tile tech pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck...

34
Paving America one step at a time! Tile Tech Pavers ® Uni-Just™ & Stak-Cap™ Pedestal System Single Model Design PVC Pipe Adjustable Self-Leveling Screw Adjustable Stackable Pat. # 8,453,391 & Pat. Pen HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS

Upload: others

Post on 10-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

Paving America one step at a time!Tile Tech Pavers®

Uni-Just™ & Stak-Cap™ Pedestal System

Single Model Design PVC Pipe Adjustable Self-LevelingScrew Adjustable Stackable

Pat. # 8,453,391 & Pat. Pen

HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS

Page 2: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

TILE TECH PEDESTAL SYSTEMTABLE OF CONTENTS

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 2

3. COMPONENTS LIST

7. INSTALLATION INSTRUCTIONS UNI-JUST™ PEDESTALS

5. INSTALLATION INSTRUCTIONS STAK-CAP™ PEDESTALS

4. COMPONENT ASSEMBLY INSTRUCTIONS STAK-CAP™ PEDESTALS

6. COMPONENT ASSEMBLY INSTRUCTIONS UNI-JUST™ PEDESTALS

8. BASE SLOPE COMPENSATION

9. UNI-SHIM™ APPLICATION

10. PEDESTAL COMBINATION & CONFIGURATION

11. SAMPLE DECK LAYOUT - OVERVIEW

12. SAMPLE INITIAL INSTALLATION

13. THRESHOLD PEDESTAL APPLICATION

14. RADIUS PEDESTAL APPLICATION

16. DIAGONAL PERIMETER APPLICATION

17. LOW HEIGHT PEDESTAL APPLICATION

18. DRAIN PEDESTAL APPLICATION

20. PERIMETER EDGE RESTRAINT STEP-DOWN AND GREEN ROOF CONTAINMENT

19. PERIMETER EDGE RESTRAINT METAL FLASHING AND WOOD FASCIA CONTAINMENT

21. STEP-DOWN PEDESTAL APPLICATION

22. IPE WOOD TILE APPLICATION

23. WOOD TILES 20X20 DETAILS

24. WOOD TILES 24X24 DETAILS

25. JOIST DECK PEDESTAL APPLICATION

26. WIN-LOC™ PAVER PAVER LOCK DOWN SYSTEM FOR WIND UPLIFT.

27. HEX-TRAY™ PAVER SNOW MELT SYSTEM.

15. CORNER PEDESTAL APPLICATION

Page 3: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

TILE TECH PEDESTAL SYSTEMCOMPLETE PRODUCT LINE & COMPONENTS LIST

MODEL NUMBER DESCRIPTIONPRODUCT LINE

SPACERS 1/8” & 1/4”

UNI-SHIM™ - 1/8” & 1/16”

ALLOW FOR 1/8” SPACING GAP BETWEEN PAVERS FOR DRAINAGE. TABS A PERFORATED FOR EASY REMOVAL.

USED FOR FINE TUNING OF INDIVIDUAL PAVERS. CAN BE USED ON TOP OR BOTTOM OF PEDESTALS. CAN BE STACKED & BROKEN IN TO QUARTERS OR HALVES.

UNI-INSERT™ -75 (3/4”)USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 3/4” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.

BUFFER PAD

PROVIDES PROTECTION TO WATERPROOFING MEM-BRANE FROM WEAR AND PROVIDES SLIP RESISTANCE TO PEDESTAL. ATTACHES TO BOTTOM OF BASE. ALIGN PERIMETER NOTCHES WITH CHALK LINES.

UNI-COLLAR™

USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL SYSTEM. COMPRESSION FITS ON TO TOP END OF PVC PIPE.

SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE. ALIGN & LOCK TO UNI-INSERT™.

UNI-CAP™

STAK-CAP™USED OF LOW HEIGHT REQUIREMENTS. ROTATE AND STACK CAPS FOR SLOPE & HEIGHT ADJUSTMENT. CAN ALSO BE USED WITH PVC PIPE TO REACH 12” MAX.

UNI-BASE™

USED AS BASE OF PEDESTAL SYSTEM. COMPRESSION FITS ON TO END OF PVC PIPE. CAN ALSO BE USED WITH UNI-INSERT™ FOR LOW HEIGHT APPLICATIONS. LARGE SURFACE AREA PROVIDE ADDED STABILITY.

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

UNI-INSERT™ -150 (1-1/2”)

USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 1-1/2” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 3

USED FOR SLOPE COMPENSATION AT BASE OF PEDESTALS. EACH PLATE COMPENSATES FOR 1/4” PER FOOT (2%) SLOPE AND ADDS 3/8” TO THE OVERALL HEIGHT OF PEDESTAL. MAXIMUM OF FOUR PLATES MAY BE STACKED FOR COMPEN-SATION OF UP TO 1” PER FOOT (0-8%) SLOPE.

BASE SLOPE PLATE (BSP)

Page 4: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

STAK-CAP™ PEDESTAL SYSTEM

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

CONFIGURATION CHART:1 CAP = 5/8” HIGH 1/8” PER FOOT 1% MAX2 CAPS = 1” HIGH 1/4” PER FOOT 2% MAX (A+A)3 CAPS = 1-3/8” HIGH 3/8” PER FOOT 3% MAX (A+A+A)4 CAPS = 1-7/8” HIGH 1/2” PER FOOT 4% MAX (A+A+A+A)5 CAPS = 2-1/4“ HIGH 5/8” PER FOOT 5% MAX (A+A+A+A+A)

PVC + 2 CAPS = VARIABLE HEIGHT 0% MAXPVC + 3 CAPS = VARIABLE HEIGHT 1% MAXPVC + 4 CAPS = VARIABLE HEIGHT 2% MAXPVC + 5 CAPS = VARIABLE HEIGHT 3% MAX

COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 1/2” TO 12” & SLOPE ADJUSTMENT FROM 0% TO 5%

PRODUCT CHARACTERISTICS:EACH CAP WILL COMPENSATE FOR UP TO 1/8” PER FOOT SLOPE (1%) & ADD 3/8” TO THE OVERALL HEIGHT OF A PEDESTAL. PVC PIPE CAN BE USED TO GAIN ADDITIONAL HEIGHT OF 12” MAX. ROTATE ONE CAP RELATIVE TO ANOTHER BY ALIGNING THE ALPHABETS TO CHANGE SLOPE. A & A WILL REACH MAXIMUM SLOPE AND A & E WILL CANCEL SLOPE. A MAXIMUM OF 5 CAPS CAN BE STACKED WITH TOTAL SLOPE OF 5/8” PER FOOT (5%) & WITH TOTAL HEIGHT OF 2-1/4” INCLUDING THE USE OF BUFFER PADS.

STACK

ROTATE

4“ø SDR35 P

VC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 4

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 5: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

STAK-CAP™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS - 1/2” to 12” HIGH & 0%-3% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

3. Cut PVC pipe to required height with a 12” chop saw. Using sand paper remove any burrs from cut ends.

9. Use a spirit level to check level and use additional half or quarter Uni-Shims™ for fine tuning of individual corners.

1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.

8. Use a spirit level to check level and use additional half or quarter Uni-Shims™ for fine tuning of individual corners.

7. Adjust final pedestal height by using Uni-Shims™ whole or in segments at the top or bottom of pedestal assembly.

Final project grade

Laser line

2. Using a laser determine final height of pedestals. From ½” to 1-½” high no PVC pipe required. Measure & mark PVC pipe to be cut & deduct ¼” for base & cap assembly.

4“ø SDR35 P

VC

4“ø SDR35 P

VC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 5

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

4. Assemble by inserting Stak-Cap™ on to one end of cut PVC pipe and another Stak-Cap™ on to other end of PVC pipe. The Stak-Cap™ is designed to compres-sion fit with PVC pipe.

4“ø SDR35 P

VC

5. Complete assemble by rotating & aligning alphabets of 3rd Stak-Cap™ with the top Stak-Cap™ for slope compensa-tion. Align & attach Buffer Pad to the bottom Stak-Cap™.

Laser line

6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Orient the pedestal assembly so that the top Stak-Cap™ pair high side points towards decline of slope.

NotchChalk line

Deck

4“ø SDR35 P

VC

Level

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SD

R35 P

VC

Leveling Shims

Level

STACK

ROTATE

Page 6: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

UNI-JUST™ PEDESTAL SYSTEM

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

PRODUCT CHARACTERISTICS:ADJUSTABLE HEIGHT FROM 2-1/4” TO 22” WITH USE OF 4”ø SDR35 PVC PIPE.SELF-LEVELING CAP AUTOMATICALLY ADJUST SLOPE FROM 0% TO 4%.SCREW ADJUSTABLE WHILE PEDESTALS ARE LOADED FOR FINAL HEIGHT ADJUSTMENT OF 1-1/2”RESISTANT & IMPERVIOUS TO FREEZE-THAW, WATER, MOLD, ACID & ULTRAVIOLET DETERIORATION.RESISTANT TO TEMPERATURES BETWEEN -22°F AND +250°F.LARGE FOOT PRINT SPREADS WEIGHT OVER ROOFING MEMBRANE AND SUBSTRATEBUFFER PADS PROVIDE NOISE DAMPENING, SLIP RESISTANCE AND PROTECTION TO ROOFING MEMBRANE AND SUBSTRATE.MAXIMUM DESIGN CAPACITY OF 2,OOO LBS PER PEDESTAL.

4“ø SDR35 P

VC

SPACER TABS - 1/8” TABS CAN BE BROKEN OFF ALLOW DIFFERENT PAVING CONFIGURATION

UNI-CAP™SELF-LEVELING & ADJUSTABLEIN ANY DIRECTIONFROM 0% TO 4% SLOPE

UNI-INSERT™ - 3/4” & 1-1/2”SCREW ADJUSTMENT FROM 3/4” TO 1-1/2”OF ADDITIONAL HEIGHT

UNI-COLLAR™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE

UNI-BASE™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE OR CAN BE USED WITHUNI-INSERT

BUFFER PADUSED UNDER BASE TO PROVIDESLIP RESISTANCE, NOISE DAMPENING& MEMBRANE PROTECTION

4”ø SDR35 PVC PIPE USER SUPPLIED & CUTTO REQUIRED HEIGHT

COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 2-1/4” TO 22” & SLOPE ADJUSTMENT FROM 0% TO 4%

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 6

Page 7: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

UNI-JUST™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS 1/2” to 22” HIGH & 0%-8% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

3. Cut PVC pipe to required height with a 12” chop saw. Using sand paper remove any burrs from cut ends.

5. Complete assemble by rotating & aligning Uni-Cap™ with Uni-Insert™. Align & attach Buffer Pad to Uni-Base.

9. Use Allen Key to fine tune loaded pedestal for a perfect level & height.

1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.

8. Use a spirit level to level Uni-Cap in any direction.

Level

Final project grade

Laser line

Deck

7. Adjust final pedestal height by using Allen Key from top to screw up or down Uni-Insert™.

Final project grade

Laser lineAllen Key

Deck

4. Assemble by inserting cut PVC pipe in to Uni-Base™ and Uni-Collar™ in to other end of PVC pipe. Screw Uni-Insert™ in to Uni-Collar™ minimum of 2 threads.

4“ø SDR35 P

VC

6. Position pedestal under laser line and align Buffer Pad notch with chalk line.

Laser line

Notch

Chalk line

2. Using a laser determine final height of pedestals. Deduct ¼” for base & cap assembly. Measure & mark PVC pipe to be cut.

