assignment – electrical plan

4
Houston Community College DRAFTING & DESIGN DEPARTMENT INSTRUCTOR: Mr. A. Jones CLASS: DFTG-2328 (Architectural Drafting – Commercial) ASSIGNMENT – Electrical Plan 1 / 4 TITLE: Electrical Plan OBJECTIVES: Discover the client’s needs and goals for a new commercial building. The student will document the client needs in both written and graphic formats. INSTRUCTIONS: Complete an electrical plan for your commercial building project. DEVELOPMENT REQUIREMENTS FOR ELECTRICAL PLAN Switch locations labeled with proper placement and identification, such as three-way, four-way, or dimmer. Inside and outside light fixture locations Switch legs drawn with dashed lines Duplex convenience outlets located based on code requirements (GFCI) outlets Exterior duplex convenience outlets, specifying weatherproof and GFCI Outlets for refrigerator, microwave, garbage disposal with switch, dishwasher, trash compactor, clothes washer Utility and appliance outlets: furnace, clothes dryer, range, ovens, and water heater shown and labeled. 200-V outlets for electric appliances as needed, or gas and 110-V outlets. Circuit panel location Electrical room/closet Lighting Schedule Legend Electrical notes (if necessary)

Upload: others

Post on 19-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ASSIGNMENT – Electrical Plan

Houston Community College DRAFTING & DESIGN DEPARTMENT

INSTRUCTOR: Mr. A. Jones CLASS: DFTG-2328 (Architectural Drafting – Commercial)

ASSIGNMENT – Electrical Plan

1 / 4

TITLE: Electrical Plan

OBJECTIVES: Discover the client’s needs and goals for a new commercial building. The student will document the client needs in both written and graphic formats.

INSTRUCTIONS: Complete an electrical plan for your commercial building project.

DEVELOPMENT REQUIREMENTS FOR ELECTRICAL PLAN

Switch locations labeled with proper placement and identification, such as three-way, four-way, or

dimmer. Inside and outside light fixture locations Switch legs drawn with dashed lines Duplex convenience outlets located based on code requirements (GFCI) outlets Exterior duplex convenience outlets, specifying weatherproof and GFCI Outlets for refrigerator, microwave, garbage disposal with switch, dishwasher, trash compactor, clothes washer Utility and appliance outlets: furnace, clothes dryer, range, ovens, and water heater shown and labeled. 200-V outlets for electric appliances as needed, or gas and 110-V outlets. Circuit panel location Electrical room/closet Lighting Schedule Legend Electrical notes (if necessary)

Page 2: ASSIGNMENT – Electrical Plan

Houston Community College DRAFTING & DESIGN DEPARTMENT

INSTRUCTOR: Mr. A. Jones CLASS: DFTG-2328 (Architectural Drafting – Commercial)

ASSIGNMENT – Electrical Plan

2 / 4

Electrical Symbols

Page 3: ASSIGNMENT – Electrical Plan

Houston Community College DRAFTING & DESIGN DEPARTMENT

INSTRUCTOR: Mr. A. Jones CLASS: DFTG-2328 (Architectural Drafting – Commercial)

ASSIGNMENT – Electrical Plan

3 / 4

Lighting Schedule

Page 4: ASSIGNMENT – Electrical Plan

Houston Community College DRAFTING & DESIGN DEPARTMENT

INSTRUCTOR: Mr. A. Jones CLASS: DFTG-2328 (Architectural Drafting – Commercial)

ASSIGNMENT – Electrical Plan

4 / 4