baseboards & radiators - republic plumbing supply co. & radiators cast iron heat...

4
Baseboards & Radiators Cast iron heat distribution for water and steam heating systems Rugged cast iron can provide years of reliable service • Will not bend, dent, or separate, even after years of service • Sectional design • Extremely quiet, typical expansion noises associated with thin-metal type radiant heat products are virtually eliminated • Variety of styles available, can fit into any application • Can be painted to match room decor • Ideal replacement products for existing radiators Baseray ® baseboards Slenderized radiators Radiant radiators Classic radiators

Upload: phamkhanh

Post on 30-Mar-2018

225 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Baseboards & Radiators - Republic Plumbing Supply Co. & Radiators Cast iron heat distribution for water and steam heating systems • Rugged cast iron can provide years of reliable

Baseboards& RadiatorsCast iron heat distribution for water and steam heating systems

• Ruggedcastironcanprovideyearsof reliableservice

• Willnotbend,dent,orseparate,evenafter yearsofservice

• Sectionaldesign

• Extremelyquiet,typicalexpansionnoises associatedwiththin-metaltyperadiantheat productsarevirtuallyeliminated

• Varietyofstylesavailable,canfitinto anyapplication

• Canbepaintedtomatchroomdecor

• Idealreplacementproductsforexisting radiators

• Baseray®baseboards

• Slenderizedradiators

• Radiantradiators

• Classic™radiators

Page 2: Baseboards & Radiators - Republic Plumbing Supply Co. & Radiators Cast iron heat distribution for water and steam heating systems • Rugged cast iron can provide years of reliable

Baseray®BaseboardInformation, Specifications, & Dimensions

1.Fins2.TieBolt3.PushNipple

A B C D E F G1” 7/8” 2-1/2” 9-7/8” 1-3/4” 1-3/4” 3/4”

Useofthe2,000Lb./Hr.ratingsislimitedtoinstallationswheretheflowratethroughthebaseboardunitisequaltoorgreaterthan2,000Lb./Hr.(4GPM).WherethewaterflowratethroughtheBaserayisnotknown,theratingsatthestandardflowrateof500Lb./Hr.(1GPM)mustbeused.NetAHRIRatingsaredeterminedfromtestsmadeinaccordancewiththeAHRITestingandRatingCodeforbaseboardtyperadiation,includinganallowanceof15%forheatingeffectpermittedbytheCode.Maximumallowableworkingpressure-30PSI,water;15PSI,steam.Watercontent-0.3gal./linealfoot.Forpressuredropinformation,seeinstallationmanual.Ratingsarebasedonactivelength.Activelengthequalstotallength.

NOTES:Availableinanylengthwithsimilarsub-assemblies.Maximumrecommendedlengthforsteam:10Ft.

ASSEMBLY LENGTH L.H. CENTER R.H.

6-1/2Ft. 5-1/2Ft. — 1Ft.7Ft. 6Ft. — 1Ft.7-1/2Ft. 5-1/2Ft. — 2Ft.8Ft. 6Ft. — 2Ft.8-1/2Ft. 5-1/2Ft. — 3Ft.9Ft. 6Ft. — 3Ft.9-1/2Ft. 5-1/2Ft. — 4Ft.10Ft. 6Ft. — 4Ft.10-1/2Ft. 5-1/2Ft. — 5Ft.11Ft. 6Ft. — 5Ft.11-1/2Ft. 5-1/2Ft. — 6Ft.12Ft. 6Ft. — 6Ft.12-1/2Ft. 5-1/2Ft. 6Ft. 1Ft.13Ft. 6Ft. 6Ft. 1Ft.

ASSEMBLIES 18” Left End

24” Left End

24” Int.