4“ø SDR35 P

VC

4“ø SDR35 P

VC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 7

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 8: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

UNI-SHIM™ APPLICATION1/8” & 1/16” RIGID SHIMS USED ON TOP AND UNDER PEDESTAL

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

A UNI-SHIM 1/8” OR 1/16” MAY BE PLACED ON TOP OF EACH PEDESTAL. UNIQUE INTERLOCKING FEATURE ALLOWS SHIMS LOCK TO EACH OTHER AND TO PEDESTAL TOPS, NO GLUING REQUIRED. SHIMS MAY BE USED WHOLE OR BROKEN INTO SEGMENTS FOR FINE TUNING & LEVELING.

UNI-SHIM™ 1/8” & 1/16”

UNI-SHIMS MAY BE PLACED ON TOP OF PEDESTALS FOR MINOR LEVELING OF PAVERS WITH THICKNESS VARIATIONS. USE NO MORE THAN 3 SHIMS STACKED PER CORNER.

UNI-SHIM™ TOP OF PEDESTAL

UNI-SHIM™ UNDER PEDESTAL

MAY BE CUT INTO SEGMENTS

ADHERE W/ POLYURE-THANE CONSTRUCTION

ADHESIVE DO NOT ADHERE TO SUBSTRATE

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 P

VC

PLACE UNI-SHIMS, WHOLE OR IN SEGMENTS, UNDER EACH PEDESTAL IN A STAIR STEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE NO MORE THAN 2 SHIMS, AND ADHERE THEM TO EACH OTHER WITH CONSTRUCTION ADHESIVE.

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 9

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 9: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 10

STAK-CAP™ & UNI-JUST™ PEDESTALS

COMPENSATION FROM 1/2” TO 22” HIGH & 0% TO 4% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

SPACERFIXED HEIGHT 1/8”

STAK-CAP™HEIGHT 3/8” SLOPE 1% Max

STAK-CAP™ X2HEIGHT 1” SLOPE 2% Max

STAK-CAP™ X3HEIGHT 1-3/8” SLOPE 3% Max

STAK-CAP™ X4HEIGHT 1-7/8” SLOPE 4% Max

STAK-CAP™ X5HEIGHT 2-1/4” SLOPE 5% Max

UNI-JUST™ w/ PVC PIPE HEIGHT 3” TO 3-3/4”SLOPE 0% TO 4%

UNI-JUST™ w/ PVC PIPE HEIGHT “VARIABLE” MAX 22”SLOPE 0% TO 4%

4“ø SDR35 P

VC

4“ø SDR35 P

VC

SAMPLE PEDESTAL CONFIGURATION & COMBINATION

UNI-JUST™ w/o PVC PIPEHEIGHT 2-1/4” TO 3” SLOPE 0% TO 4%

4“ø SDR35 P

VC

STAK-CAP™ X2 w/ PVC PIPEHEIGHT “VARIABLE” MAX 12”SLOPE 5% MAX w/ SHIMS

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 10: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SAMPLE DECK LAYOUTOVERVIEW OF PEDESTAL PLACEMENT

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

DOOR THRESHOLD PEDESTAL PLACEMENT

RADIUS PERIMETER PEDESTAL PLACEMENT

CORNER PERIMETER PEDESTAL PLACEMENT

DIAGONAL PERIMETER PEDESTAL PLACEMENT

LOW THRESHOLD PEDESTAL PLACEMENT

ROOF DRAIN PEDESTAL PLACEMENT

LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN

LPHPSLOPE 1/4” PERFOOTRD LP RD

HP

SEE ENLARGED SECTION PLANS:

A1

B1

C1

D1

E1

F1

A1

B1

C1

D1

E1

F1

1

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 11

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 11: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SAMPLE INITIAL INSTALLATIONUSING “T” SHAPED PATTERN

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN

REMOVE SPACER TABSFROM PERIMETER

PEDESTALS AS NECESSARY

START PAVER AND PEDESTALINSTALLATION IN “T” SHAPED

PATTERN

START PAVER AND PEDESTALINSTALLATION FROM HIGH

POINT OR THRESHOLDUSING WHOLE PAVER

MAXIMUM 1/8” GAPAT PERIMETER

LP

HP

DETERMINE CAVITY HEIGHT AT ALL THRESHOLDS, DRAINS AND HIGH POINTS. DEDUCT THE THICKNESS OF THE PAVERS FROM THE MEASURED DISTANCE BETWEEN THE TOP OF THE MEMBRANE AND THE TOP OF THE PAVERS TO DETERMINE THE PEDESTAL HEIGHT NEEDED FOR EACH LOCATION. USE A LASER LEVEL TO MARK THE TOP OF PEDESTAL ELEVATION AROUND THE DECK. PLAN PAVER & PEDESTAL LAYOUT PATTERN BEFORE STARTING, BY MARKING GUIDELINES ON THE ROOF IF NEEDED. USING THE GUIDELINES INSTALL A “T” SHAPED PORTION OF THE NEW DECK STARTING FROM THE THRESHOLD OR HIGH POINT. PAVERS ON BOTH ROWS OF THE “T” SHOULD BE ADJUSTED TO THE CORRECT HEIGHT AND LEVELED BEFORE PROCEEDING. INSTALLATION ON ALL SIDES OF THE “T” CAN THEN PROCEED AT THE SAME TIME.

