elegant & economical digital x-ray system · floor-mounted tube stand tabletop vertical bucky...

6
Technology ISS Dynamic Visualization Wireless Rotating Detector Tray Fujifilm DR Solution FDR Clinica Series of Components

Upload: others

Post on 27-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

TechnologyISS Dynamic

VisualizationWireless Rotating

Detector Tray

Elegant & Economical Digital X-Ray system

Fujifilm DR SolutionFDR Clinica Series of Components

Page 2: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

When your focus is on reducing dose and obtaining excellent image quality, FDR D-EVO is for you.

Clinical Confidence

Precision

Patented ISS capture technology promotes high sensitivityThe FDR Clinica Series of Components is intended for use with FDR D-EVO detectors featuring Fujifilm’s proprietary Irradiated Side Sampling (ISS) technology, which positions its capture electronics (TFTs) at the irradiation side, in contrast to traditional detectors. This design significantly suppresses scattering and attenuation of X-ray signals, improving efficiency to produce sharper images at lower doses compared to traditional designs.* ISS system reading technology

X-ray

Scintillationlayer

TFT detector

Optical signal imagereaching TFT detector

Optical signal imagereaching TFT detector

X-ray

TFT detector

Scintillationlayer

Conventional method

Fujifilm is proud to announce our latest

high-quality, cost-effective x-ray solution.

The FDR Clinica Series of Components

deliver a user-friendly, smart workflow

for busy imaging professionals.

*Based on higher MTF and DQE demonstrated in Sato K, et al., Effect of X-ray incident direction and scintillator layer design on image quality of indirect conversion flat-panel detector with GOS phosphor.

Page 3: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

Optimal Efficiency

The FDR Clinica Series of Components has all the

advanced features you need to enhance workflow and

improve the patient experience.

Page 4: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

Both top- and center-reference rotation are available in our rotating tray, with automatic connection to the detector. The detector can be rotated while mounted in the tray with no need to remove and remount, greatly reducing handling.

A wide variety of exams can be performed using the optional tilting wall stand. Nonambulatory patients can be easily imaged in the seated position.

Tilting Wall Stand

Dual-reference Rotation

1

2

The detector cable and connector are built into the tray, enabling the detectors to be automatically connected when set in the tray. This new function greatly improves efficiency and provides a clean look with no need to manage cabling. The automatic connection to the detector keeps the battery charged in the event that wireless operation is required.

Automatic Connection3

New features improve workflow and patient experience.

Fujifilm’s renowned digital image processing expertise, including Dynamic Visualization, optimizes image display based on recognition of contrast levels throughout the entire exposure field. The resulting first-up images have outstanding detail and greater window and leveling capability in PACS.

Advanced image processing: Dynamic Visualization

Conventional image Customized imageNew image

Utility

Page 5: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

The FDR Clinica Series of Components provide flexibility, with a wide selection of power ratings to meet your requirements.

FDR Clinica Series of Components Specifications

Continued on the following page.

X-RAY GENERATOR

FDR Clinica GXR Series of Components

X-RAY TUBE

COLLIMATOR

Output Rating

Product Name

Line Nominal, Phase

Line Voltage Range

kV Range

mA Range

Timer Range

mAs Range

Max. Power Output

Minimum Breaker Rating

Anatomical Programs

Technique Selection

Focal Spot Size

Max. Anode HU

Target Angle

0.6/1.5 mm

200 kHU

14°

0.6/1.2 mm

300 kHU

12°

Field Shape

Max. Field Size

Inherent Filtration

Luminosity

Light Source

Standard

Rectangular

More than 17x 17 in at 100cm SID

Min. 2.0 mmAl eq.

