  • Hands On Assignments SW Upgrade & Backup

    BreezeMAX

    2

    2

    2

    Figure 1: Topology

    SW Upgrade & Backup

    The main goal of this part is to perform general maintenance activities. Both

    teams will perform the required tasks.

    1. Before loading new SU/AU SW files, verify that no more than two

    SU/AU SW files exist in the NPU/ BST. If there are three SU/AU SW

    files in the unit, one of them must be deleted before loading a new

    SU/AU SW file.

    2. Perform the upgrade, use a DOS TFTP utility with the following syntax:

    tftp i hostaddress put sourcefile

    3. Verify that download is successfully completed (a transfer successful

    DOS message is received), and check that the loaded version exists in

    the unit.

    PC1 192.168.2.111 255.255.255.0 192.168.2.254 Second IP 192.168.254.250

    PC2 192.168.2.112 255.255.255.0 192.168.2.254 Second IP 192.168.254.249

    NPU Data Port 192.168.2.250

    ***Air Link Will be simulated using Coax cables and attenuators

    Switch

    GPS Antenna

    GPS Adapter

    AAA & Iperf Server 192.168.2.110

    PC3 192.168.2.113 255.255.255.0 192.168.2.254 Second IP 192.168.254.248

    PC4 192.168.2.114 255.255.255.0 192.168.2.254 Second IP 192.168.254.247

    SU 1A

    SU 2A

    SU 1B

    SU 2B

  • Hands On Assignments SW Upgrade & Backup

    BreezeMAX

    3

    3

    3

    4. Perform SU SW upgrade using 3 upgrade methods:

    a. Per SU.

    b. Per AU (for every SU under a specific AU)

    c. General SU.

    5. Perform AU SW upgrade using 2 upgrade methods:

    a. Per AU.

    b. General AU.

    6. Set the new version as the main version in each one of the upgraded

    units.

    7. Check that all the units are reset, that the main version is the new

    version and the previous version is the shadow version.

    8. Build a backup file containing the NPU configuration and upload it to a

    PC.