12222 Merit Drive, Suite 1140 Dallas, Texas 75251 Telephone: 972/427-1222 ADDENDUM NO. 03 April 9, 2019 To Drawings and Specifications dated March 8, 2018 Birdville ISD Plaza Renovations BIRDVILLE INDEPENDENT SCHOOL DISTRICT RFCSP #059-19 Prepared by: PBK/IN2 12222 Merit Drive, Suite 1140 Dallas, Texas 75251 Notice to Bidders: A. Receipt of this Addendum shall be acknowledged on the Proposal Form. B. This Addendum forms part of the Contract documents for the above referenced project and shall be incorporated integrally therewith. C. Each proposer shall make necessary adjustments and submit his proposal with full knowledge of all modifications, clarifications, and supplemental data included therein. Where provisions of the following supplemental data differ from those of the original Contract Documents, this Addendum shall govern. QUESTIONS: Item No. 1 Section 10 01 00 Miscellaneous Specialties a) Question: Section calls for storage cabinets, however, they are on the drawings. How many and where located? Answer: No storage cabinets are needed. b) Question: Section calls for manual projection screen with the number, size and location to be on drawings – Electrical drawings show power above ceilings for projection screens. Are they to be manual or powered? Answer: Powered; refer to revised section issued in this Addendum. Item No. 2 Question: Reflective ceiling plans and floor plans show locations of projections screen but do not indicate size. Answer: Refer to Item 9 for revised Section 10 01 00 Miscellaneous Specialties for sizes. Item No. 3 Question: Interior elevations indicates what may be screens with Note 07 however there is references on Note 07. Answer: Refer to Item 12 for revised Sheet A6.22 Item No. 4 Question: Section 21 22 00 – Clean Agent Fire Extinguishing Systems – section does not mention a new pre-action system to be added along with clean agent system, will this be required?. Answer: No, a pre-action system is not required. Item No. 5 Question: What is base bid scope for existing roof? Replace or leave as is? Answer: Leave as is. Item No. 6 Question: Documents for PLC do not indicate existing 2 nd floor, what work is to be done here? Answer: No work on 2 nd floor. 04/09/2019 Addendum 03 - Page 1 of 33

Upload: others

Post on 11-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

12222 Merit Drive, Suite 1140 Dallas, Texas 75251 Telephone: 972/427-1222

ADDENDUM NO. 03

April 9, 2019

To Drawings and Specifications dated March 8, 2018

Birdville ISD Plaza Renovations

BIRDVILLE INDEPENDENT SCHOOL DISTRICT

RFCSP #059-19 Prepared by: PBK/IN2 12222 Merit Drive, Suite 1140 Dallas, Texas 75251 Notice to Bidders: A. Receipt of this Addendum shall be acknowledged on the Proposal Form. B. This Addendum forms part of the Contract documents for the above referenced project and shall be

incorporated integrally therewith. C. Each proposer shall make necessary adjustments and submit his proposal with full knowledge of all

modifications, clarifications, and supplemental data included therein. Where provisions of the following supplemental data differ from those of the original Contract Documents, this Addendum shall govern.

QUESTIONS: Item No. 1 Section 10 01 00 Miscellaneous Specialties

a) Question: Section calls for storage cabinets, however, they are on the drawings. How many and where located?

Answer: No storage cabinets are needed.

b) Question: Section calls for manual projection screen with the number, size and location to be on drawings – Electrical drawings show power above ceilings for projection screens. Are they to be manual or powered?

Answer: Powered; refer to revised section issued in this Addendum.

Item No. 2 Question: Reflective ceiling plans and floor plans show locations of projections screen but do not indicate size.

Answer: Refer to Item 9 for revised Section 10 01 00 Miscellaneous Specialties for sizes.

Item No. 3 Question: Interior elevations indicates what may be screens with Note 07 however there is references on Note 07.

Answer: Refer to Item 12 for revised Sheet A6.22

Item No. 4 Question: Section 21 22 00 – Clean Agent Fire Extinguishing Systems – section does not mention a new pre-action system to be added along with clean agent system, will this be required?.

Answer: No, a pre-action system is not required. Item No. 5 Question: What is base bid scope for existing roof? Replace or leave as is?

Answer: Leave as is. Item No. 6 Question: Documents for PLC do not indicate existing 2nd floor, what work is to be done here?

Answer: No work on 2nd floor.

04/09/2019 

Addendum 03 - Page 1 of 33

Page 2: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

Item No. 7 Question: Section 08 41 13 – Aluminum Framed Entrances and Storefronts; if Alternate 01 is not

accepted, please provide detail for the infill for exterior doors that are being removed as part of base bid?

Answer: Add those doors in base bid. SPECIFICATIONS: Item No. 8 Table of Contents – Revise Table of Contents as follows:

a) Add the following item to Division 1 – 01 31 29 Notification of Architect Requirements b) Add the following item to Division 09 – 09 51 00 Acoustical Ceiling Panels c) Add the following item to Division 10 – 10 56 13 Metal Storage Shelving d) Add the following item to Division 10 – 10 56 26 Mobile High Density Storage e) Delete the following from Division 10 – 10 56 29 Storage Racks f) Add the following item to Division 11 – 11 31 00 Light Commercial Appliances

Item No. 9 Section 01 31 29 – Notification of Architect Requirements: Insert this section in its entirety

Item No. 10 Section 09 51 00 Acoustical Ceiling Panels: Insert this section in its entirety

Item No. 11 Section 10 56 13 Metal Storage Shelving: Insert this section in its entirety

Item No. 12 Section 10 01 00 – Miscellaneous Specialties: Replace this section in its entirety Item No. 13 Section 10 56 26 Mobile High Density Storage: Replace this section in its entirety

Item No. 14 Section 11 31 00 – Light Commercial Appliances: Insert this section in its entirety

DRAWINGS:

Item No. 15 PLC Sheet A6.22 – Interior Elevations: Replace this sheet in its entirety.

Item No. 16 PLC Sheet A8.02 – Casework Elevations/Details: Replace this sheet in its entirety.

Item No. 17 PLC Sheet A10.00 – Composite RCP: Replace this sheet in its entirety.

Item No. 18 PLC Sheet A10.01 – Enlarged RCP: Replace this sheet in its entirety.

Item No. 19 PLC Sheet A10.02 – Ceiling Detail: Replace this sheet in its entirety.

Item No. 20 PLC Sheet E0.02 – Lighting Fixture Schedule: Replace this sheet in its entirety.

Item No. 21 Technology Sheet A2.04 – 1st Floor Area B: Replace this sheet in its entirety.

Item No. 22 Technology Sheet A8.02 – Casework Elevations & Details: Replace this sheet in its entirety.

Item No. 23 Technology Sheet E0.02 – Lighting Fixture Schedule: Replace this sheet in its entirety.

END OF ADDENDUM

Addendum 03 - Page 2 of 33

Page 3: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville independent School District

NOTIFICATION OF ARCHITECT REQUIREMENTS 01 31 29-1

SECTION 01 31 29 - NOTIFICATION OF ARCHITECT REQUIREMENTS CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 REQUIREMENTS

A. In general, the Contractor shall notify the Architect whenever there is need of clarification

of interpretation of the Contract Documents. B. The Contractor shall notify the Architect 48 hours in advance of certain stages of

construction. The project superintendent shall notify the Owner’s Representative on an ongoing basis of ongoing work. These stages shall include, but are not necessarily be limited to the following: 1. Clearing of site. 2. Stripping of top soil within limits of grading. 3. (Excavation and) Placing (of each lift of) select fill material. 4. Compaction, inspection, testing, and covering of underground utilities. 5. Drilled and reamed foundation piers. 6. Excavation of grade beams. 7. Placing of concrete. 8. Concealment of insulation. 9. Installation of firestopping and firesafing. 10. Modified Bitumen Membrane Roofing System 11. Metal Roofing 12. Installation of building and glazing sealants. 13. Installation of glazing and glazed systems. 14. Installation of gypsum wallboard. 15. Installation of ceramic tile. 16. Installation of glazed tile pavers. 17. Installation of acoustical ceiling (grid and panels). 18. Installation of resilient flooring and base. 19. Installation of carpeting. 20. Painting and staining (each coat). 21. Abatement work 22. Installation of heating, ventilating and air conditioning system. 23. HVAC system startup 24. Installation of plumbing fixtures. 25. Any and all testing and training specified for equipment, mechanical, electrical

and plumbing systems. 26. Completion of roughing-in of plumbing, heating, air conditioning and electrical

work (prior to concealment). 27. Initiation of permanent power 28. Installation of all electrical fixtures. 29. Notify Architect and Owner: All pre-construction or trade startup meetings. 30. Owner shall be given notification/opportunity to conduct inspections prior to wall

or ceiling cover up.

C. In addition to notifying the Architect, the Contractor shall also notify the Structural Engineer (48 hours) prior to the following stages: 1. Drilling, reinforcing, and placing of first piers and footings. 2. Placing first reinforcing and grade beams. 3. Erecting structural steel elements.

Addendum 03 - Page 3 of 33

Page 4: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville independent School District

NOTIFICATION OF ARCHITECT REQUIREMENTS 01 31 29-2

D. Above ceiling inspections shall be completed prior to cover up. All systems are to be reviewed at the same inspection. All systems shall be 100 percent complete prior to inspection.

PART 2 - PRODUCTS Not Used PART 3 - EXECUTION 3.1 PRE-CONSTRUCTION CONFERENCE A. The Contractor shall contact Architect at least ten (10) days prior to commencing

construction in order for Architect to schedule a pre-construction and/or trade startups meeting with Contractor, Architect, Owner, and third-party firms. This meeting must occur prior to commencement of any construction.

3.2 CONFERENCES AND MEETINGS

A. Refer to Section 01 31 19, Project Meetings for requirements pertaining to Pre-construction Conference, Progress Meetings, and Pre-installation Conferences.

END OF SECTION

Addendum 03 - Page 4 of 33

Page 5: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 1

SECTION 09 51 00 - ACOUSTICAL CEILING PANELS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes: Requirements including but not limited to: 1. Acoustical panels. 2. Concealed and exposed suspension systems for ceilings. 3. Ceiling panel for food service area. 4. Wood finish acoustical ceiling. 5. Accessories necessary for a complete installation.

1.3 SUBMITTALS

A. Product Data: Technical data for each product including installation instructions.

B. Samples: 1. Acoustic Panel: Set of 6 inch (150 mm) square samples of each type, color, pattern, and

texture. 2. Exposed Suspension System Members, Moldings, and Trim: Set of 12 inch (300 mm) long

samples of each type, finish, and color.

C. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved: 1. Suspended ceiling components. 2. Structural members to which suspension systems will be attached. 3. Size and location of initial access modules for acoustical panels. 4. Items penetrating finished ceiling including but not limited to the following:

a. Lighting fixtures. b. Air outlets and inlets. c. Speakers. d. Sprinklers. e. Access panels.

5. Perimeter moldings.

D. Maintenance Data: Manufacturer data for finishes for inclusion in maintenance manuals.

1.4 QUALITY ASSURANCE

A. Regulatory Requirements: 1. Building Code: Comply with applicable requirements of the IBC for interior finishes. 2. Acoustical Panel Standard: ASTM E 1264 and designated by type, form, pattern, acoustical

rating, and light reflectance. a. Mounting Method for Measuring NRC: Plenum mounting in which face of test

specimen is 15-3/4 inches (400 mm) away from test surface according to ASTM E 795.

Addendum 03 - Page 5 of 33

Page 6: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 2

3. Surface Burning Characteristics: Ceiling panels with surface burning characteristics complying with IBC Chapter 8 and ASTM E 1264 for Class A materials determined by testing identical products in accordance with ASTM E 84: a. Flame Spread Index : 25 or less b. Smoke Developed Index: 450 or less.

4. Seismic Performance: Acoustical ceiling shall withstand the effects of earthquake motions

determined according to ASCE/SEI 7.

B. Source Limitations: 1. Acoustical Ceiling Panel: Obtain each type through one source from a single manufacturer. 2. Suspension System: Obtain each type through one source from a single manufacturer.

C. Comply with applicable regulations regarding toxic and hazardous materials. 1. Coating Based Antimicrobial Treatment: Provide acoustical panels with face and back

surfaces coated with antimicrobial treatment; and showing no mold or mildew growth when tested in accordance with ASTM D3273.

2. Panel Based Antimicrobial Treatment: Provide acoustical panels manufactured with antimicrobial treatment in the panels.

D. Preinstallation Conference: Conduct conference at site.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed, conditioned space protected against damage from moisture, humidity, temperature extremes, direct sunlight, surface contamination, and other causes.

B. Before installing acoustical panels, allow panels to attain room temperature and a stabilized moisture content.

C. Handle acoustical panels carefully to avoid chipping edges or damaging units in any way.

1.6 PROJECT CONDITIONS

A. Environmental Limitations: Do not install acoustical panel ceilings until spaces are enclosed and weatherproof, wet work in spaces is complete and dry, work above ceilings is complete, and ambient temperature and humidity conditions are maintained at the levels indicated for Project when occupied for its intended use. 1. Pressurized Plenums: Operate ventilation system for not less than 48 hours before

beginning acoustical panel ceiling installation.

1.7 WARRANTY

A. Standard Ceiling Panels: Warrant ceiling panels to be free from sagging, warping, shrinking, buckling, or delaminating as a result of manufacturing defects for a period of one (1) year from the date of Substantial Completion.

B. Sag Resistant Ceiling Panels: warrant products to be free from sagging, warping, shrinking,

buckling, or delaminating as a result of manufacturing defects for a period of ten (10) years from the date of Substantial Completion.

Addendum 03 - Page 6 of 33

Page 7: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 3

C. Standard Suspension System: Suspension systems shall be warranted to be free from defects in material or factory workmanship and shall not incur 50 percent red rust as defined by ASTM B117 test procedures for a period of ten (10) years from the date of Substantial Completion.

D. Suspension system / ceiling panels: Provide manufacturers standard 15 year warranty for suspension systems when used in combination with same manufacturers sag resistant ceiling panels. Ceiling panels to be free from sagging, warping, shrinking, buckling, or delaminating as a result of manufacturing defects. Suspension systems shall not incur 50 percent red rust as defined by ASTM b117 test during the period of the warranty, extra materials.

1.8 EXTRA STOCK

A. Furnish extra materials matching products installed and packaged with protective covering for storage and identified with labels describing contents. 1. Acoustical Ceiling Panels: Full size panels equal to 1 percent of quality installed or 2 full

unopened containers, whichever is greater. 2. Suspension System Components: Quantity of each exposed component equal to 2

percent of quantity installed. 3. Hold Down Clips: Equal to 2 percent of quantity installed. 4. Impact Clips: Equal to 2 percent of quantity installed.

PART 2 - PRODUCTS

2.1 MATERIALS

A. Manufacturer: Subject to compliance with requirements, provide ceiling panels and grid systems by one of the following: 1. Concealed and Exposed Suspension Grid:

a. Armstrong World Industries, Inc. b. CertainTeed Corporation. c. Chicago Metallic; Rockfon (Roxul Inc.). d. Hunter Douglas. e. USG Interiors.

2. Acoustical Ceiling Panel:

a. Armstrong World Industries, Inc. b. CertainTeed Corporation. c. Rockfon (Roxul Inc.). d. Tectum Inc. e. USG Interiors.

3. Wood finish acoustical ceiling.

a. Acoustical Art Concepts. b. Comparable product approved by Architect.

4. Molding and Edge Trim: a. Armstrong World Industries, Inc. b. CertainTeed Corp. c. Chicago Metallic Corporation. d. Fry Reglet Corporation. e. Gordon, Inc. f. USG Interiors, Inc.; Subsidiary of USG Corporation.

5. Acoustical Sealant for Exposed and Concealed Joints:

a. Pecora Corporation; AC-20 FTR Acoustical and Insulation Sealant. b. USG Corporation; SHEETROCK Acoustical Sealant.

Addendum 03 - Page 7 of 33

Page 8: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 4

6. Acoustical Sealant for Concealed Joints:

a. Henkel Corporation; OSI Pro-Series SC-175 Acoustical Sound Sealant. b. Pecora Corporation; AIS-919.

B. Acoustical Panel Colors and Patterns: Match appearance characteristics indicated for each product type. 1. Where appearance characteristics of acoustical panels are indicated by referencing pattern

designations in ASTM E 1264 and not manufacturers' proprietary product designations, provide products selected by Architect that comply with requirements indicated for type, pattern, color, light reflectance, acoustical performance, edge detail, and size.

2.2 METAL SUSPENSION SYSTEM

A. Metal Suspension System: Direct hung metal suspension systems of types, structural classifications, and finishes indicated complying with applicable requirements in ASTM C 635/C 635M. 1. High Humidity Finish: Comply with ASTM C 635/C 635M requirements for Coating

Classification for Severe Environment Performance where high humidity finishes are indicated.

2. Attachment Devices: Size for five times the design load indicated in ASTM C 635/C 635M, Table 1 Direct Hung, unless otherwise indicated. Comply with seismic design requirements. a. Anchors in Concrete: Anchors of type and material indicated below, with holes or

loops for attaching hangers of type indicated and with capability to sustain, without failure, a load equal to five times that imposed by ceiling construction, as determined by testing according to ASTM E 488 or ASTM E 1512 as applicable, conducted by a qualified testing and inspecting agency. 1) Type: Cast in place, postinstalled expansion or postinstalled bonded anchors. 2) Corrosion Protection: Carbon steel components zinc plated to comply with

ASTM B 633, Class Fe/Zn 5 (0.005 mm) for Class SC 1 service condition. 3) Corrosion Protection: Stainless steel components complying with

ASTM F 593 and ASTM F 594, Group 1 Alloy 304 or 316 for bolts; Alloy 304 or 316 for anchor.

4) Corrosion Protection: Components fabricated from nickel copper alloy rods complying with ASTM B 164 for UNS No. N04400 alloy.

b. Power Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from corrosion resistant materials, with clips or other accessory devices for attaching hangers of type indicated and with capability to sustain, without failure, a load equal to 10 times that imposed by ceiling construction, as determined by testing according to ASTM E 1190, conducted by a qualified testing and inspecting agency.

3. Wire Hangers, Braces, and Ties: a. Zinc Coated, Carbon Steel Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft

temper. b. Stainless Steel Wire: ASTM A 580/A 580M, Type 304, nonmagnetic. c. Nickel Copper Alloy Wire: ASTM B 164, nickel copper alloy UNS No. N04400. d. Size: Select wire diameter so its stress at three times hanger design load

(ASTM C 635/C 635M, Table 1 Direct Hung) will be less than yield stress of wire, but provide not less than 0.106 inch (2.69 mm) diameter wire.

4. Hanger Rods and Flat Hangers: Mild steel, zinc coated or protected with rust inhibitive paint.

Addendum 03 - Page 8 of 33

Page 9: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 5

5. Angle Hangers: Angles with legs not less than 7/8 inch (22 mm) wide; formed with 0.04 inch (1 mm) thick, galvanized steel sheet complying with ASTM A 653/A 653M, G90 (Z275) coating designation; with bolted connections and 5/16 inch (8 mm) diameter bolts.

6. Hold Down Clips: Provide hold down clips spaced 24 inches (610 mm) o.c. on all cross tees in areas with exterior opening larger than 48” x 96”.

7. Impact Clips: Provide impact clip system designed to absorb impact forces against acoustical panels in Gymnasiums.

8. Aluminum cap for use over steel grid in kitchen areas or where shown on drawings or required.

B. Metal Suspension Systems: 1. Narrow Face, Steel Capped, Double Web, Steel Suspension System: Main and cross

runners roll formed from cold rolled steel sheet; prepainted, electrolytically zinc coated, or hot dip galvanized according to ASTM A 653/A 653M, not less than G30 (Z90) coating designation. a. Basis of Design: DX/DXL Suspension system as manufactured by USG. b. System: 15/16 inch exposed tee system. c. Structural Classification: Intermediate-duty system. d. Face Design: Flat, flush. e. Cap Finish: Color selected by Architect.

2.3 ACOUSTICAL PANELS

A. Acoustic Panel Type A: 1. Basis of Design Product: 560 Fissured Basic Acoustical Panels by USG Interiors. 2. Classification: Provide panels complying with ASTM E 1264 for type, form, and pattern:

a. Type and Form: Type XII, mineral base with painted finish; Form 2, water felted. b. Pattern: CD.

3. Color: White. 4. LR: Not less than 0.81. 5. NRC: Not less than 0.55. 6. CAC: Not less than 33. 7. Edge/Joint Detail: Square. 8. Thickness: 5/8 inch (16 mm). 9. Modular Size: 24 by 24 inches (610 by 610 mm). 10. Typical Location: Classrooms and Offices.

B. Acoustic Panel Type B: 1. Basis of Design Product: Halcyon Logix Panels No. 98221 by USG Interiors. 2. Classification: Provide panels complying with ASTM E 1264 for type, form, and pattern:

a. Type and Form: Type IV, glass fiber base; Form 2, water felted. b. Pattern: E & G. c. Color: White.

3. LR: Not less than 0.90. 4. NRC: Not less than 0.95. 5. Edge/Joint Detail: Square. 6. Thickness: 1 inch (25.4 mm). 7. Modular Size: 24 by 24 inches (610 by 610 mm). 8. Typical Location: Fines Arts.

C. Wood Finish Acoustical Panel Type C: 1. Basis of Design: Akupanel Concepts as manufactured by Acoustical Art Concepts. 2. Dimensions: 600 mm x 2400 mm.

Addendum 03 - Page 9 of 33

Page 10: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 6

3. Thickness: 20 mm. 4. Material: PET Polyester Fiber, MDF, Wood Veneer. 5. Colors: Architect to select from manufacturer’s full range. 6. Noise Reduction Coefficient: 0.97 at a frequency of 1,000 HZ. 7. Fire Rating: Class B, Flame Spread of 65, and Smoke Index of 522.

2.4 MOLDING, TRIM AND ACCESSORIES

A. Light Fixture Protection: 1. Manufacturer: Thermafiber Light Protection Kit by Owens Corning or Type 5/8 or 3/4 P(S)

by Armstrong World Industries. 2. Fire Resistance Rating: Same as ceiling assembly rating. 3. Locations: At fixtures reinstalled in fire rated ceiling assemblies.

B. Roll Formed, Sheet Metal Edge Moldings and Trim: Type and profile for standard moldings for edges and penetrations that comply with seismic design requirements; formed from sheet metal of same material, finish, and color used for exposed flanges of suspension system runners. 1. Provide edge moldings that fit acoustical panel edge details and suspension systems

indicated and that match width and configuration of exposed runners unless otherwise indicated.

2. For lay in panels with reveal edge details, provide stepped edge molding that forms reveal of same depth and width as that formed between edge of panel and flange at exposed suspension member.

3. For circular penetrations of ceiling, provide edge moldings fabricated to diameter required to fit penetration exactly.

C. Extruded Aluminum Edge Moldings and Trim: Where indicated, provide extruded aluminum edge moldings and trim of profile indicated or referenced by manufacturer's designations, including splice plates, corner pieces, and attachment and other clips, complying with seismic design requirements and the following: 1. Aluminum Alloy: Alloy and temper recommended by aluminum producer and finisher for

type of use and finish indicated, and with not less than the strength and durability properties of aluminum extrusions complying with ASTM B 221 (ASTM B 221M) for Alloy and Temper 6063-T5.

2. Clear Anodic Finish: AAMA 611, AA-M12C22A31, Class II, 0.010 mm or thicker. 3. Baked Enamel or Powder Coat Finish: Minimum dry film thickness of 1.5 mils (0.04 mm).

Comply with ASTM C 635/C 635M and coating manufacturer's written instructions for cleaning, conversion coating, and applying and baking finish.

D. Acoustical Sealant: Comply with ASTM C 834 and effective in reducing airborne sound transmission through perimeter joints and openings in building construction as demonstrated by testing representative assemblies according to ASTM E 90. 1. Exposed and Concealed Joints: Nonsag, paintable, nonstaining latex sealant. 2. Concealed Joints: Nondrying, nonhardening, nonskinning, nonstaining, gunnable,

synthetic rubber sealant.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, including structural framing to which acoustical panel ceilings attach or abut for compliance with requirements specified that affect ceiling installation and anchorage and with requirements for installation tolerances and other conditions affecting performance of acoustical panel ceilings.

Addendum 03 - Page 10 of 33

Page 11: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 7

B. Examine acoustical panels before installation. Reject acoustical panels that are wet, moisture damaged, or mold damaged.

C. Proceed with installation after correcting unsatisfactory conditions.

3.2 PREPARATION

A. Measure each ceiling area and establish layout of acoustical panels to balance border widths at opposite edges of each ceiling. Avoid using less than half width panels at borders, and comply with layout shown on reflected ceiling plans.

3.3 INSTALLATION

A. Install acoustical panel ceilings to comply with ASTM C 636/C 636M and seismic design requirements indicated, according to manufacturer's written instructions and CISCA Ceiling Systems Handbook. 1. Fire Rated Assembly: Install fire-rated ceiling systems according to tested fire rated

design.

B. Suspend ceiling hangers from building's structural members and as follows: 1. Install hangers plumb and free from contact with insulation or other objects within ceiling

plenum that are not part of supporting structure or of ceiling suspension system. 2. Splay hangers where required and, if permitted with fire resistance rated ceilings, to miss

obstructions; offset resulting horizontal forces by bracing, countersplaying, or other equally effective means.

3. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with location of hangers at spacings required to support standard suspension system members, install supplemental suspension members and hangers in form of trapezes or equivalent devices.

4. Secure wire hangers to ceiling-suspension members and to supports above with a minimum of three tight turns. Connect hangers directly either to structures or to inserts, eye screws, or other devices that are secure and appropriate for substrate and that will not deteriorate or otherwise fail due to age, corrosion, or elevated temperatures.

5. Secure flat, angle, channel, and rod hangers to structure, including intermediate framing members, by attaching to inserts, eye screws, or other devices that are secure and appropriate for both the structure to which hangers are attached and the type of hanger involved. Install hangers in a manner that will not cause them to deteriorate or fail due to age, corrosion, or elevated temperatures.

6. Do not support ceilings directly from permanent metal forms or floor deck. Fasten hangers to cast in place hanger inserts, postinstalled mechanical or adhesive anchors, or power actuated fasteners that extend through forms into concrete.

7. When steel framing does not permit installation of hanger wires at spacing required, install carrying channels or other supplemental support for attachment of hanger wires.

8. Do not attach hangers to steel deck tabs. 9. Do not attach hangers to steel roof deck. Attach hangers to structural members. 10. Space hangers not more than 48 inches (1200 mm) o.c. along each member supported

directly from hangers unless otherwise indicated; provide hangers not more than 8 inches (200 mm) from ends of each member.

11. Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced standards and publications.

C. Secure bracing wires to ceiling suspension members and to supports with a minimum of four tight turns. Suspend bracing from building's structural members as required for hangers, without attaching to permanent metal forms, steel deck, or steel deck tabs. Fasten bracing wires into concrete with cast in place or postinstalled anchors.

Addendum 03 - Page 11 of 33

Page 12: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 8

D. Panel Accessibility: Install panels downward accessible by disengaging hinge support rail on one side of panel from the T Bar Flange or optional A Mount rail flange without the use of tools, for access without removal of panel from the ceiling.

E. Install edge moldings and trim of type indicated at perimeter of acoustical ceiling area and where necessary to conceal edges of acoustical panels. 1. Apply acoustical sealant in a continuous ribbon concealed on back of vertical legs of

moldings before they are installed. 2. Screw attach moldings to substrate at intervals not more than 16 inches (400 mm) o.c. and

not more than 3 inches (75 mm) from ends, leveling with ceiling suspension system to a tolerance of 1/8 inch in 12 feet (3.2 mm in 3.6 m). Miter corners accurately and connect securely.

3. Do not use exposed fasteners, including pop rivets, on moldings and trim.

F. Install suspension system runners so they are square and securely interlocked with one another. Remove and replace dented, bent, or kinked members.

G. Install acoustical panels with undamaged edges and fit accurately into suspension system runners and edge moldings. Scribe and cut panels at borders and penetrations to provide a neat, precise fit. 1. Arrange directionally patterned acoustical panels with pattern running in one direction

parallel to long axis of space. 2. For square edged panels, install panels with edges fully hidden from view by flanges of

suspension system runners and moldings. 3. For reveal edged panels on suspension system runners, install panels with bottom of reveal

in firm contact with top surface of runner flanges. 4. For reveal edged panels on suspension system members with box shaped flanges, install

panels with reveal surfaces in firm contact with suspension system surfaces and panel faces flush with bottom face of runners.

5. Paint cut edges of panel remaining exposed after installation; match color of exposed panel surfaces using coating recommended in writing for this purpose by acoustical panel manufacturer.

6. Install hold-down clips in areas indicated, in areas with exterior opening larger than 48” x 96”, where required by authorities having jurisdiction, and for fire resistance ratings; space as recommended by panel manufacturer's written instructions unless otherwise indicated.

7. Install clean room gasket system in areas indicated, sealing each panel and fixture as recommended by panel manufacturer's written instructions.

8. Protect lighting fixtures and air ducts to comply with requirements indicated for fire resistance rated assembly.

H. Install Wood finish acoustical ceiling panels with undamaged edges. 1. Install 4S mm (thickness) studs directly on your wal I/ceiling with a distance of 600

in. 2. Install the acoustic panels directly on the studs with screws (inin. 3.Sx3S mm). You

can easily fit the screws between the lamellas in the underlying acoustic felt. Every panel is instat led with IS screws. Use black screws to achieve the best finish.

3. Cutting of the panels are easily done with a fine jagged saw. The underlying acoustic felt is easily cut with a good knife. For an expanded acoustic sol ution, you can place 4S mm insulation between the studs.

3.4 FIRE RATING SCHEDULE

A. Refer to UL Assemblies Drawings for Fire Rating requirements of ceiling materials at rated floor and roof assemblies.

Addendum 03 - Page 12 of 33

Page 13: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

ACOUSTICAL CEILING PANELS 09 51 00 - 9

3.5 FIELD QUALITY CONTROL

A. Special Inspections: Engage a qualified special inspector to perform the following special inspections: 1. Compliance of seismic design.

B. Testing Agency: Owner will engage a qualified testing agency to perform tests and inspections and prepare test reports.

C. Perform the following tests and inspections of completed installations of acoustical panel ceiling hangers and anchors and fasteners in successive stages. Do not proceed with installations of acoustical panel ceiling hangers for the next area until test results for previously completed installations show compliance with requirements. 1. Extent of Each Test Area: When installation of ceiling suspension systems on each floor

has reached 20 percent completion but no panels have been installed. a. Within each test area, testing agency will select one of every 10 power-actuated

fasteners and postinstalled anchors used to attach hangers to concrete and will test them for 200 lbf (890 N) of tension; it will also select one of every two postinstalled anchors used to attach bracing wires to concrete and will test them for 440 lbf (1957 N) of tension.

b. When testing discovers fasteners and anchors that do not comply with requirements, testing agency will test those anchors not previously tested until 20 pass consecutively and then will resume initial testing frequency.

D. Acoustical panel ceiling hangers and anchors and fasteners will be considered defective if they do not pass tests and inspections.

E. Prepare test and inspection reports.

3.6 CLEANING

A. Clean exposed surfaces of acoustical panel ceilings, including trim, edge moldings, and suspension system members. Comply with manufacturer's written instructions for cleaning and touchup of minor finish damage. Remove and replace ceiling components that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage.

END OF SECTION 09 51 00

Addendum 03 - Page 13 of 33

Page 14: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MISCELLANEOUS SPECIALITIES

10 01 00 - 1

SECTION 10 01 00 - MISCELLANEOUS SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Furnish and install the following: 1. Rapid Entry System (Fireman’s Lock Box). 2. Plasma/LCD Monitor Mounting Brackets. 3. Electrically operated, ceiling recessed, tab-tensioned, project screens 4. Storage Cabinets.

1.3 REFERENCES

A. NFPA 70 - National Electrical Code.

B. NFPA 701-99 - Fire Tests for Flame-Resistant Textiles and Films. 1.4 SUBMITTALS

A. Product Data: 1. Manufacturer’s specifications and other data needed to prove compliance with specified

requirements. 2. Manufacturer’s installation instructions. 3. Manufacturer's operation and maintenance data, as applicable.

B. Shop Drawings: Show sizes, locations and installation details. Include utility (electrical, water, gas)

requirements.

C. Samples: Color charts showing manufacturer's full range of colors. 1.5 PRE-INSTALLATION CONFERENCE

A. Refer to Section 01 31 00 – Project Management and Coordination.

1.6 COORDINATION

A. Coordinate Work of this Section with Work of other sections in which items are to be installed.

PART 2 - PRODUCTS 2.1 APPROVED MANUFACTURERS

A. Specifications are based on named products and manufacturers. Other manufacturers must have a minimum of five (5) years experience manufacturing products meeting or exceeding the specifications and comply with Division 1 requirements regarding substitutions to be considered.

Addendum 03 - Page 14 of 33

Page 15: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MISCELLANEOUS SPECIALITIES

10 01 00 - 2

2.2 MATERIALS

A. Rapid Entry System (Fireman’s Lock Box, main entry): Knox Company No.3200 recessed, with recessed mounting kit. Verify the model number required with Authority Having Jurisdiction.

B. Manual Projection Screens:

1. Pull-down ceiling mounting type. 2. Construction: Screen to have a heavy 22 gauge octagonal steel case with flat back design

with baked enamel finish and fitted with end caps concealing roller ends with integral bearing surface to support roller and integral brackets for wall mounting by means of slotted screw holes. Bottom of fabric shall be mounted into a metal strip in a tubular steel slat finished in baked enamel. Ends of slat shall be protected by plastic caps. Plated steel slat pull shall be attached to slat with screws.

3. Screen: To have Matte White surface with masking borders on flame retardant and mildew resistant seamless fabric. Fabric shall be mounted into a metal strip in a metal Camlok roller system without tape, glue, staples or cords so that fabric may be easily replaced yet cannot be pulled from roller.

4. Accessories: Provide chains and clips to mount screen to acoustical lay-in ceiling grid. 5. Mounting/Number/Size/Location: As shown on drawings. 6. Approved Product/Manufacturer: Model “B” Spring Roller Type Screen as manufactured by

Da-Lite Screen Company, Inc.; (800) 622-3737 or equal by Draper, Spiceland, IN; (765) 987-7999, Bretford Manufacturing, Inc.; (800) 521-9614, or comparable product.

C. Plasma/LCD Monitor Mounting Brackets: 1. Ceiling & Wall Mounted Brackets for mounting on wood studs or masonry wall:

a. Features: 1) Universal adapter plate included 2) Pull-out swivel with up to 45° rotation depending on screen size 3) Locking tab provides optional swivel restriction to one side 4) 3.4" deep in closed position, up to 11.9" fully extended 5) 0°, 5° or 10° lockable incremental tilt 6) +/-1° roll for horizontal screen alignment during installation 7) Built-in cord management 8) Lock KeyTM installation tool secures arms for screen installation 9) Lock-out screw prevents unwanted extension 10) Mounts to 16" wood studs, concrete, cinder block 11) Includes mounting and screen attachment hardware

b. Size: Capable of securely holding a 32-58 inch television, as required, and furnished

by Owner. c. Color: Black d. Number/Location: As shown on drawings. e. Approved Product/Manufacturer: Model No. SP850-UNLP-GB as manufactured by

Peerless Industries, Inc., Melrose Park, IL; (708) 865-887 or equivalent manufactured by Bretford Manufacturing, Inc., Schiller Park, IL; (800) 521-9614; Lucasey Mfg. Corp., Oakland, CA: (800) 582-2739; Chief Brand of Milestone AV Technologies, Eden Prairie, MN; (800) 582-6480; or Architect approved equal.

f. D. Paragon V: Large electrically operated, tab tensioned, extruded aluminum case. Projection screen

with motor in roller. Case fully enclosed except for slot allowing viewing surface passage. Roller: 6 inches (152 mm) diameter steel tube. Viewing surface securely attached to roller at top and at bottom to weighted dowel. Provided with universal mounting brackets for ceiling or above ceiling mounting. 1. Motor UL certified, rated 110-120V AC, 60 Hz, three wire, instantly reversible, lifetime

lubricated with pre-set accessible limit switches.

Addendum 03 - Page 15 of 33

Page 16: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MISCELLANEOUS SPECIALITIES

10 01 00 - 3

2. Motor Screen Controls, UL Certified. a. Single station control rated 115V AC, 60 Hz with 3-position rocker switch with cover

plate to stop or reverse screen at any point. 3. Projection Viewing Surface.

a. TecVision XT1100X White - On-Axis gain of 1.1. 180 degree viewing cone. Designed for use when the projector brightness and size of screen require a minimal increase in gain. Imaging Science Foundation certified and 4K ready. Dark backing.

