assemblies ester based mud resistant cable general...
TRANSCRIPT
Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
Ester Based Mud Resistant Cable . . . . . . . . . 30-31
General Information• Ampacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Bend Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Hawke Gland Types . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Gexol Cable Stranding Profile . . . . . . . . . . . . . . . . . . 2
Instrumentation Cable. . . . . . . . . . . . . . . . . . . . 15-18• Individually Shielded Pairs. . . . . . . . . . . . . . . . 15 - 16• Individually Shielded Triads . . . . . . . . . . . . . . . 17 - 18
Multi-Conductor Control Cable . . . . . . . . . . . . 13-14
Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12• Single Conductor . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4• Two Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6• Three Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 8• Four Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10• Five Conductor. . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12
Type MMV Medium Voltage Power Cable . . 21-29
Type VFD Power Cable• Standard Gexol Insulated VFD Cable . . . . . . . . 19-20• MMV VFD Cable. . . . . . . . . . . . . . . . . . . . . . . . . 27-28
Assembly Solutions . . . . . . . . . . . . . . . . . . . . . . . . . 32
®
AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listedis approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.
n Fastest Lead Times• Standard 6 - 8 weeks• Emergency 2 - 4 weeks
n Best On-Time Delivery Rate*
n Highest Ampacity Ratings• DNV: 95°C• ABS: 100°C• Lloyd’s: 95°C
n Extremely Flexible
*Visit www.AmerCable.com for our most current on time delivery rate
Flame RetardantCertified to IEC 92-3 (332-3A)
and IEEE 1580
Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)
Oil ResistantDrilling Mud Resistant
Gexol® is a registered trademark of AmerCable Incorporated. Registered in the U.S. Patent and Trademark Office. © 2010 AmerCable Incorporated
1
Diameter Conversion ➡ (inches to millimeters): Multiply by 25.4
Bend RadiusUnarmored Armored Armored & Sheathed
IEEE 45 6X Diameter 8X Diameter 8X Diameter
IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter
Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter
>1" (25mm)6X Diameter
Gexol® Insulated Oil & Gas Cables are the industry’s standard for premiumpower, control and instrumentationperformance. Gexol cables prove their value daily in the punishing operatingenvironments of offshore drilling andpetroleum facilities around the world.
Offshore applications challenge cableconstruction with relentless heat,vibration, salt corrosion, drilling mud and mechanical stress. And reliability is a huge issue – because it’s a long,long way to the nearest cable warehouse. You can depend on Gexol Insulated Oil & Gas cables for safe, reliable performance in theharshest operating conditions.
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
Hawke Gland Types
110°C (Free Air) Ratings Based on IEEE Std. 835-1994 for isolated cables in freeair with full sun, 2 ft/s air movement, and a 45°C ambient.
110°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.
100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.
95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU rules and a 45°C ambient.
• Ampacities for four conductor cables are based on one conductor not acting as a normal current-carrying conductor (e.g., grounded neutral or grounding conductor).
• For free air ratings, the IEEE Std. 45 numbers can be divided by 0.85
Ampacity Ratings
®
Oil & Gas Cables
Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor
AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)
18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
19
19
19
19
37
37
61
133
133
209
266
342
418
532
646
777
925
1110
1332
1591
1924
2745
0.0100
0.0117
0.0147
0.0185
0.0167
0.0201
0.0201
0.0177
0.0223
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
2
3
4
6
10
16
26
41
66
83
106
133
168
212
262
313
373
444
535
646
777
1111
0.96
1.32
2.08
3.29
5.23
7.57
12.49
21.11
33.51
42.79
54.45
70.01
85.57
108.91
132.25
159.06
189.36
227.23
272.68
325.70
393.87
561.94
0.049
0.059
0.074
0.093
0.113
0.136
0.175
0.258
0.324
0.361
0.407
0.461
0.510
0.575
0.654
0.720
0.785
0.860
0.941
1.029
1.132
1.354
Gexol Insulated Power, Control andInstrumentation Cable
Stranding Profile
Gexol Insulated Power, Control andInstrumentation Cable
Stranding ProfileOil & Gas Cables
2
Flame RetardantCertified to IEC 92-3 (332-3A)
and IEEE 1580
Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)
Oil ResistantDrilling Mud Resistant
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
3
37-102
Single Conductor Power CableGexol® InsulatedExtremely Flexible • 600V or 2kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� NVE 95/1696, FAL� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS) 91/60333 (E6)� American Bureau of Shipping (ABS) 99-BT5905-X� UL Listed as Marine Shipboard Cable (E111461) � United States Coast Guard November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
ApplicationDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.
Features� High strand count conductors make this product much
more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higher insulationresistance reduces electrical losses.
� Gexol’s excellent resistance to moisture produces stableelectrical properties throughout the life of the cable.
� In a fire condition, Gexol’s nonchlorinated flame retardantsystem produces less toxic and less corrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV 95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.� Suitable for use in Class I, Division 1 and Zone 1
environments (armored and sheathed).� Optional braid armor of bronze or tinned copper.
Insulation/JacketGEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 2000V/IEC 1000V.
Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245. Bronze standard. Tinned copper available by request.
ConductorSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.
Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.
®
Oil & Gas Cables
Size Unarmored Inductive Voltage Drop DC Resistance AC Resistance at AmpacityAWG/ Part No. Diameter Weight Reactance at 110°C at 25°C 110°C, 60 Hz Free Airkcmil 37-102 (inches) (lbs/MFt.) (Ohms/k ft.) (Volts/Amp/kft.) (Volts/Amp/kft.) (Ohms/k ft.) 110°C 110°C 100°C 95°C18 -151 0.143 16 0.046 13.560 7.210 9.763 30 17 16 2016 -153 0.153 18 0.044 8.516 4.520 6.121 35 25 23 2314 -154 0.168 25 0.041 5.383 2.850 3.859 41 40 37 3212 -156 0.187 32 0.038 3.394 1.790 2.424 64 48 45 3810 -158 0.207 51 0.036 2.155 1.130 1.530 85 62 58 518 -159 0.255 71 0.036 1.338 0.694 0.940 112 77 72 686 -160 0.295 108 0.034 0.852 0.436 0.590 148 103 96 914 -162 0.377 173 0.030 0.583 0.286 0.399 196 137 128 1212 -164 0.443 242 0.029 0.368 0.175 0.244 259 181 169 1621 -165 0.484 335 0.029 0.301 0.140 0.195 298 208 194 187
1/0 -166 0.548 420 0.029 0.246 0.111 0.156 344 243 227 2172/0 -167 0.615 494 0.028 0.202 0.089 0.125 396 281 262 2503/0 -168 0.663 734 0.028 0.167 0.070 0.100 457 321 300 289
600VUnarmored
(2kV on next page)
4
GEXO
L®is
a re
gist
ered
trad
emar
k of
Am
erCa
ble
Inco
rpor
ated
Man
ufac
ture
d by
Am
erCa
ble
Inco
rpor
ated
• 8
00-5
06-9
473
• 71
3-89
6-58
00 •
Fax
: 713
-849
-900
910
633
Wes
t Litt
le Y
ork
• Bl
dg. #
1 •
Suite
#10
0 •
Hou
ston
, TX
7704
1 •
ww
w. a
mer
cabl
e.co
m
*Una
rmor
ed 3
/0 a
nd s
mal
ler
has
a ja
cket
per
UL1
309
& IE
EE15
80Ca
ble
diam
eter
s sh
own
as n
omin
al a
re s
ubje
ct to
a ±
5% m
anuf
actu
ring
tole
ranc
eOrdering Gexol Oil & Gas Cables
Exam
ple:
•
Sing
le c
ondu
ctor
pow
er c
able
• 2k
V 10
0%•
535
kcm
il•
bron
ze a
rmor
ed &
she
athe
d
Amer
Cabl
e Ge
xol
Oil &
Gas
Pre
fixSp
ecifi
c Ca
ble
Num
ber
(from
cha
rts)
Arm
or R
equi
rem
ent
BS –
arm
ored
&sh
eath
edBl
ank
– no
arm
or
37–1
02– 124
BS
See
page
2 fo
r St
rand
ing
Prof
ile
37-102
Sing
le Con
ductor Pow
er Cab
leGe
xol®Insulated
Extr
emel
y Fl
exib
le •
2kV
• R
ated
110
°C
2kV – Flexible Power Cable – Single Conductor
Armored and
Unarmored
Armored (B)
Sheath (BS)
Size
Unarmored
Diam
eter
Nominal
Nominal
Inductive
Voltage Drop
DC ResistanceAC Resistance at
Ampacity
AWG/
Part No.
Diam
eter
Weight
Under Armor
Weight
Diam
eter
Weight
Diam
eter
Weight
Reactance
at 110°C
at 25°C
110°C, 60 Hz
Free Air
kcmil
mm2
37-102
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(Ohm
s/1000 ft.)
(Volts/Amp/1000 ft.)(Ohm
s/1000 ft.)
(Ohm
s/1000 ft.)
110°C
110°C
100°C
95°C
181.
0-1
010.
232*
290.
143
160.
193
290.
324
380.
065
13.5
807.
210
9.76
330
1716
2016
1.3
-102
0.24
5*34
0.15
318
0.20
332
0.33
442
0.06
28.
535
4.52
06.
121
3525
2323
142.
1-1
050.
259*
420.
168
250.
218
450.
349
600.
057
5.40
12.
850
3.85
941
4037
3212
3.3
-106
0.28
1*53
0.18
732
0.23
758
0.36
880
0.05
33.
410
1.79
02.
424
6448
4538
105.
2-1
080.
302*
680.
207
510.
257
930.
388
127
0.05
02.
170
1.13
01.
530
8562
5851
87.
6-1
090.
354*
950.
