tile tech pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck...
Post on 10-Jul-2020
6 Views
Preview:
TRANSCRIPT
Paving America one step at a time!Tile Tech Pavers®
Uni-Just™ & Stak-Cap™ Pedestal System
Single Model Design PVC Pipe Adjustable Self-LevelingScrew Adjustable Stackable
Pat. # 8,453,391 & Pat. Pen
HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS
TILE TECH PEDESTAL SYSTEMTABLE OF CONTENTS
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 2
3. COMPONENTS LIST
7. INSTALLATION INSTRUCTIONS UNI-JUST™ PEDESTALS
5. INSTALLATION INSTRUCTIONS STAK-CAP™ PEDESTALS
4. COMPONENT ASSEMBLY INSTRUCTIONS STAK-CAP™ PEDESTALS
6. COMPONENT ASSEMBLY INSTRUCTIONS UNI-JUST™ PEDESTALS
8. BASE SLOPE COMPENSATION
9. UNI-SHIM™ APPLICATION
10. PEDESTAL COMBINATION & CONFIGURATION
11. SAMPLE DECK LAYOUT - OVERVIEW
12. SAMPLE INITIAL INSTALLATION
13. THRESHOLD PEDESTAL APPLICATION
14. RADIUS PEDESTAL APPLICATION
16. DIAGONAL PERIMETER APPLICATION
17. LOW HEIGHT PEDESTAL APPLICATION
18. DRAIN PEDESTAL APPLICATION
20. PERIMETER EDGE RESTRAINT STEP-DOWN AND GREEN ROOF CONTAINMENT
19. PERIMETER EDGE RESTRAINT METAL FLASHING AND WOOD FASCIA CONTAINMENT
21. STEP-DOWN PEDESTAL APPLICATION
22. IPE WOOD TILE APPLICATION
23. WOOD TILES 20X20 DETAILS
24. WOOD TILES 24X24 DETAILS
25. JOIST DECK PEDESTAL APPLICATION
26. WIN-LOC™ PAVER PAVER LOCK DOWN SYSTEM FOR WIND UPLIFT.
27. HEX-TRAY™ PAVER SNOW MELT SYSTEM.
15. CORNER PEDESTAL APPLICATION
TILE TECH PEDESTAL SYSTEMCOMPLETE PRODUCT LINE & COMPONENTS LIST
MODEL NUMBER DESCRIPTIONPRODUCT LINE
SPACERS 1/8” & 1/4”
UNI-SHIM™ - 1/8” & 1/16”
ALLOW FOR 1/8” SPACING GAP BETWEEN PAVERS FOR DRAINAGE. TABS A PERFORATED FOR EASY REMOVAL.
USED FOR FINE TUNING OF INDIVIDUAL PAVERS. CAN BE USED ON TOP OR BOTTOM OF PEDESTALS. CAN BE STACKED & BROKEN IN TO QUARTERS OR HALVES.
UNI-INSERT™ -75 (3/4”)USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 3/4” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.
BUFFER PAD
PROVIDES PROTECTION TO WATERPROOFING MEM-BRANE FROM WEAR AND PROVIDES SLIP RESISTANCE TO PEDESTAL. ATTACHES TO BOTTOM OF BASE. ALIGN PERIMETER NOTCHES WITH CHALK LINES.
UNI-COLLAR™
USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL SYSTEM. COMPRESSION FITS ON TO TOP END OF PVC PIPE.
SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE. ALIGN & LOCK TO UNI-INSERT™.
UNI-CAP™
STAK-CAP™USED OF LOW HEIGHT REQUIREMENTS. ROTATE AND STACK CAPS FOR SLOPE & HEIGHT ADJUSTMENT. CAN ALSO BE USED WITH PVC PIPE TO REACH 12” MAX.
UNI-BASE™
USED AS BASE OF PEDESTAL SYSTEM. COMPRESSION FITS ON TO END OF PVC PIPE. CAN ALSO BE USED WITH UNI-INSERT™ FOR LOW HEIGHT APPLICATIONS. LARGE SURFACE AREA PROVIDE ADDED STABILITY.
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
UNI-INSERT™ -150 (1-1/2”)
USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 1-1/2” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 3
USED FOR SLOPE COMPENSATION AT BASE OF PEDESTALS. EACH PLATE COMPENSATES FOR 1/4” PER FOOT (2%) SLOPE AND ADDS 3/8” TO THE OVERALL HEIGHT OF PEDESTAL. MAXIMUM OF FOUR PLATES MAY BE STACKED FOR COMPEN-SATION OF UP TO 1” PER FOOT (0-8%) SLOPE.
BASE SLOPE PLATE (BSP)
STAK-CAP™ PEDESTAL SYSTEM
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
CONFIGURATION CHART:1 CAP = 5/8” HIGH 1/8” PER FOOT 1% MAX2 CAPS = 1” HIGH 1/4” PER FOOT 2% MAX (A+A)3 CAPS = 1-3/8” HIGH 3/8” PER FOOT 3% MAX (A+A+A)4 CAPS = 1-7/8” HIGH 1/2” PER FOOT 4% MAX (A+A+A+A)5 CAPS = 2-1/4“ HIGH 5/8” PER FOOT 5% MAX (A+A+A+A+A)
PVC + 2 CAPS = VARIABLE HEIGHT 0% MAXPVC + 3 CAPS = VARIABLE HEIGHT 1% MAXPVC + 4 CAPS = VARIABLE HEIGHT 2% MAXPVC + 5 CAPS = VARIABLE HEIGHT 3% MAX
COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 1/2” TO 12” & SLOPE ADJUSTMENT FROM 0% TO 5%
PRODUCT CHARACTERISTICS:EACH CAP WILL COMPENSATE FOR UP TO 1/8” PER FOOT SLOPE (1%) & ADD 3/8” TO THE OVERALL HEIGHT OF A PEDESTAL. PVC PIPE CAN BE USED TO GAIN ADDITIONAL HEIGHT OF 12” MAX. ROTATE ONE CAP RELATIVE TO ANOTHER BY ALIGNING THE ALPHABETS TO CHANGE SLOPE. A & A WILL REACH MAXIMUM SLOPE AND A & E WILL CANCEL SLOPE. A MAXIMUM OF 5 CAPS CAN BE STACKED WITH TOTAL SLOPE OF 5/8” PER FOOT (5%) & WITH TOTAL HEIGHT OF 2-1/4” INCLUDING THE USE OF BUFFER PADS.
