Rectangular Duct FansRK • RKC
web-version
2
The fan company
DEVELOPMENT
C.A. Östberg in Avesta is one ofEurope´s largest manufacturer of fansfor the ventilation market. Productionstarted in 1981. New thinking is animportant ingredient in the company´sbusiness concept, which has resulted incontinuous development of products,quality, production and turnover.
As long ago as the 1970´s Hans Östberg
invented the world´s first circular inline
centrifugal duct fan with an external rotor
induction motor. Another revolutionary
invention, the rectangular duct fan, came
a few years later. Inexpensive, versatile
and easy to fit, the design revolutionised
the market in its field.
Continuous product development has
ensured that the products maintain the
highest quality on the market.
The company produces some 300 000 fans
annually and employs 140 people in a
plant covering 10000 m2.
The company is certified according to
ISO 9001 and ISO 14001.
IN THE MIND OF AN INVENTOR
33
RATIONALPRODUCTIONAND HIGHPROPORTIONFOR EXPORT
IN A CLASS OF THEIR OWN
The assembly line forrectangular duct fansat C.A. Östberg.
C.A. Östberg has probably Sweden´s highest proportion of production exported in the
ventilation industry. We export as much as 85 % of what we make to customers all over the
world. We believe our success, both at home and abroad, is due to the high quality and
reliability of our produts. Long series and rational production methods mean that we can
offer the market competitive prices.
Fans are supplied fully-wired with built-in capacitor and in asealed installation unit.
Ball-bearing-mounted external rotor induction motors of thehighest quality. Excellent cooling allows 0-100 % speed control.
Guide plate for higher pressure and flow.
Housings are made of strong galvanised steel.
Swing-out design.
RK Duct fan, for rectangular ducts
RKC Duct fan, for cylindrical ducts
4
Explanations to sound dataThe sound data have been compiled by means of sound measurement methods as follows:Pressure and flow: ISO 5801Determination of acoustic sound level in duct: ISO 5136Determination of acoustic sound level in reverberation room: ISO 3741
DesignationsLWA tot: Total A-weighted sound power level dB(A) (ref 10-12 W)=the sum of the sound power level in the octave ranges. LWA: A-weighted sound power level in octave range dB(A) (ref 10-12 W).LpA: A-weighted sound pressure level in dB(A) according to normed A-weightening correction and relating to an effective absorption area of 20 m2 with half spherical translation at a distance of 3 meters.
RK and RKC duct fans have straight throughflow with connections for either rec-tangular or cylindrical ducts. The fans have a rigid housing of galvanised steel. Theyare compact, high-capacity fans, operate quietly and can be built-in in any position.RK fans have forward or backward-curved impellers (see table). They are designedto cope with high pressures and long ducts with a minimum of noise. The motorsare maintenance-free, why the only service required is cleaning the impellers.Motors with impellers can be swung out for inspection and cleaning (swing-out).
All fans are supplied fully-wired and ready to fit in a sealed installation unit. Theyare moisture-proofed and approved for use in outdoor applications. The duct fansare not recommended for transporting grinding dust, soot, flour or similar.All fans are fitted with a built-in thermo-contact protector (see page 5).
• 11 sizes, in approx. 50 different executions.• Rectangular or circular connection.• Reliable, maintence-free ballbearing-mounted external rotor induction
motor of the very highest quality.• High pressure.• Minimum of noise.• Speed-controllable from 0-100 %.• Can be built-in in any position.• Any voltage and frequency quoted on request.• All models are fitted with an approved thermo-contact protector as
standard.• RK and RKC can be supplied with ready-fitted thermo-contact leads, e.g. for
alarm function.• All RK fans are supplied with an universal guide rail for easy fitting to rectangular
duct.
The sides can be supplied separately for connecting RK fans to RKC cylindrical ducts.
