ultimate protect wired mat 4.0/4.0 alu1 black - isover · saint gobain isover ibérica, s.l....

Post on 13-Oct-2018

226 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

DescriptionRolls of high-density, ISOVER ULTIMATE wool, reinforced with a galvanised steel mesh; · ULTIMATE Protect Wired Mat 4.0 not covered.· ULTIMATE Protect Wired Mat 4.0 Alu1 the external facing

is covered with reinforced aluminium foil which acts as a vapour barrier.

ApplicationsBecause of its exceptional thermal and acoustic properties and excellent fire-safety behaviour, the ULTIMATE Protect range is the ideal solution for external insulation, capable of providing fire resistance in:· Networks of circular section metal air-distribution ducts

in thermal installations in buildings, both residential and industrial.

Technical properties

Advantages· Maximum protection against fire, in accordance with EN 13501-1.

· Fire resistant in section metal air-distribution ducts . In accordance with EN 13501-3, EN 1366-1 and EN 1366-8.

· Quick and easy installation.· Up to 65% lighter than conventional products.· Maximum compressibility, highly reliable and adaptable.· Easy to transport.· Optimal thermal and acoustic performance with low thickness solutions.

· Meets the highest safety standard guidelines· Inert material, inhospitable for micro-organisms.· Sustainable product. 100% recyclable. Recycled material > 50%

PresentationThickness

d (mm)Length

l (m)Width b (m)

m2/package

m2/pallet

m2/truck load

30 10.00

0.60

12.00 216.00 4.752

40 7.50 9.00 162.00 3.564

60 6.00 7.20 129.60 2.851

70 5.00 6.00 108.00 2.376

80 4.00 4.80 86.40 1.900

90 3.30 3.96 71.28 1.568

100 3.00 3.60 64.80 1.426

120 2.50 3.00 54.00 1.188

ULTIMATE PROTECT WIRED MAT 4.0/4.0 ALU1 BlackFire protection in circular metal ducts.

Thicknessd, mm

Designation codeISOVER solution

ULTIMATE ProtectEN 823 EN 14303

30-120 MW-EN 14303-T2-ST(+)400Wired Mat 4.0

Wired Mat 4.0 Alu1

Installation GuideConsult the guidelines in the Protect Assembly Manual.Additional information available at: www.isover.es

i→o = interior, o→i = exterior, i↔o = both. ho = horizontal, ve = vertical, ve and ho = both

Construimos tu Futuro

+34 901 33 22 11

www.isover.es

isover.es@saint-gobain.com

www.isover-aislamiento-tecnico.es

@ISOVERes

isoveresISOVERaislamientoISOVERaislamiento

Sain

t G

obai

n Is

over

Ibér

ica,

S.L

. res

erve

s th

e ri

ght

to m

odif

y, t

otal

ly o

r p

arti

ally

an

d w

ith

out

pri

or n

otifi

cati

on, t

he

info

rmat

ion

con

tain

ed h

erei

n. L

ikew

ise,

th

e ab

sen

ce o

f u

nin

ten

tion

al e

rror

s ca

nn

ot b

e gu

aran

teed

. 11/

04/1

6

Insulation thickness needed (Both fire scenarios: interior and exterior)

Type of ductFire-resistance classification Duct

orientationEI 60 EI 90 EI 120

Multisector extraction and

ventilation75 100 120

Both (Horizontal and Vertical)

Symbol Parameter Icon Units Value Standard

lD

Thermal conductivity declared as a function of temperature

W/m·K (°C)

0,031 (10)

EN 12667 EN 12939

0,035 (50)0,040 (100)0,047 (150)0,054(200)0,072 (300)0,096 (400)

Sound absorption coefficient a

w1,00 EN 11654

Air flow resistance(measurement on non-faced product)

AFR

60 EN 29053

Reaction to fire Euroclass A1 EN 13501-1EN 15715

Fire resistance - From EI15 to EI120 EN 1366

ST Maximum operating temperature °C 400 EN 14706

MUMineral wool: water-vapour diffusion resistance,m

- 1 EN 12086

Z Facing: water-vapour diffusion resistance m2•h•Pa/mg

MU1 (4,0)EN 12086

MV2 (4.0 Alu1)

MVThe vapour diffusion-equivalent air layer thickness, Sd

m 200 EN 12086

Certification

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•Qualité

del'a

irin

térie

ur· Calidad aire interior ·Q

ualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

top related