EN0000DE00EN_0000 © 2005 Siemens AG 1 AP 1120 Siemens AP 1120 Contents 1 AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3 AMO usage in the HiPath 4000 V2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4 Settings in the AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.1 Checking the loaded AP 1120 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.1.1 With DHCP resp. known IP-Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.1.2 Without DHCP for the first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.4.2 Preparation for Loading AP 1120 Software (Flashing) . . . . . . . . . . . . . . . . . 12 1.4.2.1 Loading with DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1.4.2.2 Loading the AP without DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 1.4.3 Settings of the HiPath 4000 V2.0 data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 1.4.4 General actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Upload: renato-guimaraes

Post on 10-Jul-2016

217 views

Category:

Documents


1 download

DESCRIPTION

Configuração de AP 1120 para ramais analógicos Hipath 4000

TRANSCRIPT

Page 1: ap1120_rei

AP 1120 Siemens

AP 1120

Contents1 AP 1120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 AMO usage in the HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.4 Settings in the AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.4.1 Checking the loaded AP 1120 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.4.1.1 With DHCP resp. known IP-Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.4.1.2 Without DHCP for the first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.4.2 Preparation for Loading AP 1120 Software (Flashing) . . . . . . . . . . . . . . . . . 121.4.2.1 Loading with DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.4.2.2 Loading the AP without DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231.4.3 Settings of the HiPath 4000 V2.0 data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371.4.4 General actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

EN0000DE00EN_0000© 2005 Siemens AG

1

Page 2: ap1120_rei

2

AP 1120Siemens

EN0000DE00EN_0000© 2005 Siemens AG

Page 3: ap1120_rei

AP 1120 Siemens

1 AP 1120

1.1 Feature description

The AP 1120 supports the connection of Group 3 Fax devices, analog Modems and voice ter-minals via IP. The installation is done via the board STMI2 (Q2316-X / - X10) as HG3530 (FC-TID=3) in the HiPath 4000 V2.0. It is also possible to use the AP 1120 on a HiPath 3000 with H323v3 and SIP. In the HiPath 4000 V2.0 the Codec G.711 is supported. The AP 1120 is ad-ministered with the Tool “Unit Management Network (UMN)”. All settings, which are necessa-ry for the HiPath 4000 V2.0, and Software-Updates have to be done by this UMN-Tool.

1.2 Indicators and connectors

Ready In Use LAN Power(green) (orange) (green) (green)

Ready: Is ON, if the AP 1120 is registered at the HG3550 (PABX-Address and Subs- criber number must be set).

In Use: Is ON, if one of the two device ports are busy (Port 1 or/and Port 2).

LAN: Is ON (or blinking), if there is a connection to the IP network (Layer 1).

Power: Is ON, if the AP 1120 is supplied by the power-supply.

EN0000DE00EN_0000© 2005 Siemens AG

3

Page 4: ap1120_rei

4

AP 1120Siemens

Analog connectors (Port 1 left, Port 2right)

Default settingButton

Computer Network Power con-nector

Analog connector: G3 Fax devices resp. analog Modems can be connected.

DefaultSettingButtonPressed for:

Action Comments

Ready

LEDs

In Use

Pattern

LAN Power

2 to 5 seconds

AP 1120 reboot

No changes are made to the AP 1120 settings.

Off Off Off Blink

5 to 10seconds

AP 1120 reboot in Recovery Mode

Sets the AP 1120 IP address to its default value in the MIB and restarts the unit.

Blink Blink Blink Blink

10 to 15seconds

AP 1120 reboot in Factory Re-set Mode

Deletes the persis-tent MIB values, creates a new con-figuration file with the default factory values, then re-starts the unit.

On On On On

EN0000DE00EN_0000© 2005 Siemens AG

Page 5: ap1120_rei

AP 1120 Siemens

Computer: A 10/100 BaseT Ethernet RJ-45 connector that can be connected into the net-work card of a computer. In this case, the HiPath AP1120 acts as a small Ether-net switch. It is possible to use either a cross-over or straight Ethernet cable toconnect in the Computer connector. The Computer connector performs auto-matic MDI / MDIX detection, meaning that it adapts to the type of cable connectedto it.

