
Rated supply voltage
Rated supply frequency
X-ray high voltage generator
X-ray tube support
50kW invertor
Ceiling traveling type
(SID variable, optional)Universal type
Floor-mount type
X-ray tube assembly(Note 1)
X-ray variable collimator
Automatic exposure detector
CR/RIS connection, function to connect the area dose meter
Wall/floor-mount type
Wall/floor traveling type
Ceiling/floor traveling type
Floor trabeling type
Built-in full-size FPDThe FPD can be set and used on an upright bucky stand / bucky table (floating type). Any microscopic affected region can be clearly visualized by high-definition FPD with a 139μm pixel size. The wide exposure area, approximately 43cm x 43cm, is ideal for the larger patient, and chest and pelvis examinations.
Selecting the scintillator best suited to your needs
We provide a cost-effective model, and a cesium iodide (Csl) scintillator model (built-in full sized FPD only) for lower dose X-rays.
An example usage on the vertical bucky stand
An example usage on the floating bucky table
An example usage with the FPD removed
Multipurpose cassette-sized FPDA truly versatile FPD; it can be mounted, simply placed on the examination table, or held by the patient.
+ FPDpanel
Digitalradiography
(Note)
AS-MK1 Vertical bucky stand AS-MA1 fixed bucky table AS-MB1 Floating bucky table AS-MD1 Elevating floating bucky table
Hitachi also provides support for system digitization.Drawing upon our years of experience, we will configure the system best suited to your needs, including FPD, any equipment to be combined and image processing.
Evolving into a digital radiography system by combining with FPD.
Many different upright bucky stands and bucky tables are available for you to choose to best suit your use and examination room layout.
Variation A wide variety of equipment to suit your needs and clinic layout (Optional).
(Note) FPD and digital radiography units are optional.
* The cassette FPD can be combined with the existing upright bucky stand/bucky table.For more information about combining the FPD with the existing upright bucky stand/bucky table, contact our sales representative.
109
X-ray tube support unit Scale: 1/70Unit: mm
X-ray high voltage generator
35086
155.5
CN
240
X-ray control unit Weight: Approx. 215kg(Depends on system configuration.)
Control console with stand(Optional) Weight: 14kg
Control console Weight: 5kg
700 480
320 360
1068
Stroke250
2230
700
720
220
Ceiling-suspended type for the smart set/advanced smart set (SX-A300)
Weight:365kg(standard)~490kg(Max)
Wall-floor mounted type for the Compact set (FS-20B)
Weight: 130kg (excluding X-ray tube assembly, X-ray variable collimator.)
Universal Bucky stand YUB-1 (SID variable, optional)
Weight: 290kg (excluding X-ray tube assembly, variable collimator, supporting fork,
high voltage cable.)
1,120 Note 1 1,108 Note 1
2,000
600
825
1,156
(520 Note 2)
400~
1,53
0
594
330
264
Note 1: When SID is 2m Note 2: When SID is 1m
980 Note 11,020 Note 1
(480 Note 2)
12
287
Rotationcenter
Foculspot
442
249
movement range 299 to 3375(In case of standard length: 3950)
(In case of standard length: 2000)movement range 257 to 1543
Focal spot(+90°rotation)
External ceiling rail 3950 (min. 1000 to max. 6000)
Inte
rna
l mov
abl
e r
ail
20
00
(min
. 10
00
to m
ax.
40
00
)
12
1800
86
0 to
25
10F
oca
l sp
ot
mov
em
en
t ra
ng
efo
r d
ecu
bitu
s ra
dio
gra
phy
84
8 to
24
98
Fo
cal s
po
t m
ove
me
nt
ran
ge
for
up
rig
ht
rad
iogr
ap
hy
Turningradius
1,800: Wall rail 250Ceiling surface
Floor level2,200: Floor rail
Str
oke
1,2
00
Wa
ll su
rfa
ce
20
or
mo
re
Scale: 1/70unit: mm
Scale: 1/70unit: mm
Scale: 1/20unit: mm
Specification of the ceiling suspended X-ray tube support unit for Radnext50
7 segments display
Manual collimator
LCD touch-panel
Motorized collimator
3075mm (For standard rail: 3950mm) (Electromagnetic off-lock system)
1285mm (For standard rail: 2000mm) (Electromagnetic off-lock system)
±180°/ Click stop at every 45° (Electromagnetic off-lock system)
±180°/ Click stop at every 90° (Electromagnetic off-lock system)
-
Option
○
○
Smart set (standard)
Advanced smart set (with LCD)
1650mm (Note 1)
2800mm
Height (Upright position)
SID (Recumbent)
(Note 1) 1,600mm when the auto-tracking function is activated.
Control area display
X-ray collimator
Vertical stroke
Longitudinal stroke
Transverse stroke
Rotation around the support arm
Rotation around the support column
Specifications of the floor mounted type X-ray tube support unit for Radnext50
1200mm
250mm
○
1500mm
Manual fixing type
Compact set
Standard
Wall/floor traveling
FS-20B
2230mm
1500mm
Wall/floor-mount type
FS-20A
2150mm
−
Option
Ceiling/floor traveling
FS-20C
2230mm
Floor traveling
FS-20D
2180m
Type
Unit model number
Overall height of support column
X-ray tube vertical stroke
X-ray tube lateral stroke
X-ray tube back and forth (arm) stroke
Locking methodElectromagnetic
Electromagnetic-off-lock
Auto-tracking function (Height direction only)
Option
○(Up/down, Right/left, Fore/back)
○(Up/down ,Fore/back)
○(Up/down, Right/left, Fore/back)
○(Up/down, Right/left, Fore/back)
Auto-tracking function
Programmable brake system function
Recommendable standard ceiling height
Auto collimation function
The ceiling suspended X-ray tube support unit SX-A300 is compact and easy to operate in the examination room.A stand-alone X-ray high voltage generator requires less installation space, leaving a more spacious examination room.
An example of a system confi guration for a ceiling suspended X-ray tube support unit (Smart set)