smart climate 22...115vac 1/4hp (187w), 230vac 1/2hp (373w), 7.5 amp res. max. we recommend...
Post on 15-Aug-2021
1 Views
Preview:
TRANSCRIPT
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
ENW
IRIN
G D
IAG
RAM
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
*[P
C li
ne]
Red
Black
Shield
Con
nect
or A
SUR
ELIN
K-2
MO
DU
LE
A-B
OX
Com
mun
icat
ion
Syst
em H
ook-
up (O
ptio
nal)
AgN
et C
omm
unic
atio
n Sy
stem
Hoo
k-up
(Opt
iona
l)
* R
efer
to th
e S
ureL
ink-
2 m
anua
l to
set
the
end
of li
ne
jum
pers
(EO
L)
prop
erly
on
the
PC
co
mm
unic
atio
n lin
e.
EOL
= Ye
s[P
C li
ne]
NO
YES
END
OF
LIN
E
12
34
TxR
xG
LN
G
76
54
32
1M
odem
or
com
pute
r
RedGreen
White
Com
pute
r or
mod
em
BR
IDG
E-A
1
END
OF
LIN
E
23
EOL
= Ye
s[P
C li
ne]
EOL
= ye
s*[P
C li
ne]
PCG
H
PC1
PC2
FE OUT-
MA
IN C
ON
TRO
LLER
A-C
om c
ard
PCG
H
PC1
PC2
FE
MA
IN C
ON
TRO
LLER
CO
MLI
NK
-1 C
AR
D
N-
+G
LFI
LTER
CLO
OPN
INW
INC
HR
ETU
RN {
L1
GN
D N
+18VAC
-18VAC
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
ACTU
ATO
R
AC
TUAT
OR
POW
ER S
UPP
LY23
0 VA
C (1
15 V
AC)
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D
L2
( N
)
T
T
T
T
CLOSE
OPEN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
MOVING GND (WIPER)
OUTSIDE
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
CLOSE
OPEN
AC
TU
AT
OR
PO
WE
R
SU
PP
LY11
5 V
AC
18 T
O 3
6 V
DC
TR
AN
SFO
RM
ER
ACTU
ATO
R
{CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTENTIOMETER
BLAC
K
RED
YELL
OW
18AW
GSH
IELD
EDC
AB
LES
ACTU
ATO
RPO
WER
SUP
PLY
115
VAC
CLOSE
OPEN
Von
Wei
se A
ctua
tor V
-76-
115
115
VAC
Mot
or w
ith p
oten
tiom
eter
(1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
WHITE *
BLUE (MOVING GND WIPER) *
ORANGE
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
CLO
OPN
INW
INC
HR
ETU
RN
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
RED
BLACK
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
L1
{
GN
D(
N )
AC
TUAT
OR
POW
ER S
UPP
LY11
5 VA
CW
HIT
EG
REE
N
with
pot
entio
met
er (1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
YELLOW (POT. WIPER)
18AW
GSH
IELD
EDC
AB
LES
MOVING GND (WIPER)
18AW
GSH
IELD
EDC
AB
LES
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
*IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
BLACK
RED
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
VIC
JA
CK
AC
TU
AT
OR
- AC
MO
TO
R
VIC
JACK
ACT
UATO
R
18AW
GSH
IELD
EDC
AB
LES
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
To B
ridge
-A
OU
T +
OU
T -
G 1
{ AlarmNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
TO T
ERM
INA
L #
8TO
TER
MIN
AL
# 9
TO T
ERM
INA
L #1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
Controller Power Supply230 Vac (115 Vac)
Stage 3 On/Off OutputPower Supply230 Vac (115 Vac)
Variable-speed Fan
Fan, Heater or Mister
Stage 4 On/Off OutputPower Supply230 Vac (115 Vac)
Stage 1 Variable OutputPower Supply230 Vac (115 Vac)
Stage 2Variable OutputPower Supply230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
0-10VLoad 2
0-10VLoad 1
Dwyer GaugeStatic PressureSensor (Opt.)
GND
L1
L2 (N)
On-Off
GND
L1
L2 (N)
Fan, Heater or Mister
On-Off
GND
L1
L2 (N)
GND
L1
L2 (N)
Variable-speed Fan
GND
L1
L2 (N)
Cable Entry:Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure.
Mounting the Enclosure on the Wall:Leave a clearance of at least 12” above controller to allow the cover to be removed for maintenance.
*Backup Thermostats:The backup thermostats are shown for illustration purposes only. Sufficient backup thermostats must be used to ensure ventilation if the controller loses power.
Fuse Box:We recommend installing a fuse box on each stage.
Notes:1. Installation of a good quality alarm system is strongly suggested to warn of power failures and high/low temperatures.
2. Provide a surge protection (including lightning protection) from the power supply to the controller and from the control to the sensors. Consult a certified electrician if required.
3. Same phases must be used to power the variable fans and the controls on 3 phases power.
Variable Output Capacity:115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Actuator (winch): Open/Close output, 120VAC (0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
The water meter output should be a dry contact and should not pulse faster than 60 times a second (60 Hz).
A 22/12 AWG gauge cable no longer than 2000 feet (0.6 km) can be used to connect the water meter. Do not use a cable longer than 2000 feet even if a larger cable is used. Do not run the meter cable outside the building !
Water Meter:
Coil
N.O.
