Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7Ti

tle S

heet

Cons

truc

tion

Docu

men

ts

T-0.0

5/23

/16

CHK

-/-

Regi

onal

Dire

ctor

Building Information

Project Data

Project Description

Opportunities for Learning

Sheet Index

Municipal Code: Title 15: Buildings and ConstructionAPN : 2810-043-070Existing Occupancy: BExisting Zone Commercial/IndustrialType of Construction: III BProposed Occupancy: ETotal Building: 10,910 sq.ft.Area of Tenant Improvement: 6,578 sq.ft.

Owner:Sharon ShifflettKensington Del Rancho LLC17542 EAST 17TH STREETTUSTIN, CA 92780661-295-2050Email: xxxxxxxxx

Tenant:Lupine Construction & Development on behalf of Opportunities for Learning320 N. Halstead, Suite 105Pasadena, Ca. 91107

Miki Stewart, Project ManagerMobile: (626) 673-3933E:Mail: mstewart@lupineproperties.com

Architect:Yu-Ngok Lo, YNL ArchitectsMobile:(310) 980-8981E:Mail: ynlarchitects@gmail.com

Structural Engineer:Mike Houshmand, PE.GOUVIS ENGINEERING CONSULTING GROUP, INC.4400 Campus Drive, Newport Beach, CA 92660Mobile: (949) 752-1612, ext 226

1. CONTRACTOR SHALL PERFORM ALL DEMOLITION WORK WHERENECESSARY TO COMPLETE FULL SCOPE OF WORK.

2. CONTRACTOR SHALL BUILD WALLS IN ACCORDANCE TOCONSTRUCTION DOCUMENTS, (IE; FRAMING, DRYWALL,INSULATION, AS NOTED.

3. CONTRACTOR SHALL INSTALL DOORS, FRAMING, ANDHARDWARE AS PER SPECIFICATIONS. DOORS SHALL BE REUSEDFROM EXISTING DEMOLISHED WALLS.

4. CONTRACTOR SHALL INSTALL WINDOWS AND FRAMES PERSPECIFICATIONS. WINDOWS SHALL BE REUSED FROM EXISTINGDEMOLISHED WALLS.

5. CONTRACTOR SHALL INSTALL ALL ELECTRICAL CONDUIT INWALLS AND ABOVE CEILING LINE FOR LOW VOLTAGEEQUIPMENT IN THE SPECIFIED LOCATIONS.

6. CONTRACTOR SHALL INSTALL AND OR VERIFY HIGH VOLTAGEELECTRICAL OUTLETS.

7. CONTRACTOR SHALL INSTALL LIGHT SWITCHES IN NEWLYCONSTRUCTED WALLS AS REQUIRED TO MEET ADA AND CDCSPECIFICATIONS.

8. CONTRACTOR SHALL INSTALL FLOORING AND BASE PERSPECIFICATIONS.

9. CONTRACTOR SHALL RELOCATE HVAC SUPPLY AND RETURNREGISTERS AS REQUIRED AND ACHIEVE AN AIR BALANCETHROUGHOUT TENANT SPACE.

10. CONTRACTOR SHALL PAINT SPACE WITHIN TENANTIMPROVEMENT AS PER SPECIFICATIONS.

11. CONTRACTOR SHALL REPLACE ALL DAMAGED CEILING TILESAND REPLACE OR MEND ANY DAMAGED T-BAR CEILING SYSTEMWITHIN TENANT IMPROVEMENT AREA OF WORK.

12. CONTRACTOR SHALL SHALL COMPLY WITH ALL ADA AND TITLE24 SPECIFICATIONS, WITH REGARDS TO ANY ADDITIONS ORSUBSTITUTIONS, REQUESTED WITHIN THE SCOPE OF WORK.

13. CONTRACTOR SHALL NOT PROCEED WITH ANY UNAUTHORIZEDWORK ON THIS TENANT IMPROVEMENT PROJECT WITHOUTNOTIFICATION AND AUTHORIZATION FROM LUPINE PROPERTIES.

Architectural General NotesOpportunities for Learning (OFL), a public charter school program, is hoping to lease 6,578 square foot existing commercial space at 27616 Newhall Ranch Rd. Ste. A10-15-25, Valencia, CA 91355

to be used as an independent study learning center. The OFL program is a publicly funded charter school compliant with ADA regulations to serve non ambulatory students in grades 7‐12.

As a registered active charter school with the California Department of Education (CDE), Opportunities for Learning is accredited by the Western Association of Schools and Colleges (WASC). Students whoattend OFL earn course credits and are enrolled at OFL until either they transfer back to a traditional school or graduate from OFL with a high school diploma.