2

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 12

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 12: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

BOTTOM OF THRESHOLD

THRESHOLD PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1A

ENLARGED PLAN VIEW

THRESHOLD PEDESTAL APPLICATION - SECTION DETAILS

SLOPE DIRECTION

PERIMETER GAP1/8” MAX

VALLEY LINE

UNI-JUST™ PEDESTAL

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

SDR35 PVC

PERIMETER GAP 1/8” MAX

UNI-JUST™ PEDESTALS2” TO 22” HIGH & 0%-4% SLOPE

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

THRESHOLD & PEDESTALHEIGHT WILL VARIE

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

SLOPE

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 13

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 13: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

RADIUS PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1B

ENLARGED PLAN VIEW

RADIUS PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALADJUSTABLE 1/2” TO 22” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTAL

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

SLOPE

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 14

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 14: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

CORNER PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1C

ENLARGED PLAN VIEW

CORNER PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 22” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTALS

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 15

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 15: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

DIAGONAL PERIMETER APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1D

ENLARGED PLAN VIEW

DIAGONAL PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 22” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTALS

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

SLOPE

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 16

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 16: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

LOW HEIGHT PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

1E

ENLARGED PLAN VIEW

LOW HEIGHT PEDESTAL APPLICATION - SECTION DETAILS

TILE TECH PAVERS

STAK-CAP™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABSON PERIMETER PEDESTALSTO SUPPORT PAVER EDGES

STAK-CAP™ (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE

TILE TECH PAVERS

INSULATION60psi MIN

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFING

PERIMETER GAP 1/8” MAX

SLOPE TO DRAINROOF DECK

B1

B1

STACK & ROTATE PEDESTALCAPS TO ADD HEIGHT AND CHANGE SLOPE

STACKABLE CAPS (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE

SLOPE

USE UNI-SHIM™ ON TOPOR UNDER PEDESTAL FOR

FINE HEIGHT & SLOPE ADJ.

HP

USE UNI-SHIM™ FORFINE TUNING OF INDIVIDUAL PAVERS

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 17

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 17: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

DRAIN PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1E

ENLARGED PLAN VIEW

DRAIN PEDESTAL APPLICATION - SECTION DETAILS

TILE TECH PAVERS

A1

USE UNI-SHIMS™ ON TOPOR UNDER PEDESTAL FOR

FINE HEIGHT & SLOPE ADJ.

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 PVC

4“ø SDR35 PVC

4“ø SDR35 PVC 4“ø SDR35 PVC

SLOPE TO DRAIN SLOPE TO DRAIN

STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH0% TO 5% SLOPE5 UNITS MAX

UNI-JUST™ PEDESTALSADJUSTABLE HEIGHT2-1/4” TO 22”0% TO 4% SLOPE

OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL

ROOF DRAINS

OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL UNI-JUST™ PEDESTALS

2-1/4” TO 22” HIGH

TILE TECH PAVERS

CLAULKING

METAL COUNTERFLASHING

WATERPROOF MEMBRANE

STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH

ROOF DECK

ROOF DRAIN60psi MIN INSULATION

A1

ROOF WALL JUNCTURE

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 18

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 18: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

PERIMETER EDGE RESTRAINT OPTIONSMETAL FLASHING AND WOOD FASCIA CONTAINMENT DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LEDGER BOARD

FASCIA BOARD FLUSH WITHTOP OF PAVER

ROOF DECK

4“ø SDR35 P

VC

METAL FLASHING CONTAINMENT

WOOD FASCIA CONTAINMENT

ROOF DECK

4“ø SDR35 P

VC

TILE TECH PAVERS

DECK SCREWS

FASCIA BOARD MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF FASCIA BOARD CAN BE CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.

METAL FLASHING MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF METAL FLASHING CAN BE BENT OR CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.

LEDGER BOARD

TWO PIECE EDGE METAL

TILE TECH PAVERS

DECK SCREWS

PRE-FINISH METAL22GA. GALV.

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 19

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 19: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

PERIMETER EDGE RESTRAINT OPTIONSSTEP-DOWN AND GREEN ROOF CONTAINMENT DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.

ROOF DECK

4“ø SDR35 P

VC

STEP-DOWN CONTAINMENT

GREEN ROOF CONTAINMENT

FASCIA BOARD FLUSHWITH TOP OF PAVER

ROOF DECK

4“ø SDR35 P

VC

TILE TECH PAVERSVARIABLE RISER HEIGHT

(PER CODE)

LEDGER BOARD

UNI-JUST™ PEDESTALS2-1/4” TO 22” HIGH

ENGINEERED GREENROOF SOIL

FILTER FABRIC

L-CHANNEL WITHDRAIN HOLES

TILE TECH PAVERS

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 20

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 20: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

STEP-DOWN PEDESTAL APPLICATIONSTEP-DOWN PEDESTAL APPLICATION SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

2

TILE TECH PAVERS

ROOF DECK

UNI-JUST™ PEDESTALS2-1/4” TO 22” HIGH

LEDGER BOARD

FASCIA BOARD FLUSH WITHTOP OF PAVERS

VARIABLE RISER HEIGHT(PER CODE)

LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.

4“ø SDR35 P

VC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 21

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 21: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

WOOD TILE & PEDESTAL APPLICATIONTRANSITION, ALIGNMENT & LOCK DOWN DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

IPE WOOD & PAVER TRANSITION AND ALLIGNMENT

TILE TECH PAVERS™

UNI-SHIM™ USED FOR INDIVIDUAL

WOOD / PAVER ALIGNMENT

TILE TECH IPE™ WOOD

4“ø SDR35 P

VC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 22

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

DECK SCREW

LOCK WASHER

INSERT THE LOCK WASHER IN TO THE KURF CUT BETWEEN THE UPPER SLAT AND BOTTOM RAIL OF 3 WOOD PAVERS. INSERT THE 4th PAVER IN TO THE 4TH CORNER. ONCE ALL 4 PAVERS ARE TIGHTLY IN PLACE INSERT SCREW THROUGH LOCK WASHER AND HAND TIGHTEN IN TO PEDESTAL TOP UNTIL ALL 4 PAVERS ARE SECURELY FASTENED TO THE PEDESTAL. DO NOT OVER TIGHTEN.

Page 22: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

.

