automatic blood components extractor New 2010 versions: RFID, Wi-Fi and Ethernet ready! picture of GIOTTO cod. GIO.DB.XXX.P2) It works with any conventional or T&B bags Two electronic presses fully controlled for speed, position and force Automatic air removal procedures Fine buffy-coat controls while using T&B bags Flow regulator with high precision optical sensor Five sealing clamps 16 pre-loaded Procedures Up to five scales RFID writer-reader and barcode On-line tubes control with led’s aid panel Wi-Fi, Ethernet or RS485 communication mode automatic blood components extractor

Upload: others

Post on 31-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

  • automatic blood components extractorautomatic blood components extractor

    New 2010 versions: RFID, Wi-Fi

    and Ethernet ready!

    picture of GIOTTO cod. GIO.DB.XXX.P2)

    It works with any conventional or T&B bags Two electronic presses fully controlled for speed,

    position and force Automatic air removal procedures Fine buffy-coat controls while using T&B bags Flow regulator with high precision optical sensor Five sealing clamps 16 pre-loaded Procedures Up to five scales RFID writer-reader and barcode On-line tubes control with led’s aid panel Wi-Fi, Ethernet or RS485 communication mode

    a u t o m a t i c b l o o d c o m p o n e n t s e x t r a c t o r

  • automatic blood components extractor

    GIOTTO is a automatic extractor designed to prepare blood components from centrifuged blood in single use plastic bags manufactured upon the International Standard ISO 3826 and the European Directives no. 93/42 and 2007/47 MDD. It can prepare high quality blood components with any kind of commercially available bag, either conventional or TOP & BOTTOM type. GIOTTO is available in two main versions, basic and with double press, each with different configuration for computer connection.

    Electronic main press with integrated scale fully controlled for speed, generated force and position.

    Secondary press with integrated scale and same controls of main press (only with GIOTTO code GIO.DB.00.P2X).

    Five programmable sealing clamps.

    External sealing gun available as option.

    Flow regulator with auto-zeroing optical sensor.

    Eight optical sensors on main press for fine control of BC volume and haematocrit.

    Three scales to read the net weights of all components (four with version GIO.DB.XXX.P2) plus one external as option.

    Communication mode available as RS485, Wi-Fi or Ethernet (see versions of GIOTTO available).

    Barcode reader or COMBO RFID Tags reader-writer with integrated barcode (options).

    Graphic LCD Display white-blue back lighted with guided menu and membrane keyboard.

    16 pre-loaded Programs as standard. Up to fifty additional PROGRAMS can be generated and stored by using the dedicated SDM software.

    Automatic air removal and additive solution transfer available as standard routine.

    GIOTTO can read automatically all weights of components or, at the end of each extraction can weight up to five different bags as net or gross weight and thus record all data (after or before tubing disconnection).

    mAIN PRESS Electronically controlled with two movements type: parallel or with exclusive angled plate movement. Wide controls on whole stroke. Possibility to generate up to five independent speed-pressure profiles with controls on pressures, speeds, position, feedback with optical sensors for best handling of BC layer and phase time out for each Program.

    QUALITY AND SAFETY

    All optical sensors perform automatically a auto-calibration to zero at any new separation.

    Dynamic LEDs indicators for correct tubes positioning showing the clamps to use, actives all separation long.

    Precise control of final buffy-coat volume with fine adjustment of haematocrit while using top and bottom bags.

    ● = active sensor to hold on the BC levelD* = distance to define precisely the desired final volume

    D*

    RBC

    BC

    PL

    D*D*

    RBC

    BC

    PL

    D*

    a u t o m a t i c b l o o d c o m p o n e n t s e x t r a c t o r

    Example of bag label printed by option code GIO.DB.90

  • automatic blood components extractorpicture of GIOTTO cod. . GIO.DB.XXX.P2

    Vertical scale with adjustable highness

    TOP sealing clamps

    Active clamps panel

    Right hand scale

    Optional tray scale GIO.DB.40

    BOTTOM sealing clamp

    Optional sealing handgun GIO.DB.50

    Lateral press with scale

    Press 1 scale

    Main press with BC optical sensors group

    TOP optical sensor (with lighting head status)

    Flow regulator & sealer

  • automatic blood components extractorautomatic blood components extractor

    FLEXIBILITY • 16 pre-loaded extraction Programs with most common

    applications for double, triple, quadruple and quintuple conventional and Top & Bottom bags. Possibility to expand the list up to 50 Programs.