Network: A 10/100 BaseT Ethernet RJ-45 connector for access to a LAN, WAN or compu-ter. It can also be used as remote power feeding and is IEEE 802.3af compliantand Power DSine certified. It is possible to use either a cross-over or straightEthernet cable to connect in the Network connector. The Network connector per-forms automatic MDI / MDIX detection, meaning that it adapts to the type of cableconnected to it.

1.3 AMO usage in the HiPath 4000 V2.0

● Check resp. add the number of HG3530- boards

DISPLAY-DIMSU:TYPE=SYSTEM;ADD-DIMSU:TYPE=SYSTEM,STMIHFA2=10;

● Add the STMIHFA2 board

ADD-BCSU:MTYPE=PER,LTU=1,SLOT=6,PARTNO=Q2316-X,FCTID=3;

● Set the STMIHFA2 board data

ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=6,SMODE=NORMAL,IPADDR=1.30.11.40,NETMASK=255.255.255.0;

● Add subscriber G3-Fax / Voice terminal / Modem

ADD-COSSU:NEWCOS=41,INFO="41 NON VOICE DEVICE";CHANGE-COSSU:TYPE=COS,COS=41,AVCE=TA&TNOTCR&CDRSTN&CDRINT&RKOABS&COSXCD&TTT;CHANGE-COSSU:TYPE=COS,COS=41,AFAX=TA&TNOTCR&BASIC&MSN&MULTRA;CHANGE-COSSU:TYPE=COS,COS=41,ADTE=TA&TNOTCR&BASIC&MSN&MULTRA;

ADD-SBCSU:STNO=2425,OPT=OPTI,CONN=IP2,PEN=1-1-6-10,DVCFIG=OPTIIP&ANAFAX or ANADTE,COS1=41,COS2=41,LCOSV1=11,LCOSV2=11,LCOSD1=11,LCOSD2=11,DPLN=0,ITR=0,SSTNO=N,SPDI=0,SECR=N,INS=Y,ALARMNO=8,CALLOG=NONE;

ANAFAX for G3 Fax device or Voice terminalANADTE for Modem

EN0000DE00EN_0000© 2005 Siemens AG

5

Page 6: ap1120_rei

6

AP 1120Siemens

1.4 Settings in the AP 1120

1.4.1 Checking the loaded AP 1120 software

● Start Unit Management Network (UMN) and connect with the Unit Manager.

1.4.1.1 With DHCP resp. known IP-Address

● Device scanning

The AP 1120 must be loaded with the CorNet-IP software. If the AP 1120 is not loa-ded with the right software, a flash action is necessary (see “Loading AP 1120 Soft-ware (Flashing)”). For flashing an AP1120 the Tool UMN and a TFTP software is necessary on the Admin-PC.

Password:8749H323

EN0000DE00EN_0000© 2005 Siemens AG

Page 7: ap1120_rei

AP 1120 Siemens

Enter IP-Address ran-ge and start the scanoperation.

Select AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

7

Page 8: ap1120_rei

8

AP 1120Siemens

1.4.1.2 Without DHCP for the first installation

● Connect the AP 1120 with the Admin-PC

Connect the AP 1120, Port “COMPUTER”, with the Admin-PC directly (straight or crossed over cable can be used). Change the IP-Address of your PC, e.g. to 192.168.0.20 with Sub-net-Maske 255.255.255.0.

The Default IP-Address of the AP 1120 is 192.168.0.1.

Select the AP 1120 and check the loaded software.

EN0000DE00EN_0000© 2005 Siemens AG

Page 9: ap1120_rei

AP 1120 Siemens

● Set the AP 1120 IP-Address to “Default”

● Device scanning

Start a Reboot in “Recovery Mode” . To do this, press and hold the “Default Setting Button” between 5 and 10 seconds, until all LEDs start blinking.

EN0000DE00EN_0000© 2005 Siemens AG

9

Page 10: ap1120_rei

10

AP 1120Siemens

Enter IP-Address192.168.0.1 and startscan operation.

Select AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

Page 11: ap1120_rei

AP 1120 Siemens

Select AP 1120 and check the loaded Software.