OFL students attend school for two 1.5 hour appointments per week. During these appointments, students receive their curriculum from their teachers. Additionally, students are able to attend smallgroup instruction classes, take tests, meet with a college advisors, and, if needed, receive additional instruction from a tutor. Students are required to study and complete coursework independently for 4‐6hours each day. Due to the independent study model, OFL does not provide transportation, food service, gymnasiums, or playground facilities to students at each learning center. Additionally, a majority ofthe students utilize public transportation to commute to and from the center. This greatly reduces the parking load required for each center. Currently, many centers throughout Southern Californiaoperate with minimal parking without any adverse effects to attendance or the surrounding area.

Projected staff (6 teachers with 1 support staff), current students, (Average Attendance) is 307 students projected per year .Each teacher serves a maximum of 5 students per 1.5 hour appointment, with a maximum of 45 at any one time. At the proposed center, 5 teachers and 1 support staff, for a total of 5 staff members, areexpected to serve approximately 45 students per 1.5 hours. Typical student appointments are at 9am, 10:30, 1 and 2:30.

OFL centers are open Monday - Friday from 8am - 5pm, closed for lunch from 12pm‐1pm, and closed most Saturdays and all Sundays. Additionally, OFL offers Saturday school 4 times a year for SAT andCASHEE prep testing from 9am - 12pm.

OFL currently operates several learning centers in the San Bernardino, Los Angeles and Sacramento counties of California, the vast majority of which are in Los Angeles County. Graduating students willreceive an accredited diploma, which would be eligible for attendance at community colleges, technical school, and 4 year universities. OFL schools have demonstrated high levels of success with itsstudent population; creating educated and respectful members of the greater community.

Legal DescriptionREAL PROPERTY IN THE CITY OF VALENCIA, COUNTY OF LOS ANGELES, STATE OFCALIFORNIA, described as follows:

TR=52111 POR OF LOTS 12 AND 13

5/23

/16

-/-

-/-

Vicinity Map (NTS)

1. GENERAL NOTES PERTAIN TO ALL DRAWINGS.2. ALL INTERIOR DIMENSIONS ARE TO FACE OF FINISHED WALL OR CENTERLINE OF COLUMN, UNLESS OTHERWISE NOTED.3. PROVIDE ALL METAL BLOCKING AS REQUIRED FOR THE ATTACHMENT OF MISCELLANEOUS EQUIPMENT INCLUDING BUT NOT LIMIT TO, TOILET

ACCESSORIES, DOOR HARDWARE, ELECTRICAL DEVICES, EQUIPMENT INDICATED, GRAB BARS, HANDRAILS, AND CASEWORK, 16 GA. GALVANIZEDSHEET METAL CAN BE USED AS BLOCKING.

4. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF DOORS.5. ALL NEW DOORS FRAMES ARE TO BE 4” FROM ADJUDICATE FINISHED WALL SURFACE AT DOOR HINGE U.N.O. DIMENSION FOR OPENINGS WITH

DOORS ARE TO FACE OF DOOR JAMB, DIMENSION FOR OPENINGS WITHOUT DOORS ARE TO FACE OF WALL.6. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AS RECOMMENDED BY WALLBOARD MANUFACTURER, WITH SHOP DRAWINGS, AND

COORDINATE LOCATION WITH ARCHITECT. (APPROX. 30’ O.C.)7. ALL CUTTING AND PATCHING AS A RESULT OF DEMOLITION AND NEW CONSTRUCTION SHALL BE PERFORMED IN A WORKMANLIKE MANNER,

AND SHALL MATCH IN COLOR, SHAPE, SIZE & TEXTURE ADJACENT AND/OR CONTIGUOUS FINISHED SURFACES. PAINT ALL CUT AND PATCHEDSURFACES AS SPECIFIED.

8. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS & CEILINGS IN AREAS INDICATED ON ROOM FINISH SCHEDULE, PAINT BEHIND ALLMOVEABLE ITEMS AND ADJACENT TO SURFACES RECEIVING PAINT AND RELOCATED ITEMS.

9. ALL PRODUCTS UTILIZED IN THIS CONSTRUCTION SHALL BE ASBESTOS FREE.10. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR CLEANING AND DISPOSAL REQUIREMENTS.11. THE CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND AS

PERTINENT TO THE INTENT OF THESE DRAWINGS, ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERPRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY, THE CONTRACTOR SHALL BE RESPONSIBLEFOR ALL COSTS ASSOCIATED WITH OR CAUSED BY FAILURE TO COMPLY WITH THE REQUIREMENTS.

12. THE CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE WORK, EVEN THOSE AREAS DESIGNATED TO BEPROVIDED BY OTHERS, THE FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OFTHE DRAWINGS AND ALL SECTIONS OF THE SPECIFICATIONS, FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR ANDCOGNIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS,ASSEMBLIES, OR SERVICE INDICATED IN THE CONTRACT DOCUMENT.