Instructions for maintenance of RK(C) The duct fan is fitted with an asynchronus motor of external rotortype with enclosed maintenance-freeballbearings. Single-phase motors are equipped with an approved thermo-contact protector with automa-tic reset. 3-phase motors are ready-wired with thermo-contact leads. These must be connected over amotorprotector, or if speed control is used, over a thermo-contact relay, fitted as standard in our 3-phasetransformers. The thermo-contact breaks the current if the temperature in the motor windings becomesexcessive. In single-phase motors the thermo-contact is reset automatically when the temperature in themotor windings falls to the permitted level. In 3-phase motors, the thermo-contact is reset as follows:Turn off the mains power. Wait until the motor has cooled. Reconnect the mains power.The fan is intended for continuous operation and can be speed-controlled by voltage variation using exter-nal equipment. It is not designed for transporting explosive gases, grinding dust, soot, flour or similar.
Electrical installation:The fan may only be installed by a qualified electrican. All RK(C) fans are supplied fully-wired and ready tofit in a sealed installation unit.1. Check that the voltage, frequency, cycles etc. of the mains supply correspond with the
specifcations on the fan´s ID plate.2. All electrical wiring and connections must be carried out in compliance with your national safety
regulations.3. The fan must be earthed.
Installation and fitting:
The fan can be installed in any position. For the maximum temperature of transported air, refer to thediagram of the fan. The fan must be fitted to a duct or fitted with a protective grille.
Care and maintenance:The only maintenance required is cleaning. We recommend inspection of the impeller every six months ifthe fan is operated continuously. Before cleaning: Disconnent from the mains and block the mains switch.Wait until the motor and impeller have stopped rotating. Care must be taken during dismantling and cleaning so as not to disturb the fan´s balance. Strong deter-gents or cleaning agents must not be used for cleaning the fan. Internal insulation may be wiped clean witha damp cloth. Sharp or rotating tools must not be used as these may damage outer surfaces.
In case of breakdown: 1. Check that mains power is reaching the fan.2. Disconnect from the mains and ensure that the impeller is not blocked.3. Check the thermo-contact according to the description above. If the thermo-contact has
activated, the cause of overheating should be determined to prevent the same fault recurring.4. Check that the capacitor is connected (single-phase, refer to the wiring diagram).5. If the fault persist, change the capacitor. 6. If these steps do not help, contact your supplier.7. Should the fan need to be returned to us, the impeller must be cleaned and motor wiring
undamaged, and a written description of the fault enclosed.
5
Yellow-green
Black
Blue
Brown
N
LFAN
WIRING DIAGRAM (WD) No 1
Yellow-green
W 1
V 2
V 1
U 2
U 1
W 2
T W
T W
L 3
L 2
L 1FAN
WIRING DIAGRAM (WD) No 4
Black
Brown
Blue
White TW
White TW
Yellow-green
N
LFAN
WIRING DIAGRAM (WD) No 5
We preserve the right to changes without further notice.Sound data explanations; see page 4
h
b
o9
o
d
c
g
d c e
f
a
6
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular Circular
RK 300x150 C1 RKC 160 C1 1 230 0,083 0,36 2300 B 300 150 30 375 160 192 342 148 213 7 1RK 400x200 A1 RKC 200 A1 1 230 0,107 0,47 2300 B 400 200 40 500 200 244 444 214 264 13 1
RK 400x200 B1 RKC 200 B1 1 230 0,158 0,69 2400 B 400 200 40 500 200 244 444 214 264 13 1
RK 400x200 E1 RKC 200 E1 1 230 0,188 0,83 2400 B 400 200 40 500 200 244 444 214 264 14 1
Technical data
Sound data
** B=backward curved impellar; F=forward curved impellar
* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
Type of fan63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 300x150 C1 RKC 160 C1 0,063Inlet duct 61 68 43 52 60 66 57 54 48 36
250Outlet duct 63 70 47 53 62 66 65 59 56 40
Fan room 51 58 30 30 44 55 51 49 47 35
RK 400x200 A1 RKC 200 A1 0,12Inlet duct 66 73 50 56 66 71 65 60 57 45
250Outlet duct 68 75 54 59 67 73 68 64 60 47
Fan room 55 62 37 38 52 61 53 52 47 37
RK 400x200 B1 RKC 200 B1 0,16Inlet duct 66 73 53 59 65 70 66 62 58 49
340Outlet duct 69 76 57 60 67 73 69 67 62 52
Fan room 56 63 39 43 51 62 53 51 46 41
RK 400x200 E1 RKC 200 E1 0,18Inlet duct 68 75 56 62 68 71 67 62 59 50
340Outlet duct 72 79 59 64 71 76 71 70 64 53
Fan room 59 66 44 40 49 54 52 50 46 40
Flow m3/sTotal pressure
LpAdB (A)
LwAtot
LwA
7
5 4 3 2 1
1-phase V 230 165 135 110 80
RK 400x200 B1/RKC 200 B1
RK 300x150 C1/RKC 160 C1 RK 400x200 A1/RKC 200 A1
RK 400x200 E1/RKC 200 E1
Tot.