4. Tab-Tensioning System. a. Viewing surface with integrated tabs and cable on each side of fabric to provide

tension and ensure flat viewing surface. Viewing surface and tabs CNC cut as a single piece. Tabs RF welded to the back of viewing surface to prevent tab separation. Tab adhesives are not acceptable. Warranted for 5 years against tab separation. Viewing surface inserted into aluminum bottom dowel.

5. Viewing Area H x W. a. HDTV Format (16:9). Black masking borders standard.

1) 108 inches x 192 inches.

E. Storage Cabinets: 1. Type: Factory assembled industrial storage cabinet. 2. Material: Constructed of heavy-gauge steel throughout for maximum rigidity and trouble

free performance. 3. Features:

a. Double satin chrome handle, one (1) fixed and one (1) with key lock. Furnish three (3) keys per cabinet.

b. 16-gauge steel frame construction. c. Four (4) knuckle hinges. d. Louvered backs for ventilation. e. Leveling screws for easy opening doors. f. Dual reinforced doors ensure quiet operation. g. Built-in shelf support tabs, no bolts or clips needed. h. Raised bases to protect doors from damaged by mops during cleaning. i. Shelf loads to 200 lbs. j. Nylon lock bar guide for quiet operation.

4. Size: 36 inches wide x 24 inches deep x 78 inches high. 5. Shelves: Four (4) 6. Finish/Color: Powder coated in color selected by Architect from manufacturer’s standard

colors. 7. Number/Location: As shown on drawings. 8. Approved Product/Manufacturer: Model 7824 manufactured by Tennsco, Dickson, TN;

(800) 251-8184, or equal by Edsal Manufacturing Company, Chicago, IL; (773) 254-0600. PART 3 - EXECUTION 3.1 EXAMINATION

A. Verify utility (electrical, water, and gas) requirements, where applicable, are installed and ready for connection.

B. Verify items fastened to walls have proper blocking or support items installed. C. Verify locations for items are ready for their installation.

3.2 INSTALLATION

Addendum 03 - Page 16 of 33

Page 17: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MISCELLANEOUS SPECIALITIES

10 01 00 - 4

A. Install all items in accordance with manufacturer's printed instructions in locations shown on drawings or otherwise indicated.

B. Provide blocking for LCD TVs mounting as indicated in drawings or per manufacturer’s

instructions.

C. Install projection screen housing in conjunction with installation of ceiling system. After interior construction is essentially complete, install viewing surface and operating mechanism in housing. Install screens securely to supporting substrate so that screens are level and back of case is plumb. Provide required brackets, hanger rods, and fasteners.

D. Test electrically operated units to verify that screen, controls, limit switches, closure and other operating components are in optimum functioning condition.

3.3 CLEANING AND ADJUSTING

A. Make final adjustment after installation and clean all backstop support piping of dirt and other substances which may affect final finish.

B. Clean all items of dirt and foreign matter which may affect appearance and operation. C. Adjust items for proper operation.

D. Instruct Owner’s personnel on proper operation and maintenance of items.

END OF SECTION 10 01 00

Addendum 03 - Page 17 of 33

Page 18: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

METAL STORAGE SHELVING 10 56 13 - 1

SECTION 10 56 13 - METAL STORAGE SHELVING

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes: Requirements including but not limited to: 1. Four post metal storage shelving. 2. Accessories necessary for a complete installation.

1.3 PERFORMANCE REQUIREMENTS

A. Delegated Design: Design metal storage shelving, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated.

B. Seismic Performance: Metal storage shelving shall withstand the effects of earthquake motions determined according to ASCE/SEI 7.

1.4 SUBMITTALS

A. Product Data: Technical data for each type of shelving unit and accessory components including recessed tracks. Include rated capacities, installation and construction details, material descriptions, dimensions of individual components and profiles, and finishes.

B. Shop Drawings: Submit plans, elevations, sections, and details, including installation details of connectors, lateral bracing, and special bracing.

C. Seismic Qualification Certificates: For metal storage shelving, accessories, and components, from manufacturer.

1.5 COORDINATION

A. Coordinate sizes and locations of blocking and backing required for installation of metal storage shelving attached to wall and ceiling assemblies.

B. Coordinate locations and installation of metal storage shelving that may interfere with ceiling systems including lighting, HVAC, speakers, sprinklers, access panels, electrical switches or outlets, and floor drains.

1.6 FIELD CONDITIONS

A. Environmental Limitations: Do not deliver or install metal storage shelving until spaces are enclosed and weathertight, wet work in spaces is complete and dry, and temporary HVAC system is operating and maintaining ambient temperature and humidity conditions at levels intended for building occupants during the remainder of the construction period.

Addendum 03 - Page 18 of 33

Page 19: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

METAL STORAGE SHELVING 10 56 13 - 2

PART 2 - PRODUCTS

2.1 MATERIALS

A. Hot Rolled Steel Sheet: ASTM A 1011/A 1011M, Commercial Steel (CS), Type B; free of scale, pitting, or surface defects; pickled and oiled.

B. Cold Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B.

C. Metallic Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with G60 (Z180) zinc (galvanized) or A60 (ZF180) zinc-iron-alloy (galvannealed) coating.

D. Steel Tubing: ASTM A 513, Type 2.

2.2 STORAGE SHELVING UNITS

A. Four Post Metal Storage Shelving: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the

following: a. AMCO Corporation. b. Dixie Shelving Co, c. Equipto. d. InterMetro Industries Corporation. e. Lyon Workspace Products, LLC. f. Montel, Inc. g. Penco Products, Inc. h. Republic Storage Systems Co. i. Safco Products. j. Tennsco.

2. Open Four Post Metal Storage Shelving: Comply with MH 28.1; field assembled from

factory formed components. Shelves span between supporting corner posts that allow shelf height adjustment over full height of shelving unit. Provide fixed top and bottom shelves, adjustable intermediate shelves, and accessories indicated.

3. Load Carrying Capacity per Shelf: Minimum 700 lb (318 kg). (OR 400 Ibs (182 kg per Cy-Fair ISD).

4. Posts: Fabricated from hot rolled steel; in standard shape; with perforations at 1-1/2 inches (38 mm) o.c. to receive shelf to post connectors. a. Unit Configuration: Configure shelving units as individual, freestanding assemblies.

1) Add On Shelf Posts: Fabricated from hot rolled steel, standard shape; perforated to match main posts.

b. Post Base: Adjustable steel floor plate, drilled for floor anchors.

5. Bracing: Standard, single or double diagonal cross bracing. a. Location: At unit back and ends necessary for stability, load carrying capacity of

shelves, and number of shelves indicated. b. Back Panel: One piece fabricated from cold rolled steel sheet; of nominal: 0.024

inch (0.61 mm) steel sheet thickness.

6. End Panels: Fabricated from cold rolled steel sheet of nominal: 0.024 inch (0.61 mm) steel sheet thickness. (CLOSED – Choose between #6 and #2)

7. Solid Type Shelves: a. Steel Sheet: Nominal thickness minimum 0.048 inch (1.21 mm) or as necessary for

load carrying capacity per shelf.

Addendum 03 - Page 19 of 33

Page 20: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

METAL STORAGE SHELVING 10 56 13 - 3

b. Metallic Coated Steel Sheet: Nominal thickness minimum 0.052 inch (1.32 mm)or as necessary for load carrying capacity per shelf.

c. Fabricate fronts and backs of shelves with vertical edges that are flanged and returned, with edges reinforced with steel bars, angles, or channels.

8. Framed Type Wire Shelves: Metallic coated steel] wire; with shelf frame fabricated from same material and with same finish as posts.

9. Truss Type Wire Shelves: Metallic coated steel wire over wire construction, with downturned wire truss edges.

10. Shelf Quantity: Six shelves per shelving unit in addition to top and bottom shelf. 11. Shelf to Post Connectors: Mechanical fasteners (nuts and bolts). 12. Base: Closed, with base strips fabricated from same material and with same finish as

shelving. 13. Overall Unit Width: As indicated in the Drawings. 14. Overall Unit Depth: As indicated in the Drawings. 15. Overall Unit Height: 84 inches (2134 mm). 16. Accessories:

a. Finished End Panels: Fabricated as perforated full height panels from standard thickness cold rolled steel sheet and with same finish as posts, with trim for a finished appearance along edges abutting posts and top shelf.

17. Steel Finish: Baked enamel or powder coat. a. Color and Gloss: Selected by Architect.

2.3 ANCHORS

A. Floor Anchors: Galvanized steel, post installed expansion anchors or power actuated fasteners. Provide number per unit recommended by manufacturer unless additional anchors are indicated in calculations.

B. Wall Anchors: Galvanized steel anchors designed to secure metal storage shelving to adjacent wall. Provide one per shelving unit for each shelving unit adjacent to a wall unless additional anchors are indicated in calculations.

2.4 FABRICATION

A. Fabricate metal storage shelving components to provide field assembled units that are square and rigid, with posts plumb and true and shelves flat and free of dents or distortion. Fabricate connections to form a rigid structure, free of buckling and warping. 1. Form exposed connections with hairline joints, flush and smooth, using concealed

fasteners where possible. Locate joints where least conspicuous. 2. Build in straps, plates, brackets, and other reinforcements as needed to support shelf

loading. 3. Cut, reinforce, drill, and tap metal fabrications to receive hardware, fasteners, and similar

items.

B. Form metal in maximum lengths to minimize joints. Form bent metal corners to smallest radius possible without causing grain separation or otherwise impairing the work. Form backs of shelving units of up to 48 inches (1219 mm) wide from one piece.

C. Form edges and corners free of sharp edges or rough areas. Fold back and crimp exposed edges of unsupported sheet metal to form a hem on the concealed side; ease edges of metal plate to radius of approximately 1/32 inch (0.8 mm). Shear and punch metals cleanly and accurately. Remove burrs.

D. Weld corners and seams continuously to develop strength, minimize distortion, and maintain the corrosion resistance of base metals. At exposed locations, finish welds and surfaces smooth

Addendum 03 - Page 20 of 33

Page 21: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

METAL STORAGE SHELVING 10 56 13 - 4

and blended so surface is smooth after finishing and contour of welded surface matches that of adjacent surface. Weld before finishing components to greatest extent possible. Remove weld spatter and welding oxides from exposed surfaces before finishing.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas for compliance with requirements for installation tolerances and other conditions affecting performance of the work. Examine floors for suitable conditions where metal storage shelving will be installed.

B. Examine walls and ceilings to which metal storage shelving will be attached for properly located blocking, grounds, or other solid backing for attachment of support fasteners.

C. Proceed with installation after correcting unsatisfactory conditions.

3.2 PREPARATION

A. Vacuum and clean finished floor over which metal storage shelving is to be installed.

3.3 INSTALLATION

A. Install metal storage shelving level, plumb, square, rigid, true, and with shelves flat and free of dents or distortion. Make connections to form a rigid structure, free of buckling and warping. 1. Install exposed connections with hairline joints, flush and smooth, using concealed

fasteners where possible. 2. Install braces, straps, plates, brackets, and other reinforcements as needed to support

shelf loading and as required for stability. 3. Adjust post base bolt leveler to achieve level and plumb installation. 4. Anchor shelving units to floor with floor anchors through floor plate. Shim floor plate to

achieve level and plumb installation. 5. Install seismic restraints. 6. Connect side to side and back to back shelving units together. 7. Install shelves in each shelving unit at spacing indicated on Drawings.

a. Four Post Metal Storage Shelving: Install four clips, one at each post, for support of each shelf; with clips fully engaged in post perforations.

3.4 ERECTION TOLERANCES

A. Erect four post metal storage shelving to a maximum tolerance from vertical of 1/2 inch (13 mm) in up to 10 feet (3 m) of height, not exceeding 1 inch (25 mm) for heights taller than 10 feet (3 m).

B. Erect post and beam metal storage shelving to a maximum tolerance from vertical of 1/4 inch (6 mm) in 84 inches (2134 mm) of height.

3.5 ADJUSTING

A. Adjust metal storage shelving so that connectors and other components engage accurately and securely.

B. Adjust and lubricate operable components to operate smoothly and easily, without binding or warping. Check and readjust operating hardware.

Addendum 03 - Page 21 of 33

Page 22: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

METAL STORAGE SHELVING 10 56 13 - 5

C. Touch up marred finishes or replace metal storage shelving that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by metalstorage shelving manufacturer.

D. Replace metal storage shelving components that have been damaged beyond successful repairby finish touchup or similar minor repair procedures.

END OF SECTION 10 56 13

Addendum 03 - Page 22 of 33

Page 23: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MOBILE STORAGE SHELVING 10 56 26 - 1

SECTION 10 56 26 - MOBILE STORAGE SHELVING

CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

PART 1 - GENERAL

1.1 SECTION INCLUDES

A. High-density, mechanically assisted, mobile storage system.

1.2 SUBMITTALS

A. Product Data:1. Manufacturer's specifications and other data needed to prove compliance with

the specified requirements.2. Manufacturer's installation instructions.

B. Shop Drawings: Show locations and sizes of all units. Field verify dimensions prior topreparation of shop drawings.

C. Samples: Actual material sample showing specified finish and color for Architect’sapproval.

1.3 WARRANTY

A. Warrant the work specified herein for five (5) years against becoming unserviceable orcausing an objectionable appearance resulting from either defective or nonconforming materials and workmanship.

PART 2 - PRODUCTS

2.1 APPROVED MANUFACTURERS

A. Listed products and manufacturers whose products meet or exceed the specificationsare approved for use on this Project. Other manufacturers must have a minimum of five(5) years experience manufacturing equivalent products to those specified and complywith Division 1 requirements regarding substitutions to be considered. 1. Richards-Wilcox (Aurora Mobile), Inc; Aurora, IL2. Montel, Satellite, FL3. SpaceSaver Corporation; Fort Atkinson, WI

2.2 MOBILE STORAGE SYSTEMS

A. Tracks:1. Cold rolled steel2. No less than 1 inch thick by 1-1/2 inch wide and offered in 72 inch sections (cut

to lengths).3. Rest on steel plates no less than 1/8 inch thick and 3-1/2 inch wide4. Attach directly to the concrete floor.

B. Decking: recessed, pre-cut lengths of 3/4" particle board, fire retardant.

C. Ramp: galvanized, no less than 1 to 12.

D. Carriage: 14 gauge steel channels, 4-1/6 inch high, bolted, shall support at least 1,000pounds of load per linear carriage foot.

Addendum 03 - Page 23 of 33

Page 24: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

PBK/IN2 BISD – Plaza Renovations Project No. 18204/1808 Birdville Independent School District

MOBILE STORAGE SHELVING 10 56 26 - 2

E. End Panels: Steel Modular sections painted with baked-on enamel, 96 inches high.

F. Configuration: mechanical assisted movement with disk type handle, 4 to 5 pounds ofpressure on the handle shall move 18,000 lbs. of filing.

G. Filing, storage, drawer configurations shall be selected by Owner.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install shelving units in accordance with manufacturer's printed instructions.

END OF SECTION

Addendum 03 - Page 24 of 33

Page 25: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

2'-1

1/2

"6

'-0 1

/2"

2'-7

1/2

"4

1/2

"

08.01 08.01 08.01 08.0109.16 09.37 08.02 08.01 09.14

09.18

09.16

2'-2

"6

'-0"

2'-7

1/2

"4

1/2

"

LIGHT FIXTURE, RE: MEP (TYP)

11.03 11.03 11.03 11.03

4 1

/2"

09.18

09.14

09.16

08.01 08.02 08.01 08.0209.37

4 1

/2"

2'-7

1/2

"

6'-0

"2

'-2"

4 1

/2"

2'-7

1/2

"6

'-0 1

/2"

2'-1

1/2

"

11.03 11.03 11.0311.0326.01 26.01

9'-0

1/2

"2

'-1 1

/2"

08.01 08.0108.02 08.01 08.02

09.16

09.16 09.14

09.18

13'-2"

09.37

4 1

/2"

2'-7

1/2

"6

'-0 1

/2"

2'-1

1/2

"

09.1409.14

11.03

3'-0

"6

'-0 1

/2"

2'-1

1/2

"

08.02 08.01 08.01 08.02 08.0109.37

09.37 09.16

09.1609.16

09.1409.14

09.18

13'-2"

2'-1

1/2

"6

'-0 1

/2"

2'-7

1/2

"4

1/2

"

09.3711.03

2'-1

0"

2'-1

1/2

"

09.1409.14

09.18

09.16

11'

-2"

09.16

09.1409.18

09.1409.14

2'-1

0"

08.01

11.0611.06

09.16

11.04

09.37

2'-1

1/2

"9

'-0 1

/2"

6'-0" 14'-9 3/4"

P113.1A

1'-1

0 1

/2"

2'-2

"6

'-0"

2'-7

1/2

"4

"

110236X34

110236X34

110236X34

110236X34

110236X34

2'-1

0"4

"