STACK
ROTATE
4“ø SDR35 P
VC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 4
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
STAK-CAP™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS - 1/2” to 12” HIGH & 0%-3% SLOPE
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
3. Cut PVC pipe to required height with a 12” chop saw. Using sand paper remove any burrs from cut ends.
9. Use a spirit level to check level and use additional half or quarter Uni-Shims™ for fine tuning of individual corners.
1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.
8. Use a spirit level to check level and use additional half or quarter Uni-Shims™ for fine tuning of individual corners.
7. Adjust final pedestal height by using Uni-Shims™ whole or in segments at the top or bottom of pedestal assembly.
Final project grade
Laser line
2. Using a laser determine final height of pedestals. From ½” to 1-½” high no PVC pipe required. Measure & mark PVC pipe to be cut & deduct ¼” for base & cap assembly.
4“ø SDR35 P
VC
4“ø SDR35 P
VC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 5
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
4. Assemble by inserting Stak-Cap™ on to one end of cut PVC pipe and another Stak-Cap™ on to other end of PVC pipe. The Stak-Cap™ is designed to compres-sion fit with PVC pipe.
4“ø SDR35 P
VC
5. Complete assemble by rotating & aligning alphabets of 3rd Stak-Cap™ with the top Stak-Cap™ for slope compensa-tion. Align & attach Buffer Pad to the bottom Stak-Cap™.
Laser line
6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Orient the pedestal assembly so that the top Stak-Cap™ pair high side points towards decline of slope.
NotchChalk line
Deck
4“ø SDR35 P
VC
Level
4“ø SDR35 P
VC
4“ø SDR35 P
VC
4“ø SDR35 P
VC
4“ø SDR35 P
VC
4“ø SD
R35 P
VC
Leveling Shims
Level
STACK
ROTATE
UNI-JUST™ PEDESTAL SYSTEM
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
PRODUCT CHARACTERISTICS:ADJUSTABLE HEIGHT FROM 2-1/4” TO 22” WITH USE OF 4”ø SDR35 PVC PIPE.SELF-LEVELING CAP AUTOMATICALLY ADJUST SLOPE FROM 0% TO 4%.SCREW ADJUSTABLE WHILE PEDESTALS ARE LOADED FOR FINAL HEIGHT ADJUSTMENT OF 1-1/2”RESISTANT & IMPERVIOUS TO FREEZE-THAW, WATER, MOLD, ACID & ULTRAVIOLET DETERIORATION.RESISTANT TO TEMPERATURES BETWEEN -22°F AND +250°F.LARGE FOOT PRINT SPREADS WEIGHT OVER ROOFING MEMBRANE AND SUBSTRATEBUFFER PADS PROVIDE NOISE DAMPENING, SLIP RESISTANCE AND PROTECTION TO ROOFING MEMBRANE AND SUBSTRATE.MAXIMUM DESIGN CAPACITY OF 2,OOO LBS PER PEDESTAL.
4“ø SDR35 P
VC
SPACER TABS - 1/8” TABS CAN BE BROKEN OFF ALLOW DIFFERENT PAVING CONFIGURATION
UNI-CAP™SELF-LEVELING & ADJUSTABLEIN ANY DIRECTIONFROM 0% TO 4% SLOPE
UNI-INSERT™ - 3/4” & 1-1/2”SCREW ADJUSTMENT FROM 3/4” TO 1-1/2”OF ADDITIONAL HEIGHT
UNI-COLLAR™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE
UNI-BASE™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE OR CAN BE USED WITHUNI-INSERT
BUFFER PADUSED UNDER BASE TO PROVIDESLIP RESISTANCE, NOISE DAMPENING& MEMBRANE PROTECTION
4”ø SDR35 PVC PIPE USER SUPPLIED & CUTTO REQUIRED HEIGHT
COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 2-1/4” TO 22” & SLOPE ADJUSTMENT FROM 0% TO 4%
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 6
UNI-JUST™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS 1/2” to 22” HIGH & 0%-8% SLOPE
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
3. Cut PVC pipe to required height with a 12” chop saw. Using sand paper remove any burrs from cut ends.
5. Complete assemble by rotating & aligning Uni-Cap™ with Uni-Insert™. Align & attach Buffer Pad to Uni-Base.
9. Use Allen Key to fine tune loaded pedestal for a perfect level & height.
1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.
8. Use a spirit level to level Uni-Cap in any direction.
Level
Final project grade
Laser line
Deck
7. Adjust final pedestal height by using Allen Key from top to screw up or down Uni-Insert™.
Final project grade
Laser lineAllen Key
Deck
4. Assemble by inserting cut PVC pipe in to Uni-Base™ and Uni-Collar™ in to other end of PVC pipe. Screw Uni-Insert™ in to Uni-Collar™ minimum of 2 threads.
4“ø SDR35 P
VC
6. Position pedestal under laser line and align Buffer Pad notch with chalk line.
Laser line
Notch
Chalk line
2. Using a laser determine final height of pedestals. Deduct ¼” for base & cap assembly. Measure & mark PVC pipe to be cut.
4“ø SDR35 P
VC
4“ø SDR35 P
VC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 7
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
UNI-SHIM™ APPLICATION1/8” & 1/16” RIGID SHIMS USED ON TOP AND UNDER PEDESTAL
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
A UNI-SHIM 1/8” OR 1/16” MAY BE PLACED ON TOP OF EACH PEDESTAL. UNIQUE INTERLOCKING FEATURE ALLOWS SHIMS LOCK TO EACH OTHER AND TO PEDESTAL TOPS, NO GLUING REQUIRED. SHIMS MAY BE USED WHOLE OR BROKEN INTO SEGMENTS FOR FINE TUNING & LEVELING.
UNI-SHIM™ 1/8” & 1/16”
UNI-SHIMS MAY BE PLACED ON TOP OF PEDESTALS FOR MINOR LEVELING OF PAVERS WITH THICKNESS VARIATIONS. USE NO MORE THAN 3 SHIMS STACKED PER CORNER.
