Communication capabilities via a Web browser further expand air conditioning control possibilities. Convenient controllers that offer more freedom to administrators. Connectable to up to 128 Indoor units The number of connectable indoor units can be doubled by adding an external adapter (Optional) Control the Air Conditioning System from Elsewhere Centralized monitoring control system based on a Web browser (Optional) Malfunction Reports to a Mobile Phone, Anywhere Malfunction reports delivered by e-mail (Optional) Compatible with the 24-Hour Air Conditioning Network Service System Built-in modem for connecting to the Air Conditioning Network Service System (Optional) Basic Configuration and engineering for each project is necessary. Hardware intelligent Touch Controller DSC601C51 64 Groups 10 For further details, please consult your nearest Daikin Distributor or dealer. Item Model No. Max. indoor units Max. outdoor units Product data and engineering Option P.P.D. DCS002C51 Additional configuration and engineering for each project is necessary. Hardware D -NET Plus Adaptor DCS601A52 +64 Groups +10 Software Web DCS004A51 Specification Name Power supply Installation method condition for use Operating condition Dimensions Overseas certification LCD Panel Communication functions Input terminals Surrounding temperature/humidity (W × H × D) Safety of Information Technology Equipment Interference (EMC) Size/no. of dots/no. of colors D -NET ×1 10BASE-T Digital input Di ×1 Pulse input Pi ×3 Externally supplied 100 V AC–240 V AC 50/60 Hz JIS4 switchbox embedded in indoor wall 0°C to 40°C/less than 85% RH (if no condensation) 230 × 147 × 107 (mm) IEC60730 (including IEC60335) EN55022 Class-A , EN55024 5.7 inches / QVGA 320 × 240 / 4096 colors A/C equipment communication line Web option Forced Shutdown Power measuring pulse Externally supplied 100 V AC–240 V AC 50/60 Hz -10°C to +40°C/less than 90% RH 157 × 190 × 42 (mm) IEC60730 (including IEC60335) EN55022 Class-A , EN55024 A/C equipment communication line Power measuring pulse kWh meter item kWh meter Pulse transmitter Requirement Specification 1 Pulse to 1 kW or 10 kW pulse width must be within 40–400 m/sec. Output relay must be electronic type only. 1 Pulse to 1 kW or 10 kW pulse width must be within 40–400 m/sec. No voltage output intelligent Touch Controller (DCS601C51) D -NET Plus Adaptor (DCS601A52) PCN0410C Optional adapters Item Input Output Installation method Operating Condition Power supply Rated power consumption Applied standard Mass(Weight) Dimension surrounding temperature humidity 8pairs based on a pair of On/Off input and abnormality input indoor unstallation -10 to +40 10 to 85% AC200V-240V,50/60Hz 15W Safety standard : IEC730,EMC standard : CISPR22-A(EMI),CISPR(EMS) 2.5kg 198(H) 335(W) 70(D)mm 4pairs based on a pair of On/Off input and abnormality input In case of normally output, 4 units are controllable. In case of instaneous output, 2 units are controllable. Di unit (DEC101A51) Dio unit (DEC102A51) All rights reserved Printed in Japan 11/06/003 AD . HP . SW c Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ Printed on 100% recycled paper with soy ink. Specifications, designs and other content appearing in this brochure are current as of November 2006 but subject to change without notice. ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the About ISO 14001 ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the “ design, development, manufacture, installation, and supplementary service” of products manufactured at About ISO9001 JMI-0107 JQA-1452 EC99J2044 JQA-E-90108 Trademark of American Soybeen Association Printed on 100% recycled paper Using lntelligent touch controller 1. Installation of intelligent touch controller must be performed by a Daikin-trained engineer. 2. Once a month, adjust the clock of the intelligent touch controller. 3. Daikin’ s unique P.P.D. system estimates the power consumption of each individual indoor unit based on data communicated from indoor units and compared to the power consumption of an air conditioning installation with a standard setup. Note that P.P.D. is not a “ gauge” adapted to the methods of measuring power consumption in each country. All countries differ in the ways tenant billing systems are implemented depending on their respective legal systems. Data obtained by P.P.D. is for reference only and should not be used for official financial transactions.

Upload: others

Post on 11-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Basic Option PCN0410C - Tadmur Trading Intelligent T… · N et wo rk qu ipm n ,dI s v c. l b necessary to connect to the Internet. NEW Operation durations and the usage status of

Communication capabilities via a Web browser further expandair conditioning control possibilities.

Convenient controllers that offer more freedom to administrators.

