assemblies ester based mud resistant cable general...

36

Upload: lamdung

Post on 15-Jun-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based
Page 2: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33

Ester Based Mud Resistant Cable . . . . . . . . . 30-31

General Information• Ampacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Bend Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Hawke Gland Types . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Gexol Cable Stranding Profile . . . . . . . . . . . . . . . . . . 2

Instrumentation Cable. . . . . . . . . . . . . . . . . . . . 15-18• Individually Shielded Pairs. . . . . . . . . . . . . . . . 15 - 16• Individually Shielded Triads . . . . . . . . . . . . . . . 17 - 18

Multi-Conductor Control Cable . . . . . . . . . . . . 13-14

Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12• Single Conductor . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4• Two Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6• Three Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 8• Four Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10• Five Conductor. . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12

Type MMV Medium Voltage Power Cable . . 21-29

Type VFD Power Cable• Standard Gexol Insulated VFD Cable . . . . . . . . 19-20• MMV VFD Cable. . . . . . . . . . . . . . . . . . . . . . . . . 27-28

Assembly Solutions . . . . . . . . . . . . . . . . . . . . . . . . . 32

®

AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listedis approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.

n Fastest Lead Times• Standard 6 - 8 weeks• Emergency 2 - 4 weeks

n Best On-Time Delivery Rate*

n Highest Ampacity Ratings• DNV: 95°C• ABS: 100°C• Lloyd’s: 95°C

n Extremely Flexible

*Visit www.AmerCable.com for our most current on time delivery rate

Flame RetardantCertified to IEC 92-3 (332-3A)

and IEEE 1580

Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)

Oil ResistantDrilling Mud Resistant

Gexol® is a registered trademark of AmerCable Incorporated. Registered in the U.S. Patent and Trademark Office. © 2010 AmerCable Incorporated

Page 3: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

1

Diameter Conversion ➡ (inches to millimeters): Multiply by 25.4

Bend RadiusUnarmored Armored Armored & Sheathed

IEEE 45 6X Diameter 8X Diameter 8X Diameter

IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter

Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter

>1" (25mm)6X Diameter

Gexol® Insulated Oil & Gas Cables are the industry’s standard for premiumpower, control and instrumentationperformance. Gexol cables prove their value daily in the punishing operatingenvironments of offshore drilling andpetroleum facilities around the world.

Offshore applications challenge cableconstruction with relentless heat,vibration, salt corrosion, drilling mud and mechanical stress. And reliability is a huge issue – because it’s a long,long way to the nearest cable warehouse. You can depend on Gexol Insulated Oil & Gas cables for safe, reliable performance in theharshest operating conditions.

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Hawke Gland Types

110°C (Free Air) Ratings Based on IEEE Std. 835-1994 for isolated cables in freeair with full sun, 2 ft/s air movement, and a 45°C ambient.

110°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.

100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.

95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU rules and a 45°C ambient.

• Ampacities for four conductor cables are based on one conductor not acting as a normal current-carrying conductor (e.g., grounded neutral or grounding conductor).

• For free air ratings, the IEEE Std. 45 numbers can be divided by 0.85

Ampacity Ratings

®

Oil & Gas Cables

Page 4: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor

AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)

18

16

14

12

10

8

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

19

19

19

19

37

37

61

133

133

209

266

342

418

532

646

777

925

1110

1332

1591

1924

2745

0.0100

0.0117

0.0147

0.0185

0.0167

0.0201

0.0201

0.0177

0.0223

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

2

3

4

6

10

16

26

41

66

83

106

133

168

212

262

313

373

444

535

646

777

1111

0.96

1.32

2.08

3.29

5.23

7.57

12.49

21.11

33.51

42.79

54.45

70.01

85.57

108.91

132.25

159.06

189.36

227.23

272.68

325.70

393.87

561.94

0.049

0.059

0.074

0.093

0.113

0.136

0.175

0.258

0.324

0.361

0.407

0.461

0.510

0.575

0.654

0.720

0.785

0.860

0.941

1.029

1.132

1.354

Gexol Insulated Power, Control andInstrumentation Cable

Stranding Profile

Gexol Insulated Power, Control andInstrumentation Cable

Stranding ProfileOil & Gas Cables

2

Flame RetardantCertified to IEC 92-3 (332-3A)

and IEEE 1580

Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)

Oil ResistantDrilling Mud Resistant

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 5: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

3

37-102

Single Conductor Power CableGexol® InsulatedExtremely Flexible • 600V or 2kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� NVE 95/1696, FAL� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS) 91/60333 (E6)� American Bureau of Shipping (ABS) 99-BT5905-X� UL Listed as Marine Shipboard Cable (E111461) � United States Coast Guard November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.

Features� High strand count conductors make this product much

more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higher insulationresistance reduces electrical losses.

� Gexol’s excellent resistance to moisture produces stableelectrical properties throughout the life of the cable.

� In a fire condition, Gexol’s nonchlorinated flame retardantsystem produces less toxic and less corrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV 95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.� Suitable for use in Class I, Division 1 and Zone 1

environments (armored and sheathed).� Optional braid armor of bronze or tinned copper.

Insulation/JacketGEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 2000V/IEC 1000V.

Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245. Bronze standard. Tinned copper available by request.

ConductorSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

®

Oil & Gas Cables

Size Unarmored Inductive Voltage Drop DC Resistance AC Resistance at AmpacityAWG/ Part No. Diameter Weight Reactance at 110°C at 25°C 110°C, 60 Hz Free Airkcmil 37-102 (inches) (lbs/MFt.) (Ohms/k ft.) (Volts/Amp/kft.) (Volts/Amp/kft.) (Ohms/k ft.) 110°C 110°C 100°C 95°C18 -151 0.143 16 0.046 13.560 7.210 9.763 30 17 16 2016 -153 0.153 18 0.044 8.516 4.520 6.121 35 25 23 2314 -154 0.168 25 0.041 5.383 2.850 3.859 41 40 37 3212 -156 0.187 32 0.038 3.394 1.790 2.424 64 48 45 3810 -158 0.207 51 0.036 2.155 1.130 1.530 85 62 58 518 -159 0.255 71 0.036 1.338 0.694 0.940 112 77 72 686 -160 0.295 108 0.034 0.852 0.436 0.590 148 103 96 914 -162 0.377 173 0.030 0.583 0.286 0.399 196 137 128 1212 -164 0.443 242 0.029 0.368 0.175 0.244 259 181 169 1621 -165 0.484 335 0.029 0.301 0.140 0.195 298 208 194 187

1/0 -166 0.548 420 0.029 0.246 0.111 0.156 344 243 227 2172/0 -167 0.615 494 0.028 0.202 0.089 0.125 396 281 262 2503/0 -168 0.663 734 0.028 0.167 0.070 0.100 457 321 300 289

600VUnarmored

(2kV on next page)

Page 6: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

4

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 8

00-5

06-9

473

• 71

3-89

6-58

00 •

Fax

: 713

-849

-900

910

633

Wes

t Litt

le Y

ork

• Bl

dg. #

1 •

Suite

#10

0 •

Hou

ston

, TX

7704

1 •

ww

w. a

mer

cabl

e.co

m

*Una

rmor

ed 3

/0 a

nd s

mal

ler

has

a ja

cket

per

UL1

309

& IE

EE15

80Ca

ble

diam

eter

s sh

own

as n

omin

al a

re s

ubje

ct to

a ±

5% m

anuf

actu

ring

tole

ranc

eOrdering Gexol Oil & Gas Cables

Exam

ple:

Sing

le c

ondu

ctor

pow

er c

able

• 2k

V 10

0%•

535

kcm

il•

bron

ze a

rmor

ed &

she

athe

d

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

37–1

02– 124

BS

See

page

2 fo

r St

rand

ing

Prof

ile

37-102

Sing

le Con

ductor Pow

er Cab

leGe

xol®Insulated

Extr

emel

y Fl

exib

le •

2kV

• R

ated

110

°C

2kV – Flexible Power Cable – Single Conductor

Armored and

Unarmored

Armored (B)

Sheath (BS)

Size

Unarmored

Diam

eter

Nominal

Nominal

Inductive

Voltage Drop

DC ResistanceAC Resistance at

Ampacity

AWG/

Part No.

Diam

eter

Weight

Under Armor

Weight

Diam

eter

Weight

Diam

eter

Weight

Reactance

at 110°C

at 25°C

110°C, 60 Hz

Free Air

kcmil

mm2

37-102

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(Ohm

s/1000 ft.)

(Volts/Amp/1000 ft.)(Ohm

s/1000 ft.)

(Ohm

s/1000 ft.)

110°C

110°C

100°C

95°C

181.

0-1

010.

232*

290.

143

160.

193

290.

324

380.

065

13.5

807.

210

9.76

330

1716

2016

1.3

-102

0.24

5*34

0.15

318

0.20

332

0.33

442

0.06

28.

535

4.52

06.

121

3525

2323

142.

1-1

050.

259*

420.

168

250.

218

450.

349

600.

057

5.40

12.

850

3.85

941

4037

3212

3.3

-106

0.28

1*53

0.18

732

0.23

758

0.36

880

0.05

33.

410

1.79

02.

424

6448

4538

105.

2-1

080.

302*

680.

207

510.

257

930.

388

127

0.05

02.

170

1.13

01.

