  • Wall Ties and Restraint Fixings for the Construction Industry

    CI/SfB Xt6

    April 2006

  • 2

  • Ancon designs and manufactures high integrity steel products for

    the construction industry. Through continuous programmes of

    new product development, inward investment and employee

    advancement, the company is committed to maintaining the

    highest level of customer service within a dynamic and

    challenging industry.

    Wall ties and restraint fixings are an essentialelement in the stability of masonry panels.

    Ancon manufactures fixings in a variety oflengths and types for restraining brickwork,blockwork and stonework. Restraints can befixed to concrete and structural steelwork aswell as any type of masonry.

    The range of standard ties provides a solutionfor all types of wall construction and manyproducts can be delivered in 24 hours. These items are shown in red italics.

    Ancon fixings are manufactured fromAustenitic stainless steel. Grade 1.4301 (304)is used in the vast majority of applications. All ties will be supplied to this specification unless Ancon is notified otherwise.

    Cavity Wall Tie Selection 4-5Installation Guidance 6

    Part E of the Building Regulations 6

    Ties for Brick-to-Block Construction 7

    Ties for Thin-Joint Blockwork 8

    Ties for Timber Frames 8

    Ties for Steel Studwork 9

    Standard Wall Ties 10

    Bespoke Wall Tie References 11

    Vertical Movement Joints 12

    Frame Cramps 13

    Pre-Fixing Aids 13

    Cast-in Slots, Channels & Fastrack 14

    Wall Starter Systems 15

    Two-Part Ties 16

    Ties for Bubble Foil Insulation 16

    Briclok, Column Ties & Slip-Brick Ties 17

    Restraints for Stone Cladding 18-21

    Head Restraints 22-23

    Remedial Wall Ties 24-25

    Masonry Reinforcement 26

    Other Ancon Products 27

    3

    BS EN ISO 9001 : 2000FM12226

    Masonry Support Systems

    Windposts and Lintels

    Wall Ties and Restraint Fixings

    Channel and Bolt Fixings

    Tension Systems

    Shear Load Connectors

    Reinforcing Bar Couplers

    Reinforcement Continuity Systems

    Punching Shear Reinforcement

    Insulated Balcony Connectors

    Flooring and Formed Sections

    Special Fabrications

    Refractory Fixings

  • Wall Ties and Restraint Fixings

    4

    CAVITY WALL TIE SELECTIONThe selection and spacing of wall ties dependon many factors. These include type ofbrick/block to be tied, cavity width, type andheight of building, location, and design life.There are several documents which need to be consulted.

    BS 5628-1: 2005 Code of Practice for theUse of MasonryThis code provides recommendations onlength of tie, embedment, density andpositioning. Masonry-to-masonry ties areclassified as Types 1 to 4; the relevantclassification is determined by strength,function and use. Minimum declared values fortensile and compression capacities are listedfor each Type.

    DD140: Part 2: 1987: Recommendationsfor the Design of Wall TiesMuch of the information in DD140: Part 2 hasnow been updated and incorporated intoeither BS 5628-1: 2005 or BS EN 845-1:2003. The classification of timber frame ties,Types 5 and 6, is still covered by DD140: Part 2.

    BS EN 845-1: 2003 Specification forAncillary Components for Masonry Part 1: Ties, Tension Straps, Hangers and BracketsThis European Standard specifies therequirements for wall ties used forinterconnecting masonry and for connectingmasonry to beams, columns or other parts ofthe building. Materials, tolerances, tie typesand the requirements for declared values, areall covered in this standard.

    Type 1Ancon ST1

    Type 2Staifix RT2

    BS 5628-1 Wall Ties

    Wall Tie withInsulationRetaining Clip

    Tensile Tensile Compressive CompressiveMinimum Mortar Load Load at 1mm Load Load at 1mm

    Type Class and Capacity Displacement Capacity Displacementof Tie Designation (N) (N) (N) (N)

    1 M12 (i) 5000 1667 5000 1667M2 (iv) 2500 833 2500 833

    2 M2 (iv) 1800 600 1300 433

    3 M2 (iv) 1100 367 800 267

    4 M2 (iv) 650 217 450 150

    5 M2 (iv) 600* 200 425* 142

    6 M2 (iv) 630* 210 440* 147

    Inner leafInsulationOuter leaf

    Minimum Requirements for Wall Ties to BS 5628-1: 2005 and DD140-2

    Selection of Wall Ties to BS 5628-1: 2005

    Maximum Building Geographical

    Type Application Density Height Location

    Type 1 Heavy duty tie suitable for most building 2.5 ties/m2 Any Suitable for most sites.sizes and types. Not very flexible and 3-4 ties/m Height However, for relatively tall ornot recommended for applications at unbonded unusually shaped buildings inwhere there is expected to be excessive edges vulnerable areas, the tiedifferential movement between leaves provision should be calculated

    Type 2 General purpose tie for domestic and As Type 1 15m Basic wind speed up tosmall commercial buildings. May be 31m/s and altitude not moresuitable for buildings exceeding than 150m above sea level15 metres if shown to be adequateby calculation

    Type 3 Basic wall tie generally as Type 2 above As Type 1 15m Basic wind speed limited to25m/s and altitude not morethan 150m above sea level

    Type 4 Light duty wall tie suitable for As Type 1 10m Basic wind speed limited tobox-form domestic dwellings with 25m/s and altitude not moreleaves of similar thickness than 150m above sea level

    Type 5* Timber frame tie suitable for 4.4 ties/m2 15m Basic wind speed limited todomestic houses and small 25m/s and altitude not morecommercial developments of up than 150m above sea levelto two storeys

    Type 6* Timber frame tie suitable for 4.4 ties/m2 15m Basic wind speed limited todomestic houses and small 25m/s and altitude not morecommercial developments of up than 150m above sea levelto three storeys

    31m/s

    31m/s

    25m/s

    Type 4Staifix HRT4

    *Based on characteristic failure loads to DD140: Part 2

    * Based on DD140: Part 2For complete information refer to BS 5628-1: 2005 and DD140: Part 2: 1987

    Information taken from BS 6399-2: 1997 Code ofPractice for Wind Loads

  • 5Density & Positioning of Ties For walls in which both leaves are 90mm orthicker, ties should be used at not less than2.5 per square metre (900mm horizontal x450mm vertical centres). Ties should be evenlydistributed over the wall area, except aroundopenings, and should preferably be staggered.

    In cases where insulation board is incorporatedwithin the cavity and restrained by ties withinsulation retaining clips, it may be necessaryto reduce the horizontal spacing of the ties to600mm. At vertical edges of an opening,unreturned or unbonded edges, and verticalexpansion joints, additional ties should beused at a rate of one per 300mm height,located not more than 225mm from the edge.A typical layout is shown below. Various detailsincorporating debonding ties at verticalmovement joints are shown on page 12.

