analytical report 6 · page 5 of 15 6/16/2016 1 2 3 4 5 6 7 8 9 10 11 12 procedure hdp-pr-qa-006,...
TRANSCRIPT
ANALYTICAL REPORTTestAmerica Laboratories, Inc.TestAmerica St. Louis13715 Rider Trail NorthEarth City, MO 63045Tel: (314)298-8566
TestAmerica Job ID: 160-17741-1Client Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
For:Westinghouse Electric Company LLC3300 State Road PFestus, Missouri 63028
Attn: Mr. Martin Swanson
Authorized for release by:6/16/2016 4:33:49 PMRhonda Ridenhower, Manager of Project [email protected] forIvan Vania, Project Manager II(314)[email protected]
This report has been electronically signed and authorized by the signatory. Electronic signature isintended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
123456789
101112
Table of ContentsClient: Westinghouse Electric Company LLCProject/Site: HDP RFP-CBA-022 (7 DAY TAT)
TestAmerica Job ID: 160-17741-1
Page 2 of 15TestAmerica St. Louis
6/16/2016
Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Case Narrative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Chain of Custody . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Receipt Checklists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Definitions/Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Method Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Sample Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Client Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10QC Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11QC Association Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Tracer Carrier Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
123456789
101112
Case NarrativeClient: Westinghouse Electric Company LLC TestAmerica Job ID: 160-17741-1Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Job ID: 160-17741-1
Laboratory: TestAmerica St. Louis
Narrative
CASE NARRATIVE
Client: Westinghouse Electric Company LLC
Project: HDP RFP-CBA-022 (7 DAY TAT)
Report Number: 160-17741-1
With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples,
the reporting limits are adjusted relative to the dilution required.
TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmerica’s operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data
have been found to be compliant with laboratory protocols unless otherwise noted below.
The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %
solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the
client.”
This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.
RECEIPT
The sample was received on 6/9/2016 11:30 AM; the sample arrived in good condition, properly preserved and, where required, on ice. The temperature of the cooler at receipt was 3.4º C.
TECHNETIUM-99 (ICPMS)Sample L09-02-06-P-E-S-00 (160-17741-1) was analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A.
The samples were prepared on 06/13/2016 and analyzed on 06/14/2016.
No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
PERCENT SOLIDS
Sample L09-02-06-P-E-S-00 (160-17741-1) was analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 06/10/2016.
Batch 255888:
TestAmerica St. LouisPage 3 of 15 6/16/2016
123456789
101112
Case NarrativeClient: Westinghouse Electric Company LLC TestAmerica Job ID: 160-17741-1Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Job ID: 160-17741-1 (Continued)
Laboratory: TestAmerica St. Louis (Continued)
The following samples could not be thoroughly homogenized before sub-sampling was performed due to sample matrix:
L09-02-06-P-E-S-00 (160-17741-1) and (160-17741-A-1 DU). The sample was very fine powder and small rocks.
Batch 255888:
Percent Moisture exceeded the RPD limit for the duplicate of sample 160-17741-1. The initial result was 20.9 % moisture and the duplicate result was 13.6 % moisture yielding an RPD of 42% (30%).
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
CESIUM-137 & OTHER GAMMA EMITTERS (GS)Sample L09-02-06-P-E-S-00 (160-17741-1) was analyzed for Cesium-137 & Other Gamma Emitters (GS) in accordance with DOE
GA-01-R. The samples were dried on 06/09/2016, and prepared and analyzed on 06/10/2016.
Preparation Batch 160-256004:
Radium-226 is reported in these samples at the client's request. Radium-226 is reported from the 609.31 keV line of bismuth-214. Because the samples have not had 21-days of ingrowth, the activity for radium-226 is an estimated value and may be biased low. This bias is caused by the disruption of secular equilibrium between radium-226 and bismuth-214 by the loss of radon-222 during sample preparation. The samples are reported with the MDC achieved. L09-02-06-P-E-S-00 (160-17741-1), (LCS 160-256004/2-A), (MB 160-256004/1-A) and (160-17741-A-1-D DU)
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
TestAmerica St. LouisPage 4 of 15 6/16/2016
123456789
101112
Page 5 of 15
6/16/2016
123456789101112
Procedure HDP-PR-QA-006, Chain of Custody
Page 1 of! Hematite Decommissioning Project !Revision: 4 I I Westinghouse Non-Proprietary Class 3
FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY
Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that !he sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.