IPE WOOD TILES DETAILS20” x 20” x 1-1/2”

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 23

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

CROSS MEMBERTOP VIEW

Page 23: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

IPE WOOD TILES DETAILS24” x 24” x 1-5/8”

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 24

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

CROSS MEMBERTOP VIEW

Page 24: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

JOIST DECK & PEDESTAL APPLICATIONJOIST DECK INSTALLATION DETAILS & SPANNING CHART

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

NOTE:THIS DIAGRAM AND CHART ARE FOR CONVENIENCE ONLY. COMPATIBILITY OF DECKING MATERIAL AND JOIST SPANNING WILL VARY DEPENDING ON THE TYPE / SIZE OF CONCRETE PAVERS, WOOD OR COMPOSITE MATERIALS BEING USED. ADDITIONALLY CODE REQUIREMENTS VARY PER LOCATION AND IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE DECK MEETS CODE REQUIREMENTS.

2x8

2x10

12" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 10' - 0" 4x6 OR (2) 2x6 24" O.C.

13' - 2" 4x8 OR (2) 2x8 24" O.C.

16' - 10" 4X10 OR (2) 2x10 24" O.C.

16" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 9' - 1" 4x6 OR (2) 2x6 24" O.C.

2x8 12' - 0" 4x8 OR (2) 2x8 24" O.C.

2x10 15' - 2" 4X10 OR (2) 2x10 24" O.C.

20" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 7' - 11" 4x6 OR (2) 2x6 24" O.C.

2x8 10' - 2" 4x8 OR (2) 2x8 24" O.C.

2x10 12' - 5" 4X10 OR (2) 2x10 24" O.C.

JOIST SPAN

TILE TECH PAVERS

UNI-SHIM™

JOIST PLATE

PEDESTAL SPACING

UNI-JUST™ PEDESTALWITH JOIST CAP

JOIST HANGER

JOIST SPACING

BEAM SIZE1-4x OR 2-2x

DECK PLANKS

JOIST

JOIST HANGER

4“ø SDR35 PVC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 25

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Page 25: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

WIND-LOC™ PAVER & PEDESTAL APPLICATIONPAVER LOCK DOWN SYSTEM DETAILS. PLAN AND PROFILE VIEW

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

WIND-LOC™ - PROFILE VIEW

WIND-LOC™ PEDESTAL IS MADE OF HIGH IMPACT POLYPRO-PYLENE & ABS AND IS MADE TO LOCK THE PAVER SYSTEM TOGETHER AND PREVENT WIND UPLIFT. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON GRID LINES. SET THE WIND-LOC™ BASE ON TOP OF THE PEDESTAL SYSTEM AND SET WIND-LOC™ PAVERS ON TO WIND-LOC™ BASE. BE SURE TO ALIGN RECESS ON BACK SIDE OF PAVER WITH THE DOMES ON THE WIND-LOC™ BASE. POSITION & ALIGN WIND-LOC™ PLATE ON TO WIND-LOC™ PAVERS IN A DIAMOND CONFIGU-RATION. INSTALL WIND-LOC™ SCREW IN TO WIND-LOC™ BASE WITH A HEX BIT. TIGHTEN DOWN TO 80 PSI. DO NOT OVER TIGHTEN.

WIND-LOC™ PLATE

WIND-LOC™ SCREW

WIND-LOC™ BASE

WIND-LOC™ PAVERS

WIND-LOC™ PAVERSWIND-LOC™ SCREW

WIND-LOC™ PLATE

WIND-LOC™ BASE

UNI-JUST™ PEDESTAL

4“ø SDR35 PVC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 26

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Patent Pending

Pat. # 8,453,391 & Pat. Pen

Page 26: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

HEX-TRAY™ SNOW MELT SYSTEMPAVER SNOW MELT SYSTEM DETAILS. PLAN AND PROFILE VIEW

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH PAVERS PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

HEX-TRAY™ SNOW MELT - PROFILE VIEW

HEAT TRANSFER PLATE

TILE TECH PAVERS

FOAM INSULATION

Hex-Tray™ Snow Melt System

4“ø SDR35 PVC

COPYRIGHT 12/01/2010 TILE TECH PAVERS INC. , ALL RIGHTS RESERVED. Page 27

National Distribution

Paving America one step at a time!Tile Tech Pavers®

Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

HEX-TRAY™

PEX TUBING CHANNELS

4“ø SDR35 PVC

PEX TUBINGCHANNELS

TILE TECH PAVERS

FOAM INSULATION

HEX-TRAY™

HYBRID PEDESTAL SYSTEM

HEAT TRANSFER PLATE

Patent Pending

Pat. # 8,453,391 & Pat. Pen

PEX TUBING

HEX-TRAY™ SNOW MELT SYSTEM COMPONENTS INCLUDES A HONEYCOMB STRUCTURAL TRAY WITH PEX TUBING CHANNELS, A FOAM INSULATION PANEL, ALUMINUM HEAT TRANSFER PLATE AND USER SUPPLIED ½“ PEX TUBING. PRE ASSEMBLE THE FOAM INSULATION PANEL TO THE BACK OR BOTTOM SIDE OF THE HEX-TRAY AND SECURE WITH SUPPLIED CORK-SCREW. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON TO GRID LINES. PLACE SEMI ASSEMBLED HEX-TRAY™ ON TO PEDESTAL SYSTEM. LEVEL & SECURE FOUR ADJACENT CORNERS TO PEDESTAL SYSTEM USING PERFORATED LOCK DISK AND SECURE WITH SCREW. POSITION AND ALIGN HEAT TRANSFER PLATE TO TOP OF HEX-TRAY™. AT TERMINATION POINTS AND WALLS, CUT BACK HEAT TRANSFER PLATE TO EXPOSE THE “U” SHAPED CHANNELS IN ORDER TO LOOP BACK PEX TUBING. INSTALL PEX TUBING AND TEST FOR LEAKS. INSTALL PAVERS.