530

8562

5851

87.

6-1

090.

354*

950.

255

710.

305

116

0.43

615

90.

048

1.35

10.

694

0.94

011

277

7268

612

.5-1

100.

384*

130

0.29

510

80.

345

155

0.47

620

40.

045

0.86

40.

436

0.59

014

810

396

914

21-1

120.

484*

210

0.37

717

30.

427

230

0.55

829

60.

039

0.59

30.

286

0.39

919

613

712

812

12

34-1

140.

576*

314

0.44

324

20.

493

303

0.62

436

50.

037

0.37

60.

175

0.24

425

918

116

916

21

43-1

150.

629*

393

0.48

433

50.

534

406

0.66

546

80.

036

0.30

70.

140

0.19

529

820

819

418

71/

054

-116

0.68

7*48

50.

548

420

0.59

849

40.

729

571

0.03

50.

253

0.11

10.

156

344

243

227

217

2/0

70-1

170.

737*

596

0.61

549

40.

665

579

0.79

666

20.

034

0.20

80.

089

0.12

539

628

126

225

03/

086

-118

0.78

8*70

90.

663

627

0.71

377

60.

886

900

0.03

40.

174

0.07

00.

100

457

321

300

289

4/0

109

-119

0.81

082

00.

810

820

0.86

088

91.

038

1036

0.03

30.

145

0.05

60.

080

528

376

351

335

262

132

-120

0.88

894

50.

888

945

0.93

811

471.

111

1295

0.03

40.

127

0.04

60.

067

599

436

407

382

313

159

-121

0.95

411

130.

954

1113

1.00

413

321.

177

1491

0.03

30.

112

0.03

80.

056

604

487

455

427

373

189

-122

1.01

814

191.

018

1419

1.06

815

761.

241

1741

0.03

20.

099

0.03

20.

047

674

553

516

476

444

227

-123

1.09

415

781.

094

1578

1.14

418

161.

317

1992

0.03

10.

089

0.02

70.

041

750

630

588

531

535

273

-124

1.21

219

761.

212

1976

1.26

222

461.

435

2425

0.03

10.

081

0.02

20.

035

839

709

630

597

646

326

-126

1.30

023

481.

300

2348

1.35

025

591.

523

2757

0.03

10.

073

0.01

90.

030

937

783

731

671

777

394

-127

1.39

527

951.

395

2795

1.44

530

131.

618

3205

0.03

00.

067

0.01

50.

026

1048

881

822

753

1111

562

-129

1.66

839

821.

668

3982

1.71

841

291.

954

4484

0.03

00.

056

0.01

10.

018

1303

1098

1025

937

®

Oil & Gas Cables

Page 7: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

5

37-102

Two Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosettingcompound meeting UL 1309/CSA 245 and IEEE 1580.

InsulationGEXOL® cross-linked flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.Color code:Black-White

ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

Armor (Optional)Basket weave wire armor perIEEE 1580 and UL 1309/CSA245. Bronze standard.Tinned copper available byrequest.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 8: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

6

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Cable

dia

mete

rs s

how

n a

s n

om

inal are

subje

ct

to a

±5%

manufa

ctu

ring t

ole

rance

Armored and

Unarmored

Armored

(B)

Sheath (B

S)Size

Nominal

Nominal

Nominal

AC Resistance

Indu

ctive

Volta

ge Drop

AWG/

Part No

.Diam

eter

Weigh

tDiam

eter

Weigh

t Diam

eter

Weigh

tDC

Resistance at

110°C, 60 Hz

Reactance

110°C

Ampacity

kcmil

mm2

37-102

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

25°C (O

hms/1000 ft.)

(Ohm

s/1000 ft.)

(Ohm

s /100

0 ft.)(Volts/Amp/10

00 ft.)

110°C

100°C

95°C

161.

3-5

010.

350

750.

400

141

0.54

020

24.

610

6.12

10.

039

8.51

120

1920

142.

1-5

070.

380

840.

430

165

0.56

123

02.

907

3.85

90.

036

5.37

933

3127

123.

3-5

150.

420

111

0.47

019

00.

601

263

1.82

62.

424

0.03

43.

390

4340

3210

5.2

-553

0.46

014

60.

510

230

0.64

130

71.

153

1.53

00.

032

2.15

153

4943

87.

6-2

090.

600

221

0.65

032

70.

781

416

0.70

80.

940

0.03

41.

336

6964

586

12.5

-210

0.68

030

80.

730

424

0.90

355

90.

445

0.59

00.

032

0.85

091

8577

421

-594

0.88

751

60.

937

664

1.11

083

50.

300

0.39

90.

029

0.58

211

811

010

31/

054

-216

1.24

311

281.

293

1334

1.46

615

620.

117

0.15

60.

028

0.24

521

319

918

44/

010

9-2

191.

593

2003

1.64

322

711.

878

2680

0.05

90.

080

0.02

60.

138

329

307

285

37-102

Two Co

nductor P

ower Cab

leGe

xol®Insulated

Extr

emel

y Fl

exib

le •

0.6

/1kV

• R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 8

00-5

06-9

473

• 71

3-89

6-58

00 •

Fax

: 713

-849

-900

910

633

Wes

t Litt

le Y

ork

• Bl

dg. #

1 •

Suite

#10

0 •

Hou

ston

, TX

7704

1 •

ww

w. a

mer

cabl

e.co

m

Flexible Pow

er Cable – Two Co

nductor

Ordering Gexol Oil & Gas Cables

Exam

ple:

2 co

nduc

tor

pow

er c

able

• 0.

6/1k

V•

#4 A

WG

• br

onze

arm

ored

& s

heat

hed

Amer

Cabl

e G

exol

O

il &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(fro

m c

hart

s)Ar

mor

Req

uire

men

tBS

– a

rmor

ed &

shea

thed

Blan

k –

no a

rmor

37–1

02– 594

BS

®

Oil & Gas Cables

See

page

2 fo

r St

rand

ing

Prof

ile

Page 9: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

7

37-102

Three Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

ConductorSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.

InsulationGEXOL® cross-linked flameretardant polyolefin,meeting the requirementsfor Type P of IEEE 1580and Type X110 of UL 1309/CSA 245. Color code:Black-White-Red

Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copperavailable by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

An uninsulated ground conductormay be incorporated on a make-to-order basis.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 10: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

8

37-102

Three Co

nductor P

ower Cab

leGe

xol®Insulated

Extr

emel

y Fl

exib

le •

0.6

/1kV

• R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 8

00-5

06-9

473

• 71

3-89

6-58

00 •

Fax

: 713

-849

-900

910

633

Wes

t Litt

le Y

ork

• Bl

dg. #

1 •

Suite

#10

0 •

Hou

ston

, TX

7704

1 •

ww

w. a

mer

cabl

e.co

m

Flexible Pow

er Cable – Three Conductor

Cable

dia

mete

rs s

how

n a

s n

om

inal are

subje

ct

to a

±5%

manufa

ctu

ring t

ole

rance

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Armored and

Unarmored

Armored (B

)Sh

eath (B

S)Size

Nominal

Nominal

Nominal

AC Resistance

Indu

ctive

Volta

ge Drop

Opt. Un

insulated

AWG/

Part No

.Diam

eter

Weigh

tDiam

eter

Weight

Diam

eter

Weight

DC Resistance at

110°C, 60 Hz

Reactance

110°C

Grou

nding Co

nd.

Ampa

city

kcmil

mm2

37-102

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

25°C (O

hms/1000 ft.)

(Ohm

s/10

00 ft.)

(Ohm

s /100

0 ft.)(Volts/Amp/10

00 ft.)

Size AWG

110°C

100°C

95°C

161.

3-5

020.

369

650.

419

127

0.51

918

14.

610

6.12

10.

039

8.51

1–

1716

1614

2.1

-508

0.40

110

20.

451

176

0.58

322

82.

907

3.85

90.

036

5.37

9–

2725

2212

3.3

-516

0.44

513

30.

495

212

0.62

627

61.

826

2.42

40.

034

3.39

0–

3331

2710

5.2

-308

0.48

818

90.

538

281

0.66

935

21.

153

1.53

00.

032

2.15

1–

4441

368

7.6

-309

0.63

727

40.

687

385

0.81

847

70.

708

0.94

00.

034

1.33

6–

5652

486

12.5

-310

0.72

339

00.

773

519

0.94

665

00.

445

0.59

00.

032

0.85

08

7570

644

21-3

120.

942

678

0.99

284

31.

165

1004

0.30

00.

399

0.02

90.

582

899

9285

234

-314

1.08

498

71.

134

1160

1.30

713

740.

184

0.24

40.

028

0.36

66

131

122

113

143

-315

1.20

612

341.

256

1458

1.43

116

750.

147

0.19

50.

028

0.29

96

153

143

131

1/0

54-3

161.

326

1448

1.37

617

811.

550

2015

0.11

70.

156

0.02

80.

245

617

616

415

22/

070

-317

1.42

219

451.

472

2082

1.64

524

240.

093

0.12

50.

027

0.20

06

201

188

175

3/0

86-3

181.

528

2379

1.57

827

201.

814

3106

0.07

40.

100

0.02

70.

166

423

421

820

24/

010

9-3

191.

765

2864

1.81

532

332.

050

3652

0.05

80.

080

0.02

60.