    Vertical movement joint

    225mm

    225mm

    225mm

    225mm

    900mm

    300mm

    450mm

    450mm

    300mm

    Horizontal movement joint450-900mm Head restraints

    at centres to suit windloading

    Usually225mm tosuit blockcourses

    Usually 225mm tosuit block courses

    225mm

    Vertical movement joint

    450mm

    225mm

    450mm

    Debonded ties

    See typical detail atvertical movement jointon page 12

    Standard spacing for cavity brickwork 900mm x 450mm centres in a staggered pattern (2.5 ties per square metre)

    Typical Layout of Wall Ties Indicating Maximum Spacing

    Length of Tie & EmbedmentWall ties should be of the correct length toensure they are properly embedded in themasonry. The tie should have a minimumembedment of 50mm in each leaf but alsotake site tolerances into account for bothcavity width and centring of the tie. For thisreason we suggest tie lengths which achievean embedment of between 62.5mm and75mm.

    Recommended lengths to suit various cavitywidths are shown for masonry-to-masonry wall ties.

    Recommended Lengths of Masonry /Masonry Wall Ties

    Cavity Width Length of Wall Tie BS 5628-1(mm) (mm) Wall Tie

    50-75 200 HRT4/RT2/ST1

    76-100 225 HRT4/RT2/ST1

    101-125 250 ST1

    126-150 275 SD1

    150 300* ST1

    *These wall ties can be used in 126-150mm cavities ifthey are embedded further into the inner leaf.

    Embedment

    Embedment of Wall Ties

    EmbedmentCavity width

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • BUILDING REGULATIONS PART E:RESISTANCE TO THE PASSAGE OFSOUND

    Part E of the Building Regulations includesrequirements for wall ties. There are twoclassifications: Type A and Type B. Two logosare shown throughout this brochure to indicatethe Ancon and Staifix wall ties that meet theserequirements.

    Type A for Separating or External WallsThese ties must have a measured dynamicstiffness of

  • Ancon ST1200mm for 50-75mm cavities225mm for 76-100mm cavities250mm for 101-125mm cavities300mm for 150mm cavities

    Staifix RT2200mm for 50-75mm cavities225mm for 76-100mm cavities

    7

    U.K. Patent Nos. 2 255 3582 260 3482 260 349

    WALL TIES TO BS 5628-1 FORBRICK-TO-BLOCK CONSTRUCTION

    Ancon ST1 Type 1 Tie(Masonry Heavy Duty)The Ancon ST1 is suitable for cavities from50mm to 150mm and can be used for alltypes of buildings of any height, anywhere inthe British Isles. The section that spans thecavity has a series of holes to provide waterdrips. This allows the same tie to be used ininsulated cavities as well as open cavities.The ST1 has a measured dynamic stiffness of

  • Wall Ties and Restraint Fixings

    8

    TIES FOR THIN-JOINT BLOCKWORKThin-joint construction prevents the use oftraditional cavity wall ties requiring embedmentin 10mm joints and coursing between the innerand outer leaves. The joints in the inner leaf ofblockwork are reduced to 3mm or less by theuse of special thin-joint mortar designed tospeed the rate of construction.

    Staifix-Thor Helical TJ2 Wall TieThe TJ2 wall tie hammers directly into aeratedconcrete blocks, through insulation material,and is built into the bed joints of the outer leafof brickwork. It is ideal for thin-joint blockworkand other applications where the joints in theinner and outer leaves are not aligned. This tiemeets the requirements of the NHBC, BS EN845-1 and BS 5628-1 as a type 2, 3 or 4 walltie depending on the block used and the cavitywidth. Tools are available to simplify installation.

    The helix of the Staifix-Thor Helical range issuperior to other helical fixings. Each rotationinterlocks perfectly down its lengthguaranteeing maximum performance.

    The black Staifix TJ Clip is designed for usewith TJ2 wall ties.

    Embedment Depths

    TJ2 to BS 5628-1

    Block Strength Tie Type to BS 5628-1N/mm2 100mm Cavity 125mm Cavity

    2.8 4 4

    3.5 - 4.0 3 4

    7.0 - 10.5 2 3

    Recommended Lengths

    Cavity Width (mm) Tie Length (mm)

    50 205

    75 230

    100 255

    125 280

    150 305

    TIES FOR TIMBER FRAMES

    Staifix Timber Frame TieThe Staifix Timber Frame Tie is designed to fixbrickwork or blockwork to timber-framedstructures up to 4 storeys in height.

    Available in two lengths to suit 50mm and75mm cavities, the Staifix Timber Frame Tie issupplied complete with an annular ring shanknail. The tie is cranked to simplify correctinstallation and to prevent moisture fromcrossing the cavity.

    The Staifix Timber Frame Tie meets therequirements of DD140: Part 2 as a Type 6 tie and meets the technical requirements of the NHBC.

    Timber Frame Ties should be installed at adensity of 4.4 ties per square metre inbuildings where the basic wind speed doesnot exceed 25m/s (BS 6399-2: 1997 Code ofPractice for Wind Loads). The density shouldbe increased to 7 ties per square metre inmore severe situations.

    85mm 70mm

    Available to suit 50mm and 75mm cavities.

    Density of4.4 ties/m2

    Staifix Timber Frame Tie

    Staifix-Thor Helical TJ2

    Note: For maximum building height and restrictions based on geographical location please refer to page 4.

  • TIES FOR STEEL STUDWORK

    Ancon 25/14 Restraint SystemThe Ancon 25/14 channel system is designedto tie brickwork to steel studding. Self-drillingscrews fix through the channel and theinsulation material, into the steel. Once thechannel is installed, Ancon SD25 wall ties canbe positioned at any point along its length andare built into the bed joints of the outer leaf ofbrickwork.

    The spacing of ties is based on the height ofbuilding and its geographical location. Thetable below should be used in conjunction withthe wind speed map on page 4.

    Ancon recommends that wall ties achieve aminimum embedment of 62.5mm in the outerleaf of brickwork. Applications with a 50mmopen cavity require 100mm long ties.

    25/14 channel features pre-punched holes atclose centres to ensure a fixing position isalways located near the end, even when it iscut on site. It should be fixed to steel studworkat 450mm vertical centres.

    Screws are available to accommodate aninsulation thickness of up to 70mm. Anconrecommends the use of stainless steel fixingscrews. Alternative screws are available.

    The channel has a 16mm opening to easilyaccommodate a drive socket and washer forthe fixing screws.

    This system has been independently tested atCERAM Building Technology and meets thetechnical requirements of the NHBC.