09.18 09.16

09.37 08.01

09.1409.14

106215X34

09.21FILLER

4100039X34

P114A

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL in2arch.com

B

C D

ARCHITECTURE

12222 MERIT DR, SUITE1140DALLAS, TX 75251

972-427-1222 P

4/8

/2019

7:4

0:5

9 P

M

C:\U

se

rs\e

dore

\Do

cum

en

ts\1

8204

BIS

D P

laza

\1820

4 B

I SD

Pla

za-P

LC

Bld

g_A

17.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A6.22

INTERIOR

ELEVATIONS

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

1/4" = 1'-0"6 PROFESSIONAL LEARNING CENTER NORTH

1/4" = 1'-0"12 PROFESSIONAL LEARNING CENTER SOUTH

1/4" = 1'-0"18 PROFESSIONAL LEARNING CENTER EAST

1/4" = 1'-0"24 PROFESSIONAL LEARNING CENTER WEST

1/4" = 1'-0"13 TRAINING RM 114 SOUTH ELEVATION

1/4" = 1'-0"21 TRIANING RM 114 NORTH ELEVATION

1/4" = 1'-0"30 TRAINING RM 114 EAST ELEVATION

KEY NOTE LEGEND

KEYNOTE DESCRIPTION

08.01 DOOR & FRAME AS SCHED. (TYP)

08.02 FRAMED GLAZING SYSTEM & GLASS AS SCHED.

09.14 VWC- 1 VINYL WALL COVERING - WINTER WIND

09.16 PL-2 LAMINATE - ROOT

09.18 AP-1 ACOUSTICAL PANELING - COBALT

09.21 SS-2 SOLID SURFACE - WHITE CLIFF

09.37 1/2" MTL REVEAL

11.03 MOTORIZED PROJECTION SCREEN, REF. MEPT

11.04 TELEVISION, REF. MEPT

11.06 MARKER BOARD

26.01 LIGHT FIXTURE, REF. MEP (TYP)

1/4" = 1'-0"28 TRAINING RM 114 WEST ELEVATION

No. Description Date3 ADDENDUM #03 04/09/2019

3333

3 3 3 3

3

3

Addendum 03 - Page 25 of 33

Page 26: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

GENERAL CASEWORK NOTES

1. BASIS-OF-DESIGN FOR ALL NON-SCIENCE CASEWORK SHALL BELSI CORPORATION OF AMERICA, INC., U.N.O.

2. BASIS-OF-DESIGN FOR ALL SCIENCE CASEWORK SHALL BE LSI CORPORATION OF AMERICA, INC., U.N.O.

3. FIELD VERIFY ALL CASEWORK-RELATED DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION

4. VERIFY ALL COLUMN LOCATIONS PRIOR TO FABRICATION AND INSTALLATION5. REFER TO MEPT DOCUMENTS FOR ALL DATA OUTLETS AND DEVICES, ELECTRICAL

OUTLETS AND DEVICES, AND PLUMBING FIXTURES, NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO FABRICATION AND INSTALLATION

6. ALL CASEWORK BASE CABINETS SHALL BE 24 INCHES IN DEPTH, U.N.O.7. ALL CASEWORK UPPER WALL CABINETS SHALL BE 14 INCHES IN DEPTH, U.N.O.8. ALL COUNTER TOPS, VERTICAL SURFACES, NOSINGS, AND BACK SPLASHES SHALL BE

PLASTIC LAMINATE FINISH, U.N.O.9. PROVIDE AND INSTALL SIDE SPLASHES WHERE COUNTER TOP ENDS ABUT WALL

SURFACES10. PROVIDE AND INSTALL 4 INCH HIGH TOE SPACE WITH WALL BASE AT ALL CASEWORK,

WALL BASE TO MATCH ROOM WALL BASE11. PROVIDE AND INSTALL WALL ANCHORED VERTICAL SUPPORTS AT ALL KNEE SPACES

GREATER THAN 48 INCHES WIDE12. PROVIDE AND INSTALL GROMMETS WITH SLEEVES AT ALL KNEE SPACES13. ALL CASEWORK UNITS 36 INCHES WIDE AND GREATER WITH SHELVING SHALL HAVE

A CENTER FIXED SHELF14. ALL SHELVING 36 INCHES WIDE AND GREATER SHALL BE SHALL BE 1 INCH THICK

MINIMUM15. ALL ADJUSTABLE SHELVING SHALL HAVE RECESSED STANDARDS HARDWARE16. PROVIDE AND INSTALL FILLER PANELS WITH TOP RETURNS AT ALL SIDES, CORNERS,

AND COLUMNS TO PREVENT THE CONTACT OF DOORS WITH ADJACENT SURFACES17. PROVIDE AND INSTALL LOCKS AT ALL BASE CABINETS AND ALL UPPER WALL

CABINETS

2"

10"

2"

2'-4

"

3'-6

"

2" 3'-2" 2" 4"

2"4'-0" 2"

1'-0

"2

"2

'-4"

2'-4" 2" 1'-4" 2" 2"

1'-4" 8"

3'-2

"

2"1"

1'-11"

2'-2"

3'-1

"1

"1

'-1"

4'-3

"

2" 6" 1'-6"

2"

1'-4"2"

2' -

10

"

4"

9"

2" DIA S.S. PIPE FOOT REST FLOOR MOUNTED

WING WALL BEYOND (REF FLOOR PLANS)

HARDWARE CHARGING COUNTER

AD

A C

HA

RG

ING

CO

UN

TE

RS

2'-6

"4

"

2'-1

0"

2'-1"

2"

R 1

/2"

2'-2

"4

"

PLYWOOD BACKING FOR SUPPORT

RECESSED POPUP RECEPTACLE. RE: ELECTRICAL

FLUSH MOUNT MTL BRACKET. PROVIDE BLOCKING

WALL FINISH AS SCHED.

2" DIA S.S. PIPE FOOT REST FLOOR MOUNTED 4"

26"

CR

ITIC

AL

9"

BACK-UP WALL (RE: PLANS)

1/4" CLEAR TEMPEREDGLASS SHELF WITH EASED EDGES AND

HEAVY DUTY BRACKETSRE: SPECS

1'-6"

1/4" CLEAR TEMPERED SLIDING GLASS DOOR

LOCKABLE RE: ELEV. FOR NUMBER OF DOORS

CLEAR ANOD. ALUM.DOOR TRACK AND

ACCESSORIES; RE: SPECS

2"x48" RECESSED LED LIGHT FIXTURE TYPE C

RE: ELECTRICAL

RE

F.

INT

ER

IOR

EL

EV

AT

ION

SR

EF

. IN

TE

RIO

R E

LE

VA

TIO

NS

PL-2 LAMINATE - ROOT

PL-2 LAMINATE - ROOT

2'-1

0"

A.F

.F.

4"

6" 1'-3" 3"

SMOOTH EDGES

SL

OP

E1

1/2

"

3'-4"

2'-7

1/2

"2

1/2

"

1 1

/2"

SMOOTH EDGES

2'-1

0"

A.F

.F.

4"

6"

1'-3

"3

"

3'-4"

SMOOTH EDGES SMOOTH EDGES

SECTIONELEVATION PLAN

1/2" SOLID SURFACE BACK SPLASH

EDGE RAIL: P. LAM. ON 1/2" MDF OVER CONT. 2x SUPPORT FRAMING

WALL BEYOND

*FOR ALL MILLWORK VANITIES WITH AN OPEN SPAN OF 60" OR MORE SHALL BE BRACED BACK TO REAR WALL AS INDICATED WITH THIS DETAIL.

COUNTER BRACE LOCATIONS: DOUBLE 2x4 FRAMING @ 48" O.C. (MAX) 1x6 VERTICAL NAILER CENTERED AGAINST BRACE TO ACCEPT PANEL SCREWS. CENTER BRACE BETWEEN SINKS WHERE APPLICABLE. PROVIDE BLOCKING IN WALL FOR SUPPORT. EXPOSED END LOCATIONS: PLASTIC LAMINATE EXPOSED SIDE BRACE.

CONTINUOUS BLOCKING CONCEALED IN WALL, TYP.2'-0"

1/2" SOLID SURFACE BACK SPLASH

EDGE RAIL: P. LAM. ON 1/2" MDF OVER CONT. 2x SUPPORT FRAMING

SOLID SURFACE COUNTER TOP ON 2-LAYERS OF 1/2" MDF

SOLID SURFACE COUNTER TOP ON 2-LAYERS OF 1/2" MDF

COUNTER BRACE LOCATIONS: DOUBLE 2x4 FRAMING @ 48" O.C. (MAX) 1x6 VERTICAL NAILER CENTERED AGAINST BRACE TO ACCEPT PANEL SCREWS. CENTER BRACE BETWEEN SINKS WHERE APPLICABLE. PROVIDE BLOCKING IN WALL FOR SUPPORT. EXPOSED END LOCATIONS: PLASTIC LAMINATE EXPOSED SIDE BRACE.

CONTINUOUS BLOCKING CONCEALED IN WALL, TYP.

2'-0

"

SOLID SURFACE COUNTER TOP ON 2-LAYERS OF 1/2" MDF

1/2" SOLID SURFACE BACK SPLASH

EDGE RAIL: P. LAM. ON 1/2" MDF OVER CONT. 2x SUPPORT FRAMING

MIRROR (WHERE APPLICABLE) 40" MAX TO VIEWING SURFACE

WALL BEYOND

SECTIONELEVATION

2'-1

0"

A.F

.F.

4"

6 1/2" 5" 4 1/2" 8"

2'-0"

2'-5

" C

LE

AR

9"

1"

2'-3

" C

LE

AR

*FOR ALL MILLWORK VANITIES WITH AN OPEN SPAN OF 60" OR MORE SHALL BE BRACED BACK TO REAR WALL AS INDICATED WITH THIS DETAIL.

REMOVABLE PANEL. P. LAM. ON 1/2" MDF WITH CONT. 1x6 CLEATS T&B 1x2 @ CENTER AND VERTICAL @ ENDS. ATTACH PANEL WITH 1 1/2" LONG S.S. SCREWS AND S.S. BEVELED WASHERS (MIN. 6/ PANEL, TYP.)

COUNTER BRACE: CONCEALED LOCATIONS: DOUBLE 2x4 FRAMING @ 48" O.C. (MAX) 1x6 VERTICAL NAILER CENTERED AGAINST BRACE TO ACCEPT PANEL SCREWS. CENTER BRACE BETWEEN SINKS WHERE APPLICABLE. PROVIDE BLOCKING IN WALL FOR SUPPORT. EXPOSED END LOCATIONS: PLASTIC LAMINATE EXPOSED SIDE BRACE.

CONTINUOUS BLOCKING CONCEALED IN WALL, TYP.

ADA COMPLIANT SINK BEYOND

1/2" SOLID SURFACE BACK SPLASH

SOLID SURFACE COUNTER TOP ON 2-LAYERS OF 1/2" MDF

EDGE RAIL: P. LAM. ON 1/2" MDF OVER CONT. 2x SUPPORT FRAMING

ADA COMPLIANT SINK BEYOND

COUNTER BRACE: CONCEALED LOCATIONS: DOUBLE 2x4 FRAMING @ 48" O.C. (MAX) BETWEEN TWO LAYERS OF 3/4" PLYWOOD WITH 1x6 VERTICAL NAILER CENTERED AGAINST BRACE. CENTER BRACE BETWEEN SINKS WHERE APPLICABLE. PROVIDE BLOCKING IN WALL FOR SUPPORT. EXPOSED END LOCATIONS: PLASTIC LAMINATE EXPOSED SIDE BRACE

COUNTER TOP AS SPEC'D

BASE AS SCHED.

PLAS. LAM. ON 3/4" PLYWOOD DRAWER/ DOOR FRONT w/ HANDLE AS SPEC'D w/ 1/4" GAP BETWEEN

DRAWER AND DOOR FRONTS, TYP.

ADJUSTABLE PLAS. LAM. SHELF

K&V #255 STANDARDS W/ #256 STEEL SUPPORTS

1/4" PLYWOOD BACK LET INTO TOP AND BOTTOM PANELS OF CABINET

PLAS. LAM ON 3/4" PLYWOOD

6"

1'-0

"

EQ

EQ

RE

F. E

LE

V.

RE

F. E

LE

V.

RE

F. E

LE

V.

SUSP CEILING AS SCHED. RE: RCP

PLAS. LAM ON 5/8" GYP BOARD

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD RE: ELEVATION FOR FINISH

TILE, RE: ELEVATION FOR FINISH

WALL ASSEMBLY , RE: FLOOR PLAN

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH

APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT

MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

1 x NAILER TYPICAL

PLASTIC LAMINATE ON 3/4" PLYWOOD SHELVES ON ADJUSTABLE SUPPORT BRACKETS (TYPICAL)

BACKSPLASH, RE: INTERIOR ELEVATION

SINK BEYOND

2'-6"

6" MTL STUD

3' - 0"

UNDER COUNTER LED LIGHTING TYP. TYPE J RE:ELEC

COUNTER TOP AS SPEC'D

BASE AS SCHED.

PLAS. LAM. ON 3/4" PLYWOOD DRAWER/ DOOR FRONT w/ HANDLE AS SPEC'D w/ 1/4" GAP BETWEEN

DRAWER AND DOOR FRONTS, TYP.

ADJUSTABLE PLAS. LAM. SHELF

K&V #255 STANDARDS W/ #256 STEEL SUPPORTS

1/4" PLYWOOD BACK LET INTO TOP AND BOTTOMPANELS OF CABINET

PLAS. LAM ON 3/4" PLYWOOD

6"

1'-0

"

EQ

EQ

2'-8"

RE

F. E

LE

V.

RE

F. E

LE

V.

RE

F. E

LE

V.

3'-0"

SUSP CEILING AS SCHED. RE: RCP

PLAS. LAM ON 5/8" GYP BOARD

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD RE: ELEVATION FOR FINISH

TILE, RE: ELEVATION FOR FINISH

WALL ASSEMBLY , RE: FLOOR PLAN

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH

APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT

MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

09.1209.09

08.0108.022

'-10"

2'-2

"2

'-0"

110236X34

110236X34

110236X34

110236X34

110236X34

305236X24

305236X24

305236X24

305236X24

305236X24

09.15

14'-6 1/2"

5"

4'-0"4'-0"4'-0"

5"

14'-5 1/4"

305230X24

305236X24

305236X24

110230x34

110236x34

110236x34

110236x34

110230x34

305230X24

305236X24

110230x34

110236x34

110236x34

110236x34

110230x34

305230X24

305236X24

305236X24

305236X24

305230X24

2'-0

"2

'-2"

2'-1

0"

FILLERFILLER

FILLERFILLERFILLERFILLER

FILLERFILLER

09.0809.08

10.1908.01 09.15

09.17

10.19

1'-0

"

7'-0

"

10.19

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL in2arch.com

B

C D

ARCHITECTURE

12222 MERIT DR, SUITE1140DALLAS, TX 75251

972-427-1222 P

4/8

/2019

7:4

1:0

0 P

M

C:\U

se

rs\e

dore

\Do

cum

en

ts\1

8204

BIS

D P

laza

\1820

4 B

I SD

Pla

za-P

LC

Bld

g_A

17.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A8.02

CASEWORK

ELEVATIONS &

DETAILS

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

1/2" = 1'-0"4 RECEPTION DESK RM 101

1/2" = 1'-0"10 REGISTRATION DESK RM 103

1/2" = 1'-0"11 KITCHENETTE ISLAND RM 123

3/4" = 1'-0"5 HARDWARE CHARGING COUNTER

1" = 1'-0"6 DISPLAY CASE SECTION

1" = 1'-0"17 BABY CHANGING STATION DETAIL

1" = 1'-0"14 VANITY COUNTER DETAIL

3/4" = 1'-0"23 CABINET SECTION

3/4" = 1'-0"21 CABINET SECTION

1/4" = 1'-0"2 TEACHING AND LEARNING EAST ELEVATION

1/4" = 1'-0"9 TEACHING AND LEARNING NORTH ELEVATION

No. Description Date3 ADDENDUM #03 04/09/2019

KEY NOTE LEGEND

KEYNOTE DESCRIPTION

08.01 DOOR & FRAME AS SCHED. (TYP)

08.02 FRAMED GLAZING SYSTEM & GLASS AS SCHED.

09.08 PT-6 PAINT - INKY BLUE

09.09 PT-5 PAINT - FADED FLAXFLOWER

09.12 PT- 2 PAINT - DRIFT OF MIST

09.15 PL-1 LAMINATE - FROSTY WHITE

09.17 PL-3 LAMINATE - PHANTOM COCOA

10.19 VERTICAL MARKER BOARD 4'X7'

3

3

Addendum 03 - Page 26 of 33

Page 27: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

TV

TV

TV

TV

GENERAL CEILING PLAN NOTES

1. REFER TO AND COORD. WITH ROOM FINISH SCHEDULES FOR SPECIFIC CEILING TYPES.

2. ALL SCHEDULED CEILING HEIGHTS ARE FROM THE MAIN FLOOR LEVEL WITHIN THE ROOM AND OR SPACE, AND ARE NOT FROM AN ELEVATED FLOOR LEVEL, AND ARE NOT FROM A RECESSED FLOOR LEVEL.

3. NO FIRE SPRINKLER HEADS ARE SHOWN ON ARCH. CEILING PLANS. ALL SPRINKLER HEADS SHALL BE CENTERED WITHIN CEILING TILES U.N.O.

4. ONLY CEILING MOUNTED FIXTURES AND EQUIP. IS SHOWN ON ARCH. CEILING PLANS. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED FIXTURES. REFER TO MEPT DOCUMENTS FOR ADDITIONAL INFORMATION CONCERNING CEILING MOUNTED FIXTURES AND OR WALL MOUNTED FIXTURES.

5. CEILING MOUNTED LIGHT FIXTURES ARE SHOWN FOR LOCATION PURPOSES ONLY. COORD. WITH ELEC. DOCUMENTS FOR LIGHT FIXTURE DESIGNATIONS.

6. CEILING MOUNTED LIGHT FIXTURES WITHIN FIRE RATED CEILING ASSEMBLIES SHALL HAVE LIGHT FIXTURE PROTECTION AND BE TENTED OR OTHERWISE FIRE RATED TO MATCH CEILING ASSEMBLY FIRE RATING.

7. VERIFY LOCATIONS OF ALL CEILING ACCESS PANELS WITH MEPT DOCUMENTS. COORD. LOCATIONS OF CEILING ACCESS PANELS WITH ARCH. PRIOR TO INSTALLATION. CEILING ACCESS PANEL FIRE RATINGS SHALL MATCH CEILING ASSEMBLY FIRE RATINGS.

