DESCRIPTION
ASDUZA-A-РP - an automated hardware system designed for remote control for isolation valves with nominal diameter of 50 up to 1200 mm. There is the autonomous telematics complex "Soft:Signal" in explosion-proof version with the ability of pneumatic control drive GBVA/DAPS Festo-powered DC voltage 24V in the system.TRANSCRIPT
ASDUZA-A-РP - an automated hardware system designed for remote control for isolation valves with nominal
diameter of 50 up to 1200 mm. There is the autonomous telematics complex "Soft:Signal" in explosion-proof version
with the ability of pneumatic control drive GBVA/DAPS Festo-powered DC voltage 24V in the system.
The complex is completely self-contained and can be
operated at explosion-hazardous sites without mains
power supply of 220/380V. Autonomous power supply
system is developed on solar cells that generate
electricity and charge batteries. The stored energy is
consumed by telemetering system and control of the
pneumatic drive.The effectiveness of this method is in renewing
energy system, which allows on-line monitoring of the
object to improve the reliability of Executive mechanisms.The control of isolation valves and transfer of process
parameters of the facility is performed via wireless GSM/
GPRS channel. Iridium/Gonets satellite data transmission
system is used as a redundant channel. The system can
effectively function on the areas with unstable GSM signal
or out of coverage.The natural gas flowing in a pipe, as well as
compressed air, received in the result set in the complex
of the compressor can serve as the working body for
pneumatic actuator. The working pressure of the actuator
is 2.5 ... 8 bar (Max. pressure 413 bar). This principle
allows reducing expenses for maintenance of the complex
due to the automated regeneration of gas for the actuator
control.
OPERATING ENVIRONMENT SYSTEM:
The system conform to the type of climatic performance
of UHL and location category 1 by GOST 15150
The system is intended for installation in hazardous
production facilities in accordance with the requirements of
norms and rules of industrial safety, and also according to
requirements of Chapter 7.3 of PUE (seventh edition), and
other normative-technical documents regulating the use of
equipment in potentially explosive areas
The complex meets the requirements of the normative
document "Gas Distribution systems. Standard technical
solutions for automation of technological equipment" P
Gazprom 2-1.17-586-2011
The capacity of the compressor
The receiver volume
Working pressure system
200 W
20..80 liters
4..6
www.rosteleservice.com [email protected] +7-800-250-01-04
INNOVATIONS OF YOUR BUSINESS
since 2004
AUTOMATED VALVING REMOTE CONTROL SYSTEM
АSDUZА-A-PPINNOVATIONS OF YOUR BUSINESS
since 2004
AUTOMATED VALVING REMOTE CONTROL SYSTEM
АSDUZА-A-PP
Emergency or planned opening / closing of isolation
valves on the facility upon command by operator or in
case of emergency readings of the system sensors
Collection, analysis, storage and transfer of process
parameters of the facility to the control room via wireless
communication channels
Facility perimeter guarding and control for opening
the cabinets with equipment, access control – the system
«friend/foe», instant notification of ADS about the
unauthorized access
SYSTEM FUNCTION:
APPLICATION SYSTEM:
Block valve stations of gas distribution and gas
transmission networks;
Block valve stations for oil transportation, storage
and reforming;
Ball valves up to and /or after gas distributing
plants;
Locking devices on the unguarded facilities that
are hard to access;
Block valve stations before dead-ended and
loopback gas distribution units;
Gas-fired heat generations and boiler rooms.
TECHNICAL SPECIFICATIONS:
General
Overall dimensions
Operating temperature range
Ingress protection rating
880х800х400mm (foundation - 720 mm)
100 kgWeight
-40°С.. +85°С
IР67
Solar-battery powerto be chosen depending on operating conditions: 65 W/ 150 W/ 250 W
Independent power supply, battery 24V, 27 А*h
Wireless data transmission and control channels
Redundant channel
Main channelGSM 900/1800 GPRS/CSD/SMS +redundant channel GSM (integrated)
«Iridium»/«Gonets» satellite channel
3. Ambient temperature
4. Gas/liquid temperature on Block valve station
1. Excessive gas/liquid pressure to Block valve station
2. Excessive gas/liquid pressure after Block valve station
5. Gas contamination (methane, carbon monoxide) on Block valve station
6. Isolation valve position (open/closed)
7. Continuity signal of actuator's control circuits
8. Location of doors in process room and cabinet
9. Guard condition of the Block valve station perimeter
10. Facility service signal
11. The status of self-contained power supply system (battery charge, solar battery performance control)
12. Signal intensity on main and redundant communication channel
Process parameters of the facility
Control system characteristics of driver
Driver's supply voltage
Max. starting current
Q-ty of connectable drivers with direct control
Q-ty of cycles for opening/closing with complete charge of battery
24V
2
Up to 120 cycles
Up to 16 А
SatelliteGonets
Ground-based radar Iridium
Pipeline
Pneumatic drive
with shutter
ASDUZA
Drive control system
AKB
GSM Iridium
Valv
e p
ositio
n
Control
Batt
ery
serv
ice life
Charg
e
Internet
E-m
ail
Internet
Redunda
nt
chan
nel
Main channel
ТСР
E-m
ail
CCR
ARM
Solar battery
Server telemetry
Data base
RS-485ТСР
Redundant
channel
Redundant
channel
Вase station
Switching unit
Satellitetransmitter
Management of electro-pneumo-
valve
The system of preparation
of air
www.rosteleservice.com [email protected] +7-800-250-01-04
ASDUZA-A-РP - an automated hardware system designed for remote control for isolation valves with nominal
diameter of 50 up to 1200 mm. There is the autonomous telematics complex "Soft:Signal" in explosion-proof version
with the ability of pneumatic control drive GBVA/DAPS Festo-powered DC voltage 24V in the system.