    Vertical Tie Spacing(mm) for Various

    Altitude and Distance Heights of Brickworkfrom the Coast 15m 25m 40m

    Altitude up to 150m and at450 225 225least 50km from coast

    Altitude up to 25m and within450 300 22550km from coast

    9

    Tie Spacing Based on 25/14 Channel at600mm Horizontal Centres with Basic WindSpeed < 25m/s

    Ancon 25/14 Channelwith SD25 Wall Tie

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

    25/14 Channel Profile

    16mm25mm

    14mm

  • Cavity Width (mm) Tie Length (mm)

  • 11

    REFERENCES FOR WALL TIESMany variations are available in addition to thestandard ties. Wall ties for special applicationsmay be specified and ordered with ease byusing a reference letter for the tail, shank andhead of the tie.

    Ancon ties are produced in lengths from150mm for masonry-to-masonry ties, and75mm for masonry-to-concrete ties, inincrements of 25mm. Drips will usually bepositioned 90mm from the outer end of the tie(first reference letter). Masonry-to-masonry tiescan also be supplied with a central drip.Special wall ties with a section wider than20mm referenced S_ _, will have an end withthree holes without the side notches.

    Diameter 80mm

    Head 21

    Shank D

    Tail S

    Ancon SD21wall tie

    Example usingReference System

    TAILMost can be used ateither end of tie

    SHANK

    HEAD

    L _ _

    S _ _

    _ D _

    _ P _

    _ V _

    _ F _

    _ H _

    P _ _

    D _ _

    Y _ _

    M_ _

    W _ _

    T _ _

    Z _ _

    Manufacturedto suit

    25mm

    10mm6x60mm loosedowel

    6x60mm loosedowel

    6x60mm weldeddowel

    L

    L

    10mm

    10mm

    10

    20

    50

    30

    10

    10

    8x30mm slot

    7mm diameter hole

    L

    L

    10mm

    To fit 21/18Omega Channel

    _ _ 25 To fit 25/14_ _ 28 To fit 28/15_ _ 30 To fit 30/20_ _ 36 To fit 36/8 _ _ 38* To fit 38/17

    *Tie will be 25mm wide

    7mm diameter hole

    Tie will be 25mmwide

    105mm

    _ _ V_ _ U without slot

    _ _ B

    _ _ 21

    _ _ X

    _ _ G

    30

    Insulation RetainerThe H75/2 Insulation Retainer is for securingmaterial to concrete, blockwork and brickwork.The 90mm diameter head can hold back up to75mm of insulation. A 10mm diameter hole isrequired in the base material. The projectingend of the retainer is pushed through theinsulation material into the hole and tappedinto position to secure the insulation.

    Insulation Retaining ClipsThe red Staifix Insulation Retaining Clip will fitall the standard ties shown on page 10.

    6.5mmdiameter holes

    15mm15mm

    Debonding SleevesDebonded Ties require 100mm embedment.A 120mm long sleeve will provide anallowance for movement and tolerance, andwill be suitable for most applications. Otherlengths and sizes available tospecial order.

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Wall Ties and Restraint Fixings

    12

    VERTICAL MOVEMENT JOINTSDebonding sleeves are used on plain-endedwall ties, like the Ancon PP21 or PPB, atvertical movement joints. The tie will restrainthe masonry against lateral wind loads but thesleeve will allow the masonry to expand orcontract. Debonding sleeves should beinstalled with a 10mm gap at the end to allowfor expansion of the masonry.

    External Corner with Fully BondedBrickwork

    Note: All spacings are maximums. The type of cavity wall tie and spacing will be determined by the cavity width, heightof brickwork, wind loading and type of building. See page 4 for further information.

    Intermediate Column with VerticalMovement Joints in Blockwork

    Intermediate Column with VerticalMovement Joints in both Brickwork andBlockwork

    Intermediate Column with Vertical Movement Joint in Brickwork and Blockwork

    225mm 225mm

    450mm to 900mm

    Ancon PP21 wall ties with debonding sleeves,at 450mm vertical centres

    Staifix RT2 wall ties at450mm vertical centres inalternate courses to AnconPP21 Wall Ties

    Ancon PP21 wall ties with debondingsleeves, at 450mmvertical centres

    Ancon PP21 wall ties withdebonding sleeves, at450mm vertical centres

    Ancon SD21 wallties at 450mmvertical centres

    Ancon ST1wall tie

    Ancon ST1 wall tie

    Ancon ST1wall tie

    Ancon PP21wall tie withdebondingsleeve

    Ancon PPSwall tie withdebondingsleeve

    Ancon 21/18 Omega channel

    Ancon PPS wall tieswith debondingsleeves, at 450mmvertical centres

    450mm 450mm

    Ancon PPS Wall Tie withDebonding Sleeve

    Cavity Wall with Vertical Movement Joint in Brickwork

    225mm 225mm

    Ancon PPS wall ties with debondingsleeves, at 450mm vertical centres

    Ancon ST1Wall Tie

    10mmGap

    Debonding sleeves should be pulled back 10mm to allow expansionas well as contraction of brickwork

  • Cavity Width (mm) Length of Wall Tie (mm) Frame Cramp/Channel Tie

    20-44 100 SPB/SP2145-69 125 SDB/SD2170-94 150 SDB/SD2195-119 175 SDB SD21120-144 200 SDB/SD21145-169 225 SDB/SD21

    13

    ANCON FRAME CRAMPSFrame cramps can be fixed to concrete,steelwork or masonry and have a single 7mmdiameter hole or an 8mm x 30mm vertical slot.Ancon M6 Single Expansion bolts arerecommended for fixing to concrete, setscrews or self-drilling screws for steelwork,and suitable plugs and screws for fixing tomasonry. Large washers must be used with allSDVs and similar ties with a slot. Other fixingsmay also be suitable.

    Poor substrates will limit the capacity of framecramps and site testing may be advisable insome cases. The performance will also bedetermined by the position of the fixing. SDVties fixed to steelwork or concrete at thelowest point of the slot will have a safe workingload of approximately 1kN. The capacity willreduce as the fixing is moved further awayfrom the bend and greater movement must beexpected than with other types of wall tie.

    Ancon isolation sleeves and pads are suppliedblank for use with self-drilling screws to isolatestainless steel frame cramps from mild steel.

    Ancon HiT - Hammer-in TieThe Ancon HiT fixes masonry cladding toconcrete. It can reduce the variety of tielengths required on site and speed the rate ofconstruction. The HiT is available in a standardlength of 310mm that is bent on site with aspecial installation tool to suit all cavities up to150mm. Unlike conventional frame cramps itdoes not require a mechanical fixing, but ishammered into a plug. The Ancon HiT meetsthe requirements of BS 5628-1 as a Type 2 tie.A neoprene 'O' ring must be installed on thetie to prevent moisture crossing the cavity.

    PRE-FIXING AIDSThe practice of pre-fixing frame cramps inadvance of masonry can accelerate the speedof construction and provides an opportunity tocheck that wall restraints have been locatedcorrectly and securely fixed.

