Description
The Type 1000 Transducer is an electro-pneu-matic device that reduces a supply pressure to aregulated output pressure directly proportionalto an electrical input signal. The Type 1000accepts a wide range o supply pressures,ranging rom a minimum o 3 psig (0.2 BAR)above the maximum output up to 100 PSIG (6.9BAR). An integral pneumatic volume boosteris included in the design to provide high owcapacity (up to 12 SCFM/339 SLPM). Modelselections include general purpose, NEMA 4XType, extended range, high relie , intrinsicallysa e, and explosion proo .
Applications
The Type 1000 Transducer converts an electri-
cal signal to a pneumatic output which can beused to operate the ollowing:
Valve actuators Damper and louver actuators Valve positioners Controllers Relays Air cylinders Clutches and brakesUsed in:
Liquid, gas and slurry processing instrumen-tation
HVAC systems Paper handling controls Textile processing systems Energy management systems Petrochemical processing systems
Standard Features
Low Cost Built-in Volume Booster Small Size Field Reversible
Low Air Consumption Mounts at Any Angle Convenient External Span & Zero Adjusts
(Except or Explosion Proo Models) Light Weight Wide Supply Pressure Range Low Supply Pressure Sensitivity
Type 1000I/P & E/P Transducers
Principle o Operation
The Type 1000 Transducer is a orce balancedevice in which a coil is suspended in thefeld o a magnet by a exure. Current owingthrough the coil generates axial movement othe coil and exure. The exure moves againstthe end o a nozzle, and creates a back pressurein the nozzle by restricting air ow through it .This back pressure acts as a pilot pressure toan integral booster relay. Consequently, as theinput signal increases (or decreases, or reverseacting), output pressure increases proportional-ly. Zero and span are calibrated by turning eas-ily accessible adjusting screws on the ront aceo the unit. The zero adjusting screw causes thenozzle to move relative to the exure. The spanadjusting screw is a potentiometer that limits
the current through the coil. A thermistor circuitin series with the coil provides temperaturecompensation.
Split Ranging
The 4-20 mA input, 3-15 PSIG output model canbe recalibrated to provide 3-9 PSIG or 9-15 PSIGoutput, or split ranging applications.
Mounting
The Type 1000 transducers can be pipe, panel,or bracket mounted in any position. Positionsother than vertical will require recalibrationo the zero adjustment. For maximum outputpressure stability, the Type 1000 should bemounted in a vibration- ree location or such thatvibration is isolated to the X and Z axis shownon the dimensional drawings.
Field Reversible
All Type 1000 transducers are calibrated at theactory or direct acting operation but may be
used in the reverse acting mode by reversingthe polarity o the signal leads and recalibrat-ing. When calibrated or reverse acting applica-tions, the Type 1000 transducers provide aminimum o their ull rated output pressure (i.e.,
15, 27, or 30 PSIG) upon input signal ailure.Type 1000 or Extended Range
Description
The Bello ram Extended Range I/P and E/PTransducers are based on Bello rams provenType 1000 transducer line - the best sellingtransducers in the business.
The large span adjustment range o this lineallows recalibration to ft applications withoutput ranges rom approximately 3-35 PSIG(0.2-2.4 BAR) to 3-145 PSIG (0.2-10 BAR).
Type 1000 Transducers
The units accept supply pressures up to 150PSIG (10.5 BAR) and provide ow capacity to24 SCFM (677 SLPM).
The Type 1000 I/P and E/P Transducers aremore cost e ective and more accurate thantypical high output systems using transducerscoupled to boosting or multiplying relays.
Type 1000 with High Relie
Description
Expanding upon the proven accuracy, reliabil-ity, and rugged construction o the Type 1000General Purpose, these transducers provideextra ast blowdown or a very rapid releaseo downstream pressure. The extra relie eatumakes these units suitable or cylinder returnstroke actuation, air hoists, and similar applica-tions requiring ast exhaust. These units acceptsupply pressures to 100 PSIG (6.9 BAR), withoutput ranges rom 1-17 PSIG (0.07-1.2 BAR) t6-30 PSIG (0.4-2.1 BAR), and provide exhaustcapacities o 7 SCFM (336 SLPM).
-
7/27/2019 Bellofram tranductores
3/22
www.marshbellofram.com 800.727.5646
Type 1000 TransducersType 1000
General PurposeType 1000High Relie
Type 1000Extended Range
Type 1000Explosion Proo
Supply Pressure Range3 PSIG (0.2 BAR) above max.output to 100 psig (7 BAR)
3 PSIG (0.2 BAR) above max.output to 100 PSIG (7 BAR)
5 PSIG (0.4 BAR) above max.output to 150 PSIG (10.4 BAR)
(100 PSIG / 7 BAR or 2-60 PSIG /0.1-4.1 BAR models)
3 PSIG (0.2 BAR) above maxoutput to 100 PSIG (7 BAR)
Supply Pressure Sensitivity0.15% o span per1.5 PSIG (0.1 BAR)
0.15% o span per1.5 PSIG (6.1 BAR)
0.004% o span per1.0 PSIG (0.07 BAR)
0.15% o span per1.5 PSIG (0.1 BAR)
Linearity(terminal based)
-
7/27/2019 Bellofram tranductores
4/22
800.727.5646 www.marshbellofram.com
Type 1000 General Purpose Ordering In ormation
InputOutput*
Part Number Impedance(Nominal)BAR PSIG
4-20mA
0.2-0.6 3-9 961-072-000 90
0.6-1.0 9-15 961-073-000 90
0.2-1.0 3-15 961-070-000 180
0.2-1.9 3-27 961-074-000 220
0.4-2.1 6-30 961-075-000 220
0.07-1.2 1-17 961-116-000 250
0.2-1.0 3-15 961-089-000 180
10-50mA0.2-1.0 3-15 961-076-000 70
0.2-1.9 3-27 961-077-000 85
0.4-2.1 6-30 961-078-000 85
0-5V0.2-1.0 3-15 961-079-000 615
0.2-1.9 3-27 961-080-000 530
0.4-2.1 6-30 961-081-000 530
1-9V0.2-1.0 3-15 961-085-000 985
0.2-1.9 3-27 961-086-000 840
0.4-2.1 6-30 961-087-000 840
NOTE: For NEMA4X, add 004 su fx.
Type 1000 Extended Range Ordering In ormation
InputOutput*
Part Number Impedance(Nominal)BAR PSIG0-60mA 0.1-8.3 2-120 961-107-000 220
4-20mA0.2-8.3 3-120 961-111-000 260
0.1-4.1 2-60 961-117-000 225
0-10V 0.2-8.3 3-120 961-112-000 805
0-5V 0.1-4.1 2-60 961-118-000 500
Type 1000 High Relie Ordering In ormation
InputOutput*
Part Number Impedance(Nominal)BAR PSIG
4-20mA
0.2-0.6 3-9 961-130-000 90
0.6-1.0 9-15 961-131-000 90
0.2-1.0 3-15 961-132-000 180
0.2-1.9 3-27 961-133-000 220
0.4-2.1 6-30 961-134-000 220
0.2-1.0 3-15 961-135-000 180
0.07-1.2 1-17 961-136-000 250
10-50mA0.2-1.0 3-15 961-137-000 70
0.2-1.9 3-27 961-138-000 85
0.4-2.1 6-30 961-139-000 85
Type 1000 Options and Accessories
Part NumberExplosion Proo Mounting Kit 971-079-000
Explosion Proo Panel Mounting Kit 971-078-000DIN Rail Kit 010-115-000
Hirschman Connector Kit (3-prong) 971-126-000Filter Kit, 60 micron 010-139-000
Output Gauges Option 8 ie: last 3 digits become - 008Dielectric Strength Testing Option 12 ie: last 3 digits become - 012
NEMA 4X Type Enclosure Option Option 4 ie: last 3 digits become - 004
* For output pressures less than 3 PSI (0.2 BAR) orgreater than 30 PSI (21 BAR), the Type 1000 transducercan be coupled to Bello ram Type 75 pneumatic relay.Consult Applications Engineers or urther in ormatio
** NEMA 4 type enclosure option available on all input/output ranges. This option is separate rom explosionproo , NEMA 4 units.