Page 27: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 1 of 7

PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

and Division 01 Specification Sections, apply to this Section. 1.2 Summary

A. Furnish and install a complete Architectural Pavers and Adjustable Pedestals deck support system with a maximum cavity height of up to 22 inches.

B. Related Sections include the following: 1. Division 02 - Section 02780 Unit Pavers

2. Division 03 - Section 03300 Cast-in-Place Concrete. 3. Division 06 - Section 06100 Rough Carpentry. 4. Division 07 - Section 07760 Roof Pavers. 5. Division 07 - Section 07620 Roof related Metal Work. 6. Division 07 - Section 07540 Fluid Applied Waterproofing. 7. Division 07 - Section 07540 Bituminous Sheet Waterproofing. 8. Division 07 - Section 07760 Roof Pavers.

1.3 REFERENCES A. American Society for Testing and Materials (ASTM) 1. ASTM D 638 - Tensile Properties of Plastics 2. ASTM D 790 - Flexural Properties of Unreinforced and Reinforced Plastics Insulating 3. ASTM D 1525 -Vicat Softening Temperature of Plastics 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Samples:

1. Architectural Pavers: Submit samples for type, color and texture required. 2. Pedestals: Submit sample of each pedestal component. 3. PVC Pipe: Submit 12-inch long sample of PVC pipe.

B. Shop Drawings: Submitted by contractor showing all components required for the paver & pedestal

requirements. Shop drawings shall include plan drawings showing layout of all paver areas and detail drawings showing how the various components of the system fit together. Include manufacturer’s literature completely describing all components of the paver pedestal systems and giving detailed installation recommendations and instructions. Also included detailed installation drawings for all precast pavers.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications: All products covered under this Section shall be produced by a single manufacturer unless otherwise specified with a minimum of fifteen (15) years proven production experience.

Page 28: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 2 of 7

B. Installer Qualifications: Installer shall have a minimum of three (3) years proven construction experience

and be capable of estimating & building from blueprint plans and details, determining elevations, in addition to proper material handling. All Work must comply with Tile Tech Pavers installation application procedures for pedestal mounted pavers as specified herein.

C. Special Consideration: The installer and or subcontractor must assume the responsibility for and take

into consideration (1) the structural capability and adequacy of the structure to carry the dead and live load weight(s) involved, and (2) that the density of any insulation is satisfactory to resist crushing and damaging the waterproofing membrane.

1.6 DELIVERY, STORAGE, AND HANDLING A. In accordance with provisions of Section 01300. B. Protect Concrete Pavers and Pedestal System during shipment, storage and construction against damage.

Store a minimum of 4 inches off the ground in a dry location and cover with polyethylene to protect from contact with materials which would cause staining or discoloration.

1.7 PROJECT CONDITIONS

A. Tile Tech Pedestal System specified are to be used with pedestrian traffic only & all four (4) sides of a deck system must restrain and contain the decking panels with perimeter blocking or walls. Decking panels must not be allowed to move laterally.

B. All membrane waterproofing and protection board surfaces to receive pedestals must be broom clean, frost

free, and free of dirt, oil or any rough foreign matter, which may impair the waterproofing / roofing manufacturers guarantee or protection requirements.

C. The substrate that is to receive pedestals must have slope and provide positive and adequate drainage in

accordance with good building practice and applicable building codes. D. Decks over Roofing and Waterproofing;

1. If high density closed cell extruded 60psi polystyrene insulation is installed on top of the membrane in a protected membrane system, Tile Tech Pedestals may be installed directly on top of this type of insulation.

2. Do not use Tile Tech Pedestals over any insulation less than 60psi or with low density polystyrene (bead board) insulation.

E. Decks on Grade:

1. Any substrate soil that is to receive pedestals shall be adequately compacted and have positive drainage slope. A “walkway gravel” base ie:¼” Minus should be installed and compacted at pedestal locations.

2. A wall or perimeter containment on all open sides is required. Install structural perimeter containment that restrains the entire decking system.

Page 29: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 3 of 7

F. Installation or anticipated installation of additional items on top of the deck such as planters, hot tubs,

sculptures, or industrial equipment must be supported directly by additional pedestals that are in addition to the main deck paver/tile pedestal system. Failure to adequately support the additional weight of any such features or items may cause significant damage to the deck, underlying structure, or waterproofing .

1.8 WARRANTIES / GUARANTEES

A. Tile Tech Pedestal System (pavers and pedestals) shall remain free from defects for a period of ten (10) years. The contractor shall warrant that his work will remain free from defects of labor and materials used in conjunction with his work in accordance with the general conditions for this project or a maximum of three (3) years.

PART 2 – PRODUCTS 2.1 MANUFACTURERS

A. The Paver Pedestal Systems specified herein are based upon products manufactured by: Tile Tech Pavers Inc, 888-380-5575 Phone: (213) 380-5560 Fax: (213) 380-5561 E-mail: [email protected] Website: www.tiletechpavers.com

B. Paver Pedestal Systems equal in appearance and function and meeting these specifications, will be

acceptable when the specified submittals are approved in writing by the Architect prior to bid. 2.2 MATERIALS A. PAVERS: 1. Type: Granite-Tech™, Stamp-Tech™, Cool-Roof™, Recycled Glass and Win-Lok™.

2. Color: Standard and custom range manufactured by Tile Tech Pavers Inc. 3. Size: 20”x20”x2”, 16”x16”x1-1/2” , 12”x12”x1” , 12”x24”x1-1/2” , 16”x24”x2” nominal 4. Finish: Shot-blasted with 3/16” bevel on all four (4) sides of finished surface. 5. Weight: 11 to 22 lbs per square foot depending on paver size & thickness.