24” Right End

12” Right End

18”Panel

24” Panel

1-1/2Ft.Assembly — — — — — 1 —2Ft.Assembly — — — — — — 12-1/2Ft.Assembly 1 — — — 1 — —3Ft.Assembly — 1 — — 1 — —3-1/2Ft.Assembly 1 — — 1 — — —4Ft.Assembly — 1 — 1 — — —

4-1/2Ft.Assembly 1 — 1 — 1 — —

5Ft.Assembly — 1 1 — 1 — —5-1/2Ft.Assembly 1 — 1 1 — — —

6Ft.Assembly — 1 1 1 — — —

SUB-ASSEMBLIES

5-1/2Ft.L.H.Sub-Assembly 1 — 2 — — — —

6Ft.L.H.Sub-Assembly — 1 2 — — — —

6Ft.CenterSub-Assembly — — 3 — — — —

AllR.H.Sub-Assemblies — —Req’d#1or1 — —

BASERAYRATINGS SteamandHotWater

BASERAYDIMENSIONS

Designedwithperformanceanddependabilityinmind,BaserayBaseboardsofferasleek,lowprofiledesignthatwillfitinwellwithvirtuallyanyroomdecor.Unlikemostbaseboards,Baseraycanalsobepainted,providingaseamlessmatchtoitssurroundings.

Thesimple,yeteffectivedesignoftheBaserayprovidesmorethanfivetimestheamountofradiantheattoaroom.Thisisduetothefactthatthecastironsurfaceareaismuchlargerthanthatfoundon

conventionalthinmetalbaseboards,andthatheatcanbedistributedbothinhorizontalANDverticaldirection.Thisleadstouniform,evenheatdistributionintheroom,andlessthana2-degreedifferencebetweenfloorandceiling.

EachsectionofBaserayBaseboardsfeatureone-piececastironconstruction.Thisdesignvirtuallyeliminatestheexpansionnoisescreatedduringheatingcyclesandisbuilttolastmuchlongerthanconventionalfabricatedbaseboards.

MODEL NO.

APPROX WT (lbs. Per Linear Foot)

FLOW RATE

NET AHRISTEAM RATING

NET AHRI WATER RATINGS BTUH Per Linear Foot At AverageWater Temperatures Indicated

9A 15Lb./Hr. Sq.Ft. BTU/Hr.

At215°F150°F 160°F 170°F 180°F 190°F 200°F 210°F 220°F 230°F

2000 3.40 860 340 390 450 510 560 610 670 720 770500 3.40 860 320 370 430 480 530 580 630 680 730

Page 3: Baseboards & Radiators - Republic Plumbing Supply Co. & Radiators Cast iron heat distribution for water and steam heating systems • Rugged cast iron can provide years of reliable

Baseray®BaseboardInformation, Specifications, & Dimensions

Classic™RadiatorsInformation, Specifications, & Dimensions

*Equivalenceofdirectradiationofheatingsurfacebaseduponthestandardheatemissionof240BTUpersquarefootperhour.

Stocksizesavailableforimmediateshipment.Assemble5sectionintermediatewith3,5,7or9sectionstocksizetomakeacustomsize.Endsectionwithventisalsousedasintermediatelegsupportforradiatorswithmorethan16sections.WaterContent—0.61gal/section.Outputbasedonroomtemperatureof70°F.Maximumrecommendedpressure58psiwater,15psisteam.Specialtoolrequiredfordisassembly/assembly.Ratingsquareft./section=3.05

MODEL NO.

NUMBER OF SECTIONS

(3.07” each)A-WIDTH (inches)

SQUARE FEET

(EDR*)

WATER OUTPUTBTU/H

(180°F avg. temp.)

STEAM OUTPUTBTU/H

(215°F avg. temp.)

SHIPPINGWEIGHT

(lbs.)CR-3-CFCR-5-CFCR-7-CFCR-9-CFCR-5-AF8074011

3579

5-IntermediateEndsectionw/vent

9.215.421.527.615.43.1

9.215.321.427.515.33.1

15642618365546922618524

22083672513666003672734

7712917722612926

Fortheultimateinreplacementradiators,especiallyinperiod-homerenovationprojects,looknofurtherthanBurnhamClassicRadiators.Providingefficientheattransferandthetimelessstylingofabygoneera,theseelegantradiatorsareinaclassbythemselves.