EN0000DE00EN_0000© 2005 Siemens AG

11

Page 12: ap1120_rei

12

AP 1120Siemens

1.4.2 Preparation for Loading AP 1120 Software (Flashing)

The Tool “Unit Management Network (UMN)” must be installed on the Admin-PC.

The directory-/file-structure of the TFTP-Server (PC):

If an AP 1120 is changed from H323 resp. SIP to CorNet-IP the loaded software (H323 / SIP) is downloaded again before the CorNet-IP-Software can be transfered. If it is an Upgrade of a CorNet-IP version to a newer one the download of the same software is not necessary. After a Software change from H323/SIP to CorNet-IP a “Factory Reset” must be executed !!!

Only an AP 1120 with Software H323 v4 can be migrated to CorNet-IP v1 !!!

EN0000DE00EN_0000© 2005 Siemens AG

Page 13: ap1120_rei

AP 1120 Siemens

1.4.2.1 Loading with DHCP function

● Start Unit Management Network (UMN) and connect with the Unit Manager.

● Device scanning

Password:8749H323

EN0000DE00EN_0000© 2005 Siemens AG

13

Page 14: ap1120_rei

14

AP 1120Siemens

Enter IP-Address ran-ge and start the scanoperation.

Select AP 1120

Control the scanningtime for the single IP-Addresses.

EN0000DE00EN_0000© 2005 Siemens AG

Page 15: ap1120_rei

AP 1120 Siemens

● Configure the Software Download Server

Right mouse key

EN0000DE00EN_0000© 2005 Siemens AG

15

Page 16: ap1120_rei

16

AP 1120Siemens

The IP-Address of theTFTP-Servers (PC):1.30.21.2

Enter the directory ofthe new Software.

EN0000DE00EN_0000© 2005 Siemens AG

Page 17: ap1120_rei

AP 1120 Siemens

● Start the TFTP-Server (in this example: 3cDaemon)

Configure the TFTP-Server

EN0000DE00EN_0000© 2005 Siemens AG

17

Page 18: ap1120_rei

18

AP 1120Siemens

● Start Software Download

Process: Click with the right mouse key on the AP and select “Download Software(Abrupt)”;

Select AP

EN0000DE00EN_0000© 2005 Siemens AG

Page 19: ap1120_rei

AP 1120 Siemens

● The Software is transfered to the AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

19

Page 20: ap1120_rei

20

AP 1120Siemens

● Display the status of the Download-process

If there was a Software change from H323/SIP to CorNet-IP, a “Factory Reset” has to be started (see “Indicators and connectors”) !!!

Right mouse key;select“Edit SNMP”;

EN0000DE00EN_0000© 2005 Siemens AG

Page 21: ap1120_rei

AP 1120 Siemens

● Delete the AP 1120 from the Unit Manager

● Scan the AP 1120 again

Enter IP address ran-ge and start the scanoperation.

Start device scanning

Select the AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

21

Page 22: ap1120_rei

22

AP 1120Siemens

● Check the Software version

Select the AP 1120 and check the loaded Software.

EN0000DE00EN_0000© 2005 Siemens AG

Page 23: ap1120_rei

AP 1120 Siemens

0.0.0.1 Loading the AP without DHCP function

● Connect the AP 1120 with the Admin-PC

Connect the AP1120 with the Admin-PC directly (straight or crossed over cable is possib-le). Change the IP-Address of the Admin-PC, e.g. to 192.168.0.20 with Subnet mask 255.255.255.0.

● Set the AP 1120 IP-Address to “Default”

● Start the Unit Management Network (UMN) and connect to the Unit Manager.

● Device scanning

The default IP-Address of the AP 1120 is 192.168.0.1.

Start a Reboot in “Recovery Mode”. To do this, press the “Default Setting Button” between 5 to10 seconds, until all LEDs start to blink.

Password:8749H323

EN0000DE00EN_0000© 2005 Siemens AG

23

Page 24: ap1120_rei

24

AP 1120Siemens

Enter IP-Adresse192.168.0.1 and startscanning operation.

Select AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

Page 25: ap1120_rei

AP 1120 Siemens

Select AP 1120 and check the loaded Software.

