vtc 3032 / 3022 series - airtec142 specifications subject to change without notice. with air control...
Post on 07-Feb-2021
5 Views
Preview:
TRANSCRIPT
-
Specifications subject to change without notice.138 www.vmeca.com
Patented design.High operational reliability despite fluctuating or low compressed-air pressure.Integrated high dirt holding capacity pleated filter.VMECA Twofold SilencerPT assures low noise levels.Optional Air-Saving(AS) kit available to minimize energy consumption.Optional factory installed Air control/Vacuum release valves and Vacuum switch available.Compact size and light weight.Easily mountable and interchangeable vacuum cartridge.
Max. vacuum level
Max. flow rate
Supply air pressure
Air consumption
Supply air type
Working temperature
Noise level
VTC 3032 / 3022 Series
Main advantages
Order No.
: -93 kPa (-27.46 inHg)
: 688 Nl/min (24.3 scfm)
: 3 ~ 6 bar, max 7 bar(43.5~87 psi, max 101.5 psi)
: 194~304 Nl/min (6.85~10.74 scfm)
: Dry compressed air: -20� to +80�
: 50~60 ㏈A
No mark - Vacuum gauge.
� Remark: ① S..(P)Output type :PNP open collector
② VCM8 42 : M8-4Pin connector wire.Only for type S2 or S2(P).
S2(P) - Digital display output 2points, No analog supplyM8-4Pin Connector type 0.3m lead wire.
SG2(P) - Digital display output 2 points, No analog supplyGrommet type 4-Core 2m lead wire.
SG3(P) - Digital display output 2 points, Analog supplyGrommet type 5-Core 2m lead wire.
Model
Voltage of air supplycontrol valve
Voltage of vacuumrelease control valve
Sealing
VTC 3022 - Two stage nozzleVTC 3032(P) - Three stage nozzle
No mark - StandardAS - Air saving kit
No mark - Standard
V - VitonE - EPDM
� Remark:..(P)
G3/8”Exhaust Port
Non-return valveNo mark - Standard
N - Non-return valve.
A1 - AC110V
A2 - AC220V
A3 - DC24VD1* - AC110V
D2* - AC220V
D3* - DC24V* D.. : Double solenoid valve is
available only with ‘DN’ or ‘DL’, section ⑥
1
4
5
Air saving kit3
8
Vacuum switch7
9
R1 - AC110V
R2 - AC220V
R3 - DC24V
R
④② ③①
VTC 3032 - 2 - AS - A3 R3 - CL - S2 N V⑤ ⑥ ⑦ ⑧
2MaterialPolyester (PE)
Connection portBSP Thread(G)
Filter element & Connection port2
⑨
DN - DIN type without lead wire
DL - DIN type with lamp without lead wire
CL* Connector type with lamp &0.3 m lead wire
2B* DIN type with ‘2 in 1’ BUS cable(Air control v/v + Vacuum release v/v)
Solenoid Terminal6
-
3B* DIN type with ‘3 in 1’ BUS cable(Air control v/v + Vacuum release v/v + Digital switch)
-
-
* Can not available with double solenoid valve� Remark CL : Available only with DC24V3B : Available only with DC24V
Available only with ‘S2’ or ‘S2P’, section ⑦
VACUUM PUMP Midi Turtle Pump
� About ‘BUS cable’ ( 340, 341)
( 108)
-
VAC
UU
M
PUM
PS
139Specifications subject to change without notice. www.vmeca.com
Performance Data
ModelMAX.
Vacuum(- kPa)
Feedpressure(MPa)
0(0)
0.220.30.40.220.30.4
328340342604676682
245304308245304308
176212255176212255
106128188106128188
62.86613862.866138
576486576486
3344
46.63344
46.6
9.233
34.69233
34.6
-12.813.8
-12.813.8
-3.84.2-
3.84.2
Vacuum flow, Nl/min, at different vacuum levels -kPa (-mmHg)
VTC3022..
10(75)
80(600)
70(525)
60(450)
50(375)
40(300)
30(225)
90(675)
20(150)
VTC3032..
VTC3032..
ModelFeed
pressure(MPa)
Airconsumption
(Nl/min)
194236304194236304
Time, s/l, to evacuate a volume to different vacuum levels -kPa (-mmHg)
VTC3022..
10(75)
80(600)
70(525)
60(450)
50(375)
40(300)
30(225)
90(675)
20(150)
0.0180.0160.0140.0110.010.01
0.0650.050.0290.0430.0320.026
0.1080.070.0430.050.0550.037
0.20.160.050.170.150.047
0.250.230.130.230.220.12
0.3950.340.250.380.330.23
0.810.5
0.3550.810.480.35
-0.7950.71
-0.780.7
-2.011.75
-1.981.72
759393759393
0.220.30.40.220.30.4
VTC
-302
2..
VTC
-303
2..
VACUUM PUMP Midi Turtle Pump
-
Specifications subject to change without notice.140 www.vmeca.com
VTCL 3032 / 3022 Series
Patented design.High operational reliability despite fluctuating or low compressed-air pressure.Integrated high dirt holding capacity pleated filter.VMECA Twofold SilencerPT assures low noise levels.Optional Air-Saving(AS) kit available to minimize energy consumption.Optional factory installed Air control/Vacuum release valves and Vacuum switch available.Compact size and light weight.Easily mountable and interchangeable vacuum cartridge.