UNI-SHIM™ TOP OF PEDESTAL
UNI-SHIM™ UNDER PEDESTAL
MAY BE CUT INTO SEGMENTS
ADHERE W/ POLYURE-THANE CONSTRUCTION
ADHESIVE DO NOT ADHERE TO SUBSTRATE
4“ø SDR35 P
VC
4“ø SDR35 P
VC
4“ø SDR35 P
VC
PLACE UNI-SHIMS, WHOLE OR IN SEGMENTS, UNDER EACH PEDESTAL IN A STAIR STEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE NO MORE THAN 2 SHIMS, AND ADHERE THEM TO EACH OTHER WITH CONSTRUCTION ADHESIVE.
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 9
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 10
STAK-CAP™ & UNI-JUST™ PEDESTALS
COMPENSATION FROM 1/2” TO 22” HIGH & 0% TO 4% SLOPE
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
SPACERFIXED HEIGHT 1/8”
STAK-CAP™HEIGHT 3/8” SLOPE 1% Max
STAK-CAP™ X2HEIGHT 1” SLOPE 2% Max
STAK-CAP™ X3HEIGHT 1-3/8” SLOPE 3% Max
STAK-CAP™ X4HEIGHT 1-7/8” SLOPE 4% Max
STAK-CAP™ X5HEIGHT 2-1/4” SLOPE 5% Max
UNI-JUST™ w/ PVC PIPE HEIGHT 3” TO 3-3/4”SLOPE 0% TO 4%
UNI-JUST™ w/ PVC PIPE HEIGHT “VARIABLE” MAX 22”SLOPE 0% TO 4%
4“ø SDR35 P
VC
4“ø SDR35 P
VC
SAMPLE PEDESTAL CONFIGURATION & COMBINATION
UNI-JUST™ w/o PVC PIPEHEIGHT 2-1/4” TO 3” SLOPE 0% TO 4%
4“ø SDR35 P
VC
STAK-CAP™ X2 w/ PVC PIPEHEIGHT “VARIABLE” MAX 12”SLOPE 5% MAX w/ SHIMS
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
SAMPLE DECK LAYOUTOVERVIEW OF PEDESTAL PLACEMENT
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
DOOR THRESHOLD PEDESTAL PLACEMENT
RADIUS PERIMETER PEDESTAL PLACEMENT
CORNER PERIMETER PEDESTAL PLACEMENT
DIAGONAL PERIMETER PEDESTAL PLACEMENT
LOW THRESHOLD PEDESTAL PLACEMENT
ROOF DRAIN PEDESTAL PLACEMENT
LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN
LPHPSLOPE 1/4” PERFOOTRD LP RD
HP
SEE ENLARGED SECTION PLANS:
A1
B1
C1
D1
E1
F1
A1
B1
C1
D1
E1
F1
1
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 11
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
SAMPLE INITIAL INSTALLATIONUSING “T” SHAPED PATTERN
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN
REMOVE SPACER TABSFROM PERIMETER
PEDESTALS AS NECESSARY
START PAVER AND PEDESTALINSTALLATION IN “T” SHAPED
PATTERN
START PAVER AND PEDESTALINSTALLATION FROM HIGH
POINT OR THRESHOLDUSING WHOLE PAVER
MAXIMUM 1/8” GAPAT PERIMETER
LP
HP
DETERMINE CAVITY HEIGHT AT ALL THRESHOLDS, DRAINS AND HIGH POINTS. DEDUCT THE THICKNESS OF THE PAVERS FROM THE MEASURED DISTANCE BETWEEN THE TOP OF THE MEMBRANE AND THE TOP OF THE PAVERS TO DETERMINE THE PEDESTAL HEIGHT NEEDED FOR EACH LOCATION. USE A LASER LEVEL TO MARK THE TOP OF PEDESTAL ELEVATION AROUND THE DECK. PLAN PAVER & PEDESTAL LAYOUT PATTERN BEFORE STARTING, BY MARKING GUIDELINES ON THE ROOF IF NEEDED. USING THE GUIDELINES INSTALL A “T” SHAPED PORTION OF THE NEW DECK STARTING FROM THE THRESHOLD OR HIGH POINT. PAVERS ON BOTH ROWS OF THE “T” SHOULD BE ADJUSTED TO THE CORRECT HEIGHT AND LEVELED BEFORE PROCEEDING. INSTALLATION ON ALL SIDES OF THE “T” CAN THEN PROCEED AT THE SAME TIME.
