The main goal of this part is to perform general maintenance activities. Both
teams will perform the required tasks.
1. Before loading new SU/AU SW files, verify that no more than two
SU/AU SW files exist in the NPU/ BST. If there are three SU/AU SW
files in the unit, one of them must be deleted before loading a new
SU/AU SW file.
2. Perform the upgrade, use a DOS TFTP utility with the following syntax:
tftp i hostaddress put sourcefile
3. Verify that download is successfully completed (a transfer successful
DOS message is received), and check that the loaded version exists in
the unit.
PC1 192.168.2.111 255.255.255.0 192.168.2.254 Second IP 192.168.254.250
PC2 192.168.2.112 255.255.255.0 192.168.2.254 Second IP 192.168.254.249
NPU Data Port 192.168.2.250
***Air Link Will be simulated using Coax cables and attenuators
Switch
GPS Antenna
GPS Adapter
AAA & Iperf Server 192.168.2.110
PC3 192.168.2.113 255.255.255.0 192.168.2.254 Second IP 192.168.254.248
PC4 192.168.2.114 255.255.255.0 192.168.2.254 Second IP 192.168.254.247
SU 1A
SU 2A
SU 1B
SU 2B
-
Hands On Assignments SW Upgrade & Backup
BreezeMAX
3
3
3
4. Perform SU SW upgrade using 3 upgrade methods:
a. Per SU.
b. Per AU (for every SU under a specific AU)
c. General SU.
5. Perform AU SW upgrade using 2 upgrade methods:
a. Per AU.
b. General AU.
6. Set the new version as the main version in each one of the upgraded
units.
7. Check that all the units are reset, that the main version is the new
version and the previous version is the shadow version.
8. Build a backup file containing the NPU configuration and upload it to a