13. NOTHING IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH OTHER TRADES, OR WAIVE THE

CONTRACTORS RESPONSIBLY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, OR WAIVETHE CONTRACTORS RESPONSIBILITY TO ALERT THE PROJECT MANAGER/DESIGNER TO DISCREPANCIES CONTAINED THEREIN.

14. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY THAT THE WORK WILL NOT PROHIBIT COMPETITION OFTHE PROJECT AS INTENDED IN THESES CONTACT DOCUMENT, ANY QUESTIONS SHALL BE PROMPTLY REFEREED TO THE DESIGNER FORRESOLUTION.

15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND FINISHES AT INTERIOR AND EXTERIOR BUILDING.DAMAGED SURFACES AND FINISHES RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO COST TO THE OWNER BYTHE CONTRACTOR TO MATCH EXISTING ADJACENT.

16. THE CONTRACTORS SHALL BE RESPONSIBLY FOR COORDINATION WITH ALL TRADES. THE CONTRACTOR SHALL REFER TO ALL ASPECTS OF THEDRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO ARCHITECTURAL DRAWINGS, STRUCTURAL, MECHANICAL, ELECTRICAL,PLUMBING DRAWINGS AS WELL AS RELATED SPECIFICATIONS FOR COORDINATION ISSUES. COORDINATE ALL DIAGRAMMATIC DRAWINGS WITHALL TRADES TO ENSURE FIT AND COMPATIBLY.

17. PROVIDE DEMOLITION AS INDICATED, AND IF NOT INDICATED, AS REQUIRED TO COMPLETE NEW WORK INDICATED. SEE DEMOLITION NOTES.18. ALL NEW TENANT IMPROVEMENT WORK SHALL FULLY COMPLY WITH THE ACCESSIBLY PROVISIONS FOR NEW BUILDINGS PER CBC CHAPTER 11 B

JST. JOIST

VINYL COMPOSITION TILEVCT

L

L

L

YARDWROUGHT IRONWOODWITHOUTWITHWEIGHTWEATHER PROOFWAINSCOTWINDOWWATER CLOSETVERTICAL

VOLT AMPEREVERIFY IN FIELDVAPOR BARRIERURINALUNFINISHEDTYPICALTRANSFORMERTOILETTHROUGHTHICKTHREADEDTHRESHOLDTELEPHONETELEVISION OUTLETTUBE STEELTOP OF WALLTOP OF SLABTOP OF MASONRYTOP OF JOISTTOP OF FOOTING

TOP OF CURBTOP OF BEAMTOP OFTELEPHONE MOUNTING BOARDTHROUGH BOLTTONGUE AND GROOVESYSTEMSYMMETRICALSWITCHSUSPENDEDSTEELSTANDARDSOUND TRANSMISSION CLASSSQUARE INCHESSQUARE FEETSPEAKERSPECIFICATIONSSPACESIMILARSHEATHINGSHEET

SERVICE ENTRANCE SECTIONSECTIONSCHEDULESELF CLOSINGSTAINLESS STEELSKYLIGHTSHUT OFF VALVESMOKE DETECTORSOLID COREREMOVEROOMREVISIONRETURNREQUIREDREINFORCEDREFERENCEREFRIGERATORRIGHT OF WAYROUGH OPENINGROOF DRAIN OVERFLOWROOF DRAIN LEADERRADIUSQUANTITYQUARRY TILEPOWERPOLYVINYLCLORIDEPARTITIONPOUNDS PER SQUARE INCHPOUNDS PER SQUARE FOOTPREFABRICATED

PERFORATED

PORCELAINPLYWOODPLUMBINGPLASTICPLATEPLASTERPHASEPERPENDICULAR

POINT OF CONNECTIONPLASTIC LAMINATEPROPERTY LINEPRECAST CONCRETEOPPOSITE

OPENINGOVER HEADOUTSIDE AIR INTAKEOUTSIDE RADIUSORNAMENTAL IRONOVER HANGOUTSIDE DIAMETERON CENTERNOMINALNUMBERNAILERNOT FOR CONSTRUCTIONNON-CORROSIVE METALNOT TO SCALENOT IN CONTRACTMULLIONMETALMODULARMISCELLANEOUSMINIMUMMANUFACTURERMANUFACTURINGMEDIUMMECHANICALMAXIMUMMATERIALMASONRYMARBLEMASONRY OPENINGMALLEABLE IRONMANHOLEMACHINE BOLTLAMINATED VENEER LUMBERLIGHTINGLIGHTLINOLEUMLINEARLEADLAVATORYLATERALLAMINATELINEAR FEETLIGHT EMITTING DIODEKNOCK OUTKILN DRIEDKNOCK DOWNJOINT