N.O.COM
COM{
{
Coil power source
Stage output
from control
to distribution panelstage input
ON/OFF Ouput Capacity:115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max. We recommend installing external relays on "on/off" stages hooked to motors.
Voltage Selector115/230 Vac
J2 Connector
Connectionfor top board
Com
mun
icat
ion
Con
nect
ion
(Com
link-
1 C
ard) Smart Climate 22
See overleafto connect the actuators
See overleaf to connectthe potentiometer
See overleafto connect the sensors
Backup Thermostat*(Not included)
Backup Thermostat*(Not included)
Relative humiditysensor HS-1
(Optional)
1 2 3 4
HP1, HS-100Humidity sensor
(Old model)
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
ENW
IRIN
G D
IAG
RAM
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
*[P
C li
ne]
Red
Black
Shield
Con
nect
or A
SUR
ELIN
K-2
MO
DU
LE
A-B
OX
Com
mun
icat
ion
Syst
em H
ook-
up (O
ptio
nal)
AgN
et C
omm
unic
atio
n Sy
stem
Hoo
k-up
(Opt
iona
l)
* R
efer
to th
e S
ureL
ink-
2 m
anua
l to
set
the
end
of li
ne
jum
pers
(EO
L)
prop
erly
on
the
PC
co
mm
unic
atio
n lin
e.
EOL
= Ye
s[P
C li
ne]
NO
YES
END
OF
LIN
E
12
34
TxR
xG
LN
G
76
54
32
1M
odem
or
com
pute
r
RedGreen
White
Com
pute
r or
mod
em
BR
IDG
E-A
1
END
OF
LIN
E
23
EOL
= Ye
s[P
C li
ne]
EOL
= ye
s*[P
C li
ne]
PCG
H
PC1
PC2
FE OUT-
MA
IN C
ON
TRO
LLER
A-C
om c
ard
PCG
H
PC1
PC2
FE
MA
IN C
ON
TRO
LLER
CO
MLI
NK
-1 C
AR
D
N-
+G
LFI
LTER
CLO
OPN
INW
INC
HR
ETU
RN {
L1
GN
D N
+18VAC
-18VAC
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
ACTU
ATO
R
AC
TUAT
OR
POW
ER S
UPP
LY23
0 VA
C (1
15 V
AC)
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D
L2
( N
)
T
T
T
T
CLOSE
OPEN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
MOVING GND (WIPER)
OUTSIDE
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
CLOSE
OPEN
AC
TU
AT
OR
PO
WE
R
SU
PP
LY11
5 V
AC
18 T
O 3
6 V
DC
TR
AN
SFO
RM
ER
ACTU
ATO
R
{CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTENTIOMETER
BLAC
K
RED
YELL
OW
18AW
GSH
IELD
EDC
AB
LES
ACTU
ATO
RPO
WER
SUP
PLY
115
VAC
CLOSE
OPEN
Von
Wei
se A
ctua
tor V
-76-
115
115
VAC
Mot
or w
ith p
oten
tiom
eter
(1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
WHITE *
BLUE (MOVING GND WIPER) *
ORANGE
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
CLO
OPN
INW
INC
HR
ETU
RN
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
RED
BLACK
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
L1
{
GN
D(
N )
AC
TUAT
OR
POW
ER S
UPP
LY11
5 VA
CW
HIT
EG
REE
N
with
pot
entio
met
er (1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
YELLOW (POT. WIPER)
18AW
GSH
IELD
EDC
AB
LES
MOVING GND (WIPER)
18AW
GSH
IELD
EDC
AB
LES
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
*IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
BLACK
RED
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
VIC
JA
CK
AC
TU
AT
OR
- AC
MO
TO
R
VIC
JACK
ACT
UATO
R
18AW
GSH
IELD
EDC
AB
LES
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
To B
ridge
-A
OU
T +
OU
T -
G 1
{ AlarmNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
TO T
ERM
INA
L #
8TO
TER
MIN
AL
# 9
TO T
ERM
INA
L #1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
Controller Power Supply230 Vac (115 Vac)
Stage 3 On/Off OutputPower Supply230 Vac (115 Vac)
Variable-speed Fan
Fan, Heater or Mister
Stage 4 On/Off OutputPower Supply230 Vac (115 Vac)
Stage 1 Variable OutputPower Supply230 Vac (115 Vac)
Stage 2Variable OutputPower Supply230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
0-10VLoad 2
0-10VLoad 1
Dwyer GaugeStatic PressureSensor (Opt.)
GND
L1
L2 (N)
On-Off
GND
L1
L2 (N)
Fan, Heater or Mister
On-Off
GND
L1
L2 (N)
GND
L1
L2 (N)
Variable-speed Fan
GND
L1
L2 (N)
Cable Entry:Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure.
Mounting the Enclosure on the Wall:Leave a clearance of at least 12” above controller to allow the cover to be removed for maintenance.
*Backup Thermostats:The backup thermostats are shown for illustration purposes only. Sufficient backup thermostats must be used to ensure ventilation if the controller loses power.
Fuse Box:We recommend installing a fuse box on each stage.
Notes:1. Installation of a good quality alarm system is strongly suggested to warn of power failures and high/low temperatures.
2. Provide a surge protection (including lightning protection) from the power supply to the controller and from the control to the sensors. Consult a certified electrician if required.
