bearing frosting and the unique occurrence on a geared

22
ED CZECHOWSKI FS-ELLIOTT CHRIS NAPOLEON NAPOLEON ENGINEERING MIKE TURSKY FS-ELLIOTT CASE STUDY: BEARING FROSTING AND THE UNIQUE OCCURRENCE ON A GEARED CENTRIFUGAL COMPRESSOR

Upload: others

Post on 13-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Bearing Frosting and the Unique Occurrence on a Geared

ED CZECHOWSKI FS-ELLIOTT

CHRIS NAPOLEON NAPOLEON ENGINEERING

MIKE TURSKY FS-ELLIOTT

CASE STUDY: BEARING FROSTING AND THE UNIQUE OCCURRENCE

ON A GEARED CENTRIFUGAL COMPRESSOR

Page 2: Bearing Frosting and the Unique Occurrence on a Geared

Author Biographies

Ed Czechowski – Fellow Engineer at FS-Elliott since 2011.

Retired manager of New Product Development at Cameron

Compression systems. MSIT and BMET from Buffalo State

College. Advisory board member at both Buffalo State and the

University of Buffalo.

Chris Napoleon – Chris Napoleon is the President and Chief

Engineer for Napoleon Engineering Services. He received a B.S.

in mechanical engineering from the University of Pittsburgh and a

M.S. in manufacturing management from Kettering University. 23

Years experience in bearing testing and development.

Mike Tursky - Manager, Sustaining Engineering at FS-Elliott

Company since 2003. Former Product Design Engineer at Elliott

Turbomachinery Company. B.S. Aerospace Engineering from

Penn State University.

Page 3: Bearing Frosting and the Unique Occurrence on a Geared

Background

By definition, “Bearing Frosting” is term used to describe a

physical defect to a bearing surface caused stray

electrical currents.

It is similar in nature to “EDM” (Electrical Discharge

Machining) whereby bearing surfaces vaporize or soften

as electrical current passes through them.

It affects both conventional Babbitt style bearings as well

as anti-friction bearings.

Common to all types of drive/driven systems especially

steam turbines and VFD (variable frequency drive) driven

equipment.

Results in either slow or rapid increases in pinion vibration

and has a direct impact on machine reliability.

Page 4: Bearing Frosting and the Unique Occurrence on a Geared

Common Sources of Stray current

Induction Motor Stray

Currents – caused by time

varying flux encircling the

motor shaft from uneven

symmetry in motor windings

or from shipping damage. VFD harmonics – VFD’s

operate by rectifying AC

voltage to DC voltage and

subsequently inverting the

voltage back to AC via

high speed switching. This

HS switching creates a

current imbalance

between the three phases

and is often referred to as

“common-mode voltage”.

Page 5: Bearing Frosting and the Unique Occurrence on a Geared

Common Sources of Stray current

Static electricity on steam

exit side bearings

• Manufacturing processes –

part holders, lathes

• Magnetic base inspection

indicators

• Gear box Machining

processes

• Magnetic Particle inspection

• Space heater failure

• Welding on frame

• Motor feed and drains

• Group III oils

Page 6: Bearing Frosting and the Unique Occurrence on a Geared

How to Check for Stray Voltage

Carbon fiber shaft probe and

portable oscilloscope Electro-static charge detector

with a charge plate adapter

for use with a pipe probe

Page 7: Bearing Frosting and the Unique Occurrence on a Geared

Unique factors affecting a group of Geared Centrifugals: Case study focus

General location of frosted

bearing compressors

(highest annual humidity

readings in the country)

Type of location:

Virtually all the major

bearing failures have

occurred in

Petrochemical plants

that produce ethylene

based products

Page 8: Bearing Frosting and the Unique Occurrence on a Geared

High Humidity / Plastics Plant = Static Charge Influence

High Humidity

air is mixed with

charged

particles

100% saturated high

velocity air into the next

stage of compression

Charges can develop due to

base material location on the

Triboelectric series – metal is

neutral, polystyrene has strong

negative charge.

Note: Human hands have the

highest positive charge

Pinions can become

charged and the

combined effect of

the tribo-

electrification of oil

and charge potential

allow EDM to take

place.

Page 9: Bearing Frosting and the Unique Occurrence on a Geared

Case Study Example – two compressors one with a bull gear shaft grounding ring and one without.

Page 10: Bearing Frosting and the Unique Occurrence on a Geared

Initial Data from one of the Failed Units

The compressors in this case study all experienced alarm

and trip levels of vibration before being shut down for

bearing replacement. One unit exhibited a sudden shift in

vibration just hours after start up…an oversize pinion bore

caused by bearing frosting ended up being the problem.