2
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 12
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
BOTTOM OF THRESHOLD
THRESHOLD PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
1A
ENLARGED PLAN VIEW
THRESHOLD PEDESTAL APPLICATION - SECTION DETAILS
SLOPE DIRECTION
PERIMETER GAP1/8” MAX
VALLEY LINE
UNI-JUST™ PEDESTAL
TILE TECH PAVERS
UNI-JUST™ PEDESTAL
SDR35 PVC
PERIMETER GAP 1/8” MAX
UNI-JUST™ PEDESTALS2” TO 22” HIGH & 0%-4% SLOPE
TILE TECH PAVERS
TOP OF PAVER DECKTOP OF PEDESTAL
TOP OF WATERPROOFINGSLOPE TO DRAIN
THRESHOLD & PEDESTALHEIGHT WILL VARIE
ROOF DECK
REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL
INSULATION60psi MIN
SELF-LEVELING CAP0% TO 4% SLOPE
SLOPE
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 13
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
RADIUS PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
1B
ENLARGED PLAN VIEW
RADIUS PEDESTAL APPLICATION - SECTION DETAILS
ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL
WITH SILICONE ADHESIVE
UNI-JUST™ PEDESTALADJUSTABLE 1/2” TO 22” HIGH
TILE TECH PAVERS
TOP OF PAVER DECKTOP OF PEDESTAL
TOP OF WATERPROOFINGSLOPE TO DRAIN
ROOF DECK
REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL
INSULATION60psi MIN
SELF-LEVELING CAP0% TO 4% SLOPE
TILE TECH PAVERS
UNI-JUST™ PEDESTAL
PERIMETER GAP1/8” MAX
REMOVE EXTRA TABS ONPERIMETER PEDESTAL
TO SUPPORT PAVER EDGES
RE-INSERT REMOVED TABS& ADHERE WITH SILICONE
ADHERE EDGE CUT PAVERSTO PEDESTAL TOP
WITH SILICONE ADHESIVE
PERIMETER GAP1/8” MAX
SLOPE
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 14
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
CORNER PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
1C
ENLARGED PLAN VIEW
CORNER PEDESTAL APPLICATION - SECTION DETAILS
ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL
WITH SILICONE ADHESIVE
UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 22” HIGH
TILE TECH PAVERS
TOP OF PAVER DECKTOP OF PEDESTAL
TOP OF WATERPROOFINGSLOPE TO DRAIN
ROOF DECK
REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS
INSULATION60psi MIN
SELF-LEVELING CAP0% TO 4% SLOPE
TILE TECH PAVERS
UNI-JUST™ PEDESTAL
PERIMETER GAP1/8” MAX
REMOVE EXTRA TABS ONPERIMETER PEDESTALS
TO SUPPORT PAVER EDGES
RE-INSERT REMOVED TABS& ADHERE WITH SILICONE
ADHERE EDGE CUT PAVERSTO PEDESTAL TOP
WITH SILICONE ADHESIVE
PERIMETER GAP1/8” MAX
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 15
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
DIAGONAL PERIMETER APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
1D
ENLARGED PLAN VIEW
DIAGONAL PEDESTAL APPLICATION - SECTION DETAILS
ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL
WITH SILICONE ADHESIVE
UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 22” HIGH
TILE TECH PAVERS
TOP OF PAVER DECKTOP OF PEDESTAL
TOP OF WATERPROOFINGSLOPE TO DRAIN
ROOF DECK
REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS
INSULATION60psi MIN
SELF-LEVELING CAP0% TO 4% SLOPE
TILE TECH PAVERS
UNI-JUST™ PEDESTAL
PERIMETER GAP1/8” MAX
REMOVE EXTRA TABS ONPERIMETER PEDESTALS
TO SUPPORT PAVER EDGES
RE-INSERT REMOVED TABS& ADHERE WITH SILICONE
ADHERE EDGE CUT PAVERSTO PEDESTAL TOP
WITH SILICONE ADHESIVE
PERIMETER GAP1/8” MAX
SLOPE
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 16
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
LOW HEIGHT PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM
1E
ENLARGED PLAN VIEW
LOW HEIGHT PEDESTAL APPLICATION - SECTION DETAILS
TILE TECH PAVERS
STAK-CAP™ PEDESTAL
PERIMETER GAP1/8” MAX
REMOVE EXTRA TABSON PERIMETER PEDESTALSTO SUPPORT PAVER EDGES
STAK-CAP™ (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE
TILE TECH PAVERS
INSULATION60psi MIN
RE-INSERT REMOVED TABS& ADHERE WITH SILICONE
REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS
TOP OF PAVER DECKTOP OF PEDESTAL
TOP OF WATERPROOFING
PERIMETER GAP 1/8” MAX
SLOPE TO DRAINROOF DECK
B1
B1
STACK & ROTATE PEDESTALCAPS TO ADD HEIGHT AND CHANGE SLOPE
STACKABLE CAPS (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE
SLOPE
USE UNI-SHIM™ ON TOPOR UNDER PEDESTAL FOR
FINE HEIGHT & SLOPE ADJ.
HP
USE UNI-SHIM™ FORFINE TUNING OF INDIVIDUAL PAVERS
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 17
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
DRAIN PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
1E
ENLARGED PLAN VIEW
DRAIN PEDESTAL APPLICATION - SECTION DETAILS
TILE TECH PAVERS
A1
USE UNI-SHIMS™ ON TOPOR UNDER PEDESTAL FOR
FINE HEIGHT & SLOPE ADJ.
4“ø SDR35 P
VC
4“ø SDR35 P
VC
4“ø SDR35 PVC
4“ø SDR35 PVC
4“ø SDR35 PVC 4“ø SDR35 PVC
SLOPE TO DRAIN SLOPE TO DRAIN
STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH0% TO 5% SLOPE5 UNITS MAX
UNI-JUST™ PEDESTALSADJUSTABLE HEIGHT2-1/4” TO 22”0% TO 4% SLOPE
OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL
ROOF DRAINS
OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL UNI-JUST™ PEDESTALS
2-1/4” TO 22” HIGH
TILE TECH PAVERS
CLAULKING
METAL COUNTERFLASHING
WATERPROOF MEMBRANE
STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH
ROOF DECK
ROOF DRAIN60psi MIN INSULATION
A1
ROOF WALL JUNCTURE
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 18
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
PERIMETER EDGE RESTRAINT OPTIONSMETAL FLASHING AND WOOD FASCIA CONTAINMENT DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
LEDGER BOARD
FASCIA BOARD FLUSH WITHTOP OF PAVER
ROOF DECK
4“ø SDR35 P
VC
METAL FLASHING CONTAINMENT
WOOD FASCIA CONTAINMENT
ROOF DECK
4“ø SDR35 P
VC
TILE TECH PAVERS
DECK SCREWS
FASCIA BOARD MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF FASCIA BOARD CAN BE CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.
METAL FLASHING MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF METAL FLASHING CAN BE BENT OR CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.
LEDGER BOARD
TWO PIECE EDGE METAL
TILE TECH PAVERS
DECK SCREWS
PRE-FINISH METAL22GA. GALV.
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 19
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
PERIMETER EDGE RESTRAINT OPTIONSSTEP-DOWN AND GREEN ROOF CONTAINMENT DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.