    Ancon Gauge Tape (Pre-fix Patent 2 256 223)Gauge Tape illustrates the standard 225mmbrick/block gauge and the fixing position of framecramps. It is applied directly to the structuralframe (steel, concrete, timber or masonry) tofacilitate the pre-fixing of frame cramps and tomaintain accurate masonry coursing.

    Ancon ISO-TW WasherThe ISO-TW washer enables Ancon slot-ended frame cramps to be vertically adjustedwithin the 30mm range of the slot to suit theexact location of mortar joints without affectingthe integrity of the fixing. In addition, thiswasher prevents bi-metallic corrosion byseparating the frame cramp from the structuralframe and fixing screw.

    Recommended Safe Working Loads for 20 x 2.5mm Section Frame Cramps

    SDV Wall Tie

    90mm

    1000900800700600500400300200100

    0SDV

    Fixing atbottom of slot

    N

    SDB SDVFixing in

    centre of slot

    SDVFixing at

    top of slot

    90mm 90mm

    Length Length

    EmbedmentEmbedment

    SDB Wall Tie Fixed to Steelwith Self-Drilling Screw

    Isolation Sleeve

    Isolation PadSD21 Wall Tie Fixed into 21/18Omega Channel

    Recommended Lengths of Frame Cramps and Channel Ties

    SDB Wall Tie

    90mm

    Ancon Hammer-in Tie (310mm) Ancon ISO-TW and Gauge Tape

    Note: Frame cramps should have a minimum embedment of 50mm in the outer leaf. Taking site tolerances into account,Ancon suggests tie lengths which achieve a greater embedment.

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Fixing Method Omega 21/18 25/14 28/15 30/20 38/17 36/8

    Cast-in

    Surface Fixed

    SWL (tension) 25/14 28/15 38/17 36/8

    0.5kN 337 525 650 300

    1.0kN - 400 525 -

    Wall Ties and Restraint Fixings

    14

    Fixing of Channel

    Maximum Centres for Surface-Fixing

    Ancon Fastrack Channels 100mm long with SD28 Tie

    Fastrack used with DD28 Tie for Stonework

    Fastrack used with SD28 Tie for Brickwork

    ANCON FASTRACKBuilding one leaf of the cavity wall in advanceof the other is often beneficial but can createproblems with coursing. Buildings whichincorporate imperial or continental bricks andstandard metric blocks present even greaterdifficulties.

    Ancon Fastrack Channel is built into the innerleaf of blockwork ready to take an AnconSD28 or similar tie for the outer leaf. Thismethod of construction avoids the dangers of projecting ties.

    Ancon Fastrack Channels and Ties can besupplied in different lengths and can also beused for tying stonework to blockwork if DD28or similar Ancon Ties are used.

    Ancon Fastrack Channels and Ties sustainloads which exceed the requirements for aType 2 tie to BS 5628-1. This system can alsobe manufactured in a 36/8 channel profile thataccepts wall ties referenced _ _ 36.

    Ancon 25/14, 28/15, 30/20, 38/17, and 36/8 ChannelsAncon wall ties can also be used with our25/14, 28/15, 30/20, 38/17 and 36/8channels. 30/20 Channel is supplied withanchors for casting into concrete. 25/14 and36/8 Channels are supplied plain-backed forsurface fixing. 28/15 and 38/17 Channels areavailable with or without anchors for casting inor surface fixing. Ties for 38/17 channel will be25mm wide to accommodate the wideropening; all other channel ties will be 20mmwide. Wall ties used with Ancon 28/15, 30/20,38/17 channel will provide safe working shearand tensile loads of up to 1.0kN, while wall tiesused with 25/14 and 36/8 channels will provideup to 0.5kN. Maximum safe working loads ofsurface-fixed channels will be subject tosuitable fixings, and appropriate fixing centres.

    Available Lengths of Ancon 21/18 Omega Channel100, 3000mm U.K Patent No. 2 249 110

    Ancon 21/18 Omega Channel with AnconSD21 Tie

    ANCON CHANNELSAncon 21/18 Omega ChannelAncon 21/18 Omega Channel is a highperformance, self-anchoring, cast-in channelslot suitable for use with our wall ties toprovide the necessary restraint to the outer leafof masonry. The section is only 18mm deepand can be used where there is reduced coverto reinforcement. Available in 100mm and3000mm lengths, Ancon 21/18 OmegaChannel is filled with polystyrene to helpprevent the ingress of concrete. Nail holes aidthe fixing of the slot to timber formwork. Wallties used with Ancon 21/18 Omega Channelwill provide safe working shear and tensileloads of 1.5kN.

  • Staifix Universal Wall Starter SystemThis system includes all necessary fixings tojoin a single skin of masonry, 2400mm high, to an existing wall. Each pack includes 2 fixingstrips, 5 plugs, 5 washers, 5 screws and 10 wall ties. Suitable for wall widths from 60mmto 250mm and masonry up to 8 metres inheight, this system will resist a wind load of upto 4.5kN over a height of 2400mm. Wall Tiesslide within the fixing strip to course with thebed joints of any masonry unit. This UniversalWall Starter System meets the technicalrequirements of the NHBC.

    Staifix Cavity Starter TieThis tie simplifies the building of an inner leaf of blockwork within an existing structure. It isideal for barn conversions.

    WALL STARTER SYSTEMS36/8 Wall Extension SystemThe 36/8 Wall Extension System can be suppliedwith either SP36 ties or, where some longitudinalmovement must be accommodated at thejoint, PP36 ties complete with debondingsleeves. The channel can be supplied inlengths of up to 3.4 metres with each lengthhaving a series of holes to allow fixing to theexisting wall. The system is available as a kitcomprising a length of 36/8 channel 2400mmlong, six ties and five plugs and screws.

    Staifix Starter TieThis tie is quick and simple to install. It issuitable for use in brickwork and blockwork ofup to 3 storeys or 8 metres in height andmeets the technical requirements of the NHBC.

    Supplied complete with an 8mm nylon wallplug, the Starter Tie is fixed into the existingwall at an angle of 30 to the horizontal andbent into the bed joints of the new brickwork.Ties should be fixed at 225mm vertical centresand be central to each leaf of the new wall.

    Staifix Frame TieThe Staifix Frame Tie is used to join timberdoor and window frames directly to brickwork.The Frame Tie is designed for use on buildingsof up to 15 metres in height, and meets thetechnical requirements of the NHBC. The tiesare screwed horizontally into the frame,surrounded by mortar and built into the bedjoints of the new brickwork.

    The vertical spacing of frame ties depends onthe application. Please contact Ancon or yourlocal Staifix stockist for more information.