Chain of Cutody ID No. I F-060916-01 Pa!!e 111 Project Name:
Westinghouse Electric Company
Contact Person: Clark Evers
Phone Number: 314-810-3336 Sampler Name John Michel
Sample ID Date Time !Matrix
L09-02-06-P-E-S-OO 5/2712016 14:40 I s
Relinquished by: ~
Company Name: VJ·C.C-
Received bv:
Company Name:
~~15
Date/Time
(,,.,.-ct-1-t.c c'ioo
Date/Time
Date/Time
0...-cz - (p \\ · -~~
Company Name:
Laboratory Name: TA-MO
Laboratory Address: 13715 Rider Trail North
~ 1--~~~~~~~~~~~~~~~~~~--t ·§ PhoneNo. 8 314-298-8566 ]I Laboratory Contact Person: ~ Ivan Vania
Phone No. 708-870-8453
Turn Around Time Rush (7 days)
Remarks l ILSA09-02
1l Hill II \~ I l l 11 II 160-177 41 Ch;;1in of Custody
--,.d<'-- ---------1
Total I Cooler Temperatun::: 1 Ambient
Cooler ID: I Shipper and Number: 0608-01
Date/Time I Comments: NIA
Verified By:
Login Sample Receipt Checklist
Client: Westinghouse Electric Company LLC Job Number: 160-17741-1
Login Number: 17741
Question Answer Comment
Creator: Dedner, Connie L
List Source: TestAmerica St. Louis
List Number: 1
TrueRadioactivity wasn't checked or is </= background as measured by a survey meter.
TrueThe cooler's custody seal, if present, is intact.
N/ASample custody seals, if present, are intact.
TrueThe cooler or samples do not appear to have been compromised or tampered with.
TrueSamples were received on ice.
TrueCooler Temperature is acceptable.
TrueCooler Temperature is recorded.
TrueCOC is present.
TrueCOC is filled out in ink and legible.
TrueCOC is filled out with all pertinent information.
TrueIs the Field Sampler's name present on COC?
TrueThere are no discrepancies between the containers received and the COC.
TrueSamples are received within Holding Time (excluding tests with immediate HTs)
TrueSample containers have legible labels.
TrueContainers are not broken or leaking.
TrueSample collection date/times are provided.
TrueAppropriate sample containers are used.
TrueSample bottles are completely filled.
TrueSample Preservation Verified.
TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs
N/AContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").
TrueMultiphasic samples are not present.
TrueSamples do not require splitting or compositing.
N/AResidual Chlorine Checked.
TestAmerica St. LouisPage 6 of 15 6/16/2016
123456789
101112
Definitions/GlossaryTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Qualifiers
Rad
Qualifier Description
U Result is less than the sample detection limit.
Qualifier
Glossary
These commonly used abbreviations may or may not be present in this report.
¤ Listed under the "D" column to designate that the result is reported on a dry weight basis
Abbreviation
%R Percent Recovery
CFL Contains Free Liquid
CNF Contains no Free Liquid
DER Duplicate error ratio (normalized absolute difference)
Dil Fac Dilution Factor
DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample
DLC Decision level concentration
MDA Minimum detectable activity
EDL Estimated Detection Limit
MDC Minimum detectable concentration
MDL Method Detection Limit
ML Minimum Level (Dioxin)
NC Not Calculated
ND Not detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit
QC Quality Control
RER Relative error ratio
RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points
TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TestAmerica St. Louis
Page 7 of 15 6/16/2016
123456789
101112
Method SummaryTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method Method Description LaboratoryProtocol
SW8466020A Metals (ICP/MS), Tc-99 TAL SL
EPAMoisture Percent Moisture TAL SL
SW8466020A Metals (ICP/MS), Tc-99 in Activity TAL SL
DOEGA-01-R Cesium-137 & Other Gamma Emitters (GS) TAL SL
Protocol References:
DOE = U.S. Department of Energy
EPA = US Environmental Protection Agency
SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.