ROOF DECK
4“ø SDR35 P
VC
STEP-DOWN CONTAINMENT
GREEN ROOF CONTAINMENT
FASCIA BOARD FLUSHWITH TOP OF PAVER
ROOF DECK
4“ø SDR35 P
VC
TILE TECH PAVERSVARIABLE RISER HEIGHT
(PER CODE)
LEDGER BOARD
UNI-JUST™ PEDESTALS2-1/4” TO 22” HIGH
ENGINEERED GREENROOF SOIL
FILTER FABRIC
L-CHANNEL WITHDRAIN HOLES
TILE TECH PAVERS
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 20
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
STEP-DOWN PEDESTAL APPLICATIONSTEP-DOWN PEDESTAL APPLICATION SECTION DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
2
TILE TECH PAVERS
ROOF DECK
UNI-JUST™ PEDESTALS2-1/4” TO 22” HIGH
LEDGER BOARD
FASCIA BOARD FLUSH WITHTOP OF PAVERS
VARIABLE RISER HEIGHT(PER CODE)
LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.
4“ø SDR35 P
VC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 21
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
WOOD TILE & PEDESTAL APPLICATIONTRANSITION, ALIGNMENT & LOCK DOWN DETAILS
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
IPE WOOD & PAVER TRANSITION AND ALLIGNMENT
TILE TECH PAVERS™
UNI-SHIM™ USED FOR INDIVIDUAL
WOOD / PAVER ALIGNMENT
TILE TECH IPE™ WOOD
4“ø SDR35 P
VC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 22
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
DECK SCREW
LOCK WASHER
INSERT THE LOCK WASHER IN TO THE KURF CUT BETWEEN THE UPPER SLAT AND BOTTOM RAIL OF 3 WOOD PAVERS. INSERT THE 4th PAVER IN TO THE 4TH CORNER. ONCE ALL 4 PAVERS ARE TIGHTLY IN PLACE INSERT SCREW THROUGH LOCK WASHER AND HAND TIGHTEN IN TO PEDESTAL TOP UNTIL ALL 4 PAVERS ARE SECURELY FASTENED TO THE PEDESTAL. DO NOT OVER TIGHTEN.
.
IPE WOOD TILES DETAILS20” x 20” x 1-1/2”
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 23
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
CROSS MEMBERTOP VIEW
IPE WOOD TILES DETAILS24” x 24” x 1-5/8”
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 24
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
CROSS MEMBERTOP VIEW
JOIST DECK & PEDESTAL APPLICATIONJOIST DECK INSTALLATION DETAILS & SPANNING CHART
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
NOTE:THIS DIAGRAM AND CHART ARE FOR CONVENIENCE ONLY. COMPATIBILITY OF DECKING MATERIAL AND JOIST SPANNING WILL VARY DEPENDING ON THE TYPE / SIZE OF CONCRETE PAVERS, WOOD OR COMPOSITE MATERIALS BEING USED. ADDITIONALLY CODE REQUIREMENTS VARY PER LOCATION AND IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE DECK MEETS CODE REQUIREMENTS.
2x8
2x10
12" O.C. JOIST SPACING
JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING
2x6 10' - 0" 4x6 OR (2) 2x6 24" O.C.
13' - 2" 4x8 OR (2) 2x8 24" O.C.
16' - 10" 4X10 OR (2) 2x10 24" O.C.
16" O.C. JOIST SPACING
JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING
2x6 9' - 1" 4x6 OR (2) 2x6 24" O.C.
2x8 12' - 0" 4x8 OR (2) 2x8 24" O.C.
2x10 15' - 2" 4X10 OR (2) 2x10 24" O.C.
20" O.C. JOIST SPACING
JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING
2x6 7' - 11" 4x6 OR (2) 2x6 24" O.C.
2x8 10' - 2" 4x8 OR (2) 2x8 24" O.C.
2x10 12' - 5" 4X10 OR (2) 2x10 24" O.C.
JOIST SPAN
TILE TECH PAVERS
UNI-SHIM™
JOIST PLATE
PEDESTAL SPACING
UNI-JUST™ PEDESTALWITH JOIST CAP
JOIST HANGER
JOIST SPACING
BEAM SIZE1-4x OR 2-2x
DECK PLANKS
JOIST
JOIST HANGER
4“ø SDR35 PVC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 25
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
WIND-LOC™ PAVER & PEDESTAL APPLICATIONPAVER LOCK DOWN SYSTEM DETAILS. PLAN AND PROFILE VIEW
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
WIND-LOC™ - PROFILE VIEW
WIND-LOC™ PEDESTAL IS MADE OF HIGH IMPACT POLYPRO-PYLENE & ABS AND IS MADE TO LOCK THE PAVER SYSTEM TOGETHER AND PREVENT WIND UPLIFT. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON GRID LINES. SET THE WIND-LOC™ BASE ON TOP OF THE PEDESTAL SYSTEM AND SET WIND-LOC™ PAVERS ON TO WIND-LOC™ BASE. BE SURE TO ALIGN RECESS ON BACK SIDE OF PAVER WITH THE DOMES ON THE WIND-LOC™ BASE. POSITION & ALIGN WIND-LOC™ PLATE ON TO WIND-LOC™ PAVERS IN A DIAMOND CONFIGU-RATION. INSTALL WIND-LOC™ SCREW IN TO WIND-LOC™ BASE WITH A HEX BIT. TIGHTEN DOWN TO 80 PSI. DO NOT OVER TIGHTEN.