Connectable to up to 128 Indoor unitsThe number of connectable indoor units can be doubled by adding an external adapter (Optional)

Control the Air Conditioning System from ElsewhereCentralized monitoring control system based on a Web browser (Optional)

Malfunction Reports to a Mobile Phone, AnywhereMalfunction reports delivered by e-mail (Optional)

Compatible with the 24-Hour Air Conditioning Network Service SystemBuilt-in modem for connecting to the Air Conditioning Network Service System (Optional)

Basic

Configuration and engineering for eachproject is necessary.

Hardwareintelligent Touch Controller

DSC601C5164 Groups

10

For further details, please consult your nearest Daikin Distributor or dealer.

Item

Model No.Max. indoor units

Max. outdoor units

Product data andengineering

Option

P.P.D.DCS002C51

——

Additional configuration and engineering for eachproject is necessary.

HardwareD -NET Plus Adaptor

DCS601A52+64 Groups

+10

SoftwareWeb

DCS004A51——

SpecificationNamePower supplyInstallation method condition for useOperating conditionDimensionsOverseascertification

LCD PanelCommunicationfunctionsInput terminals

Surrounding temperature/humidity(W × H × D)Safety of InformationTechnology EquipmentInterference (EMC)Size/no. of dots/no. of colorsD -NET ×110BASE-TDigital input Di ×1Pulse input Pi ×3

Externally supplied 100 V AC–240 V AC 50/60 HzJIS4 switchbox embedded in indoor wall0°C to 40°C/less than 85% RH (if no condensation)230 × 147 × 107 (mm)IEC60730 (including IEC60335)

EN55022 Class-A , EN550245.7 inches / QVGA 320 × 240 / 4096 colorsA/C equipment communication lineWeb optionForced Shutdown Power measuring pulse

Externally supplied 100 V AC–240 V AC 50/60 Hz —-10°C to +40°C/less than 90% RH157 × 190 × 42 (mm)IEC60730 (including IEC60335)

EN55022 Class-A , EN55024 —A/C equipment communication line — — Power measuring pulse

kWh meteritem

kWh meter Pulse transmitterRequirement Specification

•1 Pulse to 1 kW or 10 kW pulse width must be within 40–400 m/sec.•Output relay must be electronic type only. 1 Pulse to 1 kW or 10 kW pulse width must be within 40–400 m/sec.•No voltage output

intelligent Touch Controller (DCS601C51) D -NET Plus Adaptor (DCS601A52)

PCN0410C

Optional adaptersItemInputOutput

Installation method OperatingConditionPower supplyRated power consumptionApplied standardMass(Weight)Dimension

surrounding temperaturehumidity

8pairs based on a pair of On/Off input and abnormality input

indoor unstallation-10 to +40

10 to 85%AC200V-240V,50/60Hz

15W Safety standard : IEC730,EMC standard : CISPR22-A(EMI),CISPR(EMS)

2.5kg198(H) 335(W) 70(D)mm

4pairs based on a pair of On/Off input and abnormality inputIn case of normally output, 4 units are controllable.In case of instaneous output, 2 units are controllable.

Di unit (DEC101A51) Dio unit (DEC102A51)

All rights reservedPrinted in Japan 11/06/003 AD.HP.SWc

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

Printed on 100% recycled paper with soy ink.Specifications, designs and other content appearing in this brochure are current as of November 2006 but subject to change without notice.

ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the

About ISO 14001

ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the “ design, development, manufacture, installation, and supplementary service” of products manufactured at

About ISO9001

JMI-0107 JQA-1452 EC99J2044 JQA-E-90108

Trademark of American Soybeen AssociationPrinted on 100% recycled paper

Using lntelligent touch controller

1. Ins tallation of intelligent touc h c ontroller mus t be performed by a Daikin-trained engineer.

2. Onc e a month, adjus t the c loc k of the intelligent touc h c ontroller.

3. Daikin’ s unique P.P.D. s ys tem es timates the power c ons umption of eac h individual indoor unit bas ed on data c ommunic ated from indoor units and c ompared to the power c ons umption of an air c onditioning ins tallation with a s tandard s etup. Note that P.P.D. is not a “ gauge” adapted to the methods of meas uring power c ons umption in eac h c ountry. All c ountries differ in the ways tenant billing s ys tems are implemented depending on their res pec tive legal s ys tems . Data obtained by P.P.D. is for referenc e only and s hould not be us ed for offic ial financ ial trans ac tions .

