u.s. consulate general (erbil) s-094 building renovation … · a1.1erbil, ankawa, s-094 building -...
Post on 03-Jul-2020
2 Views
Preview:
TRANSCRIPT
N
EW
S
S-095
U.S. CONSULATE GENERAL
(ERBIL) S-094 BUILDING
RENOVATION
Overseas Buildings Operations
Washington, DC
G1.0
OCT 2018
OCT 2018
ERBIL, ANKAWA, S-094 BUILDING RENOVATION PROJECTG1.0
Scale: NTS
Site Plan
S-094Street
1
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
INDEX OF DRAWING
G1.0 COVER SHEET
1
2
3
4
5
6
7
8
9
10
G1.1
G1.2
A1.0
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
TABLE OF CONTENT
INDEX OF ROOMS
U.S. CONSULATE GENERAL
(ERBIL) S-094 BUILDING
RENOVATION
Overseas Buildings Operations
Washington, DC
G1.1
OCT 2018
OCT 2018
ERBIL, ANKAWA, TABLE OF CONTENT G1.1
Scale: NTS2
CURRENT BUILDING PLAN
DEMOLISH AND RENOVATION PLAN
PROPOSED LIGHTING DISTRIBUTION PLAN
PROPOSED RECEPTACLES DISTRIBUTION PLAN
PROPOSED SANITARY PLAN
PROPOSED FIRE EXTINGUISHERS PLAN
11
12
A1.7
A1.8
PROPOSED BUILDING LAYOUT
BUILDING FRONT VIEW AND SECTION
PROPOSED AIR-CONDITIONING AND WATER HEATERS PLAN
13
14
G1.3
PROPOSED DOORS AND WINDOWS INDEX
PROPOSED THREE PHASE WIRING INSTALLATION PLAN
A1.9
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
1ST FLOOR, LIVING ROOM
1ST FLOOR, BATHROOM
1ST FLOOR, HALL WAY
1ST FLOOR, GARDEN
1ST FLOOR, MULTI PURPOSE OUTSIDE HALL
2ND FLOOR, MASTER BEDROOM
2ND FLOOR, SETTING AND TV ROOM
2ND FLOOR, HALLWAY
1
2
3
4
5
6
7
8
9
11
12
13
1ST FLOOR, BEDROOM#1
OCT 2018
ERBIL, ANKAWA, S-094 BUILDING - INDEX OF ROOMSG1.2
Scale: NTS
3
14
15
16
17
18
1ST FLOOR, KITCHEN
1ST FLOOR, BEDROOM#2
1ST FLOOR, RESTROOM
2ND FLOOR, BATHROOM
FIRST FLOOR ROOF
2ND FLOOR, OUTDOOR RESTROOM
BALCONY
TOP ROOF19
1ST FLOOR, ENTRANCE
INDEX OF CURRENT ROOMS
1ST FLOOR, LIVING ROOM
1ST FLOOR, BATHROOM
1ST FLOOR, HALL WAY
1ST FLOOR, GARDEN
1ST FLOOR, ALLEY, SIDE YARD
2ND FLOOR, BEDROOM#3
2ND FLOOR, LAUNDRY
2ND FLOOR, HALLWAY
1
2
3
4
5
6
7
8
9
11
12
13
1ST FLOOR, BEDROOM#1
14
15
16
17
18
1ST FLOOR, KITCHEN
1ST FLOOR, BEDROOM#2
1ST FLOOR, UNDER STAIR STORE
2ND FLOOR, BATHROOM
2ND FLOOR, OUTDOOR STORAGE
BALCONY
TOP ROOF19
1ST FLOOR, STORAGE
INDEX OF PROPOSED ROOMS
FIRST FLOOR ROOF
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
DOOR LABEL
DOOR SIZE
WIDTH(MM)HEIGHT(MM)
TYPEFINISH
10002100
WOOD WOODEN FRAME WITH SOLID HARDWARE
WOOD
WINDOW LABEL
ROUGH PENNING
WIDTH(MM)HEIGHT(MM)
VIEW
2000 1500
50
1500
15001000
650 1500
2400 1500
2000 1500
500 1400
W001
W002
W003
W004
W005
W006
W007
W009
W010
D001
D002
D003
D004
D006
D007
D008
D009
D010
D011
WOOD
D005
WOODEN FRAME WITH SOLID HARDWARE
WOODEN FRAME WITH SOLID HARDWARE
OCT 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED DOORS AND WINDOWS INDEXG1.3
Scale: NTS
4
WINDOW SPECIFICATION
Aluminum window with 6 mm double
tinted float colored glazing, screen,
handle and all other accessories.
Install window with emergency
escape egress. and install steel grille
with max. space between bars not
exceed 10cm.
