beard im
DESCRIPTION
Bmr Commercial in association with our clients is pleased to offer these high grade industrial units to the market. The opportunity to acquire your own warehouse or lease one of the quality units is limited to four units. Please call Bmr Commercial today on 0402 673 547 to secure your new spaceTRANSCRIPT
Individual warehouse units providing 148.86m2, 176.26m2 & 203.1m2 total area and priced from $337,000.00 excluding GST
Office & amenities included within each unit as well as the potential to add mezzanine space if desired
High clearance space suitable for a wide range of business operations, all within these new, high grade industrial facilities
Integrated fit-out can be provided for those looking for walk in opportunities
On-site allocated and visitor parking complete the picture
4 UNIT DEVELOPMENT BLOCK 2 SECTION 5 BEARD ACT
* subject to unit entitlement
PHONE DAVID TONER 0402 673 547
HIGH GRADE WAREHOUSE SPACE OFFERED FOR SALE * OR LEASE
5
8
3
SCALE : 1 /
1200
SITE PLAN
PROJECT NAME
PROJECT No.
APPROVED
DESIGN
DRAWN
DATE
SCALE
CLIENT
NOTES
6
7
DRAWING NAME
ISSUES & REVISIONS
1
NO. DATE
2
3
4
5
DRAWING No.
COMPANY
8
6 Coal Court, Beard
A.C.T. 2620
T: 02 6284 3113
F: 02 6284 3110
1/200(A3)
SITE PLAN
RaE
design & build
RaE
design & build
4964
Drawing for Contract
A1.01
SECTION 5
BLOCK 2
BEARD
D.A.O. PTY LTD
AREA ANALYSIS
SITE AREA
GROSS FLOOR AREA
UNIT 1
WAREHOUSE FLOOR AREA
OFFICE FLOOR AREA
SUB TOTAL UNIT 1 FLOOR AREA
UNIT 2
WAREHOUSE FLOOR AREA
OFFICE FLOOR AREA
SUB TOTAL UNIT2 FLOOR AREA
UNIT 3
WARE HOUSE FLOOR AREA
OFFICE FLOOR AREA
SUB TOTAL UNIT3 FLOOR AREA
UNIT 4
WARE HOUSE FLOOR AREA
OFFICE FLOOR AREA
SUB TOTAL UNIT4 FLOOR AREA
DISABLED COMPLIANCE STATEMENT
THIS BUILDING HAS BEEN DESIGNED TO COMPLY WITH THE REQUIREMENT OF DISABLED
ACCESS AND MOBILITY IN ACCORDANCE WITH THE BCA AND AS 1428. ACCESS TO ALL
AREAS OF THE GROUND FLOOR IS PROVIDED THROUGH THE PRIMARY UNISEX TOILET.
THE TOILET WILL BE CONSTRUCTED AND FITTED OUT TO COMPLY WITH AS 1428.
ONE DISABLED CAR PARK HAS BEEN PROVIDED CLOSE TO THE ENTRY OF THE BUILDING
TO THE DIMENSIONS OF THE ACT PARKING AND VEHICLE ACCESS GUIDELINES
SAFETY IN DESIGN STATEMENT
WE DO NOT BELIEVE THAT THERE ARE ANY DESIGN ELEMENTS ASSOCIATED WITH THIS
PROJECT THAT WOULD POSE ANY UNUSUAL RISK TO HEALTH AND SAFETY THAT WOULD
BE CONSIDERED OUTSIDE OF THOSE NORMALLY EXPECTED FOR THIS BUILDING TYPE.
IF ANY PERSONS CONNECTED WITH THIS PROJECT CAN IDENTIFY ANY UNUSUAL RISKS
THAT NEED TO BE ADDRESSED, PLEASE CONSULT THE DESIGNER.
NOTE
- WORKING AT HEIGHT DURING CONSTRUCTION OF THE ROOF IS REQUIRED, SUFFICIENT
SAFETY MEASURES WILL HAVE TO BE TAKEN.
- ROOF ACCESS THROUGH AN ACCESS HATCH IS REQUIRED, SUFFICIENT SAFETY
MEASURES WILL HAVE TO BE PROVIDED TO ALLOW FOR SAFE TRAVEL ON THE ROOF.
DUST MANAGEMENT
1. A WATER CART OR SUFFICIENT WATER SPRAY SHALL BE AVAILABLE IN DRY AND WINDY
CONDITIONS TO MAINTAIN DUST SUPRESSION.
2. WATER SHALL BE APPLIED TO SUPPRESS DUST FROM OPEN EARTHWORKS AS WELL AS
UNPROTECTED STOCKPILES.
3. AREAS OF COMPLETED EARTHWORK SHALL BE PROGRESSIVELY REHABILITATED WITH
DRY AND GRASS.
4. THE CONTRACTOR SHALL CONTACT ACTEWAGL TO OBTAIN AN EXEMPTION TO USE
WATER ON THE SITE.
NOISE
1. ENSURE ALL BUILDING WORK THAT GENERATES NOISE IS
CONDUCTED WITHIN THE TIME PERIODS DETAILED IN
SCHEDULE 2 OF THE ENVIRONMENT PROTECTION REGULATIONS 2005.
N
03/04/14
Design Approval
1233 m2
647.41m2
191.72 m2
21.76 m2
213.48 m2
154.50 m2
21.76 m2
176.26 m2
122.10 m2
21.76 m2
143.86 m2
92.05 m2
21.76 m2
113.81 m2
30/06/14
PROJECT NAME
PROJECT No.
APPROVED
DESIGN
DRAWN
DATE
SCALE
CLIENT
NOTES
6
7
DRAWING NAME
ISSUES & REVISIONS
1
NO. DATE
2
3
4
5
DRAWING No.