JUNCTIONJUNCTION BOXINTERIORINSULATION"INCLUDE, INCLUSIVE"IMPREGNATEDINTERMEDIATE METALLIC CONDUITISOLATED GROUNDIDENTIFICATIONINSIDE FACEINSIDE DIAMETERINTERCOM OUTLETHYDRAULICHOT WATER

"HEATING, VENTILATING & AIR CONDITIONING"HEATERHORIZONTALHEIGHTHARDWAREHARDBOARDHANDICAPPEDHOLLOW METALHOLLOW COREHOSE BIBB

GYPSUM BOARDGYPSUMGALVANIZED RIGID TUBINGGATE VALVEGRADE MARKGLUE LAMINATED BEAMGLASSGROUND FAULT INTERRUPTERGROUND FAULT CIRCUIT INTERRUPTERGARAGEGALVANIZEDGAUGEGALVANIZED IRONFURNISHFOOTINGFIRE PROOFFLUORESCENTFLOORINGFLOORFINISHFIRE HOSE CABINETFOUNDATIONFIRE DEPARTMENT CONNECTIONFIRE ALARM CONTROL PANELFABRICATEFIBERGLASSFLOOR SINKFACE OF FIELD NAILINGFIRE EXTINGUISHERFLOOR DRAINFLOOR CLEAN OUTFAN COILFIRE ALARMEXTERIOREXISTINGEXHAUST

EXCAVATEELECTRIC DRINKING COOLEREVAPORATIVE COOLERESTIMATEEQUIPMENTEQUALELECTRICAL NON-METALLIC TUBINGELECTRICAL METALLIC TUBINGELECTRICAL METALLIC CONDUITELEVATOR"ELECTRIC, ELECTRICAL"ELEVATIONEACHEACH WAYEND NAILINGEXPANSION JOINTEXHAUST FANEXPANSION ANCHORDOORDOWNDEAD LOADDIMENSIONDIAGONALDIAMETERDEMOLITIONDOUBLEDISHWASHERDOWN SPOUTDECOMPOSED GRANITEDRINKING FOUNTAINPENNYCOPPERCONTRACTORCONTINUOUSCONSTRUCTIONCONCRETECOMBINATIONCOLUMNCENTEREDCONCRETE MASONRY UNITCLEARCLOSETCAULKINGCEILINGCENTERLINECIRCUIT BREAKERCHANNEL

CERAMICCEMENTCLOSED CIRCUIT TELEVISION

CAMBERCABINETCERAMIC TILECLEAN OUTCONTROL JOINTCAST IN PLACECONSTRUCTION DOCUMENTSCONCRETE ASBESTOS PIPEBRONZEBEARINGBRASSBEAMBLOCKINGBLOCKBUILDINGBOARDBACK OF CURBBUILT UPBOTTOM OF FOOTINGBOTTOM OFBOUNDARY NAILINGBENCH MARKANGLEAMERICAN WIRE GAUGEAVERAGEASPHALTANNEALEDALTERNATEALUMINUMAIR HANDLER UNITABOVE GRADEADDITION or ADDENDUM

ACOUSTICAL CEILING TILEACOUSTICASBESTOS-CEMENT BOARDABOVEACRYLONITRILE-BUTADIENE-STYRENEAGGREGATE BASE COURSEAIR CONDITIONINGABOVE FINISHED GRADEABOVE FINISHED FLOORANCHOR BOLTAMPERES

YD.W.I.WD.W/OW/WT.WPWCTWDWW/CVERT.

VAV.I.F.V.B.URUNF.TYP.TRANS.TLT.THRUTHK.THD.TH.TEL.T.V.T.S.T.O.W.T.O.S.T.O.M.

T.O.J.T.O.F.

T.O.C.T.O.B.T.O.T.M.B.T.B.T & GSYS.SYMSWSUSP.STL.STD.STCSQ. IN.SQ. FT.SPKR.SPECSSPA.SIM.SHT'G.SH

SESSECT.SCHED.SCS/SS/LS.O.V.S.D.S.C.RMV.RMREV.RET.REQ'D.REINF.REF.REFR.O.W. or R/WR.O.R.D.O.R.D.L.RQTY.Q.T.PWR.PVCPTN.PSIPSFPREFAB.

PERF.

PORC.PLYWD.PLUMB.PLAS.PL. or PPL.PH or ∅PERP. or

P.O.C.P.LAM.P.L. or PP.C.OPPO.

OPNG.OHOAIO.R.O.I.O.H.O.D.O.C.NOM.NO.NLR.NFCNCMN.T.S.N.I.C.MULMTL.MODMISC.MIN.MFR.MFG.MED.MECH.MAX.MAT'LMAS.MAR.M.O.M.I.M.H.M.B.LVLLTG.LT.LINO.LIN.LD.LAVLAT.LAML.FT.L.E.D.KOKDK-DJT.