OutletPr essure
FlexureCircuitBoard
Coil
Magnet Assembly
Nozzle Atmospheric
Pressure
PilotPressure
Exhaus tValve
SupplyPressure
SupplyValve
Atmosphere SupplyPressureRegulatedPressure
Agency Approval Notes
Filter NoteBello ram specifes the use o instrument quality air(clean, dry, oil- ree) or all transducers. The use oflters in the supply air system is highly recommend-ed. Contact us or in ormation on our fltersand flter regulators.
Factory MutualT-1000 I/P TransducersIntrinsically Sa e: Class I, Division 1, Groups A, B, C, & D, T6Non-Incendive: Class I, Division 2 , Groups A, B, C, & D, T6.T-1000 I/P / E/P TransducerExplosion Proo : Class I, Division 1, Group D, T6Dust-Ignition Proo : Classes II & III, Division 1, Groups E, F, & G, T6Type 4NEMA 4
Canadian Standards AssociationT-1000 I/P Transducers
Hazardous Locations: Class I, Group D; Class II, Groups E, F, & G;Class III; CSA Enc. 4NEMA 4 :I/P transducer, supply pressure 100 psig max, input 4-20mA, output 3-15 psig.Intrinsically Sa e and Non-Incendive Systems - For HazardousLocations: Class I, Groups A, B, C, & D; Class II, Groups E, F, & G; Class III:I/P transducer rated input 4-20mA, intrinsically sa e when connected through CSA Certifdiode sa ety barriers in accordance with Bello ram Installation Instruction.
Explosion proo , intrinsically sa e, and non-incendive ratings are not a ected by recalibor split range or reverse acting applications.
The Bello ram T-1000 Transducers were tested and ound to comply with ElectromagnetiCompatibility Directive e ective January 1, 1996. The relevant EMC specifcations testedwere the ollowing: EN 50081-1 (1992) and EN 50082-1 (1992). A Technical ConstructionFile, Serial #107 was written and Certifcate o Con ormity issued by a Competent Body.
-
7/27/2019 Bellofram tranductores
5/22
www.marshbellofram.com 800.727.5646
Type 1000 Explosion Proo Dimensional Drawing;
Optional Mounting Bracket & Hardware
Order kit #201-971-079-000Optional Mounting Hardware
Order Kit #201-971-078-000
Drawings and dimensionsare or re erence only.
Type 1000 Hazardous Location Use Ordering In ormation
InputOutput*
Part Number Impedance(Nominal)Agency Approvals
(See notes)BAR PSIGType 1000 Explosion Proo
4-20mA0.2-1.0 3-15 961-098-000 180 Explosion-Proo , Factory Mutual1
0.2-1.0 3-15 961-098-100 180 CSA Explosion Proo1-9v 20-100 3-15 961-142-000 985 Explosion Proo Factory Mutual1
Type 1000 Intrinsically Sa e
4-20mA
0.2-1.0 3-15 961-099-000 180 Intrinsically Sa e, Factory Mutual3,4
0.2-1.9 3-27 961-100-000 220 Intrinsically Sa e, Factory Mutual3,4
0.2-1.0 3-15 961-105-000 180 Intrinsically Sa e, CSA5
0.2-1.9 3-27 961-106-000 220 Intrinsically Sa e, CSA5
0.4-2.1 6-30 961-101-000 220 Intrinsically Sa e, Factory Mutual3,4
1.0-0.2 15-3 961-175-000 180 Intrinsically Sa e, Factory Mutual3,4
1.9-0.2 27-3 961-176-000 220 Intrinsically Sa e, Factory Mutual3,4
2.1-0.4 30-6 961-177-000 220 Intrinsically Sa e, Factory Mutual3,4
*For output pressures less than 3 psi or greater than 30 psi the Type 1000 transducer can be coupled toBello ram Type 75 pneumatic relay. Consult application engineers or urther in ormation.
-
7/27/2019 Bellofram tranductores
6/22
800.727.5646 www.marshbellofram.com
Description
The Type 1001 is a patented amily o electro-pneumatic instruments that is used to reduce asupply pressure to a regulated output pressurewhich is directly proportional to a two-wirecurrent or three-wire voltage input. This designincorporates closed loop sensing o the outputpressure to achieve excellent accuracy and vibra-tion stability. It also eatures a unique dampingcircuit which can be adjusted to prevent over-shoot and actuator hunting. Model selectionincludes General Purpose (NEMA 1), Rainproo(NEMA 3R), and Watertight/Corrosion Resistant(NEMA 4X). NEMA 4X models are also explosion-proo , and all models are intrinsically sa e.
Features
0.1% accuracy typical Closed loop pressure eedback controlminimizes e ects o vibration, temperature,supply pressure and mounting angle
Built-in volume booster provides ows up to12 SCFM
Easy access zero and span adjustment Damping pot prevents over shoot and hunting Low air consumption Mounts at any angle (NEMA 3R limited) Compact and lightweight Virtually no sensitivity to supply pressure
changes Removable orifce (screw) or easy
maintenance
ApplicationsThe Type 1001s precisely regulated pneumaticoutput can be used to operate:
Valve actuators Louver and damper actuators Valve positioners Relays Clutches and brakes Controllers Air cylinders
Industry Applications Include:
Liquid and Gas Processing Pulp and Paper Petrochemical Processing HVAC Systems Textile Productions Energy Management Environmental Control Medical Equipment
Calibration AdjustmentsThe Type 1001 contains multi-turn Zero and Spanadjustment potentiometers which are accessibleon NEMA 1 models by sliding the cover window
Type 1001I/P & E/P Transducers
open to its frst detent position. Pots are clearlydistinguished by legend on the cover. On NEMA3R and 4X models, the cover should be removed toreach the pots (marked Z or zero and S or span).
Adjust the pots clockwise to increase Zero andSpan as required to optimize actory set outputwith appropriate input signal and supply pressureapplied.
Damping AdjustmentTo eliminate undesirable system oscillation, theType 1001 eatures a unique damping adjust-ment. The output response is optimized tovarying downstream volumes by adjusting the
eedback time constant o the coil drive amplifer.This is accomplished on NEMA 1 models by slid-ing the cover window open to its second detentposition to expose the single-turn Damping Poten-
tiometer (remove the cover on NEMA 3R and 4Xmodels). To optimize response, turn the pot ullycounterclockwise until system oscillation is justeliminated. System oscillation may be observedby monitoring output pressure or by observingthe behavior o directly actuated system compo-nents in response to a changing input.
MountingThe Type 1001 transducers are designed to beposition insensitive. They can be panel, valve, orpipe mounted at any angle (see NEMA 3R limita-tion) without a need or in place recalibration.Panel mounting can be either direct or with thebracket urnished with each unit. Mounting holesare located on the bottom and side to providemaximum mounting exibility. Users may orderthe optional DIN Rail Adapter or a bracket suit-able or either valve or 2" pipe mounting. Specialpipe clamps may be ordered as a separate kit.
