“Inadequacy of traditional test methods for detection

of non-hermetic energetic components”

Page 2: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

George R. Neff & Jimmie K. NeffIsoVac Engineering, Inc., Glendale, CA

Barry T. NeyerPerkinElmer Optoelectronics, Miamisburg, OH

Karl K. RinkUniversity of Idaho, Moscow, ID

Page 3: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

The Authors Competency

Many decades of experience in leak detection and failure analysisManufacture of ordnance devicesFundamental research in ordnance device designs and performanceAcademic research in leak testing theory and applicationPreparation of Military Standards & Commercial Test Specifications

Page 4: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

The Hermeticity Test Problem

Poor understanding of leak test theoryMisapplication of test methodologiesFailure to understand device geometryCommitting to traditional practicesIgnoring MIL-STD limitationsLack of Field FeedbackInferior failure analysisWeak Statistical recordkeeping

Page 5: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

The Hermeticity Callouts

Most Ordnance Devices have “Seal-Test” callouts of:Visible to 5 x 10-6 std cm3/sec

(The “Gross-Leak Rate Range”)

Many Ordnance Devices have Small & Zero-Cavities that are:

0.01 cm3 through 0.000001cm3

Page 6: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Test Methodology Reviewed

Helium Mass Spectrometry

Radioisotope Test Method

Red Dye Penetrant Failure Analysis

Page 7: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Typical Leak-Rate Distribution

Over 98% of leakers

Page 8: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Test Methods

Helium ‘Mass-Spec’ leak test method, (HMS)

Being misapplied for “Gross-Leak” testingRequires “Caution” with small ordnance devicesMIL-STDs limit HMS to Fine leak testing only, and not allowed for Gross leak testing.Unreliable to detect “gross leaks” in “Small & Zero-Cavity” devices

Page 9: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Helium Mass Spectrometry

“Back-Pressurization”Various bomb times and pressuresParts measured IndividuallyParts are evacuated prior to measurementHelium is lost during evacuation

Tracer-Gas loss During Evacuation:0.0001cm3 cavity with 10-4 std cc/s leak- 99.99% of Helium tracer gas in 10 sec.

Page 10: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Helium Mass Spectrometry

A “Leakage passage” Usually has short length and a ‘passage’ volume: < 10-5

cm3

Therefore: With a 10-4 cm3/s leak rate: “Helium is gone in Less than 1 second”.Then: Detectable helium is only from:“Interparticulate” cavities or “He Dissolved

in Binders”, very slowly released.Result is an “Indicated-Leak” less than the

spec, and an “escaped leaker”.

Page 11: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Radioisotope (Kr85) leak testing

Called out in MIL-STDs for Gross & Fine leak testing

Testing small (0.02cm3) to large cavities.

Testing “Small” & “Zero-cavities” with charcoal gettering.

Page 12: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Radioisotope Test Method“Back-Pressurization”

0.01% Kr85 tracer-gas mixture

Measured “In-Place” (In Device Cavity)

Detectability: ~ 1011 molecules Kr85

Bomb Times:“Gross-Leaks” ~36 sec. (> 5 x 10-6)“Fine-Leaks” ~6 min.

Page 13: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Technical theory of the testThe gamma rays from Kr85 gas trapped within a leaker, will penetrate the walls of normal devices, and are easily detected by the scintillation crystal at the counting stations.

Page 14: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Dye Penetrant Failure Analysis

Purpose”Verification of gross leakageDetectability to ~ 1 x 10-7 std cm3/sIsolation of leak sites

Glass header cracksGlass-to-metal sealsWeld defects

Destructive test

Page 15: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Vacuum Decay Equation

Pt = Po e -kt

Where:Pt =Partial press Kr85 at time “t”Po =Original partial press Kr85 k= leak rate (std cm3/s)

cavity vol. cm3

t = time in vacuum (sec)

Page 16: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

The “Gettering” Technology

“Charcoal Gettering” of Kr851. Steam Activated Charcoal2. High surface area: 500m2/gm3. Mixed with ordnance4. One Particle of Charcoal:

0.003” size, 0.243 µgm, vol. ~10-7 cm3

“Provides 133 mm2 surface area”.

Page 17: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

“Gettering” of Kr85

“Steam-Activated Coconut-Shell Charcoal”

1. “Adsorbs” Kr85 tracer gas2. Holds Kr85 by van der Waals forces3. Does not effect ordnance materials4. Adsorbs 27% by wt of water5. Assures detection of ‘wide open leak’6. Used in 50+ million Ordnance parts/year

Page 18: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Leak Test Standards

MIL-STD-883MIL-STD-750MIL-STD-202

MIL-STD-S-19500MIL-13474c-Squibs

S-113 Ordnance+ Others, (Military & Company Specs)

Mostly: based on MIL-STD 202

Page 19: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Mil Std. 883

Bubble or Dye Penetrant Test

0 10-510-8

Leak Rate std-cc/sec

Leak Test Ranges for U.S. Specification Callouts

Gross Leak Fine Leak

Radioisotope Gross

Radioisotope Gross Leak Test & Fine Leak TestHelium Test

Page 20: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Bubble or Dye Penetrant Test

0 10-5

Leak Rate std-cc/sec

Radioisotope Gross Leak Test & Fine Leak Test

Leak Test Ranges for U.S. Specification Callouts

Gross Leak Fine Leak

Mil Std. 750

Helium Test

Page 21: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Bubble or Dye Penetrant Test

0 10-5

Leak Rate std-cc/sec

Leak Test Ranges for U.S. Specification Callouts

10-8Gross Leak Fine Leak

Mil Std. 202

Helium testRadioisotope Test

Page 22: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

MIS-13474C (Missile Inspection Systems-Squibs)

0 10-5

Leak Rate std-cc/sec

Leak Test Ranges for U.S. Specification Callouts

Radioisotope Gross Leak Test

10-8Gross Leak Fine Leak

Radioisotope Fine Leak Test

Page 23: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Red-Dye in “Header Gross-Leak”

Page 24: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Pin-Glass “Gross-Leak”

Bridge-wire

Header

Glass

Pin Red-Dye penetrant

Page 25: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

“Pin-Glass Gross-leaks”

Page 26: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

“Fungus-Growth” on Ordnance

Page 27: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Charcoal mixed in ordnance

Compressed ZPP

Bridge-Wire Impression

Charcoal Particles

Page 28: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Impulse Cartridge

Page 29: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Residue of corroded bridge-wire

Page 30: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Need to Establish a Guaranteed Leak Test Method

Leak testing of energetic products is inherently more complicated than a simple vacuum decay equation impliesNeed to research known leakers with proposed approach to ensure that the method works.

Investigate devices with known leaks in glass-to-metal seals and defective welds.Verify that the method can detect such leaks

Page 31: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

Use of Academia

University of Idaho has developed some Unique Engineering Capabilities

Fully equipped for “Fundamental Research”Skilled in Ordnance technologiesSophisticated Ballistic testingAll leak testing methodologiesHermetic seal mechanics studiesGas and Moisture transfer through leaksOrdnance material behavior

Page 32: “Inadequacy of traditional test methods for detection of non ......Bubble or Dye Penetrant Test 0 10-5 Leak Rate std-cc/sec Leak Test Ranges for U.S. Specification Callouts 10-8

The authorsThank You for Your Time