Over 160 LUX at 100 cm SID (Typ. 250 LUX)

Single LED

Laser line, Tape measure, Rotating flange

230VAC, 1110/120VAC, 400VAC, 480VAC, 3

±10 % (Frequency: 50/60 Hz)

40–150 kV, 1 kV step

0.001 to 10 sec, 38 steps

0.1 to 500 mAs

User-programmable max. 1,280 programs with APR utility software

4 point display (kV, mA, Time, mAs)

Line-power TypeCapacitor Type

10 to 500 mA

500mA@80kV400mA@100kV320mA@125kV

15A (230VAC, 1 )

230VAC, 1400VAC, 480VAC, 3

10 to 500 mA

500mA@80kV400mA@100kV320mA@125kV

100A (230VAC, 1 )65A (400VAC, 3 )50A (480VAC, 3 )

10 to 640 mA

640mA@81kV500m A@104kV400mA@130kV320mA@150kV

75A (400VAC, 3 )65A (480VAC, 3 )30A (110VAC, 3 )

10 to 800 mA

800mA@85kV640mA@106kV500mA@136kV400mA@150kV

90A (400VAC, 3 )75A (480VAC, 3 )

40 kW 40 kW 52 kW 68 kW

GXR-C40 GXR-40 GXR-52 GXR-68

Cap

acito

r

HOSPITAL

Outpatient Center

Line Powered GeneratorCapacitor Assisted GeneratorPerfect for the medium-sized x-ray department.

No power supply modification necessary. 40kW Single Phase Input power 3kW.

Can handle the rigorous workload of a large facility with Three Phase Input power and several power ratings from which to choose: 40, 52, or 68 kW.

Hospital

Versatility

Page 6: Elegant & Economical Digital X-Ray system · Floor-mounted Tube Stand Tabletop Vertical Bucky Movement Tabletop Bucky Type/Grid Lock (Brake) Center Indication Dimension/Weight Longitudinal

FUJIFILM Medical Systems U.S.A., Inc. 419 West Avenue, Stamford, CT 06902-6348www.fujimed.com866-879-0006©2016 FUJIFILM Medical Systems USA, Inc. XBUSDR112

(DR-ID 600, including DR-ID 300CL)FDR D-EVO G35i and C35i are available for the FDR Clinica Series of Components. For details, please refer to the FDR D-EVO Series brochures.

Specifications are subject to change without notice.

DimensionsUnit in.(mm)

Patient Table

Minimum Room Layout

6-way Elevating Table

Floor-mounted Tube Stand

Tabletop

Vertical

Bucky

Movement

Tabletop

Bucky Type/Grid

Lock (Brake)

Center Indication

Dimension/Weight

Longitudinal

Transversal

Travel

Speed

Operating

Longitudinal

Inherent Filtration

Max. Patient Weight

Size

Fixed

39 (±20) in

10 (±5) in

14 in with standard tray

1.2 mmAl at 100kV

660 Ibs (300 kg )

FD 100 cm, 103 lpi, ratio 10:1

Cassette Stroke

Bucky Type/Grid

Lock (Brake)

Balance

Dimension/Weight

Fixed

Vertical 65 in (17-81 in from floor to Bucky center)

FD 150 cm, 103 lpi, ratio 10:1EM Lock, Switch on/off

Counter Weight

Max. 85 (H) x 26 (W) x 16 (D) in / 264 lbs (120 kg)

Tube Stroke

Lock (Brake)

Balance

Column Rotation

Dimension/Weight

Longitudinal

Lateral

Vertical

±135°

Max. 87 in

7 in

62 in (17-80 in from floor to focus)

EM Lock, Foot Switch on/off

Counter Weight

90° step

91 (H) x 54 (D) x 118 (W) in / 529 lbs (240 kg)

11 (22-33) in

17 mm/sec

Motorized movement by footswitch DC-motor (Linear Actuator)

87 (W) x 32 (D) x 2 (H) in

EM Lock, Foot Switch on/off

87 (W) x 30 (D) x 2 (H) in

EM Lock, beam sensor on/off Buzzer sound and LED Transverse center, height center

87 (W) x 30 (D) x 26 (H) in 330 lbs (150 kg)

87 (W) x 32 (D) x 33 (H) in573 lbs (260 kg)

4-way Floating Tabletop

Vertical Wall Stand

Min

imum

Cei

ling

Hei

ght:

97 (2

,450

)

Min

imum

31

(800

)

20 (5

10)

23 (580)

20 (5

00)

87 (2

,200

)6 (150)

18 (460) 7 (190)

118 (3000) 24 (600)

20 (5

00)

30 (750)5 (125)

Distribution Panel

Generator

119

(301

0)

177

(450

0)

FDR D-EVO C35i

FDR D-EVO G35i

Continued from the previous page.

Tube Rotation Angle

DR-ID 600

FDR D-EVO for Digital Radiography