138

427

025

223

526

213

2-3

201.

980

3452

2.03

038

802.

266

4434

0.04

80.

067

0.02

60.

119

331

529

426

731

315

9-3

212.

131

4023

2.18

144

342.

418

4919

0.04

00.

056

0.02

60.

105

334

432

129

937

318

9-3

222.

231

4772

2.28

152

192.

517

5718

0.03

40.

047

0.02

50.

092

338

736

133

444

422

7-3

232.

394

5670

2.44

461

762.

680

6864

0.02

80.

041

0.02

50.

083

244

041

137

253

527

3-3

242.

637

6784

2.68

774

922.

986

8250

0.02

40.

035

0.02

60.

075

249

844

341

864

632

6-3

262.

958

7961

3.00

884

143.

301

9258

0.02

00.

030

0.02

60.

068

155

351

647

077

739

4-3

273.

168

9573

3.21

810

065

3.51

110

945

0.01

60.

026

0.02

60.

063

160

256

252

9

Ordering Gexol Oil & Gas Cables

Exam

ple:

3 co

nduc

tor

pow

er c

able

• 0.

6/1k

V•

bron

ze a

rmor

ed &

she

athe

d•

with

gro

und

Amer

Cabl

e G

exol

O

il &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(fro

m c

hart

s)Ar

mor

Req

uire

men

tBS

– a

rmor

ed &

shea

thed

Blan

k –

no a

rmor

Gro

und

Cond

ucto

rG

– w

ith g

roun

d Bl

ank

– no

gro

und

37–1

02– 320

BSG

®

Oil & Gas Cables

See

page

2 fo

r St

rand

ing

Prof

ile

Page 11: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

9

37-102

Four Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color code:Black-White-Red-Green

ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

Armor (Optional)Basket weave wire armor perIEEE 1580 and UL 1309/CSA245. Bronze standard. Tinnedcopper available by request.

An uninsulated ground conductormay be incorporated on a make-to-order basis.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 12: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

10

37-102

Four Con

ductor Pow

er Cab

leGe

xol®Insulated

Extr

emel

y Fl

exib

le •

0.6

/1kV

• R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 8

00-5

06-9

473

• 71

3-89

6-58

00 •

Fax

: 713

-849

-900

910

633

Wes

t Litt

le Y

ork

• Bl

dg. #

1 •

Suite

#10

0 •

Hou

ston

, TX

7704

1 •

ww

w. a

mer

cabl

e.co

m

Flexible Pow

er Cable – Four Co

nductor

Cable

dia

mete

rs s

how

n a

s n

om

inal are

subje

ct

to a

±5%

manufa

ctu

ring t

ole

rance

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Armored and

Unarmored

Armored (B

)Sh

eath (B

S)Size

Nominal

Nominal

Nominal

AC Resistance

Inductive

Volta

ge Drop

Opt. Un

insulated

AWG/

Part No

.Diam

eter

Weigh

tDiam

eter

Weight

Diam

eter

Weight

DC Resistance at

110°C, 60 Hz

Reactance

110°C

Grou

nding Co

nd.

Ampa

city

kcmil

mm2

37-102

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

25°C (O

hms/1000

ft.)

(Ohm

s/1000

ft.)

(Ohm

s /100

0 ft.)(Volts/Amp/10

00 ft.)

Size AWG

110°C

100°C

95°C

161.

3-5

290.

402

990.

452

154

0.58

322

14.

610

6.12

10.

042

8.51

4–

1716

1614

2.1

-509

0.43

812

60.

488

213

0.61

926

22.

907

3.85

90.

039

5.38

2–

2725

2212

3.3

-517

0.48

616

80.

536

256

0.66

832

31.

826

2.42

40.

037

3.39

3–

3331

2710

5.2

-408

0.55

324

30.

603

313

0.73

439

01.

153

1.53

00.

035

2.15

4–

4441

368

7.6

-409

0.69

835

50.

748

466

0.92

159

10.

708

0.94

00.

037

1.33

9–

5652

486

12.5

-410

0.79

453

30.

844

669

1.01

780

80.

445

0.59

00.

035

0.85

38

7570

644

21-4

121.

035

879

1.08

510

621.

258

1236

0.30

00.

399

0.03

20.

585

899

9285

234

-414

1.19

411

201.

244

1345

1.41

716

770.

184

0.24

40.

030

0.36

96

131

122

113

143

-415

1.33

216

021.

382

1909

1.55

521

440.

147

0.19

50.

031

0.30

26

153

143

131

1/0

54-4

161.

465

1907

1.51

521

801.

750

2434

0.11

70.

156

0.03

00.

248

617

616

415

22/

070

-417

1.57

325

351.

623

2665

1.85

930

500.

093

0.12

50.

030

0.20

36

201

188

175

3/0

86-4

181.

754

3206

1.80

435

782.

040

4003

0.07

40.

100

0.02

90.

168

423

421

820

24/

010

9-4

191.

964

3765

2.01

442

142.

249

4670

0.05

80.

080

0.02

90.

140

427

025

223

526

213

2-4

202.

205

4625

2.25

547

952.

490

5610

0.04

80.

067

0.02

90.

122

331

529

426

731

315

9-4

212.

374

5367

2.42

458

682.

659

6395

0.04

00.

056

0.02

80.

107

334

432

129

937

318

9-4

222.

495

6462

2.54

568

532.

838

7576

0.03

40.

047

0.02

80.

095

338

736

133

444

422

7-4

232.

653

7560

2.70

379

873.

002

8760

0.02

80.

041

0.02

80.

086

244

041

137

253

527

3-4

242.

989

9284

3.03

997

623.

338

1057

00.

024

0.03

50.

028

0.07

72

463

443

418

646

326

-426

3.27

710

571

3.32

710

946

3.62

011

840

0.02

00.

030

0.02

90.

071

155

351

647

0

Ordering Gexol Oil & Gas Cables

Exam

ple:

4 co

nduc

tor

pow

er c

able

• 0.

6/1k

V•

#6 A

WG

• br

onze

arm

ored

& s

heat

hed

• w

ith g

roun

d

Amer

Cabl

e G

exol

O

il &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(fro

m c

hart

s)Ar

mor

Req

uire

men

tBS

– a

rmor

ed &

shea

thed

Blan

k –

no a

rmor

Gro

und

Cond

ucto

r G

– w

ith g

roun

d Bl

ank

– no

gro

und

37–1

02– 410

BSG

®

Oil & Gas Cables

See

page

2 fo

r St

rand

ing

Prof

ile

Page 13: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

11

37-102

Five Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade, flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color code:Black-White-Red-Green-Orange

ConductorsSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

Armor (Optional)Basket weave wire armor per IEEE 1580 andUL 1309/CSA 245. Bronzestandard. Tinned copper available by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 14: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

12

Armored and

Unarmored

Armored

(B)

Sheath (B

S)Size

Nominal

Nominal

Nominal

AC Resistance

Indu

ctive

Volta

ge Drop

AWG/

Part No

.Diam

eter

Weigh

tDiam

eter

Weight

Diam

eter

Weight

DC Resistance at

110°C, 60 Hz

Reactance

110°C

Ampa

city

kcmil

mm2

37-102

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

(inches)

(lbs/MFt.)

25°C (O

hms/1000 ft.)

(Ohm

s/10

00 ft.)

(Ohm

s /1000 ft.)(Volts/Amp/1000

ft.)

110°C

100°C

95°C

181.

0-5

580.

418

950.

468

165

0.59

921

47.

350

9.76

30.

044

13.5

5811

1011

161.

3-5

590.

437

110

0.48

718

90.

619

264

4.61

06.

121

0.04

28.

514

1413

1314

2.1

-510

0.47

914

90.

529

234

0.66

030

12.

907

3.85

90.

039

5.38

221

2018

123.

3-5

600.

550

196

0.60

026

60.

744

334

1.82

62.

424

0.03

73.

393

2725

2210

5.2

-561

0.60

429

60.

654

406

0.78

549

41.

153

1.53

00.

035

2.15

435

3329

87.

6-5

620.

765

453

0.81

556

90.

988

704

0.70

80.

940

0.03

71.

339

4542

386

12.5

-563

0.91

465

30.

964

813

1.13

797

30.

445

0.59

00.

035

0.85

360

5651

421

-565

1.13

710

731.

187

1292

1.36

014

810.

300

0.39

90.

032

0.58

579

7468

234

-566

1.31

513

611.

365

1637

1.53

818

560.

184

0.24

40.

030

0.36

910

598

901

43-5

671.

470

2130

1.52

021

921.

756

2482

0.14

70.

195

0.03

10.

302

122

114

105

1/0

54-5

681.

618

2550

1.66

827

461.

903

3108

0.11

70.

156

0.03

00.

248

140

131

122

2/0

70-5

691.

802

2954

1.85

233

012.

088

3734

0.09

30.

125

0.03

00.

203

161

150

140

4/0

109

-746

2.16

736

152.

217

3955

2.45

345

920.

058

0.08

00.