8. REFER TO WALL SECTIONS FOR WALL-CEILING INTERFACE

ARCH CEILING-LEGEND

APC TYPE A - 2' x 2' ACOUSTIC PANEL RE: FINISH SCHEDULE

APC TYPE A#2 - 2' x 2' ACOUSTIC PANELRE: FINISH SCHEDULE

GWB - GYPSUM BOARD RE: FINISH SCHEDULE

APC TYPE C # - 2' x 2' ACOUSTIC PANEL MOISTURE RESISTANTRE: FINISH SCHEDULE

SPW - WOOD CEILING SYSTEM RE: FINISH SCHEDULE

TYPE K - RECESSED DOWNLIGHTRE: ELECTRICAL

TYPE L1 - PENDANT LIGHTRE: ELECTRICAL

TYPE L2 - PENDANT LIGHTRE: ELECTRICAL

TYPE A - 4' RECECSSED LIGHTING RE: ELECTRICAL

TYPE D - 8' PENDANT LIGHTING RE: ELECTRICAL

TYPE E - PRUDENTIAL LIGHTING RE: ELECTRICAL

DROP DOWN PROJECTOR RE: ELECTRICAL

16'-0" - SUSPENDED PROJECTOR SCREEN RE: ELECTRICAL

CEILING HEIGHTX'-X''

SPW - PL WOOD CLOUD CEILING SYSTEM RE: FINISH SCHEDULE

TYPE A - 6' RECECSSED LIGHTING RE: ELECTRICAL

TYPE A - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE H - COVE LIGHTING RE: ELECTRICAL

TYPE F1 - COVE LIGHTING RE: ELECTRICAL

TYPE F2 - COVE LIGHTING RE: ELECTRICAL

TYPE B - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE C - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE M - EXTERIOR LIGHTING WALL PACK RE: ELECTRICAL

CORRIDOR

102

PROFESSIONAL

LEARNING

CENTER

116

CLASSROOM

OF THE

FUTURE

110A

TRAINING

ROOM

111A

TRAINING

ROOM

112A

TRAINING

ROOM

114

FUTURE

EXPANSION

167

MEN'S RR

130

WOMEN'S RR

131

STORAGE

125

WOMEN'S RR

118

MEN'S RR

119

WOMEN'S RR

158MEN'S RR

157

STORAGE

120

KITCHENETTE

123

FUTURE

EXPANSION

166FUTURE

EXPANSION

176

FUTURE

EXPANSION

171

VEST

164

VEST

156

TEACHING AND

LEARNING

133

DIRECTOR

150

CONFERENCE

ROOM

152

STORAGE

162

ADMIN ASSIST

OFFICE

149

MDF

161ELEC

160

RECEPTION

WAITING

148

COORD. ELEM.

SOCIAL

STUDIES

147

COORD.

SECOND

SOCIAL

STUDIES

146

COORD.

SECOND

SCIENCE

145

COORD. ELEM.

SCIENCE

144 COORD

SECOND MATH

143

COORD. ELEM.

MATH

142 COORD

SECOND ELAR

141

COORD. ELEM.

ELAR

140

WORK ROOM

154

PROGRAM

COORD.

136

ONLINE

LEARNING

SPECIALIST

134

ELEC

135LITERACY

SPECIALIST

153

PANEL

STORAGE

121

PANEL

STORAGE

122

PANEL

STORAGE

124

STORAGE

127

STORAGE

128

STORAGE

104

AV STORAGE

105A

REGISTRATION

DESK

103FIRE RISER

107A

CORRIDOR

138

COORD.

137

COORD.

139

ELEC

175

ELEC

174

ELEC. EXISTING

173

STAIRS

172

STAIRS

169

STORAGE

EXISTING

170

RECEPTION

101

FIRE RISER

177

VEST

113

MECH

168

MECH EXISTING

165

JAN

159

VESTIBULE

100

COLLABORATION

126.1COLLABORATION

126.2

COLLABORATION

106A

COLLABORATION

126.3

VESTIBULE

108A

COLLABORATION

109A

13' - 0" 13' - 0"

13' - 0"

13' - 6"

13' - 6"

10' - 0"

13' - 0"

11' - 2" 11' - 2" 11' - 2" 11' - 2"

11' - 2"

13' - 0"

9' - 0"

9' - 0"

11' - 2"

11' - 2"

11' - 2"

11' - 2"

11' - 2"

11' - 2"

10' - 0"11' - 2"

11' - 2"

9' - 0"10' - 0"

9' - 0"10' - 0"

11' - 2"

11' - 2"

13' - 0"

13' - 0"

12' - 0"

10' - 0"13' - 0"

10' - 0"

4'-1"

4'-0

"4

'-0"

2'-0

3/4

"

14' - 0"

14' - 0"

14' - 0"

14' - 0"

14' - 0"

14' - 0"

14' - 0"

14' - 0"

9' - 0"

5'-0" 2'-0" 5'-0" 2'-0"

IDF

105B13' - 0"

12' - 0"

12' - 6"

13' - 0"

13' - 0"

10' - 0"

10' - 0"

10' - 0"

10' - 0"

14' - 0"

15' - 0"

15' - 0" 15' - 0"

15' - 0"

15' - 0"

15' - 0" 15' - 0"

15' - 0"

15' - 0"

15' - 0"15' - 0"

15' - 0"

15' - 0"

15' - 0"15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0" 15' - 0"

15' - 0" 15' - 0"

15' - 0"

13' - 0"

10' - 10"

11' - 4"

13' - 0"

13' - 0"

13' - 0"11' - 2"

8' - 6"

10' - 0" 10' - 0"

11' - 2"

8' - 6"

10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"

13' - 0"

13' - 0"

10' - 0"

10' - 0"

10' - 0"

12' - 0"

10' - 0"

12' - 0"

10' - 0"

10' - 0"

10' - 0"

12' - 0"

13' - 0"

13' - 0"

13' - 0"13' - 0"13' - 0"

13' - 0"

13' - 0"

13' - 0"

13' - 0"

13' - 0"

13' - 0"

10' - 0"10' - 0"

9' - 0"

9' - 0"

10' - 0"

10' - 0"

10' - 0"10' - 0"10' - 0"

9' - 0"

9' - 0"

9' - 0"

14' - 0" 14' - 0"

14' - 0"

14'

-6"

6'-2

"

38'-7"

6'-4

"

6'-0

"

16'-4"

2'-0

"3

4'-0

"2

'-0"

6'-0

3/4

"

6'-0 3/4" 2'-0" 32'-9 1/2" 2'-0"

EQ EQ EQ 4'-1"

13' - 0"

10' - 0"

12A10.02

20A10.02

2A10.02

24A10.02 24

A10.0222

A10.02

2A10.02

22A10.02

6A10.02

6A10.02

6A10.02

6A10.02

22A10.02

22A10.02

22A10.02

2A10.02

2A10.02

2A10.02

2A10.02

2A10.02

18A10.02

18A10.02

18A10.02

18A10.02

18A10.02

18A10.02

20A10.02

20A10.02

8A4.01

6A10.02

22A10.02

12A10.02

12A10.02

12A10.02

12A10.02

14A10.02

14A10.02

2'-9"6"

8'-7"6"

2'-9"

16A10.02

16A10.02

1A10.02

16A10.02

16A10.02

16A10.02

5A10.02

6A8.02

TYP 6A8.02

TYP20

A10.02

10A10.02

10A10.02

A10.016

A10.014

A10.0116

A10.0118

4

A7.01

1

A7.01

6A10.02

22A10.02

22A10.02

22A10.02

09.16

09.16

10' - 0"

12' - 0"

12' - 0"

07.01

07.01

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL in2arch.com

B

C D

ARCHITECTURE

12222 MERIT DR, SUITE1140DALLAS, TX 75251

972-427-1222 P

4/8

/2019

7:4

1:1

4 P

M

C:\U

se

rs\e

dore

\Do

cum

en

ts\1

8204

BIS

D P

laza

\1820

4 B

I SD

Pla

za-P

LC

Bld

g_A

17.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A10.00

COMPOSITE RCP

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

3/32" = 1'-0"6 COMPOSITE RCP

No. Description Date3 ADDENDUM #03 04/09/2019

KEY NOTE LEGEND

KEYNOTE DESCRIPTION

07.01 PRE-ENGINEERED ALUMINUM CANOPY

09.16 PL-2 LAMINATE - ROOT

3

3

3

Addendum 03 - Page 27 of 33

Page 28: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

GENERAL CEILING PLAN NOTES

1. REFER TO AND COORD. WITH ROOM FINISH SCHEDULES FOR SPECIFIC CEILING TYPES.

2. ALL SCHEDULED CEILING HEIGHTS ARE FROM THE MAIN FLOOR LEVEL WITHIN THE ROOM AND OR SPACE, AND ARE NOT FROM AN ELEVATED FLOOR LEVEL, AND ARE NOT FROM A RECESSED FLOOR LEVEL.

3. NO FIRE SPRINKLER HEADS ARE SHOWN ON ARCH. CEILING PLANS. ALL SPRINKLER HEADS SHALL BE CENTERED WITHIN CEILING TILES U.N.O.

4. ONLY CEILING MOUNTED FIXTURES AND EQUIP. IS SHOWN ON ARCH. CEILING PLANS. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED FIXTURES. REFER TO MEPT DOCUMENTS FOR ADDITIONAL INFORMATION CONCERNING CEILING MOUNTED FIXTURES AND OR WALL MOUNTED FIXTURES.

5. CEILING MOUNTED LIGHT FIXTURES ARE SHOWN FOR LOCATION PURPOSES ONLY. COORD. WITH ELEC. DOCUMENTS FOR LIGHT FIXTURE DESIGNATIONS.

6. CEILING MOUNTED LIGHT FIXTURES WITHIN FIRE RATED CEILING ASSEMBLIES SHALL HAVE LIGHT FIXTURE PROTECTION AND BE TENTED OR OTHERWISE FIRE RATED TO MATCH CEILING ASSEMBLY FIRE RATING.

7. VERIFY LOCATIONS OF ALL CEILING ACCESS PANELS WITH MEPT DOCUMENTS. COORD. LOCATIONS OF CEILING ACCESS PANELS WITH ARCH. PRIOR TO INSTALLATION. CEILING ACCESS PANEL FIRE RATINGS SHALL MATCH CEILING ASSEMBLY FIRE RATINGS.

8. REFER TO WALL SECTIONS FOR WALL-CEILING INTERFACE

ARCH CEILING-LEGEND

APC TYPE A - 2' x 2' ACOUSTIC PANEL RE: FINISH SCHEDULE

APC TYPE A#2 - 2' x 2' ACOUSTIC PANELRE: FINISH SCHEDULE

GWB - GYPSUM BOARD RE: FINISH SCHEDULE

APC TYPE C # - 2' x 2' ACOUSTIC PANEL MOISTURE RESISTANTRE: FINISH SCHEDULE

SPW - WOOD CEILING SYSTEM RE: FINISH SCHEDULE

TYPE K - RECESSED DOWNLIGHTRE: ELECTRICAL

TYPE L1 - PENDANT LIGHTRE: ELECTRICAL

TYPE L2 - PENDANT LIGHTRE: ELECTRICAL

TYPE A - 4' RECECSSED LIGHTING RE: ELECTRICAL

TYPE D - 8' PENDANT LIGHTING RE: ELECTRICAL

TYPE E - PRUDENTIAL LIGHTING RE: ELECTRICAL

DROP DOWN PROJECTOR RE: ELECTRICAL

16'-0" - SUSPENDED PROJECTOR SCREEN RE: ELECTRICAL

CEILING HEIGHTX'-X''

SPW - PL WOOD CLOUD CEILING SYSTEM RE: FINISH SCHEDULE

TYPE A - 6' RECECSSED LIGHTING RE: ELECTRICAL

TYPE A - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE H - COVE LIGHTING RE: ELECTRICAL

TYPE F1 - COVE LIGHTING RE: ELECTRICAL

TYPE F2 - COVE LIGHTING RE: ELECTRICAL

TYPE B - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE C - 8' RECECSSED LIGHTING RE: ELECTRICAL

TYPE M - EXTERIOR LIGHTING WALL PACK RE: ELECTRICAL

5 6

F

4

A6.02

8' - 6"

24A10.02

6'-0

"

8" 3'-10"

1'-0"

4'-0"

1'-0"

4'-0"

1'-0"

4'-0"

1'-0"

3'-10"8"

1'-0

"

4'-0

"

1'-0

"

13' - 0"

11' - 2"

8' - 6"

10' - 0"

EQ

EQ

EQ EQCOLLABORATION126.1

CORRIDOR126

7 8

E

D

6

A6.01

12

A6.01

15' - 0"

15' - 0"

6"2'-9"

6"14'-2" 6" 2'-9"

6"

6"

2'-9

"6

"9

'-7 3

/4"

6"

2'-9

"6

"

16A10.02

12A10.02

18A10.02

14' - 0"

14' - 0"

14' - 0"

PROFESSIONAL

LEARNING

CENTER

116

11.01

11.02

11.03

D

C

6" 2'-9" 6" 8'-7" 6" 2'-9" 6"

6"

2'-9

"6

"1

1'-8

"6

"2

'-9"

6"

16A10.02

12A10.02

18A10.02

15' - 0"

15' - 0"

14' - 0"

14' - 0"

PROFESSIONAL

LEARNING

CENTER

116

11.0111.02

11.03

3 4

B

9' - 2"

7'-3

"

2'-1

1/4

"

1'-1

"7

'-5"

1'-1

"

10'-2"

9' - 2"

9' - 4"

13' - 0"13' - 0"

1'-1" 8'-0" 1'-1"

9'-7

"

EQ

EQ

1'-1" 8'-0" 1'-1"

6A8.02

TYP 6A8.02

TYP

26A10.02

VESTIBULE100

RECEPTION101

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL in2arch.com

B

C D

ARCHITECTURE

12222 MERIT DR, SUITE1140DALLAS, TX 75251

972-427-1222 P

4/8

/2019

7:4

1:1

9 P

M

C:\U

se

rs\e

dore

\Do

cum

en

ts\1

8204

BIS

D P

laza

\1820

4 B

I SD

Pla

za-P

LC

Bld

g_A

17.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A10.01

ENLARGED RCP

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

1/4" = 1'-0"6 ENLARGED RCP COLLABORATION RM 126.1

1/4" = 1'-0"4 ENLARGED RCP PROFESSIONAL LEARNING CENTER

1/4" = 1'-0"16 ENLARGED RCP PROGESSIONAL LEARNING CENTER

1/4" = 1'-0"18 ENLARGED RCP RECEPTION RM 101

KEY NOTE LEGEND

KEYNOTE DESCRIPTION

11.01 MOTORIZED PROJECTOR LIFT, SCISSOR LIFT SLX, REF. MEPT

11.02 PROJECTOR, REF. MEPT

11.03 MOTORIZED PROJECTION SCREEN, REF. MEPT

3

No. Description Date3 ADDENDUM #03 04/09/2019

Addendum 03 - Page 28 of 33

Page 29: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

6"

2"

SUSP CEILING

5/8" GYP BOARD6

"2

"

CEILING HEIGHT

CONT CORNER BEAD BOTH EDGES, TYP

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

6"

2"

SUSP CEILING

5/8" GYP BOARDCEILING HEIGHT

CEILING HEIGHT

CONT CORNER BEAD BOTH EDGES, TYP

6"

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

5/8" GYP BOARD

CEILING HEIGHT

CONT CORNER BEAD

6"

CEILING HEIGHT

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

CONT SEALANT AND BACKER ROD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

SUSP CEILING

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD BRACE AT 96" OC VERT MAX

MTL DECK

SCREW FASTENERS, TYP

CONT 22 GA MIN GALV MTL PLATE, SPAN TWO RIBS OF DECK MIN WITH SCREW FASTENERS ON EACH SIDE OF STUD

THIS DETAIL IS INTENDED TO SHOW THE STUD FRAMING CONNECTION TO DECK CONDITION AND BRIDGING INFORMATION ONLY AND DOES NOT SHOW OTHER ADDITIONAL INFORMATION, REFER TO PARTITION TYPES AND CEILING DETAILS FOR ALL OTHER MATERIALS, COMPONENTS, AND ASSOCIATED INFORMATION

MIN6"

MTL STUD TO DECK ABOVE, LEAVE 1/2" MIN GAP AT TOP AT CONT DEFLECTION TRACK CONDITIONS, DO NOT ATTACH STUD TO CONT DEFLECTION TRACK

ATTACH ANY BOARD ON EITHER SIDE OF STUD NO CLOSER THAN 6" MIN TO TRACK, REFER TO PARTITION TYPES

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT MTL RUNNER TRACK AT CEILING BULKHEAD FRAMING, DEEP LEG DEFLECTION TRACK AT PARTITIONS TO DECK FRAMING, SCREW ATTACH TO MTL PLATE ABOVE

5/8" GYP BOARD

CEILING HEIGHT

CONT CORNER BEAD

6"

CEILING HEIGHT

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

CONT SEALANT AND BACKER ROD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

SUSP CEILING

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD BRACE AT 96" OC VERT MAX

1'-0" 4'-0" 1'-0"

CEILING HEIGHT

WOOD CLOUD CEILING SYSTEM

2'-2

"6

"

RE: RCP

4 TOTAL, 1/4" DIAMETER STAINLESS STEEL. CONNECT TO CFMF BOTH SIDES

CONTINUOUS 4"X4" HEAVY GUAGE "L" ANGLE

LAMINATE FINISH

COLD FORMED METAL FRAMING

CEILING HEIGHT

SUSP CEILING RE: RCP

CEILING HEIGHT

RE

F.

INT

EL

EV

AT

ION

RE

F.

INT

EL

EV

AT

ION

RE: RCP

CONT SEALANT AND BACKER ROD

CEILING AS SCHED., RE: RCP

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

5/8" GYP BOARD

RE: RCP RE: RCP RE: RCP

3 TOTAL, 1/4" DIAMETER STAINLESS STEEL. CONNECT TO CFMF BOTH SIDES

CEILING AS SCHEDULED. RE: RCP15 BLACK SCREWS PER PANEL. PLACE SCREWS IN BETWEEN SLATS.

2 1/2" MTL STUD 24" O.C. PER MANUFACTURER RECOMMENDATIONS.

CEILING HEIGHT

CEILING AS SCHED., RE: RCP

5/8" GYP BOARD. RE: FINISH SCHEDULE

CEILING HEIGHT

CEILING HEIGHT

RE

F.

INT

. E

LE

VA

TIO

N

RE: RCP

CEILING AS SCHED., RE: RCP

CEILING AS SCHED., RE: RCP

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

4"

6"

THREADED ROD

LIGHT AS SCHEDULED, RE: MEP6"

6"

SUSP CEILING

CEILING HEIGHT

3-1/2" UNFACED BATT INSUL

(2) LAYERS 5/8" GYP BOARD

6" MTL STUD FRAMING AT 16" OC MAX

CONT 6" MTL RUNNER TRACK

WALL ASSEMBLY

2' -

0"

CONT ACOUSTICAL SEALANT AND BACKER ROD

6 5

/8"

5/8" GYP BOARD

CONT MTL RUNNER TRACK

6" MTL STUDS AT 24" OC MAX

CONT CORNER BEAD

CEILING HEIGHT

CONT CORNER BEAD

RE

: R

CP

SUSP CEILING

CONT EDGE TRIM

CEILING HEIGHT

CEILING HEIGHT

CEILING AS SCHEDULED. RE: RCP15 BLACK SCREWS PER PANEL. PLACE SCREWS IN BETWEEN SLATS.