    15

    36/8 Wall Extension System Staifix Universal Wall Starter System

    Existing Outer LeafNew Inner Leaf

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Wall Ties and Restraint Fixings

    16

    Installation of Staifix TE-ITC2 Wall Ties

    Embedment

    Insulation retaining clipBubble foil insulation

    Embedment

    Multiple drips

    Cavity width

    Staifix TE-ITC2Patents applied for

    Staifix TE-ITB4*Lengths 185, 200mmPatents applied for

    *

    ANCON TWO-PART TIECavities exceeding 150mm are sometimesrequired. This necessitates longer ties whichcan be difficult to balance and keep horizontalwhen built into the inner leaf. The Ancon Two-Part Tie has one section built into theblockwork; the other section is then fixed asthe outer leaf is built. The inner tie is usuallymanufactured in lengths of 170mm. Variationin the cavity width is accommodated by thelength of the outer tie. Insulation RetainingClips can be supplied to fit the inner section.

    Ancon Two-Part Ties sustain loads whichexceed the requirements for a Type 2 tie toBS 5628-1 for cavities up to 300mm. Anembedment of 75mm is required at each end.

    U.K. Patent No.2 265 920

    Outer Section

    170mm

    Length to suitapplication

    Inner Section

    TIES FOR BUBBLE FOIL INSULATIONA range of ties are manufactured under licensefrom Thermal Economics Ltd for use withBubble Foil Insulation. These ties have beendesigned to BS 5628-1 and are available as Type 2 and Type 4 ties. ITB referenced tiesenable the insulation material to be installedflush to the blockwork. ITC referenced tiesposition the insulation 25mm away from theblock. These ties meet the technicalrequirements of the NHBC.

    BS 5628-1 Length Cavity RangeReference Type (mm) (mm)

    TE-ITB4-185 4 185 50-60

    TE-ITB4-200 4 200 60-75

    TE-ITC4-200 4 200 60-75

    TE-ITB2-200 2 200 60-75

    TE-ITC2-200 2 200 60-75

    TE-ITC2-225 2 225 85-100

    Note: Refer to page 4 for more information on Type 4and Type 2 ties.

  • 17

    ANCON BRICLOKTraditional methods of fixing masonry tosteelwork, using frame cramps which are boltedto the column, can be difficult, time consumingand expensive. This slows down the laying ofbricks, wasting valuable production time on site.

    Ancon Briclok

    Lengths 150, 200mm

    Ancon Briclok offers simplicity by eliminatingthe need for specialist tools and complexoperations. The tie is positioned with the mostsuitable notch around the column flange withno less than 10mm engagement. The tie mustnot be forced onto the flange.

    Bi-metallic contact in damp conditions maycause the column to suffer some slight surfacecorrosion. This will not affect the structuralperformance of either the Briclok or thecolumn. Mild steel columns will usually beprotected. However, bitumen paint, applied bybrush at the contact area will help alleviatecorrosion of the column. Briclok Ties restrainthe inner leaf and sustain loads which exceedthe requirements for a Type 2 tie to BS 5628-1.

    ANCON COLUMN TIESAncon Column Ties, which clamp to theflanges of structural steel columns, can beused across the cavity to the brickwork orback into the blockwork.

    These are available in different lengths and willaccommodate flanges from 6mm to 25mm.

    Intermediate Column withMovement Joint in Brickworkand Blockwork

    Ancon Briclok at450mm vertical centres

    60mm min.

    25mm min.

    450mm 450mm

    Staifix RT2 Wall Ties at 900mmhorizontal and 450mm verticalcentres in a staggered pattern

    Ancon PPS Wall Ties withDebonding Sleeves, at450mm vertical centres

    Staifix RT2 Wall Ties at 450mmcentres in alternate courses toAncon Briclok

    Ancon Briclok at 450mm vertical centres

    225mm 225mm

    25mm

    185mm75mm

    71mm

    Intermediate Column withMovement Joint in Blockwork

    19mm

    15.5mm22mm

    18mm18mm

    13mm30mm

    22.5mm

    150, 200mm

    Ancon Column Tie Fixed to Flange

    Ancon SRB Wall Ties fixedto column flange at 450mmvertical centres

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

    ANCON SLIP-BRICK TIESAncon Slip-Brick Ties are bolted directly toblockwork or concrete to give both supportand restraint to thin slip brick facings. Inaddition to the standard three brick version,slip brick ties can be manufactured in othermultiples on request.

    NON-DRILL FIXINGS FORSTEELWORKAncon manufactures a comprehensiverange of non-drill masonry-to-steel fixingsolutions designed to address theindustrys safety concerns with shot-firingand exposure to Hand Arm Vibration.These innovative solutions provide simple,safe and economical means of connectingto steelwork. The range includes internalcolumn ties, head restraints andalternatives to frame cramps. ContactAncons sales or technical services teamsfor more information.

  • Wall Ties and Restraint Fixings

    18

    Ancon YDB Ties Fixed to Blockwork

    RESTRAINTS FOR STONE CLADDINGReference should be made to BS 8298: 1994Design and installation of natural stonecladding, when selecting ties for restrainingstone cladding. Restraints should be designedto resist wind loads and any imposed loadsfrom, for example, window cleaning equipment.

    Each stone will normally be restrained in fourplaces, two at the top and two at the bottom.These are usually situated in the horizontaljoints. The restraints should be located in pre-formed mortises or holes positioned in thecentre of the thickness of the stone panel, andlocated at 1/4 points for half bonded stonesand 1/5 points for stack bonded stones.Restraints should be kept at least 75mm fromany corner with the peripheral distances betweenany two restraints not exceeding 1200mm.

    The embedment of restraint dowels and lips into the stone should be at least 20mm. To achieve this lipped ties, (LPBs) have a25mm downstand and dowelled ties (DPBsand YPBs) have 60mm long dowels.

    Buchanan Galleries, Glasgow

  • 19

    Two Ancon YPB Ties Restraining Coping Stone

    More than 3.7m above Soffits - including Sills, copings andground - including facias inlined soffits supported reveals

    Type of Stone T (mm) t (mm) T (mm) t (mm) T (mm) t (mm)

    Granite, slate, white 40 15 40 15 30 12marble, quartzites

    Hard limestone, 40 15 40 15 30 12travertines

    Limestone, 75 30* 75 30* 50 20*sandstone

    * t = T/2 if stone thickness (T) is greater than 75mm

    Minimum Stone Thickness T and Minimum Dimension Behind Restraint t

    20mm

    20mm

    T/2

    T/2

    TW

    1200mm max.20mm

    75mm

    t

    t

    1200

    mm

    max

    .

    W/5 Stack bonded stone

    W/4 Half bonded stone

    Recommended Restraint Positions in Stone Cladding

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Ancon LD21 Ties Fixed into 21/18 Omega Channel, Restraining Top of Stone

    20

    Section of TiesMinimum sections for restraints for variousthicknesses of stone are shown in the tablebelow. Restraints for large stones and for usewhere cavities are in excess of 100mm mayrequire special attention. They may need amuch bigger section than 20 x 2.5mm; tiesformed from 20 x 3mm, 25 x 3mm, 30 x 3mmand 30 x 4mm are frequently used forrestraining stone cladding.