    • Up to five integrated scales for automatic weighting and recording of all blood preparations.

    • Five programmable welding clamps for manual or automatic operation: available as option a sixth mobile sealing gun.

    • Air removal routine available as standard.

    • Secondary press available to perform most complex procedures rapidly and precisely: filter priming, air removal from plasma bag, fast SAG-M transferring (only with versions GIO.DB.XXX.P2).

    GIOTTO can deliver several information to SDm for each extraction procedure:

    1. Serial number of GIOTTO 2. Description of the performed Program 3. Number of the performed Program 4. Net weight of Plasma extracted 5. Net weight of Buffy Coat 6. Net weight of whole blood 7. Net weight of Plasma transferred into BC bag 8. Net weight of transferred SAG-M 9. Net weight of PL transferred back into the main bag

    10. Net weight of PL extracted into other satellite bags 11. Net weigh of Platelets Concentrate 12. Net weight of packed RBC 13. Separation date 14. Time of separation 15. Duration of separation 16. Error codes if any 17. Tens of different and customizable codes,

    either as barcode labels or RFID Tags are available too

    DATA mANAGEmENT AND COmPUTER SDM-Software Data Management is a specific application designed for remote controls of GIOTTO and for collection & handling of separation data. SDM should be installed on a computer with Windows® XP, VISTA or 7 (computer and Microsoft® software not included). To communicate with the available GIOTTO, SDM may use RS485, Wi-Fi or Ethernet connections. By using SDM you can do the following remote operations on all GIOTTO connected to the net:

    • modify any Programs available on each GIOTTO• generate new Programs of separation• download the data of each single extraction procedure done by

    GIOTTO• remotely set the Program to be used on one or more separators• generate Reports based on the executed extraction procedures

    applying for customizable filters to fit the minimal quality standards of the blood bank. The Reports can be printed directly through the pre-defined printer of computer or saved as .csv or Word file (may requires Microsoft Office® on computer)

    • By using the optional printer label (see options) it is possible to prepare customizable adhesive labels to be populated with net or gross weights, ID bags, ID Operator and some more

    COmmUNICATION AND TRACEABILITY • Communication mode via RS485,

    Wi-Fi or Ethernet.

    • Codes handling can be done either as barcode labels or RFID Tags.

    • Cross-matching of each code by customized filters and/or fixed masks.

    • Internal data base with automatic LOG saving for all operations and extraction procedures.

    Barcode

    R FID Tags

  • automatic blood components extractorautomatic blood components extractor

    LAYOUT AND ACCESSORIES FOR COmPUTER CONNECTION:

    Option 1: RS485-RS232 CONNECTION

    Needed parts for RS485-232 connection: (1) Code GIO.DB.311 network adapter: buy one

    for each computer where SDM will be installed.

    Option 3: Wi-Fi CONNECTION

    Needed parts for ethernet connection: (3) Code GIO.DB.WIFI_AP WiFi access point already

    configured: buy one for each computer.

    Option 2: ETHERNET CONNECTION

    Needed parts for ethernet connection: (2) Code GIO.DB.HUB_PC Ethernet Switch (HUB):

    buy one for each computer.

    a u t o m a t i c b l o o d c o m p o n e n t s e x t r a c t o r

    ORDERING INFORmATION - Available versions of GIOTTO

    GIOTTO - Automatic blood components extractor: versions with MAIN press only.

    Cod. GIO.DB.485 - GIOTTO configured for RS485 connection. Includes one serial Net cable. It may request a Network adapter cod. GIO.DB.311 (see accessories for computer).

    Cod. GIO.DB.LAN - GIOTTO configured for Ethernet connection. Includes one internal Ethernet module and one Ethernet cable. It may request a Ethernet Switch cod. GIO.DB.HUB_PC (see accessories for computer).

    Cod. GIO.DB.WiFi - GIOTTO configured for Wi-Fi connection. Includes one internal Wi-Fi module. It may request a Wi-Fi Access point cod. GIO.DB.WIFI_AP (see accessories for computer).