029

0.14

021

620

218

8

37-102

Five Con

ductor Pow

er Cab

leGe

xol®Insulated

Extr

emel

y Fl

exib

le •

0.6

/1kV

• R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 8

00-5

06-9

473

• 71

3-89

6-58

00 •

Fax

: 713

-849

-900

910

633

Wes

t Litt

le Y

ork

• Bl

dg. #

1 •

Suite

#10

0 •

Hou

ston

, TX

7704

1 •

ww

w. a

mer

cabl

e.co

m

Flexible Pow

er Cable – Five Co

nductor

Cable

dia

mete

rs s

how

n a

s n

om

inal are

subje

ct

to a

±5%

manufa

ctu

ring t

ole

rance

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Ordering Gexol Oil & Gas Cables

Exam

ple:

5 co

nduc

tor

pow

er c

able

• 0.

6/1k

V•

#2 A

WG

• br

onze

arm

ored

& s

heat

hed

Amer

Cabl

e G

exol

O

il &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(fro

m c

hart

s)Ar

mor

Req

uire

men

tBS

– a

rmor

ed &

shea

thed

Blan

k –

no a

rmor

37–1

02– 566

BS

®

Oil & Gas Cables

See

page

2 fo

r St

rand

ing

Prof

ile

Page 15: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

13

37-102

Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

InsulationGEXOL® cross-linked, flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580. Color code:IEEE 1580 Table 22

ConductorsSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580. Color code:IEEE 1580 Table 22

Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copper available by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 16: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-102

Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900914

GEXOL® is a registered trademark of AmerCable Incorporated

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter Weight Ampacity

AWG Conductors 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.) 110°C 100°C 95°C16 4 -529 0.402 99 0.452 154 0.583 227 17 16 1616 5 -559 0.437 110 0.487 189 0.619 264 14 13 1316 7 -505 0.475 155 0.525 255 0.656 330 12 11 1116 8 -503 0.531 164 0.581 265 0.712 340 12 11 1116 10 -504 0.631 206 0.681 366 0.812 445 9 8 1116 16 -546 0.719 299 0.769 465 0.942 602 9 8 1116 20 -687 0.794 360 0.844 560 1.017 724 9 8 1116 24 -525 0.923 462 0.973 718 1.146 809 8 7 1116 37 -526 1.048 658 1.098 819 1.271 989 6 6 816 44 -577 1.173 807 1.223 980 1.396 1175 6 6 816 60 -527 1.298 1053 1.348 1256 1.521 1496 6 6 816 91 -581 1.548 1595 1.598 1896 1.833 2181 6 6 814 4 -509 0.438 126 0.488 213 0.619 262 27 25 2214 5 -510 0.479 149 0.529 234 0.660 301 21 20 1814 6 -511 0.539 182 0.589 264 0.720 335 21 20 1814 7 -521 0.539 205 0.589 297 0.720 377 19 18 1514 10 -512 0.691 280 0.741 406 0.914 515 14 13 1514 12 -585 0.713 307 0.763 428 0.936 558 14 13 1514 14 -523 0.749 415 0.799 540 0.972 665 14 13 1514 20 -513 0.916 560 0.966 812 1.139 876 14 13 1514 24 -571 1.013 615 1.063 892 1.236 1132 12 11 1514 30 -573 1.071 780 1.121 965 1.294 1180 12 11 1314 37 -514 1.153 876 1.203 1135 1.376 1405 11 10 1314 44 -574 1.293 1087 1.343 1260 1.516 1477 10 9 1114 91 -582 1.775 2200 1.825 2465 2.060 2855 10 9 1112 4 -517 0.486 168 0.536 256 0.668 323 33 31 2712 5 -560 0.550 196 0.600 266 0.744 334 27 25 2212 6 -547 0.611 280 0.661 405 0.792 500 27 25 2212 10 -518 0.771 369 0.821 500 0.994 629 17 16 1912 20 -519 1.022 701 1.072 890 1.245 1055 17 16 1912 24 -572 1.133 861 1.183 1167 1.356 1468 15 14 1912 37 -520 1.293 1262 1.343 1467 1.516 1677 13 12 16

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Control Cable – Multi-Conductor

Ordering Gexol Oil & Gas CablesExample:

• Multi-Conductor control cable• 0.6/1kV• #12 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 519 BS

®

Oil & Gas Cables

See page 2 for Stranding Profile

Page 17: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

15

GEXOL® is a registered trademark of AmerCable Incorporated

37-102

Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

ConductorSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.

Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245.Bronze standard. Tinned copper availableby request.

InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

PairsEach pair is twisted with a bare tinned drain wire. Each pair is shielded withpolyester-backed aluminum foil tape to afford100% coverage. Pair to pairisolation plus overall shield is provided.Pair Color code:Black-White

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

Cable available with blue jacket or stripe to signify

intrinsically safe circuit.

37-102

Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 18: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

GEXOL® is a registered trademark of AmerCable Incorporated

37-102

Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900916

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Pairs 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -601 0.336 63 0.386 123 0.486 17618 2 -602 0.551 131 0.601 204 0.732 33518 3 -603 0.581 163 0.631 265 0.762 34318 4 -604 0.630 195 0.680 317 0.801 41018 5 -605 0.685 243 0.735 395 0.900 51118 7 -606 0.742 340 0.792 457 0.957 57518 8 -607 0.800 388 0.850 521 1.015 75218 10 -608 0.976 495 1.026 699 1.199 87418 12 -609 1.011 581 1.061 780 1.234 98218 16 -645 1.121 748 1.171 833 1.344 118218 18 -641 1.181 824 1.231 1050 1.404 130018 24 -646 1.382 1069 1.432 1151 1.605 172016 1 -610 0.356 77 0.406 120 0.507 20316 2 -611 0.565 160 0.615 249 0.751 37716 3 -612 0.617 200 0.667 311 0.785 41016 4 -613 0.671 239 0.721 389 0.886 56916 5 -614 0.730 297 0.780 483 0.945 60916 7 -615 0.792 416 0.842 559 1.007 70316 8 -616 0.896 475 0.946 638 1.119 80316 10 -617 1.047 606 1.097 787 1.270 109816 12 -618 1.081 711 1.131 923 1.304 113816 16 -619 1.207 948 1.257 1231 1.422 151716 18 -626 1.265 1100 1.315 1260 1.488 157016 20 -688 1.327 1215 1.377 1476 1.552 189416 24 -699 1.482 1510 1.532 1625 1.767 206514 1 -620 0.386 97 0.436 151 0.537 19914 2 -621 0.621 202 0.671 315 0.802 48114 3 -622 0.658 251 0.708 391 0.881 51514 4 -623 0.721 301 0.771 469 0.944 63314 5 -624 0.791 374 0.841 608 1.013 78714 7 -625 0.905 524 0.955 704 1.128 88614 8 -630 0.979 498 1.029 803 1.202 101114 10 -627 1.148 747 1.198 1003 1.371 119614 12 -628 1.186 896 1.236 1203 1.409 1434

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Instrumentation Cable – Individually Shielded Pairs

Ordering Gexol Oil & Gas CablesExample:

• Instrumentation cable• 0.6/1kV• #14 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 620 BS

VALUES:

#18 PairsCapacitance (nF/1000 feet) = 28Inductance (mH/1000) = 0.22Resistance (Ohms/1000 feet) = 7.21 (@ 20°C)

#16 PairsCapacitance (nF/1000 feet) = 32Inductance (mH/1000) = 0.20Resistance (Ohms/1000 feet) = 4.52 (@ 20°C)

#14 PairsCapacitance (nF/1000 feet) = 37Inductance (mH/1000) = 0.19Resistance (Ohms/1000 feet) = 2.85 (@ 20°C)

See page 2 for StrandingProfile

®

Oil & Gas Cables

Page 19: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

17

37-102

Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

ConductorSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.

Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245.Bronze standard. Tinnedcopper available byrequest.

InsulationGEXOL® cross-linked, flame retardant polyolefin,meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosettingcompound meeting UL 1309/CSA 245 and IEEE 1580.

TriadsEach triad is twisted with a bare tinned drain wire.Each triad is shielded with polyester-backed aluminum foil tape to afford100% coverage. Triad to triad isolation plus overallshielding is provided.Triad Color code:Black-White-Red

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Cable available with blue jacket or stripe to signify

intrinsically safe circuit.

37-102

Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 20: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-102

Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900918

GEXOL® is a registered trademark of AmerCable Incorporated

#18 Triads

Capacitance – (nF/1000 feet) = 28

Inductance – (mH/1000) = 0.22

Resistance – (Ohms/1000 feet) = 7.21 (@ 20°C)

#16 TriadsCapacitance – (nF/1000 feet) = 32

Inductance – (mH/1000) = 0.20

Resistance – (Ohms/1000 feet) = 4.52 (@ 20°C)

VALUES:

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Triads 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -647 0.354 75 0.404 144 0.504 19918 2 -681 0.649 183 0.699 290 0.872 38018 3 -648 0.688 190 0.738 305 0.911 39318 4 -682 0.755 281 0.805 408 0.978 55118 5 -649 0.871 286 0.921 419 1.094 56118 7 -650 0.947 409 0.997 565 1.170 72418 8 -683 1.026 515 1.076 680 1.249 87018 12 -640 1.244 766 1.294 965 1.467 119516 1 -668 0.376 86 0.426 155 0.558 21316 3 -669 0.735 218 0.785 338 0.958 46616 4 -698 0.807 410 0.857 530 1.030 70016 6 -676 1.012 630 1.062 750 1.235 95516 7 -670 1.012 710 1.062 835 1.235 105016 8 -677 1.090 729 1.140 876 1.330 1103

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Instrumentation Cable – Individually Shielded Triads

Ordering Gexol Oil & Gas CablesExample:

• Instrumentation cable• 0.6/1kV • #18 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 682 BS

®

Oil & Gas Cables

See page 2 for Stranding Profile

Page 21: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-102VFD

Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C

www. amercable.com • e-mail: [email protected] 19

ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.