2 1/2" MTL STUD 24" O.C. PER MANUFACTURER RECOMMENDATIONS.

CEILING HEIGHT

SUSP CEILING

PROJECTION SCREEN

SCREEN HOUSING WITH OPERABLE DOOR

THREADED RODS TO STRUCT FRAMING MEMBERS ABOVE (NOT DECK)

CEILING AS SCHED., RE: RCP

CEILING AS SCHED., RE: RCP

3-5/8" MTL. STUD

5/8" GYP. BOARD, PAINT GREY

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

MTL CLIP ANGLE AT EACH STUD

CEILING HEIGHT

CEILING HEIGHT

CEILING HEIGHT

5/8" GYP. BOARD, PAINT GREY

6" 1-5/8" MTL. STUD

LIGHTING FIXTURE, RE: MEP

CEILING AS SCHED., RE: RCP

CEILING AS SCHED., RE: RCP

3-5/8" MTL. STUD

5/8" GYP. BOARD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE,

ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK

WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD,

REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC

VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD

FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD

FRAMING, ATTACH TO EACH CLIP ANGLE

CEILING HEIGHT

CEILING HEIGHT

CEILING HEIGHT

5/8" GYP. BOARD

6"1-5/8" MTL. STUD

LIGHTING FIXTURE, RE: MEP

2"

REF: RCP

6"

RE: RCP

CEILING AS SCHEDULED. RE: RCP15 BLACK SCREWS PER PANEL. PLACE SCREWS IN BETWEEN SLATS.

2 1/2" MTL STUD 24" O.C. PER MANUFACTURER RECOMMENDATIONS.

5/8" GYP BOARD. REF. INT. ELEVATION FOR WALL FINISH

CEILING HEIGHT

CONT CORNER BEAD

CEILING HEIGHT

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

CONT SEALANT AND BACKER ROD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

SUSP CEILING

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

MTL CLIP ANGLE AT EACH STUD

3-5/8" MTL STUD BRACE AT 96" OC VERT MAX

LIGHT AS SCHEDULED, RE: MEP

THREADED ROD

6"

4"

5/8" GYP BOARD

CONT TRACK ASSEMBLY BY OPERABLE WALL MANUF

OPERABLE WALL

MA

X

2"

3-5/8" MTL STUDS AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

MTL CLIP ANGLE AT EACH STUD

3-1/2" UNFACE SOUND ATTENUATION BATTS FULL HEIGHT TO DECK ABOVESTRUCT

STEEL SUPPORT

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

SECURE BATTS TO PREVENT SAGGING

SUSP CEILING

HANGERS BY OPERABLE WALL MANUF

CEILING HEIGHT

6"

RE: RCP

CEILING HEIGHT

CEILING HEIGHT

SUSP CEILING

3-5/8" MTL STUDS AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-1/2" UNFACE SOUND ATTENUATION BATTS FULL HEIGHT TO DECK ABOVE

STRUCT STEEL SUPPORT

CONT TRACK ASSEMBLY BY OPERABLE WALL MANUF

OPERABLE WALL

CONT CFMF L-ANGLE

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

HANGERS BY OPERABLE WALL MANUF

SECURE BATTS TO PREVENT SAGGING

2-1/2" MTL STUDS AT 16" OC MAX

CONT CORNER BEAD

6"

RE

: R

CP

SUSP CEILING

CONT EDGE TRIM

CEILING HEIGHT

CEILING HEIGHT

5/8" GYP BOARD

3 5/8" MTL STUD @ 24" O.C.

CEILING HEIGHT

CEILING AS SCHED., RE: RCP

4"

LIGHT AS SCHEDULED, RE: MEP

6"

SUSP CEILING

5/8" GYP BOARD

CONT CORNER BEAD BOTH EDGES, TYP

3-5/8" MTL STUD BRACE TO STRUCT

ABOVE AT 48" OC MAX

CEILING HEIGHT

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL in2arch.com

B

C D

ARCHITECTURE

12222 MERIT DR, SUITE1140DALLAS, TX 75251

972-427-1222 P

4/8

/2019

7:4

1:2

3 P

M

C:\U

se

rs\e

dore

\Do

cum

en

ts\1

8204

BIS

D P

laza

\1820

4 B

I SD

Pla

za-P

LC

Bld

g_A

17.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A10.02

CEILING DETAIL

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

1 1/2" = 1'-0"2 CEILING DETAIL

1 1/2" = 1'-0"1 CEILING DETAIL

1 1/2" = 1'-0"6 CEILING DETAIL

1 1/2" = 1'-0"7 TYP BULKHEAD STUD FRAMING TO DECK

1" = 1'-0"24 CEILING DETAIL

1 1/2" = 1'-0"26 CEILING DETAIL

1" = 1'-0"5 CEILING DETAIL

1 1/2" = 1'-0"8 DOUBLE CEILING DETAIL

1 1/2" = 1'-0"9 CEILING EDGE DETAIL

1 1/2" = 1'-0"10 CEILING EDGE DETAIL

1 1/2" = 1'-0"12 RECESSED PROJECTION SCREEN

1" = 1'-0"14 CEILING DETAIL

1" = 1'-0"16 CEILING DETAIL

1 1/2" = 1'-0"22 CEILING DETAIL

1 1/2" = 1'-0"18 CEILING DETAIL OPERABLE WALL

1 1/2" = 1'-0"20 CEILING DETAIL OPERABLE WALL

1 1/2" = 1'-0"11 CEILING EDGE DETAIL

1 1/2" = 1'-0"3 CEILING DETAIL

2

2

2

No. Description Date2 ADDENDUM #02 04/04/2019

3 ADDENDUM #03 04/09/2019

3

3

Addendum 03 - Page 29 of 33

Page 30: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

LIGHTING CONTROLS DEVICE LEGEND (ACUITYBRANDS)

DO2

DO6

DP1

DP2

GX1

IO1

NI1

OS11

OS3

OS5

OS6

PO2

PP2

PS2

PT1

S1

S10

S2

S8

SC2

SO5

SW1

SW2

SW4

TS1

NBRG 8 KITBridge, Kit

DO2NWSX PDT LV DX XXWallSwitch Sensor, Passive Dual Technology,Low Voltage, Occupancy controlleddimming without dimming output;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

DO6WSX PDT D SA XXWall SwitchSensor, Passive Dual Technology,Occupancy Controlled Dimming, Vacancy(default) or Auto-On; COLOR/FINISH TOBE SELECTED PRIOR TO ORDERING

DP1NPP16 D EFPPower/RelayPack, Occupancy Controlled Dimming,External Fault Protection

DP2NPP16 D EFP SAPower/RelayPack, Occupancy Controlled Dimming,External Fault Protection, Vacancy(default) or Auto-On

GX1NPOD GFX XXLow VoltageWallpod, Graphic Touchscreen;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

IO1FCS AVI 120/277 XXFRESCODEVICE, AUDIO VISUAL INTERFACE,120/227V

NI1NIO X KITnLight Device,External Touch Panel Interface, Kit

OS11NCM PDT 9Low VoltageCeiling Mount Sensor, Passive DualTechnology, Small Motion / StandardRange 360ᄚ Lens

OS3NWV 16 KITLow VoltageCorner Mount Sensor, Kit

OS5NCM 10Low Voltage CeilingMount Sensor, Large Motion / ExtendedRange 360ᄚ Lens

OS6NCM PDT 10Low VoltageCeiling Mount Sensor, Passive DualTechnology, Large Motion / ExtendedRange 360ᄚ Lens

PO2NCM PDT 10 ADCXLowVoltage Ceiling Mount Sensor, PassiveDual Technology, Large Motion / ExtendedRange 360ᄚ Lens, Photocontrol w/ AutoDimming; No Wires

PP2NPP16 EFP SAPower/RelayPack, External Fault Protection, Vacancy(default) or Auto-On

PS2FCS PS10Power Supply, 10watts

PT1PTS 60 XXPreset Timer Switch,60 Minute Max; ; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

S1NPODM XXLow VoltagePush-Button Wallpod; COLOR/FINISH TOBE SELECTED PRIOR TO ORDERING

S10NPODM 4S DX XXLow VoltagePush-Button Wallpod, 4 scene control,Raise/Lower Dimming Without Wires;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

S2NPODM DX XXLow VoltagePush-Button Wallpod, Occupancycontrolled dimming without dimmingoutput; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

S8NPODM 2S DX XXLow VoltagePush-Button Wallpod, Occupancycontrolled dimming without dimmingoutput; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

SC2NECY MVOLT BAC ENCnLightEclypse, 120-277 VAC, BACnet, 14 1/4"Hx 14 1/4"W x 4"D metal enclosure forECLYPSE EnergySyte or nLight ECLYPSE.

SO5WSX SA XXWall SwitchSensor, Vacancy (default) or Auto-On;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

SW1NPODM 1SB XXLow VoltagePush-Button Wallpod

SW2NPOD KEY XXLow VoltageWallpod, Digital keyswitch

SW4FCS RB 8B XXFRESCODEVICE, Architectural push button wallstation, 8 BUTTONS

TS1FCS 7TSN XXFRESCODEVICE, 7" TOUCH SCREEN

NEUTRALLINE (120-277V~)

GROUND

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLACKRED

WH

ITE

BLK

/OR

G

N H

FCS PS10

BLK/ORG-

120V/ 277V

POWER SUPPLYH

N

SEE WIRING DIAGRAM FORINTERNAL AND EXTERNALWIRING DETAILSFRESCO

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

24 VDCCOMMONINPUT 1INPUT 2

NECY MVOLT BAC ENC

SC2

NBRG 8 KITSPARESPARESPARE

[MBRG]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-A]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-B]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-C]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5SPARESPARE

[BRG-D]

PS2

FCS PS10

FCS PS10

FCS PS10

PS2

PS2

A4 A4 A4

A4

A4A4A4

A4 A4 A4 A4

A4

A4

FCS 7TSN XX

TS1

FCS AVI 120/277 XX

IO1

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

FCS RB 8B XX

SW4

24VDC

POWER SUPPLY

LINE

120/277VAC

(CLASS I)

24VDC (CLASS II)+ RED 24V DC

- COMMON

POWER SUPPLY + 24 VDC RED

POWER SUPPLY COMMON

WALLSTATION DATA +

WALLSTATION DATA -

WALLSTATION DATA COMMON

TERMINATE DMX

SHIELD TO EARTH

GROUND ONLY IN

STATION BACKBOX

FRESCO WALLSTATION NETWORK SYA CABLEA4

FRESCO POWER

SUPPLY DETAIL

POWER SUPPLY + 24 VDC RED

POWER SUPPLY COMMON

WALLSTATION DATA +

WALLSTATION DATA -

WALLSTATION SHIELD

DMX COMMON

DMX DATA -

DMX DATA +

DMX SHIELD

TERMINATE DMX

SHIELD TO EARTH

GROUND ONLY IN

STATION BACKBOX

TERMINATE

WALLSTATION SHIELD TO

EARTH GROUND ONLY IN

STATION BACKBOX

FRESCO WALLSTATION NETWORK SYA CABLEA4

nLIGHT (IN/OUT)

FRESCO CONTROL NETWORK

(FCN) NETWORK TERMINATION

ETHERNET

DMX NETWORK

TERMINATION

FRESCO TERMINATION DETAIL

FRESCO NETWORK DETACHABLE

PIGTAIL HARNESS

DMX/RDM NETWORK

DETACHABLE PIGTAIL HARNESS

WHITEYELLOW BLACK

YELLOW W/ B

LACK STRIPE

WHITE W/ BLACK STRIPE

RE

DBLA

CK

BLUE

HN

WH

TnPP16 D EFP

VIOLETGRAY

GRN

BLK

/OR

N

RJ45

RJ45

LUMINAIRE

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

CC

B

B

B B

A

A

A

B

C

WIRE LEGEND

0-10 VDC

LINE VOLTAGE

CAT 5-E (CLASS 2)

BLK- 120V/ ORN- 277V

0-10V DIMMING

(2)RJ45

PORTS:

+40mA

EACH TO ADDITIONAL

LUMINAIRES ON SAME

ZONE

RE

D

WH

TnPP16 EFP

GRN

BLK

/OR

N

RJ45

RJ45

BLUE

HN

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

A

B

WIRE LEGEND

LINE VOLTAGE

CAT 5-E (CLASS 2)

B

B

B B

A

A

LUMINAIRE

BLK- 120V/ ORN- 277V

SWITCHING ONLY

(2)RJ45

PORTS:

+40mA

EACH TO ADDITIONAL

LUMINAIRES ON SAME

ZONE

RE

D

RS232 CONNECTION TOAV RACK. COORDINATEWITH AV CONTRACTOR

2LIGHTING CONTROL DIAGRAMS (ACUITY BRANDS)NOT TO SCALE

1MULTIPURPOSE LIGHTING CONTROLS DIAGRAMNOT TO SCALE

4TYPICAL WIRING DIAGRAM NPP16-EFPNOT TO SCALE

3TYPICAL WIRING DIAGRAM - NPP16-D-EFPNOT TO SCALE

5MULTIPURPOSE TOUCHSCREEN DETAIL (FRESCO)NOT TO SCALE

LIGHTING FIXTURE NOTES

KEY TO NOTE PREFIXES: "G" NOTES ARE "GENERAL" LIGHTING NOTES

THAT APPLY TO THE ENTIRE PROJECT. "S" NOTES ARE "SCHEDULE"

NOTES THAT APPLY TO SPECIFIC LUMINAIRES.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS, ELEVATIONS,

SECTIONS, AND DETAILS FOR THE EXACT LOCATION OF ALL

LUMINAIRES. ARCHITECTURAL PLANS SHALL GOVERN FOR LOCATION

AND LAYOUT. IF ARCHITECTURAL AND ELECTRICAL DRAWINGS

CONFLICT IN EXACT COUNT OR FIXTURE TYPE, PROVIDE THE

GREATER QUANTITY OR COST TYPE UNLESS OTHERWISE

INSTRUCTED.

REFER TO DIVISION 26 ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

LUMINAIRE AND ELECTRICAL REQUIREMENTS (LENS, AIR HANDLING

CHARACTERISTICS, T-BAR CLIPS, BALLAST, LAMPS, TIME FRAME FOR

SUBMITTAL OF SUBSTITUTE LIGHT FIXTURES FOR PRIOR APPROVAL,

ETC.).

FOR EACH SCHEDULED LUMINAIRE, PROVIDE ALL REQUIRED

APPURTENANCES FOR INSTALLATION IN APPLICABLE STRUCTURE OR

SPECIFIED ARCHITECTURAL CEILING. ALL LUMINAIRES SHALL HAVE

THE APPROPRIATE NEMA TYPE FRAME THAT IS COMPATIBLE WITH

THE CEILING SYSTEM SPECIFIED BY THE ARCHITECT. ELECTRICAL

DRAWINGS DO NOT INDICATE CEILING TYPES, CONTRACTOR SHALL

REFER TO ARCHITECTURAL PLANS TO DETERMINE CEILING TYPE

(GRID, FLANGE, SPLINE, SCREW SLOT, ETC.) AND PROVIDE

APPROPRIATE FRAME.

EXIT SIGNS AND OTHER LUMINAIRES SHALL NOT BE SUPPORTED BY

CEILING TILE. PROVIDE MOUNTING FRAME OR HANGERS TO

SECURELY FASTEN IN PLACE ALL LUMINAIRES MOUNTED IN CEILING

TILE. FRAMING MEMBERS OF A SUSPENDED CEILING SYSTEM MAY BE

USED WHERE DESIGNED FOR THE PURPOSE AND INSTALLED PER NEC

410-16(C).

WHERE A SURFACE-MOUNTED LUMINAIRE CONTAINING A BALLAST IS

TO BE INSTALLED ON COMBUSTIBLE LOW-DENSITY CELLULOSE

FIBERBOARD, IT SHALL BE LISTED FOR THIS CONDITION OR SHALL BE

SPACED NOT LESS THAN 1 1/2 INCHES FROM THE SURFACE OF THE

FIBERBOARD (NEC 410-76(B)).

REQUEST FOR SUBSTITUTION SHALL FOLLOW SPECIFIED

PROCEDURES AND SHALL INCLUDE A WORKING SAMPLE SUITABLE

FOR TABLE TOP EXAMINATION.

REPLACE EXISTING EXTERIOR WALLPACK LIGHTS WITH NEW LED

FIXTURE USING ONE-FOR-ONE REPLACEMENT, REFER TO

ARCHITECTURAL LIGHTING TYPE 'M'. REUSE EXISTING CIRCUITING

AND CONTROL AS APPLICABLE,

UNLESS OTHERWISE NOTED, MOUNT EXIT SIGN DIRECTLY ABOVE

EGRESS DOOR (MAXIMUM 24" ABOVE DOOR), PROVIDE WALL MOUNT

EXIT SIGNS IN HIGH CEILING AREAS, PROVIDE WINDOW MULLION

MOUNTING WITH CONCEALED WIRING WHERE REQUIRED.

COORDINATE EXACT ELEVATION WITH ARCHITECT PRIOR TO

ROUGH-IN.

G1.

G2.

G3.

G4.

G5.

G6.

G8.

G7.

S1.