JCTJ-BOXINT.INSUL.INCL.IMPGIMCIGIDI.F.I.D.I.C.HYD.HW

HVACHTRHOR.HGT.HDWHDBD.H/CH.M.H.C.H.B.

GYP. BD.GYP.GRCGMGMGLBGLGFIGFCIGAR.GALV.GA.G.I.FURN.FTG.FPFLUOR.FLG.FLFIN.FHCFDN.FDCFACPFAB.F/GF.S.F.O.F.N.F.E.F.D.F.C.O.F.C.F.A.EXT.EXIST. or EEXH.

EXCEWCEVAP.EST.EQUIP.EQ.ENTEMTEMCELEV.ELECT.ELEA.E.W.E.N.E.J.E.F.E.A.DRDN.DLDIM.DIAG.DIA. or ∅DEMODBL.D/WD.S.D.G.D.F.

dCUCONTR.CONT.CONST.CONC.COMB.COL.CNTRD.CMUCLR.CLO.CLKG.CLG.CL or CCKT. BKR.CH or

CERCEM.CCTV

CAM.CABC.T.C.O.C.J.C.I.P.C.D.C.A.P.BRZBRG.BRBM.BLKG.BLK.BLDGBD.B/CB.U.B.O.F.B.O.B.N.B.M.

AWGAVGASPH.ANLALT.AL. or ALUM.AHUAGADD.

ACTACOU.ACBABV.ABSABCA/CA.F.G.A.F.F.A.B.A

Abbreviations

Abbreviations (cont.)

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

27616 Newhall Ranch Rd. Ste. A10-15-25, Valencia, CA 91355Construction Documents

General Notes:

Scope of Work1.) New Partition Walls2.) New Flooring3.) New Doors4.) New Windows5.) New Electrical Outlets6.) New T-bar Ceiling Gird

7.) New Lighting Fixtures8.) New Plumbing Fixtures9.) Fire Alarm Modification10.)Fire SprinklerModification

S

N

W E

SITE27616 Newhall Ranch Rd.Ste. A10-15-25,Valencia, CA 91355

ArchitrecturalT-0.0 Title SheetT-0.1 NotesA-0.1 Site PlanA-0.2 Accessibility RequirementA-0.3 Accessibility RequirementA-0.4 Site Plan and ADA Access RouteA-0.5 ADA Restroom Standards & DetailsA-1.0 As-Built/Demo Floor PlanA-1.1 Proposed Floor PlanA-1.20 Demo'd Reflected Ceiling PlanA-1.21 Suspended ceiling tile detailA-1.2 Reflected Ceiling PlanA-1.3 Finished Floor Plan

ElectricalE-0.1 Electrical Symbol List, Abbreviations and Sheet IndexE-0.2 General Notes, Demolition Notes, Fire Alarm Notes and Code AnalysisE-1.1 Demolition Lighting PlanE-1.2 Demolition Roof Electrical PlanE-2.1 New Lighting PlanE-2.2 New Construction Power PlanE-2.3 New Construction Fire Plan

Electrical (cont.)E-3.1 Single line Diagram Panel Schedules and Load CalculationsE-3.2 Title 24 Lighting FormsE-3.3 Title 24 Lighting FormsE-3.4 Title 24 Lighting FormsE-3.5 Title 24 Lighting FormsE-4.1 Electrical DetailsMechanicalM-0.1 Mechanical Symbol List, Abbreviation and Sheet IndexM-1.1 Demolition Mechanical PlanM-2.1 New Construction Mechanical PlanM-4.1 Mechanical Details

PlumbingP-0.1 Plumbing Symbol List, Abbreviation, and Sheet IndexP-0.2 Plumbing Symbol List, Abbreviation, and Sheet IndexP-0.3 Title 24P-1.1 Demolition Plumbing PlanP-2.1 New Construction Plumbing Plan

1

SMALL GROUP INSTRUCTIONSGI

8/1/

16Re

visi

on1

1. Sprinklered2. Exiting to remain unchanged.3. Restrooms are "in compliance".

NOTES

1

AMERICANS WITH DISABILITY ACTADA

CUBIC FEET PER MINUTECFM

CALIFORNIA BUILDING CODECBC

GYPSUM WALL BOARDGWB

Deferred SubmittalsFire Sprinkler systemFire Alarm system

1

PERMIT #:BLD16-01504

2

10/5

/16

Revi

sion

2

Applicable Codes2013 California Building Code2013 California Electrical Code2013 California Mechanical Code2013 California Plumbing Code2013 California Fire Code2013 California Energy Code

2

Class:A (Interior Wall & Ceiling Finish): Flame spread- 0-25 Smoke Developed- 0-450