    Drip PositionDue to the wide varieties of design cavity andstone and insulation thickness it is not possibleto standardise the position of any requireddrip. If a drip is required (e.g. YDB) pleasespecify the position clearly, indicating fromwhich end of the tie the measurement is taken.

    Approved Document EAncon flat ties have a measured dynamicstiffness of

  • Facing Cavity Safe WorkingThickness Min. Max. Hole Size Load*

    Reference (mm) (mm) (mm) (mm) (N)

    2000/A20 25 70 8 x 90 600

    25 22 67 8 x 90 600

    2000/B30 30 75 8 x 90 600

    40 25 70 8 x 90 600

    20 60 105 8 x 90 600

    2000 - 7525 57 102 8 x 90 600

    30 55 100 8 x 90 600

    40 50 95 8 x 90 600

    Other sizes available to order. *In grade 30N/mm2 concrete

    Ancon 150The Ancon 150 is a grout-in masonry tie forthe restraint of 20 to 30mm thin facings, andsuitable for cavities up to 60mm wide. The 12x 2mm corrugated body provides optimumbond in a 12 x 90mm hole. The 50 x 3mmdowel is supplied loose.

    21

    Facing thickness

    Ancon 2000Ancon 2000 restraint fixings are a simple andsecure method of fixing thin facing slabs. Thefixing is quickly and easily installed with thesmall diameter hole giving lower drilling costsand minimum disturbance to the structure.Vertical and lateral adjustment is provided bythe slotted holes in the fixing clip.

    Ancon 2000

    Push-Off Bolt

    Cavity

    Stone Insulation Inner Leaf

    Ancon Push-Off BoltThe Push-Off Bolt provides the centre of stonepanels with additional resistance to the effectsof impact loads, blast loads and positive windpressure. The Bolt features a mechanicalexpander at one end which fixes securely intothe inner leaf. The external stone panel ispositioned with its inner face flush to the boltsneoprene pad, which cushions the surface andprevents any rattling. The Push-Off Bolt issupplied in a variety of lengths to suit cavitiesfrom 100 to 200mm.

    Ancon 2000 Thin Facing Restraints

    Ancon 150

    Museum of Scotland, Edinburgh

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Wall Ties and Restraint Fixings

    22

    Ancon FHR - Head RestraintThe Ancon FHR Head Restraint is used forrestraining the top of internal walls or theinternal leaf of a cavity wall. The two anglesclamp the top of the wall and have 9mmdiameter holes to suit M8 bolts. They aresupplied with two holes in the longer angle toallow the restraint to fit 100mm and 140mmblockwork. Each restraint can resist a serviceload of 1kN.

    ANCON HEAD RESTRAINTS Ancon Head Restraints provide the necessaryrestraint to the top of masonry walls. Theyallow for vertical movement to accommodateshrinkage or thermal movement of the wall orstructural frame, while restraining wind loads.

    Ancon IHR - Internal Head RestraintThe Ancon IHR is used for restraining the topof internal walls or the top of the inner leaf of acavity wall. The opening at the front of thechannel stem is sealed to prevent mortaringress and to ensure that vertical movementcan take place between the blockwork and thestructure. The base of the stem must be builtwithin a bed joint with the centre of the stemno closer than 50mm from the edge of theblock. The vertical joint should be filled withmortar each side of the stem. The maximumjoint between the top of the blockwork and theunderside of the frame should not be greaterthan 25mm.

    The sliding tie can be provided with either ahole or slot to suit M8 bolts, or with a notchend to fix directly into a 38/17 or 30/20 cast-inchannel. The standard Ancon IHR will suit a215mm high block and can resist a load of1.5kN. Other sizes between 150 - 250mm are available.

    Ancon IHR - B Bolted to Concrete,Restraining Top of Inner Block Wall

    To suitBlockwork

    Ancon IHR - C Restraining Top of Inner Block Wall to 38/17 Channel Cast into Concrete

    Ancon FHRHead Restraint

    Ancon FHR Head Restraint Fixed toUnderside of Floor Slab, Restraining Headof Inner Leaf of Cavity Wall

    Ancon IHR - Cto suit Cast-inChannel

    IHR - C 38to suit 38/17

    IHR - C 30to suit 30/20

    Ancon IHR - Vwith Slot

    Ancon IHR - Bwith Hole

    75mm

    25mmmax.

    25mmmax.

    50mmmin.

    215mm

  • 110m

    m

    38mm45mm

    25mm

    15mm 15mm130mm 130mm

    95mm50mm

    15mm

    160mm

    160mm

    160mm

    38mm

    SAH - F SAH - T SAH - U SAH - UF

    340mmmin. 600mmmax.

    340mmmin. 600mmmax.

    340mmmin. 600mmmax.

    340mmmin.

    600mmmax.

    340mmmin. 600mmmax.

    340mmmin.

    600mmmax. 340mm

    min. 600mmmax.

    SAH - UO

    SIS

    SPI

    SAH - UT SAH - UC

    off-setto suit

    Length and slotposition to suitapplication

    Length to suitapplication

    23

    Ancon Wall Ties to suit SAH Sliding Anchors

    Head dimensions and hole positions are variable.

    SAH - F SAH - UO withExtended Head

    Ancon SAH - Sliding AnchorsAncon SAH Sliding Anchors have stemswhich fit within the cavity and accept tiesthat slide to accommodate vertical movement.Available with seven different head options asstandard, they are supplied with one-way ortwo-way ties with safety ends.

    The standard fixing hole is 12mm diameter tosuit Ancon M10 Single Expansion Bolts orM10 T Head Bolts to fit Ancon 28/15 Channel.Ancon SAH Sliding Anchors have 25 x 5mmstems and a maximum service capacity of 1kNper stem when the upper tie is within 75mm ofthe fixing. Ties should be spaced at aminimum of 150mm and at least two tiesshould be used per stem.

    These drawings are examples only. All slidinganchors are manufactured to suit individualrequirements.

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Compressive FailureStrength Load

    Base Material (N/mm2) (kN)

    Hard Brick 27.5 5.1

    Soft Brick 17.0 3.7

    Portland Stone 20.0 5.2

    Concrete Block 7.0 1.8

    Note: Test results are an average of 20 No ties.

    Cavity Widths Tie Lengths Drill Diameter Drill Depths(mm) (mm) (mm) (mm)

    50-70 195 10.5 60-70

    71-95 220 10.5 60-70

    96-125 250 10.5 60-70

    126-175* 300 10.5 60-70

    *or where greater embedment is required.Note: For cavities over 100mm horizontal spacing should be reduced to 450mm.