LICENSED

PRO

FESSIONAL ENGIN

EER

STATE OF TEXAS

F-18672

LEAF ENGINEERS

DONALD C. RICHARDS

61525

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL NAME

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

ADDRESSADDRESS

012-345-6789 P 012-345-6789 F

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECTURAL NAME

B

C D

ARCHITECTURE

ADDRESSADDRESS

012-345-6789 P 012-345-6789 F

03/08/2019

4/9

/2019

10:4

0:5

7 A

M

C:\U

se

rs\s

wa

y\D

ocum

ents

\18204

BIS

D P

laza

-PLC

Ele

c R

17_sw

ay.r

vt

BIS

D P

LA

ZA

PL

C B

UIL

DIN

G

ISS

UE

FO

R C

ON

ST

RU

CT

ION

E0.02

LIGHTING FIXTURE

SCHEDULE

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6351

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

LIGHTING FIXTURE SCHEDULETYPE DESCRIPTION LAMP MANUFACTURER # MODELA 4" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPB 4" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPC 3" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL2L-LOPD SUSPENDED LINEAR LED FLUXWERX # PF1E SUSPENDED PENDANT SQUARE LED PRUDENTIAL # BSQEM RECESSED RETRACTABLE LED CONCEALITE # 5000

EMERGENCY LIGHTEX EXTERIOR EGRESS LED LITHONIA # AFN-COLOR-EXT

EMEREGENCY LIGHTF RECESSED COVE LED ECOSENSE # SCDG RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPH RECESSED LINEAR SLOT LED FINELITE # HP-WSJ UNDER CABINET LIGHT LED FEELUX # TUN-35KK RECESSED DOWNLIGHT LED GOTHAM # EVO-SQL1 DECORATIVE PENDANT LED LOUIS-POULSON # PATERA-277V-LEDL2 DECORATIVE PENDANT LED OCL # ROYALE-LED1-30K-UNV-DM1

No. Description Date3 ADDENDUM #03 04/09/2019

3

Addendum 03 - Page 30 of 33

Page 31: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

TV

TV

TV

TV

TVT

V

MSMS

MS

MS

MS

MS

MS

MS

MS

TV

GENERAL NOTES

1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS TAKE PRECEDENCE, CONTACT ARCH IF CLARIFICATION IS NECESSARY IN ORDER TO DETERMINE THE INTENT OF THE CONTRACT DOCUMENTS

2. DRAWINGS NOTED AS "N.T.S" OR "NTS" ARE NOT TO SCALE3. ALL DIMENSIONS ARE TO STRUCTURAL COLUMN LINES OR THE SURFACE OF

PARTITION ASSEMBLY U.N.O.4. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE

COMMENCING WORK. NOTIFY ARCH. OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH AFFECTED WORK

5. NOTES OR DIMENSIONS NOTED AS "TYPICAL" OR "TYP." OR "TYP" SHALL APPLY TO CONDITIONS THAT ARE THE SAME OR SIMILAR

6. DIMENSIONS NOTED AS "FIELD VERIFY" OR "V.I.F." OR "VIF" SHALL BE MEASURED AND CONFIRMED AT THE PROJECT SITE BY THE CONTRACTOR AND REVIEWED WITH THE ARCH. BEFORE INCORPORATING INTO THE WORK

7. DIMENSIONS NOTED AS "CLEAR" OR "CLEAR INSIDE" REQUIRE SPECIFIC COORDINATION AMONG DISCIPLINES AND OR MANUFACTURERS

8. REFER TO PARTITION TYPES ON A7.00 SERIES SHEETS9. ALL INTERIOR PARTITIONS THIS SHEET, EXCEPT FOR FURR-OUT PARTITIONS,

SHALL BE PARTITION TYPE ___S6____ U.N.O.10. ALL INTERIOR FURR-OUT PARTITIONS THIS SHEET SHALL BE PARTITION TYPE

____F4___ U.N.O.11. ALIGN FINISHED FACE OF WALLS WHERE WALL PARTITIONS OF DIFFERING

THICKNESS ABUT AND OR ADJOIN IN THE SAME PLANE12. PROVIDE AND INSTALL CONT. REVEAL TRIM AT JOINT WHERE GYPSUM BOARD

WALL PARTITIONS ABUT AND OR ADJOIN MASONRY WALL PARTITIONS IN THE SAME PLANE

13. ALL INTERIOR CMU OUTSIDE CORNERS SHALL HAVE BULLNOSE U.N.O.14. ALL DOORS SHALL BE SET 6 INCHES OFF THE ADJACENT PERPENDICULAR

WALL ON THE HINGE SIDE OF THE DOOR U.N.O., NOTIFY ARCH. OF ANY DOOR-RELATED CONFLICTS, INCLUDING BUT NOT LIMITED TO CONFLICTS CONCERNING ACCESSIBILITY STANDARDS

15. ALL DOOR THRESHOLDS AT ALL EXTERIOR DOORS SHALL BE SET IN FULL BED OF SEALANT

16. COORD. ALL ROOF DRAIN LEADER LOCATIONS WITH FLOOR PLAN PRIOR TO FLOOR SLAB CONSTRUCTION

17. ALL FLOOR SLOPES TO FLOOR DRAINS SHALL NOT EXCEED 1:4818. PROVIDE AND INSTALL SELF-LEVELING UNDERLAYMENT WHERE UNEVEN

FLOOR SLAB EXISTS PRIOR TO INSTALLATION OF FLOOR FINISHES19. COORD. HOUSEKEEPING PAD LOCATIONS AND DIMENSIONS WITH EQUIPMENT

TO BE INSTALLED20. ALL FLOOR FINISH CHANGES SHALL OCCUR AT THE CENTERLINE OF DOORS

U.N.O.21. ALL FLOOR FINISH MATERIAL CHANGES SHALL HAVE REDUCER STRIPS22. ALL REQUIRED ACCESSIBLE CLEARANCES FOR ALL ITEMS, INCLUDING BUT NOT

LIMITED TO ALL COUNTER TOPS, ALL PLUMBING FIXTURES, ALL DRINKING FOUNTAINS, ALL ELECTRIC WATER COOLERS, ALL LAVATORIES, ALL URINALS, ALL TOILETS SHALL BE STRICTLY ENFORCED

23. APPLY BITUMINOUS COATING TO ALL CONCEALED STRUCTURAL STEEL MEMBERS AT ALL EXTERIOR CANOPY LOCATIONS

24. REFER TO OTHER DISCIPLINE DOCUMENTS FOR ADDITIONAL SCOPE OF WORK25. PREP ALL APPLICABLE SURFACES TO RECEIVE OPEN CELL SPRAY INSULATION

TO ACHIVE R15 MIN., PER SPRAY INSULATION MANUFACTURER RECOMMENDATIONS

26. PATCH AND PAINT THE EXISTING PARTITIONS TO REMAIN PER ROOM FINISH SCHEDULE

ALI

GN

11'-3" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 24'-6 1/4"

18'-1 3/4"5'-0 1/4"

12'-2" 19'-7" 6'-9" 23'-6 1/2" 8'-0" 8'-9" 26'-2 1/4" 14'-6"

15'-0"7'-10" 2'-1" 28'-2" 2'-1" 8'-11"

5'-1

0 1

/2"

6'-1

0"

4'-2

"7

'-9 1

/4"

5'-1

0 1

/2"

12'

-7"

12'

-7"

12'

-7"

12'

-7"

9'-7

3/4

"5

'-2"

LARGE

WAREHOUSE

166

TRANSITION

SPECIALIST

150

INTINERANT

SVCS & MGMT

SYSTEM

151

SUPER

RDSPD

152COORD.

156COORD.

154COORD.

155

ACCESS.

COORD.

157

ADMIN TO

DIRECTOR

162

DIRECTOR163

CONFERENCE

ROOM

164

SPECIAL

EDUCATION

165

WAITING

AREA

159

TESTING

AREA

158

DIAGNOSTICIAN

OFFICE

146

TESTING

STORAGE

141

DIAGNOSTICIAN

OFFICE

145

DIAGNOSTICIAN

OFFICE

144

FILE

STORAGE

132

WORK ROOM142

SUPER.

AUTISM /

BEHAVIOR

SVCS

153

WOMEN'S

RESTROOM

136

MEN'S

RESTROOM

135

CUST.134

TEAM

MEETING

ROOM

143

CONFIGURATION

LAB

131

TECHNOLOGY

PURCHASE

OFFICE

128

CONFERENCE

ROOM

139

CORRIDOR133

FIRE RISER167

T128B

T149.2B

T131B

T166.2B

T166.1B

T156B

T155B

T154BT153

B

T152B

T151B

T144B

T141B

A6.01

10

6

A6.02

B B

S6S6

F4

S6

S6

S6

S6

S6

S6

S6

S6

S6

S6

F4

F4

F4

S6

F4

S6S6

S6

S6

S6

S6S6S6S6

S6

S6

S6

S6

S6

S8

S6

S6

S6S6S6S6S6S6S6S6

S6

S6

BT128

T130.1B

T130.2B VESTIBULE

130

CORRIDOR129

T166.3

VESTIBULE149

DIAGNOSTICIAN

OFFICE

147

F4F4 F4

BT143

T143BB

T144

T145B

BT145

BT146

T146B

BT147

T147B

T149.1B

BT151

BT152

BT153

BT155

BT156

BT154

BT157

BT159.1

T157B

BT161.1

BT162.1

T161B

T162B

BT164

T164B

TEAM

MEETING

ROOM

161

A8.02

4

10'

-7"

21'

-0"

12'

-0"

6'-7

1/2

"1

4'-7

1/4

"

F4

F4

9'-7" 2'-0" 13'-3" 31'-6 1/2"

A5.012

27A8.01

F4

F4

F4

CO

RR

IDO

R1

40

CORRIDOR148

RECEPTION160

SPECIAL

EDUCATION

165A

SPECIAL

EDUCATION

165B

SPECIAL

EDUCATION

165C

SPECIAL

EDUCATION

165D

SPECIAL

EDUCATION

165E

SPECIAL

EDUCATION

165F

T159.2B

BT158.2

7'-10" 10'-0" 6'-3 1/4"

BT158.1

BT159.3

BT159.2

T166.4B

T135B

T134B

T136B

ELEC168

T168B

T132B

T133B

T163.2B

T163.1B

T138.3B

T150B

BT150

T158.1B

T159.1B

T158.2B

A8.01

21

18

20

S6

S6

A2.0220

AT138.1

BT163

BT161.2

F4F4 F4F4 F4F4F4F4

18

A6.02

A2.0221

T139.1B

T139B

TA-8

4

A7.01

A8.01

30

A8.02

6

5

F4

11A8.02

TYP

T142B

CYLINDERS

ROOM

169

T169B

24

23

F4

S5

S5

A8.02

2

11.04

11.04

11.04

11.04

11.04

11.04

11.04

10.1310.13

10.13

S6

10.20

10.13

10.21

10.2110.21

BT142

F4

F4

F4

F4 F4

F4

13

'-11

1/2

"6

'-8 1

/4"

S6

6'-7

"9

'-8 1

/2"

12'

-0"

10.23

A2.0424

4

A7.01

Sim

2

A7.01

Sim

ALIGN

09.12

11.07

A8.02

26

22

20

28

1'-6"

OPEN CELL SPRAY INSULATION TO ACHIVE R15 MINIMUM

5/8" GYP BD

STRUCT. STL & STUB ENDPLATE TO BE FLUSH W/ OUTSIDE FINISH OF WALL, RE: STRUCT.

CANOPY BEAM PER MANUFACTURER

STRUCT. STL & STUB ENDPLATE TO BE FLUSH W/ OUTSIDE FINISH OF WALL, RE: STRUCT.

HOLLOW STRUCTURAL STEEL COLUMN TO STRUCTURAL DECK ABOVE., RE: STRUCTURAL

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

MTL CLIP ANGLE AT EACH STUD

HOLLOW STRUCTURAL STEEL COLUMN TO STRUCTURAL DECK ABOVE., RE: STRUCTURAL

BRICK/STONE VENEER RE: ELEVATIONS

EXISTING CONDITION. V.I.F.

BRICK/STONE VENEER BEYOND. RE: ELEVATIONS

HOLLOW STRUCTURAL STEEL COLUMN TO STRUCTURAL DECK ABOVE., RE: STRUCTURAL

CANOPY BEAM PER MANUFACTURER

STRUCT. STL & STUB ENDPLATE TO BE FLUSH W/ OUTSIDE FINISH OF WALL, RE: STRUCT.

OPEN CELL SPRAY INSULATION TO ACHIVE R15 MIN

EXISTING CONDITION. V.I.F.

STUCCO. RE: ELEVATIONS

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

SUSP CEILING

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

MTL CLIP ANGLE AT EACH STUD

ALIGN NEW STOREFRONT EXTERIOR FACE WITH EXISTING

CONT SEALANT AND BACKER ROD BOTH SIDES

SHIM

FRAME AS SCHEDULED

J

9

05.0305.02

05.0305.03

09.47

08.02

08.02

09.46

09.46

09.46

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTH

KEY PLAN TRUE NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECT in2arch.com

B

ARCHITECTURE

12222 Merit Drive, Suite 1140Dallas, Texas 75251

972-427-1222 P

4/9

/2019

11:5

3:5

3 A

M

C:\U

se

rs\e

dore

\Docum

ents

\18

204

BIS

D P

laza-T

echno

log

y B

ldg

_A

17_e

dore

.rvt

BIS

D P

LA

ZA

TE

CH

NO

LO

GY

SE

RV

ICE

S

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A2.04

FIRST FLOOR

AREA B

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6321

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

1/8" = 1'-0"6 AREA PLAN B

No. Description Date2 ADDENDUM #02 04/04/2019

3 ADDENDUM #03 04/09/2019

KEY NOTE LEGEND

KEYNOTE DESCRIPTION

05.02 HSS COLUMN FOR THE PRE-ENGENEERED ALUMINUM CANOPY. REF STRUCT

05.03 LIGHT GA CFMF AS PER MANUFACTURER RECOMMENDATIONS

08.02 FRAMED GLAZING SYSTEM & GLASS AS SCHED.

09.12 PT- 2 PAINT - DRIFT OF MIST

09.46 R SERIES 1/2" X 1/2" REVEAL LOCKING INSERT

09.47 FRY REGLET COLUMN COVER

10.13 MARKER BOARD 8'X4'

10.20 NEW MOP SINK, REF. MEP

10.21 NEW INDUSTRIAL METAL SHELVING

10.23 MOBILE HIGH-DENSITY STORAGE SHELVING, REF. SPECS

11.04 TELEVISION, REF. MEPT

11.07 AIR CURTAIN, REF. MEPT

1" = 1'-0"21 ALUM CANOPY @ MASONRY

1" = 1'-0"23 ALUM CANOPY DETAIL @ CURTAIN WALL

1 1/2" = 1'-0"24 COLUMN COVER

2

3

3

Addendum 03 - Page 31 of 33

Page 32: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

COUNTER TOP AS SPEC'D

BASE AS SCHED.

PLAS. LAM. ON 3/4" PLYWOOD DRAWER/ DOOR FRONT w/ HANDLE AS SPEC'D w/ 1/4" GAP BETWEEN

DRAWER AND DOOR FRONTS, TYP.

ADJUSTABLE PLAS. LAM. SHELF

K&V #255 STANDARDS W/ #256 STEEL SUPPORTS

1/4" PLYWOOD BACK LET INTO TOP AND BOTTOMPANELS OF CABINET

PLAS. LAM ON 3/4" PLYWOOD

6"

1'-0

"

EQ

EQ

2'-8"

RE

F. E

LE

V.

RE

F. E

LE

V.

RE

F. E

LE

V.

3'-0"

SUSP CEILING AS SCHED. RE: RCP

PLAS. LAM ON 5/8" GYP BOARD

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD RE: ELEVATION FOR FINISH

TILE, RE: ELEVATION FOR FINISH

WALL ASSEMBLY , RE: FLOOR PLAN

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH

APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT

MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

1'-2"

AD

A C

OU

NT

ER

S

2'-6

"

1 1

/2"

2 1

/2"

26

" C

RIT

ICA

L

2'-2

"

2"

OPENING AS SCHEDULED

WALL & WALL FINISH AS SCHEDULED

FLUSH MOUNT MTL BRACKET. PROVIDE BLOCKING

PLASTIC LAMINATE ON1/2" PLYWOOD COUNTER

100242X34

100236X34

100236X34

100236X34

100236X34

100236X34

100236X34

100236X34

100242X34

2'-1" 28'-1" 2'-2"

09.1209.12

FILLER

CONFIGURATION

LAB

13127

A8.01

2'-1" 28'-2" 2'-1"

09.12 09.12

100242X34

100236X34

100236X34

100236X34

100236X34

100236X34

100236X34

100236X34

100242X34 FILLER

CONFIGURATION

LAB

131

COUNTER TOP AS SPEC'D

BASE AS SCHED.

PLAS. LAM. ON 3/4" PLYWOOD DRAWER/ DOOR FRONT w/ HANDLE AS SPEC'D w/ 1/4" GAP BETWEEN

DRAWER AND DOOR FRONTS, TYP.

ADJUSTABLE PLAS. LAM. SHELF

K&V #255 STANDARDS W/ #256 STEEL SUPPORTS

1/4" PLYWOOD BACK LET INTO TOP AND BOTTOM PANELS OF CABINET

PLAS. LAM ON 3/4" PLYWOOD

6"

1'-0

"

EQ

EQ

RE

F. E

LE

V.

RE

F. E

LE

V.

RE

F. E

LE

V.

SUSP CEILING AS SCHED. RE: RCP

PLAS. LAM ON 5/8" GYP BOARD

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD RE: ELEVATION FOR FINISH

TILE, RE: ELEVATION FOR FINISH

WALL ASSEMBLY , RE: FLOOR PLAN

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH

APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT

MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

1 x NAILER TYPICAL

PLASTIC LAMINATE ON 3/4" PLYWOOD SHELVES ON ADJUSTABLE SUPPORT BRACKETS (TYPICAL)

BACKSPLASH, RE: INTERIOR ELEVATION

SINK BEYOND

2'-6"

6" MTL STUD

UNDER CABINET LIGHT FIXTURE TYPE "J" TYPICAL FOR UPPER CABINETS. RE: ELEC

110236X34

133518X34

133518X34

2'-1

0"

09.15

09.12

11'-0"

FILE

STORAGE

132

133518X30

09.1209.15

6'-4 1/4"

FILE

STORAGE

132

PLASTIC LAM. TOP, SPLASH, AND RETURN ON 3/4" PLYWOOD

2' - 0" 3/4"

1 1

/2"

4 1

/2"

8" MIN.

8"

MIN

.

9"

1x2 WOOD FRAMING

REMOVEABLE PLAS. LAM. ON 3/4" PLYWOOD APRON. HANG WITH CONCEALED HARDWARE

SINK AS SPEC'D.REF: PLUMBING

BASE CABINET BEYOND

1/4" PLYWOOD BACK LET INTO TOP AND BOTTOM PANELS OF CABINET

K&V #255 STANDARDS W/ #256 STEEL SUPPORTS

PLAS. LAM ON 3/4"PLYWOOD ADJ. SHELVES

1 1

/2"

PLAS. LAM. ON 3/4" PLYWOOD DRAWER/ DOOR FRONT w/ SATIN NICKEL PLATED HANDLE (TYP. AT ALL DRAWERS/ DOORS) w/ 1/4" GAP BETWEEN DRAWER AND DOOR FRONTS, TYP.

LOCK

UPPER CABINET IF APPLICABLE

RE

F. E

LE

V.

RE

F. E

LE

V.

RE

F. E

LE

V.