Type 1001 Transducers
Factory MutualT-1001 I/P and E/P TransducersIntrinsically Sa e: Class I, Division 1, Groups A, B, C, & D, T6 Ta = 40C Non-Incendive: Class I, Division 2, Groups A, B, C, & D, T6Entity Parameters: VMax = 28 V, IMax = 150 mA, Ci = 0.22 F, Li = 0.T-1001 I/P and E/P Transducers Explosion Proo : Class I,Division 1, Groups B, C, & D, T6Dust-Ignition Proo : Classes II & III, Division 1, GroupsE, F, & G, T6 Type 4XNEMA 4X
Canadian Standards AssociationT-1001 and T-1001XP I/P and E/P TransducersHazardous Locations: Class I, Groups B, C, & D; ClassII, Group E, F, & G; Class III; Encl 4NEMA 4 :I/P or E/P transducer, input 4-20,10-50mA dc, 0-5, 1-5, 1-9 &1-10V dc; supply voltage 40V dc max; supply current 100mAmax; maximum ambient temp 70C.Output pressure ranges:
Standard: 3-9, 9-15, 3-15, 3-27, 6-30, 1-17 psig.Extended: 0-15, 0-120 psig.
T-1001 I/P and E/P TransducersHazardous Locations: Class I, Division 2, Groups A, B, C, & D:
Agency Approval Notes
I/P transducer, rated input 4-20mA or 10-50mA, 30V dc max.E/P transducer, rated supply 24V dc, 10mA, rated 0-5, 1-5,1-9& 1-10V dc. IN COMPLIANCE WITH STD C22.2 No 213.Intrinsically Sa e and Non-Incendive Sys-tems - Hazardous Locations: Class I, Groups A, B, C, & D:I/P transducer, rated input 4-20mA or 10-50mA, 30V dc max;intrinsically sa e when connected through CSA Certifed zenebarrier devices or converters as per Bello ram InstallationInstruction.E/P transducer, rated supply 24V dc, 10mA; rated input 0-5,1-5, 1-9 & 1-10V dc; intrinsically sa e when connected througCSA Certifed zener barrier devices as per Bello ram Installa-tion Instructions.
The Bello ram T-1001 Transducers were tested and ound tocomply with Electromagnetic Compatibility Directive e ectiJanuary 1, 1996. The relevant EMC specifcations tested werethe ollowing: EN 50081-1 (1992) and EN 50082-1 (1992).A Technical Construction File, Serial #107 was written andCertifcate o Con ormity issued by a Competent Body.
-
7/27/2019 Bellofram tranductores
7/22
www.marshbellofram.com 800.727.5646
Type 1001: Exhaust Capacity
10 0.699 0.628 0.557 0.486 0.415 0.35
4 0.283 0.212 0.141 0.070 0SCFM 0 1 2 3 4 5 6
LPM 0 28 57 85 113 142 170 ReveRse Flow
PSIG BAR
P R e s s u
R e a b o v e
s e t P o i n t
Type 1001: Output Pressure Droop
10 0.699 0.628 0.557 0.486 0.415 0.35
4 0.283 0.212 0.141 0.070 0
SCFM 0 12 4 6 8 10 12 14 1LPM 0 57 113 170 227 283 340 397 45
FoRwaRd Flow , sCFM
PSIG BAR
o u t P u t
P R e s s u R e
Type 1001 Speci cations
Accuracy (per ISA 51.1) 0.10% o output span, typical 0.25% o output span, maximum (Guaranteed)
Hysteresis 0.01% o output span, typical0.10% o output span, maximum
Dead Band No e ect
Repeatability 0.01% o output span, typical0.10% o output span, maximum
Ambient Temperature E ect 0.004% o nominal span per F, typical0.022% o nominal span per F, maximum
Span 0.013% o calibrated span per F, typical0.022% o calibrated span per F, maximum
Temperature E ect 0.02%/F, zero and span e ects combined
Operating Temperature RangeBuna-N elastomersViton elastomers
-20F to 160F (-29 to 71C)0F to 160F (-18 to 71C)
Storage Temperature RangeBuna-N elastomersViton elastomers
-40F to 200F (-40 to 93C)-15F to 200F (-26 to 93C)
Vibration E ect Less than 0.5% o span per 1G,5-2000 Hz, 3G maximum, 3 axes
Mounting Position E ect Not measurable
Loop Load, I/P Transducer Less than 10 VDC drop at 20 mALess than 12 VDC drop at 50 mASupply Voltage, E/P Transducer
Intrinsically Sa e/NonincendiveGeneral Purpose
9 VDC to 28 VDC, less than 20 mA9 VDC to 40 VDC, less than 20 mA
Supply Voltage E ect No e ectSignal Impedance, E/P Transducer 6000 Ohm minimum
RFI/EMI E ect (NEMA 4X)Less than 0.25% o span change in output10V/meter, 20-1000 MHz.(Re erence SAMA PML 33.1-1978, 2-abc)
Supply Pressure Sensitivity No e ectAir Consumption: 0.07 SCFM (2 LPM) maximumSupply Pressure 100 psig (6.9 BAR) maximum
Port Sizes Pneumatic: 1/4 NPTElectrical: 1/2 NPT* For models with zero output capability maximum supply pressure = 40PSI (2.8 BAR) above maximum output, except or0-100 PSI and 0-120 PSI models that have a maximum supply pressure o 130 PSI (9 BAR) & 140 psi (9.7 BAR) respectively.
Bello ram specifes the use o instrument quality air (clean, dry, oil ree) or all transducers.Transducers should be used within the ollowing conditions:Dew Point < 35F (2C) (indoor); Oil Content < 1PPM; Particles < 3m.The use o flters in the supply air system is highly recommended. Contact us or in ormation on our flters and flter regulators.
Type 1001 Accessories
Kits PartNumber
Panel Mounting Kit 010135-000
Valve Mounting Kit*** 010134-000
2" Pipe Mounting Kit(Valve Mounting Kit is required) 010143-000
DIN Rail Adapter 010115-000
Cover or Locking Device Kit( or NEMA 4X enclosure only) 010136-000
Type 1 Orifce with Buna-N O-rings* 010137-000
Type 1 Orifce with Viton O-rings* 010137-002
Type 2 Orifce with Buna-N O-rings** 010137-001
Type 2 Orifce with Viton O-rings** 010137-003
Filter Kit, 60 microns 010139-000
Hirschmann Connector Kit(Din 43 650-A)(3 prong plug, O-ring sealed)
010142-000
Pressure Gauge Kit, 15 PSI 010138-000
Pressure Gauge Kit, 30 PSI 010138-001
Pressure Gauge Kit, 60 PSI 010138-002
Pressure Gauge Kit, 160 PSI 010138-003
* Type 1 Kits to be used with based output units an1-17 PSIG unit.** Type 2 Kits to be used with all other units.*** Supplied standard with Nema 4X
Type 1001 Specials Table
Input Output Comments Part Numbe
4-20 mA 20-100 kPa NEMA 1 962-145-000
4-20 mA 20-100 kPa NEMA 3R962-146-000
4-20 mA 0-200 kPa NEMA 1 962-148-000
-
7/27/2019 Bellofram tranductores
8/22
800.727.5646 www.marshbellofram.com
Span Potentiometer
Zero Potentiometer
Damping Potentiometer
Terminal Block
Ground Screw
1/2 NPT Electrical Port
Coil
Coil Wire Connector Removable Orifce
1/8 NPT Gauge Port
1/4 NPT Supply Pressure Port
Type 1001 Ordering In ormation9 6 0
Enclosures6 NEMA 1, General Purpose2
7 NEMA 3R, Rainproo2
8 NEMA 4X, Water-tight, Dust-tight, Corrosion Resistant, and Explosion-Proo2
_ _ CalibrationSee Input / Output matrix below1
Agency Approvals0 None1 Factory Mutual and CSA Explosion Proo
Options00 None06 Fluorocarbon Elastomeric Diaphragm
Notes to Nomenclature:1. Transducer operating in the voltage mode (E/P), can be adjusted with the span potentiometer or any input between
0-10 VDC. The input range is limited to a minimum 4VDC di erence between 100% and 0% Input voltage.2. Standard NEMA 1 enclosure is conversion coated only. Standard NEMA 3R and NEMA 4X enclosures are epoxy painted.