COMPANY
8
6 Coal Court, Beard
A.C.T. 2620
T: 02 6284 3113
F: 02 6284 3110
ELEVATION,
1/100(A3)
RaE
design & build
RaE
design & build
Drawing for Contract
A6.01
D.A.O. PTY LTD
4964
SECTION 5
BLOCK 2
BEARD
SCALE : 1 /
2100
ENLARGED SOUTH ELEVATION
SCALE : 1 /
1100
ENLARGED EAST ELEVATION
4
EXTERIOR COLOUR SELECTIONS
TILT-UP CONCRETE WALL PANELS
- RAW CONCRETE
CONCRETE WALL WITH PAINT
- 'DULUX' ORANGE P09H9
ALUMINIUM WINDOW FRAME
- 'COLORBOND' MONUMENT
ROOF , AWNING
- 'COLORBOND' SULF MIST
GUTTERS, DOWN PIPES AND
ALL RAINWATER GOODS
- 'COLORBOND' SULF MIST
ROLLER SHUTTER DOORS
- 'COLORBOND' SURF MIST
SIGN
& COLOUR
FFL+583.70(W4)
FFL+585.20
03/04/14
SCALE : 1 /
4100
SIGN
Design Approval
SCALE : 1 /
3100
SIGN
ABC
321
30/06/14
4
3
2
1
PROJECT NAME
PROJECT No.
APPROVED
DESIGN
DRAWN
DATE
SCALE
CLIENT
NOTES
6
7
DRAWING NAME
ISSUES & REVISIONS
1
NO. DATE
2
3
4
5
DRAWING No.
COMPANY
8
6 Coal Court, Beard
A.C.T. 2620
T: 02 6284 3113
F: 02 6284 3110
ELEVATION
1/200(A3)
RaE
design & build
RaE
design & build
Drawing for Contract
A4.01
4964
SECTION 5
BLOCK 2
BEARD
D.A.O. PTY LTD
NO EXISTING BUILDING
SCALE : 1 /
1200
EAST ELEVATION
SCALE : 1 /
2100
WEST ELEVATION
SIGN
MESH FENCE H=2400
SKYLIGHT PANEL
IN CENTRE EACH BAY
- FULL ROOF WIDTH
SIGN
ALL SIGNS INSTALLED TO BUILDING FRONT AND SIDE TO BE IN ACCORDANCE WITH
- ACT SIGNS GENERAL CODE
FFL+585.20(W1)
GL+583.40
2
NO EXISTING BUILDING
COMPOSITE
STREETSCAPE
03/04/14
FFL+583.50(W4)
3
Design Approval
RAW CONCRETE PANEL WALL
LIGHTING
EXTERNAL LIGHTING PROVIDED TO BUILDING FRONT AND REAR INCLUDING CAR PARKING
AREA TO BE IN ACCORDANCE WITH
- AUSTRALIAN STANDARD 1158.1.3 PEDESTRIAN LIGHTING
- AUSTRALIAN STANDARD 4282 CONTROL OF THE OBTRUSIVE EFFECTS
OF OUTDOOR LIGHTING
4
ABCDE
A B C D E
TO ALLOW VEHICLES CLEAR LINE OFF SITE
ENTERING/EXITING DRIVEWAY
NO PART OF STRUCTURE
SHALL ENCROACH BEYOND BOUNDARY
INCLUDING FASICA, GUTTER AND FOOTING
METAL ROOF
MESH FENCE H=2400
TO ALLOW VEHICLES CLEAR LINE OFF SITE
ENTERING/EXITING DRIVEWAY
STEEL SLIDING INDUSTRY GATE
STEEL SLIDING INDUSTRY GATE
RAW CONCRETE PANEL WALL
NATURAL GROUND LEVEL
METAL ROOF
FFL+585.20(W1)
PROPERTY BOUNDRYPROPERTY BOUNDRY
PROPERTY BOUNDRY
PROPERTY BOUNDRY
NATURAL GROUND LEVEL
30/06/14
SCALE : 1 /
2200
SOUTH ELEVATION
PROJECT NAME
PROJECT No.
APPROVED
DESIGN
DRAWN
DATE
SCALE
CLIENT
NOTES
6
7
DRAWING NAME
ISSUES & REVISIONS
1
NO. DATE
2
3
4
5
DRAWING No.
COMPANY
8
6 Coal Court, Beard
A.C.T. 2620
T: 02 6284 3113
F: 02 6284 3110
ELEVATION
1/200(A3)
RaE
design & build
RaE
design & build
Drawing for Contract
A4.02
4964
SECTION 5
BLOCK 2
BEARD
D.A.O. PTY LTD
FFL+585.20(W1)
GL+583.50
1
COMPOSITE
STREETSCAPE
03/04/14
Design Approval
1 2 3 4 5 6 7 8 9
SCALE : 1 /
1200
NORTH ELEVATION
FFL+585.20(W1)
GL+583.50
123456789
SIGN
ALL SIGNS INSTALLED TO BUILDING FRONT AND SIDE TO BE IN ACCORDANCE WITH
- ACT SIGNS GENERAL CODE
LIGHTING
EXTERNAL LIGHTING PROVIDED TO BUILDING FRONT AND REAR INCLUDING CAR PARKING
AREA TO BE IN ACCORDANCE WITH
- AUSTRALIAN STANDARD 1158.1.3 PEDESTRIAN LIGHTING
- AUSTRALIAN STANDARD 4282 CONTROL OF THE OBTRUSIVE EFFECTS
OF OUTDOOR LIGHTING
FFL+583.70(W4)
30/06/14