WIND-LOC™ PLATE
WIND-LOC™ SCREW
WIND-LOC™ BASE
WIND-LOC™ PAVERS
WIND-LOC™ PAVERSWIND-LOC™ SCREW
WIND-LOC™ PLATE
WIND-LOC™ BASE
UNI-JUST™ PEDESTAL
4“ø SDR35 PVC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 26
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
Patent Pending
Pat. # 8,453,391 & Pat. Pen
HEX-TRAY™ SNOW MELT SYSTEMPAVER SNOW MELT SYSTEM DETAILS. PLAN AND PROFILE VIEW
GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com
HEX-TRAY™ SNOW MELT - PROFILE VIEW
HEAT TRANSFER PLATE
TILE TECH PAVERS
FOAM INSULATION
Hex-Tray™ Snow Melt System
4“ø SDR35 PVC
COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 27
National Distribution
Paving America one step at a time!Tile Tech Pavers®
Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575
HEX-TRAY™
PEX TUBING CHANNELS
4“ø SDR35 PVC
PEX TUBINGCHANNELS
TILE TECH PAVERS
FOAM INSULATION
HEX-TRAY™
HYBRID PEDESTAL SYSTEM
HEAT TRANSFER PLATE
Patent Pending
Pat. # 8,453,391 & Pat. Pen
PEX TUBING
HEX-TRAY™ SNOW MELT SYSTEM COMPONENTS INCLUDES A HONEYCOMB STRUCTURAL TRAY WITH PEX TUBING CHANNELS, A FOAM INSULATION PANEL, ALUMINUM HEAT TRANSFER PLATE AND USER SUPPLIED ½“ PEX TUBING. PRE ASSEMBLE THE FOAM INSULATION PANEL TO THE BACK OR BOTTOM SIDE OF THE HEX-TRAY AND SECURE WITH SUPPLIED CORK-SCREW. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON TO GRID LINES. PLACE SEMI ASSEMBLED HEX-TRAY™ ON TO PEDESTAL SYSTEM. LEVEL & SECURE FOUR ADJACENT CORNERS TO PEDESTAL SYSTEM USING PERFORATED LOCK DISK AND SECURE WITH SCREW. POSITION AND ALIGN HEAT TRANSFER PLATE TO TOP OF HEX-TRAY™. AT TERMINATION POINTS AND WALLS, CUT BACK HEAT TRANSFER PLATE TO EXPOSE THE “U” SHAPED CHANNELS IN ORDER TO LOOP BACK PEX TUBING. INSTALL PEX TUBING AND TEST FOR LEAKS. INSTALL PAVERS.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 1 of 7
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
and Division 01 Specification Sections, apply to this Section. 1.2 Summary
A. Furnish and install a complete Architectural Pavers and Adjustable Pedestals deck support system with a maximum cavity height of up to 22 inches.
B. Related Sections include the following: 1. Division 02 - Section 02780 Unit Pavers
2. Division 03 - Section 03300 Cast-in-Place Concrete. 3. Division 06 - Section 06100 Rough Carpentry. 4. Division 07 - Section 07760 Roof Pavers. 5. Division 07 - Section 07620 Roof related Metal Work. 6. Division 07 - Section 07540 Fluid Applied Waterproofing. 7. Division 07 - Section 07540 Bituminous Sheet Waterproofing. 8. Division 07 - Section 07760 Roof Pavers.
1.3 REFERENCES A. American Society for Testing and Materials (ASTM) 1. ASTM D 638 - Tensile Properties of Plastics 2. ASTM D 790 - Flexural Properties of Unreinforced and Reinforced Plastics Insulating 3. ASTM D 1525 -Vicat Softening Temperature of Plastics 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Samples:
1. Architectural Pavers: Submit samples for type, color and texture required. 2. Pedestals: Submit sample of each pedestal component. 3. PVC Pipe: Submit 12-inch long sample of PVC pipe.
B. Shop Drawings: Submitted by contractor showing all components required for the paver & pedestal
requirements. Shop drawings shall include plan drawings showing layout of all paver areas and detail drawings showing how the various components of the system fit together. Include manufacturer’s literature completely describing all components of the paver pedestal systems and giving detailed installation recommendations and instructions. Also included detailed installation drawings for all precast pavers.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: All products covered under this Section shall be produced by a single manufacturer unless otherwise specified with a minimum of fifteen (15) years proven production experience.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 2 of 7
B. Installer Qualifications: Installer shall have a minimum of three (3) years proven construction experience
and be capable of estimating & building from blueprint plans and details, determining elevations, in addition to proper material handling. All Work must comply with Tile Tech Pavers installation application procedures for pedestal mounted pavers as specified herein.
C. Special Consideration: The installer and or subcontractor must assume the responsibility for and take
into consideration (1) the structural capability and adequacy of the structure to carry the dead and live load weight(s) involved, and (2) that the density of any insulation is satisfactory to resist crushing and damaging the waterproofing membrane.
1.6 DELIVERY, STORAGE, AND HANDLING A. In accordance with provisions of Section 01300. B. Protect Concrete Pavers and Pedestal System during shipment, storage and construction against damage.
Store a minimum of 4 inches off the ground in a dry location and cover with polyethylene to protect from contact with materials which would cause staining or discoloration.
1.7 PROJECT CONDITIONS
A. Tile Tech Pedestal System specified are to be used with pedestrian traffic only & all four (4) sides of a deck system must restrain and contain the decking panels with perimeter blocking or walls. Decking panels must not be allowed to move laterally.
B. All membrane waterproofing and protection board surfaces to receive pedestals must be broom clean, frost
free, and free of dirt, oil or any rough foreign matter, which may impair the waterproofing / roofing manufacturers guarantee or protection requirements.
C. The substrate that is to receive pedestals must have slope and provide positive and adequate drainage in
accordance with good building practice and applicable building codes. D. Decks over Roofing and Waterproofing;
1. If high density closed cell extruded 60psi polystyrene insulation is installed on top of the membrane in a protected membrane system, Tile Tech Pedestals may be installed directly on top of this type of insulation.
2. Do not use Tile Tech Pedestals over any insulation less than 60psi or with low density polystyrene (bead board) insulation.
E. Decks on Grade:
1. Any substrate soil that is to receive pedestals shall be adequately compacted and have positive drainage slope. A “walkway gravel” base ie:¼” Minus should be installed and compacted at pedestal locations.
2. A wall or perimeter containment on all open sides is required. Install structural perimeter containment that restrains the entire decking system.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 3 of 7
F. Installation or anticipated installation of additional items on top of the deck such as planters, hot tubs,
sculptures, or industrial equipment must be supported directly by additional pedestals that are in addition to the main deck paver/tile pedestal system. Failure to adequately support the additional weight of any such features or items may cause significant damage to the deck, underlying structure, or waterproofing .
1.8 WARRANTIES / GUARANTEES
A. Tile Tech Pedestal System (pavers and pedestals) shall remain free from defects for a period of ten (10) years. The contractor shall warrant that his work will remain free from defects of labor and materials used in conjunction with his work in accordance with the general conditions for this project or a maximum of three (3) years.
