apm30 installation guide

Upload: lauris-jurisons

Post on 14-Apr-2018

338 views

Category:

Documents


2 download

TRANSCRIPT

  • 7/30/2019 APM30 Installation Guide

    1/13

    1

    HUAWEI TECHNOLOGIES CO., LTD.

    www.huawei.com

    Huawei Confidential

    Security Level:2008-4-6

    APM30 Installation Guide

    HUAWEI TECHNOLOGIES CO., LTD. Page 2Huawei Confidential

    Overview of APM30

    APM30

    cabinet

    Extended

    battery

    cabinet

    For user

    devices

    For batteries

  • 7/30/2019 APM30 Installation Guide

    2/13

    2

    HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential

    Installation Procedure

    HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential

    Installing the Base

    Expansion bolt

  • 7/30/2019 APM30 Installation Guide

    3/13

    3

    HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential

    Installing the Extended Battery Cabinet

    Using the fireproof clay

    HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential

    Installing the APM30 Cabinet

  • 7/30/2019 APM30 Installation Guide

    4/13

    4

    HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential

    Installing the PMU and the PSU (1)

    PMU

    HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential

    PMU

    PSU

    Communication cable

    PMU monitoring cable

    Installing the PMU and the PSU (2)

  • 7/30/2019 APM30 Installation Guide

    5/13

    5

    HUAWEI TECHNOLOGIES CO., LTD. Page 9Huawei Confidential

    Installing the PGND Cable of the APM30

    Grounding busbar of

    the APM30 cabinet

    Cable hole of the

    APM30 cabinet for the

    AC input power cable

    Cable hole of the

    extended batterycabinet

    PGND cable between

    APM30 cabinet and the

    extended battery cabinet

    Grounding busbar of the

    extended battery cabinet

    HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential

    Installing the AC Input Power Cable of the APM30

    AC input power cable

    L wire of the AC

    input power cable

    N wire of the AC

    input power cable

  • 7/30/2019 APM30 Installation Guide

    6/13

    6

    HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential

    Installing the PGND Cable of the BBU3806

    PGND cable

    PGND cable

    HUAWEI TECHNOLOGIES CO., LTD. Page 12Huawei Confidential

    Installing the Power Cable of the Active BBU3806 (1)

    Note: Four signal wires of the power cable need to be connected.

    Four signal wires

    Blue wire and black wire

    of the power cable

  • 7/30/2019 APM30 Installation Guide

    7/13

    7

    HUAWEI TECHNOLOGIES CO., LTD. Page 13Huawei Confidential

    Active BBU3806

    Blue wire and

    black wire

    Installing the Power Cable of the Active BBU3806 (2)

    Four signal wires

    HUAWEI TECHNOLOGIES CO., LTD. Page 14Huawei Confidential

    Installing the Power Cable of the Standby BBU3806

    Note: Four signal wires need to be cut when the power cable is used

    for the standby BBU3806.

    Blue wire and black wire

    Standby BBU3806

  • 7/30/2019 APM30 Installation Guide

    8/13

    8

    HUAWEI TECHNOLOGIES CO., LTD. Page 15Huawei Confidential

    Installing the Power Cable of the RRU3801C (1)

    Blue wire and black wire

    of the power cable

    Blue wire and black wire

    of the power cable

    HUAWEI TECHNOLOGIES CO., LTD. Page 16Huawei Confidential

    Grounding the shielding

    layer of the power cable

    Installing the Power Cable of the RRU3801C (2)

  • 7/30/2019 APM30 Installation Guide

    9/13

    9

    HUAWEI TECHNOLOGIES CO., LTD. Page 17Huawei Confidential

    Installing the Inter-BBU3806 Cable

    Inter-BBU3806 cable

    HUAWEI TECHNOLOGIES CO., LTD. Page 18Huawei Confidential

    Installing the E1/T1 Cable of the BBU3806

    DB44 male

    connector of

    the E1/T1 cable

    E1/T1 cable

    Cable hole for the signal cable

    Grounding theshielding layer of

    the E1/T1 cable

  • 7/30/2019 APM30 Installation Guide

    10/13

    10

    HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential

    Installing the CPRI Optical Cable Between the BBU and the RRU

    CPRI optical cable

    Using the fireproof clay

    HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential

    Installing the Door Status Sensor Cable

    Door status sensor cable

  • 7/30/2019 APM30 Installation Guide

    11/13

    11

    HUAWEI TECHNOLOGIES CO., LTD. Page 21Huawei Confidential

    Installing the Batteries of the Extended Battery Cabinet

    12 V 50 Ah battery

    NEG(-) power cable

    RTN(+) power cable

    HUAWEI TECHNOLOGIES CO., LTD. Page 22Huawei Confidential

    RTN(+) power cable

    RTN(+) power cable

    NEG(-) power cable

    NEG(-) power cable

  • 7/30/2019 APM30 Installation Guide

    12/13

    12

    HUAWEI TECHNOLOGIES CO., LTD. Page 23Huawei Confidential

    Sealing the Cable Holes

    Cable hole for the PGND cable

    and the AC input power cable

    of the APM30

    Cable hole for the E1/T1 cable,

    CPRI optical cables, and the power

    cables of the RRU3801C

    HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential

    Installation Check

    Check whether the protection grounding cable is reliably grounded.6

    Check whether the power cables are correctly and securely connected.5

    Check whether the cabinet is collided to injury and if the paint is intact.

    If there is injury, repaint it immediately to prevent corrosion.

    4

    Check whether there is no redundant material in the cabinet. If any, clear it.3

    Check whether all bolts are tightened with flat washers and spring washers.2

    Check whether the cabinet stands upright stably.1

    ItemSN

  • 7/30/2019 APM30 Installation Guide

    13/13

    13

    HUAWEI TECHNOLOGIES CO., LTD.

    www.huawei.com

    Huawei Confidential

    Security Level:2008-4-6

    Thank You

    www.huawei.com