3. Same phases must be used to power the variable fans and the controls on 3 phases power.
Variable Output Capacity:115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Actuator (winch): Open/Close output, 120VAC (0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
The water meter output should be a dry contact and should not pulse faster than 60 times a second (60 Hz).
A 22/12 AWG gauge cable no longer than 2000 feet (0.6 km) can be used to connect the water meter. Do not use a cable longer than 2000 feet even if a larger cable is used. Do not run the meter cable outside the building !
Water Meter:
Coil
N.O.
N.O.COM
COM{
{
Coil power source
Stage output
from control
to distribution panelstage input
ON/OFF Ouput Capacity:115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max. We recommend installing external relays on "on/off" stages hooked to motors.
Voltage Selector115/230 Vac
J2 Connector
Connectionfor top board
Com
mun
icat
ion
Con
nect
ion
(Com
link-
1 C
ard) Smart Climate 22
See overleafto connect the actuators
See overleaf to connectthe potentiometer
See overleafto connect the sensors
Backup Thermostat*(Not included)
Backup Thermostat*(Not included)
Relative humiditysensor HS-1
(Optional)
1 2 3 4
HP1, HS-100Humidity sensor
(Old model)
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
ENW
IRIN
G D
IAG
RAM
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
ENWIRING DIAGRAM
SMART CLIMATE 22
#891-00498 REV 03
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
*[P
C li
ne]
Red
Black
Shield
Con
nect
or A
SUR
ELIN
K-2
MO
DU
LE
A-B
OX
Com
mun
icat
ion
Syst
em H
ook-
up (O
ptio
nal)
AgN
et C
omm
unic
atio
n Sy
stem
Hoo
k-up
(Opt
iona
l)
* R
efer
to th
e S
ureL
ink-
2 m
anua
l to
set
the
end
of li
ne
jum
pers
(EO
L)
prop
erly
on
the
PC
co
mm
unic
atio
n lin
e.
EOL
= Ye
s[P
C li
ne]
NO
YES
END
OF
LIN
E
12
34
TxR
xG
LN
G
76
54
32
1M
odem
or
com
pute
r
RedGreen
White
Com
pute
r or
mod
em
BR
IDG
E-A
1
END
OF
LIN
E
23
EOL
= Ye
s[P
C li
ne]
EOL
= ye
s*[P
C li
ne]
PCG
H
PC1
PC2
FE OUT-
MA
IN C
ON
TRO
LLER
A-C
om c
ard
PCG
H
PC1
PC2
FE
MA
IN C
ON
TRO
LLER
CO
MLI
NK
-1 C
AR
D
N-
+G
LFI
LTER
CLO
OPN
INW
INC
HR
ETU
RN {
L1
GN
D N
+18VAC
-18VAC
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
ACTU
ATO
R
AC
TUAT
OR
POW
ER S
UPP
LY23
0 VA
C (1
15 V
AC)
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D
L2
( N
)
T
T
T
T
CLOSE
OPEN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
MOVING GND (WIPER)
OUTSIDE
POTE
NTI
OM
ETER
(1, 5
or 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
CLOSE
OPEN
AC
TU
AT
OR
PO
WE
R
SU
PP
LY11
5 V
AC
18 T
O 3
6 V
DC
TR
AN
SFO
RM
ER
ACTU
ATO
R
{CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
POTENTIOMETER
BLAC
K
RED
YELL
OW
18AW
GSH
IELD
EDC
AB
LES
ACTU
ATO
RPO
WER
SUP
PLY
115
VAC
CLOSE
OPEN
Von
Wei
se A
ctua
tor V
-76-
115
115
VAC
Mot
or w
ith p
oten
tiom
eter
(1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
WHITE *
BLUE (MOVING GND WIPER) *
ORANGE
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
CLO
OPN
INW
INC
HR
ETU
RN
T
T
T
T
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
WA
TE
RM
ET
ER
(OPT
ION
AL)
OUTSIDE
RED
BLACK
INSIDE T° SENSOR #1
INSIDE T° SENSOR #2 (OPT.)
INSIDE T° SENSOR #3 (OPT.)
INSIDE T° SENSOR #4 (OPT.)
OUTSIDE T° SENSOR (OPT.)
L1
{
GN
D(
N )
AC
TUAT
OR
POW
ER S
UPP
LY11
5 VA
CW
HIT
EG
REE
N
with
pot
entio
met
er (1
, 5 O
R 1
0 K
ohm
s, 1
0 Tu
rns)
YELLOW (POT. WIPER)
18AW
GSH
IELD
EDC
AB
LES
MOVING GND (WIPER)
18AW
GSH
IELD
EDC
AB
LES
THE
RES
ISTA
NC
EIN
CR
EASE
S O
N 1
3 &
14
WH
EN O
PEN
ING
*IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
BLACK
RED
IT IS
IMPO
RTA
NT
TOC
ON
NEC
T TH
E TE
RM
INA
LW
ITH
TH
E A
CTU
ATO
R
WIN
CH
R
ETU
RN
VIC
JA
CK
AC
TU
AT
OR
- AC
MO
TO
R
VIC
JACK
ACT
UATO
R
18AW
GSH
IELD
EDC
AB
LES
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
To B
ridge
-A
OU
T +
OU
T -
G 1
{ AlarmNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
TO T
ERM
INA
L #
8TO
TER
MIN
AL
# 9
TO T
ERM
INA
L #1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
Controller Power Supply230 Vac (115 Vac)
Stage 3 On/Off OutputPower Supply230 Vac (115 Vac)
Variable-speed Fan
Fan, Heater or Mister
Stage 4 On/Off OutputPower Supply230 Vac (115 Vac)
Stage 1 Variable OutputPower Supply230 Vac (115 Vac)
Stage 2Variable OutputPower Supply230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
0-10VLoad 2
0-10VLoad 1
Dwyer GaugeStatic PressureSensor (Opt.)