Laboratory References:
TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566
TestAmerica St. Louis
Page 8 of 15 6/16/2016
123456789
101112
Sample SummaryTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID Client Sample ID ReceivedCollectedMatrix
160-17741-1 L09-02-06-P-E-S-00 Solid 05/27/16 14:40 06/09/16 11:30
TestAmerica St. Louis
Page 9 of 15 6/16/2016
123456789
101112
Client Sample ResultsTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID: 160-17741-1Client Sample ID: L09-02-06-P-E-S-00Matrix: SolidDate Collected: 05/27/16 14:40
Date Received: 06/09/16 11:30
Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)
Analyte
Actinium 228 0.953
(2σ+/-)
0.147
(2σ+/-)
106/10/16 17:0206/10/16 13:50pCi/g0.0696
RL MDC
0.111
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
pCi/g 06/10/16 13:50 06/10/16 17:02 10.1520.09170.0916U-0.0347Americium 241
pCi/g 06/10/16 13:50 06/10/16 17:02 10.3440.4340.4111.33Bismuth 212
pCi/g 06/10/16 13:50 06/10/16 17:02 10.05530.1080.08080.693Bismuth 214
pCi/g 06/10/16 13:50 06/10/16 17:02 10.05090.1450.06411.01Lead 212
pCi/g 06/10/16 13:50 06/10/16 17:02 10.07180.1190.07960.848Lead 214
pCi/g 06/10/16 13:50 06/10/16 17:02 10.2982.000.99816.9Potassium 40
pCi/g 06/10/16 13:50 06/10/16 17:02 11.880.3550.355U0.000Protactinium 231
pCi/g 06/10/16 13:50 06/10/16 17:02 10.05531.000.1080.08080.693Radium 226
pCi/g 06/10/16 13:50 06/10/16 17:02 10.6501.000.4420.4261.15Thorium 234
pCi/g 06/10/16 13:50 06/10/16 17:02 10.4580.1310.131U0.0531Uranium 235
pCi/g 06/10/16 13:50 06/10/16 17:02 16.783.833.83U2.38Protactinium 234m
pCi/g 06/10/16 13:50 06/10/16 17:02 10.06960.1470.1110.953Thorium 232
Tl-208 0.337 0.0447 0.0567 0.0327 pCi/g 06/10/16 13:50 06/10/16 17:02 1
(2σ+/-) (2σ+/-) MDCRL Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Other Detected
Radionuclides
Uncert. Uncert.
Lab Sample ID: 160-17741-1Client Sample ID: L09-02-06-P-E-S-00Matrix: SolidDate Collected: 05/27/16 14:40
Percent Solids: 79.1Date Received: 06/09/16 11:30
Method: 6020A - Metals (ICP/MS), Tc-99RL MDL
Technetium 99 0.00026 0.000068 0.000021 mg/Kg ☼ 06/13/16 09:12 06/14/16 15:49 1
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Method: 6020A - Metals (ICP/MS), Tc-99 in Activity
Analyte
Technetium 99 4.38
(2σ+/-)
0.432
(2σ+/-)
106/14/16 15:4906/13/16 09:12pCi/g0.2341.37
RL MDC
0.155
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Re 30 - 110
Carrier
06/13/16 09:12 06/14/16 15:49 1
Dil FacAnalyzedPreparedQualifier Limits%Yield
92
TestAmerica St. Louis
Page 10 of 15 6/16/2016
123456789
101112
QC Sample ResultsTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: 6020A - Metals (ICP/MS), Tc-99
Client Sample ID: Method BlankLab Sample ID: MB 160-256106/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256398 Prep Batch: 256106
RL MDL
Technetium 99 ND 0.000053 0.000016 mg/Kg 06/13/16 09:12 06/14/16 15:40 1
MB MB
Analyte Dil FacAnalyzedPreparedDUnitResult Qualifier
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-256106/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256398 Prep Batch: 256106
Technetium 99 0.00119 0.00121 mg/Kg 102 80 - 120
Analyte
LCS LCS
DUnitResult Qualifier %Rec
Spike
Added
%Rec.
Limits
Client Sample ID: L09-02-06-P-E-S-00Lab Sample ID: 160-17741-1 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256398 Prep Batch: 256106
Technetium 99 0.00026 0.00150 0.00178 mg/Kg 101 75 - 125☼
Analyte
MS MS
DUnitResult Qualifier %Rec
Spike
Added
Sample
Result
Sample
Qualifier
%Rec.