Page 2: Basic Option PCN0410C - Tadmur Trading Intelligent T… · N et wo rk qu ipm n ,dI s v c. l b necessary to connect to the Internet. NEW Operation durations and the usage status of

Input (Lights)

Input (Key signal -General purpose ADP)

Dio UnitDEC102A51

Dio UnitDEC102A51

System

Set temperature change command OFF command

ACC center• Air Conditioning Network Service System

Pi Port

• Connection to power consumption meter when using power proportional distribution function. (Optional)

RS-232C

Publicphone line

Air Conditioning Network Service System modem for connections

• CSV output of power propor- tional distribution results (Optional)

PCMCIAFlash

Memory

Remote monitor-ing and control

Mobile Phone PC

Troublereports

The user-friendly controller already features colors, multilingual function, and icons in the display for ease of understanding; now, further convenience has been added. New communication capabilities enable centralized control via a Web browser and the sending of e-mail alerts on system operation. A wide variety of control methods can be accommodated, permitting administrators to monitor and operate the system even when they are away from the controller.

D -NET Plus AdapterDCS601A52(option)

Number of indoor unit expanded from 64 to 128.

D -NET

Function 1

Function 2 Function 3

Function 4

Function 5

Function 6

Support for centralized control from elsewhere using a PC with a Web browser (Optional)

Function 1

Sending of e-mail alerts to a specified address when malfunctions occur (Optional)

Function 2

Built-in modem for connecting to Air Condition-ing Network Service System (Optional)

Function 3

Doubling of number of connectable indoor units by adding a D -NET Plus Adapter (Optional)

Function 4

Management of facilities / equipment other than A/C units(By adding Dio unit or Di unit)

Function 5

Simple Interlock Function

Function 6

S ys te m C ompone nts

New communication functions in the user-friendly icon-based multilingual controller simplify centralized control of the VRV system.

1 2

Enhanced convenience through linkage to the Air Conditioning Network Service System

Mal-function

Air Conditioning Network Service System*

ACC center

Repair

Personnel at the center monitor the occurrence of malfunctions and track their causes via telephone lines. As soon as a problem occurs, expert service engineers are dispatched with precisely the tools and parts they need to make repairs.

Rapid repairs because service engineers know the cause of the problem before setting out.

Advance malfunction warnings help prevent the sudden occurrence of problems later.

C an be linked to the 24-hour Air C onditioning Network S ervic e S ys tem.

* There are restrictions in applicable areas and release times, therefore please consult us separately for details.

Malfunctions that can be difficult for children or elderly persons to understand are monitored remotely.

Allows dispatching of service engineers without the need for a call from the

customer.

intelligent Touch Controller

Indoor Unit HRV

Page 3: Basic Option PCN0410C - Tadmur Trading Intelligent T… · N et wo rk qu ipm n ,dI s v c. l b necessary to connect to the Internet. NEW Operation durations and the usage status of

Optional software

Using an Internet connection, multiple properties can be controlled from a single location.

PPD data can be accessedfrom remote place via internet.

PPD data used to be accessedin each building by PCMCIA card.

Pulse signal fromthe power meter

Pulse signal fromthe power meter

Pulse signal fromthe power meter

User-specific access restrictions

A controller that offers freedom to administrators.

Remote Monitoring of Multiple Properties

Ability to Control Air Conditioning Systems in Multiple Buildings from a Central Headquarters

PPD (Power Propotional Distribution)

Calculation of air conditioning costs and analysing usage trends(Option)

Availability of PPD data on web

web access function PPD function

3 4

Control and management are possible via the standard Web browser that comes installed on all PCs.

Main Monitoring Screen

User’s PC

HUB

Ethernet

Indoor unit Indoor unit Indoor unit HRV

It is possible to control the air conditioning system, via the Internet, from your home or any other location with a PC. Should a malfunction occur, a notification is sent by e-mail to a mobile phone or PC (e-mail address specified by the user). This gives administrators the freedom to leave the room where the controller is located.

•Special Software Is Not Required!

Notes1. Microsoft Internet Explorer 6.0 SP1, or a later version, is the recommended Web browser for use with the system.2. The J2SE V1.4.2 Java plug-in from Sun Microsystems is required.

Item

Real-time status monitoring

Operation

Malfunction history display

User password setting

Changing of language displayed

Func tions Us able with a Web B rows er

Internet*

Screen of user’s PCon fourth floor

Screen of administrator Head quarters office.

Note:The following items need to be set up, managed, and operated by yourself.1. Security

An environment that satisfies your security policy.2. Network

Equipment and settings that suit your network environment. A network security device such as a firewall which is necessary when connecting via the Internet.

3. The Internet connection is shown for illustration purposes only.Network equipment, and an Internet service provider contract, etc., will be necessary to connect to the Internet.

NEW

Operation durations and the usage status of individual indoor units are monitored, allowing for highly precise automatic power distribution analysis.