AllClassicRadiatorsfeaturedurablecastironconstructionwithornatesurfacedetail.Tocompletetheappearance,brassvalvesarealsoavailable

Castironprovidesveryquietoperation,asthetypicalexpansionnoisesassociatedwithotherradiatorsareeliminated.Theheatretentionpropertiesofcastironalsoprovidetheabilitytoshieldoutsidewallsandwindowstostopcoldairinfiltration.

RadiantRadiatorsInformation, Specifications, & Dimensions

*Venttappingsizes;highventsforwater,mid-heightventsforonepipesteam

A B C D E F G*

5” 20” 2-3/4” 4-1/2” 1-7/8” 1-1/4” 1/8”

NPT NPT

*Increaseradiatorsize10%whenrecessed.

Heatingsurfacebaseduponthestandardheatemissionof240BTUpersquarefootperhour.Furnishedinevennumberofsectionsupto44sections.Maximumallowableworkingpres-sure-30PSI,water;15PSI,steam.Watercontent-0.15Gal./section

Size - Number of Sections

Length2-1/4” per

Section (inches)

Free Standing EDR*, Square

Feet per Section 2.25

468101214161820222426283032343638404244

9”13-1/2”18”

22-1/2”27”

31-1/2”36”

40-1/2”45”

49-1/2”54”

58-1/2”63”

67-1/2”72”

76-1/2”81”

85-1/2”90”

94-1/2”99”

9.013.518.022.527.031.536.040.545.049.554.058.563.067.572.076.581.085.590.094.599.0

RADIANTRADIATORRATINGS

RadiantRadiatorscanbeusedasreplacementrecessedradiatorsforcabinetsandotherinteriorstructures,orasstandaloneheatdistributors.

Designedtodrawcoolairinthroughthebottomandprojectwarmairoutthroughthetopports,radiantradiatorsfeaturedurablecastironconstructionandsectionaldesign.Theseproductsofferveryquietoperation,asthetypicalnoisesassociatedwithothertypesoffabricatedradiatorsareeliminated.

RADIANTRADIATORDIMENSIONS

Page 4: Baseboards & Radiators - Republic Plumbing Supply Co. & Radiators Cast iron heat distribution for water and steam heating systems • Rugged cast iron can provide years of reliable

©2013U.S.BoilerCompany,Inc.-Lancaster,PAPhone:1-888-432-8887

USBL130252.5mwwww.usboiler.net

SlenderizedRadiatorsInformation, Specifications, & Dimensions

Centerlegsectionfurnishedon30sectionandbetter*Heatingsurfacebaseduponthestandardheatemissionof 240BTUpersquarefootperhour. Add1/2”foreachbushing.Furnishedinevennumbersectionupto48sections.Maximumallowableworkingpressure-50PSI,water;15PSIsteam.Consultfactoryforhigherpressure.Watercontent-19-4:0.08Gal./section;25-4:0.12Gal./section;26-6:0.17Gal./section

SizeNo. of

Sections

Length1-3/4” per Sections (inches)

Square Feet - EDR*4-Tube 6-Tube

19” High 25” High 25” High4681012141618202224262830323436384042444648

7”10-1/2”14”

17-1/2”21”

24-1/2”28”

31-1/2”35”

38-1/2”42”

45-1/2”49”

52-1/2”56”

59-1/2”63”

66-1/2”70”

73-1/2”77”

80-1/2”84”

6.49.612.816.019.222.425.628.832.035.238.441.644.848.051.254.457.660.864.067.270.473.676.8

812162024283236404448525660646872768084889296

121824303642485460667278849096102108114120126132138144

Size H I J K L M N O

25-625-419-4

23-13/16”23-13/16”17-13/16”

6-15/16”4-7/16”4-7/16”

1-1/16”1-1/16”1-1/16”

1”1”1”

1/8”1/8”1/8”

21-7/16”21-7/16”15-7/16”

1-1/4”1-1/4”1-1/4”

2-1/2”2-1/2”2-1/2”

NPT NPT NPT

SLENDERIZEDRADIATORDIMENSIONS

SlenderizedRadiatorsprovideheatinalowprofilepackage.Lowerandslimmerthanmostconventionalradiators,theyfeaturearuggedandreliablecastironsectionaldesignwhicheasilyenablestheinstallationofmultipleunits.