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
WOOD
1000
1000
1000
2100
2100
2100
WOODEN FRAME WITH SOLID HARDWARE
1000
1000
2100
2100
WOOD
WOOD
STEEL DOOR OIL BASE PAINTED STEEL2100
2100
2100
2100
1000
1000
1000
1000
WOODEN FRAME WITH SOLID HARDWARE
WOODEN FRAME WITH SOLID HARDWARE
STEEL DOOR OIL BASE PAINTED
STEEL DOOR OIL BASE PAINTED
STEEL DOOR OIL BASE PAINTED
D012
STEEL
STEEL
STEEL
ALUMINUM
ALUMINUM
ALUMINUM FRAME AND DOOR
ALUMINUM FRAME AND DOOR
2100
2100
900
900
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
Aluminum window with 6 mm double
tinted float colored glazing, screen,
handle and all other accessories.
Install window with emergency
escape egress. and install steel grille
with max. space between bars not
exceed 10cm.
Aluminum window with 6 mm double
tinted float colored glazing, screen,
handle and all other accessories.
Install window with emergency
escape egress. and install steel grille
with max. space between bars not
exceed 10cm.
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
W008
2400
1500
500
1200
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
Note\ Two windows with same
size to be installed.
1400
1800
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
W011
14001200
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
W012
500
1200
Aluminum window with 6 mm
double tinted float colored
glazing, screen, handle and all
other accessories.
W013
14001800
Aluminum window with 6 mm double
tinted float colored glazing, screen,
handle and all other accessories.
Install window with emergency
escape egress. and install steel grille
with max. space between bars not
exceed 10cm.
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Sandwich panel room
Kitchen
Living Room
Bathroom
BedroomBedroom
A105
A101
A103
A104
A102
A100
A106
A107
A201
A202
A203
A205
A204
A206
A207
Bare slab Roof
Top Roof
Remove the existing
sandwich panel and
roof
A301
OCT, 2018
First Floor
ERBIL, ANKAWA, S-094 BUILDING - CURRENT BUILDING PLANA1.0
Scale: NTS
5
Second Floor Top Roof
A108
A109
Bedroom
Setting room
Bathroom
Balcony
First Floor Roof
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Kitchen
BedroomBedroom
Bedroom
Living Room
Laundry Room
3.54
1.59
1.65
2.88
0.75
1.65 2.88
1.65
A
A
A
A
A
A
A
A
A
G
G
A
B
B
B
B
F
B
B
B
B
B
C
C
A
D
D
D
D
D
D
D
D
E
F
F
F
B
F
G
E
H
H
H
H
I I
I I
II
J
J
F
Demolish existing wall/under the existing Lintel
for new doorway. Provide and install new steel
access door.
Re-build interior partition wall by using
hollow concrete block and cement and
stand mortar .
A
Demolish existing floor tiles, provide and install
new anti-slip ceramic floor tiles.
B
Remove the existing plastering , re-plastering by
proper ,materials and paintings .
C
Remove the existing wall and floor tiles,
provide and install new tiles .
D
Remove existing windows, provide and install
new aluminum windows .
E
F
G
Provide and install waterproofing
material, install new tiles.
I
Remove existing Interior doors, correct the door
dimensions to meet the IBC standers, provide
and install new wooden doors .
J Remove existing bathroom doors, correct the door
dimensions to meet the IBC standers, provide and
install new aluminum doors .
First Floor
Second Floor Top Roof
G
H
Remove existing exterior doors, correct the door
dimensions to meet the IBC standers, provide
and install new steel doors .
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - DEMOLISH AND RENOVATION PLANA1.1
Scale: NTS6
K
Provide and install Skirting 10cm height to the
interior and exterior walls.
L
L
L
Remove the existing oil painting of the steel
columns, re-paint it with three layer oil paint.
G
G
G
M
Remove the existing balcony Railing and install
new steel railing according to IBC standers, paint it
with three layer oil paint.
N
Remove the existing Stair Railing and install new
steel railing according to IBC standers, paint it with
three layer oil paint.