pres
sure
Pa
kW kW
kW kW
m3/h
m3/sTo
t. pr
essu
re P
a
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Pos. ontransfomer/curve
5
We preserve the right to changes without further notice.Explanations to sound data, see page 4
Sound dataType of fan
63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 400x200 C1 RKC 200 C1 0,18Inlet duct 61 68 60 60 61 62 61 53 53 43
213Outlet duct 63 70 57 60 62 64 65 60 59 50
Fan room 49 56 39 44 48 52 51 46 42 36
RK 400x200 C3 RKC 200 C3 0,22Inlet duct 60 67 54 59 61 63 58 55 53 42
225Outlet duct 64 71 54 59 63 66 66 62 60 50
Fan room 49 56 34 45 48 50 51 47 43 37
RK 500x250 C1 RKC 250 C1 0,28Inlet duct 67 74 55 66 68 68 66 66 61 51
300Outlet duct 71 78 55 67 69 75 68 70 64 54
Fan room 58 65 39 45 57 61 57 58 55 46
LpAdB (A)
LwAtot
Flow m3/sTotal pressure
LwA
h
b
o9
o
d
c
g
d c e
f
a
8
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircularRK 400x200 C1 RKC 200 C1 1 230 0,206 0,90 1200 F 400 200 40 502 200 244 444 214 264 11 1
RK 400x200 C3 RKC 200 C3 3 400 0,290 0,61 1300 F 400 200 40 502 200 244 444 214 264 13 4
RK 500x250 C1 RKC 250 C1 1 230 0,284 1,24 2400 B 500 250 40 600 250 294 544 148 314 16 1
Technical data
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
9
5 4 3 2 1
1-phase V 230 165 135 110 80
3-phase V 400 240 185 145 95
RK 500x250 C1/RKC 250 C1
RK 400x200 C1/RKC 200 C1 RK 400x200 C3/RKC 200 C3
5
40°C
Pos. ontransfomer/curve
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kW
kW
We preserve the right to changes without further notice.Sound data explanations; see page 4
h
b
o9
o
d
c
g
d c e
f
a
10
Sound dataType of fan
63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 500x250 B1 RKC 250 B1 0,18Inlet duct 53 60 47 53 53 54 50 51 47 35
137Outlet duct 57 64 47 50 55 59 58 57 54 44
Fan room 44 51 34 42 43 45 44 41 39 33
RK 500x250 D1 RKC 250 D1 0,28Inlet duct 63 70 56 62 64 61 60 62 59 50
303Outlet duct 67 74 56 63 65 66 68 68 66 58
Fan room 53 60 39 50 54 52 52 51 49 42
RK 500x250 D3 RKC 250 D3 0,28Inlet duct 63 70 55 62 63 62 61 63 59 50
303Outlet duct 68 75 57 62 66 67 69 69 66 58
Fan room 54 61 38 46 56 54 54 52 50 43
LpAdB (A)
LwAtot
Flow m3/sTotal pressure
LwA
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircularRK 500x250 B1 RKC 250 B1 1 230 0,180 0,86 850 F 500 250 40 532 250 294 544 148 314 16 5
RK 500x250 D1 RKC 250 D1 1 230 0,470 2,15 1300 F 500 250 40 532 250 294 544 148 314 17 5
RK 500x250 D3 RKC 250 D3 3 400 0,560 1,10 1310 F 500 250 40 532 250 294 544 148 314 17 4
Technical data
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
11
5 4 3 2 1
1-phase V 230 165 135 110 80
3-phase V 400 240 185 145 95
RK 500x250 D3/RKC 250 D3
RK 500x250 B1/RKC 250 B1 RK 500x250 D1/RKC 250 D1
Pos. ontransfomer/curve
Tot.