GND
L1
L2 (N)
On-Off
GND
L1
L2 (N)
Fan, Heater or Mister
On-Off
GND
L1
L2 (N)
GND
L1
L2 (N)
Variable-speed Fan
GND
L1
L2 (N)
Cable Entry:Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure.
Mounting the Enclosure on the Wall:Leave a clearance of at least 12” above controller to allow the cover to be removed for maintenance.
*Backup Thermostats:The backup thermostats are shown for illustration purposes only. Sufficient backup thermostats must be used to ensure ventilation if the controller loses power.
Fuse Box:We recommend installing a fuse box on each stage.
Notes:1. Installation of a good quality alarm system is strongly suggested to warn of power failures and high/low temperatures.
2. Provide a surge protection (including lightning protection) from the power supply to the controller and from the control to the sensors. Consult a certified electrician if required.
3. Same phases must be used to power the variable fans and the controls on 3 phases power.
Variable Output Capacity:115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Actuator (winch): Open/Close output, 120VAC (0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
The water meter output should be a dry contact and should not pulse faster than 60 times a second (60 Hz).
A 22/12 AWG gauge cable no longer than 2000 feet (0.6 km) can be used to connect the water meter. Do not use a cable longer than 2000 feet even if a larger cable is used. Do not run the meter cable outside the building !
Water Meter:
Coil
N.O.
N.O.COM
COM{
{
Coil power source
Stage output
from control
to distribution panelstage input
ON/OFF Ouput Capacity:115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max. We recommend installing external relays on "on/off" stages hooked to motors.
Voltage Selector115/230 Vac
J2 Connector
Connectionfor top board
Com
mun
icat
ion
Con
nect
ion
(Com
link-
1 C
ard) Smart Climate 22
See overleafto connect the actuators
See overleaf to connectthe potentiometer
See overleafto connect the sensors
Backup Thermostat*(Not included)
Backup Thermostat*(Not included)
Relative humiditysensor HS-1
(Optional)
1 2 3 4
HP1, HS-100Humidity sensor
(Old model)
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
FRSC
HÉM
A D
E BR
AN
CHEM
ENT
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
Veuillez scanner le code QR pour accéder aux manuels complets ou visiter le site Web.
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
n*[L
igne
PC
]
Rouge
Noir
Blindage
Con
nect
eur A
MO
DU
LE S
UR
ELIN
K*
Se
réfé
rer a
u m
anue
l dí
utili
satio
n du
m
odul
e S
urel
ink
pour
régl
er le
s ca
valie
rs d
e fin
de
ligne
(EO
L)
NO
NO
UI
FIN
DE
LIG
NE
(EO
L)
12
34
TxR
xG
LN
G
76
54
32
1O
rdin
ateu
rou
mod
em
RougeVert
Blanc
Ord
inat
eur o
u m
odem
BR
IDG
E-A
12
3
EOL
= ou
i*[L
igne
PC
]
PCG
H
PC1
PC2
FE OUT-
CO
NTR
ÔLE
UR
PR
INC
IPA
L
CA
RTE
“EN
AB
LER
”
PCG
H
PC1
PC2
FE
CA
RTE
“C
OM
LIN
K-1
”
Bra
nche
men
t de
la c
omm
unic
atio
n po
ur
A
-BO
X(o
ptio
nnel
)
Bra
nche
men
t de
la c
omm
unic
atio
npo
ur
A
gNet
(opt
ionn
el)
EOL
= ou
i[L
igne
PC
]
CO
NTR
ÔLE
UR
PR
INC
IPA
L
EOL
= ou
i[L
igne
PC
]FI
N D
E LI
GN
E (E
OL)
JAU
NE
NO
IR
RO
UG
E
POTENTIOMÉTRE {A
ctua
teur
Von
Wei
se V
-76-
115
Mot
eur 1
15 V
AC
ave
c po
tent
iom
ètre
(1, 5
ou
10 K
ohm
s, 1
0 to
urs)
BLANC
BLEU (CONTACT MOBILE)
ORANGE
N-
+G
LFI
LTR
E
TR
AN
SFO
RM
AT
EU
R18
À 3
6 V
DC
ACTU
ATEU
R
CLO
OPN
INW
INC
HR
ETU
RN
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
ACTU
ATEU
R
L1
{
GN
D
L2
( N
)AL
IMEN
ATIO
N DE
L'
ACTU
ATEU
R23
0 VA
C (1
15VA
C)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
CLO
OPN
INW
INC
HR
ETU
RN
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
FERMER
OUVRIR
AL
IME
NTA
TIO
NA
CT
UA
TE
UR
115
VA
C{
L1
GN
D N
T
T
T
T
T° EXT
T
T
T
T
T° EXT
+18VAC
-18VAC
FERMER
OUVRIR
FERMER
OUVRIR
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
T
T
T
T
T° EXT