3

10/x

x/16

Revi

sion

3

3

3

11/3

/16

Revi

sion

4

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7N

otes

Cons

truc

tion

Docu

men

ts

T-0.1

5/23

/16

CHK

-/-

Regi

onal

Dire

ctor

5/23

/16

-/-

-/-

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

8/1/

16Re

visi

on1

PERMIT #:BLD16-01504

10/5

/16

Revi

sion

2

10/x

x/16

Revi

sion

3

3

11/3

/16

Revi

sion

4

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7A0

.2 A

cces

sibi

lity

Requ

irem

ent

A-0.2

5/23

/16

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Cons

truc

tion

Docu

men

ts

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

5/23

/16

PERMIT #:BLD16-01504

10/5

/16

Revi

sion

2

8/1/

16Re

visi

on1

11/3

/16

Revi

sion

4

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7A0

.3 A

cces

sibi

lity

Requ

irem

ent

A-0.3

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Cons

truc

tion

Docu

men

ts

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

5/23

/16

5/23

/16

PERMIT #:BLD16-01504

10/5

/16

Revi

sion

2

8/1/

16Re

visi

on1

11/3

/16

Revi

sion

4

(e)S

oC

al P

hysic

al

Therapy

and A

cupunctu

re

(O

ccupancy g

roup:B

)

(e)D

ental C

are

(O

ccupancy g

roup:B

)

D

ic

k

a

s

o

n

D

r

.

N

e

w

h

a

l

l

R

a

n

c

h

R

d

.

7-Eleven

Carl's

Jr.

Retail/Office

/Commercial

Retail/Office

/Commercial

Retail/Office/Commercail

SoCal Physical Therapy

and Acupuncture

(not in scope of work)

Dental Group

(not in scope of work)

7

1

7

1

9

1

7

1

5

1

12

1

12

1

12

1

3

1

1

6

1

12

1

1

4

1

11

6

1

10

1

2

1

1

1

2

1

1

5

1

2

3

1

10

4

1

4

1

7

1

6

1

5

1

7

1

6

1

6

1

4

1

5

1

4

1

3

1

5

1

3

1

7

1

12

1

6

5

T

r

a

s

h

E

n

c

l

o

s

u

r

e

T

r

a

s

h

E

n

c

l

o

s

u

r

e

T

r

a

s

h

E

n

c

l

o

s

u

r

e

T

r

a

s

h

E

n

c

l

o

s

u

r

e

1

5

8

1

(e)OCCUPANCY GROUP: B

(e)OCCUPANCY GROUP: B

FIRE HYDRANT

FIRE HYDRANTS

FIRE HYDRANT

FIRE HYDRANT

1

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7Si

te P

lan

and

ADA

Acce

ss R

oute

A-0.4

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Cons

truc

tion

Docu

men

ts

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

5/23

/16

5/23

/16

NTS

SITE PLAN (FOR REFERENCE ONLY)

1

NTS

PARTIAL SITE PLAN AND ACCESSIBLE PATH OF TRAVEL

2

North

North

2

8/1/

16Re

visi

on1

1

1

PERMIT #:BLD16-01504

10/5

/16

Revi

sion

2

11/3

/16

Revi

sion

4

K-2015-8PINOIRLAVATORYVITREOUS CHINA

18"

18"18"

3'

42" MIN.

8'-0"

18"

18"

7'-8"

54"

12"

MAX.

48" MIN. CLR.

6

0

"

M

I

N

.

1

2

"

M

A

X

.

60"

MIN

.

K-2015-8PINOIRLAVATORYVITREOUS CHINA

18"

6

0

"

M

I

N

.

42

" M

IN

.

8'-0

"

54

"

12

"

M

AX

.

1

2

"

M

A

X

.

10'-0"

60"

MIN.

18"

K-2015-8PINOIRLAVATORYVITREOUS CHINA

18

"

42" MIN.

7'-6"

54"

12"

MAX.

6

0

"

M

I

N

.

18

"

60

"

MIN

.

7'-6

"

K-2015-8PINOIRLAVATORYVITREOUS CHINA

18

"1

8"

42" MIN.

7'-6"

54"

12"

MAX.

60

"

MIN

.

6

0

"

M

I

N

.

8'-4

"

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7

A-0.5

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

ENLARGED RESTROOM - 111

1

STANDARD ACCESSIBLE RESTROOM2

HI-LO DRINKING FOUNTAIN

3

STANDARD ACCESSIBLE RESTROOM45

STANDARD ACCESSIBLE RESTROOM ACCESSORIES (HGTS)

7

STANDARD ACCESSIBLE RESTROOM SIGNAGE6

AD

A R

estroom

S

tandards &

D

etails

Cons

truc

tion

Docu

men

ts

5/23

/16

5/23

/16

1

UNISEX RESTROOM

UNISEX

UNISEX

WOMEN'S RESTROOM

MEN'S RESTROOM

LC

LC

LC

LC

NOTES: LETTERS AND NUMBERS ON SIGNS SHALL BE

RAISED, CONTRASTING IN COLOR, AND HAVE A

WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1

AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN

1:5 AND 1:10, AND RAISED

1

32

" MIN. AND BE

ACCOMPANIED BY BRAILLE RAISED LETTERING.