Type 1001 Standard Input/Output Matrix
PSIG 0-5 0-15 0-30 0-60 0-100 1-17 3-15 3-27 6-30 3-9 9-15 0-2 0-120
4-20 mA 19 06 20 08 09 05 02 03 04 00 01 13 0710-50 mA 11 16 A5 98 89 15 12 87 14 10 90 B1 170-5 VDC 21 26 18 28 29 25 22 35 24 30 31 B2 271-5 VDC A1 36 A6 38 39 97 32 33 34 50 41 B3 371-9 VDC A2 46 40 48 49 45 42 43 44 60 51 B4 471-10 VDC A3 56 B6 58 59 55 52 53 54 88 61 B5 570-10 VDC A4 66 70 68 69 65 62 63 64 80 99 23 67
-
7/27/2019 Bellofram tranductores
9/22
www.marshbellofram.com 800.727.5646
Front View Side View
Side View (Vertical Mount Only) NEMA 3R
Bottom View
Top View Atmosphere
Pilot Pressure
Supply Pressure
Regulated Pressure
-
7/27/2019 Bellofram tranductores
10/22
800.727.5646 www.marshbellofram.com
Side Views
Bottom View
Type 1001 EX Wiring Termination
PWB Terminal Block I/P Transducer E/P Transducer
Position 3 Positive (+) Supply (+)Position 2 No Connection CommonPosition 1 Negative (-) Signal (+)
-
7/27/2019 Bellofram tranductores
11/22
www.marshbellofram.com 800.727.5646
Type 1500 Description
The T-1500 is a new series o electro-pneumatictransducers that convert an electrical signalto a proportional pressure output. It providesprecision electro-pneumatic control to actuators,valves, positioners, fnal control elements andis ideally used or high- ow control devices.The Type 1500's compact size and accessibilityto ports and adjustments allow the unit to beinstalled in space-constrained locations or in amani old or multi-device control.
DIN rail and mani old assemblies are availablein kits that provide three, fve or ten mountingpoints.
An integral pneumatic volume booster is in-cluded in the Type 1500 design to provide high
ow capacity. (See specifcations or ow data.)Standard Features
Small ootprint, compact size Mani old mounting confgurations Built-in volume booster Electrical Connections: Conduit 12 NPT or
BSPT, Terminal Block, Hirschmann Connectors (DIN 43 650-A)
Supply and output ports onront and back o unit
Low air consumption External zero and span adjustments Low cost Field accessible orifce Electrical conduit connection
meets CE requirements
Options Available
Intrinsically Sa e (FM, CSA, ATEX) NEMA 4X (FM, CSA) Excludes Terminal Block
Applications
The T-1500 transducer can be used as an
electro-pneumatic control device to operate: Valve actuators Valve positioners HVAC systems Material handling systems Paper handling controls Automation systems Liquid and gas processing systems
Type 1500I/P & E/P Transducers
Principle o Operation
(See Fig. 2 and 6) The T-1500 Transduceris a orce balance device in which a coil issuspended in the feld o a magnet by a exure.Current owing through the coil generates axialmovement o the coil and exure. The exuremoves against the end o a nozzle and createsa back pressure in the nozzle by restricting air
ow. This back pressure acts as a pilot pressureto an integral booster relay. Consequently, asthe input signal increases (or decreases orreverse acting), output pressure increasesproportionally.
In the zero based T-1500, the output o thetransducer section is routed to an integral nega-tive bias booster relay. The bias relay allows thecomplete unit to regulate output pressure downto 0 psig/BAR. The bias relay also amplifes theoutput o the transducer which allows the zerobased units to regulate higher output pressuresthan the standard T-1500.
Zero and Span are calibrated by turning easilyaccessible adjusting screws on the ront aceo the unit (see Figures 3, 4, 5, 7, 8 and 9).The zero adjustment causes the nozzle to moverelative to the exure. The span adjustment isa potentiometer that limits the ow o currentthrough the coil. A thermistor circuit in serieswith the coil provides temperature compensa-tion.
Mounting
The T-1500 can be mounted at any anglebut should be calibrated a ter mounting. Formaximum output pressure stability, the T-1500should be mounted vertically in a vibration reelocation or such that the vibration is isolatedto the X and Z axis. The T-1500 can be in-line,panel, pipe, DIN rail or mani old mounted.
Air Connections
1. Supply Air must be instrument quality airregulated between 5 PSI above maximumoutput pressure up to 120 PSIG / 8.3 BAR(See table: Supply Pressure Range).
2. Instrument-quality air consists o :a. A dew point less than 35Fb. No particles larger than three micronsc. Maximum oil content o 1 ppm
3. All unused ports must be plugged.
Type 1500 Transducers
Supply
Connect supply to either o two ports markedIN on the base o the transducer. Avoid getting pipe sealant inside the piping or transduc
Output
Connect output to either o two ports markedOUT on the base o the transducer. Thesecond OUT port may be used or a pressugauge.
-
7/27/2019 Bellofram tranductores
12/22
800.727.5646 www.marshbellofram.com
Type 1500 Transducers
Standard Range Zero BasedHysteresis
-
7/27/2019 Bellofram tranductores
13/22
www.marshbellofram.com 800.727.5646
T-1500 Mani old and Adapter Kit
Principle o Operation
The T-1500 mani old assembly allows multipleT-1500 Transducers to be mounted in parallel.This minimizes the number o individual supplyair lines required. Mani olds are available tohold three, fve, or ten units. Each mani oldcomes with check valves so that a unit can bepulled o o the mani old or service or replace-ment without a ecting the whole mani old.(See Figure 1.)
Mounting
The mani olds may be mounted ush with awall or cabinet or may be mounted away romthe wall. Both mounting options are included inthe basic mani old kit. In addition, all fttingsrequired to mount the ull number o units ineach mani old are included in the basic kit. Anadditional adapter kit may be purchased whichcontains all o the hardware required to mani-
old mount a single T-1500 Transducer shouldthe need arise.
Air Supply Attachment
The air supply can be attached to either sideo the mani old via a 3/4 NPT connection orto the back o the mani old via a 3/8 NPT con-nection. A ter an air supply port is selected, theopen ports should be plugged using the plugsprovided with the mani old kit and a pneumaticsealant.
Output Air Attachment
Connect the output ports rom each o the
T-1500 Transducers to the bottom or back othe mani old. A ter connecting the transducers,plug the other 1/8 NPT ports using the plugsprovided and a pneumatic sealant.
T-1500 Mani old Adapter Kit
The T-1500 mani old kit includes the adapterkits required or each transducer.