    Wall Ties and Restraint Fixings

    24

    SpacingNo British Standard has yet been defined forthe spacing of remedial wall ties. However,accepted practice is to follow BS 5628 that is900mm horizontally and 450mm vertically in astaggered pattern with 300mm vertical centresaround openings within 225mm of the opening.

    Installation of Remedial Wall TiesMechanical ties are easily installed by meansof two Setting Tools. The tie is fitted to thesetting tool for the inner leaf and inserted intoa pre-drilled hole in the wall. The required drilldepth for each tie is shown in the table below.The inner shell is expanded by turning thehandle until the correct torque is reached. The tool for the outer leaf, with a hexagonal-shaped end, is then fitted and adjusted toexpand the outer shell. The process is quickand simple and ensures that each tie iscorrectly installed.

    Ancon 63 Setting Tools

    Setting Tool - Outer

    Setting Tool - Inner

    REMEDIAL WALL TIES

    Corrosion of Cavity Wall TiesWall ties are an essential element in thestability of masonry panels. Prior to 1978, wallties were usually manufactured from galvanisedmild steel. These ties were expected to last thelifetime of the building, but for many years ithas been recognised that some of these wallties have corroded after only 15 or 20 years.

    When these ties corrode, they can expand to seven times their original thickness. This causes the brickwork to crack at themortar joints and can result in major damageand sometimes the collapse of walls.

    It is crucial that the problem is identified asquickly as possible and the correct remedialaction undertaken.

    Ancon 63 RangeThis is the original remedial wall tie which hasbeen used in various forms since 1972. The Ancon 63 range has been continuallyimproved to keep pace with changingrequirements. These ties are easy to install anda secure fixing is achieved with a minimumamount of disturbance.

    Highly corrosion-resistant materials are usedthroughout the 63 range. The grade 304stainless steel body of the MM 63 hasexpansion shells at both ends for installationinto a 10.5mm diameter hole. A neoprene ringprevents moisture travelling past the centre ofthe tie.

    Test ResultsThe '63 ties have been tested independently ina variety of materials using the standard '63tie, a summary of results is given in the table.The failure loads noted in the table areobtained from standard tests in brick coupletsand provide indicative values of tieperformance. The couplet test producesresults of a conservative nature compared toactual wall tests. Due to the variability ofmaterials, it is often prudent to undertake apull-out test on site, to verify the selection ofan appropriate tie.

    Drill Depths

    Failure Loads (Pull-Out) for the Ancon 63 Range

    Compressive FailureStrength Load

    Base Material (N/mm2) (kN)

    Dense Concrete Block 7.0 - 10.5 5.78

    Lightweight Concrete Block 2.8 - 3.5 2.87

    Mortar Bed Joint, 1:1:6 Type (iii) BS 5628 - 5.37

    Failure Loads (Pull-Out) for Staifix R/R

  • Temperature (C) in Substrate Setting Time

    - 5 360 mins

    0 180 mins

    + 5 90 mins

    + 20 45 mins

    + 30 30 mins

    + 40 25 mins

    25

    Ancon 63 Mechanical/MechanicalUsed when tying together two leaves of solidmaterials, this tie has mechanical expanders ateach end. Requires 10.5mm holes.

    Ancon 63 Resin/MechanicalFor use when the material in the inner leaf isperforated, of low-density or a friable material.A resin fixing may be used to eliminate anyimposed stress. Requires 10.5mm or 11mmholes.

    Staifix Resin/ResinUsed where mechanical expanders areunusable. Normally inserted into a 10mm hole,but if test facilities are required, a 12mm holemust be used.

    A plastic sieve can be used to retain resin and is particularly useful in perforated brick orhollow blockwork. A 12mm hole is required tofit the sieve.

    Stairib BarStainless steel ribbed bar, resin-grouted intothe inner and outer leaves.

    Ancon AC 31Used where bricks are removed then replaced in the outer leaf. The wavy end is resin-bondedinto the inner leaf in a 10mm hole. The triangularend sits in the bed joint. Ancon AC 31 can besupplied with a drip or a neoprene ring.

    Ancon AC 31CSimilar to the AC 31 but cranked by 25mm toaid fixing to the inner leaf.

    Cameron T 47Used for the repair of mass brickwork with anunbonded brick faade, sometimes built fromsnapped headers. The T end is built into thebed joint and perpend, and hidden when thebrickwork is repointed.

    Fischer FIS P 380 C ResinThis styrene-free injection resin is quick settingand suitable for a wide range of applications.The two components are safely mixedtogether inside the nozzle. Automatic mixingensures an accurate blending of thecomponents and, being mixed only asrequired, the minimum of wastage. Resin gunsand additional mixing nozzles are available.

    Ancon MM 63195mm for 50-70mm cavities220mm for 71-95mm cavities250mm for 96-125mm cavities300mm for 126-175mm cavities

    Ancon RM 63195mm for 50-70mm cavities220mm for 71-95mm cavities250mm for 96-125mm cavities300mm for 126-175mm cavities

    Staifix R/R180mm for 40-60mm cavities200mm for 61-80mm cavities220mm for 81-100mm cavities

    Stairib BarLength to order6, 8mm dia.

    Ancon AC 31Lengths 175, 200 ,225mm

    Ancon AC 31CLengths 175, 200,225mm

    Cameron T 47Lengths 200, 250,300mm 4.7mm dia.

    Setting Times for FIS P

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • TMR Dimensions (mm)

    Standard Length 3050

    Standard Widths 50 , 100 , 150Longitudinal Wires 4 diameter

    Cross Wires 3.75 diameter

    Cross Wire Pitch 400

    Welding Resistance

    Wall Ties and Restraint Fixings

    26

    ANCON MASONRY REINFORCEMENTAncon Masonry Reinforcement offers a low-cost solution to the corrosion problemsassociated with conventional reinforcedmasonry. The use of stainless steel minimisesthe need for close control of mortar cover andensures continuing structural performancethroughout the life of the building or structure.

    The lightweight Ancon ladder and lattice typereinforcements are highly ductile and readilycut and shaped on site. This material is totallycompatible with our other stainless steelmaterials and provides many design solutionswhere structural composite action is required.Ancon Masonry Reinforcement conforms toBS 5628: Part 2: 2000.

    60mm

    100mm

    150mm

    50mm

    100mm

    150mm

    225mm

    225mm60mm

    60mm

    SMR 60

    SMR 100

    SMR 150

    TMR 50

    TMR100

    TMR 150

    SMR 225

    SMR 225C

    Ancon SMR 60Used on Single Leaf Wall

    Ancon SMR 225CUsed on Cavity Wall

    Ancon TMR 50Used on Single Leaf Wall

    Mesh RollStainless steel reinforcement mesh can besupplied in 20m coils. Standard widths include61mm, 112mm, 178mm and 228mm.