WHERE PERMANENT SIGNAGE IS PROVIDED FOR

ROOMS AND SPACES, SIGNAGE AS DESCRIBED

ABOVE SHALL BE PROVIDED ON THE STRIKE SIDE

OF THE DOOR.

MIN. 6" x 6" x

1

4

" FIELD

WITH SYMBOLS.

5

8

" HIGH MIN. TYPE

RAISED

1

32

" HELVETICA

MEDIUM UPPERCASE

LETTERS.

MIN. 2" x 6" x

1

4

" FIELD

WITH TEXT AND GRADE

2 BRAILLE (PER CBC 1011.4)

BELOW.

TEXT.

TRIANGLE

1

4

" THICK SUPERIMPOSED

ON 12" DIA. CIRCLE

MIN. 6" x 6" x

1

4

"

FIELD WITH SYMBOLS.

5

8

" MIN. (2"MAX) HIGH

1

32

"

RAISED, UPPER CASE, SANS

SERIF TYPESTYLE

GRADE 2 BRAILLE "EXIT"

DOOR SIGN AT TOILET ROOMS

DOOR SIGN AT ENTRANCE

(NOTE" SIGN TO MEET ALL LOCAL, ADA,

CA TITLE 24, & CBC 2013 CODE REQUIREMENTS)

6"

6"

3" MIN.

4"

60" A

.F

.F

.

6"

60"

60" A

.F

.F

.

60" A

.F

.F

.

12" D

IA

. 1

2

"

T

Y

P

.

60" M

AX

.

TO

B

AS

ELIN

E

OF

H

IG

HE

ST

48" M

IN

.

TO

B

AS

ELIN

E

OF

B

RA

ILLE

EXIT

(PER CBC 1011.4)

CH

AR

AC

TE

R

60" M

AX

.

TO

B

AS

ELIN

E

OF

H

IG

HE

ST

CH

AR

AC

TE

R

1

1

1

8/1/

16Re

visi

on1

1

8

TYPICAL UPPER CABINET

ACCESSIBLE SINK CABINET

NOTE:CONTRACTOR SHALL BE RESPONSIBLE FOR

ALL ACCESSORIES IN ALL RESTROOMS

1

AB

C D

LC

7"-9"

STANDARD ACCESSIBLE TOILET STALL

(SIDE ELEVATION)

GRAB BARS:

GRAB BARS TO BE 1 1/4-1 1/2" WITH 1 1/2" CLEARANCE BETWEEN

THE GRAB BAR AND WALL. BARS ARE SMOOTH WITH A MIN.

RADIUS OF 1/8". MIN. STRUCTURAL STRENGTH OF GRAB BARS TO

BE 250 LBS POINT LOAD GRAB BARS DO NOT ROTATE WITHIN

THEIR FITTINGS.

STANDARD ACCESSIBLE

TOILET STALL

(FRONT ELEVATION)

STANDARD ACCESSIBLE

RESTROOM (PLAN)

STANDARD ACCESSIBLE

SINK (SECTION)

52" MIN.

12" MAX 42" MIN.

24" MIN.

36" MAX.

48" MIN.

33

"

36

" IF

T

AN

K

40

" M

IN

.

19

" M

IN

.

OB

ST

RU

CT

S

MAX.

I.P.

33

"

36

" IF

T

AN

K

OB

ST

RU

CT

S

60" MIN.

42" MIN.

32" MIN.17"-18"

17

"-1

9"

12

"

36" MIN.

12"

6" MAX.

24"

18" MIN.

34

" M

AX

.

D

-

DRAIN AND HOT WATER PIPING IS

INSULATED OR CONFIGURED TO PREVENT

CONTACT. THERE ARE TO BE NO

SHARP OR ABRASIVE ELEMENTS UNDER

LAVATORY.

STD. ACCESSIBLE LAVATORY ELEVATION

30"x48"x27"

74

" M

IN

.

40

" M

AX

. T

O M

IR

RO

R

34

" M

AX

.

29

" M

IN

.

27

" M

IN

.

9" M

IN

.

6" MAX.

17" MIN. DEPTH

(TOE CLEARANCE)

8" MIN.(KNEE CLEARANCE)

STD. ACCESSIBLE LAVATORY ELEVATION

MIRROR

17" MIN.

19" MAX

1

8

"

(

M

I

N

.

)

1

8

"

(

M

I

N

.

)

36" M

AX

.