The complex is completely self-contained and can be
operated at explosion-hazardous sites without mains
power supply of 220/380V. Autonomous power supply
system is developed on solar cells that generate
electricity and charge batteries. The stored energy is
consumed by telemetering system and control of the
pneumatic drive.The effectiveness of this method is in renewing
energy system, which allows on-line monitoring of the
object to improve the reliability of Executive mechanisms.The control of isolation valves and transfer of process
parameters of the facility is performed via wireless GSM/
GPRS channel. Iridium/Gonets satellite data transmission
system is used as a redundant channel. The system can
effectively function on the areas with unstable GSM signal
or out of coverage.The natural gas flowing in a pipe, as well as
compressed air, received in the result set in the complex
of the compressor can serve as the working body for
pneumatic actuator. The working pressure of the actuator
is 2.5 ... 8 bar (Max. pressure 413 bar). This principle
allows reducing expenses for maintenance of the complex
due to the automated regeneration of gas for the actuator
control.
OPERATING ENVIRONMENT SYSTEM:
The system conform to the type of climatic performance
of UHL and location category 1 by GOST 15150
The system is intended for installation in hazardous
production facilities in accordance with the requirements of
norms and rules of industrial safety, and also according to
requirements of Chapter 7.3 of PUE (seventh edition), and
other normative-technical documents regulating the use of
equipment in potentially explosive areas
The complex meets the requirements of the normative
document "Gas Distribution systems. Standard technical
solutions for automation of technological equipment" P
Gazprom 2-1.17-586-2011
The capacity of the compressor
The receiver volume
Working pressure system
200 W
20..80 liters
4..6
www.rosteleservice.com [email protected] +7-800-250-01-04
INNOVATIONS OF YOUR BUSINESS
since 2004
AUTOMATED VALVING REMOTE CONTROL SYSTEM
АSDUZА-A-PPINNOVATIONS OF YOUR BUSINESS
since 2004
AUTOMATED VALVING REMOTE CONTROL SYSTEM
АSDUZА-A-PP
Emergency or planned opening / closing of isolation
valves on the facility upon command by operator or in
case of emergency readings of the system sensors
Collection, analysis, storage and transfer of process
parameters of the facility to the control room via wireless
communication channels
Facility perimeter guarding and control for opening
the cabinets with equipment, access control – the system
«friend/foe», instant notification of ADS about the
unauthorized access
SYSTEM FUNCTION:
APPLICATION SYSTEM:
Block valve stations of gas distribution and gas
transmission networks;
Block valve stations for oil transportation, storage
and reforming;
Ball valves up to and /or after gas distributing
plants;
Locking devices on the unguarded facilities that
are hard to access;
Block valve stations before dead-ended and
loopback gas distribution units;
Gas-fired heat generations and boiler rooms.
TECHNICAL SPECIFICATIONS:
General
Overall dimensions
Operating temperature range
Ingress protection rating
880х800х400mm (foundation - 720 mm)
100 kgWeight
-40°С.. +85°С
IР67
Solar-battery powerto be chosen depending on operating conditions: 65 W/ 150 W/ 250 W
Independent power supply, battery 24V, 27 А*h
Wireless data transmission and control channels
Redundant channel
Main channelGSM 900/1800 GPRS/CSD/SMS +redundant channel GSM (integrated)
«Iridium»/«Gonets» satellite channel
3. Ambient temperature
4. Gas/liquid temperature on Block valve station
1. Excessive gas/liquid pressure to Block valve station
2. Excessive gas/liquid pressure after Block valve station
5. Gas contamination (methane, carbon monoxide) on Block valve station
6. Isolation valve position (open/closed)
7. Continuity signal of actuator's control circuits
8. Location of doors in process room and cabinet
9. Guard condition of the Block valve station perimeter
10. Facility service signal
11. The status of self-contained power supply system (battery charge, solar battery performance control)
12. Signal intensity on main and redundant communication channel
Process parameters of the facility
Control system characteristics of driver
Driver's supply voltage
Max. starting current
Q-ty of connectable drivers with direct control
Q-ty of cycles for opening/closing with complete charge of battery
24V
2
Up to 120 cycles
Up to 16 А
SatelliteGonets
Ground-based radar Iridium
Pipeline
Pneumatic drive
with shutter
ASDUZA
Drive control system
AKB
GSM Iridium
Valv
e p
ositio
n
Control
Batt
ery
serv
ice life
Charg
e
Internet
E-m
ail
Internet
Redunda
nt
chan
nel
Main channel
ТСРE-m
ail
CCR
ARM
Solar battery
Server telemetry
Data base
RS-485ТСР
Redundant
channel
Redundant
channel
Вase station
Switching unit
Satellitetransmitter
Management of electro-pneumo-
valve
The system of preparation
of air
www.rosteleservice.com [email protected] +7-800-250-01-04