Featuresn Specially engineered cable design produces

a longer cable life in VFD applications.n Overall braid plus foil shield is engineered

with 100% coverage and a surface transferimpedance <50 milliohms at 10MHz to contain EMI.

n Symmetrical insulated ground conductorsreduce induced voltage imbalances and carrycommon mode noise back to the drive.

n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable.

n Gexol’s lower dielectric constant (standardXLPEs, EPRs and other Type P insulation materials have higher dielectric constants)reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system.

n 2kV insulation thickness is used to resist thepotential 2-3x reflected voltages experienced in 600V VFD applications.

n Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

n Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

n Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

n Flame retardant: IEC 332-3 Category A and IEEE 1202.

n Suitable for use in Class I, Division 1 andZone 1 environments (armored andsheathed).

n Optional braid armor of bronze, aluminum or tinned copper.

Insulation (2kV)Gexol® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color: Gray with printedphase I.D. (Black-White-Red)

Power Conductors (x3)Soft annealed flexible strandedtinned copper per IEEE 1580Table 11.

Ground Conductors (x3)Soft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.Gexol® insulation sized per UL 1277.Color: Green

JacketA black, arctic grade, flameretardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL1309/CSA 245 and IEEE 1580.

ShieldTinned copper basket weavewire armor per IEEE 1580 and UL 1309/CSA 245 plusaluminum/polyester tape providing 100% coverage.

Ratings & Approvalsn 110˚C Temperature Ratingn American Bureau of Shipping (ABS): 99-BT5905-Xn Transport Canada: 8700-20-2n Det Norske Veritas (DNV): E-6669, E-6388,

E-6390, E-6391n Lloyd’s Register of Shipping (LRS): 91/60333 (E6)n NVE: 95/1696, FALn UL Listed as Marine Shipboard Cable: (E111461)n Unarmored Cable is UL Listed as Type TC (E123629)n United States Coast Guard: November 2, 1987 / 9304

Other certifications pending

Gexol insulation has low capacitancefor superior performance in

VFD applications!

®

Oil & Gas Cables

Armor (Optional)Tinned copper basket weavewire armor per IEEE 1580

and UL 1309/CSA 245.

Sheath (Optional)A black, arctic grade, flame retardant, oil,

abrasion, chemical and sunlight resistant

thermosetting compound meeting UL 1309/CSA 245

and IEEE 1580.

Note: For armored versions the braid is placed betweenin inner jacket and outer sheath where it servesas both the EMI shield and armor.

Page 22: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-102VFD

Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900920

GEXOL® is a registered trademark of AmerCable Incorporated

*Cable diameters are subject to a +/- 5% manufacturing tolerance

andhas a

low capacitance for superior performancein VFD applications!

Gexolis

flexible

110°C RatingsBased on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.

100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.

95°C Ratings Based on 4-3-4/Table 10 of the 2001 ABS MODU rules and a 45°C ambient.

90°C Ratings Based on ICEA S-75-381 Table H-1 for a single isolated cable in air with a 40°C ambient. Thisampacity is typically used for mining and other portable applications.

75°C Ratings Based on Table B.310.1 of the 2005 NEC for cables in raceway and a 30°C ambient.

VFD Cable Ampacity Ratings

®

Oil & Gas Cables

See page 2 for Stranding Profile

Size Nominal Weight Nominal Weight Nominal WeightAWG/ Part No. Diameter Per Part No. Diameter Per Part No. Diameter Perkcmil 37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. Size (AWG) 110˚C 100˚C 95˚C 90˚C 75˚C

14 -508VFD 0.622 194 -508BVFD 0.672 281 -508BSVFD 0.772 349 18 27 25 22 - 18

12 -516VFD 0.671 224 -516BVFD 0.721 321 -516BSVFD 0.795 383 18 33 31 27 - 24

10 -308VFD 0.725 308 -308BVFD 0.775 412 -308BSVFD 0.918 518 14 44 41 36 - 33

8 -309VFD 0.780 441 -309BVFD 0.830 565 -309BSVFD 0.973 616 14 56 52 48 - 43

6 -310VFD 0.910 570 -310BVFD 0.960 708 -310BSVFD 1.098 832 12 75 70 64 93 58

4 -312VFD 1.072 886 -312BVFD 1.125 1061 -312BSVFD 1.262 1128 12 99 92 85 122 79

2 -314VFD 1.215 1421 -314BVFD 1.271 1618 -314BSVFD 1.393 1712 10 131 122 113 159 105

1 -315VFD 1.340 1517 -315BVFD 1.395 1743 -315BSVFD 1.509 1836 10 153 143 131 184 121

1/0 -316VFD 1.443 1803 -316BVFD 1.493 2027 -316BSVFD 1.615 2137 10 176 164 152 211 145

2/0 -317VFD 1.572 2153 -317BVFD 1.622 2399 -317BSVFD 1.792 2660 10 201 188 175 243 166

3/0 -318VFD 1.750 2827 -318BVFD 1.800 3073 -318BSVFD 1.901 3133 8 234 218 202 270 189

4/0 -319VFD 2.053 3463 -319BVFD 2.103 3785 -319BSVFD 2.102 3864 8 270 252 235 321 223

262 -320VFD 2.193 4175 -320BVFD 2.243 4522 -320BSVFD 2.320 4695 6 315 294 267 365 254

313 -321VFD 2.370 4727 -321BVFD 2.420 5104 -321BSVFD 2.421 5326 6 344 321 299 408 287

373 -322VFD 2.501 5415 -322BVFD 2.551 5809 -322BSVFD 2.555 6091 6 387 361 334 451 315

444 -323VFD 2.670 6707 -323BVFD 2.721 7141 -323BSVFD 2.703 7422 6 440 411 372 499 350

535 -324VFD 2.972 7483 -324BVFD 3.022 7966 -324BSVFD 3.016 8504 6 498 443 418 - 390

646 -326VFD 3.164 8916 -326BVFD 3.214 9428 -326BSVFD 3.270 10034 4 553 516 470 - 431

777 -327VFD 3.388 10395 -327BVFD 3.438 10940 -327BSVFD 3.489 11877 4 602 562 529 473

Green InsulatedGrounding

Conductor (x3)

Unarmored ArmoredArmored &

Sheathed (BS)

Ampacity

Termination KitsAmerCable Systems offers pre-sized and

pre-formed terminationkit packages specifically

for VFD cable constructions

Page 23: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-102VFD

Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C

37-105

Type MMV Medium Power CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

www. amercable.com • e-mail: [email protected]

ApplicationsAmerCable’s Type MMV marine mediumvoltage cables are for use aboard commercial ships, mobile offshoredrilling units (MODUs), and fixed orfloating offshore facilities.

Featuresn These cables utilize flexible

stranded conductors, braided shieldsand a braided armor (when armored)which make them very suitable forapplications involving repeated flexingand high vibration.

n These cables have a small minimumbending radius (6xOD for unarmoredcables and 8xOD for armored cables) for easy installation.

n Optional uninsulated groundingconductors sized per UL 1072.

n The increased flexibility of this cableallows for termination of one end and coiling on multiple module offshore platforms. Then coiling andterminating other end when modulesare mated at sea thereby reducinginstallation time.

n Passes IEC 332-3 Category A and IEEE 1202 flame tests.

Conductor ShieldA combination of semi-conducting tape andextruded thermosetting semi-conducting materialmeeting UL 1309, IEEE 1580 and UL1072.

Armor (optional)(Optional) 0.0126" bronze braid providing 88%minimum coverage meeting UL 1309 and IEEEStd. 45-1998.

JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistant thermosettingcompound meeting UL 1309, IEEE 1580 and UL 1072. Colored jackets for signifying differentvoltage levels are also available on special request(ie. yellow = 5kV, orange = 8kV and red = 15kV).

Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion,chemical, and sunlight resistant thermosettingcompound meeting UL 1309, IEEE 1580 and UL 1072. Colored jackets for signifying differentvoltage levels is also available on special request(ie. yellow = 5kV, orange = 8kv and red = 15kV).

Metallic Shield

Composite shieldconsisting of 0.0126" tinned copper braided with nylon providing 60% copper Shieldedcoverage meeting UL 1309, IEEE Std. 1580 and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need toremove the shield to findan underlying colored tape.

Insulation ShieldSemi-conducting tape, with overlap, for fast andeasy termination meeting UL 1309, IEEE 1580 and UL 1072.

ConductorsSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Insulation

Extruded thermosetting90°C Ethylene PropyleneRubber (EPR), meeting UL 1309 (Type E), IEEE 1580 (Type E) and UL 1072.

Grounding Conductor (optional)One uninsulated soft annealed flexible strandedtinned copper conductor per ASTM B 33 andsized according to Table 21.1 of UL 1072.