Electrical Connections
Two brackets supplied with the mani old kitallow an electrical conduit to be attached tothe mani old. Mounting screws and nuts areprovided, and the brackets have an 11/64"
diameter hole which will ft standard 8-36 UNFor 8-32 UNC screws (not supplied).
ADAPTER PLATECAPTIVE SCREW
T1500 TRANSDUCER
ZS
INOUT
CHECK VALVES B
A
2.50"
63.5mm
3.50"
88.9mm
Figure 1 - Mani old Front View
Type 1500 Dimensions
Number oTransducers Length A Length B
37.57"
192.3 mm6.83"
173.5 mm
510.75"
273.1 mm
10.01"
254.3 mm
1018.70"
475.0 mm17.96"
456.2 mm
Type 1500 Mani old Ordering In ormationKit Part NumberT-1500 Wall Mount Kit, 3 unit 010-606-000T-1500 Wall Mount Kit, 5 unit 010-606-001T-1500 Wall Mount Kit, 10 unit 010-606-002T-1500 Mani old Adapter Kit (Replacement) 010-602-000DIN Rail Mounting Kit 971-140-000Pneumatic Repair Kit(3-15, 3-27 PSIG / 0.2-1.0, 0.2-1.9 BAR) 971-141-000
Pneumatic Repair Kit(6-30 PSIG / 0.4-2.1 BAR) 971-141-002
Pneumatic Repair Kit, Fluorocarbon
(3-15, 3-27 PSIG / 0.2-1.0, 0.2-1.9 BAR)971-141-003
Pneumatic Repair Kit, Fluorocarbon(6-30 psig / 0.4-2.1 BAR) 971-141-004
Pneumatic Repair Kit(0-120 PSIG / 0-8.3 BAR) 971-145-000
Pneumatic Repair Kit Fluorocarbon,(0-120 psi / 0-8.3 BAR) 971-145-001
Electronic Repair Kit (4-20 mA) 971-142-000Electronic Repair Kit (0-5 VDC or 1-5 VDC) 971-142-001Electronic Repair Kit (1-9, 1-10 VDC, or 0-10 VDC) 971-142-0022" Pipe Mounting Kit 971-159-000Filter Kit, 60 Micron 010-139-000
-
7/27/2019 Bellofram tranductores
14/22
800.727.5646 www.marshbellofram.com
Type 1500 Extended Range Parts
Number Description1 Circuit Board2 Worm Gear3 Duckbill Valve (NEMA 4X Only)4 Magnet Assembly
5 Nozzle Assembly6 Bonnet Gasket (NEMA 4X Only)7 Servo Diaphragm (I/P Section)8 Control Diaphragm (I/P Section)9 Pintle10 Supply Seat11 Coil/Flexure Assembly12 Servo Diaphragm (Bias Relay)13 Control Diaphragm (Bias Relay)14 Orifce Screw15 Bias Spring
Figure 2: Type 1500 Extended Range Parts
Figure 3: Terminal Block
IN
IN
OUT
OUT
Z SPANADJUSTMENT
ORIFICESCREW
ZEROADJUSTMENT
S
2.87"62.9mm
5.27"133.9mm
2.25"57.2mm
Back Dimensions
IN
OUT IN
OUT
10-32 UNF-2BMOUNTING
HOLES
3.51"89.2mm
2.01"51.1mm
0.52"13.22mm
1.00"25.4mm
1.52"38.6mm
0.77"19.6mm
Figure 4 - Hirschmann (DIN 43 650-A)
IN
IN
OUT
OUT
TERMINAL "2" TERMINAL "1"
SAFETY GROUND
SPANADJUSTMEN T
SZ
ZEROADJUSTMENT
ORIFICESCREW
5.27"133.9mm
2.77"70.4mm
2.25"57.2mm
FIGURE 5: 1/2 NPT / BSPT
2.25"57.2mm
SPANADJUSTMENT
S
ZEROADJUSTMENT
ORIFICESCREW
Z
IN
IN
OUT
OUT
5.27"133.9mm
3.16"80.3mm
Drawings and dimensions are or re erence only.
Type 1500 Extended Range Dimensions
-
7/27/2019 Bellofram tranductores
15/22
www.marshbellofram.com 800.727.5646
Type 1500 Standard Range PartsNumber Description
1 Circuit Board2 Worm Gear3 Duckbill Valve (NEMA 4X Only)4 Magnet Assembly5 Nozzle Assembly6 Bonnet Gasket (NEMA 4X Only)7 Servo Diaphragm (I/P Section)8 Control Diaphragm (I/P Section)9 Pintle10 Supply Seat11 Coil/Flexure Assembly
Figure 6: Type 1500 Standard Range Parts
Figure 7: Terminal BlockBack Dimensions
Figure 9: Hirschmann (DIN 43 650-A)
Type 1500 Standard Range Dimensions
FIGURE 8: 1/2 NPT / BSPT
INOUT
1.52"38.6mm
1.00"25.4mm
10-32 UNF-2BMOUNTING HOLES
0.77"19.6mm
2.01"51.1mm
0.52"13.2mm
ZEROADJUSTMENT
ORIFICESCREW
2.25"57.2mm
SPANADJUSTMENT
SZ
INOUT
3.77"95.8mm
2.87"72.9mm
2.25"57.2mm
SPANADJUSTMENT 3.77"
95.8mm
3.16"80.3mm
ZEROADJUSTMENT
ORIFICESCREW
SZ
INOUT
ZEROADJUSTMENT
ORIFICESCREW
2.25"57.2mm
SPANADJUSTMENT
3.77"95.8mm
2.77"70.4mm
SZ
OUT IN
Agency Approvals - Applies only to units ordered with approvals
Vibration Axes
Y
X
Z
Drawings and dimensions are or re erence only.
Factory MutualT-1500 I/P and E/P TransducersIntrinsically Sa e: Class I, Division 1, Groups A, B, C, & D, T4 Ta = 70C; Entity;Non-Incendive: Class I, Division 2, Groups A, B, C, & D, T4 Ta = 70CDust-Ignition Proo : Classes II & III, Division 1, Groups E, F, & G, T4 Ta = 70CSuitable: Classes II & III, Division 2, Groups F & G, T4 Ta = 70C Type 4XNEMA 4XEntity Parameters: VMax = 30 V dc, IMax = 100 mA, Ci = 0 F, Li = 0 mH.
Canadian Standards AssociationT-1500 I/P Transducers Hazardous Locations: Class I, Division 2,Groups A, B, C, & D; Type 4XNEMA 4X :I/P transducer, rated VMax = 30V dc, IMax = 100mA. Temp Code T4. Max ambient 70C.IN COMPLIANCE WITH STD C22.2 No 213.Intrinsically Sa e, Entity - Hazardous Locations: Class I, Groups A, B, C, & D;Class II, Group E, F, & G; Class III; Type 4XNEMA 4X :I/P transducer. Entity Parameters: VMax = 30V dc, IMax = 100mA, Ci = 0, Li = 0. Intrinsically Safewhen connected per Installation Instruction 010632. Temp Code T4. Max ambient 70C.
ATEXIntrinsically sa e for II 1 G EEx ia IIB T4 Tamb = -20 to 65CInput Parameters: VMax = 30V, Pi = 1W, Ii = 100 mA, Req = 180 OHMS,Ci = 0, Li = 24mH
Models are CE marked or use in the European Union, and meet the EMCheavy machinery directives.
