Valor Fireplaces • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com April 2019 1/2 Retrofit Applications - Concept H3 1000J Existing wall finish (combustible or non-combustible) Existing combustible framing Existing combustible header Existing hearth or floor. May be combustible material provided it is no higher than the base of the appliance. Required trim Backing plate (with ventilation slot) Note: Installers to verify all clearances to existing combustible materials are adequate before installing this appliance. Remote handset wall holder Wall switch 1000J heater Top or rear venting Mantel (see Installation Manual) The Reduced Clearance versions of the H3 backing plates are specifically designed for retrofit applications where an existing fireplace is being removed, and the existing wall finish and cavity remain. These backing plates incorporate a ventilation slot that allows for a lower combustible header height of 33”, and combustible wall finishes from 31” of the base of the appliance. Reduced Clearance backing plates DO NOT ADJUST for additional finishes applied later.

Upload: others

Post on 10-Oct-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: April 2019 1/2 Retrofit Applications - Concept€¦ · Retrofit Applications - Dimensions H3 1000J 237/16 596 mm 311/8 791 mm lectrical Inlet oint ptional 1270B emote Blower it outlet

Valor Fireplaces • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333

www.valorfireplaces.com

April 20191/2

Retrofit Applications - ConceptH3 1000J

Existing wall finish (combustible or non-combustible)

Existing combustible framing

Existing combustible header

Existing hearth or floor. May be combustible material provided it is no higher than the base of the appliance.

Required trim

Backing plate (with ventilation slot)

Note: Installers to verify all clearances to existing combustible materials are adequate before installing this appliance.

Remote handset wall holder

Wall switch1000J heater

Top or rear venting

Mantel (see Installation Manual)

The Reduced Clearance versions of the H3 backing plates are specifically designed for retrofit applications where an existing fireplace is being removed, and the existing wall finish and cavity remain. These backing plates incorporate a ventilation slot that allows for a lower combustible header height of 33”, and combustible wall finishes from 31” of the base of the appliance. Reduced Clearance backing plates DO NOT ADJUST for additional finishes applied later.

Page 2: April 2019 1/2 Retrofit Applications - Concept€¦ · Retrofit Applications - Dimensions H3 1000J 237/16 596 mm 311/8 791 mm lectrical Inlet oint ptional 1270B emote Blower it outlet

Valor Fireplaces • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333

www.valorfireplaces.com

April 20192/2

Retrofit Applications - DimensionsH3 1000J

23-7

/16”

[596

mm

]

31-1

/8” [

791

mm

]ElectricalInlet Point

Optional 1270RBK Remote Blower Kit outlet

Gas LineAccess Point

Optional 1270RBK Remote Blower Kit outlet

Stand-Offs

CenterLine

4 x 6-5/8” dia.venting

Header

6-5/8” dia. Ventingfield-convertiblefrom top to rear outlet

Center of vent

1-1/2”[38 mm]

3-5/16”[85 mm]

9-1/

2”[2

42 m

m]

15”

[381

mm

]

28-7

/16”

[722

mm

]

17-3

/8” [

441

mm

]

34-1/16” [865 mm]

35-13/16” [909 mm]

23-1/4” [590 mm]

27-7/8” [709 mm]

33” [

838

mm

]M

inim

um h

eade

r hei

ght

Front ViewLeft Side View Right Side View

Top View