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
CÂ
BLE
S B
LIN
DÉS
18AW
G
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.) AC
TU
AT
EU
R V
IC J
AC
K :
MO
TE
UR
AC
LA R
ÉSIS
TAN
CE
AU
GEM
ENTE
SU
R 1
3 ET
14
EN O
UVE
RTU
RE
CLO
OPN
INW
INC
HR
ETU
RN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
ROUGE
NOIR
L1
{
GN
D(
N )
BLA
NC
VER
T
T
T
T
T
T° EXT
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
JAUNE (CONTACT MOBILE)
NOIR
ROUGE
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
ACTU
ATEU
R VI
C JA
CKav
ec p
oten
tiom
ètre
(1, 5
OU
10 K
ohm
s, 1
0 To
urs)
IMPO
RTA
NT
:B
RA
NC
HER
CO
RR
ECTE
MEN
TLE
BO
RN
IER
Â
L’A
CTU
ATEU
RW
INC
H
RET
UR
N
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
 L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
À L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
CÂ
BLE
S B
LIN
DÉS
18AW
G
Actuateur (treuil) : sortie d’ouverture et de fermeture, 120VAC(0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
Compteur d’eau :La sortie du compteur d’eau doit être un contact sec et ne doit pas pulser plus rapidement que 60 fois la seconde (60 Hz).Un câble de calibre 22/12 AWG ne dépassant pas 2000 pieds (0,6 km) peut être utilisé pour raccorder le compteur d’eau. Ne pas utiliser un câble plus long que 2000 pieds même si le câble utilisé est plus gros.Ne pas faire courir le câble du compteur d’eau à l’extérieur du bâtiment !
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
Vers
r Brid
ge-A
OU
T +
OU
T -
G 1
{ AlarmeNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
Vers
bor
nier
n°8
Vers
bor
nier
n°9
Vers
bor
nier
n°1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
ContrôleurAlimentation230 Vac (115 Vac)
Stage 3 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 4 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 1 Sortie variableAlimentation230 Vac (115 Vac)
Stage 2Sortie variableAlimentation230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
Charge0-10V n°2
Sonde depression statique
Dwyer Gauge(Opt.)
GND
L1
L2 (N)
Marche-arrêt
GND
L1
L2 (N)
Ventilateur, chauffage ou brumisateur
Marche-arrêt
GND
L1
L2 (N)
GND
L1
L2 (N)
GND
L1
L2 (N)
Entrée des câbles: Passer tous les câbles sous le boîtier. Ne pas percer de trous sur les côtés ou sur le dessus du boîtier pour éviter les infiltrations d'eau.
Fixation du contrôleur au mur : Laisser un espace libre d’au moins 12 pouces au-dessus du contrôleur pour permettre de souleverle couvercle et d’effectuer un entretien.
*Thermostats de secours :Les thermostats de secours sont montrés à titre d’exemple. Utilisez suffisamment de thermostats de secours pour assurer la ventilation en cas de défaillance du contrôleur.
Coil
N.O.
N.O.COM
COM{
{
Alimentation bobine
Stage sortie
du contrôle
au panneau de distibution électriquestage entrée
Capacité des sorties variables :115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Capacité des sorties marche-arrêt :115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max.
Il est recommandé d’installer des relais externes sur les stages marche-arrêt reliés aux moteurs
Sélecteur de tension115/230 Vac
Connecteur J2
Connecteur pour le couvercle
Con
nect
eur p
our
carte
de
com
mun
icat
ion
(Com
link-
1) Smart Climate 22
Voir au verso pour lebranchement du
potentiomètreVoir au verso pour le
branchement des sondes
Thermostat de secours *(non-inclus)
Thermostat de secours* (non-inclus)
Ventilateur à vitesse variable
Ventilateur, chauffage ou brumisateur
Ventilateur à vitesse variableCharge0-10V n°1
Boîtes à fusibles : Nous recommandons d’installer une boîte à fusible sur chaque stage.
Notes :1. L’installation d’un système d’alarme est fortement recommandée afin de détecter les pertes de courant et les hautes/ basses températures.
2. Des protecteurs de surtension sont recommandés entre l’alimentation, le contrôleur et les sondes. Consulter un électricien au besoin.