PART 2 – PRODUCTS 2.1 MANUFACTURERS
A. The Paver Pedestal Systems specified herein are based upon products manufactured by: Tile Tech Pavers Inc, 888-380-5575 Phone: (213) 380-5560 Fax: (213) 380-5561 E-mail: sales@tiletechpavers.com Website: www.tiletechpavers.com
B. Paver Pedestal Systems equal in appearance and function and meeting these specifications, will be
acceptable when the specified submittals are approved in writing by the Architect prior to bid. 2.2 MATERIALS A. PAVERS: 1. Type: Granite-Tech™, Stamp-Tech™, Cool-Roof™, Recycled Glass and Win-Lok™.
2. Color: Standard and custom range manufactured by Tile Tech Pavers Inc. 3. Size: 20”x20”x2”, 16”x16”x1-1/2” , 12”x12”x1” , 12”x24”x1-1/2” , 16”x24”x2” nominal 4. Finish: Shot-blasted with 3/16” bevel on all four (4) sides of finished surface. 5. Weight: 11 to 22 lbs per square foot depending on paver size & thickness.
B. PEDESTALS:
1. Stak-Cap™ Pedestals: PVC Pipe & Stack Adjustable a. Stack or use SDR35 PVC pipe to accommodate various HEIGHT adjustments of ½” to 8”. b. Each cap provides maximum of ½” of HEIGHT and 1% SLOPE. Rotate and stack one cap
relative to another to accommodate SLOPE adjustments from 0% to 5%. c. Base diameter of 6-inch and top diameter of 5-¼-inch and is ½-inch high.
d. Made of high impact and flame resistant ABS plastic. e. Use of Buffer Pads under Stak-Cap™ Pedestals is MANDATORY.
2. Uni-Just™ Pedestals: PVC Pipe & Screw Adjustable a. Assemply consist of 5 parts: Uni-Base™, Uni-Collar™, Uni-Insert™, Uni-Cap™ & Buffer
Pads. b. Use SDR35 PVC pipe to accommodate various HEIGHT adjustments from 2-½” to 22”. Additional precise height adjustment of up to 1-½” with the use of Uni-Insert™ which
can screw up or down while loaded. c. Self-leveling and can tilt in any direction to a level plane to accommodate SLOPE
adjustments from 0% to 6%.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 4 of 7
d. Base diameter of 7-inch with bearing surface area of thirty eight (38) square inches. e. Made of 100% recycled and flame resistant High Density Polypropylene. f. Use of Buffer Pads under Uni-Just™ Pedestals is MANDATORY.
3. Uni-Shims™: 1/8-inch & 1/16-inch Thick
a. Can be used whole or broken into halves or quarters and can be stacked up to 2 high. b. Used on top or under Stak-Cap™ or Uni-Just™ Pedestals for fine leveling of pedestals and
or individual pavers. c. Made of high impact and flame resistant ABS plastic.
C. OTHER COMPONENTS: INSTALLER OR USER SUPPLIED 1. Pedestal Pipe: 4-inch diameter SDR35 PVC Sewer Pipe
a. Used with either Stak-Cap™ or Uni-Just™ Pedestals and is cut to required height. b. Dimensions: 4.215-inch outside diameter & 3.890-inch inside diameter. c. Meet ASTM D-3034 and F-679.
b. NOT supplied with pedestal components by Tile Tech Pavers. 2. Protection Course:
a. Protection board (required over insulated BUR systems, and when specified for use over bituminous asphalt-based waterproofing): W.R. Meadows “Vibraflex” or equal, minimum 3/8- inch thick asphaltic composition protection board.
b. Insulation (when specified): Dow Styrofoam “Highload 100” or equal, minimum compressive strength of 100psi recommended for foam plastic insulation placed beneath Pedestal System to prevent damage to the waterproofing membrane.
c. NOT supplied with pedestal components by Tile Tech Pavers. 2.3 PERIMETER CONTAINMENT AND SUPPORT
A. The complete assembly of insulation (if used), protection board (if used), drainage mat (if used), pedestals and pavers must be restrained at the perimeter of the deck area.
B. Perimeter parapet walls, concrete dividers or other perimeter restraint must be capable of resisting lateral
forces (including seismic and wind). Cumulative movement in excess of 1/8 inch will void the Tile Tech Pavers Pedestal System warranty.
PART 3 – EXECUTION 3.1 EXAMINATION
A. Prior to starting work inspect the substrate to ensure that it has been properly prepared to accept the Tile Tech Pedestal System. The substrate and or surface shall be clean and free of any projections and debris which may impair the performance of the pedestal and or the deck system. Verify all elevations, required pedestal heights and deck dimensions. Commencement of work shall imply acceptance of surfaces & deck conditions.
B. If preparation is the responsibility of another installer, notify Architect in writing of deviations from
manufacturer's recommended installation tolerances and conditions.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 5 of 7
3.2 PREPARATION
A. The substrate surface that will receive the Pedestal System must be well compacted (on Grade) or structurally capable of carrying the dead and live loads anticipated. 1. Insulation OVER the membrane: (Option 1) Insulation and/or protection board (if specified) must
be applied over the waterproofing substrate and/or specified drainage mat. Install the system according to the membrane manufacturer’s recommendations and specifications.
2. Insulation UNDER membrane: (Option 2) Insulation required to be installed within a roofing system below deck supports must meet the roofing membrane manufacturers’ specifications and must have a minimum core density of 60psi.
3. Protection Board: (for asphalt type systems used over waterproofing) Full coverage 1/8-inch asphaltic composition protection board is recommended. When protection is specified only under the pedestal cut protection board pads to extend beyond the outside perimeter of the pedestal system base or buffer pad by a minimum of TWO (2) inch.
4. Drainage Mat: (when desired or specified) Install drainage mat according to the manufacturers recommendations to avoid crushing.
3.3 INSTALLATION
A. Install in accordance with Tile Tech Pavers and other contributing manufacturer's instructions. Installation requirements vary for each individual project site. Decking paver or tile used, pattern, grid layout, starting point, and finished elevation should be shown on plan view shop drawings, which have been prepared and approved by the designer, installing contractor and/or owner.
B. GRID LAYOUT AND ELEVATIONS: 1. Once the starting point and the finished elevation of the deck surface have been determined, the
“Top of Pedestal Elevation” (finished elevation less decking paver or tile thickness) is established and marked around the perimeter using a transit water level or laser leveling device.