pres
sure
Pa
m3/h
m3/sTo
t. pr
essu
re P
a
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kW
kW
h
b
o9
o
d
c
g
d c e
f
a
We preserve the right to changes without further notice.Sound data explanations; see page 4
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
12
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular Circular
RK 500x300 A1 RKC 315 A1 1 230 0,250 1,22 900 F 500 300 40 562 315 344 544 192 364 19 5
RK 500x300 B1 RKC 315 B1 1 230 0,630 3,00 1250 F 500 300 40 562 315 344 544 192 364 21 5
RK 500x300 B3 RKC 315 B3 3 400 0,850 1,60 1280 F 500 300 40 562 315 344 544 192 364 21 4
Technical data
Sound dataType of fan
63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 500x300 A1 RKC 315 A1 0,30Inlet duct 57 64 53 59 56 57 54 57 54 42
170Outlet duct 63 70 52 56 59 66 62 63 60 47
Fan room 47 54 33 40 47 47 49 45 41 36
RK 500x300 B1 RKC 315 B1 0,35Inlet duct 66 73 61 65 65 63 64 67 64 56
380Outlet duct 71 78 60 64 68 71 74 70 70 60
Fan room 56 63 38 52 56 55 58 54 51 46
RK 500x300 B3 RKC 315 B3 0,44Inlet duct 67 74 61 65 66 64 67 67 65 57
385Outlet duct 72 79 59 66 69 71 75 72 71 61
Fan room 57 64 45 47 58 56 59 56 53 47
LpAdB (A)
LwAtot
Flow m3/sTotal pressure
LwA
5 4 3 2 1
1-phase V 230 165 135 110 80
3-phase V 400 240 185 145 95
Pos. ontransformer/curve
13
RK 500x300 B3/RKC 315 B3
RK 500x300 A1/RKC 315 A1 RK 500x300 B1/RKC 315 B1To
t. pr
essu
re P
a
m3/h
m3/sTo
t. pr
essu
re P
a
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kW
kW
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
We preserve the right to changes without further notice.Sound data explanations; see page 4
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular Circular
RK 600x300 D1 RKC 315 D1 1 230 0,42 2,00 850 F 600 300 40 642 315 344 644 214 364 30 5
RK 600x300 D3 RKC 315 D3 3 400 0,50 0,85 750 F 600 300 40 642 315 344 644 214 364 30 4
RK 600x300 F1 RKC 315 F1 1 230 1,20 5,60 1240 F 600 300 40 642 315 344 644 214 364 32 5
RK 600x300 F3 RKC 315 F3 3 400 1,44 2,80 1300 F 600 300 40 642 315 344 644 214 364 32 4
Technical data
Type of fan63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 600x300 D1 RKC 315 D1 0,29Inlet duct 59 66 55 58 61 58 56 55 53 41
220Outlet duct 63 70 56 58 63 64 62 61 61 48
Fan room 51 58 38 49 51 51 53 46 47 39
RK 600x300 D3 RKC 315 D3 0,35Inlet duct 61 68 58 59 61 61 60 62 58 49
225Outlet duct 65 72 57 60 62 67 65 67 64 52
Fan room 52 59 38 45 52 53 54 48 48 40
RK 600x300 F1 RKC 315 F1 0,46Inlet duct 70 77 66 69 69 68 69 71 67 58
445Outlet duct 73 80 64 68 71 73 74 74 72 63
Fan room 58 65 49 53 59 56 62 57 52 45
RK 600x300 F3 RKC 315 F3 0,47Inlet duct 72 79 66 70 70 70 71 73 69 60
500Outlet duct 75 82 66 69 73 74 75 76 74 65
Fan room 60 67 48 54 61 57 62 59 55 48
Flow m3/sTotal pressure
Sound dataLpA
dB (A)LwAtot
LwA
h
b
o9
o
d
c
g
d c e
f
a
14
15
5 4 3 2 1
1-phase V 230 165 135 110 80
3-phase V 400 240 185 145 95
RK 600x300 F1/RKC 315 F1
RK 600x300 D1/RKC 315 D1 RK 600x300 D3/RKC 315 D3