Ratings & Approvals� UL Listed as Marine Shipboard Cable (E111461)� American Bureau of Shipping (ABS)� Det Norske Veritas (DNV) Pending� Lloyd’s Register of Shipping (LRS) Pending� 90˚C Temperature Rating� Voltage Rating – 5kV to 15kV

(25kV available on request)

Termination KitsAmerCable recommendsRaychem’s HVT seriesterminations for single conductorconstructions and HVT-M seriesterminations for multi-conductorconstructions.

®

Oil & Gas Cables

21

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 24: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

8

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

7.6

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

394

562

-101

-102

-103

-104

-105

-106

-107

-108

-109

-110

-111

-112

-113

-114

-115

-116

-117

0.564

0.604

0.686

0.750

0.790

0.877

0.937

0.980

1.042

1.121

1.187

1.252

1.327

1.408

1.496

1.599

1.883

204

252

344

449

528

659

787

910

1086

1272

1467

1692

1968

2294

2672

3154

4414

1.282

0.822

0.566

0.361

0.296

0.245

0.202

0.278

0.141

0.122

0.108

0.095

0.086

0.077

0.070

0.065

0.054

0.054

0.050

0.044

0.041

0.040

0.039

0.038

0.037

0.035

0.034

0.033

0.032

0.032

0.031

0.030

0.030

0.029

0.751

0.836

0.918

0.981

1.064

1.108

1.168

1.212

1.274

1.353

1.419

1.484

1.559

1.706

1.793

1.881

2.169

401

502

622

748

894

1004

1160

1298

1496

1708

1926

2174

2476

2949

3361

3859

5255

0.061

0.058

0.051

0.047

0.047

0.045

0.043

0.042

0.040

0.038

0.037

0.036

0.035

0.035

0.034

0.033

0.033

1.288

0.830

0.573

0.367

0.303

0.250

0.207

0.173

0.146

0.127

0.112

0.099

0.090

0.082

0.075

0.069

0.057

80

107

141

186

214

247

285

328

381

435

486

544

606

682

767

865

1084

69

92

121

159

184

212

244

281

325

371

413

460

510

570

635

709

853

68

91

120

158

182

210

242

279

324

370

413

462

515

580

652

735

921

0.694

0.436

0.286

0.175

0.140

0.111

0.089

0.070

0.056

0.046

0.038

0.032

0.027

0.022

0.019

0.015

0.011

0.885

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

394

562

-118

-119

-120

-121

-122

-123

-124

-125

-126

-127

-128

-129

-130

-131

-132

-133

0.656

0.738

0.801

0.884

0.929

0.989

1.032

1.094

1.173

1.239

1.304

1.379

1.460

1.548

1.651

1.935

283

378

486

604

702

835

956

1135

1324

1522

1750

2029

2359

2741

3186

4498

0.824

0.567

0.362

0.298

0.246

0.203

0.169

0.142

0.123

0.109

0.096

0.087

0.078

0.071

0.066

0.055

0.052

0.046

0.043

0.042

0.041

0.039

0.038

0.036

0.035

0.034

0.033

0.033

0.032

0.031

0.030

0.030

0.888

0.970

1.033

1.108

1.160

1.220

1.264

1.326

1.405

1.471

1.536

1.603

1.746

1.833

1.949

2.233

549

673

806

942

1072

1226

1363

1563

1779

1999

2250

2538

3012

3428

3944

5388

0.059

0.052

0.048

0.047

0.046

0.044

0.043

0.041

0.039

0.038

0.037

0.036

0.036

0.035

0.034

0.033

0.831

0.574

0.368

0.304

0.251

0.208

0.174

0.147

0.128

0.113

0.100

0.091

0.082

0.075

0.070

0.058

107

141

186

214

247

285

328

381

435

486

544

606

682

767

865

1084

92

121

159

184

212

244

281

325

371

413

460

510

570

635

709

853

91

120

158

182

210

242

279

324

370

413

462

515

580

652

735

921

0.436

0.286

0.175

0.140

0.111

0.089

0.070

0.056

0.046

0.038

0.032

0.027

0.022

0.019

0.015

0.011

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

®

Oil & Gas Cables

22 Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-9009

See page 29 for MMV

Stranding Profile

Page 25: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

www. amercable.com • e-mail: [email protected] 23

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

394

562

-134

-135

-136

-137

-138

-139

-140

-141

-142

-143

-144

-145

-146

-147

-148

-149

0.710

0.792

0.898

0.938

0.983

1.043

1.086

1.148

1.227

1.293

1.358

1.433

1.460

1.602

1.767

1.989

317

417

565

648

751

884

1007

1189

1381

1584

1813

2095

2359

2814

3376

4587

0.826

0.569

0.365

0.300

0.247

0.204

0.171

0.143

0.124

0.110

0.097

0.088

0.078

0.072

0.067

0.055

0.054

0.047

0.045

0.044

0.042

0.040

0.039

0.038

0.036

0.035

0.034

0.033

0.032

0.032

0.032

0.031

0.942

1.016

1.129

1.170

1.214

1.274

1.318

1.380

1.459

1.524

1.582

1.719

1.758

1.888

2.065

2.275

603

725

916

1022

1140

1293

1432

1635

1854

2081

2318

2734

3034

3529

4181

5470

0.060

0.053

0.050

0.049

0.047

0.045

0.044

0.042

0.040

0.039

0.038

0.038

0.036

0.036

0.036

0.034

0.832

0.575

0.370

0.305

0.252

0.209

0.175

0.148

0.129

0.114

0.101

0.093

0.083

0.076

0.071

0.058

107

141

186

214

247

285

328

381

435

486

544

606

682

767

865

1084

92

121

159

184

212

244

281

325

371

413

460

510

570

635

709

853

91

120

158

182

210

242

279

324

370

413

462

515

580

652

735

921

0.436

0.286

0.175

0.140

0.111

0.089

0.070

0.056

0.046

0.038

0.032

0.027

0.022

0.019

0.015

0.011

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

34

43

54

70

86

109

132

159

189

227

273

326

394

562

-150

-151

-152

-153

-154

-155

-156

-157

-158

-159

-160

-161

-162

-163

1.050

1.088

1.133

1.191

1.236

1.298

1.397

1.463

1.528

1.603

1.742

1.830

1.965

2.187

692

778

883

1024

1154

1343

1568

1778

2015

2313

2762

3165

3729

4930

0.369

0.303

0.251

0.208

0.174

0.146

0.128

0.113

0.100

0.091

0.082

0.075

0.070

0.057

0.049

0.047

0.045

0.044

0.042

0.040

0.039

0.038

0.037

0.036

0.036

0.035

0.034

0.033

1.269

1.308

1.352

1.410

1.456

1.518

1.616

1.744

1.809

1.884

2.024

2.112

2.246

2.468

1088

1186

1301

1462

1608

1817

2077

2422

2685

3014

3520

3960

4578

5870

0.053

0.051

0.049

0.047

0.046

0.044

0.042

0.042

0.041

0.040

0.039

0.038

0.037

0.036

0.373

0.308

0.255

0.212

0.178

0.150

0.131

0.117

0.104

0.095

0.086

0.079

0.073

0.060

186

214

247

284

327

378

431

481

536

598

672

754

848

1061

164

189

217

250

288

332

377

418

464

514

574

638

709

857

158

182

210

241

278

321

366

409

456

508

571

641

721

902

0.175

0.140

0.111

0.089

0.070

0.056

0.046

0.038

0.032

0.027

0.022

0.019

0.015

0.011

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

Page 26: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

34

43

54

70

86

109

132

159

189

227

273

326

394

562

-164

-165

-166

-167

-168

-169

-170

-171

-172

-173

-174

-175

-176

-177

1.132

1.170

1.215

1.273

1.338

1.400

1.479

1.545

1.610

1.747

1.824

1.944

2.047

2.269

771

863

970

1112

1267

1461

1670

1884

2132

2541

2889

3350

3870

5083

0.370

0.305

0.252

0.209

0.176

0.148

0.129

0.114

0.101

0.093

0.084

0.077

0.071

0.058

0.050

0.049

0.047

0.045

0.044

0.042

0.040

0.039

0.038

0.038

0.037

0.036

0.035

0.034

1.352

1.390

1.434

1.492

1.558

1.620

1.761

1.827

1.892

2.029

2.106

2.226

2.329

2.551

1194

1299

1416

1578

1756

1971

2320

2561

2836

3301

3680

4191

4753

6057

0.055

0.053

0.051

0.049

0.047

0.046

0.044

0.043

0.042

0.041

0.040

0.039

0.038

0.036

0.375

0.309

0.256

0.213

0.179

0.151

0.133

0.118

0.105

0.096

0.087

0.080

0.074

0.061

186

214

247

284

327

378

431

481

536

598

672

754

848

1061

164

189

217

250

288

332

377

418

464

514

574

638

709

857

158

182

210

241

278

321

366

409

456

508

571

641

721

902

0.175

0.140

0.111

0.089

0.070

0.056

0.046

0.038

0.032

0.027

0.022

0.019

0.015

0.011

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

8

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

7.6

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

394

-301

-302

-303

-304

-305

-306

-307

-308

-309

-310

-311

-312

-313

-314

-315

-316

1.137

1.226

1.402

1.538

1.626

1.783

1.913

2.007

2.140

2.310

2.453

2.589

2.818

2.974

3.164

3.385

781

955

1307

1690

1974

2423

2884

3315

3937

4619

5319

6107

7280

8463

9814

11526

1218

1424

1824

2372

2692

3232

3749

4220

4899

5654

6549

7402

8684

9964

11407

13226

1.369

1.457

1.625

1.824

1.911

2.081

2.210

2.305

2.438

