Contents1 AP 1120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 AMO usage in the HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.4 Settings in the AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1 Checking the loaded AP 1120 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.4.1.1 With DHCP resp. known IP-Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.4.1.2 Without DHCP for the first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.4.2 Preparation for Loading AP 1120 Software (Flashing) . . . . . . . . . . . . . . . . . 121.4.2.1 Loading with DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.4.2.2 Loading the AP without DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231.4.3 Settings of the HiPath 4000 V2.0 data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371.4.4 General actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
EN0000DE00EN_0000© 2005 Siemens AG
1
2
AP 1120Siemens
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
1 AP 1120
1.1 Feature description
The AP 1120 supports the connection of Group 3 Fax devices, analog Modems and voice ter-minals via IP. The installation is done via the board STMI2 (Q2316-X / - X10) as HG3530 (FC-TID=3) in the HiPath 4000 V2.0. It is also possible to use the AP 1120 on a HiPath 3000 with H323v3 and SIP. In the HiPath 4000 V2.0 the Codec G.711 is supported. The AP 1120 is ad-ministered with the Tool “Unit Management Network (UMN)”. All settings, which are necessa-ry for the HiPath 4000 V2.0, and Software-Updates have to be done by this UMN-Tool.
1.2 Indicators and connectors
Ready In Use LAN Power(green) (orange) (green) (green)
Ready: Is ON, if the AP 1120 is registered at the HG3550 (PABX-Address and Subs- criber number must be set).
In Use: Is ON, if one of the two device ports are busy (Port 1 or/and Port 2).
LAN: Is ON (or blinking), if there is a connection to the IP network (Layer 1).
Power: Is ON, if the AP 1120 is supplied by the power-supply.
EN0000DE00EN_0000© 2005 Siemens AG
3
4
AP 1120Siemens
Analog connectors (Port 1 left, Port 2right)
Default settingButton
Computer Network Power con-nector
Analog connector: G3 Fax devices resp. analog Modems can be connected.
DefaultSettingButtonPressed for:
Action Comments
Ready
LEDs
In Use
Pattern
LAN Power
2 to 5 seconds
AP 1120 reboot
No changes are made to the AP 1120 settings.
Off Off Off Blink
5 to 10seconds
AP 1120 reboot in Recovery Mode
Sets the AP 1120 IP address to its default value in the MIB and restarts the unit.
Blink Blink Blink Blink
10 to 15seconds
AP 1120 reboot in Factory Re-set Mode
Deletes the persis-tent MIB values, creates a new con-figuration file with the default factory values, then re-starts the unit.
On On On On
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
Computer: A 10/100 BaseT Ethernet RJ-45 connector that can be connected into the net-work card of a computer. In this case, the HiPath AP1120 acts as a small Ether-net switch. It is possible to use either a cross-over or straight Ethernet cable toconnect in the Computer connector. The Computer connector performs auto-matic MDI / MDIX detection, meaning that it adapts to the type of cable connectedto it.
Network: A 10/100 BaseT Ethernet RJ-45 connector for access to a LAN, WAN or compu-ter. It can also be used as remote power feeding and is IEEE 802.3af compliantand Power DSine certified. It is possible to use either a cross-over or straightEthernet cable to connect in the Network connector. The Network connector per-forms automatic MDI / MDIX detection, meaning that it adapts to the type of cableconnected to it.