RK 600x300 F3/RKC 315 F3
Pos. ontransformer/curve
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kWkWkW
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
We preserve the right to changes without further notice.Sound data explanations; see page 4
Type of fan63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 600x350 C1 RKC 355 C1 0,45Inlet duct 62 69 55 64 61 60 61 60 57 47
297Outlet duct 65 72 52 60 65 66 64 63 62 49
Fan room 52 59 43 54 55 51 50 46 44 36
RK 600x350 C3 RKC 355 C3 0,45Inlet duct 62 69 55 62 59 60 63 61 58 47
297Outlet duct 65 72 54 61 63 66 65 65 61 49
Fan room 51 58 43 48 51 53 51 49 44 37
RK 600x350 E1 RKC 355 E1 0,51Inlet duct 72 79 65 75 69 66 70 70 66 58
622Outlet duct 73 80 61 70 71 72 76 73 71 61
Fan room 58 65 50 58 57 57 60 56 52 46
RK 600x350 E3 RKC 355 E3 0,61Inlet duct 71 78 66 72 68 67 73 72 67 58
623Outlet duct 75 82 62 70 71 73 78 75 72 62
Fan room 59 66 49 57 56 57 61 58 55 47
Flow m3/sTotal pressure
Sound data
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircularRK 600x350 C1 RKC 355 C1 1 230 0,75 4,2 850 F 600 350 45 717 355 394 644 252 414 38 5
RK 600x350 C3 RKC 355 C3 3 400 0,90 1,9 870 F 600 350 45 717 355 394 644 252 414 38 4
RK 600x350 E1 RKC 355 E1 1 230 1,78 8,0 1200 F 600 350 45 717 355 394 644 252 414 42 5
RK 600x350 E3 RKC 355 E3 3 400 2,13 4,3 1250 F 600 350 45 717 355 394 644 252 414 42 4
LpAdB (A)
LwAtot
LwA
Technical data
h
b
o9
o
d
c
g
d c e
f
a
16
17
5 4 3 2 1
1-phase V 230 165 135 110 80
3-phase V 400 240 185 145 95
RK 600x350 E1/RKC 355 E1
RK 600x350 C3/RKC 355 C3
RK 600x350 E3/RKC 355 E3
Pos. ontransformer/curve
RK 600x350 C1/RKC 355 C1To
t. pr
essu
re P
am3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW 2 kWkWkW
h
b
o9
o
d
c
g
d c e
f
a
18
Type of fan63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 700x400 A3 RKC 400 A3 0,55Inlet duct 58 65 53 57 58 58 57 58 56 43
220Outlet duct 65 72 56 59 64 66 63 64 62 49
Fan room 51 58 36 42 51 53 51 49 47 37
RK 700x400 B3 RKC 400 B3 0,75 Inlet duct 66 73 61 64 65 64 65 67 63 53
390Outlet duct 71 78 63 66 70 72 72 71 69 58
Fan room 57 64 49 49 56 57 59 57 55 45
RK 700x400 D3 RKC 400 D3 0,85Inlet duct 74 81 66 71 73 70 75 76 71 62
795Outlet duct 79 86 67 74 75 76 80 80 77 67
Fan room 66 73 54 57 65 67 66 64 62 54
LpAdB (A)
LwAtot
Flow m3/sTotal pressure
LwA
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircularRK 700x400 A3 RKC 400 A3 3 400 0,90 2,0 690 F 700 400 45 787 400 444 744 306 468 47 4
RK 700x400 B3 RKC 400 B3 3 400 1,50 2,7 870 F 700 400 45 787 400 444 744 306 468 54 4
RK 700x400 D3 RKC 400 D3 3 400 3,65 6,6 1300 F 700 400 45 787 400 444 744 306 468 60 4
Technical data
We preserve the right to changes without further notice.Sound data explanations; see page 4
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
Sound data
19
5 4 3 2 1
3-phase V 400 240 185 145 95
RK 700x400 D3/RKC 400 D3
RK 700x400 A3/RKC 400 A3 RK 700x400 B3/RKC 400 B3
Pos. ontransformer/curve
Tot.