255
710.
305
116
0.43
615
90.
048
1.35
10.
694
0.94
011
277
7268
612
.5-1
100.
384*
130
0.29
510
80.
345
155
0.47
620
40.
045
0.86
40.
436
0.59
014
810
396
914
21-1
120.
484*
210
0.37
717
30.
427
230
0.55
829
60.
039
0.59
30.
286
0.39
919
613
712
812
12
34-1
140.
576*
314
0.44
324
20.
493
303
0.62
436
50.
037
0.37
60.
175
0.24
425
918
116
916
21
43-1
150.
629*
393
0.48
433
50.
534
406
0.66
546
80.
036
0.30
70.
140
0.19
529
820
819
418
71/
054
-116
0.68
7*48
50.
548
420
0.59
849
40.
729
571
0.03
50.
253
0.11
10.
156
344
243
227
217
2/0
70-1
170.
737*
596
0.61
549
40.
665
579
0.79
666
20.
034
0.20
80.
089
0.12
539
628
126
225
03/
086
-118
0.78
8*70
90.
663
627
0.71
377
60.
886
900
0.03
40.
174
0.07
00.
100
457
321
300
289
4/0
109
-119
0.81
082
00.
810
820
0.86
088
91.
038
1036
0.03
30.
145
0.05
60.
080
528
376
351
335
262
132
-120
0.88
894
50.
888
945
0.93
811
471.
111
1295
0.03
40.
127
0.04
60.
067
599
436
407
382
313
159
-121
0.95
411
130.
954
1113
1.00
413
321.
177
1491
0.03
30.
112
0.03
80.
056
604
487
455
427
373
189
-122
1.01
814
191.
018
1419
1.06
815
761.
241
1741
0.03
20.
099
0.03
20.
047
674
553
516
476
444
227
-123
1.09
415
781.
094
1578
1.14
418
161.
317
1992
0.03
10.
089
0.02
70.
041
750
630
588
531
535
273
-124
1.21
219
761.
212
1976
1.26
222
461.
435
2425
0.03
10.
081
0.02
20.
035
839
709
630
597
646
326
-126
1.30
023
481.
300
2348
1.35
025
591.
523
2757
0.03
10.
073
0.01
90.
030
937
783
731
671
777
394
-127
1.39
527
951.
395
2795
1.44
530
131.
618
3205
0.03
00.
067
0.01
50.
026
1048
881
822
753
1111
562
-129
1.66
839
821.
668
3982
1.71
841
291.
954
4484
0.03
00.
056
0.01
10.
018
1303
1098
1025
937
®
Oil & Gas Cables
5
37-102
Two Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosettingcompound meeting UL 1309/CSA 245 and IEEE 1580.
InsulationGEXOL® cross-linked flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.Color code:Black-White
ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.
Armor (Optional)Basket weave wire armor perIEEE 1580 and UL 1309/CSA245. Bronze standard.Tinned copper available byrequest.
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronze or tinned copper.
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
6
GEXO
L®is
a re
gist
ered
trad
emar
k of
Am
erCa
ble
Inco
rpor
ated
Cable
dia
mete
rs s
how
n a
s n
om
inal are
subje
ct
to a
±5%
manufa
ctu
ring t
ole
rance
Armored and
Unarmored
Armored
(B)
Sheath (B
S)Size
Nominal
Nominal
Nominal
AC Resistance
Indu
ctive
Volta
ge Drop
AWG/
Part No
.Diam
eter
Weigh
tDiam
eter
Weigh
t Diam
eter
Weigh
tDC
Resistance at
110°C, 60 Hz
Reactance
110°C
Ampacity
kcmil
mm2
37-102
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
25°C (O
hms/1000 ft.)
(Ohm
s/1000 ft.)
(Ohm
s /100
0 ft.)(Volts/Amp/10
00 ft.)
110°C
100°C
95°C
161.
3-5
010.
350
750.
400
141
0.54
020
24.
610
6.12
10.
039
8.51
120
1920
142.
1-5
070.
380
840.
430
165
0.56
123
02.
907
3.85
90.
036
5.37
933
3127
123.
3-5
150.
420
111
0.47
019
00.
601
263
1.82
62.
424
0.03
43.
390
4340
3210
5.2
-553
0.46
014
60.
510
230
0.64
130
71.
153
1.53
00.
032
2.15
153
4943
87.
6-2
090.
600
221
0.65
032
70.
781
416
0.70
80.
940
0.03
41.
336
6964
586
12.5
-210
0.68
030
80.
730
424
0.90
355
90.
445
0.59
00.
032
0.85
091
8577
421
-594
0.88
751
60.
937
664
1.11
083
50.
300
0.39
90.
029
0.58
211
811
010
31/
054
-216
1.24
311
281.
293
1334
1.46
615
620.
117
0.15
60.
028
0.24
521
319
918
44/
010
9-2
191.
593
2003
1.64
322
711.
878
2680
0.05
90.
080
0.02
60.
138
329
307
285
37-102
Two Co
nductor P
ower Cab
leGe
xol®Insulated
Extr
emel
y Fl
exib
le •
0.6
/1kV
• R
ated
110
°C
Man
ufac
ture
d by
Am
erCa
ble
Inco
rpor
ated
• 8
00-5
06-9
473
• 71
3-89
6-58
00 •
Fax
: 713
-849
-900
910
633
Wes
t Litt
le Y
ork
• Bl
dg. #
1 •
Suite
#10
0 •
Hou
ston
, TX
7704
1 •
ww
w. a
mer
cabl
e.co
m
Flexible Pow
er Cable – Two Co
nductor
Ordering Gexol Oil & Gas Cables
Exam
ple:
•
2 co
nduc
tor
pow
er c
able
• 0.
6/1k
V•
#4 A
WG
• br
onze
arm
ored
& s
heat
hed
Amer
Cabl
e G
exol
O
il &
Gas
Pre
fixSp
ecifi
c Ca
ble
Num
ber
(fro
m c
hart
s)Ar
mor
Req
uire
men
tBS
– a
rmor
ed &
shea
thed
Blan
k –
no a
rmor
37–1
02– 594
BS
®
Oil & Gas Cables
See
page
2 fo
r St
rand
ing
Prof
ile
7
37-102
Three Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.
ConductorSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.
InsulationGEXOL® cross-linked flameretardant polyolefin,meeting the requirementsfor Type P of IEEE 1580and Type X110 of UL 1309/CSA 245. Color code:Black-White-Red
Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copperavailable by request.
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronzeor tinned copper.
An uninsulated ground conductormay be incorporated on a make-to-order basis.
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
8
37-102
Three Co
nductor P
ower Cab
leGe
xol®Insulated
Extr
emel
y Fl
exib
le •
0.6
/1kV
• R
ated
110
°C
Man
ufac
ture
d by
Am
erCa
ble
Inco
rpor
ated
• 8
00-5
06-9
473
• 71
3-89
6-58
00 •
Fax
: 713
-849
-900
910
633
Wes
t Litt
le Y
ork
• Bl
dg. #
1 •
Suite
#10
0 •
Hou
ston
, TX
7704
1 •
ww
w. a
mer
cabl
e.co
m
Flexible Pow
er Cable – Three Conductor
Cable
dia
mete
rs s
how
n a
s n
om
inal are
subje
ct
to a
±5%
manufa
ctu
ring t
ole
rance
GEXO
L®is
a re
gist
ered
trad
emar
k of
Am
erCa
ble
Inco
rpor
ated
Armored and
Unarmored
Armored (B
)Sh
eath (B
S)Size
Nominal
Nominal
Nominal
AC Resistance
Indu
ctive
Volta
ge Drop
Opt. Un
insulated
AWG/
Part No
.Diam
eter
Weigh
tDiam
eter
Weight
Diam
eter
Weight
DC Resistance at
110°C, 60 Hz
Reactance
110°C
Grou
nding Co
nd.
Ampa
city
kcmil
mm2
37-102
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
25°C (O
hms/1000 ft.)
(Ohm
s/10
00 ft.)
(Ohm
s /100
0 ft.)(Volts/Amp/10
00 ft.)
Size AWG
110°C
100°C
95°C
161.
3-5
020.
369
650.
419
127
0.51
918
14.
610
6.12
10.
039
8.51
1–
1716
1614
2.1
-508
0.40
110
20.
451
176
0.58
322
82.
907
3.85
90.
036
5.37
9–
2725
2212
3.3
-516
0.44
513
30.
495
212
0.62
627
61.
826
2.42
40.
034
3.39
0–
3331
2710
5.2
-308
0.48
818
90.
538
281
0.66
935
21.
153
1.53
00.
032
2.15
1–
4441
368
7.6
-309
0.63
727
40.
687
385
0.81
847
70.
708
0.94
00.
034
1.33
6–
5652
486
12.5
-310
0.72
339
00.
773
519
0.94
665
00.
445
0.59
00.
032
0.85
08
7570
644
21-3
120.
942
678
0.99
284
31.
165
1004
0.30
00.
399
0.02
90.
582
899
9285
234
-314
1.08
498
71.
134
1160
1.30
713
740.
184
0.24
40.
028
0.36
66
131
122
113
143
-315
1.20
612
341.
256
1458
1.43
116
750.
147
0.19
50.
028
0.29
96
153
143
131
1/0
54-3
161.
326
1448
1.37
617
811.
550
2015
0.11
70.
156
0.02
80.
245
617
616
415
22/
070
-317
1.42
219
451.
472
2082
1.64
524
240.
093
0.12
50.
027
0.20
06
201
188
175
3/0
86-3
181.
528
2379
1.57
827
201.
814
3106
0.07
40.
100
0.02
70.
166
423
421
820
24/
010
9-3
191.
765
2864
1.81
532
332.