Limits
Client Sample ID: L09-02-06-P-E-S-00Lab Sample ID: 160-17741-1 MSDMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256398 Prep Batch: 256106
Technetium 99 0.00026 0.00150 0.00172 mg/Kg 97 75 - 125 3 30☼
Analyte
MSD MSD
DUnitResult Qualifier %Rec
Spike
Added
Sample
Result
Sample
Qualifier
%Rec.
Limits LimitRPD
RPD
Method: 6020A - Metals (ICP/MS), Tc-99 in Activity
Client Sample ID: Method BlankLab Sample ID: MB 160-256106/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256399 Prep Batch: 256106
Technetium 99
Analyte
U 106/14/16 15:4006/13/16 09:12pCi/g0.181
MDC
1.05
RL
0.02180.0210
(2σ+/-) (2σ+/-)
MB
0.06321
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Carrier
Re 30 - 110 06/13/16 09:12 06/14/16 15:40 1
Dil FacPrepared AnalyzedQualifier Limits%Yield
95
MB MB
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-256106/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256399 Prep Batch: 256106
Technetium 99
Analyte
120-8010220.7420.4 1.94 1.05 0.180
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
Re
Carrier
30 - 110
LCS
Qualifier Limits%Yield
95
LCS
TestAmerica St. Louis
Page 11 of 15 6/16/2016
123456789
101112
QC Sample ResultsTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)
Client Sample ID: L09-02-06-P-E-S-00Lab Sample ID: 160-17741-1 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256399 Prep Batch: 256106
Technetium 99
Analyte
125-7510130.4225.74.38 2.91 1.43 0.244
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Re
Carrier
30 - 110
MS
Qualifier Limits%Yield
89
MS
Client Sample ID: L09-02-06-P-E-S-00Lab Sample ID: 160-17741-1 MSDMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256399 Prep Batch: 256106
Technetium 99
Analyte
10.18125-759729.4025.74.38 2.74 1.40 0.239
RL MDC(2σ+/-)
MSD MSD
pCi/g
UnitResult Qual %Rec LimitAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
RER
RER
Re
Carrier
30 - 110
MSD
Qualifier Limits%Yield
91
MSD
Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)
Client Sample ID: Method BlankLab Sample ID: MB 160-256004/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256060 Prep Batch: 256004
Actinium 228
Analyte
U 106/12/16 17:1906/10/16 13:50pCi/g0.0559
MDCRL
0.03050.0305
(2σ+/-) (2σ+/-)
MB
0.01254
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
106/12/16 17:1906/10/16 13:50pCi/g0.02700.01820.0182U-0.004577Americium 241
106/12/16 17:1906/10/16 13:50pCi/g0.3090.07180.0718U-0.01231Bismuth 212
106/12/16 17:1906/10/16 13:50pCi/g0.08060.06510.0651U-0.01247Bismuth 214
106/12/16 17:1906/10/16 13:50pCi/g0.02120.01260.0126U0.006006Lead 212
106/12/16 17:1906/10/16 13:50pCi/g0.05510.03400.0339U-0.02222Lead 214
106/12/16 17:1906/10/16 13:50pCi/g0.3220.2380.238U0.03194Potassium 40
106/12/16 17:1906/10/16 13:50pCi/g0.6430.2700.270U0.1069Protactinium 231
106/12/16 17:1906/10/16 13:50pCi/g0.08061.000.06510.0651U-0.01247Radium 226
106/12/16 17:1906/10/16 13:50pCi/g0.2401.000.07640.0760U0.07467Thorium 234
106/12/16 17:1906/10/16 13:50pCi/g0.1370.06100.0609U-0.03246Uranium 235
106/12/16 17:1906/10/16 13:50pCi/g4.340.4660.466U0.0000Protactinium 234m
106/12/16 17:1906/10/16 13:50pCi/g0.05590.03050.0305U0.01254Thorium 232
Other Detected
Radionuclide
None
MB
(2σ+/-) (2σ+/-) MDCRL
pCi/g 06/10/16 13:50 06/12/16 17:19 1
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Radionuclides
Other Detected
TestAmerica St. Louis
Page 12 of 15 6/16/2016
123456789
101112
QC Sample ResultsTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-256004/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256035 Prep Batch: 256004
Americium 241
Analyte
116-879999.57101 10.4 0.492
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
Cesium 137 33.9 32.90 3.44 0.200 0.158 pCi/g 97 87 - 120