3. Lors d’une alimentation 3 phases, les mêmes phases doivent être utilisées pour alimenter les ventilateurs variables et le
Voir au verso pour le branchement des
actuateurs
1 2 3 4
Sonde d’humiditérelative HS-1(Optionnel)
Sonde d’humiditéHP1, HS-100
(Ancien modèle)
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
FRSC
HÉM
A D
E BR
AN
CHEM
ENT
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
n*[L
igne
PC
]
Rouge
Noir
Blindage
Con
nect
eur A
MO
DU
LE S
UR
ELIN
K*
Se
réfé
rer a
u m
anue
l dí
utili
satio
n du
m
odul
e S
urel
ink
pour
régl
er le
s ca
valie
rs d
e fin
de
ligne
(EO
L)
NO
NO
UI
FIN
DE
LIG
NE
(EO
L)
12
34
TxR
xG
LN
G
76
54
32
1O
rdin
ateu
rou
mod
em
RougeVert
Blanc
Ord
inat
eur o
u m
odem
BR
IDG
E-A
12
3
EOL
= ou
i*[L
igne
PC
]
PCG
H
PC1
PC2
FE OUT-
CO
NTR
ÔLE
UR
PR
INC
IPA
L
CA
RTE
“EN
AB
LER
”
PCG
H
PC1
PC2
FE
CA
RTE
“C
OM
LIN
K-1
”
Bra
nche
men
t de
la c
omm
unic
atio
n po
ur
A
-BO
X(o
ptio
nnel
)
Bra
nche
men
t de
la c
omm
unic
atio
npo
ur
A
gNet
(opt
ionn
el)
EOL
= ou
i[L
igne
PC
]
CO
NTR
ÔLE
UR
PR
INC
IPA
L
EOL
= ou
i[L
igne
PC
]FI
N D
E LI
GN
E (E
OL)
JAU
NE
NO
IR
RO
UG
E
POTENTIOMÉTRE {A
ctua
teur
Von
Wei
se V
-76-
115
Mot
eur 1
15 V
AC
ave
c po
tent
iom
ètre
(1, 5
ou
10 K
ohm
s, 1
0 to
urs)
BLANC
BLEU (CONTACT MOBILE)
ORANGE
N-
+G
LFI
LTR
E
TR
AN
SFO
RM
AT
EU
R18
À 3
6 V
DC
ACTU
ATEU
R
CLO
OPN
INW
INC
HR
ETU
RN
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
ACTU
ATEU
R
L1
{
GN
D
L2
( N
)AL
IMEN
ATIO
N DE
L'
ACTU
ATEU
R23
0 VA
C (1
15VA
C)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
CLO
OPN
INW
INC
HR
ETU
RN
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
FERMER
OUVRIR
AL
IME
NTA
TIO
NA
CT
UA
TE
UR
115
VA
C{
L1
GN
D N
T
T
T
T
T° EXT
T
T
T
T
T° EXT
+18VAC
-18VAC
FERMER
OUVRIR
FERMER
OUVRIR
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
T
T
T
T
T° EXT
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
CÂ
BLE
S B
LIN
DÉS
18AW
G
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.) AC
TU
AT
EU
R V
IC J
AC
K :
MO
TE
UR
AC
LA R
ÉSIS
TAN
CE
AU
GEM
ENTE
SU
R 1
3 ET
14
EN O
UVE
RTU
RE
CLO
OPN
INW
INC
HR
ETU
RN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
ROUGE
NOIR
L1
{
GN
D(
N )
BLA
NC
VER
T
T
T
T
T
T° EXT
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
JAUNE (CONTACT MOBILE)
NOIR
ROUGE
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
ACTU
ATEU
R VI
C JA
CKav
ec p
oten
tiom
ètre
(1, 5
OU
10 K
ohm
s, 1
0 To
urs)
IMPO
RTA
NT
:B
RA
NC
HER
CO
RR
ECTE
MEN
TLE
BO
RN
IER
Â
L’A
CTU
ATEU
RW
INC
H
RET
UR
N
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
 L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
À L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
CÂ
BLE
S B
LIN
DÉS
18AW
G
Actuateur (treuil) : sortie d’ouverture et de fermeture, 120VAC(0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
Compteur d’eau :La sortie du compteur d’eau doit être un contact sec et ne doit pas pulser plus rapidement que 60 fois la seconde (60 Hz).Un câble de calibre 22/12 AWG ne dépassant pas 2000 pieds (0,6 km) peut être utilisé pour raccorder le compteur d’eau. Ne pas utiliser un câble plus long que 2000 pieds même si le câble utilisé est plus gros.Ne pas faire courir le câble du compteur d’eau à l’extérieur du bâtiment !
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
Vers
r Brid
ge-A
OU
T +
OU
T -
G 1
{ AlarmeNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
Vers
bor
nier
n°8
Vers
bor
nier
n°9
Vers
bor
nier
n°1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
ContrôleurAlimentation230 Vac (115 Vac)
Stage 3 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 4 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 1 Sortie variableAlimentation230 Vac (115 Vac)
Stage 2Sortie variableAlimentation230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
Charge0-10V n°2
Sonde depression statique
Dwyer Gauge(Opt.)
GND
L1
L2 (N)
Marche-arrêt
GND
L1
L2 (N)
Ventilateur, chauffage ou brumisateur
Marche-arrêt
GND
L1
L2 (N)
GND
L1
L2 (N)
GND
L1
L2 (N)
Entrée des câbles: Passer tous les câbles sous le boîtier. Ne pas percer de trous sur les côtés ou sur le dessus du boîtier pour éviter les infiltrations d'eau.
Fixation du contrôleur au mur : Laisser un espace libre d’au moins 12 pouces au-dessus du contrôleur pour permettre de souleverle couvercle et d’effectuer un entretien.
*Thermostats de secours :Les thermostats de secours sont montrés à titre d’exemple. Utilisez suffisamment de thermostats de secours pour assurer la ventilation en cas de défaillance du contrôleur.
Coil
N.O.
N.O.COM
COM{
{
Alimentation bobine
Stage sortie
du contrôle
au panneau de distibution électriquestage entrée
Capacité des sorties variables :115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Capacité des sorties marche-arrêt :115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max.