B. PEDESTALS:

1. Stak-Cap™ Pedestals: PVC Pipe & Stack Adjustable a. Stack or use SDR35 PVC pipe to accommodate various HEIGHT adjustments of ½” to 8”. b. Each cap provides maximum of ½” of HEIGHT and 1% SLOPE. Rotate and stack one cap

relative to another to accommodate SLOPE adjustments from 0% to 5%. c. Base diameter of 6-inch and top diameter of 5-¼-inch and is ½-inch high.

d. Made of high impact and flame resistant ABS plastic. e. Use of Buffer Pads under Stak-Cap™ Pedestals is MANDATORY.

2. Uni-Just™ Pedestals: PVC Pipe & Screw Adjustable a. Assemply consist of 5 parts: Uni-Base™, Uni-Collar™, Uni-Insert™, Uni-Cap™ & Buffer

Pads. b. Use SDR35 PVC pipe to accommodate various HEIGHT adjustments from 2-½” to 22”. Additional precise height adjustment of up to 1-½” with the use of Uni-Insert™ which

can screw up or down while loaded. c. Self-leveling and can tilt in any direction to a level plane to accommodate SLOPE

adjustments from 0% to 6%.

Page 30: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 4 of 7

d. Base diameter of 7-inch with bearing surface area of thirty eight (38) square inches. e. Made of 100% recycled and flame resistant High Density Polypropylene. f. Use of Buffer Pads under Uni-Just™ Pedestals is MANDATORY.

3. Uni-Shims™: 1/8-inch & 1/16-inch Thick

a. Can be used whole or broken into halves or quarters and can be stacked up to 2 high. b. Used on top or under Stak-Cap™ or Uni-Just™ Pedestals for fine leveling of pedestals and

or individual pavers. c. Made of high impact and flame resistant ABS plastic.

C. OTHER COMPONENTS: INSTALLER OR USER SUPPLIED 1. Pedestal Pipe: 4-inch diameter SDR35 PVC Sewer Pipe

a. Used with either Stak-Cap™ or Uni-Just™ Pedestals and is cut to required height. b. Dimensions: 4.215-inch outside diameter & 3.890-inch inside diameter. c. Meet ASTM D-3034 and F-679.

b. NOT supplied with pedestal components by Tile Tech Pavers. 2. Protection Course:

a. Protection board (required over insulated BUR systems, and when specified for use over bituminous asphalt-based waterproofing): W.R. Meadows “Vibraflex” or equal, minimum 3/8- inch thick asphaltic composition protection board.

b. Insulation (when specified): Dow Styrofoam “Highload 100” or equal, minimum compressive strength of 100psi recommended for foam plastic insulation placed beneath Pedestal System to prevent damage to the waterproofing membrane.

c. NOT supplied with pedestal components by Tile Tech Pavers. 2.3 PERIMETER CONTAINMENT AND SUPPORT

A. The complete assembly of insulation (if used), protection board (if used), drainage mat (if used), pedestals and pavers must be restrained at the perimeter of the deck area.

B. Perimeter parapet walls, concrete dividers or other perimeter restraint must be capable of resisting lateral

forces (including seismic and wind). Cumulative movement in excess of 1/8 inch will void the Tile Tech Pavers Pedestal System warranty.

PART 3 – EXECUTION 3.1 EXAMINATION

A. Prior to starting work inspect the substrate to ensure that it has been properly prepared to accept the Tile Tech Pedestal System. The substrate and or surface shall be clean and free of any projections and debris which may impair the performance of the pedestal and or the deck system. Verify all elevations, required pedestal heights and deck dimensions. Commencement of work shall imply acceptance of surfaces & deck conditions.

B. If preparation is the responsibility of another installer, notify Architect in writing of deviations from

manufacturer's recommended installation tolerances and conditions.

Page 31: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 5 of 7

3.2 PREPARATION

A. The substrate surface that will receive the Pedestal System must be well compacted (on Grade) or structurally capable of carrying the dead and live loads anticipated. 1. Insulation OVER the membrane: (Option 1) Insulation and/or protection board (if specified) must

be applied over the waterproofing substrate and/or specified drainage mat. Install the system according to the membrane manufacturer’s recommendations and specifications.

2. Insulation UNDER membrane: (Option 2) Insulation required to be installed within a roofing system below deck supports must meet the roofing membrane manufacturers’ specifications and must have a minimum core density of 60psi.

3. Protection Board: (for asphalt type systems used over waterproofing) Full coverage 1/8-inch asphaltic composition protection board is recommended. When protection is specified only under the pedestal cut protection board pads to extend beyond the outside perimeter of the pedestal system base or buffer pad by a minimum of TWO (2) inch.

4. Drainage Mat: (when desired or specified) Install drainage mat according to the manufacturers recommendations to avoid crushing.

3.3 INSTALLATION

A. Install in accordance with Tile Tech Pavers and other contributing manufacturer's instructions. Installation requirements vary for each individual project site. Decking paver or tile used, pattern, grid layout, starting point, and finished elevation should be shown on plan view shop drawings, which have been prepared and approved by the designer, installing contractor and/or owner.

B. GRID LAYOUT AND ELEVATIONS: 1. Once the starting point and the finished elevation of the deck surface have been determined, the

“Top of Pedestal Elevation” (finished elevation less decking paver or tile thickness) is established and marked around the perimeter using a transit water level or laser leveling device.

2. Precise measurements should be taken and deck area should be accurately defined. Mark off and

‘square up’ all outside edges with control lines using "snapped" chalk lines. Mark two (2) lines that are perpendicular to each other across the deck area. Continue to mark a grid of lines in both directions marking the location of each pedestal. Use the control lines as references to periodically check and assure a square layout during installation.

3. Next, a pedestal must be placed where each measured grid line meets the perimeter. Remove two (2) spacer tabs in line with one another atop each pedestal system placed around the perimeter. Remove all four (4) spacer tabs at corners.