It is possible to access the PPD data of remote and multiple buildings, via internet, from any location with a PC web by the combination of Web access and PPD function. There is no necessity to go to the site, where the intelligent Touch controller is installed. Therefore it enables to simplify the management of electric power control.

Daikin’s exclusive PPD system* keeps track of power distribution for each indoor unit or any specifically designated area. It performs air conditioning billing calculations quickly and automatically.

*This measurement method is exclusive to Daikin and has no legal basis.

Operation durationPower consumptionAir supply temperatureExpansion valve opening

Operation informationof individual indoor units

Automatic calculation oftotal power consumption ofindividual indoor units

Pulse s

ignal

from

the po

wer mete

r

Power meter Total power consumption

Tenant A

Tenant B

Tenant C

Tenant AHIGH

Tenant BLOW

Tenant CMEDIUM

InvoiceInvoice InvoiceInvoice InvoiceInvoice

InvoiceInvoice

Internet

PCMCIAFlash

Memory

Availability of PPD data on web by the combination of Web access and PPD function

Page 4: Basic Option PCN0410C - Tadmur Trading Intelligent T… · N et wo rk qu ipm n ,dI s v c. l b necessary to connect to the Internet. NEW Operation durations and the usage status of

Security

Control and Monitoring Functions Control and Monitoring Functions

Registering Passwords

With jus t two or three s imple ac tions , you c an s pec ify the Air C onditioner you want and c ontrol it with the utmos t s peed

Ic on Display

Displayc hange

List Display

S elec tion of ic on orlis t display

S elec tion of zone orgroup display

ON/OFF settings for selec ted groups and/or zones

C omplete display of the c ondition of all Air C onditioners

Display of zone name

Various ic ons that you c an set yourself

Displays c urrent date and timeDisplays system c ondition

(forc ed shutdown, etc .)

C an display detailed legend

Allows you to set the name of the individual unit

Allows eas y operation of a variety of func tionsinc luding the s etting of operation mode andtemperature

The us er c an s witc h between the ic on dis play, a lis t dis play, and an ic on detail dis play as des ired.

S etting of operation mode ac c ording to respec tive purpose

Temperature setting ac c ording to respec tive purpose

Displays detailed Air C onditioner information/data

S c reen related to advanc ed operation (seldom-used sc reen)

An often-used operation sc reen

ON/OFF of all Air C onditionersColor LCD

Screen

Touch ScreenOperation

IconDisplay

2 Selection by touch1 Page Up/Down

E nglish Frenc h Italian S panishG erman C hinese

Passwords for general users and for administrators can be registered separately, permitting access to different levels of control functions.

Multiple Languages

The display language can be switched as desired (Eng-lish, French, German, Italian, Spanish and Chinese). By displaying text in the admin-istrator’s own language, ease of use is enhanced.

Enhanced legibility and ease of use, plus expanded control functions.

Ic on Detail Display

5 6

Auto Heat/Cool Change-over Temperature Limitation

This function allows the optimal room temperature to be maintained without users having to change the operation mode by automatically switching the air conditioner’s operation mode (cooling or heating) ac-cording to the room temperature for locations where the temperature difference during the day and at night is very large.

This function automatically starts and stops air conditioners in order to prevent the room temperature of unoccupied rooms from getting too high or too low.

°C

CoolingSetpoint

HeatingSetPoint

Heating

Heating

Cooling

HeatingCooling

Heating

Time

Cooling

Temp Difference Change Set Point

Change Set Point

RoomTemp

Max

Start HeatingStop Heating

Time

Stop Cooling

Min

Min+4°C

Max4°C

Room Temperature is maintained withinthe range

HeatingMode

CoolingMode

Start Cooling

Enhanced Scheduling Function

Simple Interlock Function Added

Enhanced History Function

It is possible to set up an automated yearly schedule specifying such items as daily startup and shutoff times, temperature settings, and oper-ation modes. In addition, the number of patterns that can be registered has been increased from seven to ten.

Changing Display Colors

The color of the icons indicating running and stopped status can be changed. This makes it easy to customise the display to match the ad-ministrator’s preferences or match the display of other control devices.

The simple interlock function allows for controlling of multiple groups and zones based on the operation status of the selected groups or zones.

The error history function keeps a detailed record broken down by mal-function item. This is an important feature for maintaining the system and dealing with malfunctions, and it helps realize that appropriate main-tenance work is performed.

Calendar Screen

Input (Lights)

Input (Key signal)

Dio UnitDEC102A51

Dio UnitDEC102A51

Set temperature change commandOFF command

Note: Colours showncan be changed.

R un S top E rror C om.E rror Maintain