    TMR SMR

    Characteristic Strength 500N/mm2 850N/mm2of Longitudinal Wires

    Mechanical Properties

    SMR Dimensions (mm)

    Standard Length 2400

    Standard Widths 60 , 100 , 150 , 225Nominal Max. Thickness 5at Weld Overlap

    Longitudinal Wires 3.3 diameter

    Cross Wires 2.3 diameter(3.3 dia. for SMR 225C)

    Cross Wire Spacing 500

    Nominal Overhang 4

    Welding Resistance

  • 27

    OTHER ANCON PRODUCTS

    Masonry Support SystemsMasonry cladding on concrete or steel framesis normally supported from stainless steelsupport systems. AnconOptima and AnconMDC Systems create a continuous angle tosupport the outer leaf of masonry. AnconIndividual Brackets support masonry featuressuch as curves and arches. A full designservice is available to specifiers and users ofAncon systems.

    Windposts and Parapet PostsLarge panels of masonry or panels withopenings can often be difficult to justifystructurally. Ancon Windposts are designed toprovide additional lateral support for panels ofbrickwork. The range is manufactured fromstainless steel and includes Windposts whichcan be installed into the inner leaf of blockworkand Windposts for installation into the cavity,which leave the blockwork undisturbed.Parapet Posts are used as vertical support forbrickwork in either parapet or spandrel panels.

    Channel and Bolt FixingsAncon offers a wide range of channels andbolts in order to fix stainless steel masonrysupport, restraints and windposts to structuralframes. Cast-in channels and expansion boltsare used for fixing to the edges of concretefloors and beams. A range of stainless steelset screws and self-drilling screws aredesigned to fix to steel frames.

    Tension SystemsTie bars are increasingly being used instructures and buildings as an architectural aswell as a structural element. Ancon 500Tension Systems comprise a range ofcomponents which can be supplied in carbonsteel or stainless steel in a variety of sizes andfinishes. They have a high load capacity andlook particularly impressive when used withlarge areas of glazing or curved timber trusses.

    Shear Load ConnectorsAncon DSD and ESD Shear Load Connectorsare used to transfer shear across expansionand contraction joints in concrete. They aremore effective at transferring load and allowingmovement to take place than standard dowels,and can be used to eliminate double columnsat structural movement joints in buildings.

    APPLICATIONS

    Mixed-Use DevelopmentTottenham Court Road, London, UK

    Residential DevelopmentBreakfast Point, Sydney, Australia

    Residential DevelopmentLondon Docklands, UK

    Commercial DevelopmentBrindley Place, Birmingham, UK

    TempleNew York State, USA

    Tel: + 44 (0) 114 275 5224 Web: www.ancon.co.uk

  • Ancon Building Products 2003

    BS EN ISO 9001 : 2000FM12226

    The construction applications and details provided in this literatureare indicative only. In every case, project working details should beentrusted to appropriately qualified and experienced persons.

    Whilst every care has been exercised in the preparation of thisdocument to ensure that any advice, recommendations orinformation is accurate, no liability or responsibility of any kind isaccepted in respect of Ancon Building Products.

    With a policy of continuous product development Ancon BuildingProducts reserves the right to modify product design andspecification without due notice.

    These products are available from:

    Ancon Building ProductsPresident Way, President ParkSheffield S4 7URUnited KingdomTel: +44 (0) 114 275 5224Fax: +44 (0) 114 276 8543Email: [email protected]: www.ancon.co.uk

    Ancon (Middle East) FZEPO Box 17225Jebel AliDubaiUnited Arab EmiratesTel: +971 (0) 4 883 4346Fax: +971 (0) 4 883 4347Email: [email protected]

    Ancon Building Products114 Kurrajong AvenueMount DruittSydneyNSW 2770AustraliaTel: +61 (0) 2 9675 1000Fax: +61 (0) 2 9675 3390Email: [email protected]: www.anconbp.com.au

    Ancon (Schweiz) AGGewerbezone Widalmi 103216 Ried bei KerzersSwitzerlandTel: +41 (0) 31 750 3030Fax: +41 (0) 31 750 3033 Email: [email protected]: www.ancon.ch

    Ancon Building Products GesmbHGerspergasse 9/3 Top 1A-1210 ViennaAustriaTel: +43 (0) 1 259 58 62-0Fax: +43 (0) 1 259 58 62-40Email: [email protected]: www.ancon.at

    Ancon GmbHBartholomusstrasse 2690489 NurembergGermanyTel: +49 (0) 911 955 1234 0Fax: +49 (0) 911 955 1234 9Email: [email protected]: www.anconbp.de

    CAVITY WALL TIE SELECTIONBS 5628-1: 2005 Code of Practice for theDD140: Part 2: 1987: RecommendationsBS EN 845-1: 2003 Specification forMinimum Requirements for Wall Ties to BS 5628-1: 2005 and DD140-2Selection of Wall Ties to BS 5628-1: 2005Density & Positioning of TiesTypical Layout of Wall Ties Indicating Maximum SpacingLength of Tie & EmbedmentRecommended Lengths of Masonry /INSTALLATION GUIDANCEBUILDING REGULATIONS PART E:WALL TIES TO BS 5628-1 FORAncon ST1 Type 1 TieStaifix RT2 Type 2 TieStaifix HRT4 Type 4 TieTIES FOR THIN-JOINT BLOCKWORKTIES FOR TIMBER FRAMESTIES FOR STEEL STUDWORKAncon 25/14 Restraint SystemSTANDARD WALL TIESREFERENCES FOR WALL TIESVERTICAL MOVEMENT JOINTSANCON FRAME CRAMPSAncon HiT - Hammer-in TiePRE-FIXING AIDSAncon Gauge Tape (Pre-fix Patent 2 256 223)Ancon ISO-TW WasherANCON CHANNELSAncon 21/18 Omega ChannelAncon 25/14, 28/15, 30/20, 38/17, andANCON FASTRACKWALL STARTER SYSTEMS36/8 Wall Extension SystemStaifix Universal Wall Starter SystemStaifix Starter TieStaifix Frame TieStaifix Cavity Starter TieANCON TWO-PART TIETIES FOR BUBBLE FOIL INSULATIONANCON BRICLOKANCON COLUMN TIESNON-DRILL FIXINGS FORANCON SLIP-BRICK TIESRESTRAINTS FOR STONE CLADDINGMinimum Stone Thickness T and Minimum Dimension Behind Restraint tSection of TiesDrip PositionApproved Document EDowelsWire TiesAncon 150Ancon Push-Off BoltAncon 2000ANCON HEAD RESTRAINTSAncon IHR - Internal Head RestraintAncon FHR - Head RestraintAncon SAH - Sliding AnchorsREMEDIAL WALL TIESANCON MASONRY REINFORCEMENTAPPLICATIONSOTHER ANCON PRODUCTS