13.22
7.27
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Bedroom
BedroomLiving Room
Laundry Room
1.86
3.25
1.863.25
1.86
First Floor
Second Floor Top Roof
Bedroom
4.20
4.85
0.70
4.57
5.05
2.60
3.00
0.71
4.35
1.70
2.40
4.20
9.65
4.00
3.00
0.90
8.53
1.53
1.80
1.86
0.71
0.90
2.26
9.95
7.96
3.766.89
3.60
AAA
A
AA
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED BUILDING LAYOUT A1.2
Scale: NTS7
Alley
Alley
A100
A101
A102
Kitchen
STORAGE
1.40
1.80
A103A104
A106
A105
A108
A201
4.00
A202
A205
A207
Bare slab Roof
Top Roof
A301
First Floor Roof
4.48
Balcony
D001D002
D004D003
D006
D005
D012
D011
D010
D009D008
5.05
D007
W001
W002
W003
W00
6
W0
04
W0
05
W00
7W
00
8
4.00
1.86
4.00
W0
10
W0
11
W0
13
W0
12
W0
09
B
New Perimeter wall
hollow concrete
1.65m high X 0.2m thickness
provide and install support
columns every 2.5m, cement
plastering and painting
B
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
+0.20 m
+3.30 m
+6.10 m
+7.50 m
+0.00 m
Front View
+3.30 m
+0.00 m
+6.40 m
+7.50 m
Section A-A
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - BUILDING VIEW AND SECTIONA1.3
Scale: NTS8
1.50
G
1.40
K
A
A
DD
D
D
I
I
N
B
B
B
B
B
H
HJ
J
C
C
C
C
B
B
L
A
1.10
1.10
1.10
Waterproofing materials/three layers of Epoxy
2mm thick polyethylene barrier
5cm thick lean concrete layer
Anti-slip ceramic tiles dimension 30cm X 30 cm
Joints fill by grouting
Details 1 of Roof Waterproofing
UP
0.50m
0.95m
0.60m
7 cm x 5cm semi-curved
top hollow section
1.10m1.10m
7cm x 5cm semi-curved
top hollow section
4cm x 4cm square
hollow section
Rounded corner
Rounded corner
4cm x 4cm rectangular
hollow section every 10
cm c/c
7cm x 5cm semi-curved
top hollow section
4cm x 4cm square
hollow section
Rounded corner
7cm x 5cm semi-curved
top hollow section
SECTION B-B
M
B
Demolish existing wall/under the existing Lintel
for new doorway. Provide and install new steel
access door.
Re-build interior partition wall by using
hollow concrete block and cement and
stand mortar .
A
Demolish existing floor tiles, provide and install
new anti-slip ceramic floor tiles.
B
Remove the existing plastering , re-plastering by
proper ,materials and paintings .
C
Remove the existing wall and floor tiles,
provide and install new tiles .
D
Remove existing windows, provide and install
new aluminum windows .
E
F
G
Provide and install waterproofing
material, install new tiles.
I
Remove existing Interior doors, correct the door
dimensions to meet the IBC standers, provide
and install new wooden doors .
J Remove existing bathroom doors, correct the door
dimensions to meet the IBC standers, provide and
install new aluminum doors .
H
Remove existing exterior doors, correct the door
dimensions to meet the IBC standers, provide
and install new steel doors .
K
Provide and install Skirting 10cm height to the
interior and exterior walls.
L
Remove the existing oil painting of the steel
columns, re-paint it with three layer oil paint.
M
Remove the existing balcony Railing and install
new steel railing according to IBC standers, paint it
with three layer oil paint.
N
Remove the existing Stair Railing and install new
steel railing according to IBC standers, paint it with
three layer oil paint.
Cement& sand mortar 1:3
plastering+ 3 coats of approved
outdoor paintings.
10 cm thick compacted crushed
stone.
2mm thick nylon
barrier.
P.C, 1:2:4, using Sulfate Resisting
Cement, 40cm thick.
1.6m high wall, 20 cm thick
building by hollow concrete block
20X20X40 cm and cement and
sand mortar 1:3.
compacted sub-grade
Cement& sand mortar 1:3
plastering+ 3 coats of approved
outdoor paintings.
STAIRCASE AND RAILING PLAN
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
LED LIGHTING
Single Pole One Way Switch
Circut Breaker
Exhaust Fan
Electrical Board
LED Panel Light 24-Watt
Two Way Switch
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
Cable 3X2.5 mm
First Floor
Second Floor
Top Roof
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED LIGHTING DISTRIBUTION PLAN A1.4
Scale: NTS9
Exterior LED lights shall be
waterproof type
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Circuit Breaker
Outlet 13 &15 A
GFCI Outlet 15 A
Electrical Boarder
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
Cable 3X4 mm
First Floor
Second Floor
Top Roof
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED RECEPTACLES DISTRIBUTION PLANA1.5
Scale: NTS
10
Exterior Outlets shall
be connected to GFCI
breakers and have
protection cover.
