as-i, the simplest automation networking solution dated: 10/30/2008
TRANSCRIPT
Actuator Sensor interface (AS-i) is a simple wire reduction system
Easily replaces point to point wiring and complements existing higher level bus systems
Reduces wiring and eliminates multiple termination points
Connects inputs and outputs via a single two wire flat cable
Easy to install and commission
What is AS-i?
Point-To-Point Wiring
Each bit of data needs its own wire.
Power is run separately (more wires).
Additional I/O points require additional PLC I/O cards.
Additional PLC I/O cards may require the use of a larger PLC rack or multiple racks.
Smaller PLC rack.
Smaller enclosures.
Less wire.
Standardized patch cables.
Potential to eliminate J-boxes.
Simpler documentation.
Less commissioning time.
Less Material & Labor
One cable for many bits of data.
One master replaces many PLC I/O cards = less wiring.
Quick disconnect at modules vs. point-to-point terminations.
I/O modules connect easily to the bus via insulation displacement connectors (IDC).
Simple Installation & Expansion
Modules connect easily to the bus via insulation displacement connections (IDC).
Mechanically coded flat cable - AS-i and additional power supply
Insulation displacement connectors - simple & safe - protection class up to IP67, - cables reseals up to IP65
Simple Installation & Expansion
AS-Interfaceelectro-mechanics
piercing connectors
mechanical codedflat cable
Less wire means less opportunity for error, less places to look for errors.
Communication errors are captured by the master.
Indicating lights on modules and masters communicate system and module status.
Easier Troubleshooting
Reducing overall machine cost
Wiring Labor Cost X
Wire labeling Cost X
Machine Assembly Labor Costs X
Machine Testing Labor Cost X
Machine Disassemble Cost X
Shipping Cost X
Customer Site Start up/ Commisioning Labor X
Travel Cost X
Time = Money
AS-i can reduce up to 50% of the overall machine cost
100 meters max. length per segment. With repeaters up to 300M
AS-i transmits only 4 data bits per message.
Single two wire unshielded cable carries input power and communication
AS-i Specifications
Up to 62 node addresses per network 248 inputs and 248 outputs
Auto Address replacement
Topology free network
Max. of up to 10ms response time
Two methods to connect AS-i to your existing platform
Method 1: Direct PLC connection
Fits into standard card slot in a PLC rack
Replaces traditional I/O cards I/O are mapped directly to I/O tables Programmed and configured
through standard PLC software No 3rd party software needed Available for most PLC platforms
Control Integration
Two methods to connect AS-i to your existing platform
Method 2: Complements current fieldbus
networks
Gateway becomes a single node on the fieldbus network, up to 992 I/O points per gateway
Reduces the price per point for connecting sensors and actuators
Available for DeviceNet, Profibus, Ethernet /IP, Modbus TCP, and CanOpen
Control Integration
ifm Controller-e gateway
Large Integrated Display
Connection to Fieldbus(Ethernet IP connection shown)
Diagnostic LEDs
AS-i and 24 VDC connections
After selecting the platform, pick an AS-i power supply
An integral and required part of an AS-i system Specialty 30 VDC power supply use to couple the master data for
transmission over the AS-i cable 2.8, 4 and 8 Amp versions available Provides power to all input devices and modules on the system
AS-i power supply
AS-i power supply
SmartLine
Compact
New ClassicLine Airbox
ProcessLineCabinet
PCB
Family of I/O modules
Choosing the correct I/O module to fit your application
Up to 4 inputs and 4 outputs
Analog inputs/outputs available in 4-20mA or 0-10V
Solid-state outputs protected against short circuits
and reverse polarity
Integrated addressing port
Inputs to be supplied either by the AS-i network or
24 VDC externally
Relay outputs versions available; rated up to 230 V
LED indication for short circuit and power
DIN rail mount
Connection via removable screw terminals,
Combicons
Control Cabinet Modules
Mounting technology does not require tools for installation
Three directions of rotation for flat cable
DIN rail mount
Up to 4 inputs and 4 outputs
Up to 2 analog (4-20mA) inputs
1 or 2 amp rated outputs available Digital inputs and outputs with LEDs for status
indication Integrated addressing port allows setup while
connected
New ClassicLine Field Modules
Mounting technology does not require tools for installation
Three directions of rotation for flat cable
DIN rail mount
Up to 4 inputs per Pneumatic module
Different valve types include 3/2, 5/2, 5/3 way Digital inputs and outputs with LEDs for status
indication Integrated addressing port allows setup while
connected
New ClassicLine Airbox Modules
Low profile design
Up to 4 inputs and 4 outputs per module
Fully potted units holds up to harsh environments
Increase resistance to shock and vibration
High amperage outputs rated for 2 amps Digital inputs and outputs with LEDs for status
indication Module base included
Compact Modules
IP69K protection rating
Up to 4 inputs and 3 outputs
Up to 4 analog (4-20mA) inputs
Quick mounting with only one screw
Full 316 Stainless Steel housing
Ecolab tested to resistance to common cleaning
agents found in the food industries
ProcessLine Modules
Benefits to Equipment builders
Reduces engineering time Reduces BOM cost Easy commissioning for new machines Easy trouble shooting No additional software
Benefits to End Users
Reduces maintenance cost Easy troubleshooting Easy expansion of existing
systems in house Training seminars offered by ifm efector