EN0000DE00EN_0000© 2005 Siemens AG

25

Page 26: ap1120_rei

26

AP 1120Siemens

● Change the AP 1120 settings

IP-Address of theTFTP-Server (PC) is:1.30.21.2

Enter the directory ofthe new Software.

EN0000DE00EN_0000© 2005 Siemens AG

Page 27: ap1120_rei

AP 1120 Siemens

● AP 1120 Restart

Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)” or “Restart (Graceful)”;

Select AP

EN0000DE00EN_0000© 2005 Siemens AG

27

Page 28: ap1120_rei

28

AP 1120Siemens

● Delete the AP 1120

Connect the AP 1120 to the customer LAN (Port “NETWORK”) and change the IP-Address of the Admin-PC Network card !!!

EN0000DE00EN_0000© 2005 Siemens AG

Page 29: ap1120_rei

AP 1120 Siemens

● Device scanning

Enter IP-Address ran-ge and start the scanoperation.

Control the scanningtime of the single IP-Addresses.

EN0000DE00EN_0000© 2005 Siemens AG

29

Page 30: ap1120_rei

30

AP 1120Siemens

Select AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

Page 31: ap1120_rei

AP 1120 Siemens

● Start the TFTP-Server (in this example: 3cDaemon)

Configure the TFTP-Server

EN0000DE00EN_0000© 2005 Siemens AG

31

Page 32: ap1120_rei

32

AP 1120Siemens

● Start the Software Download

Process: Click with the right mouse key on the AP and select “Download Software(Abrupt)”;;

Select AP

EN0000DE00EN_0000© 2005 Siemens AG

Page 33: ap1120_rei

Siemens

● Software is transfered to the AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

33

Page 34: ap1120_rei

34

AP 1120Siemens

● Display the Status of the Download operation

If there was a Software change from H323/SIP to CorNet-IP, a “Factory Reset” has to be started (see “Indicators and connectors”) !!!

Right mouse key;select “Edit SNMP”;

EN0000DE00EN_0000© 2005 Siemens AG

Page 35: ap1120_rei

AP 1120 Siemens

● Delete the AP 1120

● Scan the devices again

Enter the IP-Addressrange and start thescan operation.

Start the device scan-ning

Select the AP 1120

EN0000DE00EN_0000© 2005 Siemens AG

35

Page 36: ap1120_rei

36

AP 1120Siemens

● Check the Software version

Select the AP 1120 and check the loaded Software.

EN0000DE00EN_0000© 2005 Siemens AG

Page 37: ap1120_rei

AP 1120 Siemens

0.0.1 Settings of the HiPath 4000 V2.0 data

● Set Host-IP (STMI2 address)

Enter IP addresse of theSTMI2 board (HG3530)

Enter subscriber number

EN0000DE00EN_0000© 2005 Siemens AG

37

Page 38: ap1120_rei

38

AP 1120Siemens

EN0000DE00EN_0000© 2005 Siemens AG

Page 39: ap1120_rei

AP 1120 Siemens

● Set Port data

Europe: a-LawUSA: u_Law

EN0000DE00EN_0000© 2005 Siemens AG

39

Page 40: ap1120_rei

40

AP 1120Siemens

● Restart the AP 1120

Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)”;

EN0000DE00EN_0000© 2005 Siemens AG

Page 41: ap1120_rei

AP 1120 Siemens

0.0.2 General actions

● AP 1120 Restart

Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)” or “Restart (Graceful)”;

EN0000DE00EN_0000© 2005 Siemens AG

41

Page 42: ap1120_rei

42

AP 1120Siemens

● Backup the AP 1120 data

To backup the AP 1120 data, a file with the name MacXXXXXX.cfg is created on the Admin-PC (Upload). This file can be restored during trouble shooting or AP 1120 change (Download). So the AP 1120 has not be configured again in case of error.

EN0000DE00EN_0000© 2005 Siemens AG

Page 43: ap1120_rei

AP 1120 Siemens

EN0000DE00EN_0000© 2005 Siemens AG

43

Page 44: ap1120_rei

44

AP 1120Siemens

● Restore AP 1120 data

EN0000DE00EN_0000© 2005 Siemens AG