050
3652
0.05
80.
080
0.02
60.
138
427
025
223
526
213
2-3
201.
980
3452
2.03
038
802.
266
4434
0.04
80.
067
0.02
60.
119
331
529
426
731
315
9-3
212.
131
4023
2.18
144
342.
418
4919
0.04
00.
056
0.02
60.
105
334
432
129
937
318
9-3
222.
231
4772
2.28
152
192.
517
5718
0.03
40.
047
0.02
50.
092
338
736
133
444
422
7-3
232.
394
5670
2.44
461
762.
680
6864
0.02
80.
041
0.02
50.
083
244
041
137
253
527
3-3
242.
637
6784
2.68
774
922.
986
8250
0.02
40.
035
0.02
60.
075
249
844
341
864
632
6-3
262.
958
7961
3.00
884
143.
301
9258
0.02
00.
030
0.02
60.
068
155
351
647
077
739
4-3
273.
168
9573
3.21
810
065
3.51
110
945
0.01
60.
026
0.02
60.
063
160
256
252
9
Ordering Gexol Oil & Gas Cables
Exam
ple:
•
3 co
nduc
tor
pow
er c
able
• 0.
6/1k
V•
bron
ze a
rmor
ed &
she
athe
d•
with
gro
und
Amer
Cabl
e G
exol
O
il &
Gas
Pre
fixSp
ecifi
c Ca
ble
Num
ber
(fro
m c
hart
s)Ar
mor
Req
uire
men
tBS
– a
rmor
ed &
shea
thed
Blan
k –
no a
rmor
Gro
und
Cond
ucto
rG
– w
ith g
roun
d Bl
ank
– no
gro
und
37–1
02– 320
BSG
®
Oil & Gas Cables
See
page
2 fo
r St
rand
ing
Prof
ile
9
37-102
Four Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.
InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color code:Black-White-Red-Green
ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronze or tinned copper.
Armor (Optional)Basket weave wire armor perIEEE 1580 and UL 1309/CSA245. Bronze standard. Tinnedcopper available by request.
An uninsulated ground conductormay be incorporated on a make-to-order basis.
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
10
37-102
Four Con
ductor Pow
er Cab
leGe
xol®Insulated
Extr
emel
y Fl
exib
le •
0.6
/1kV
• R
ated
110
°C
Man
ufac
ture
d by
Am
erCa
ble
Inco
rpor
ated
• 8
00-5
06-9
473
• 71
3-89
6-58
00 •
Fax
: 713
-849
-900
910
633
Wes
t Litt
le Y
ork
• Bl
dg. #
1 •
Suite
#10
0 •
Hou
ston
, TX
7704
1 •
ww
w. a
mer
cabl
e.co
m
Flexible Pow
er Cable – Four Co
nductor
Cable
dia
mete
rs s
how
n a
s n
om
inal are
subje
ct
to a
±5%
manufa
ctu
ring t
ole
rance
GEXO
L®is
a re
gist
ered
trad
emar
k of
Am
erCa
ble
Inco
rpor
ated
Armored and
Unarmored
Armored (B
)Sh
eath (B
S)Size
Nominal
Nominal
Nominal
AC Resistance
Inductive
Volta
ge Drop
Opt. Un
insulated
AWG/
Part No
.Diam
eter
Weigh
tDiam
eter
Weight
Diam
eter
Weight
DC Resistance at
110°C, 60 Hz
Reactance
110°C
Grou
nding Co
nd.
Ampa
city
kcmil
mm2
37-102
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
25°C (O
hms/1000
ft.)
(Ohm
s/1000
ft.)
(Ohm
s /100
0 ft.)(Volts/Amp/10
00 ft.)
Size AWG
110°C
100°C
95°C
161.
3-5
290.
402
990.
452
154
0.58
322
14.
610
6.12
10.
042
8.51
4–
1716
1614
2.1
-509
0.43
812
60.
488
213
0.61
926
22.
907
3.85
90.
039
5.38
2–
2725
2212
3.3
-517
0.48
616
80.
536
256
0.66
832
31.
826
2.42
40.
037
3.39
3–
3331
2710
5.2
-408
0.55
324
30.
603
313
0.73
439
01.
153
1.53
00.
035
2.15
4–
4441
368
7.6
-409
0.69
835
50.
748
466
0.92
159
10.
708
0.94
00.
037
1.33
9–
5652
486
12.5
-410
0.79
453
30.
844
669
1.01
780
80.
445
0.59
00.
035
0.85
38
7570
644
21-4
121.
035
879
1.08
510
621.
258
1236
0.30
00.
399
0.03
20.
585
899
9285
234
-414
1.19
411
201.
244
1345
1.41
716
770.
184
0.24
40.
030
0.36
96
131
122
113
143
-415
1.33
216
021.
382
1909
1.55
521
440.
147
0.19
50.
031
0.30
26
153
143
131
1/0
54-4
161.
465
1907
1.51
521
801.
750
2434
0.11
70.
156
0.03
00.
248
617
616
415
22/
070
-417
1.57
325
351.
623
2665
1.85
930
500.
093
0.12
50.
030
0.20
36
201
188
175
3/0
86-4
181.
754
3206
1.80
435
782.
040
4003
0.07
40.
100
0.02
90.
168
423
421
820
24/
010
9-4
191.
964
3765
2.01
442
142.
249
4670
0.05
80.
080
0.02
90.
140
427
025
223
526
213
2-4
202.
205
4625
2.25
547
952.
490
5610
0.04
80.
067
0.02
90.
122
331
529
426
731
315
9-4
212.
374
5367
2.42
458
682.
659
6395
0.04
00.
056
0.02
80.
107
334
432
129
937
318
9-4
222.
495
6462
2.54
568
532.
838
7576
0.03
40.
047
0.02
80.
095
338
736
133
444
422
7-4
232.
653
7560
2.70
379
873.
002
8760
0.02
80.
041
0.02
80.
086
244
041
137
253
527
3-4
242.
989
9284
3.03
997
623.
338
1057
00.
024
0.03
50.
028
0.07
72
463
443
418
646
326
-426
3.27
710
571
3.32
710
946
3.62
011
840
0.02
00.
030
0.02
90.
071
155
351
647
0
Ordering Gexol Oil & Gas Cables
Exam
ple:
•
4 co
nduc
tor
pow
er c
able
• 0.
6/1k
V•
#6 A
WG
• br
onze
arm
ored
& s
heat
hed
• w
ith g
roun
d
Amer
Cabl
e G
exol
O
il &
Gas
Pre
fixSp
ecifi
c Ca
ble
Num
ber
(fro
m c
hart
s)Ar
mor
Req
uire
men
tBS
– a
rmor
ed &
shea
thed
Blan
k –
no a
rmor
Gro
und
Cond
ucto
r G
– w
ith g
roun
d Bl
ank
– no
gro
und
37–1
02– 410
BSG
®
Oil & Gas Cables
See
page
2 fo
r St
rand
ing
Prof
ile
11
37-102
Five Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
JacketA black, arctic grade, flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.
InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color code:Black-White-Red-Green-Orange
ConductorsSoft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.
Armor (Optional)Basket weave wire armor per IEEE 1580 andUL 1309/CSA 245. Bronzestandard. Tinned copper available by request.
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronze or tinned copper.
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
12
Armored and
Unarmored
Armored
(B)
Sheath (B
S)Size
Nominal
Nominal
Nominal
AC Resistance
Indu
ctive
Volta
ge Drop
AWG/
Part No
.Diam
eter
Weigh
tDiam
eter
Weight
Diam
eter
Weight
DC Resistance at
110°C, 60 Hz
Reactance
110°C
Ampa
city
kcmil
mm2
37-102
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
(inches)
(lbs/MFt.)
25°C (O
hms/1000 ft.)
(Ohm
s/10
00 ft.)
(Ohm
s /1000 ft.)(Volts/Amp/1000
ft.)
110°C
100°C
95°C
181.
0-5
580.
418
950.
468
165
0.59
921
47.
350
9.76
30.
044
13.5
5811
1011
161.
3-5
590.
437
110
0.48
718
90.
619
264
4.61
06.
121
0.04
28.
514
1413
1314
2.1
-510
0.47
914
90.
529
234
0.66
030
12.
907
3.85
90.
039
5.38
221
2018
123.
3-5
600.
550
196
0.60
026
60.
744
334
1.82
62.
424
0.03
73.
393
2725
2210
5.2
-561
0.60
429
60.
654
406
0.78
549
41.
153
1.53
00.
035
2.15
435
3329
87.
6-5
620.
765
453
0.81
556
90.
988
704
0.70
80.
940
0.03
71.
339
4542
386
12.5
-563
0.91
465
30.
964
813
1.13
797
30.
445
0.59
00.
035
0.85
360
5651
421
-565
1.13
710
731.
187
1292
1.36
014
810.
300
0.39
90.
032
0.58
579
7468
234
-566
1.31
513
611.
365
1637
1.53
818
560.
184
0.24
40.
030
0.36
910
598
901
43-5
671.
470
2130
1.52
021
921.
756
2482
0.14
70.
195
0.03
10.
302
122
114
105
1/0
54-5
681.
618
2550
1.66
827
461.
903
3108
0.11
70.
156
0.03
00.
248
140
131
122
2/0
70-5
691.
802
2954
1.85
233
012.
088
3734
0.09
30.
125
0.03
00.
203
161
150
140
4/0
109
-746
2.16
736
152.
217
3955
2.45
345
920.
058
0.08
00.
029
0.14
021
620
218
8
37-102
Five Con
ductor Pow
er Cab
leGe
xol®Insulated
Extr
emel
y Fl
exib
le •
0.6
/1kV
• R
ated
110
°C
Man
ufac
ture
d by
Am
erCa
ble
Inco
rpor
ated
• 8
00-5
06-9
473
• 71
3-89
6-58
00 •
Fax
: 713
-849
-900
910
633
Wes
t Litt
le Y
ork
• Bl
dg. #
1 •
Suite
#10
0 •
Hou
ston
, TX
7704
1 •
ww
w. a
mer
cabl
e.co
m
Flexible Pow
er Cable – Five Co
nductor
Cable
dia
mete
rs s
how
n a
s n
om
inal are
subje
ct
to a
±5%
manufa
ctu
ring t
ole
rance
GEXO
L®is
a re
gist
ered
trad
emar
k of
Am
erCa
ble
Inco
rpor
ated
Ordering Gexol Oil & Gas Cables
Exam
ple:
•
5 co
nduc
tor
pow
er c
able
• 0.
6/1k
V•
#2 A
WG
• br
onze
arm
ored
& s
heat
hed
Amer
Cabl
e G
exol
O
il &
Gas
Pre
fixSp
ecifi
c Ca
ble
Num
ber
(fro
m c
hart
s)Ar
mor
Req
uire
men
tBS
– a
rmor
ed &
shea
thed
Blan
k –
no a
rmor
37–1
02– 566
BS
®
Oil & Gas Cables
See
page
2 fo
r St
rand
ing
Prof
ile
13
37-102
Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
InsulationGEXOL® cross-linked, flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.
JacketA black, arctic grade,flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580. Color code:IEEE 1580 Table 22
ConductorsSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.
Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580. Color code:IEEE 1580 Table 22
Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copper available by request.
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronze or tinned copper.
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
37-102
Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900914
GEXOL® is a registered trademark of AmerCable Incorporated
Armored andUnarmored Armored (B) Sheath (BS)
Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter Weight Ampacity
AWG Conductors 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.) 110°C 100°C 95°C16 4 -529 0.402 99 0.452 154 0.583 227 17 16 1616 5 -559 0.437 110 0.487 189 0.619 264 14 13 1316 7 -505 0.475 155 0.525 255 0.656 330 12 11 1116 8 -503 0.531 164 0.581 265 0.712 340 12 11 1116 10 -504 0.631 206 0.681 366 0.812 445 9 8 1116 16 -546 0.719 299 0.769 465 0.942 602 9 8 1116 20 -687 0.794 360 0.844 560 1.017 724 9 8 1116 24 -525 0.923 462 0.973 718 1.146 809 8 7 1116 37 -526 1.048 658 1.098 819 1.271 989 6 6 816 44 -577 1.173 807 1.223 980 1.396 1175 6 6 816 60 -527 1.298 1053 1.348 1256 1.521 1496 6 6 816 91 -581 1.548 1595 1.598 1896 1.833 2181 6 6 814 4 -509 0.438 126 0.488 213 0.619 262 27 25 2214 5 -510 0.479 149 0.529 234 0.660 301 21 20 1814 6 -511 0.539 182 0.589 264 0.720 335 21 20 1814 7 -521 0.539 205 0.589 297 0.720 377 19 18 1514 10 -512 0.691 280 0.741 406 0.914 515 14 13 1514 12 -585 0.713 307 0.763 428 0.936 558 14 13 1514 14 -523 0.749 415 0.799 540 0.972 665 14 13 1514 20 -513 0.916 560 0.966 812 1.139 876 14 13 1514 24 -571 1.013 615 1.063 892 1.236 1132 12 11 1514 30 -573 1.071 780 1.121 965 1.294 1180 12 11 1314 37 -514 1.153 876 1.203 1135 1.376 1405 11 10 1314 44 -574 1.293 1087 1.343 1260 1.516 1477 10 9 1114 91 -582 1.775 2200 1.825 2465 2.060 2855 10 9 1112 4 -517 0.486 168 0.536 256 0.668 323 33 31 2712 5 -560 0.550 196 0.600 266 0.744 334 27 25 2212 6 -547 0.611 280 0.661 405 0.792 500 27 25 2212 10 -518 0.771 369 0.821 500 0.994 629 17 16 1912 20 -519 1.022 701 1.072 890 1.245 1055 17 16 1912 24 -572 1.133 861 1.183 1167 1.356 1468 15 14 1912 37 -520 1.293 1262 1.343 1467 1.516 1677 13 12 16
Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance
Flexible Control Cable – Multi-Conductor
Ordering Gexol Oil & Gas CablesExample:
• Multi-Conductor control cable• 0.6/1kV• #12 AWG• bronze armored & sheathed
AmerCable Gexol Oil & Gas Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
37–102 – 519 BS
®
Oil & Gas Cables
See page 2 for Stranding Profile
15
GEXOL® is a registered trademark of AmerCable Incorporated
37-102
Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronzeor tinned copper.
ConductorSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.
Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245.Bronze standard. Tinned copper availableby request.
InsulationGEXOL® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110 of UL 1309/CSA 245.
JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.
PairsEach pair is twisted with a bare tinned drain wire. Each pair is shielded withpolyester-backed aluminum foil tape to afford100% coverage. Pair to pairisolation plus overall shield is provided.Pair Color code:Black-White
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.
Cable available with blue jacket or stripe to signify
intrinsically safe circuit.
37-102
Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
GEXOL® is a registered trademark of AmerCable Incorporated
37-102
Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900916
Armored andUnarmored Armored (B) Sheath (BS)
Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Pairs 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -601 0.336 63 0.386 123 0.486 17618 2 -602 0.551 131 0.601 204 0.732 33518 3 -603 0.581 163 0.631 265 0.762 34318 4 -604 0.630 195 0.680 317 0.801 41018 5 -605 0.685 243 0.735 395 0.900 51118 7 -606 0.742 340 0.792 457 0.957 57518 8 -607 0.800 388 0.850 521 1.015 75218 10 -608 0.976 495 1.026 699 1.199 87418 12 -609 1.011 581 1.061 780 1.234 98218 16 -645 1.121 748 1.171 833 1.344 118218 18 -641 1.181 824 1.231 1050 1.404 130018 24 -646 1.382 1069 1.432 1151 1.605 172016 1 -610 0.356 77 0.406 120 0.507 20316 2 -611 0.565 160 0.615 249 0.751 37716 3 -612 0.617 200 0.667 311 0.785 41016 4 -613 0.671 239 0.721 389 0.886 56916 5 -614 0.730 297 0.780 483 0.945 60916 7 -615 0.792 416 0.842 559 1.007 70316 8 -616 0.896 475 0.946 638 1.119 80316 10 -617 1.047 606 1.097 787 1.270 109816 12 -618 1.081 711 1.131 923 1.304 113816 16 -619 1.207 948 1.257 1231 1.422 151716 18 -626 1.265 1100 1.315 1260 1.488 157016 20 -688 1.327 1215 1.377 1476 1.552 189416 24 -699 1.482 1510 1.532 1625 1.767 206514 1 -620 0.386 97 0.436 151 0.537 19914 2 -621 0.621 202 0.671 315 0.802 48114 3 -622 0.658 251 0.708 391 0.881 51514 4 -623 0.721 301 0.771 469 0.944 63314 5 -624 0.791 374 0.841 608 1.013 78714 7 -625 0.905 524 0.955 704 1.128 88614 8 -630 0.979 498 1.029 803 1.202 101114 10 -627 1.148 747 1.198 1003 1.371 119614 12 -628 1.186 896 1.236 1203 1.409 1434
Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance
Flexible Instrumentation Cable – Individually Shielded Pairs
Ordering Gexol Oil & Gas CablesExample:
• Instrumentation cable• 0.6/1kV• #14 AWG• bronze armored & sheathed
AmerCable Gexol Oil & Gas Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
37–102 – 620 BS
VALUES:
#18 PairsCapacitance (nF/1000 feet) = 28Inductance (mH/1000) = 0.22Resistance (Ohms/1000 feet) = 7.21 (@ 20°C)
#16 PairsCapacitance (nF/1000 feet) = 32Inductance (mH/1000) = 0.20Resistance (Ohms/1000 feet) = 4.52 (@ 20°C)
#14 PairsCapacitance (nF/1000 feet) = 37Inductance (mH/1000) = 0.19Resistance (Ohms/1000 feet) = 2.85 (@ 20°C)
See page 2 for StrandingProfile
®
Oil & Gas Cables
17
37-102
Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C
www. amercable.com • e-mail: [email protected]
Ratings & Approvals (Other certifications pending)
� 110˚C Temperature Rating� American Bureau of Shipping (ABS)
99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)
E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)
91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable
(E111461) � United States Coast Guard
November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)
ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.
Features� High strand count conductors make this
product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.
� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.
� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.
� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.
� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
� Flame retardant: IEC 332-3 Category A and IEEE 1202.
� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).
� Optional braid armor of bronzeor tinned copper.
ConductorSoft annealed flexiblestranded tinned copper per IEEE 1580 Table 11.
Armor (Optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245.Bronze standard. Tinnedcopper available byrequest.
InsulationGEXOL® cross-linked, flame retardant polyolefin,meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.
JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlightresistant thermosettingcompound meeting UL 1309/CSA 245 and IEEE 1580.
TriadsEach triad is twisted with a bare tinned drain wire.Each triad is shielded with polyester-backed aluminum foil tape to afford100% coverage. Triad to triad isolation plus overallshielding is provided.Triad Color code:Black-White-Red
Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.
Cable available with blue jacket or stripe to signify
intrinsically safe circuit.
37-102
Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C
®
Oil & Gas Cables
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
37-102
Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900918
GEXOL® is a registered trademark of AmerCable Incorporated
#18 Triads
Capacitance – (nF/1000 feet) = 28
Inductance – (mH/1000) = 0.22
Resistance – (Ohms/1000 feet) = 7.21 (@ 20°C)
#16 TriadsCapacitance – (nF/1000 feet) = 32
Inductance – (mH/1000) = 0.20
Resistance – (Ohms/1000 feet) = 4.52 (@ 20°C)
VALUES:
Armored andUnarmored Armored (B) Sheath (BS)
Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Triads 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -647 0.354 75 0.404 144 0.504 19918 2 -681 0.649 183 0.699 290 0.872 38018 3 -648 0.688 190 0.738 305 0.911 39318 4 -682 0.755 281 0.805 408 0.978 55118 5 -649 0.871 286 0.921 419 1.094 56118 7 -650 0.947 409 0.997 565 1.170 72418 8 -683 1.026 515 1.076 680 1.249 87018 12 -640 1.244 766 1.294 965 1.467 119516 1 -668 0.376 86 0.426 155 0.558 21316 3 -669 0.735 218 0.785 338 0.958 46616 4 -698 0.807 410 0.857 530 1.030 70016 6 -676 1.012 630 1.062 750 1.235 95516 7 -670 1.012 710 1.062 835 1.235 105016 8 -677 1.090 729 1.140 876 1.330 1103
Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance
Flexible Instrumentation Cable – Individually Shielded Triads
Ordering Gexol Oil & Gas CablesExample:
• Instrumentation cable• 0.6/1kV • #18 AWG• bronze armored & sheathed
AmerCable Gexol Oil & Gas Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
37–102 – 682 BS
®
Oil & Gas Cables
See page 2 for Stranding Profile
37-102VFD
Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C
www. amercable.com • e-mail: [email protected] 19
ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.
Featuresn Specially engineered cable design produces
a longer cable life in VFD applications.n Overall braid plus foil shield is engineered
with 100% coverage and a surface transferimpedance <50 milliohms at 10MHz to contain EMI.
n Symmetrical insulated ground conductorsreduce induced voltage imbalances and carrycommon mode noise back to the drive.
n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable.
n Gexol’s lower dielectric constant (standardXLPEs, EPRs and other Type P insulation materials have higher dielectric constants)reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system.
n 2kV insulation thickness is used to resist thepotential 2-3x reflected voltages experienced in 600V VFD applications.
n Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
n Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.
n Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).
n Flame retardant: IEC 332-3 Category A and IEEE 1202.
n Suitable for use in Class I, Division 1 andZone 1 environments (armored andsheathed).
n Optional braid armor of bronze, aluminum or tinned copper.
Insulation (2kV)Gexol® cross-linked flameretardant polyolefin, meetingthe requirements for Type Pof IEEE 1580 and Type X110of UL 1309/CSA 245. Color: Gray with printedphase I.D. (Black-White-Red)
Power Conductors (x3)Soft annealed flexible strandedtinned copper per IEEE 1580Table 11.
Ground Conductors (x3)Soft annealed flexiblestranded tinned copper perIEEE 1580 Table 11.Gexol® insulation sized per UL 1277.Color: Green
JacketA black, arctic grade, flameretardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL1309/CSA 245 and IEEE 1580.
ShieldTinned copper basket weavewire armor per IEEE 1580 and UL 1309/CSA 245 plusaluminum/polyester tape providing 100% coverage.
Ratings & Approvalsn 110˚C Temperature Ratingn American Bureau of Shipping (ABS): 99-BT5905-Xn Transport Canada: 8700-20-2n Det Norske Veritas (DNV): E-6669, E-6388,
E-6390, E-6391n Lloyd’s Register of Shipping (LRS): 91/60333 (E6)n NVE: 95/1696, FALn UL Listed as Marine Shipboard Cable: (E111461)n Unarmored Cable is UL Listed as Type TC (E123629)n United States Coast Guard: November 2, 1987 / 9304
Other certifications pending
Gexol insulation has low capacitancefor superior performance in
VFD applications!
®
Oil & Gas Cables
Armor (Optional)Tinned copper basket weavewire armor per IEEE 1580
and UL 1309/CSA 245.
Sheath (Optional)A black, arctic grade, flame retardant, oil,
abrasion, chemical and sunlight resistant
thermosetting compound meeting UL 1309/CSA 245
and IEEE 1580.
Note: For armored versions the braid is placed betweenin inner jacket and outer sheath where it servesas both the EMI shield and armor.
37-102VFD
Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900920
GEXOL® is a registered trademark of AmerCable Incorporated
*Cable diameters are subject to a +/- 5% manufacturing tolerance
andhas a
low capacitance for superior performancein VFD applications!
Gexolis
flexible
110°C RatingsBased on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.
100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.
95°C Ratings Based on 4-3-4/Table 10 of the 2001 ABS MODU rules and a 45°C ambient.
90°C Ratings Based on ICEA S-75-381 Table H-1 for a single isolated cable in air with a 40°C ambient. Thisampacity is typically used for mining and other portable applications.
75°C Ratings Based on Table B.310.1 of the 2005 NEC for cables in raceway and a 30°C ambient.
VFD Cable Ampacity Ratings
®
Oil & Gas Cables
See page 2 for Stranding Profile
Size Nominal Weight Nominal Weight Nominal WeightAWG/ Part No. Diameter Per Part No. Diameter Per Part No. Diameter Perkcmil 37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. Size (AWG) 110˚C 100˚C 95˚C 90˚C 75˚C
14 -508VFD 0.622 194 -508BVFD 0.672 281 -508BSVFD 0.772 349 18 27 25 22 - 18
12 -516VFD 0.671 224 -516BVFD 0.721 321 -516BSVFD 0.795 383 18 33 31 27 - 24
10 -308VFD 0.725 308 -308BVFD 0.775 412 -308BSVFD 0.918 518 14 44 41 36 - 33
8 -309VFD 0.780 441 -309BVFD 0.830 565 -309BSVFD 0.973 616 14 56 52 48 - 43
6 -310VFD 0.910 570 -310BVFD 0.960 708 -310BSVFD 1.098 832 12 75 70 64 93 58
4 -312VFD 1.072 886 -312BVFD 1.125 1061 -312BSVFD 1.262 1128 12 99 92 85 122 79
2 -314VFD 1.215 1421 -314BVFD 1.271 1618 -314BSVFD 1.393 1712 10 131 122 113 159 105
1 -315VFD 1.340 1517 -315BVFD 1.395 1743 -315BSVFD 1.509 1836 10 153 143 131 184 121
1/0 -316VFD 1.443 1803 -316BVFD 1.493 2027 -316BSVFD 1.615 2137 10 176 164 152 211 145
2/0 -317VFD 1.572 2153 -317BVFD 1.622 2399 -317BSVFD 1.792 2660 10 201 188 175 243 166
3/0 -318VFD 1.750 2827 -318BVFD 1.800 3073 -318BSVFD 1.901 3133 8 234 218 202 270 189
4/0 -319VFD 2.053 3463 -319BVFD 2.103 3785 -319BSVFD 2.102 3864 8 270 252 235 321 223
262 -320VFD 2.193 4175 -320BVFD 2.243 4522 -320BSVFD 2.320 4695 6 315 294 267 365 254
313 -321VFD 2.370 4727 -321BVFD 2.420 5104 -321BSVFD 2.421 5326 6 344 321 299 408 287
373 -322VFD 2.501 5415 -322BVFD 2.551 5809 -322BSVFD 2.555 6091 6 387 361 334 451 315
444 -323VFD 2.670 6707 -323BVFD 2.721 7141 -323BSVFD 2.703 7422 6 440 411 372 499 350
535 -324VFD 2.972 7483 -324BVFD 3.022 7966 -324BSVFD 3.016 8504 6 498 443 418 - 390
646 -326VFD 3.164 8916 -326BVFD 3.214 9428 -326BSVFD 3.270 10034 4 553 516 470 - 431
777 -327VFD 3.388 10395 -327BVFD 3.438 10940 -327BSVFD 3.489 11877 4 602 562 529 473
Green InsulatedGrounding
Conductor (x3)
Unarmored ArmoredArmored &
Sheathed (BS)
Ampacity
Termination KitsAmerCable Systems offers pre-sized and
pre-formed terminationkit packages specifically
for VFD cable constructions
37-102VFD
Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C
37-105
Type MMV Medium Power CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
www. amercable.com • e-mail: [email protected]
ApplicationsAmerCable’s Type MMV marine mediumvoltage cables are for use aboard commercial ships, mobile offshoredrilling units (MODUs), and fixed orfloating offshore facilities.
Featuresn These cables utilize flexible
stranded conductors, braided shieldsand a braided armor (when armored)which make them very suitable forapplications involving repeated flexingand high vibration.
n These cables have a small minimumbending radius (6xOD for unarmoredcables and 8xOD for armored cables) for easy installation.
n Optional uninsulated groundingconductors sized per UL 1072.
n The increased flexibility of this cableallows for termination of one end and coiling on multiple module offshore platforms. Then coiling andterminating other end when modulesare mated at sea thereby reducinginstallation time.
n Passes IEC 332-3 Category A and IEEE 1202 flame tests.
Conductor ShieldA combination of semi-conducting tape andextruded thermosetting semi-conducting materialmeeting UL 1309, IEEE 1580 and UL1072.
Armor (optional)(Optional) 0.0126" bronze braid providing 88%minimum coverage meeting UL 1309 and IEEEStd. 45-1998.
JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistant thermosettingcompound meeting UL 1309, IEEE 1580 and UL 1072. Colored jackets for signifying differentvoltage levels are also available on special request(ie. yellow = 5kV, orange = 8kV and red = 15kV).
Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion,chemical, and sunlight resistant thermosettingcompound meeting UL 1309, IEEE 1580 and UL 1072. Colored jackets for signifying differentvoltage levels is also available on special request(ie. yellow = 5kV, orange = 8kv and red = 15kV).
Metallic Shield
Composite shieldconsisting of 0.0126" tinned copper braided with nylon providing 60% copper Shieldedcoverage meeting UL 1309, IEEE Std. 1580 and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need toremove the shield to findan underlying colored tape.
Insulation ShieldSemi-conducting tape, with overlap, for fast andeasy termination meeting UL 1309, IEEE 1580 and UL 1072.
ConductorsSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.
Insulation
Extruded thermosetting90°C Ethylene PropyleneRubber (EPR), meeting UL 1309 (Type E), IEEE 1580 (Type E) and UL 1072.
Grounding Conductor (optional)One uninsulated soft annealed flexible strandedtinned copper conductor per ASTM B 33 andsized according to Table 21.1 of UL 1072.
Ratings & Approvals� UL Listed as Marine Shipboard Cable (E111461)� American Bureau of Shipping (ABS)� Det Norske Veritas (DNV) Pending� Lloyd’s Register of Shipping (LRS) Pending� 90˚C Temperature Rating� Voltage Rating – 5kV to 15kV
(25kV available on request)
Termination KitsAmerCable recommendsRaychem’s HVT seriesterminations for single conductorconstructions and HVT-M seriesterminations for multi-conductorconstructions.
®
Oil & Gas Cables
21
HawkeGland Types Unarmored Armored & Sheathed
Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753
Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2
Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U(2 liter or > enclosures)
Zone 1 & 2
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)
8
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
7.6
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
394
562
-101
-102
-103
-104
-105
-106
-107
-108
-109
-110
-111
-112
-113
-114
-115
-116
-117
0.564
0.604
0.686
0.750
0.790
0.877
0.937
0.980
1.042
1.121
1.187
1.252
1.327
1.408
1.496
1.599
1.883
204
252
344
449
528
659
787
910
1086
1272
1467
1692
1968
2294
2672
3154
4414
1.282
0.822
0.566
0.361
0.296
0.245
0.202
0.278
0.141
0.122
0.108
0.095
0.086
0.077
0.070
0.065
0.054
0.054
0.050
0.044
0.041
0.040
0.039
0.038
0.037
0.035
0.034
0.033
0.032
0.032
0.031
0.030
0.030
0.029
0.751
0.836
0.918
0.981
1.064
1.108
1.168
1.212
1.274
1.353
1.419
1.484
1.559
1.706
1.793
1.881
2.169
401
502
622
748
894
1004
1160
1298
1496
1708
1926
2174
2476
2949
3361
3859
5255
0.061
0.058
0.051
0.047
0.047
0.045
0.043
0.042
0.040
0.038
0.037
0.036
0.035
0.035
0.034
0.033
0.033
1.288
0.830
0.573
0.367
0.303
0.250
0.207
0.173
0.146
0.127
0.112
0.099
0.090
0.082
0.075
0.069
0.057
80
107
141
186
214
247
285
328
381
435
486
544
606
682
767
865
1084
69
92
121
159
184
212
244
281
325
371
413
460
510
570
635
709
853
68
91
120
158
182
210
242
279
324
370
413
462
515
580
652
735
921
0.694
0.436
0.286
0.175
0.140
0.111
0.089
0.070
0.056
0.046
0.038
0.032
0.027
0.022
0.019
0.015
0.011
0.885
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.017
Unarmored
Single Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
394
562
-118
-119
-120
-121
-122
-123
-124
-125
-126
-127
-128
-129
-130
-131
-132
-133
0.656
0.738
0.801
0.884
0.929
0.989
1.032
1.094
1.173
1.239
1.304
1.379
1.460
1.548
1.651
1.935
283
378
486
604
702
835
956
1135
1324
1522
1750
2029
2359
2741
3186
4498
0.824
0.567
0.362
0.298
0.246
0.203
0.169
0.142
0.123
0.109
0.096
0.087
0.078
0.071
0.066
0.055
0.052
0.046
0.043
0.042
0.041
0.039
0.038
0.036
0.035
0.034
0.033
0.033
0.032
0.031
0.030
0.030
0.888
0.970
1.033
1.108
1.160
1.220
1.264
1.326
1.405
1.471
1.536
1.603
1.746
1.833
1.949
2.233
549
673
806
942
1072
1226
1363
1563
1779
1999
2250
2538
3012
3428
3944
5388
0.059
0.052
0.048
0.047
0.046
0.044
0.043
0.041
0.039
0.038
0.037
0.036
0.036
0.035
0.034
0.033
0.831
0.574
0.368
0.304
0.251
0.208
0.174
0.147
0.128
0.113
0.100
0.091
0.082
0.075
0.070
0.058
107
141
186
214
247
285
328
381
435
486
544
606
682
767
865
1084
92
121
159
184
212
244
281
325
371
413
460
510
570
635
709
853
91
120
158
182
210
242
279
324
370
413
462
515
580
652
735
921
0.436
0.286
0.175
0.140
0.111
0.089
0.070
0.056
0.046
0.038
0.032
0.027
0.022
0.019
0.015
0.011
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.017
Unarmored
Single Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &
Sheathed (BS) Ampacity
®
Oil & Gas Cables
22 Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-9009
See page 29 for MMV
Stranding Profile
www. amercable.com • e-mail: [email protected] 23
Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
394
562
-134
-135
-136
-137
-138
-139
-140
-141
-142
-143
-144
-145
-146
-147
-148
-149
0.710
0.792
0.898
0.938
0.983
1.043
1.086
1.148
1.227
1.293
1.358
1.433
1.460
1.602
1.767
1.989
317
417
565
648
751
884
1007
1189
1381
1584
1813
2095
2359
2814
3376
4587
0.826
0.569
0.365
0.300
0.247
0.204
0.171
0.143
0.124
0.110
0.097
0.088
0.078
0.072
0.067
0.055
0.054
0.047
0.045
0.044
0.042
0.040
0.039
0.038
0.036
0.035
0.034
0.033
0.032
0.032
0.032
0.031
0.942
1.016
1.129
1.170
1.214
1.274
1.318
1.380
1.459
1.524
1.582
1.719
1.758
1.888
2.065
2.275
603
725
916
1022
1140
1293
1432
1635
1854
2081
2318
2734
3034
3529
4181
5470
0.060
0.053
0.050
0.049
0.047
0.045
0.044
0.042
0.040
0.039
0.038
0.038
0.036
0.036
0.036
0.034
0.832
0.575
0.370
0.305
0.252
0.209
0.175
0.148
0.129
0.114
0.101
0.093
0.083
0.076
0.071
0.058
107
141
186
214
247
285
328
381
435
486
544
606
682
767
865
1084
92
121
159
184
212
244
281
325
371
413
460
510
570
635
709
853
91
120
158
182
210
242
279
324
370
413
462
515
580
652
735
921
0.436
0.286
0.175
0.140
0.111
0.089
0.070
0.056
0.046
0.038
0.032
0.027
0.022
0.019
0.015
0.011
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.017
Unarmored
Single Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
34
43
54
70
86
109
132
159
189
227
273
326
394
562
-150
-151
-152
-153
-154
-155
-156
-157
-158
-159
-160
-161
-162
-163
1.050
1.088
1.133
1.191
1.236
1.298
1.397
1.463
1.528
1.603
1.742
1.830
1.965
2.187
692
778
883
1024
1154
1343
1568
1778
2015
2313
2762
3165
3729
4930
0.369
0.303
0.251
0.208
0.174
0.146
0.128
0.113
0.100
0.091
0.082
0.075
0.070
0.057
0.049
0.047
0.045
0.044
0.042
0.040
0.039
0.038
0.037
0.036
0.036
0.035
0.034
0.033
1.269
1.308
1.352
1.410
1.456
1.518
1.616
1.744
1.809
1.884
2.024
2.112
2.246
2.468
1088
1186
1301
1462
1608
1817
2077
2422
2685
3014
3520
3960
4578
5870
0.053
0.051
0.049
0.047
0.046
0.044
0.042
0.042
0.041
0.040
0.039
0.038
0.037
0.036
0.373
0.308
0.255
0.212
0.178
0.150
0.131
0.117
0.104
0.095
0.086
0.079
0.073
0.060
186
214
247
284
327
378
431
481
536
598
672
754
848
1061
164
189
217
250
288
332
377
418
464
514
574
638
709
857
158
182
210
241
278
321
366
409
456
508
571
641
721
902
0.175
0.140
0.111
0.089
0.070
0.056
0.046
0.038
0.032
0.027
0.022
0.019
0.015
0.011
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.017
Unarmored
Single Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &
Sheathed (BS) Ampacity
Ordering Type MMV Medium Voltage CablesExample:
• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed
AmerCable TypeMMV Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
Ground ConductorG – with groundBlank – no ground
37–105 – 319 BS G
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
®
Oil & Gas Cables
See page 29 for MMV
Stranding Profile
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance ResistanceAWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
34
43
54
70
86
109
132
159
189
227
273
326
394
562
-164
-165
-166
-167
-168
-169
-170
-171
-172
-173
-174
-175
-176
-177
1.132
1.170
1.215
1.273
1.338
1.400
1.479
1.545
1.610
1.747
1.824
1.944
2.047
2.269
771
863
970
1112
1267
1461
1670
1884
2132
2541
2889
3350
3870
5083
0.370
0.305
0.252
0.209
0.176
0.148
0.129
0.114
0.101
0.093
0.084
0.077
0.071
0.058
0.050
0.049
0.047
0.045
0.044
0.042
0.040
0.039
0.038
0.038
0.037
0.036
0.035
0.034
1.352
1.390
1.434
1.492
1.558
1.620
1.761
1.827
1.892
2.029
2.106
2.226
2.329
2.551
1194
1299
1416
1578
1756
1971
2320
2561
2836
3301
3680
4191
4753
6057
0.055
0.053
0.051
0.049
0.047
0.046
0.044
0.043
0.042
0.041
0.040
0.039
0.038
0.036
0.375
0.309
0.256
0.213
0.179
0.151
0.133
0.118
0.105
0.096
0.087
0.080
0.074
0.061
186
214
247
284
327
378
431
481
536
598
672
754
848
1061
164
189
217
250
288
332
377
418
464
514
574
638
709
857
158
182
210
241
278
321
366
409
456
508
571
641
721
902
0.175
0.140
0.111
0.089
0.070
0.056
0.046
0.038
0.032
0.027
0.022
0.019
0.015
0.011
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.017
Unarmored
Single Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor
8
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
7.6
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
394
-301
-302
-303
-304
-305
-306
-307
-308
-309
-310
-311
-312
-313
-314
-315
-316
1.137
1.226
1.402
1.538
1.626
1.783
1.913
2.007
2.140
2.310
2.453
2.589
2.818
2.974
3.164
3.385
781
955
1307
1690
1974
2423
2884
3315
3937
4619
5319
6107
7280
8463
9814
11526
1218
1424
1824
2372
2692
3232
3749
4220
4899
5654
6549
7402
8684
9964
11407
13226
1.369
1.457
1.625
1.824
1.911
2.081
2.210
2.305
2.438
2.608
2.796
3.000
3.161
3.317
3.507
3.729
66
88
116
152
175
201
232
266
306
348
386
429
455
528
584
647
56
75
99
129
149
171
197
226
260
296
328
365
387
449
496
550
0.708
0.445
0.300
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.020
0.016
0.885
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.048
0.044
0.039
0.036
0.035
0.034
0.033
0.032
0.031
0.030
0.029
0.029
0.028
0.028
0.027
0.027
1.275
0.815
0.560
0.356
0.291
0.239
0.196
0.163
0.136
0.118
0.104
0.092
0.083
0.074
0.067
0.062
8
6
6
6
4
4
4
3
3
3
2
2
1
1
1
1/0
Unarmored
Three Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900924
®
Oil & Gas Cables
See page 29 for MMV
Stranding Profile
v2.08.1
www. amercable.com • e-mail: [email protected] 25
Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
-332
-333
-334
-335
-336
-337
-338
-339
-340
-341
-342
-343
-344
-345
1.454
1.630
1.829
1.916
2.012
2.141
2.236
2.369
2.539
2.680
2.885
3.036
3.210
3.400
1249
1639
2162
2467
2838
3327
3763
4417
5133
5870
6884
7959
9167
10554
1896
2359
2964
3306
3717
4259
4734
5443
6422
7227
8340
9491
10782
12261
1.740
1.916
2.114
2.202
2.297
2.427
2.521
2.654
2.888
3.031
3.235
3.380
3.552
3.742
88
116
152
175
201
232
266
306
348
386
429
455
528
584
75
99
129
149
171
197
226
260
296
328
365
387
449
496
0.445
0.300
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.020
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.048
0.043
0.040
0.038
0.037
0.036
0.035
0.033
0.032
0.032
0.031
0.030
0.030
0.029
0.820
0.564
0.359
0.294
0.242
0.199
0.166
0.139
0.121
0.106
0.094
0.085
0.076
0.069
6
6
6
4
4
4
3
3
3
2
2
1
1
1
Unarmored
Three Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
12.5
21
34
43
54
70
86
109
132
159
189
227
273
326
394
-317
-318
-319
-320
-321
-322
-323
-324
-325
-326
-327
-328
-329
-330
-331
1.338
1.514
1.650
1.800
1.895
2.025
2.119
2.252
2.422
2.565
2.704
2.930
3.096
3.267
3.512
1094
1462
1970
2263
2617
3100
3531
4162
4864
5581
6392
7582
8806
10137
11959
1589
2134
2725
3054
3454
3989
4458
5140
5913
6884
7760
9059
10366
11780
13708
1.561
1.799
1.998
2.085
2.181
2.310
2.404
2.537
2.707
2.914
3.054
3.280
3.439
3.611
3.855
88
116
152
175
201
232
266
306
348
386
429
455
528
584
647
75
99
129
149
171
197
226
260
296
328
365
387
449
496
550
0.445
0.300
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.020
0.016
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.028
0.025
0.046
0.041
0.038
0.037
0.036
0.034
0.033
0.032
0.031
0.030
0.030
0.029
0.029
0.028
0.028
0.818
0.562
0.357
0.293
0.241
0.198
0.165
0.138
0.119
0.105
0.093
0.084
0.075
0.068
0.063
6
6
6
4
4
4
3
3
3
2
2
1
1
1
1/0
Unarmored
Three Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &
Sheathed (BS) Ampacity
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
®
Oil & Gas Cables
Ordering Type MMV Medium Voltage CablesExample:
• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed
AmerCable TypeMMV Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
Ground ConductorG – with groundBlank – no ground
37–105 – 319 BS G
See page 29 for MMV
Stranding Profile
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
34
43
54
70
86
109
132
159
189
227
273
-346
-347
-348
-349
-350
-351
-352
-353
-354
-355
-356
2.157
2.239
2.335
2.461
2.559
2.691
2.749
2.881
3.021
3.183
3.357
2759
3073
3466
3991
4466
5150
5749
6483
7331
8380
9599
3697
4045
4477
5242
5764
6513
7348
8184
8856
9983
11285
2.443
2.524
2.620
2.810
2.910
3.041
3.152
3.287
3.365
3.527
3.701
156
178
205
234
269
309
352
389
432
456
528
133
151
174
199
229
263
299
331
367
388
449
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.042
0.040
0.039
0.037
0.036
0.035
0.034
0.033
0.032
0.031
0.031
0.361
0.296
0.244
0.201
0.168
0.141
0.122
0.107
0.095
0.086
0.077
6
4
4
4
3
3
3
2
2
1
1
Unarmored
Three Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &
Sheathed (BS) Ampacity
Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop OptionalAWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
34
43
54
70
86
109
132
159
189
227
273
-357
-358
-359
-360
-361
-362
-363
-364
-365
-366
-367
2.334
2.416
2.512
2.637
2.842
2.976
2.989
3.091
3.204
3.347
3.521
3125
3470
3874
4411
5206
5930
6412
6990
7897
8879
10144
4137
4515
5150
5748
6640
7430
7831
8529
9510
10560
11910
2.619
2.701
2.861
2.987
3.192
3.325
3.340
3.394
3.548
3.690
3.865
156
178
205
234
269
309
352
389
432
456
528
133
151
174
199
229
263
299
331
367
388
449
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.044
0.043
0.041
0.039
0.038
0.037
0.035
0.034
0.034
0.033
0.033
0.364
0.299
0.246
0.203
0.170
0.142
0.124
0.109
0.097
0.088
0.079
6
4
4
4
3
3
3
2
2
1
1
Unarmored
Three Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &
Sheathed (BS) Ampacity
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900926
Ordering Type MMV Medium Voltage CablesExample:
• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed
AmerCable TypeMMV Prefix
Specific Cable Number(from charts)
Armor RequirementBS – armored &
sheathedBlank – no armor
Ground ConductorG – with groundBlank – no ground
37–105 – 319 BS G
®
Oil & Gas Cables
See page 29 for MMV
Stranding Profile
www. amercable.com • e-mail: [email protected] 27
®
Oil & Gas Cables
v2.08.1
37-105VFD
Type MMV-VFDPower CableThree Conductor: 8kV – 15kV • 133% Insulation Level • Rated 90°C
ApplicationsA flexible, braid and foil shielded,power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications.
Featuresn Flexible stranded conductors and
braided shields. Suitable for applications involving repeated flexing and high vibration.
n Small minimum bending radius (8x OD) for easy installation.
n Insulation has a very low dielectricconstant. This allows for longeroutput cable distances andminimizes common mode current.
n Overall braid plus foil shield is engineered with 100% coverage anda surface transfer impedance <50milliohms at 10MHz to contain EMI.
n Symmetrical insulated ground conductors reduce induced voltageimbalances and carry common mode noise back to the drive.
n High strand count conductors andbraid shield design is much more flexible, easier to install and moreresistant to vibration than Type MC cable.
n Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).
n Flame retardant: IEC 332-3 Category A and IEEE 1202.
n Suitable for use in Class I, Division 1, and Zone 1 environments.
Conductors (3)Soft annealed flexible strandedtinned copper per IEEE 1580 Table 11.
Conductor ShieldA combination of semi-conducting tape and extruded thermosettingsemi-conducting materialmeeting UL 1309, IEEE 1580and UL1072.
Armor/EMI ShieldOverall tinned copper braid plus aluminum/polyestertape provides 100% coverage. This braid serves asboth an armor and EMI shield meeting both IEEE 1580and UL 1307/CSA 245.
JacketA black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580, and UL 1072. This jacket allows for isolation betweenthe insulation shields and overall shield. Shields canthen be terminated on oppostie ends to minimizecirculating currents.
Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580, and UL 1072. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = 15kV).
Insulation ShieldComposite shield consistingof 0.0126" tinned copperbraided with nylon providing 60% copperShielded coverage meetingUL 1309, IEEE Std. 1580,and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue,red) without the need toremove the shield to find anunderlying colored tape.
Insulation ShieldSemi-conducting layer meeting UL 1309, IEEE 1580 and UL 1072.Insulation
Extruded thermosetting90°C Ethylene PropyleneRubber (EPR), meetingUL 1309 (Type E), IEEE 1580 (Type E)and UL 1072.
Symmetrical InsulatedGrounding Conductors (3)Soft annealed flexible stranded tinned copper conductor per IEEE 1580 Table 11. Gexol Insulation sized per Table 23.2 of UL1072. Color: Green
Ratings & Approvalsn UL Listed as Marine Shipboard
Cable (E111461)n American Bureau of Shipping (ABS)n Det Norske Veritas (DNV) Pendingn Lloyd’s Register of Shipping (LRS)
Pendingn 90˚C Temperature Ratingn Voltage Rating – 8kV to 15kV
(25kV available on request)
Termination Kits
AmerCablerecommends
Raychem HVT-MSeries
Low smoke halogen-free jacket available on request.
Manufactured by AmerCable, Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328
®
Oil & Gas Cables
Single Inductive Voltage Green InsulatedSize Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop GroundingAWG/ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)
6421
1/02/03/04/0262313373444535
12.5213443547086
109132159189227273
-332TSVFD-333TSVFD-334TSVFD-335TSVFD-336TSVFD-337TSVFD-338TSVFD-339TSVFD-340TSVFD-341TSVFD-342TSVFD-343TSVFD-344TSVFD
1634207426253022337338264411509359936867781088559905
1.6871.8682.0712.1612.2622.3812.4892.6313.8573.0303.1643.3193.492
88116152175201232266306348386429455528
7599
129149171197226260296328365387449
0.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.024
0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.033
0.0480.0430.0400.0380.0370.0360.0350.0330.0320.0320.0310.0300.030
0.8200.5640.3590.2940.2420.1990.1660.1390.1210.1060.0940.0850.076
1010108886666444
Three Conductor Type MMV-VFD Marine Medium Voltage8kV • 133% Insulation Level
Ampacity
Ampacity
Single Inductive Voltage Green InsulatedSize Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop GroundingAWG/ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)
21
1/02/03/04/0262313373444
3443547086
109132159189227
-357TSVFD-358TSVFD-359TSVFD-360TSVFD-361TSVFD-362TSVFD-363TSVFD-364TSVFD-365TSVFD-366TSVFD
3231295940904615530661317074778787039912
2.4032.4682.5962.7142.8753.0283.2603.3633.5003.652
156178205234269309352389432456
133151174199229263299331367388
0.1840.1470.1170.0930.0740.0580.0480.0400.0340.028
0.2300.1840.1470.1170.0940.0750.0630.0530.0450.039
0.0440.0430.041
0.0390.038
0.0370.0350.0340.0340.033
0.3640.2990.2460.2030.1700.1420.1240.1090.0970.080
10888666644
Three Conductor Type MMV-VFD Marine Medium Voltage15kV • 133% Insulation Level
Ordering Type MMV-VFD Medium Voltage CablesExample:
• 3 conductor MMV-VFD power cable• 15kV• #2 AWG
AmerCable Type MMV-VFD Prefix
Specific CableNumber (from charts)
37–105 – 357TSVFD
Stranding Profile:See Page 29
www. amercable.com • e-mail: [email protected] 29
Ampacities are based on API RP 14F (June 1999)Table 4 or 5 for single conductor cables and Table3 for multi-conductor cables. The notes to thesetables are also applicable. Ampacities are alsobased on a 90°C conductor temperature and a45°C ambient temperature.
Inductive reactance and voltage drop values are based on a 90°C conductor temperature and 60 Hz operation. Values for single conductor cables are based on a symmetrical triangular configuration.
Please consult AmerCable on values for other configurations.
MMV Ampacities & Electrical Data
Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor
AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)
8
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111
37
61
133
133
209
266
342
418
532
646
777
925
1110
1332
1591
1924
2745
0.0201
0.0201
0.0177
0.0223
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
0.0201
16
26
41
66
83
106
133
168
212
262
313
373
444
535
646
777
1111
7.57
12.49
21.11
33.51
42.79
54.45
70.01
85.57
108.91
132.25
159.06
189.36
227.23
272.68
325.70
393.87
561.94
0.136
0.175
0.258
0.324
0.361
0.407
0.461
0.510
0.575
0.654
0.720
0.785
0.860
0.941
1.029
1.132
1.354
MMV Bend RadiusUnarmored Armored Armored & Sheathed
IEEE 45 6X Diameter 8X Diameter 8X Diameter
IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter
Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter
>1" (25mm)6X Diameter
37-105
Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C
MMV Stranding Profile
®
Oil & Gas Cables
Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.
Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.
30
Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable
A swollen orsplit cable jacket
due to drillingmud exposure
is a productivity
killer.
AmerCableoffers threelevels of mudresistance tomatch youroperatingconditions:
Standard, Advanced and
Ester Based Mud Resistant
www. amercable.com • e-mail: [email protected] 31
1 All results representative of finished cables (6 3/C, 14 7/C and 18 7 PR). Test data on file at AmerCable
Aging Requirements
90°C Rated Jacket
121±1°C
Air Oven 240 Hours
Oil Exposure
Resistance
After Oil Immersion at
121±1°C 18 Hours
Jacket Type Type N Type N Mud Resistant Jacket
Tensile Strength, Min, PSI 1800 1800 Pass
300 300 Pass
20 20 Pass
Elongation at Rupture, Min, %
Set, Max, %
Tensile Strength,
Minimum900 psi 900 psi Pass
50%
Actual
50%
ActualPass
80 80 Pass
60 60 Pass
100 130 Pass
Elongation at Rupture, %
Tensile Strength, % Retention
of Unaged, Min
Elongation at Rupture, %
Retention of Unaged, Min
Mechanical Water
Absorptionmg / in2
Weatherometer TestNo
RequirementPass PassPer UL 1581
TearNo
Requirement35 Passlb/in Thickness, Min
FT4/IEEE 1202 Flame
Exposure (UL-1685)Pass Pass Pass–
IEC 332-3 Flame
Exposure
No
Requirement
No
RequirementPass–
Table ISpecifications UL-1309
Table 4IEEE 1580Table 5-7
AmerCable TestingProgram1
World Class Mud ResistantJacket
Physical
Requirements –
Unaged
When standard mud resistance isn’t enough, AmerCable has aWorld Class Mud Resistant cable jacket designed to deliveroutstanding performance in the harshest operating conditions.Designed specifically for exposure to high temperature ESTERBASED drilling muds, this cable meets all the performancerequirements of industry standards UL 1309 and IEEE 1580for Type N jackets. When tested for prolonged exposure to themost aggressive ester based drilling muds, it easily passes the mud resistance requirements of NEK 606.
AmerCable’s ester based mud resistant cables were also testedagainst the requirements of UL 1309 and IEEE 1580 and theresults are shown in Table I.1 This product easily passed allthe requirements. Table II shows the results of this cablewhen aged in Baroid Petrofree® (Ester Based) drilling mud perNEK 606. All aging requirements were met. Additional testingdone on these cables show the jacket to pass cold impact at -20°C and cold bend at -40°C.
Table II
MUD Resistant –
NEK 606
Note: Tested for
Changes in Each Listed
Requirement
70°C, 56 Days
Elongation at Break ±25% Baroid Petrofree® (Ester Based) Pass
Tensile Strength ±25% Baroid Petrofree® (Ester Based) Pass
Volume Swelling Max 20% Baroid Petrofree® (Ester Based) Pass
Weight Increase Max 15% Baroid Petrofree® (Ester Based)
Baroid Petrofree® (Ester Based)
Pass
Oxygen Index Min 25% Pass
Requirements Mud Type Results
Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable
®
Oil & Gas Cables
32
Constructions:n 300V – 15kV AC
n AC & DC Power
n Composite Power & Control
n Instrumentation
n Thermocouple
n Fiber Optic
n Electro-Optic
Applications:n Service Loops
n Driller’s Console
n Mud Pump Controls
n 15kV Bridle Assembly
n Tender-to-PlatformBridle
n Ship-to-Shore Power
n Portable PowerGeneration
n Zone 1 (EX) Rated Cable Assemblies
n 300V – 15kV AC n DC Power n Instrumentation n Composite Power & Control n Thermocouplen Fiber Optic n Electro-Optic
(800) 506-9473 • (713) 896-5800E-mail: [email protected]
www.amercablesystems.com
(877) 506-3010 • (713) 469-3981E-mail: [email protected]
www.amerrig.com
TM
Top DriveService Loops
Precision EngineeredCable Assemblies
n Highly reliable cable assemblies custom builtand tested to spec
n Fast Delivery
n Job-site application evaluation and consultation
Fiber OpticCable Solutions
CableAssemblySolutions
Standard & Custom Designs
Offshore and Land-based
Shortest Lead Times
Outstanding Customer Serivce
Shortest Lead Times
Outstanding Customer Serivce
33
1_11© 2010, AmerCable Incorporated
10633 West Little York • Building #1 • Suite #100 • Houston, TX 77041 800-506-9473 • 713-896-5800 • Fax: 713-849-9009 • e-mail: [email protected] • www.amercable.com
®
Low smokehalogen-freefire resistantor flameretardant Type P cables.
SHF1, SHF2and NEK 606IEC cables
Precisionengineered cableassembliesfor hazardousand industrialapplications.
Top DriveService Loops &Top DriveServices
VFDCABLES
Crush andImpactResistant Type P cableswithoutexternalarmoring.
Foil shielded,power cablesengineered for use in variablefrequency AC driveapplications.
Available in severalconstructions
AmerCable is an ISO 9001 certified cable manufacturerthat combines leading-edge manufacturing technology,
innovative thinking, and high quality service to deliver the finest oil & gas cable andengineered cable assemblies available.
AmerCable serves the world from our Oil & Gas Group headquarters in Houston, Texas. Ourprofessional field engineers and sales force work withyou to create innovative, cost-effective project solutions.
What can you expect from AmerCable?n Fastest Lead Times in the Industry
n On-Time Delivery
n Professional Sales, Support and Service
n Productivity Solutions
n Global Cable Management