    CS300Apogee Silicon Pyranometer

    Te CS300 uses a silicon photovoltaic detector mount-ed in a cosine-corrected head to provide solar radia-tion measurements or solar, agricultural, meteorologi-cal, and hydrological applications. Calibrated againsta Kipp & Zonen CM21 thermopile pyranometer, theCS300 accurately measures sun plus sky radiation orthe spectral range o 300 to 1100 nm. Sensors cali-brated to this spectral range should not be used undervegetation or artifcial lights.

    Te standard output is 0.2 mV per W m-2, which pro-vides a signal o 200 mV in ull sunlight (1000 W m-2).All o our dataloggers, including the CR200-series, canmeasure this output.

    ConstructionTe dome-shaped head prevents water rom accu-mulating on the sensor head. o eliminate internalcondensation, the sensor head is potted solid and thecable is shielded with a rugged Santoprene casing.

    Sensor MountsAccurate measurements require the sensor to beleveled using a 18356 leveling fxture. Tis levelingfxture incorporates a bubble level and three adjustingscrews. Te 18356 mounts to a tripod or tower usingthe CM225 mounting stand. For most applications,Campbell Scientifc recommends attaching the CM225to a CM202, CM204, or CM206 crossarm. Te CM225can also be attached to a tripod or tower mast.

    Ordering Inormation

    Silicon Pyranometer

    CS300-L Silicon Pyranometer with user speciied cable length;enter the cable length ater the L. An 11-t length(CS300-L11) is recommended or a 3-m mounting height.Must choose a cable termination option (see below).

    Cable Termination Options (choose one)

    -PT Cable terminates in stripped and tinned leads or directconnection to a dataloggers terminals.

    -PW Cable terminates in connector or attachment to aprewired enclosure.

    Accessories

    18356 Base and leveling fxture required to level the sensor.

    CM225 Mount or attaching to the 18356 and sensor to a tripod,tower, or vertical pipe.

    The typical confguration or attaching the CS300 to a tripod ortower is shown above.

    CS30018356 Base andLeveling Fixture

    CM225 MountCrossarm attachesto tripod or tower

    The 18356 levels the sensor in the horizontal plane, helping toensure accurate solar radiation measurements.

    Bubble level

    Adjusting screw

    Adjusting screw Adjusting screw

  • 7/30/2019 b_cs300

    2/2

    815 W. 1800 N. | Logan, Utah | 84321-1784 | US A | (435) 753-2342 | www.campbellsci.com

    Australia | Brazil | Canada | England | France | Germany | South Arica | Spain | USA [headquarters]

    Power requirements: none, sel-powered

    Absolute accuracy: 5% or daily total radiation

    Cosine response: 4% at 75 zenith angle1% at 45 zenith angle

    Temperature response: