PRESENTATION ON SITE ANALYZER

TECH

VID

HYA

SITE

AN

ALYZ

ER

1

PRESENTED BY : NIRAJ KUMAR MAURYA

Page 2: best telecom training in delhi

TECH

VID

HYA

SITE

AN

ALYZ

ER

2

SITE ANALYZER is also known as ‘ SITE MASTER’SITE ANALYZER is same like VSWR meter , power meter etc. WHAT WE PERFORM BY USING SITE ANALYZER?1.VSWR MEASUREMENT2.RETURN LOSS MEASUREMENT3.CABLE LOSS MEASUREMENT4.INSERTION LOSS MEASUREMENT5.FORWARD POWER MEASUREMENT6.REFLECTED POWER MEASUREMENT

MANUFACTURERS:BIRD ELECTRONICS , USAANRITSU , JAPAN

AUTHORISED DISTRIBUTER IN INDIA ARE:1.AIMIL LTD. DELHI ( BIRD ELECTRONICS)2.MEERA AGENCY , DELHI ( ANRITSU)

Page 3: best telecom training in delhi

ADVANTAGES1) It can measure VSWR with respect to frequency.2) It can measure VSWR with respect to distance.3) It can give a graphical representation of the measurement.4) It can give multiple measurement at once.5) It can save measured traces( up to 500traces).6) We can export and import traces from site analyzer.7) It can measure the VSWR for a frequency range starting from 780-2500 Mhz. *It can be expanded up to 6000 MHz by upgrading the software.8) It can give a print out of the measured trace.9) We can recall the old trace and compare it with new trace.10) No requirement of BTS for measurement of :-a. VSWR .b. Return loss.c. Cable loss.d. Insertion loss.

TECH

VID

HYA

SITE

AN

ALYZ

ER

3

Page 4: best telecom training in delhi

REQUIREMENTS• For VSWR measurement, Return loss, cable loss & insertion loss:-a)Site analyzer.b)Calibration kit.c)Adapter (1/2”M – 7/8”F).d)Dummy load (50 ohm, 50W).e)Adapter (1/2”F – 7/8”F , 1/2”F – 7/8”M )f) Site analyzer software ( SA PC tool)g)Serial straight cable (DB-9)

TECH

VID

HYA

SITE

AN

ALYZ

ER

4

Page 5: best telecom training in delhi

DISPLAYBIIRD – 2500 Ex780 – 2500 MHz

On/0ffNight visionLED

Arrow button

Function button

Selection button

RS - 232 PRINTER RF antenna port 1/2”F

Charging

Fig.(a)Showing site analyzer

TECH

VID

HYA

SITE

AN

ALYZ

ER

5

Page 6: best telecom training in delhi

HOW TO HANDLE SITE ANALYZER?1) Put on the site analyzer by pressing on/off button and wait for few seconds.2) Site analyzer model no. ,serial no. ,and operating frequency range are appeared on display

as shown in fig (a).3) After that screen resumes to the mode in which the site analyzer was lastly switched off.

The 3 modes are :-a) Measure match mode:-It is used to measure VSWR, Return loss, cable loss & insertion loss.b) Fault location mode:-It is used to localize the fault only.c) Measure power mode:-It is used to measure the forward power and the reflected power.*Suppose site analyzer was switched off in fault location mode.4) Mode is fault location, so the screen changes to,

FAULT LOCATION

VSW

R

DISTANCE0 4501

1.5

TECH

VID

HYA

SITE

AN

ALYZ

ER

6

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

DISTANCE (m)0

35

1

1.5

M1

M1 1.25 32

HOLD

PRINT

Page 7: best telecom training in delhi

5) We want to check the VSWR, so for that we have to change the mode by pressing “MODE” function button. Now screen changes to, SELECT MODE

MEASURE MATCH

FAULT LOCATION

MEASURE POWER

UTILITY

6) Select the measure match by pressing selection button corresponding to the measure match option, now the screen changes to,

MEASURE MATCH

SAVE/RECALL

AUTO SCALE

VSW

R

FREQ. (MHz)780 2500

1

1.5

LIMIT TEST OFF

PRINT

RUN

TECH

VID

HYA

SITE

AN

ALYZ

ER

7

Page 8: best telecom training in delhi

7) Look at the screen carefully and try to figure out freq. scale, right now it is (780-2500)Mhz. But we are using GSM 900 band (890-960)Mhz. So we have to change the frequency range acc. to our requirement.

*Select the frequency range acc. to port of antenna. 8) To set the frequency press “CONFIGURATION” button, now the screen changes to,

FREQUENCY

SCALELINE LIMIT

CABLE LOSS

9) Select frequency.

START

STOP 2500

780 MHz

MHz

VSWRWe can change this VSWR into return loss here.

TECH

VID

HYA

SITE

AN

ALYZ

ER

8

Page 9: best telecom training in delhi

10 . Select start frequency by using left/right arrow button and enter the desired frequency i.e. ‘890’ here by using either numeric key pad or top/bottom arrow button.

