Deepwater Horizon

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 4/26

 Agenda

• What is a BOP/BOP Stack

• Safety Functions for a BOP Stack and Safety Integrity Levels (SIL)

• Critical components in BOP control systems and their reliability

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 5/26

What is a BOP?

•  A blowout preventer

(BOP) is a large,

specialized valve used to

seal, and control oil and gas

wells.

•  A BOP Stack (Well control

package) is the assembly of

well-control equipment

including preventers,

spools, valves, and nipples

connected to the top of the

wellhead.

• Topside/Subsea BOP stacks

Fig: A typical BOP Stack

Drill pipeAnnulus

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 6/26

 A BOP Stack consists of multiple components…

•  According to NORSOK D-001 "Drilling Facilities", paragraph 5.10.3, a BOP shall as a

minimum consist of the following:

 – One (1) annular preventer 

 – One (1) shear ram preventer 

 – Two (2) pipe ram preventers – Minimum one (1) Choke Line outlet

 – Minimum one (1) Kill Line outlet

 – One (1) Wellhead coupling or connector 

 – Minimum two manual gate valves

 – Minimum two remote operated gate valves.

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 7/26

BOP Stacks

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 8/26

Preventer valves

 Annular Preventer Pipe Ram Shear Ram

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 9/26

How does a Ram valve work?

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 10/26

Safety functions of a BOP Stack

• Prevention of blowouts and well leaks

• OLF Guideline 070, defines the following functions for the BOP:

1. Seal around drill pipe

2. Seal an open hole

3. Shear drill pipe and seal off well.

• Thus the guideline differentiates between two main functionalities and set SIL levels

for:

• The annular preventer/pipe ram function (function 1)

• The shear ram function (function 2 & 3 combined).

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 11/26

No valves closed

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 12/26

Seal around Drill pipe

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 13/26

Shear drill pipe and seal off well

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 14/26

Setting A SIL Level for the BOP Safety Functions

• The BOP’s are used for a number of drilling related safety functions

 – Well intervention

 – Drilling

•  A SIL level is only set for the drilling BOP

• Based on data from a Scandpower report “Blowout and Well Release Frequencies”, it

is estimated that the industry is operating with a “blowout prevention reliability”

somewhere close to SIL 3 on average.

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 15/26

Setting a SIL Level for the BOP Safety Functions

• The OLF- guideline discussion concludes with the following:

• “Setting a SIL 3 level to either function would lead to a significant increase in the

standard for drilling BOPs. The challenge lies mainly in the need for documentation of

the system reliability, Setting a SIL 3 level would most certainly also result in the need

for changing the existing control system. It would also be necessary to include

additional RAMs in standard BOP assemblies.”

• The required PFD/SIL for the BOP function for each specific well should be calculated

and a tolerable risk level set as part of the process applying for consent of exploration

and development of the wells. As a minim um the SIL for isolat ion u sing the

annulus fun ct ion sh ould be SIL 2 and the minimum SIL for closing th e

blind/shear RAM should be SIL 2.” 

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 16/26

There are MANY components in the BOP control system!

• Shuttle valves

• Hydraulic Reservoir 

• Filter 

• Check valves

•  Accumulator bottles

• Bleed valves

• Flow Totalisers

• Push-to-hold button

• Indicator lights

• Hydraulic pumps

• Pipe Ram valves

• Hydraulic Block valves

• Pressure gauges• Drillers Panel

• Pressure transmitter 

• Wedge locks

• Gate valves

• Kill & Choke valves

• Shear Ram valve

• Flow transmitter 

• Pilot valve

• Pneumatic Block valve

• Pressure regulator 

• Hydraulic booster pump

• Pushbuttons

• SEM

• PCL

•  Analogue input/output

• SCM

•  Acoustic Transmitter 

• Isolation valves

• Flow transmitter 

• Solenoids

• Umbilical

• Tool pushers panel

• SPM valves

• Pressure Indicators

• Etc.

• Etc.

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 17/26

Components in BOP & control system

• How to decide which components are critical, and which are for information

only, or not critical? – FMECA with client, including operators/drillers

 – SIL Workshops with client, including operators/drillers

 –  Accumulator bottles shall store hydraulic pressure to necessary volume and

pressure to enable closing-opening-closing operation of all rams +25% of volumefor one closing operation of each ram - function independent of many failures in

the hydraulic system

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 18/26

Build Reliability Block Diagrams

OLF Guideline 070 used to determine which functions of the BOP that

shall be SIL rated

Initiator(s) Logic

SIL 2 = 100 %

35 %

PFD < 0.0035

15 %

PFD < 0.0015

 A BFinal

Element(s)

50 %

PFD < 0.0050

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 19/26

Reliability Block Diagram example topside BOP

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 20/26

Reliability Block Diagram example subsea BOP

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 21/26

Challenges

•  All the SIFs for the BOP are manually initiated - Human Factors??

• Difficult to find relevant reliability data

 – Generic data

 – Data from vendors

• Redundancy?

• Not always possible to use pipe rams or shear the drill pipe!

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 22/26

Not possible to Shear/close pipe ram

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 23/26

Remaining issues/Questions

• When is it possible to move the drillpipe up/down if pipe ram/shearram cannot close?

• Everything is manually initiated - Impact of Human Factor?

• The testing of the Shear ram does not include actual cutting of thepipe. I.e the main function is not really tested – Test independentfailures

• Should other BOP functions have a SIL rating?

• Is all critical components identified and included in the SIL function?

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 24/26

Should other BOP functions have a SIL rating?

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 25/26

References

• OLF Guideline 070

• NORSOK D-001

• NORSOK D-010

• Sintef Memo: ”Barriers to prevent and Limit Pollutants to sea”

• Sintef Memo: ”Drill, not Spill”

• Transocean Deepwater Horizon Investigation report chp. 3.4

• BP Deepwater Horizon Investigation report

• Sintef Report ”Reliability of Subsea BOP systems for Deepwater

application, Phase IIDW”

8/10/2019 BOP Basic Safety Functions

http://slidepdf.com/reader/full/bop-basic-safety-functions 26/26

For more information, please contact:

Katrine Harsem Lund

Principal Engineer, Department Manager at Kjeller Office

Scandpower AS

T +47 98 66 08 11

E [email protected]

W www.scandpower.com

w www.lr.org