2. Precise measurements should be taken and deck area should be accurately defined. Mark off and
‘square up’ all outside edges with control lines using "snapped" chalk lines. Mark two (2) lines that are perpendicular to each other across the deck area. Continue to mark a grid of lines in both directions marking the location of each pedestal. Use the control lines as references to periodically check and assure a square layout during installation.
3. Next, a pedestal must be placed where each measured grid line meets the perimeter. Remove two (2) spacer tabs in line with one another atop each pedestal system placed around the perimeter. Remove all four (4) spacer tabs at corners.
4. Adjust each pedestal height to the “Top of Pedestal Elevation” marked on the perimeter. Position
the pedestal as close to the edge of the perimeter as possible, with the two remaining spacer tabs aligned with the grid line. Using the elevation marked on the perimeter, stretch a mason’s line along and slightly ahead of the second row of pedestals. A laser leveling device may also be used for this purpose.
5. On larger decks, it is recommended that Tile Tech Pedestal System be pre-assembled and pre-set
to the proper elevation and placed in position prior to the installation of decking paver or tile.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 6 of 7
6. As the pedestals located along the grid lines are loaded with pavers or tiles, fine vertical height
adjustment can be made by inserting and rotating, from the top, a T-handle Hex Key in to the Uni-Insert™ of the Pedestal assembly. Clockwise rotation of the Uni-Insert™ will raise the bearing surface and the deck. Counter-clockwise rotation will lower the top bearing surface and deck.
7. Always maintain adequate thread engagement. Tile Tech Pedestal Uni-Insert™ contains a locking tab that will not allow the screw to extend past its maximum extension. Never use if the
locking tab is broken. If the height required goes beyond the Uni-Insert™ limit re-cut PVC pipe to the correct height and re-assemble the pedestal using the correct size pipe.
8. Slight irregularities in decking paver or tile thickness can be compensated for by using one (1) to
two (2) shim segments. Place on top of the pedestal, under the corner(s) of the decking paver or tile. Use no more than two (2) shims on top of the pedestal and always adhere quartered (1/4) wedges with construction adhesive.
9. Stak-Cap™ Pedestal can be used for limited and or fixed height requirements. Complete deck and
grid layout as instructed above. Stack no more than five (5) fixed height Stak-Cap™ Pedestals together and place in lieu of Uni-Just™ Pedestals where needed. Stak-Cap™ Pedestal can also be used with PVC pipe to reduce cost. Spacer tabs can be removed to accommodate perimeter and corner support locations.
C. SLOPE AND HEIGHT COMPENSATION:
1. Stak-Cap™ Pedestals can provide limited slope and height compensation to maintain a level decking surface over sloping substrates and is accomplished using a combination of the following: a. Rotate and stack one cap in relation to another to change slope and add height. Each cap
will add ½-inch of height and provide 1% slope. Stack no more than 5 caps. b. Can also be used with PVC Pipe cut to required height of maximum of 6-inches.
2. Uni-Just™ Pedestals can provide both slope and height compensation to maintain a level decking surface over sloping substrates and is accomplished using a combination of the following:
a. PVC Pipe cut to varying lengths to compensate for GENERAL height requirements. b. SCREW extension for PRECISE height adjustment.
c. Self-Leveling cap that pivots and tilts in any direction for slope compensation from 0% to 6%.
3. Tile Tech Pedestals are designed to be rotated for final precise adjustment when they are fully
loaded. Pedestals should be leveled in each succeeding row as the installation proceeds. Final height adjustment or maintenance is easily made by simply using a T-handle Hex Key that allows you to adjust the pedestals without removing the pavers. T-handle Hex Key is inserted between the four paver corners to engage Uni-Insert™ portion and is adjusted clockwise or counter clockwise to level as needed.
4. Uni-Shims™ may be used in multiples, whole or quarters, and placed under the pedestal base or
on top the pedestal cap to level pedestals. Use a small amount of construction adhesive to adhere sections of shims and/or whole shims to each other or to the pedestal. DO NOT use construction adhesive to adhere pedestal or shims to insulation, roofing or waterproofing membrane. Additional sections of shims may be used and should be available for regular maintenance.
SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM
© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 7 of 7
3.4 PERIMETER CONTAINMENT
A. Any area of the pedestal deck that is not restrained by a parapet or foundation wall must be ‘boxed-in’ and contained. The deck panels will move if all sides are not adequately restrained. Perimeter framing and
edging boards located at the outside of the deck perimeter must be installed to provide restraint. No movement should be allowed at the perimeter of the deck system greater than one tab width.
3.5 FIELD QUALITY CONTROL
A. Inspect often during installation to assure that grid spacer lines are being maintained in a straight and consistent pattern and that deck pavers or tiles are level and not rocking. Unless otherwise specified in writing to allow for expansion, inspect to assure that all paver spacing between tiles and at perimeter walls does not exceed a tab width. Particular attention should be made to assure that all pedestrian entry or access points to the deck are level and that the deck surface tiles are not randomly raised or uneven creating a tripping or safety hazard. Confirm that deck pedestal height excess of sixteen (16) inches have been braced in accordance with Tile Tech Pavers written instructions.
3.6 ROUTINE MAINTENANCE AND CARE
A. The deck owner must perform routine maintenance of the deck. Check for rocking pavers and adjust using T-Handle Hex Key or shim immediately. Pedestals can settle and may have to be realigned. Failure to do so can cause a tripping hazard. Periodically check spacer tabs and immediately replace broken tabs to limit deck movement. Make sure the edge restraint stays intact and structurally sound.
B. Extra Materials: Deliver supply of maintenance materials to the owner. Furnish not less than 1 percent
maintenance materials from same lot as materials installed, and enclosed in protective packaging with appropriate identifying labels.
END OF SECTION 07760 ROOF PAVERS AND PEDESTALS
Visit our website at www.tiletechpavers.com
for complete design details and photo gallery
Paving America one step at a time!Tile Tech Pavers®
©1996-2013 Tile Tech Pavers
HP-D 01/14
MADE IN AMERICA
888-380-5575 213-380-5561 Sales@tiletechpavers.com www.TileTechPavers.com