Cobalt 60 30.9 29.58 2.98 0.120 pCi/g 96 87 - 115
Client Sample ID: L09-02-06-P-E-S-00Lab Sample ID: 160-17741-1 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 256042 Prep Batch: 256004
Actinium 228
Analyte
10.171.0050.953 0.162 0.145
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Americium 241 -0.0347 U -0.04368 U 0.110 0.183 pCi/g 0.04 1
Bismuth 212 1.33 1.348 0.432 0.350 pCi/g 0.02 1
Bismuth 214 0.693 0.8010 0.144 0.0852 pCi/g 0.43 1
Lead 212 1.01 1.014 0.154 0.0673 pCi/g 0.03 1
Lead 214 0.848 0.7945 0.120 0.0754 pCi/g 0.23 1
Potassium 40 16.9 18.57 2.33 0.259 pCi/g 0.38 1
Protactinium 231 0.000 U -0.5237 U 1.67 2.79 pCi/g 0.26 1
Radium 226 0.693 0.8010 0.144 1.00 0.0852 pCi/g 0.43 1
Thorium 234 1.15 1.184 0.581 1.00 0.889 pCi/g 0.04 1
Uranium 235 0.0531 U 0.08394 U 0.204 0.340 pCi/g 0.09 1
Protactinium
234m
2.38 U 3.552 U 5.26 9.54 pCi/g 0.13 1
Thorium 232 0.953 1.005 0.162 0.145 pCi/g 0.17 1
Tl-208 10.010.33820.337 0.0718 0.0492
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
RER
RER
Total
Other Detected
Radionuclides
TestAmerica St. Louis
Page 13 of 15 6/16/2016
123456789
101112
QC Association SummaryTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Metals
Prep Batch: 256106
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid None160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid None160-17741-1 MS L09-02-06-P-E-S-00 Total/NA
Solid None160-17741-1 MSD L09-02-06-P-E-S-00 Total/NA
Solid NoneLCS 160-256106/2-A Lab Control Sample Total/NA
Solid NoneMB 160-256106/1-A Method Blank Total/NA
Analysis Batch: 256398
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid 6020A 256106160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid 6020A 256106160-17741-1 MS L09-02-06-P-E-S-00 Total/NA
Solid 6020A 256106160-17741-1 MSD L09-02-06-P-E-S-00 Total/NA
Solid 6020A 256106LCS 160-256106/2-A Lab Control Sample Total/NA
Solid 6020A 256106MB 160-256106/1-A Method Blank Total/NA
General Chemistry
Analysis Batch: 255888
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid Moisture160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid Moisture160-17741-1 DU L09-02-06-P-E-S-00 Total/NA
Rad
Leach Batch: 255856
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid Dry and Grind160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid Dry and Grind160-17741-1 DU L09-02-06-P-E-S-00 Total/NA
Prep Batch: 256004
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid Fill_Geo-0 255856160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid Fill_Geo-0 255856160-17741-1 DU L09-02-06-P-E-S-00 Total/NA
Solid Fill_Geo-0LCS 160-256004/2-A Lab Control Sample Total/NA
Solid Fill_Geo-0MB 160-256004/1-A Method Blank Total/NA
Prep Batch: 256106
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid None160-17741-1 L09-02-06-P-E-S-00 Total/NA
Solid None160-17741-1 MS L09-02-06-P-E-S-00 Total/NA
Solid None160-17741-1 MSD L09-02-06-P-E-S-00 Total/NA
Solid NoneLCS 160-256106/2-A Lab Control Sample Total/NA
Solid NoneMB 160-256106/1-A Method Blank Total/NA
TestAmerica St. Louis
Page 14 of 15 6/16/2016
123456789
101112
Tracer/Carrier SummaryTestAmerica Job ID: 160-17741-1Client: Westinghouse Electric Company LLC
Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: 6020A - Metals (ICP/MS), Tc-99 in ActivityPrep Type: Total/NAMatrix: Solid
Lab Sample ID Client Sample ID (30-110)
Re
92160-17741-1
Percent Yield (Acceptance Limits)
L09-02-06-P-E-S-00
89160-17741-1 MS L09-02-06-P-E-S-00
91160-17741-1 MSD L09-02-06-P-E-S-00
95LCS 160-256106/2-A Lab Control Sample
95MB 160-256106/1-A Method Blank
Tracer/Carrier Legend
Re = Re
TestAmerica St. Louis
Page 15 of 15 6/16/2016
123456789
101112