UNDER CABINET LIGHT FIXTURE TYPE "J" TYPICAL FOR UPPER CABINETS. RE: ELEC

6"

1'-0

"

SUSP CEILING AS SCHED. RE: RCP

PLAS. LAM ON 5/8" GYP BOARD

CEILING HEIGHT

6"

CEILING HEIGHT

5/8" GYP BOARD RE: ELEVATION FOR FINISH

TILE, RE: ELEVATION FOR FINISH

3-5/8" MTL STUD AT 16" OC MAX TO STRUCT DECK ABOVE, ATTACH EACH STUD TO CONT 3-5/8" MTL RUNNER TOP TRACK WITH APPROPRIATELY SIZED FASTENERS EACH SIDE OF STUD, REFER TO TYP BULKHEAD STUD FRAMING TO DECK DETAIL

3-5/8" MTL STUD BRACE TO STRUCT ABOVE AT 48" OC MAX

MTL CLIP ANGLE AT EACH STUD

CONT COLD-ROLLED MTL CHANNEL BRIDGING AT 48" OC VERT MAX AND WITHIN 18" VERT MAX OF TOP OF STUD FRAMING AND WITHIN 18" VERT MAX OF BOTTOM OF STUD FRAMING, ATTACH TO EACH CLIP ANGLE

CONT 3-5/8" MTL RUNNER TRACK, ATTACH TO WALL FRAMING SUBSTRAIT

BACKSPLASH, RE: INTERIOR ELEVATION

1'-6" CLEAR

T166.2B

08.01 133518X34

133518X34

133518X34

10.10

110236X34

10.1010.10

133518X34

133518X34

10.1009.15

09.15

10.10 10.10

110236X34

133518X34

133518X34

10.1010.1009.15

133518X34

110236X34

133518X34

110236X34

133518X34

110236X34

10.1010.1010.1010.10 10.1010.1009.15

10.10

133518X34

09.15 10.10

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL AG&E

MEPT

PLAN NORTH

KEY PLAN TRUE NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

1200 SUMMIT AVE. SUITE 420FORT WORTH, TX 76102

817-529-7240 P

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

A

ARCHITECT in2arch.com

B

ARCHITECTURE

12222 Merit Drive, Suite 1140Dallas, Texas 75251

972-427-1222 P

4/8

/2019

9:0

7:1

3 P

M

C:\U

se

rs\e

dore

\Docum

ents

\18

204

BIS

D P

laza-T

echno

log

y B

ldg

_A

17_e

dore

.rvt

BIS

D P

LA

ZA

TE

CH

NO

LO

GY

SE

RV

ICE

S

ISS

UE

FO

R C

ON

ST

RU

CT

ION

A8.02

CASEWORK

ELEVATIONS &

DETAILS

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

Aut

hor

Che

cker

6321

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

3/4" = 1'-0"10 CABINET SECTION

1" = 1'-0"11 RECEPTION SECTION

1/4" = 1'-0"2 CONFIGURATION LAB RM 131 NORTH ISLAND

1/4" = 1'-0"4 CONFIGURATION LAB RM 131 SOUTH ISLAND

3/4" = 1'-0"8 CABINET SECTION

1/4" = 1'-0"6 FILE STORAGE RM 132 NORTH ELEVATION

1/4" = 1'-0"5 FILE STORAGE RM 132 WEST ELEVATION

1" = 1'-0"18 CABINET SECTION

1

1

1

1

1/4" = 1'-0"20 CONFIGURATION LAB RM 131 NORTH

1/4" = 1'-0"22 CONFIGURATION LAB RM 131 EAST

1/4" = 1'-0"26 CONFIGURATION LAB RM 131 SOUTH

1/4" = 1'-0"28 CONFIGURATION LAB RM 131 WEST

No. Description Date1 ADDENDUM #01 03/28/2019

3 ADDENDUM #03 04/09/2019

3

3

3

3

Addendum 03 - Page 32 of 33

Page 33: Birdville ISD Plaza Renovations...A. Deliver acoustical panels, suspension system components, and accessories to site in original, unopened packages and store in a fully enclosed,

DO2

DO6

DP1

DP2

GX1

NI1

OS3

OS5

OS6

PO2

PP2

PT1

S1

S10

S2

S8

SC2

SO5

SW1

SW2

NBRG 8 KITBridge, Kit

DO2NWSX PDT LV DX XXWallSwitch Sensor, Passive Dual Technology,Low Voltage, Occupancy controlleddimming without dimming output;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

DO6WSX PDT D SA XXWall SwitchSensor, Passive Dual Technology,Occupancy Controlled Dimming, Vacancy(default) or Auto-On; COLOR/FINISH TOBE SELECTED PRIOR TO ORDERING

DP1NPP16 D EFPPower/RelayPack, Occupancy Controlled Dimming,External Fault Protection

DP2NPP16 D EFP SAPower/RelayPack, Occupancy Controlled Dimming,External Fault Protection, Vacancy(default) or Auto-On

GX1NPOD GFX XXLow VoltageWallpod, Graphic Touchscreen;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

NI1NIO X KITnLight Device,External Touch Panel Interface, Kit

OS3NWV 16 KITLow VoltageCorner Mount Sensor, Kit

OS5NCM 10Low Voltage CeilingMount Sensor, Large Motion / ExtendedRange 360ᄚ Lens

OS6NCM PDT 10Low VoltageCeiling Mount Sensor, Passive DualTechnology, Large Motion / ExtendedRange 360ᄚ Lens

PO2NCM PDT 10 ADCXLowVoltage Ceiling Mount Sensor, PassiveDual Technology, Large Motion / ExtendedRange 360ᄚ Lens, Photocontrol w/ AutoDimming; No Wires

PP2NPP16 EFP SAPower/RelayPack, External Fault Protection, Vacancy(default) or Auto-On

PT1PTS 60 XXPreset Timer Switch,60 Minute Max; ; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

S1NPODM XXLow VoltagePush-Button Wallpod; COLOR/FINISH TOBE SELECTED PRIOR TO ORDERING

S10NPODM 4S DX XXLow VoltagePush-Button Wallpod, 4 scene control,Raise/Lower Dimming Without Wires;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

S2NPODM DX XXLow VoltagePush-Button Wallpod, Occupancycontrolled dimming without dimmingoutput; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

S8NPODM 2S DX XXLow VoltagePush-Button Wallpod, Occupancycontrolled dimming without dimmingoutput; COLOR/FINISH TO BESELECTED PRIOR TO ORDERING

SC2NECY MVOLT BAC ENCnLightEclypse, 120-277 VAC, BACnet, 14 1/4"Hx 14 1/4"W x 4"D metal enclosure forECLYPSE EnergySyte or nLight ECLYPSE.

SO5WSX SA XXWall SwitchSensor, Vacancy (default) or Auto-On;COLOR/FINISH TO BE SELECTEDPRIOR TO ORDERING

SW1NPODM 1SB XXLow VoltagePush-Button Wallpod

SW2NPOD KEY XXLow VoltageWallpod, Digital keyswitch

ACUITY BRANDS DEVICE LEGEND

BDG

N.T.S.

TYPICAL WIRING DIAGRAM: NPP16 EFP

WH

TnPP16 EFP

GRN

BLK

/OR

N

RJ45

RJ45

BLUE

HN

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

A

B

WIRE LEGEND

LINE VOLTAGE

CAT 5-E (CLASS 2)

B

B

B B

A

A

LUMINAIRE

BLK- 120V/ ORN- 277V

SWITCHING ONLY

(2)RJ45

PORTS:

+40mA

EACH TO ADDITIONAL

LUMINAIRES ON SAME

ZONE

RE

D

N.T.S.

TYPICAL WIRING DIAGRAM: NPP16 D EFP

BLUE

HN

WH

TnPP16 D EFP

VIOLETGRAY

GRN

BLK

/OR

N

RJ45

RJ45

LUMINAIRE

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

TO ADDITIONAL

NLIGHT DEVICES.

SEE LAYOUTS.

CC

B

B

B B

A

A

A

B

C

WIRE LEGEND

0-10 VDC

LINE VOLTAGE

CAT 5-E (CLASS 2)

BLK- 120V/ ORN- 277V

0-10V DIMMING

(2)RJ45

PORTS:

+40mA

EACH TO ADDITIONAL

LUMINAIRES ON SAME

ZONE

RE

D

NEUTRALLINE (120-277V~)

GROUND

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

BLK- 120V/

ORG 277V

WH

ITE

BLK

/OR

G

N H

PS 150

REDBLACK

NECY MVOLT BAC ENC

SC2

NBRG 8 KITSPARESPARESPARE

[MBRG]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-A]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-B]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5PORT 6SPARE

[BRG-C]

NBRG 8 KIT

PORT 1PORT 2PORT 3PORT 4

PORT 5SPARESPARE

[BRG-D]

1LIGHTING CONTROL DIAGRAMS (BASED ON ACUITY BRANDS)NOT TO SCALE

LIGHTING FIXTURE NOTES

KEY TO NOTE PREFIXES: "G" NOTES ARE "GENERAL" LIGHTING NOTES

THAT APPLY TO THE ENTIRE PROJECT. "S" NOTES ARE "SCHEDULE"

NOTES THAT APPLY TO SPECIFIC LUMINAIRES.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS, ELEVATIONS,

SECTIONS, AND DETAILS FOR THE EXACT LOCATION OF ALL

LUMINAIRES. ARCHITECTURAL PLANS SHALL GOVERN FOR LOCATION

AND LAYOUT. IF ARCHITECTURAL AND ELECTRICAL DRAWINGS

CONFLICT IN EXACT COUNT OR FIXTURE TYPE, PROVIDE THE

GREATER QUANTITY OR COST TYPE UNLESS OTHERWISE

INSTRUCTED.

REFER TO DIVISION 26 ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

LUMINAIRE AND ELECTRICAL REQUIREMENTS (LENS, AIR HANDLING

CHARACTERISTICS, T-BAR CLIPS, BALLAST, LAMPS, TIME FRAME FOR

SUBMITTAL OF SUBSTITUTE LIGHT FIXTURES FOR PRIOR APPROVAL,

ETC.).

FOR EACH SCHEDULED LUMINAIRE, PROVIDE ALL REQUIRED

APPURTENANCES FOR INSTALLATION IN APPLICABLE STRUCTURE OR

SPECIFIED ARCHITECTURAL CEILING. ALL LUMINAIRES SHALL HAVE

THE APPROPRIATE NEMA TYPE FRAME THAT IS COMPATIBLE WITH

THE CEILING SYSTEM SPECIFIED BY THE ARCHITECT. ELECTRICAL

DRAWINGS DO NOT INDICATE CEILING TYPES, CONTRACTOR SHALL

REFER TO ARCHITECTURAL PLANS TO DETERMINE CEILING TYPE

(GRID, FLANGE, SPLINE, SCREW SLOT, ETC.) AND PROVIDE

APPROPRIATE FRAME.

EXIT SIGNS AND OTHER LUMINAIRES SHALL NOT BE SUPPORTED BY

CEILING TILE. PROVIDE MOUNTING FRAME OR HANGERS TO

SECURELY FASTEN IN PLACE ALL LUMINAIRES MOUNTED IN CEILING

TILE. FRAMING MEMBERS OF A SUSPENDED CEILING SYSTEM MAY BE

USED WHERE DESIGNED FOR THE PURPOSE AND INSTALLED PER NEC

410-16(C).

WHERE A SURFACE-MOUNTED LUMINAIRE CONTAINING A BALLAST IS

TO BE INSTALLED ON COMBUSTIBLE LOW-DENSITY CELLULOSE

FIBERBOARD, IT SHALL BE LISTED FOR THIS CONDITION OR SHALL BE

SPACED NOT LESS THAN 1 1/2 INCHES FROM THE SURFACE OF THE

FIBERBOARD (NEC 410-76(B)).

REQUEST FOR SUBSTITUTION SHALL FOLLOW SPECIFIED

PROCEDURES AND SHALL INCLUDE A WORKING SAMPLE SUITABLE

FOR TABLE TOP EXAMINATION.

REPLACE EXISTING EXTERIOR WALLPACK LIGHTS WITH NEW LED

FIXTURE USING ONE-FOR-ONE REPLACEMENT, REFER TO

ARCHITECTURAL LIGHTING TYPE 'M'. REUSE EXISTING CIRCUITING

AND CONTROL AS APPLICABLE,

UNLESS OTHERWISE NOTED, MOUNT EXIT SIGN DIRECTLY ABOVE

EGRESS DOOR (MAXIMUM 24" ABOVE DOOR), PROVIDE WALL MOUNT

EXIT SIGNS IN HIGH CEILING AREAS, PROVIDE WINDOW MULLION

MOUNTING WITH CONCEALED WIRING WHERE REQUIRED.

COORDINATE EXACT ELEVATION WITH ARCHITECT PRIOR TO

ROUGH-IN.

G1.

G2.

G3.

G4.

G5.

G6.

G8.

G7.

S1.

LICENSED

PRO

FESSIONAL ENGIN

EER

STATE OF TEXAS

F-18672

LEAF ENGINEERS

DONALD C. RICHARDS

61525

Other

Architect

ARCHITECT PBK Architects, Inc.

STRUCTURAL NAME

MEPT

PLAN NORTHKEY PLAN TRUE

NORTH

DATE

PROJECT NUMBER

CLIENT

REVISIONS

FORT WORTH100 Throckmorton Street, Suite 1550

Fort Worth, TX 76102817-332-4333 P817-332-4339 FTX Firm: F-1608

PBK.com

DR

AW

N B

Y:

CH

EC

KE

D B

Y:

ADDRESSADDRESS

012-345-6789 P 012-345-6789 F

14001 Dallas Parkway, Suite 400Dallas, TX 75240

214-442-5808 P 972-233-1373 FTX Firm: F-18672

LEAFE N G I N E E R S

A COMPANYPBK

ARCHITECTURAL NAME

ARCHITECTURE

ADDRESSADDRESS

012-345-6789 P 012-345-6789 F

03/08/2019

A

B

4/9

/2019

10:4

4:2

9 A

M

C:\U

sers

\sw

ay\D

ocum

ents

\18204

BIS

D P

laza-T

ech B

ldg E

lec R

17_C

entr

al_

sw

ay.r

vt

BIS

D P

LA

ZA

TE

CH

NO

LO

GY

SE

RV

ICE

S

ISS

UE

FO

R C

ON

ST

RU

CT

ION

E0.02

LIGHTING FIXTURE

SCHEDULE

03/08/2019

18204

BIRDVILLE ISD

ISSUE FOR CONSTRUCTION

SW

MH

6321

BO

ULE

VA

RD

26 ,

NO

RT

H R

ICH

LAN

D H

ILLS

, TX

761

80

Sequence of OperationTypical Commercial Office

Private Office

ᄋ Lighting shall be controlled with [stand-alone] vacancy sensor with 0-10v dimming capability.

ᄋ Lighting shall be controlled with [stand-alone] vacancy sensor with On/Off operation only.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

Lobby

ᄋ Lighting shall be controlled with [stand-alone, networked] multi-zone preset dimming controls and time-clock functionality.

ᄋ Lighting shall be controlled with [stand-alone, networked] occupancy sensor with 0-10v dimming capability.

ᄋ Control stations shall be preset station for scene control, keypad or touch-screen.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

Corridors

ᄋ Lighting shall be controlled with [stand-alone, networked] dimming controls (for tuning) and time-clock functionality.

ᄋ Occupancy sensors to be used for after-hours control with controlled with time-clock.

ᄋ Lighting shall be controlled with [stand-alone, networked] occupancy sensor with 0-10v dimming capability.

ᄋ Override station shall be on/off override only.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

Open Office

ᄋ Lighting shall be controlled with [networked] dimming controls (for tuning) and time-clock functionality.

ᄋ Vacancy sensors to be used for after-hours control when controlled with time-clock.

ᄋ Lighting shall be controlled with [stand-alone, networked] vacancy sensor with 0-10v dimming capability.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

Conference Rooms

ᄋ Lighting shall be controlled with [stand-alone] vacancy sensors and multi-zone preset dimming controls.

ᄋ Control stations shall be preset station for scene control, keypad or touch-screen.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

ᄋ Shall allow for AV integration (via RS-232, ethernet)

Copy Room / Work Room

ᄋ Lighting shall be controlled with [stand-alone] vacancy sensor with 0-10v dimming capability.

ᄋ Lighting shall be controlled with [stand-alone, networked] vacancy sensor with On/Off operation only.

ᄋ Daylight sensors and dimming shall be used as required for spaces with more than 150w of lighting in daylight zones within space, per IECC 2015.

Storage Room

ᄋ Lighting shall be controlled with [stand-alone] vacancy sensor with On/Off operation only.

Restroom

ᄋ Lighting shall be controlled with [networked] occupancy sensor with On/Off operation only.

ᄋ Manual override shall use key switch

Time-clock Scheduling

ᄋ Shall include astronomical time-clock integral to processor.

ᄋ Schedules shall allow for:

o Weekday Openo Weekday Close o Weekend Open o Weekend Close

Occupancy / Vacancy Sensors

ᄋ Time-delays shall be set to factory default, no more than 30 minutes as required

No. Description Date3 ADDENDUM #03 04/09/2019

LIGHTING FIXTURE SCHEDULETYPE DESCRIPTION LAMP MANUFACTURER # MODELA 4" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPB 4" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPC 3" WIDE RECESSED LINEAR LED MARK ARCH LTG # SL2L-LOPD SUSPENDED LINEAR LED FLUXWERX # PF1E SUSPENDED PENDANT SQUARE LED PRUDENTIAL # BSQEM RECESSED RETRACTABLE LED CONCEALITE # 5000

EMERGENCY LIGHTEX EXTERIOR EGRESS LED LITHONIA # AFN-COLOR-EXT

EMEREGENCY LIGHTF RECESSED COVE LED ECOSENSE # SCDG RECESSED LINEAR LED MARK ARCH LTG # SL4L-LOPH RECESSED LINEAR SLOT LED FINELITE # HP-WSJ UNDER CABINET LIGHT LED FEELUX # TUN-35KK RECESSED DOWNLIGHT LED GOTHAM # EVO-SQL1 DECORATIVE PENDANT LED LOUIS-POULSON # PATERA-277V-LEDL2 DECORATIVE PENDANT LED OCL # ROYALE-LED1-30K-UNV-DM1W WAREHOUSE LIGHT, REFER TO ARCHITECTURAL LIGHTING TYPE 'L3'

3

3

Addendum 03 - Page 33 of 33