The Bello ram T-1500 Transducers were tested and ound to comply withElectromagnetic Compatibility Directive e ective January 1, 1996.The relevant EMC specifcations tested were the ollowing: EN 50081-1(1992) and EN 50082-1 (1992). A Technical Construction File, Serial #107was written and Certifcate o Con ormity issued by a Competent Body
-
7/27/2019 Bellofram tranductores
16/22
800.727.5646 www.marshbellofram.com
Description
The Marsh Bello ram Type 2000 is a robustelectronic instrument that regulates an incom-ing supply pressure down to a precise outputpressure which is directly proportional to anelectrical control signal. The secret to the Type2000s precise, reliable per ormance under avariety o demanding environmental conditionsis a patented piezo-ceramic actuator with manyindustry-wide frsts.
The Type 2000 has been designed to meet theelectro-pneumatic needs o the world:
Field-selectable inputs and direct/reverse/split ranging
Multiple input/output/mountingconfgurations
Precise, reliable per ormance under extremeconditions o temperature, vibration, orienta-tion, supply pressure changes, supply voltagechanges, RFI/EMI, humid / oil-laden media,and corrosive surroundings
Applications
The Type 2000s precisely regulated pneumaticoutput can be used to operate:
Valve Actuators Louver and Damper Actuators Valve Positioners Relays Clutches and Brakes Controllers Air Cylinders
Industry Applications Include
Chemical and Petrochemical Industries Petroleum Production Pipeline Transmission Electric Utilities Water and Wastewater Systems Pulp and Paper Textiles Semiconductor Industry Food and Beverage Environmental Control Systems Construction Equipment Agricultural Equipment Machine Tool Material Handling Automotive Testing and Assembly Medical Equipment
Type 2000I/P & E/P Transducers
Principle o Operation
The Type 2000 I/P and E/P transducers utilizeclosed-loop pressure eedback-control or preci-sion pressure output and minimized e ects otemperature, supply pressure changes, supplyvoltage changes, and mounting angle.
Supply pressure is reduced by the supplyvalve to provide an output pressure which isinternally routed to a precision temperaturecompensated piezo-resistive pressure sensor.Supply pressure is also routed to an externallyremovable orifce which provides a reducedpilot pressure to a chamber containing aservo diaphragm and nozzle. Pilot pressure iscontrolled by modulating the gap between the
ace o a nozzle and an adjacent piezo-ceramicactuator, which is part o a unique patentedmechanism.
The piezo-ceramic actuator serves as a controllink between electrical input and pressureoutput as ollows:
The input current (I/P) or voltage (E/P)signal is conditioned to provide a normalizedcontrol signal directly proportional to thedesired pressure output.
Simultaneously the output o the pressuresensor is amplifed and conditioned to pro-duce a eedback signal.
The sum o the control signal and the eed-
back signal produce a command signal whichis delivered as a DC voltage to the piezo-ceramic actuator.
As voltage increases, the orce applied by theactuator increases, so as to restrict nozzlebleed and thus increase pilot pressure.
Increased pilot pressure applied to the servodiaphragm directly causes opening o thesupply valve and an increase in the outputpressure until the output eedback signal andcontrol signal combine to produce the correctcommand signal.
Fine-Tuning Your Application
For optimal per ormance in your application, thecalibration o the Type 2000 can be fne-tunedin the feld. An easily-removable cover providesaccess to the isolated electronics. All potenti-ometers, connections, jumpers, and switchesare clearly marked on the circuit board or onthe handy chart located on the inside o thecover. The three elements o calibration (Gain,Zero, and Span) are described below. Consultthe Type 2000 Users Manual or detailedcalibration procedures, cautions, and instrumen-tation requirements.
Type 2000 Transducers
Gain (Damping) Adjustment
The output response o the Type 2000 can beoptimized or varying downstream volumes byadjusting the system gain o the control circuit.Adjust the Gain Pot counterclockwise or in-creased gain; clockwise or increased oscillatiodamping. For maximum allowable gain in yourapplication, the pot should be turned clockwiseuntil oscillation just disappears.
Zero and Span Adjustments
The Type 2000 contains multi-turn Coarse-ZeroFine-Zero, and Span adjustment potentiometers
which are clockwise positive. Adjustment oeither Zero Pot changes the units minimumoutput while the Span Pot changes the maxi-mum output. The adjustments are interactive,so it may take iterations to reach the desiredcalibration.
Wide Rangeability
The Type 2000 can be feld calibrated to pres-sure ranges other than the standard ones bycombinations o recalibration, pressure rangeswitching, and split high/low ranging. A unitshould not be switched to a range outside itspressure sensor amily (eg., a 0-15 PSIG can be
switched to a 3-15 PSIG, but not to 0-30 PSIG).(Caution: Do not exceed the range o the on-board pressure sensor.) For example, the easiestway to recalibrate a 0-30 PSIG unit to 3-15 psigwould be to change the switch setting to 3-27PSIG, then switch to split range low.
Field-Selectable Features
Onboard switches allow the user to easily recon-fgure the Type 2000 or any o several electricalinputs, direct/reverse acting, or output split-rang-ing high/low. Fine tuning o the units calibrationmay be necessary a ter a reconfguration.
-
7/27/2019 Bellofram tranductores
17/22
www.marshbellofram.com 800.727.5646
Easy Access Top Cover
1) Isolated electronics2) Calibration adjustments3) Confguration switches4) Switch in ormation on
inside o cover
Mounting Options1) In-Line2) Direct: Holes on le t
rear and bottom aces3) Bracket Mounting options:
Panel, Pipe, Valve, DIN-Rail
Integral BoosterFlows up to 21 sc m or quicksystem response
Gauge Port1/8 NPT on all models(Not shown; rear ace)
Mani old-Mounting OptionSupply and Output ports on thebottom ace rather than throughthe body
Electrical Port Options
1) 1/2 NPT Conduit2) 20mm Conduit3) Hirschmann (DIN 43 650-A)4) Terminal Block
Easy Access Orifce
Output PortSame as Input Port(Not shown; rear ace)
Input Port Options1) 1/4 NPT2) 1/4 BSPP3) 1/4 BSPT
Agency Approvals - Applies only to units ordered with approvals
Factory MutualT-2000 I/P & E/P Transducers Explosion Proo / Intrinsically Sa e ModelExplosion Proo : Class I, Division 1, Groups A, B, C, & D, T6 Ta = 60C
Dust-Ignition Proo : Classes II & III, Division 1, Groups E, F, & G , T6 Ta = 60C; Type 4XNEMA 4X , IP66Intrinsically Sa e: Classes I, II, & III, Division 1, Groups A, B, C, D, E, F, & G , T4 Ta =60C; Entity; Type 4XNEMA 4X , IP66Non-Incendive: Class I, Division 2, Groups A, B, C, & D, T4 Ta = 60CSuitable: Class II, Division 2, Groups F & G , T4 Ta = 60CSuitable: Class III, Division 2, T4 Ta = 60C, Type 4X, IP66Entity Parameters:Input Option b = 42: VMax = 30 V, IMax = 200 mA, PMax = 1 W, Ci = 0, Li = 0.Input Option b = 01, 05, 11, 15 or 19: VMax = 30 V, IMax = 100 mA, PMax = 0.75 W, Ci = 0, Li =0.Special Conditions o Use:The T-2000 Non-Incendive not or use with natural gas or other non-inert gases as a process medium.
