btl shortwave al mazroui

2
BTL-6000 SHORTWAVE A NEW GENERATION IN SHORTWAVE DIATHERMY TECHNOLOGY All rights reserved. Although every care has been taken to provide accurate and up-to-date information, no responsibility can be accepted for any mistakes or misprints contained in this catalogue. The products and their specifications, as shown in this catalogue, may change without notice. [email protected] www.btlnet.com BTL-6000 SHORTWAVE 400 BTL-6000 SHORTWAVE 200 User-interface Colour 5.7“ touch-screen Colour 5.7“ touch-screen Inductive / Capacitive 1 or 2 channels inductive 1 channel capacitive 1 or 2 channels inductive Power 400W Pulse 200W Continuous 200W Pulse 100W Continuous Optional Accessories Inductive Applicators 80mm 140mm 80mm 140mm Capacitive Applicators 42mm 85mm 130mm Soft-rubber Plate Applicator 12 x 18cm BTLdiathermy_CAT_EN201 PROVEN THERAPY LATEST TECHNOLOGY Preset Protocols BTL encyclopaedia 62 indications BTL encyclopaedia 62 indications User Programmes 100 user-defined programmes 100 user-defined programmes Pulse Frequency 50 – 1500Hz 50 – 1500Hz Pulse Length 50 – 2000µs 50 – 2000µs

Upload: arshad-nazar

Post on 20-Apr-2015

117 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Btl Shortwave Al Mazroui

BTL-6000 ShorTwave

A New GeNerAtioN iN ShortwAve DiAthermy teChNoLoGy

all rights reserved. although every care has been taken to provide accurate and up-to-date information, no responsibility can be accepted for any mistakes or misprints contained in this catalogue. The products and their specifications, as shown in this catalogue, may change without notice.

[email protected]

BTL-6000 ShorTwave 400 BTL-6000 ShorTwave 200

User-interface Colour 5.7“ touch-screen Colour 5.7“ touch-screen

inductive / Capacitive 1 or 2 channels inductive1 channel capacitive

1 or 2 channels inductive

Power 400w Pulse200w Continuous

200w Pulse100w Continuous

optional accessories

inductive Applicators 80mm140mm

80mm140mm

Capacitive Applicators 42mm85mm130mm

Soft-rubber Plate Applicator 12 x 18cm

BT

Ldia

ther

my_

CA

T_E

N2

01

ProveN TheraPY LaTeST TeChNoLoGY

Preset Protocols BtL encyclopaedia62 indications

BtL encyclopaedia62 indications

User Programmes 100 user-defined programmes 100 user-defined programmes

Pulse Frequency 50 – 1500hz 50 – 1500hz

Pulse Length 50 – 2000µs 50 – 2000µs

Page 2: Btl Shortwave Al Mazroui

Sh

or

Tw

av

e D

iaT

he

rm

Y

the BtL-6000 Shortwave is a state-of-the-art device for high-frequency heat therapy.

the use of high-frequency energy for heat therapy has the advantage of a greater penetration depth in contrast with conventional methods, such as hot packs, baths, infrared light or even microwave treatment.

the heating effect of the electrodes for the inductive and capacitive methods of application is fundamentally different.

CaPaCiTive aPPLiCaTorS

with the capacitive field method, the body part being treated is located in the high-frequency electric field between two insulated electrodes. During the capacitive method of application, the transformation of energy into heat takes place mainly in the tissues with low blood circulation (e.g. fat layer and connective tissues). therefore, the greater part of the heat is generated in areas near the skin’s surface (upper-skin fat tissue). this, combined with the distance between applicator and skin, is important in the patient’s sensation of heat.

iNDUCTive aPPLiCaTorS

the inductive field method produces high-frequency electric currents within the body tissue by means of induction. these currents will increase as the electric conductivity of the corresponding tissue region, such as tissues with good blood circulation (e.g. muscle tissue and inner organs), increases.

FieLDS oF aPPLiCaTioN rehabilitation orthopaedics Neurology Sport medicine Dermatology (wounds, burns and scars) Gynaecology eNt internal medicine Urology

moST CommoN iNDiCaTioNS

TeChNoLoGY BTL-6000 ShorTwave

intuitive operation via the touch-screen

eaSY To STarT

Pre-set therapy protocols User-defined protocols Patient database in the unit encyclopaedia with applicator placement images

maXimaL Power & SaFeTYDue to the advanced automatic tuning system and patient safety-switch

Two DiFFereNT moDeLS:

BTL-6000 ShorTwave 400 For iNDUCtive AND CAPACitive APPLiCAtioNS

Power up to 400w for optimal application possibilities (200w continual)

one channel capacitive field one or two channels inductive field Colour touch-screen user-interface

BTL-6000 ShorTwave 200 For iNDUCtive APPLiCAtioNS

one or two channels inductive field Continuous and pulsed mode Colour touch-screen user-interface

Power up to 200w (100w continual)

FreeDom oF movemeNT

SiX JoiNTeD armS For aLL TreaTmeNT PoSiTioNS From achillodynia to migraine

eaSY aPPLiCaTor SwaPPiNG Click in place, no screwing required

FULLY aDJUSTaBLe 360° rotation in 2 joints