4. Adjust each pedestal height to the “Top of Pedestal Elevation” marked on the perimeter. Position

the pedestal as close to the edge of the perimeter as possible, with the two remaining spacer tabs aligned with the grid line. Using the elevation marked on the perimeter, stretch a mason’s line along and slightly ahead of the second row of pedestals. A laser leveling device may also be used for this purpose.

5. On larger decks, it is recommended that Tile Tech Pedestal System be pre-assembled and pre-set

to the proper elevation and placed in position prior to the installation of decking paver or tile.

Page 32: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 6 of 7

6. As the pedestals located along the grid lines are loaded with pavers or tiles, fine vertical height

adjustment can be made by inserting and rotating, from the top, a T-handle Hex Key in to the Uni-Insert™ of the Pedestal assembly. Clockwise rotation of the Uni-Insert™ will raise the bearing surface and the deck. Counter-clockwise rotation will lower the top bearing surface and deck.

7. Always maintain adequate thread engagement. Tile Tech Pedestal Uni-Insert™ contains a locking tab that will not allow the screw to extend past its maximum extension. Never use if the

locking tab is broken. If the height required goes beyond the Uni-Insert™ limit re-cut PVC pipe to the correct height and re-assemble the pedestal using the correct size pipe.

8. Slight irregularities in decking paver or tile thickness can be compensated for by using one (1) to

two (2) shim segments. Place on top of the pedestal, under the corner(s) of the decking paver or tile. Use no more than two (2) shims on top of the pedestal and always adhere quartered (1/4) wedges with construction adhesive.

9. Stak-Cap™ Pedestal can be used for limited and or fixed height requirements. Complete deck and

grid layout as instructed above. Stack no more than five (5) fixed height Stak-Cap™ Pedestals together and place in lieu of Uni-Just™ Pedestals where needed. Stak-Cap™ Pedestal can also be used with PVC pipe to reduce cost. Spacer tabs can be removed to accommodate perimeter and corner support locations.

C. SLOPE AND HEIGHT COMPENSATION:

1. Stak-Cap™ Pedestals can provide limited slope and height compensation to maintain a level decking surface over sloping substrates and is accomplished using a combination of the following: a. Rotate and stack one cap in relation to another to change slope and add height. Each cap

will add ½-inch of height and provide 1% slope. Stack no more than 5 caps. b. Can also be used with PVC Pipe cut to required height of maximum of 6-inches.

2. Uni-Just™ Pedestals can provide both slope and height compensation to maintain a level decking surface over sloping substrates and is accomplished using a combination of the following:

a. PVC Pipe cut to varying lengths to compensate for GENERAL height requirements. b. SCREW extension for PRECISE height adjustment.

c. Self-Leveling cap that pivots and tilts in any direction for slope compensation from 0% to 6%.

3. Tile Tech Pedestals are designed to be rotated for final precise adjustment when they are fully

loaded. Pedestals should be leveled in each succeeding row as the installation proceeds. Final height adjustment or maintenance is easily made by simply using a T-handle Hex Key that allows you to adjust the pedestals without removing the pavers. T-handle Hex Key is inserted between the four paver corners to engage Uni-Insert™ portion and is adjusted clockwise or counter clockwise to level as needed.

4. Uni-Shims™ may be used in multiples, whole or quarters, and placed under the pedestal base or

on top the pedestal cap to level pedestals. Use a small amount of construction adhesive to adhere sections of shims and/or whole shims to each other or to the pedestal. DO NOT use construction adhesive to adhere pedestal or shims to insulation, roofing or waterproofing membrane. Additional sections of shims may be used and should be available for regular maintenance.

Page 33: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

SECTION 07760 National Distribution 888-380-5575 ROOF PAVER SYSTEM

© 2012 Tile Tech Pavers Inc, All Rights Reserved. Page 7 of 7

3.4 PERIMETER CONTAINMENT

A. Any area of the pedestal deck that is not restrained by a parapet or foundation wall must be ‘boxed-in’ and contained. The deck panels will move if all sides are not adequately restrained. Perimeter framing and

edging boards located at the outside of the deck perimeter must be installed to provide restraint. No movement should be allowed at the perimeter of the deck system greater than one tab width.

3.5 FIELD QUALITY CONTROL

A. Inspect often during installation to assure that grid spacer lines are being maintained in a straight and consistent pattern and that deck pavers or tiles are level and not rocking. Unless otherwise specified in writing to allow for expansion, inspect to assure that all paver spacing between tiles and at perimeter walls does not exceed a tab width. Particular attention should be made to assure that all pedestrian entry or access points to the deck are level and that the deck surface tiles are not randomly raised or uneven creating a tripping or safety hazard. Confirm that deck pedestal height excess of sixteen (16) inches have been braced in accordance with Tile Tech Pavers written instructions.

3.6 ROUTINE MAINTENANCE AND CARE

A. The deck owner must perform routine maintenance of the deck. Check for rocking pavers and adjust using T-Handle Hex Key or shim immediately. Pedestals can settle and may have to be realigned. Failure to do so can cause a tripping hazard. Periodically check spacer tabs and immediately replace broken tabs to limit deck movement. Make sure the edge restraint stays intact and structurally sound.

B. Extra Materials: Deliver supply of maintenance materials to the owner. Furnish not less than 1 percent

maintenance materials from same lot as materials installed, and enclosed in protective packaging with appropriate identifying labels.

END OF SECTION 07760 ROOF PAVERS AND PEDESTALS

Page 34: Tile Tech Pavers€¦ · 23. wood tiles 20x20 details 24. wood tiles 24x24 details 25. joist deck pedestal application 26. win-loc™ paver paver lock down system for wind uplift

Visit our website at www.tiletechpavers.com

for complete design details and photo gallery

Paving America one step at a time!Tile Tech Pavers®

©1996-2013 Tile Tech Pavers

HP-D 01/14

MADE IN AMERICA

888-380-5575 213-380-5561 [email protected] www.TileTechPavers.com