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED THREE PHASE WIRING INSTALLATION PLAN
Scale: NTS
A1.6
11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
31
30
29
28
27
26
25
24
23
22
32
33
34
35
36
37
38
39
40
41
42
R
Y
B
N
Main
Circuit
Breaker
63 A,
Molded
Case
Circuit
Breaker
(MCCB)
R
Y
B
N
R
Y
B
21
20
19
18
17
16
15
14
12
11
10
9
8
7
6
5
13
4
3
2
1
21
20
19
18
17
16
15
14
12
11
10
9
8
7
6
5
13
4
3
2
1
22
23
24
25
26
27
28
29
31
32
33
34
35
36
37
38
30
39
40
41
42
22
23
24
25
26
27
28
29
31
32
33
34
35
36
37
38
30
39
40
41
42
Grounding
Electrode
Neutral C
onductors
Grounding C
onductors
Neutral C
onductors
Grounding C
onductors
Circuit Breaker
63 A
III-Phase,
4
Wire
System
Compound
Grid
Copper
Busbar
Strip
Circuit Breaker vs Wire Size Schedule
BreakerNo. Description/Room Floor Fixture Breaker
Type
BreakerSize
(Amperes)
Wire Size(mm2)
1 Bedroom 1 First floor Lights MCB 10 1.52 Bedroom 2 First floor Lights MCB 10 1.53 Hallway First floor Lights MCB 10 1.54 Kitchen First floor Lights & Exhaust fan MCB 10 1.55 Formal living room First floor Lights MCB 10 1.56 Bathroom First floor Lights & Exhaust fan MCB 10 1.57 Outdoor 1 First floor Lights MCB 10 1.58 Outdoor 2 First floor Lights MCB 10 1.59 Master Bedroom Second floor Lights MCB 10 1.5
10 Bathroom Second floor Lights & Exhaust fan MCB 10 1.511 Laundry Second floor Lights MCB 10 1.512 Hallway Second floor Lights MCB 10 1.513 Outdoor - Front Side Second floor Lights MCB 10 1.514 Outdoor - Back Side Second floor Lights MCB 10 1.515 Bedroom 1 First floor Outlets MCB 25 4
16 Bedroom 2 First floor Outlets MCB 25 417 Hallway First floor Outlets MCB 25 418 Formal living room First floor Outlets MCB 25 419 Kitchen First floor Outlets GFCI 25 420 Outdoors First floor Outlets GFCI 25 421 Bathroom First floor Outlets GFCI 25 422 Water pump First floor Outlet GFCI 16 2.523 Water Heater First floor Switch GFCI 25 424 Master Bedroom Second floor Outlet MCB 25 425 Laundry Second floor Outlet GFCI 25 426 Hallway Second floor Outlets MCB 16 2.527 Bathroom Second floor Outlets GFCI 25 428 Outdoor - Front Side Second floor Outlets GFCI 25 429 Outdoor - Back Side Second floor Outlets GFCI 25 430 Top Roof Pump Second floor Outlet GFCI 10 2.531 Bedroom 1 First floor AC Unit MCB 25 432 Bedroom 2 First floor AC Unit MCB 25 433 Formal living room First floor AC Unit MCB 25 434 Kitchen First floor AC Unit MCB 25 435 Master Bedroom Second floor AC Unit MCB 25 436 Laundry
Second floor
AC unit
MCB 16 2.537 Spare MCB 1638 Spare MCB 1639 Spare MCB 2540 Spare MCB 2541 Spare GFCI 2542 Spare GFCI 25
43 Main Breaker (III-Phase) First floor MCB 63 16
44 Circuit Breaker (III-Phase) First floor MCCB 63 16
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Power Point 45 Amp.
Condenser - AC Outdoor unit
AC indoor unit
Electrical Water Heater
First Floor
Second Floor Top Roof
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED AIR-CONDITIONING AND WATER HEATERS PLANA1.7
Scale: NTS12
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
Existing Cesspool
Ex
is
tin
g G
ra
y W
ate
r (M
un
ic
ip
ality
) S
ew
er
W D
Sewage Manhole 40x40 cm
Collection Manhole 15x15 cm
UPVC Floor Drain PIPE 4"
GRAY Water - light Sewer UPVC line 4"
BLACK Water - Heavy Sewer PVC line 4"
First Floor
Second Floor
Top Roof
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED SANITARY PLANA1.8
Scale: NTS13
GRAY Water - light Sewer UPVC line 6"
BLACK Water - Heavy Sewer PVC line 6"
PLASTIC Water TANK
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
FIRE EXTINGUISHER
SMOKE DETECTOR
First Floor
Second Floor
Top Roof
OCT, 2018
ERBIL, ANKAWA, S-094 BUILDING - PROPOSED FIRE EXTINGUISHERS PLANA1.9
Scale: NTS
14
D a t e:
R e v i s i o n:
P r o j e c t:
S c a l e :
D r a w i n g T i t l e:
R e v i s i o n n o t e s:
Rev: Date: Notes:
Approved by:
Checked by:
U.S. ConsulateGeneral Erbil,
Iraq
Facility Manager:
Drawn by:
Sheet Number:
Ayan Abdoka
Arsalan Ali
Kevin Lanning Renovation of S-094 building10/03/2018
NTPPaper Size :11" X 17"
Sensitive but Unclassified (SBU)
Kevin Lanning
top related