1.3 AMO usage in the HiPath 4000 V2.0
● Check resp. add the number of HG3530- boards
DISPLAY-DIMSU:TYPE=SYSTEM;ADD-DIMSU:TYPE=SYSTEM,STMIHFA2=10;
● Add the STMIHFA2 board
ADD-BCSU:MTYPE=PER,LTU=1,SLOT=6,PARTNO=Q2316-X,FCTID=3;
● Set the STMIHFA2 board data
ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=6,SMODE=NORMAL,IPADDR=1.30.11.40,NETMASK=255.255.255.0;
● Add subscriber G3-Fax / Voice terminal / Modem
ADD-COSSU:NEWCOS=41,INFO="41 NON VOICE DEVICE";CHANGE-COSSU:TYPE=COS,COS=41,AVCE=TA&TNOTCR&CDRSTN&CDRINT&RKOABS&COSXCD&TTT;CHANGE-COSSU:TYPE=COS,COS=41,AFAX=TA&TNOTCR&BASIC&MSN&MULTRA;CHANGE-COSSU:TYPE=COS,COS=41,ADTE=TA&TNOTCR&BASIC&MSN&MULTRA;
ADD-SBCSU:STNO=2425,OPT=OPTI,CONN=IP2,PEN=1-1-6-10,DVCFIG=OPTIIP&ANAFAX or ANADTE,COS1=41,COS2=41,LCOSV1=11,LCOSV2=11,LCOSD1=11,LCOSD2=11,DPLN=0,ITR=0,SSTNO=N,SPDI=0,SECR=N,INS=Y,ALARMNO=8,CALLOG=NONE;
ANAFAX for G3 Fax device or Voice terminalANADTE for Modem
EN0000DE00EN_0000© 2005 Siemens AG
5
6
AP 1120Siemens
1.4 Settings in the AP 1120
1.4.1 Checking the loaded AP 1120 software
● Start Unit Management Network (UMN) and connect with the Unit Manager.
1.4.1.1 With DHCP resp. known IP-Address
● Device scanning
The AP 1120 must be loaded with the CorNet-IP software. If the AP 1120 is not loa-ded with the right software, a flash action is necessary (see “Loading AP 1120 Soft-ware (Flashing)”). For flashing an AP1120 the Tool UMN and a TFTP software is necessary on the Admin-PC.
Password:8749H323
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
Enter IP-Address ran-ge and start the scanoperation.
Select AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
7
8
AP 1120Siemens
1.4.1.2 Without DHCP for the first installation
● Connect the AP 1120 with the Admin-PC
Connect the AP 1120, Port “COMPUTER”, with the Admin-PC directly (straight or crossed over cable can be used). Change the IP-Address of your PC, e.g. to 192.168.0.20 with Sub-net-Maske 255.255.255.0.
The Default IP-Address of the AP 1120 is 192.168.0.1.
Select the AP 1120 and check the loaded software.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Set the AP 1120 IP-Address to “Default”
● Device scanning
Start a Reboot in “Recovery Mode” . To do this, press and hold the “Default Setting Button” between 5 and 10 seconds, until all LEDs start blinking.
EN0000DE00EN_0000© 2005 Siemens AG
9
10
AP 1120Siemens
Enter IP-Address192.168.0.1 and startscan operation.
Select AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
●
Select AP 1120 and check the loaded Software.
EN0000DE00EN_0000© 2005 Siemens AG
11
12
AP 1120Siemens
1.4.2 Preparation for Loading AP 1120 Software (Flashing)
The Tool “Unit Management Network (UMN)” must be installed on the Admin-PC.
The directory-/file-structure of the TFTP-Server (PC):
If an AP 1120 is changed from H323 resp. SIP to CorNet-IP the loaded software (H323 / SIP) is downloaded again before the CorNet-IP-Software can be transfered. If it is an Upgrade of a CorNet-IP version to a newer one the download of the same software is not necessary. After a Software change from H323/SIP to CorNet-IP a “Factory Reset” must be executed !!!
Only an AP 1120 with Software H323 v4 can be migrated to CorNet-IP v1 !!!
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
1.4.2.1 Loading with DHCP function
● Start Unit Management Network (UMN) and connect with the Unit Manager.
● Device scanning
Password:8749H323
EN0000DE00EN_0000© 2005 Siemens AG
13
14
AP 1120Siemens
Enter IP-Address ran-ge and start the scanoperation.
Select AP 1120
Control the scanningtime for the single IP-Addresses.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Configure the Software Download Server
Right mouse key
EN0000DE00EN_0000© 2005 Siemens AG
15
16
AP 1120Siemens
The IP-Address of theTFTP-Servers (PC):1.30.21.2
Enter the directory ofthe new Software.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Start the TFTP-Server (in this example: 3cDaemon)
Configure the TFTP-Server
EN0000DE00EN_0000© 2005 Siemens AG
17
18
AP 1120Siemens
● Start Software Download
Process: Click with the right mouse key on the AP and select “Download Software(Abrupt)”;
Select AP
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● The Software is transfered to the AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
19
20
AP 1120Siemens
● Display the status of the Download-process
If there was a Software change from H323/SIP to CorNet-IP, a “Factory Reset” has to be started (see “Indicators and connectors”) !!!