Main advantages
Max. vacuum level
Max. flow rate
Supply air pressure
Air consumption
Supply air type
Working temperature
Noise level
: -75 kPa (-22.15 inHg)
: 724 Nl/min (25.57 scfm)
: 4 ~ 6 bar, max 7 bar(58~87 psi, max 101.5 psi)
: 140~208 Nl/min (4.94~7.35 scfm)
: Dry compressed air: -20� to +80�
: 50~60 ㏈A
Order No.
No mark - Vacuum gauge.
� Remark: ① S..(P)Output type :PNP open collector
② VCM8 42 : M8-4Pin connector wire.Only for type S2 or S2(P).
S2(P) - Digital display output 2points, No analog supplyM8-4Pin Connector type 0.3m lead wire.
SG2(P) - Digital display output 2 points, No analog supplyGrommet type 4-Core 2m lead wire.
SG3(P) - Digital display output 2 points, Analog supplyGrommet type 5-Core 2m lead wire.
Model
Voltage of air supplycontrol valve
Voltage of vacuumrelease control valve
Sealing
VTCL 3022 - Two stage nozzleVTCL 3032(P) - Three stage nozzle
No mark - StandardAS - Air saving kit
No mark - Standard
V - VitonE - EPDM
� Remark:..(P)
G3/8”Exhaust Port
Non-return valveNo mark - Standard
N - Non-return valve.
A1 - AC110V
A2 - AC220V
A3 - DC24VD1* - AC110V
D2* - AC220V
D3* - DC24V* D.. : Double solenoid valve is
available only with ‘DN’ or ‘DL’, section ⑥
1
4
5
Air saving kit3
8
Vacuum switch7
9
R1 - AC110V
R2 - AC220V
R3 - DC24V
R
④② ③①
VTCL 3032 - 2 - AS - A3 R3 - CL - S2 N V⑤ ⑥ ⑦ ⑧
2MaterialPolyester (PE)
Connection portBSP Thread(G)
Filter element & Connection port2
⑨
DN - DIN type without lead wire
DL - DIN type with lamp without lead wire
CL* Connector type with lamp &0.3 m lead wire
2B* DIN type with ‘2 in 1’ BUS cable(Air control v/v + Vacuum release v/v)
Solenoid Terminal6
-
3B* DIN type with ‘3 in 1’ BUS cable(Air control v/v + Vacuum release v/v + Digital switch)
-
-
* Can not available with double solenoid valve� Remark CL : Available only with DC24V3B : Available only with DC24V
Available only with ‘S2’ or ‘S2P’, section ⑦
VACUUM PUMP Midi Turtle Pump
� About ‘BUS cable’ ( 340, 341)
( 108)
-
VAC
UU
M
PUM
PS
141Specifications subject to change without notice. www.vmeca.com
Performance Data
ModelMAX.
Vacuum(- kPa)
Feedpressure(MPa)
0(0)
0.40.50.60.40.50.6
376390400604688724
316352366352392415
220260308220260308
140164200140164200
9210010492100104
567576567576
13.64664
13.64664
-23.844-
23.844
------
------
------
------
Vacuum flow, Nl/min, at different vacuum levels -kPa (-mmHg)
VTCL3022..
10(75)
80(600)
70(525)
60(450)
50(375)
40(300)
30(225)
90(675)
20(150)
VTCL3032..
607075607075
VTCL3032
ModelFeed
pressure(MPa)
Airconsumption
(Nl/min)
140170208140170208
Time, s/l, to evacuate a volume to different vacuum levels -kPa (-mmHg)
VTCL3022
10(75)
0.0180.0140.0130.0130.0090.006
0.040.0360.0320.0370.0320.03
0.080.0750.060.0730.060.047
0.1450.1250.10.140.1280.098
0.1950.150.1550.190.160.15
0.50.20.180.450.250.2
-0.40.35
-0.430.32
80(600)
70(525)
60(450)
50(375)
40(300)
30(225)
90(675)
20(150)
0.40.50.60.40.50.6
VTC
L-30
22..
VTC
L-30
32..
VACUUM PUMP Midi Turtle Pump
-
Measure unit : mm [in]
Specifications subject to change without notice.142 www.vmeca.com
With Air Control valve, Vacuum Release Control valve and Digital Vacuum Switch
With Air Control valve, Vacuum Release Control valve and Digital Vacuum Switch
VTC 3022.. / VTCL 3022..
VTC 3032.. / VTCL 3032..
Dimensional Information
Measure unit : mm [in]
VACUUM PUMP Midi Turtle Pump
-
VAC
UU
M
PUM
PS
143Specifications subject to change without notice. www.vmeca.com
Standard
Standard
VTC 3022.. / VTCL 3022..
Dimensional Information
VTC 3032.. / VTCL 3032..
Measure unit : mm [in]
VACUUM PUMP Midi Turtle Pump
Measure unit : mm [in]
top related