Il est recommandé d’installer des relais externes sur les stages marche-arrêt reliés aux moteurs
Sélecteur de tension115/230 Vac
Connecteur J2
Connecteur pour le couvercle
Con
nect
eur p
our
carte
de
com
mun
icat
ion
(Com
link-
1) Smart Climate 22
Voir au verso pour lebranchement du
potentiomètreVoir au verso pour le
branchement des sondes
Thermostat de secours *(non-inclus)
Thermostat de secours* (non-inclus)
Ventilateur à vitesse variable
Ventilateur, chauffage ou brumisateur
Ventilateur à vitesse variableCharge0-10V n°1
Boîtes à fusibles : Nous recommandons d’installer une boîte à fusible sur chaque stage.
Notes :1. L’installation d’un système d’alarme est fortement recommandée afin de détecter les pertes de courant et les hautes/ basses températures.
2. Des protecteurs de surtension sont recommandés entre l’alimentation, le contrôleur et les sondes. Consulter un électricien au besoin.
3. Lors d’une alimentation 3 phases, les mêmes phases doivent être utilisées pour alimenter les ventilateurs variables et le
Voir au verso pour le branchement des
actuateurs
1 2 3 4
Sonde d’humiditérelative HS-1(Optionnel)
Sonde d’humiditéHP1, HS-100
(Ancien modèle)
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
FRSC
HÉM
A D
E BR
AN
CHEM
ENT
SMA
RT C
LIM
ATE
22
#891
-004
98RE
V 03
Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.comAP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: mtl_techsupport@agcocorp.com
REV 07
FRSCHÉMA DE BRANCHEMENT
SMART CLIMATE 22
#891-00498 REV 03
AB
GN
D
AB
GN
D
12
3
AB
GN
D
AB
GN
D
12
3
EOL
= no
n*[L
igne
PC
]
Rouge
Noir
Blindage
Con
nect
eur A
MO
DU
LE S
UR
ELIN
K*
Se
réfé
rer a
u m
anue
l dí
utili
satio
n du
m
odul
e S
urel
ink
pour
régl
er le
s ca
valie
rs d
e fin
de
ligne
(EO
L)
NO
NO
UI
FIN
DE
LIG
NE
(EO
L)
12
34
TxR
xG
LN
G
76
54
32
1O
rdin
ateu
rou
mod
em
RougeVert
Blanc
Ord
inat
eur o
u m
odem
BR
IDG
E-A
12
3
EOL
= ou
i*[L
igne
PC
]
PCG
H
PC1
PC2
FE OUT-
CO
NTR
ÔLE
UR
PR
INC
IPA
L
CA
RTE
“EN
AB
LER
”
PCG
H
PC1
PC2
FE
CA
RTE
“C
OM
LIN
K-1
”
Bra
nche
men
t de
la c
omm
unic
atio
n po
ur
A
-BO
X(o
ptio
nnel
)
Bra
nche
men
t de
la c
omm
unic
atio
npo
ur
A
gNet
(opt
ionn
el)
EOL
= ou
i[L
igne
PC
]
CO
NTR
ÔLE
UR
PR
INC
IPA
L
EOL
= ou
i[L
igne
PC
]FI
N D
E LI
GN
E (E
OL)
JAU
NE
NO
IR
RO
UG
E
POTENTIOMÉTRE {A
ctua
teur
Von
Wei
se V
-76-
115
Mot
eur 1
15 V
AC
ave
c po
tent
iom
ètre
(1, 5
ou
10 K
ohm
s, 1
0 to
urs)
BLANC
BLEU (CONTACT MOBILE)
ORANGE
N-
+G
LFI
LTR
E
TR
AN
SFO
RM
AT
EU
R18
À 3
6 V
DC
ACTU
ATEU
R
CLO
OPN
INW
INC
HR
ETU
RN
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
ACTU
ATEU
R
L1
{
GN
D
L2
( N
)AL
IMEN
ATIO
N DE
L'
ACTU
ATEU
R23
0 VA
C (1
15VA
C)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
CLO
OPN
INW
INC
HR
ETU
RN
CLO
OPN
INW
INC
HR
ETU
RN
L1
{
GN
D N
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
FERMER
OUVRIR
AL
IME
NTA
TIO
NA
CT
UA
TE
UR
115
VA
C{
L1
GN
D N
T
T
T
T
T° EXT
T
T
T
T
T° EXT
+18VAC
-18VAC
FERMER
OUVRIR
FERMER
OUVRIR
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
POTE
NTI
OM
ÉTR
E(1
, 5 o
u 10
Koh
ms,
10
tour
s)
CÂ
BLE
S B
LIN
DÉS
18AW
G
T
T
T
T
T° EXT
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
CÂ
BLE
S B
LIN
DÉS
18AW
G
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.) AC
TU
AT
EU
R V
IC J
AC
K :
MO
TE
UR
AC
LA R
ÉSIS
TAN
CE
AU
GEM
ENTE
SU
R 1
3 ET
14
EN O
UVE
RTU
RE
CLO
OPN
INW
INC
HR
ETU
RN
12
34
56
78
910
1112
13
AB
CD
EF
GH
IJ
KL
M
14
N
15
O
ROUGE
NOIR
L1
{
GN
D(
N )
BLA
NC
VER
T
T
T
T
T
T° EXT
SONDE DE T° INTÉRIEURE #1
SONDE DE T° INTÉRIEURE #2 (OPT.)
SONDE DE T° INTÉRIEURE #3 (OPT.)