T-2000 E/P or I/P Transducers Intrinsically Sa e ModelIntrinsically Sa e: Classes I, II, & III, Division 1, Groups A, B, C, D, E, F, & G, T4 Ta =60C; Entity;Non-Incendive: Class I, Division 2, Groups A, B, C, & D, T4 Ta = 60C
Suitable: Class II, Division 2, Groups F & G, T4 Ta = 60CSuitable: Class III, Division 2, T4 Ta = 60C Type 4XNEMA 4XEntity Parameters:When Electrical Input Optionc = 42: VMax = 30 V, IMax = 200 mA, PMax = 1 W, Ci = 0, Li = 0.When Electrical Input Optionc = 05, 15, 19, 11 or 01: VMax = 30 V, IMax = 100 mA, PMax = 0.75W, Ci = 0, Li = 0.
T-2000 E/P or I/P Transducers Intrinsically Sa e with Terminal Block ModelIntrinsically Sa e: Class I, Division 1, Groups A, B, C, & D, T4 Ta = 60C Entity;Non-Incendive: Class I, Division 2, Groups A, B, C, & D, T4 Ta = 60CEntity Parameters:When Electrical Input Option c = 42: VMax = 30 V, IMax = 200 mA, PMax = 1 W, Ci = 0, Li = 0.When Electrical Input Option c = 05, 15, 19, 11or 01: VMax = 30 V, IMax = 100 mA, PMax = 0.75W, Ci = 0, Li = 0.
Canadian Standards Association -T-2000 I/P & E/P TransducersHazardous Locations: Class I, Division 1, Groups A, B, C, & D; Class II, Groups E, F &G; Class III.
Explosion proo I/P & E/P Transducer , Rated: 28Vdc, 8mA;T-Code T6; Enclosure Type 4XNEMA 4X , IP66;Max Ambient Temperature: +60C. IN COMPLIANCE WITH STD C22.2 No 213.
T-2000 I/P & E/P TransducersIntrinsically Sa e, Entity - Hazardous Locations: Class I,Divisions 1 & 2, Groups A , B, C, & D; Class II, Division 1, Groups E, F, & G,Division 2, Groups F & G; Class III Hazardous LocationsElectro-Pneumatic I/P and E/P Transducers. Maximum Ambient Temperature:+60C. Enclosure Type 4XNEMA 4X , T4. Intrinsically Sa e when installed.Explosion proo : Class I, Division 1, Groups A, B, C & D; Class II, GroupsE, F, & G; Class III.NEMA 4XRated: 28Vdc, 8mA; T-Code T6; Enclosure Type 4X, IP66; Max AmbientTemperature: +60C. Intrinsically Sa e when installed. Two sets o EntityParameters may be used in the installation o this product.Entity ParametersI/P: VMax = 30V Imax = 200mA PMax = 1.0W Ci = 0mF Li = 0mHE/P: VMax = 30V IMax = 100mA PMax = 0.75W Ci = 0mF Li = 0mH
Direct/Reverse Acting
Direct Acting transducers regulate to their minimum output when suppliedwith minimum input; maximum out with maximum in. Reverse Actingtransducers regulate to their maximum output at minimum input.
Split Ranging (High or Low)
The Type 2000 can be confgured to regulate either hal (top or bot tomo its normal output range, when supplied with its normal ull-ranginelectrical input. For example, a 0-10V 0-30 PSI unit set to split range lwill regulate 0-15 PSI @ 0-10V. It will regulate 15-30 PSI @ 0-10V isplit range high.
ATEX (EUROPEAN MODEL)
T-2000 I/P & E/P TransducersINTRINSIC SAFETY: II 1 G EEx ia IIC T4 (-20
-
7/27/2019 Bellofram tranductores
18/22
800.727.5646 www.marshbellofram.com
Type 2000 Speci cations
Accuracy 0.1% o ull-scale output typical (0.25% guaranteed); includes e ects ohysteresis, dead band, and repeatabilityElectrical
Inputs Switch-Selectable4-20mA. 0-5, 1-5, 1-9, 1-10, or 0-10VDC
Connections1/2 NPT or 20mm ConduitDIN Hirschmann (S model only)
External Terminal Block (S model only)Power Supply 5-28VDC (with voltage inputs only)Direct/Reverse Acting Switch-Selectable
Pneumatic
Outputs0-5, 0-15, 3-15, 1-17, 0-30, 6-30, 3-27, 0-60, 0-100, or 120 PSIG0-0.1, 0-0.3, 0-1.0, 0.2-1.0, 0.07-1.2, 0-2.1, 0.4-2.1, 0.2-1.9,0-4.1, 0-6.9, 0-8.3 BAR
Ports (Input/Output) 1/4" (NPT, BSPT, or BSPP threads)Bottom-ported or Mani old MountingExhaust (Explosion proo only) 1/8 - 27 NPTPorts (Gauge) 1/8 NPT
Supply
For 05 PSIG (0.3 BAR) Through 060 PSIGFrom 5 PSIG (0.3 BAR) above maximum output to 100 PSIG maximumFor 0-100 PSIG and 0120 PSIG RangesFrom 5 PSIG (0.3 BAR) above maximum output to 140 PSIG maximum
Split-Ranging Switch-Selectable, Full-Range or Split-Range High or Split-Range LowConsumption 4 SCFH maximum (1.9 LPM)
Flow Capacity
Range Sensor FlowPSIG BAR PSIG BAR SCFM LPM0-5 0-0.3 5 0.3 11 3120-15 0-1.0 15 1.0 15 4233-15 0.2-1.0 15 1.0 15 4231-17 0.07-1.2 15 1.0 15 4230-30 0-2.1 30 2.1 15 4233-27 0.2-1.9 30 2.1 15 4236-30 0.4-2.1 30 2.1 15 4230-60 0-4.1 50 3.5 17 480
(Typical Flow @ 100 PSIG (6.9 BAR) in and maximum out)0-100 0-6.9 100 6.9 21 5950-120 0-8.3 100 6.9 21 595
(Typical Flow @ 140 PSIG (9.7 BAR) in and maximum out)Exhaust Capacity 3 SCFM (85 LPM) @ 5 PSIG (0.3 BAR) above setpoint(0-15 PSIG range unit set at mid range)Stability
Supply Voltage E ect NoneSupply Pressure E ect NoneVibration E ect
-
7/27/2019 Bellofram tranductores
19/22
www.marshbellofram.com 800.727.5646
Type 2000 Ordering In ormation2 K
EnclosureS Intrinsically Sa eE Explosion Proo
Electrical Port1N 1/2 NPT ConduitM 20mm Conduit S Unit OnlyH Hirschmann5T Terminal Block2 S Unit Only
Pneumatic PortsN NPTT BSPTP BSPPM Mani old Mount3
Agency Approval6F FM/CSAC ATEX S Unit OnlyG Certifed to CSA Standards4
Electrical Input42 4-20 mA05 0-5 V15 1-5 V
19 1-9 V11 1-10 V01 0-10 V
ModeD Direct ActingR Reverse Acting
ModeF Full RangeH Split Range HighL Split Range Low
Pneumatic Output005 0-5 PSIG 0-0.3 BAR
Maximum Supply orthese regulators is
100 PSIG
015 0-15 PSIG 0-1.0 BAR315 3-15 PSIG 0.2-1.0 BAR117 1-17 PSIG 0.07-1.2 BAR
030 0-30 PSIG 0-2.1 BAR630 6-30 PSIG 0.4-2.1 BAR327 3-27 PSIG 0.2-1.9 BAR060 0-60 PSIG 0-4.1 BAR
100 0-100 PSIG 0-6.9 BAR Maximum Supply orthese regulators is
140 PSIG120 0-120 PSIG 0-8.3 BARSpecial
00 None
Type 2000 Accessories
Part Number
Panel Mounting Kit 010-135-000
Valve Mounting Kit 010-134-0002" Pipe Mounting Kit(Valve Mounting Kit is required) 010-143-000