pres
sure
Pa
m3/h
m3/sTo
t. pr
essu
re P
a
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kW
kW
h
b
o9
o
d
c
g
d c e
f
a
20
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircularRK 800x500 C3 RKC 500 C3 3 400 1,25 2,8 690 F 800 500 50 882 500 544 844 306 568 70 4
RK 800x500 E3 RKC 500 E3 3 400 2,80 5,25 870 F 800 500 50 882 500 544 844 306 568 78 4
RK 800x500 F3 RKC 500 F3 3 400 5,20 8,9 1390 F 800 500 50 882 500 544 844 306 568 81 4
Technical data
Sound dataType of fan
63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 800x500 C3 RKC 500 C3 0,76Inlet duct 61 68 55 58 60 59 62 62 58 44
270Outlet duct 66 73 57 61 65 68 66 66 63 48
Fan room 54 61 46 48 54 56 55 52 46 37
RK 800x500 E3 RKC 500 E3 1,00Inlet duct 69 76 64 67 67 66 71 69 66 56
475Outlet duct 75 82 66 68 72 76 75 75 72 61
Fan room 60 67 52 55 59 62 62 59 55 46
RK 800x500 F3 RKC 500 F3 1,10Inlet duct 79 86 70 75 75 72 82 80 75 66
1050Outlet duct 83 90 70 78 80 82 85 85 81 70
Fan room 68 75 59 64 65 69 70 68 63 54
LpAdB (A)
LwAtot
Flow m3/sTotal pressure
LwA
We preserve the right to changes without further notice.Sound data explanations; see page 4
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
21
RK 800x500 F3/RKC 500 F3
RK 800x500 C3/RKC 500 C3 RK 800x500 E3/RKC 500 E3
5 4 3 2 1
3-phase V 400 240 185 145 95
Pos. on transformer/curve
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kW kW
kW
h
b
o9
o
d
c
g
d c e
f
a
22
Sound dataType of fan
63 125 250 500 1k 2k 4k 8kRectangular Circular
RK 1000x500 G3 RKC 500 G3 1,0Inlet duct 65 72 61 66 63 62 64 65 61 49
365Outlet duct 71 78 63 67 68 72 71 72 67 54
Fan room 58 65 49 53 56 62 56 53 49 41
RK 1000x500 H3 RKC 500 H3 1,13Inlet duct 70 77 66 68 67 67 70 72 66 58
635Outlet duct 76 83 69 71 72 76 77 78 73 63
Fan room 62 69 55 59 59 65 63 61 56 49
LpAdB (A)
LwAtot
Flöde m3/sTotaltryck
LwA
Type of fan Phase V* kW A Rpm Impellar** a b c d Ø e f g h Kg WDRectangular CircuklarRK 1000x500 G3 RKC 500 G3 3 400 1,70 5,25 680 F 1000 500 50 982 500 544 1044 294 568 90 4
RK 1000x500 H3 RKC 500 H3 3 400 4,00 7,0 870 F 1000 500 50 982 500 544 1044 294 568 90 4
Technical data
We preserve the right to changes without further notice.Sound data explanations; see page 4
** B=backward curved impellar; F=forward curved impellar* All types as standard for 50 Hz. Other voltages and frequences can be quoted on request.
23
RK 1000x500 H3/RKC 500 H3
RK 1000x500 G3/RKC 500 G3
5 4 3 2 1
3-phase V 400 240 185 145 95
Pos. on transformer/curve
Tot.
pres
sure
Pa
m3/h
m3/s
Tot.
pres
sure
Pa
m3/h
m3/s
kWkW
ed b
y Da
la Print
Med
ia, B
orlän
ge, S
wede
n. 02
06
AB C.A. ÖSTBERGINDUSTRIGATAN 2SE-774 35 AVESTASWEDEN