    GIOTTO - Automatic blood components extractor: versions with TWO presses.

    Cod. GIO.DB.485.P2 - GIOTTO double press configured for RS485 connection. Includes one serial Net cable. It may request a Network adapter cod. GIO.DB.311 (see accessories for computer).

    Cod. GIO.DB.LAN.P2 - GIOTTO double press configured for Ethernet connection. Includes one internal Ethernet module and one Ethernet cable. It may request a Ethernet Switch cod. GIO.DB.HUB_PC (see accessories for computer).

    Cod. GIO.DB.WiFi.P2 - GIOTTO double press configured for Wi-Fi connection. Includes one internal Wi-Fi module. It may request a Wi-Fi Access point cod. GIO.DB.WIFI_AP (see accessories for computer).

    Network Adapter

    (1)

    (2)

    (3 )

    Computer with SDM installed

    Computer with SDM installed

    USB port

    RS232/COM

    Ethernet switch

    Wireless Access point

    GIOTTORS485 Module

    GIOTTOEthernet Module

    GIOTTOWiFi

    Module

    GIOTTORS485 Module

    GIOTTOEthernet Module

    GIOTTOWiFi

    Module

    GIOTTORS485 Module

    GIOTTOEthernet Module

    GIOTTOWiFi

    Module

    Computer with SDM installed

    Ethernet port

    Ethernet port

  • automatic blood components extractorautomatic blood components extractor

    a u t o m a t i c b l o o d c o m p o n e n t s e x t r a c t o r

    Cod. GIO.DB.40 External balance with tray. To be connected directly to GIOTTO with a cable. It can be used to read the weight of any bag, before, during or after the separation.

    Cod. GIO.DB.50 Sealing handgun with cable. Supplied with a 2 m lead cable it is connected directly to the auxiliary RF port of GIOTTO. It permits the manual sealing of any standard PVC tubing of bags. It can be purchased and added at any time.

    Cod. GIO.DB.60 CCD barcode reader. It can be purchased and added at any time (buy one for each GIOTTO). ORCod. GIO.DB.60L LASER barcode reader. It can be purchased and added at any time (buy one for each GIOTTO).

    Cod. GIO.DB.80 COMBO CCD barcode reader and RFID reader and writer for Tags ISO15693 and 18000-3. It can be purchased and added at any time.(buy one for each GIOTTO).ORCod. GIO.DB.80L COMBO LASER barcode reader and RFID reader and writer for Tags ISO15693 and 18000-3. It can be purchased and added at any time (buy one for each GIOTTO).Cod. STR.DB.00 Manual tube stripper.

    Cod. GIO.DB.90 Printer for adhesive labels. To be used to report on the bags some data such as the product type, the net or gross weight, the ID of the bag.

    Distributed by:

    SEPARATE OPTIONAL ACCESSORIES:

    The

    spec

    ifica

    tion

    can

    be c

    hang

    e w

    ithou

    t not

    ice

    - R

    ev.0

    1 -

    2010

    makelab

    .itTECHNICAL DATATrade name GIOTTO

    Manufacturers DELCON srl, Arcore (MB) Italy

    Destination of use To prepare blood components from centrifuged whole blood in single use plastic bags

    Class of electrical protection

    1 Type B

    CE mark Class 1 Medical Device (93/42 and 2007/47 MDD)

    Reference Standards EN 60601-1 and EN 60601-1-2

    Mean separation time 1.30 minutes for a conventional quadruple bag2.30 minutes for a T&B quadruple bag

    Alarms and notice Optical and audible with notice on the display

    Power supply 115/230 VAC-50/60Hz single phase phase +/- 10%

    Power consumption 330 VA

    Fuses 2 x 1,6 A-230 V Type T2 x 2,5 A-115 V Type T

    Using conditions Ambient temperature between +10 °C to +35 °CMax allowed humidity 85% RH without condensation

    Storage conditions +10 °C/+40°C without condensing humidity

    Dimensions 400H x 330W x 400D mm (add +250H for the vertical rod of the balance)

    Net Weight 33-38 kg

    Gross weight: 45-50 kg

    Package size: 560H x 520W x 500D mm