DIN Rail Adapter 010-115-000
Mani old Adapter Kit 971-158-000Filter Kit, 60 microns 010-139-000Pressure Gauge Kit15 PSIG (1 BAR) 010-138-000
Pressure Gauge Kit30 PSIG (2.1 BAR) 010-138-001
Pressure Gauge Kit60 PSIG (4.1 BAR) 010-138-002
Pressure Gauge Kit160 PSIG (11 BAR) 010-138-003
Type 2000 Notes
1 AvailabilityEnclosureS E
Electrical PortN Yes YesM Yes YesH Yes NoT Yes No
2 NEMA 4X / IP66 not available3 Bottom O-Ring Ports4 E Enclosure and
N Electrical port required5 Not Agency Approved6 Agency Approval F C G
FM/CSA ATEX Gas
EnclosureS IntrinsicSa ety Yes Yes No
E ExplosionProo Yes No Yes
Type 2000 Wiring Connections and Switch Positions
Switch # 1: PSIG BAR 2 3 4 5 6: psig BAR 7 8 9
ON
0-153-151-170-303-276-300-100
0-1.00.2-1.00.07-1.2
0-2.10.2-1.90.4-2.10-6.9
1-5 VDC0-5 VDC
Split LowVoltageInput(E/P)
Split LowFull
0-151-170-300-600-1000-120
0-1.00.07-1.2
0-2.10-4.10-6.90-8.3
ReverseActing
Full I/P
Switch # 1: PSIG BAR 2 3 4 5 6: psig BAR 7 8 9
OFF0-600-120
0-4.10-8.3
1-9 VDC0-10 VDC4-20 mA
FullSplit High
CurrentInput (I/P)
Split High3-153-276-30
0.2-1.00.2-1.90.4-2.1
DirectActing
Split LowSplit High
E/P
Terminal Block I/P Transducer E/P TransducS N/C + Signal
+ + Signal + Power Supply
- - Signal Common
-
7/27/2019 Bellofram tranductores
20/22
800.727.5646 www.marshbellofram.com
1.060
4.780
.570 TYP
2X 8-32 UNC-2B
X .375 DEEP
MOUNTING HOLES
OUT
2.225
2.939
2.307
M a r s
h
B e l l o f r a m
.360.716
1.893
.550
1.100
2X M3X0.5
X .250 DEEP
1/4-18 NPT TYP
3.883
1/2-14 NPT
IN
OUT
6.01
[152.6]
1.78
[45.2]
0.68[17.3]
0.57[14.5]
3.92
[99.5]
1.37
[34.7]
0.55[14.0]
1.10
[27.9]
2.06
[52.3]
2.12
[53.8]
Type 2000 Dimensions
Drawings and dimensions are or re erence only.
Type 2000 Explosion Proo Dimensions
-
7/27/2019 Bellofram tranductores
21/22
www.marshbellofram.com 800.727.5646
Description
The Type 5000 series is a compact , rugged andreliable amily o two-wire pressure transmit-ters designed or industrial feld service. Theseinstruments convert a signal pressure inputinto a precise 4-20 or 10-50mA output. Thelightweight transmitter housing includes a1/4 NPT pressure port and a 1/2 NPT conduitport or feld wiring. Connections are easilyaccessible simply by removing the top cover.Zero and span adjustments are available withinthe feld wiring compartment or fne, on-sitecalibration adjustment.
The Type 5000 uses a unique, temperaturecompensated piezo resistive sensor suitable orgauge pressure measurement o non-corrosiveliquids and gases. The sensor has excellentdynamic response and is vir tually insensitiveto mounting orientation and ordinary industrialvibration. Mounting holes on the transmitterhousing are arranged to permit direct pipe (2")mounting or minimum installed cost.
Type 5000P/I Transducers
Type 5000 P/I Transducers
Features
0.1% accuracy typical Piezo resistive pressure sensor resists vibration
Mounts at any angle Easily accessible zero and span adjustments NEMA 4X housing approved or explosion
proo service
Type 5000 Functional Diagram
TYPE 5000: Max Load Resistance VS. Supply Voltage
420 mA Output: RI = 50 ohms / volt 1050 mA Output: RI = 20 ohms / volt
l o a d
R e s i s t a n C e
( R i ) o h M s
s uPPly voltage (vs ) volts
Factory MutualT-5000 P/I Transducers NEMA 4XExplosion Proo : Class I, Division 1, Groups B, C, & D, T6Dust-Ignition Proo : Classes II & III, Division 1, Groups E, F, & G, T6,Type 4XNEMA 4X
Canadian Standards AssociationT-5000 P/I TransducersHazardous Locations :Class I, Groups B, C & D; Class II, Group E, F & G; Class III; Encl4 NEMA 4:P/I transmitter, rated output 4-20mA dc or 10-50mA dc, power supply 30Vdc max.
The Bello ram T-5000 Transducers were tested and ound to comply withElectromagnetic Compatibility Directive e ective January 1, 1996. The rel-evant EMC specifcations tested were the ollowing: EN 50081-1 (1992) andEN 50082-1 (1992). A Technical Construction File, Serial #107 was writtenand Certifcate o Con ormity issued by a Competent Body
Agency Approval Notes
-
7/27/2019 Bellofram tranductores
22/22
Type 1500 Speci cations
Input signal
015 PSIG 01.0 BAR315 PSIG 0.21.0 BAR327 PSIG 0.21.9 BAR630 PSIG 0.42.1 BAR
0.21.0 BAR 315 PSIG0100 PSIG 06.9 BAR
Output Signal420 mA DC, 2 wire1050 mA DC, 2 wire
Output Protections Reverse polarity protectedAccuracyincludes nonlinearity, hysteresisand non-repeatability
0.1% span typical; 0.25% span max.
Overpressure 45 PSIG (3.1 BAR) without calibration shi t60 PSIG (4.1 BAR) without ailureAllowable Loads See Graph
Response Time Less than 10 msec or step change to 99% R
Temperature Range-Operating -40F to +180F (-40C to +82C)
Temperature E ect Zero - Less than 0.01% R/FSpan - Less than 0.01% R/F
RFI E ect Less than 1% R at 10V/meter perSAMA PMC 33.1, 2-abcPower Supply 1230 VDC
Power Supply E ectLess than 0.005% per volt change at theinput terminals within specifed powersupply limits
Calibration AdjustmentsMulti-turn Zero and Span potentiometerswith 25% min. adjustment
In-Process Output MonitoringVia test jacks within enclosure withoutdisturbing feld wiring
Connections1/4 18 NPT emale pressure input,1/2 14 NPT emale electrical output
MountingSuitable bracket or optional 1/420 U-boltpipe mounting kit (P/N 971-109-000)
Finish Epoxy coated aluminum body and cover
Weight 1.7 lbs. (0.8 kg)
Type 5000 Dimensions
Type 5000 Ordering In ormation9 6 4 1
Input0 015 PSIG (01.0 BAR)1 315 PSIG (0.2 1.0 BAR)2 327 PSIG (0.21.9 BAR)3 630 PSIG (0.42.1 BAR)4 0.21.0 BAR (315 PSIG)5 0100 PSIG (06.9 BAR)
Output0 420 mA1 1050 mA
Agency approval1 X /P FM/CSA
Options000 None001 Pipe Clamp Mounting Kit