2.608

2.796

3.000

3.161

3.317

3.507

3.729

66

88

116

152

175

201

232

266

306

348

386

429

455

528

584

647

56

75

99

129

149

171

197

226

260

296

328

365

387

449

496

550

0.708

0.445

0.300

0.184

0.147

0.117

0.093

0.074

0.058

0.048

0.040

0.034

0.028

0.024

0.020

0.016

0.885

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.048

0.044

0.039

0.036

0.035

0.034

0.033

0.032

0.031

0.030

0.029

0.029

0.028

0.028

0.027

0.027

1.275

0.815

0.560

0.356

0.291

0.239

0.196

0.163

0.136

0.118

0.104

0.092

0.083

0.074

0.067

0.062

8

6

6

6

4

4

4

3

3

3

2

2

1

1

1

1/0

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900924

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

v2.08.1

Page 27: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

www. amercable.com • e-mail: [email protected] 25

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

-332

-333

-334

-335

-336

-337

-338

-339

-340

-341

-342

-343

-344

-345

1.454

1.630

1.829

1.916

2.012

2.141

2.236

2.369

2.539

2.680

2.885

3.036

3.210

3.400

1249

1639

2162

2467

2838

3327

3763

4417

5133

5870

6884

7959

9167

10554

1896

2359

2964

3306

3717

4259

4734

5443

6422

7227

8340

9491

10782

12261

1.740

1.916

2.114

2.202

2.297

2.427

2.521

2.654

2.888

3.031

3.235

3.380

3.552

3.742

88

116

152

175

201

232

266

306

348

386

429

455

528

584

75

99

129

149

171

197

226

260

296

328

365

387

449

496

0.445

0.300

0.184

0.147

0.117

0.093

0.074

0.058

0.048

0.040

0.034

0.028

0.024

0.020

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.048

0.043

0.040

0.038

0.037

0.036

0.035

0.033

0.032

0.032

0.031

0.030

0.030

0.029

0.820

0.564

0.359

0.294

0.242

0.199

0.166

0.139

0.121

0.106

0.094

0.085

0.076

0.069

6

6

6

4

4

4

3

3

3

2

2

1

1

1

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

12.5

21

34

43

54

70

86

109

132

159

189

227

273

326

394

-317

-318

-319

-320

-321

-322

-323

-324

-325

-326

-327

-328

-329

-330

-331

1.338

1.514

1.650

1.800

1.895

2.025

2.119

2.252

2.422

2.565

2.704

2.930

3.096

3.267

3.512

1094

1462

1970

2263

2617

3100

3531

4162

4864

5581

6392

7582

8806

10137

11959

1589

2134

2725

3054

3454

3989

4458

5140

5913

6884

7760

9059

10366

11780

13708

1.561

1.799

1.998

2.085

2.181

2.310

2.404

2.537

2.707

2.914

3.054

3.280

3.439

3.611

3.855

88

116

152

175

201

232

266

306

348

386

429

455

528

584

647

75

99

129

149

171

197

226

260

296

328

365

387

449

496

550

0.445

0.300

0.184

0.147

0.117

0.093

0.074

0.058

0.048

0.040

0.034

0.028

0.024

0.020

0.016

0.556

0.376

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.028

0.025

0.046

0.041

0.038

0.037

0.036

0.034

0.033

0.032

0.031

0.030

0.030

0.029

0.029

0.028

0.028

0.818

0.562

0.357

0.293

0.241

0.198

0.165

0.138

0.119

0.105

0.093

0.084

0.075

0.068

0.063

6

6

6

4

4

4

3

3

3

2

2

1

1

1

1/0

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

®

Oil & Gas Cables

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

See page 29 for MMV

Stranding Profile

Page 28: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

34

43

54

70

86

109

132

159

189

227

273

-346

-347

-348

-349

-350

-351

-352

-353

-354

-355

-356

2.157

2.239

2.335

2.461

2.559

2.691

2.749

2.881

3.021

3.183

3.357

2759

3073

3466

3991

4466

5150

5749

6483

7331

8380

9599

3697

4045

4477

5242

5764

6513

7348

8184

8856

9983

11285

2.443

2.524

2.620

2.810

2.910

3.041

3.152

3.287

3.365

3.527

3.701

156

178

205

234

269

309

352

389

432

456

528

133

151

174

199

229

263

299

331

367

388

449

0.184

0.147

0.117

0.093

0.074

0.058

0.048

0.040

0.034

0.028

0.024

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.042

0.040

0.039

0.037

0.036

0.035

0.034

0.033

0.032

0.031

0.031

0.361

0.296

0.244

0.201

0.168

0.141

0.122

0.107

0.095

0.086

0.077

6

4

4

4

3

3

3

2

2

1

1

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

34

43

54

70

86

109

132

159

189

227

273

-357

-358

-359

-360

-361

-362

-363

-364

-365

-366

-367

2.334

2.416

2.512

2.637

2.842

2.976

2.989

3.091

3.204

3.347

3.521

3125

3470

3874

4411

5206

5930

6412

6990

7897

8879

10144

4137

4515

5150

5748

6640

7430

7831

8529

9510

10560

11910

2.619

2.701

2.861

2.987

3.192

3.325

3.340

3.394

3.548

3.690

3.865

156

178

205

234

269

309

352

389

432

456

528

133

151

174

199

229

263

299

331

367

388

449

0.184

0.147

0.117

0.093

0.074

0.058

0.048

0.040

0.034

0.028

0.024

0.230

0.184

0.147

0.117

0.094

0.075

0.063

0.053

0.045

0.039

0.033

0.044

0.043

0.041

0.039

0.038

0.037

0.035

0.034

0.034

0.033

0.033

0.364

0.299

0.246

0.203

0.170

0.142

0.124

0.109

0.097

0.088

0.079

6

4

4

4

3

3

3

2

2

1

1

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900926

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

Page 29: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

www. amercable.com • e-mail: [email protected] 27

®

Oil & Gas Cables

v2.08.1

37-105VFD

Type MMV-VFDPower CableThree Conductor: 8kV – 15kV • 133% Insulation Level • Rated 90°C

ApplicationsA flexible, braid and foil shielded,power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications.

Featuresn Flexible stranded conductors and

braided shields. Suitable for applications involving repeated flexing and high vibration.

n Small minimum bending radius (8x OD) for easy installation.

n Insulation has a very low dielectricconstant. This allows for longeroutput cable distances andminimizes common mode current.

n Overall braid plus foil shield is engineered with 100% coverage anda surface transfer impedance <50milliohms at 10MHz to contain EMI.

n Symmetrical insulated ground conductors reduce induced voltageimbalances and carry common mode noise back to the drive.

n High strand count conductors andbraid shield design is much more flexible, easier to install and moreresistant to vibration than Type MC cable.

n Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).

n Flame retardant: IEC 332-3 Category A and IEEE 1202.

n Suitable for use in Class I, Division 1, and Zone 1 environments.

Conductors (3)Soft annealed flexible strandedtinned copper per IEEE 1580 Table 11.

Conductor ShieldA combination of semi-conducting tape and extruded thermosettingsemi-conducting materialmeeting UL 1309, IEEE 1580and UL1072.

Armor/EMI ShieldOverall tinned copper braid plus aluminum/polyestertape provides 100% coverage. This braid serves asboth an armor and EMI shield meeting both IEEE 1580and UL 1307/CSA 245.

JacketA black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580, and UL 1072. This jacket allows for isolation betweenthe insulation shields and overall shield. Shields canthen be terminated on oppostie ends to minimizecirculating currents.

Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580, and UL 1072. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = 15kV).

Insulation ShieldComposite shield consistingof 0.0126" tinned copperbraided with nylon providing 60% copperShielded coverage meetingUL 1309, IEEE Std. 1580,and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue,red) without the need toremove the shield to find anunderlying colored tape.

Insulation ShieldSemi-conducting layer meeting UL 1309, IEEE 1580 and UL 1072.Insulation

Extruded thermosetting90°C Ethylene PropyleneRubber (EPR), meetingUL 1309 (Type E), IEEE 1580 (Type E)and UL 1072.

Symmetrical InsulatedGrounding Conductors (3)Soft annealed flexible stranded tinned copper conductor per IEEE 1580 Table 11. Gexol Insulation sized per Table 23.2 of UL1072. Color: Green

Ratings & Approvalsn UL Listed as Marine Shipboard

Cable (E111461)n American Bureau of Shipping (ABS)n Det Norske Veritas (DNV) Pendingn Lloyd’s Register of Shipping (LRS)

Pendingn 90˚C Temperature Ratingn Voltage Rating – 8kV to 15kV

(25kV available on request)

Termination Kits

AmerCablerecommends

Raychem HVT-MSeries

Low smoke halogen-free jacket available on request.