0.0

5.0

10.0

15.0

20.0

25.0

30.0

14

:54

:40

14

:30

:54

14

:06

:54

13

:43

:53

13

:19

:53

12

:55

:53

12

:31

:53

12

:07

:53

11

:43

:53

11

:19

:53

10

:55

:53

10

:31

:53

10

:07

:53

9:4

3:5

3

9:1

9:5

38

:55

:53

8:3

1:5

38

:07

:53

7:4

3:5

37

:19

:53

6:5

5:5

3

6:3

1:5

36

:07

:53

5:4

3:5

35

:19

:53

4:5

5:5

34

:31

:53

4:0

7:5

3

3:4

3:5

33

:19

:53

2:5

5:5

32

:31

:53

2:0

7:5

31

:43

:53

1:1

9:5

3

0:5

5:5

30

:31

:53

0:0

7:5

32

3:4

3:5

3

23

:19

:53

22

:55

:53

Vib

rati

on

- M

icro

n

Page 11: Bearing Frosting and the Unique Occurrence on a Geared

Data Collected from Repaired Units

Unit Shaft Voltage Shaft Current Static Charge Comments

W/ Ground ring 31 mV rms 26 mA rms 170 - 515 V Static decayed over time

W/O GR 1.029 V rms .93- 1.02 A rms 50 – 360 V Cycled every eight minutes

Grounding Ring unit had better results

Unit w/ground ring Unit w/o ground ring

Page 12: Bearing Frosting and the Unique Occurrence on a Geared

Typical Sleeve and Thrust Bearing Damage

Page 13: Bearing Frosting and the Unique Occurrence on a Geared

Micro-cratering – damage

surface appears dull,

characterized by molten pit

marks

Rolling Element Bearing Damage

Page 14: Bearing Frosting and the Unique Occurrence on a Geared

Rolling Element Bearing Damage

Localized heat from

current passage creates

re-hardened surface layer

Fluting – resonance

vibration pattern from

over-rolling smaller micro-

craters

Page 15: Bearing Frosting and the Unique Occurrence on a Geared

Common Solutions to prevent stray currents on turbo machinery - economics

Drive motor with insulated rear bearing - $$

Insulated drive coupling - $$

Insulated forced feed lube and drains - $

Grounding straps on drive motor - $

Bull gear shaft grounding brushes - $

No welding stickers - $

Degaussing processes added - $$$

Material changes to bearings i.e. ceramic or ceramic coatings - $$$

Oil additives could be used to make the oil more conductive $$

* Actual $ depends on size of compressor frame involved

Page 16: Bearing Frosting and the Unique Occurrence on a Geared

Common Solutions to prevent stray currents on turbo machinery

Grounding Strap on Motor.

Bull gear Shaft Grounding Brushes.

Page 17: Bearing Frosting and the Unique Occurrence on a Geared

Common Solutions to prevent stray currents on turbo machinery

Insulated Bearings for Drive Motors

Insulated Drive Couplings

Page 18: Bearing Frosting and the Unique Occurrence on a Geared

Common Solutions to prevent stray currents on turbo machinery

Place “No Welding” Stickers on Compressor Equipment.

Degaussing Equipment to remove Magnetism in Parts.

Page 19: Bearing Frosting and the Unique Occurrence on a Geared

Case Study Findings

In this case we found that bull gear shaft stray currents were

the major contributor to frosted bearings. However, static

charges found at plastics plants showed a slow build up in

charge potential followed by an immediate discharge leading

us to believe that high speed pinions become electrified and that these charges also contribute to bearing damage.

* - refer to Summary

According to (Paschen’s

Law) electrostatic

discharges can occur as

low as 380 V.

Page 20: Bearing Frosting and the Unique Occurrence on a Geared

Summary

There are multiple ways that stray electrical currents can

develop in any given compressor.

Trying to stop each path could be very expensive and

time consuming.

There are two possible paths leading to the pinion bearings

Motor to bullgear

Static charged air to the impeller

OK Fix – make the oil more conductive

Good Fix - Although a bull gear shaft grounding system has

proven to effectively reduce bearing frosting, air side

charges must still cross the bull gear mesh in order to

ground out. This could damage the gear teeth over time.

Ultimate Solution – Direct grounding of both the bull gear

shaft and HS pinions on a geared centrifugal.

Page 21: Bearing Frosting and the Unique Occurrence on a Geared

Direct Pinion Grounding Recommendation

Location #1 Bullgear Shaft

Location #3 High Speed Rotor

Location #2 Low Speed Rotor

Page 22: Bearing Frosting and the Unique Occurrence on a Geared

Future Topic – Static Charges in Hydraulic Systems?

Questions?