Right mouse key;select“Edit SNMP”;
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Delete the AP 1120 from the Unit Manager
● Scan the AP 1120 again
Enter IP address ran-ge and start the scanoperation.
Start device scanning
Select the AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
21
22
AP 1120Siemens
● Check the Software version
Select the AP 1120 and check the loaded Software.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
0.0.0.1 Loading the AP without DHCP function
● Connect the AP 1120 with the Admin-PC
Connect the AP1120 with the Admin-PC directly (straight or crossed over cable is possib-le). Change the IP-Address of the Admin-PC, e.g. to 192.168.0.20 with Subnet mask 255.255.255.0.
● Set the AP 1120 IP-Address to “Default”
● Start the Unit Management Network (UMN) and connect to the Unit Manager.
● Device scanning
The default IP-Address of the AP 1120 is 192.168.0.1.
Start a Reboot in “Recovery Mode”. To do this, press the “Default Setting Button” between 5 to10 seconds, until all LEDs start to blink.
Password:8749H323
EN0000DE00EN_0000© 2005 Siemens AG
23
24
AP 1120Siemens
Enter IP-Adresse192.168.0.1 and startscanning operation.
Select AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
●
Select AP 1120 and check the loaded Software.
EN0000DE00EN_0000© 2005 Siemens AG
25
26
AP 1120Siemens
● Change the AP 1120 settings
IP-Address of theTFTP-Server (PC) is:1.30.21.2
Enter the directory ofthe new Software.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)” or “Restart (Graceful)”;
Select AP
EN0000DE00EN_0000© 2005 Siemens AG
27
28
AP 1120Siemens
● Delete the AP 1120
Connect the AP 1120 to the customer LAN (Port “NETWORK”) and change the IP-Address of the Admin-PC Network card !!!
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Device scanning
Enter IP-Address ran-ge and start the scanoperation.
Control the scanningtime of the single IP-Addresses.
EN0000DE00EN_0000© 2005 Siemens AG
29
30
AP 1120Siemens
Select AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Start the TFTP-Server (in this example: 3cDaemon)
Configure the TFTP-Server
EN0000DE00EN_0000© 2005 Siemens AG
31
32
AP 1120Siemens
● Start the Software Download
Process: Click with the right mouse key on the AP and select “Download Software(Abrupt)”;;
Select AP
EN0000DE00EN_0000© 2005 Siemens AG
Siemens
● Software is transfered to the AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
33
34
AP 1120Siemens
● Display the Status of the Download operation
If there was a Software change from H323/SIP to CorNet-IP, a “Factory Reset” has to be started (see “Indicators and connectors”) !!!
Right mouse key;select “Edit SNMP”;
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Delete the AP 1120
● Scan the devices again
Enter the IP-Addressrange and start thescan operation.
Start the device scan-ning
Select the AP 1120
EN0000DE00EN_0000© 2005 Siemens AG
35
36
AP 1120Siemens
● Check the Software version
Select the AP 1120 and check the loaded Software.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
0.0.1 Settings of the HiPath 4000 V2.0 data
● Set Host-IP (STMI2 address)
Enter IP addresse of theSTMI2 board (HG3530)
Enter subscriber number
EN0000DE00EN_0000© 2005 Siemens AG
37
38
AP 1120Siemens
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
● Set Port data
Europe: a-LawUSA: u_Law
EN0000DE00EN_0000© 2005 Siemens AG
39
40
AP 1120Siemens
● Restart the AP 1120
Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)”;
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
0.0.2 General actions
● AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select“Restart (Abrupt)” or “Restart (Graceful)”;
EN0000DE00EN_0000© 2005 Siemens AG
41
42
AP 1120Siemens
● Backup the AP 1120 data
To backup the AP 1120 data, a file with the name MacXXXXXX.cfg is created on the Admin-PC (Upload). This file can be restored during trouble shooting or AP 1120 change (Download). So the AP 1120 has not be configured again in case of error.
EN0000DE00EN_0000© 2005 Siemens AG
AP 1120 Siemens
EN0000DE00EN_0000© 2005 Siemens AG
43
44
AP 1120Siemens
● Restore AP 1120 data
EN0000DE00EN_0000© 2005 Siemens AG