11. Press enter.12. . Select stop frequency by using left/right arrow button and enter the desired frequency i.e. ‘960’ here by

using either numeric key pad or top/bottom arrow button.13. Press enter.14. Press ESCAPE , now screen changes to, MEASURE MATCH

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

FREQ. (MHz)890 960

1

1.5

CALIBRATION OFF

HOLD

PRINT

NOTE:- (a) By using the calibration process, we set the internal loss of site master to zero, it means VSWR of site master goes ‘1’ at zero meter distance.

(b) It is better to calibrate the site analyzer at each and every site. (c) To calibrate the site analyzer we use a calibration kit. ** The calibration kit contain three connectors:- (a) open connector (b) short connector (c) load connector.

TECH

VID

HYA

SITE

AN

ALYZ

ER

9

Page 10: best telecom training in delhi

• The calibration kit is shown as below:-

1/2”M

OPEN LOAD

SHO

RT

1/2”M1/2”M

15 . As per the above said note, we have to calibrate the site analyzer, otherwise our measurement will not be genuine one.

16. To calibrate the site analyzer the , press ‘CALIBRATION’ button

OPEN

SHORT

LOAD

CALIBRATION

TECH

VID

HYA

SITE

AN

ALYZ

ER

10

Page 11: best telecom training in delhi

17. Connect the open connector of calibration kit with RF antenna port site analyzer.18. Press open selection button.19. A line appear on the screen and screen change to.

OPEN DONE

SHORT

LOAD

CALIBRATION

20. In the above screen instead of OPEN, “OPEN DONE” appears.21. Remove the open connector from site analyzer and connect short.22. Press short selection button.23. A line appear on the screen and screen change to.

OPEN DONE

SHORT DONE

LOAD

CALIBRATION

TECH

VID

HYA

SITE

AN

ALYZ

ER

11

Page 12: best telecom training in delhi

24. In the above screen instead of SHORT, “SHORT DONE” appears.25. Remove the short connector from site analyzer and connect load there.26. Press load selection button.27. A line appear on the screen (load done flash on the screen and screen change to.

28. Remove the load connector from the site analyzer and connect an adapter there (1/2”M – 7/8”F).29. Connect the JUMPER CABLE with adapter and press “AUTO SCALE” button , screen changes to,

MEASURE MATCH

SAVE/RECALL

AUTO SCALE

LIMIT TEST

VSW

R

FREQ. (MHz)890

1

1.5

CALIBRATION FULL

960

AUTO SCALE

HOLD

MEASURE MATCH

SAVE/RECALL

AUTO SCALE

LIMIT TEST

VSW

R

FREQ. (MHz)890

1

1.5

CALIBRATION FULL

960

AUTO SCALE

HOLD

TECH

VID

HYA

SITE

AN

ALYZ

ER

12

Page 13: best telecom training in delhi

• ** Definitely the VSWR at peaks is high i.e. greater than 1.30 but we want to know the value of VSWR as well as frequency on which VSWR is high, so for that we require a “MARKER” to read the value accurately.

• Note:- (a) In the above graph there are 2 or 3 high peaks which means VSWR is high there, but we are not able to give the perfect value of VSWR as well as frequency.

• (b) If we put a marker on the graph, our problem can be resolved.• (c) In the site analyzer we can use up to 6 markers simultaneously on the screen but any one of those marker will

be in ‘ACTIVE’ mode, rest are in background.• (d) By using these markers we can take six readings of VSWR simultaneously.30. Press ‘MARKER’ button, screen changes to ,

M1

OFF

SELECT MARKER

TRIANGULER

• Note:- (a) First selection button shows marker no, it can be from M1 – M6. We can select any one at a time, but we can activate all one by one.

• (b) Second selection button shows the next action against the selected marker.31. Activate the M1 and press ‘ESCAPE’.

TECH

VID

HYA

SITE

AN

ALYZ

ER

13

Page 14: best telecom training in delhi

• The screen changes to,MEASURE MATCH

CALIBRATION FULLM1 1.20 920

• Note:- We can move markers anywhere on the graph by using 4 arrows button.• When we use top arrow button marker goes to peak directly.• When we use bottom arrow button marker goes to crust .• When we use the left and right arrow button marker move on the screen along with the trace.32. Press the ‘TOP’ arrow button and marker goes to peak, screen changes to,

M1 1.39 930

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

FREQ. (MHz)890

1

1.5

M1

960

HOLD

PRINT

MEASURE MATCH

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

FREQ. (MHz)890

1

1.5

CALIBRATION FULL

M1

960

HOLD

PRINT

TECH

VID

HYA

SITE

AN

ALYZ

ER

14

Page 15: best telecom training in delhi

33. Now the VSWR of the transmission line is ‘1.39’ , which is beyond the acceptable limit i.e. ‘1.30’.34. It means there is a fault in the transmission line. To rectify the fault , first of all we have to localize the fault.35. To check where is the fault, we have to change the mode of site analyzer from measure match to fault location.36. Change the mode and press the ‘AUTO SCALE’. Now the screen changes to,

FAULT LOCATION

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

DISTANCE (m)0 450

1

1.5

CALIBRATION FULL

HOLD

PRINT

NOTE:- (a) Normally site analyzer supports up to 500 m distance, but the distance scale should be as per our requirement ( length of transmission line plus 5 – 10m extra.