Obsoletesizes–AllTypesBurnhamRadiantRadiators Federal-OldStyleColumnRadiation

Fero-2-1/2”center

RATING - Square Feet Per Section

Height

1Col.2-1/2”ctr.

2Col.2-1/2”ctr.

3Col.2-1/2”ctr.

4Col.3”ctr.

5Col.3”ctr.

14”17”18”20”22”23”26”32”38”44”45”

———1.50—1.672.002.503.00——

———2.00—2.332.673.334.00—5.00

——2.25—3.00—3.754.505.00—6.00

——3.00—4.00—5.006.508.0010.00—

4.004.005.005.006.00——————

Height

RATING - Square Feet Per Section

3Tube 4Tube 5Tube 6Tube 7Tube

14”17”20”23”26”32”38”

——1.752.002.333.003.50

——2.252.502.753.504.25

——2.673.003.504.335.00

——3.003.504.005.006.00

2.673.253.67—4.755.506.75

23X7-1/23.40sq.ft.persec.

Wall2.25sq.ft.persec.

RATING - Square Feet Per Section

Height

3Tube 4Tube 5Tube 6Tube

1-1/2”ctr.

1-3/4”ctr.

1-1/2”ctr.

1-3/4”ctr.

1-1/2”ctr.

1-3/4”ctr.

1-1/2”ctr.

1-3/4”ctr.

14”17”19”20”22”23”25”26”32”

——1.10—1.30—1.50——

——————1.60——

——1.40—1.60—1.80——

————1.80————

———1.80—2.10—2.403.00

————2.10—2.40—3.00

1.501.80—2.20———2.90—

1.602.002.30—————3.70

BurnhamSlenderized

RecommendedSystemPipingONE-PIPESTEAMUpto28sq.ft.................................................. 1inchUpto62sq.ft.................................................. 1-1/4inches

HOTWATER-Two-PipeForcedCirculation Upto100sq.ft............................ 1/2inch 101sq.ft.andlarger.................... 3/4inch

HOTWATER-TWO-PIPEGRAVITYSYSTEMFirstfloor-Upto20sq.ft................................ 1/2inch 21to50sq.ft............................... 3/4inch 51to100sq.ft............................. 1inch 101to175sq.ft........................... 1-1/4inchSecondfloor-Upto30sq.ft........................... 1/2inch 31to70sq.ft............................... 3/4inch 71to120sq.ft............................ 1inch 121to250sq.ft........................... 11/4inchThirdfloor-Upto40sq.ft.............................. 1/2inch 41to100sq.ft............................ 3/4inch 101to175sq.ft.......................... 1inch 175to300sq.ft.......................... 1-3/4inch

*Plug +Alternate

A B C D E

OnePipeSteam * supply +vent vent *TwoPipeSteam suppiy +supply * * return

HotWater * supply vent * return

NOTES:Allsizesbasedonsteelpipe.Vaportappings,topandbottomoppositeends;supply3/4inch,return1/2inch.

Fortappingsonone-pipehotwatersystemsseeAHRIInstallationGuide.Thelastconnectiontakenoffthemainshouldberuntoafirstfloorradiator.Radiatorsinwhichmainsterminateshouldhaveonesizelargervalves.

Heat Emission Chart (70°F room temp)

Avg.watertempin

radiators,°F

Heatemission

BTU/Hr.persq.ft.

150160170180190200210215

110130150170190210230240