SONDE DE T° INTÉRIEURE #4 (OPT.)
SONDE DE T° EXTÉRIEURE (OPT.)
CO
MP
TE
UR
D
’EA
U(O
PTIO
NN
EL)
JAUNE (CONTACT MOBILE)
NOIR
ROUGE
ALIM
ENTA
TION
AC
TUAT
EUR
115
VAC
ACTU
ATEU
R VI
C JA
CKav
ec p
oten
tiom
ètre
(1, 5
OU
10 K
ohm
s, 1
0 To
urs)
IMPO
RTA
NT
:B
RA
NC
HER
CO
RR
ECTE
MEN
TLE
BO
RN
IER
Â
L’A
CTU
ATEU
RW
INC
H
RET
UR
N
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
 L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
IMPO
RTA
NT
:B
RA
NC
HER
C
OR
REC
TEM
ENT
LE B
OR
NIE
R
À L
’AC
TUAT
EUR
WIN
CH
R
ETU
RN
CÂ
BLE
S B
LIN
DÉS
18AW
G
Actuateur (treuil) : sortie d’ouverture et de fermeture, 120VAC(0.17HP 124W), 240VAC (0.5HP 373W), 30 VDC 5A Ind.
Compteur d’eau :La sortie du compteur d’eau doit être un contact sec et ne doit pas pulser plus rapidement que 60 fois la seconde (60 Hz).Un câble de calibre 22/12 AWG ne dépassant pas 2000 pieds (0,6 km) peut être utilisé pour raccorder le compteur d’eau. Ne pas utiliser un câble plus long que 2000 pieds même si le câble utilisé est plus gros.Ne pas faire courir le câble du compteur d’eau à l’extérieur du bâtiment !
230 V
CLO OPN INWINCHRETURN
4 5 6 7 8 9 10 11 12 13 14 15
D E F G H I J K L M N O
PC1
PC2
Vers
r Brid
ge-A
OU
T +
OU
T -
G 1
{ AlarmeNCC
NO
{
0-10V +
0-10V -PMV-1stage 2(Opt.)
G 1
1 2 3
A B C
Vers
bor
nier
n°8
Vers
bor
nier
n°9
Vers
bor
nier
n°1
0
0-10V +
0-10V -
STAGE 5 STAGE 4 STAGE 3 V1 IN1 V2 IN2 L2/N L
12"
ContrôleurAlimentation230 Vac (115 Vac)
Stage 3 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 4 Sortie marche-arrêtAlimentation230 Vac (115 Vac)
Stage 1 Sortie variableAlimentation230 Vac (115 Vac)
Stage 2Sortie variableAlimentation230 Vac (115 Vac)PMV-1
stage 1 (Opt.)
Charge0-10V n°2
Sonde depression statique
Dwyer Gauge(Opt.)
GND
L1
L2 (N)
Marche-arrêt
GND
L1
L2 (N)
Ventilateur, chauffage ou brumisateur
Marche-arrêt
GND
L1
L2 (N)
GND
L1
L2 (N)
GND
L1
L2 (N)
Entrée des câbles: Passer tous les câbles sous le boîtier. Ne pas percer de trous sur les côtés ou sur le dessus du boîtier pour éviter les infiltrations d'eau.
Fixation du contrôleur au mur : Laisser un espace libre d’au moins 12 pouces au-dessus du contrôleur pour permettre de souleverle couvercle et d’effectuer un entretien.
*Thermostats de secours :Les thermostats de secours sont montrés à titre d’exemple. Utilisez suffisamment de thermostats de secours pour assurer la ventilation en cas de défaillance du contrôleur.
Coil
N.O.
N.O.COM
COM{
{
Alimentation bobine
Stage sortie
du contrôle
au panneau de distibution électriquestage entrée
Capacité des sorties variables :115VAC 1/2HP (373W), 230VAC 1.5HP (1120W), 10 Amp Max.
Capacité des sorties marche-arrêt :115VAC 1/4HP (187W), 230VAC 1/2HP (373W), 7.5 Amp Res. Max.
Il est recommandé d’installer des relais externes sur les stages marche-arrêt reliés aux moteurs
Sélecteur de tension115/230 Vac
Connecteur J2
Connecteur pour le couvercle
Con
nect
eur p
our
carte
de
com
mun
icat
ion
(Com
link-
1) Smart Climate 22
Voir au verso pour lebranchement du
potentiomètreVoir au verso pour le
branchement des sondes
Thermostat de secours *(non-inclus)
Thermostat de secours* (non-inclus)
Ventilateur à vitesse variable
Ventilateur, chauffage ou brumisateur
Ventilateur à vitesse variableCharge0-10V n°1
Boîtes à fusibles : Nous recommandons d’installer une boîte à fusible sur chaque stage.
Notes :1. L’installation d’un système d’alarme est fortement recommandée afin de détecter les pertes de courant et les hautes/ basses températures.
2. Des protecteurs de surtension sont recommandés entre l’alimentation, le contrôleur et les sondes. Consulter un électricien au besoin.
3. Lors d’une alimentation 3 phases, les mêmes phases doivent être utilisées pour alimenter les ventilateurs variables et le
Voir au verso pour le branchement des
actuateurs
1 2 3 4
Sonde d’humiditérelative HS-1(Optionnel)
Sonde d’humiditéHP1, HS-100
(Ancien modèle)
top related