(b) This 5 – 10 m extra is to check the antenna also.37. We have to set the distance scale, for that press ‘CONFIGURATION’ button.

TECH

VID

HYA

SITE

AN

ALYZ

ER

15

Page 16: best telecom training in delhi

Now the screen changes to,

DISTANCE

LIMIT LINE

SMOOTH

CABLE TYPE

SCALE

38. Select distance by pressing selection button, now the screen changes to,

START DISTANCE

450

0 m

m

M

STOP DISTANCE

MAX. DISTANCE 450 m

UNIT

NOTE :- (a) Do not change the max, distance value.

TECH

VID

HYA

SITE

AN

ALYZ

ER

16

Page 17: best telecom training in delhi

39. Select START distance and STOP distance by using left/right arrow button and enter the desired distance here.40. Press ENTER then ESCAPE.*Suppose we have set the distance up to 35m.

FAULT LOCATION

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

DISTANCE (m)0 35

1

1.5

CALIBRATION FULL

HOLD

PRINT

41. No marker on the screen so activate it.Note:- (a) we have to activate the marker separately in both the modes (Measure match as well as Fault location)38. Activate the marker.

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

DISTANCE (m)0 35

1

1.5

CALIBRATION FULL

M1

M1 1.03 16

HOLD

PRINT

TECH

VID

HYA

SITE

AN

ALYZ

ER

17

Page 18: best telecom training in delhi

42. Put the marker on the peak by using top arrow button.

SAVE/RECALL

AUTO SCALE

LIMIT TEST OFF

VSW

R

DISTANCE (m)0

35

1

1.5

M1

M1 1.25 32

HOLD

PRINT

Note :- (a)Acc. To this graph fault is near 32m which may be near antenna port or outdoor jumper. (b) Do not consider the value of VSWR here.( most of the cases VSWR has lesser value than in measure

match.43. Rectify the fault and measure the VSWR in measure match , if still VSWR value high again localize the fault and

rectify that.44. Repeat this action till the VSWR value goes below than 1.30 , it means 1.30 in measure match mode.

TECH

VID

HYA

SITE

AN

ALYZ

ER

18

CALIBRATION FULL

Page 19: best telecom training in delhi

HOW TO SAVE THE READING/TRACE?1. We can save the reading either in measure match mode or fault location mode, site master will save both the

readings at once.2. To save the reading, press ‘SAVE/RECALL’ selection button.

MEASURE MATCH

SAVE

RECALL

LABEL

DELETE

TV – 1M 21/03/13

SETUP

3. Save function is used to save current trace.4. (a)Recall function is used to recall any old trace and compare with the new one. (b) to recall the trace, select the particular trace by pressing top / bottom arrow button and press ENTER. Now

the old trace will appear in background and new in main.

TECH

VID

HYA

SITE

AN

ALYZ

ER

19

Page 20: best telecom training in delhi

5. Edit function button: (a) It is used to edit or replace the old saved trace with current trace.(b) To edit the old trace, select the particular trace by using top / bottom arrow button and press edit , then ENTER.6. DELETE FUNCTION BUTTON is used to delete any old saved trace. Select the particular old saved trace by

top/bottom arrow button. Press delete then ENTER.7. To save the reading press SAVE FUNCTION BUTTON.

P A F K U Z ; ….

Q B G L V [ , ….

R C H M W ] SPACE …

S D N S X = ! …

P

Q

R

S

8. Once we give the name, press ENTER , Screen changes to previous mode i.e. Whether in measure match or fault location mode.

TECH

VID

HYA

SITE

AN

ALYZ

ER

20

DELETE

Page 21: best telecom training in delhi

HOW TO MEASURE POWER BY SITE ANALYSER ?REQUIREMENTS:-1) Site analyzer2) Jumper adapter (1/2”M – 7/8”M)3) Adapter (1/2”M – 7/8”F)4) Sensor (5W & 50W Element)5) RS – 232 serial straight cable.

TECH

VID

HYA

SITE

AN

ALYZ

ER

21

Page 22: best telecom training in delhi

ANTENNA

D-9 RS-232 SERIAL STRAIGHT CABLE

ADAPTER

JUMPER ADAPTER

SENSOR

RS - 232PRINTER

How to connect site analyzer while measuring FWD. & REF. power.

TECH

VID

HYA

SITE

AN

ALYZ

ER

22

Page 23: best telecom training in delhi

1) Change the mode to measure power.**A warning appear on the screen and screen changes to,

TECH

VID

HYA

SITE

AN

ALYZ

ER

23

SEARCHING SENSOR

WARNING!Do not apply external power to RF antenna port of site analyzer.

Page 24: best telecom training in delhi

2) Once the searching is complete for the sensor screen changes to,

MEASURE POWER

Watt

FWD.REF.

dBmdBm

0

50

TECH

VID

HYA

SITE

AN

ALYZ

ER

24

Page 25: best telecom training in delhi

THANK YOU TECH