Page 30: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

Manufactured by AmerCable, Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328

®

Oil & Gas Cables

Single Inductive Voltage Green InsulatedSize Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop GroundingAWG/ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)

6421

1/02/03/04/0262313373444535

12.5213443547086

109132159189227273

-332TSVFD-333TSVFD-334TSVFD-335TSVFD-336TSVFD-337TSVFD-338TSVFD-339TSVFD-340TSVFD-341TSVFD-342TSVFD-343TSVFD-344TSVFD

1634207426253022337338264411509359936867781088559905

1.6871.8682.0712.1612.2622.3812.4892.6313.8573.0303.1643.3193.492

88116152175201232266306348386429455528

7599

129149171197226260296328365387449

0.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.024

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.033

0.0480.0430.0400.0380.0370.0360.0350.0330.0320.0320.0310.0300.030

0.8200.5640.3590.2940.2420.1990.1660.1390.1210.1060.0940.0850.076

1010108886666444

Three Conductor Type MMV-VFD Marine Medium Voltage8kV • 133% Insulation Level

Ampacity

Ampacity

Single Inductive Voltage Green InsulatedSize Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop GroundingAWG/ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)

21

1/02/03/04/0262313373444

3443547086

109132159189227

-357TSVFD-358TSVFD-359TSVFD-360TSVFD-361TSVFD-362TSVFD-363TSVFD-364TSVFD-365TSVFD-366TSVFD

3231295940904615530661317074778787039912

2.4032.4682.5962.7142.8753.0283.2603.3633.5003.652

156178205234269309352389432456

133151174199229263299331367388

0.1840.1470.1170.0930.0740.0580.0480.0400.0340.028

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.039

0.0440.0430.041

0.0390.038

0.0370.0350.0340.0340.033

0.3640.2990.2460.2030.1700.1420.1240.1090.0970.080

10888666644

Three Conductor Type MMV-VFD Marine Medium Voltage15kV • 133% Insulation Level

Ordering Type MMV-VFD Medium Voltage CablesExample:

• 3 conductor MMV-VFD power cable• 15kV• #2 AWG

AmerCable Type MMV-VFD Prefix

Specific CableNumber (from charts)

37–105 – 357TSVFD

Stranding Profile:See Page 29

Page 31: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

www. amercable.com • e-mail: [email protected] 29

Ampacities are based on API RP 14F (June 1999)Table 4 or 5 for single conductor cables and Table3 for multi-conductor cables. The notes to thesetables are also applicable. Ampacities are alsobased on a 90°C conductor temperature and a45°C ambient temperature.

Inductive reactance and voltage drop values are based on a 90°C conductor temperature and 60 Hz operation. Values for single conductor cables are based on a symmetrical triangular configuration.

Please consult AmerCable on values for other configurations.

MMV Ampacities & Electrical Data

Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor

AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)

8

6

4

2

1

1/0

2/0

3/0

4/0

262

313

373

444

535

646

777

1111

37

61

133

133

209

266

342

418

532

646

777

925

1110

1332

1591

1924

2745

0.0201

0.0201

0.0177

0.0223

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

0.0201

16

26

41

66

83

106

133

168

212

262

313

373

444

535

646

777

1111

7.57

12.49

21.11

33.51

42.79

54.45

70.01

85.57

108.91

132.25

159.06

189.36

227.23

272.68

325.70

393.87

561.94

0.136

0.175

0.258

0.324

0.361

0.407

0.461

0.510

0.575

0.654

0.720

0.785

0.860

0.941

1.029

1.132

1.354

MMV Bend RadiusUnarmored Armored Armored & Sheathed

IEEE 45 6X Diameter 8X Diameter 8X Diameter

IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter

Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter

>1" (25mm)6X Diameter

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

MMV Stranding Profile

®

Oil & Gas Cables

Page 32: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.

Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.

30

Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable

A swollen orsplit cable jacket

due to drillingmud exposure

is a productivity

killer.

AmerCableoffers threelevels of mudresistance tomatch youroperatingconditions:

Standard, Advanced and

Ester Based Mud Resistant

Page 33: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

www. amercable.com • e-mail: [email protected] 31

1 All results representative of finished cables (6 3/C, 14 7/C and 18 7 PR). Test data on file at AmerCable

Aging Requirements

90°C Rated Jacket

121±1°C

Air Oven 240 Hours

Oil Exposure

Resistance

After Oil Immersion at

121±1°C 18 Hours

Jacket Type Type N Type N Mud Resistant Jacket

Tensile Strength, Min, PSI 1800 1800 Pass

300 300 Pass

20 20 Pass

Elongation at Rupture, Min, %

Set, Max, %

Tensile Strength,

Minimum900 psi 900 psi Pass

50%

Actual

50%

ActualPass

80 80 Pass

60 60 Pass

100 130 Pass

Elongation at Rupture, %

Tensile Strength, % Retention

of Unaged, Min

Elongation at Rupture, %

Retention of Unaged, Min

Mechanical Water

Absorptionmg / in2

Weatherometer TestNo

RequirementPass PassPer UL 1581

TearNo

Requirement35 Passlb/in Thickness, Min

FT4/IEEE 1202 Flame

Exposure (UL-1685)Pass Pass Pass–

IEC 332-3 Flame

Exposure

No

Requirement

No

RequirementPass–

Table ISpecifications UL-1309

Table 4IEEE 1580Table 5-7

AmerCable TestingProgram1

World Class Mud ResistantJacket

Physical

Requirements –

Unaged

When standard mud resistance isn’t enough, AmerCable has aWorld Class Mud Resistant cable jacket designed to deliveroutstanding performance in the harshest operating conditions.Designed specifically for exposure to high temperature ESTERBASED drilling muds, this cable meets all the performancerequirements of industry standards UL 1309 and IEEE 1580for Type N jackets. When tested for prolonged exposure to themost aggressive ester based drilling muds, it easily passes the mud resistance requirements of NEK 606.

AmerCable’s ester based mud resistant cables were also testedagainst the requirements of UL 1309 and IEEE 1580 and theresults are shown in Table I.1 This product easily passed allthe requirements. Table II shows the results of this cablewhen aged in Baroid Petrofree® (Ester Based) drilling mud perNEK 606. All aging requirements were met. Additional testingdone on these cables show the jacket to pass cold impact at -20°C and cold bend at -40°C.

Table II

MUD Resistant –

NEK 606

Note: Tested for

Changes in Each Listed

Requirement

70°C, 56 Days

Elongation at Break ±25% Baroid Petrofree® (Ester Based) Pass

Tensile Strength ±25% Baroid Petrofree® (Ester Based) Pass

Volume Swelling Max 20% Baroid Petrofree® (Ester Based) Pass

Weight Increase Max 15% Baroid Petrofree® (Ester Based)

Baroid Petrofree® (Ester Based)

Pass

Oxygen Index Min 25% Pass

Requirements Mud Type Results

Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable

®

Oil & Gas Cables

Page 34: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

32

Constructions:n 300V – 15kV AC

n AC & DC Power

n Composite Power & Control

n Instrumentation

n Thermocouple

n Fiber Optic

n Electro-Optic

Applications:n Service Loops

n Driller’s Console

n Mud Pump Controls

n 15kV Bridle Assembly

n Tender-to-PlatformBridle

n Ship-to-Shore Power

n Portable PowerGeneration

n Zone 1 (EX) Rated Cable Assemblies

Page 35: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

n 300V – 15kV AC n DC Power n Instrumentation n Composite Power & Control n Thermocouplen Fiber Optic n Electro-Optic

(800) 506-9473 • (713) 896-5800E-mail: [email protected]

www.amercablesystems.com

(877) 506-3010 • (713) 469-3981E-mail: [email protected]

www.amerrig.com

TM

Top DriveService Loops

Precision EngineeredCable Assemblies

n Highly reliable cable assemblies custom builtand tested to spec

n Fast Delivery

n Job-site application evaluation and consultation

Fiber OpticCable Solutions

CableAssemblySolutions

Standard & Custom Designs

Offshore and Land-based

Shortest Lead Times

Outstanding Customer Serivce

Shortest Lead Times

Outstanding Customer Serivce

33

Page 36: Assemblies Ester Based Mud Resistant Cable General …ncse.pro/wordpress/wp-content/themes/ETHERNA_WP/images/catalog… · Ester Based Mud Resistant Cable ... 95°C Ratings Based

1_11© 2010, AmerCable Incorporated

10633 West Little York • Building #1 • Suite #100 • Houston, TX 77041 800-506-9473 • 713-896-5800 • Fax: 713-849-9009 • e-mail: [email protected] • www.amercable.com

®

Low smokehalogen-freefire resistantor flameretardant Type P cables.

SHF1, SHF2and NEK 606IEC cables

Precisionengineered cableassembliesfor hazardousand industrialapplications.

Top DriveService Loops &Top DriveServices

VFDCABLES

Crush andImpactResistant Type P cableswithoutexternalarmoring.

Foil shielded,power cablesengineered for use in variablefrequency AC driveapplications.

Available in severalconstructions

AmerCable is an ISO 9001 certified cable manufacturerthat combines leading-edge manufacturing technology,

innovative thinking, and high quality service to deliver the finest oil & gas cable andengineered cable assemblies available.

AmerCable serves the world from our Oil & Gas Group headquarters in Houston, Texas. Ourprofessional field engineers and sales force work withyou to create innovative, cost-effective project solutions.

What can you expect from AmerCable?n Fastest Lead Times in the Industry

n On-Time Delivery

n Professional Sales, Support and Service

n Productivity Solutions

n Global Cable Management

AmerCable’s manufacturing facility in El Dorado, Arkansas.