TO

B

UB

BLE

R

27" M

IN

.

CLE

AR

42" (M

AX

)

TO

B

UB

BLE

R

6" MAX 36" MIN

42" MIN17"-18"60" MIN. CLR

56" M

IN. A

T W

ALL

MTD

M.C

.

59" M

IN. A

T FL

R M

TD M

.C.

60" M

IN

34" M

IN

36" M

IN

18" M

IN.

2'-0

"

32" M

IN.

60" X 60" CLR.

32"MIN.

12"M

AX.

42" M

IN.

7"-9

" MAX

TO

TP

24" MIN. 36" MIN.

60" M

IN.

42" M

IN.

7"-9

" MAX

TO

TOP

34" M

IN.

44" M

IN.

42" MIN.

12" M

AX.

35" MIN

60" MIN.

6" MAX36" MIN.17"-18"

B SINGLE ACCOMMODATIONS TOILETS

A MULTIPLE ACCOMMODATIONS TOILETS

58"

60" MIN42" MIN 18"

30" MIN

48" M

IN

60" M

IN

60" M

IN

32" MIN

12" MAX

18"18"60" MIN CBC 1115B.4.1.2.1

12" M

AX.

56"

42" M

IN.

48" M

IN C

LEAR

FLUSH

ACTIVATOR

ON WIDE

SIDE

PERMIT #:BLD16-01504

10/0

5/16

Revi

sion

2

PLUMBING FIXTURE CALCULATIONS

14

11

ENLARGED RESTROOM - 109

ENLARGED RESTROOM - 102

12

3

10/x

x/16

Revi

sion

3

3

3

3

3

16

ENLARGED RESTROOM - 106

WATER

CLOSETS

MALE

1/50

FEMALE

1/30

URINALS

MALE

1/100

REQUIRED

LAVATORIES

MALE

1/40

FEMALE

1/40

1.36 2.26 0.68 1.7 1.7

PLUMBING FIXTURE CALCULATIONS - PER 2013 CALIFORNIA PLUMBING CODE - TABLE 422.1

TOTAL OCCUPANT LOAD : 136 (MEN = 68, WOMEN = 68)

*UNISEX TOILETS ARE PROVIDED

PROVIDED 4 4 0* 4 4

11/3

/16

Revi

sion

4

10

8

(e

)M

AIN

U

TIL

IT

Y R

OO

M

K-2015-8PINOIRLAVATORYVITREOUS CHINA

K-2015-8PINOIRLAVATORYVITREOUS CHINA

38 squ.ft.

(e)IT Closet

68 squ.ft.

106

(e)Unisex

Toilet

508 squ.ft.

(e)KIT/STOR

401 squ.ft./20 net = 20.05 occ. load

115

(e)SGI Room

150 squ.ft.

Office

646 squ.ft./20 net = 32.3 occ. load

113

(e)TRAINING ROOM

K-2015-8PINOIRLAVATORYVITREOUS CHINA

K-2015-8PINOIR

LAVATORYVITREOUS CHINA

68 squ.ft.

109

(e)Unisex

Toilet

61 squ.ft.

111

(e)Unisex

Toilet

136 squ.ft.

(e)Toilet

111 squ.ft./100 net = 1.11 occ. load

112

(e)Office

278 squ.ft.

SGI Room

2,186 squ.ft.

(e)BUSINESS AREA

1,258 squ.ft.

(e)BUSINESS AREA

(e)CLOSET

56 squ.ft.

102

(e)Unisex

Toilet

26 squ.ft.

103

(e)IT Closet

(

e

)

S

o

C

a

l

P

h

y

s

i

c

a

l

T

h

e

r

a

p

y

a

n

d

A

c

u

p

u

n

c

t

u

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

(

e

)

D

e

n

t

a

l

C

a

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7As

-Bui

lt/De

mo

Floo

r Pla

n

A-1.0

CHK

Regi

onal

Dire

ctor

-/-

Scale: 3/16"=1'-0"

As-Built/Demo Floor Plan(~6,578 squ.ft.)

1

North

-/-

-/-

Cons

truc

tion

Docu

men

ts

EXISTING WALL

NEW METAL STUD WALL w/ GYP. BD.

WALL LEGEND

SYMBOLS

FLUSH WOOD DOOR (Refer to Door Schedule)

SINGLE-GLASS DOOR (Refer to Door Schedule)

HI-LO DRINKING FOUNDTAIN

WINDOWS - (Refer to Window Schedule)

PATH OF TRAVEL

DEMOLITIONED WALL

SECTION REFERENCE ON SHEET

SHEET WHERE SECTION IS DRAWN

SECTION SYMBOL

ELEVATION REFERENCE ON SHEET

SHEET WHERE ELEVATION IS DRAWN

ELEVATION SYMBOL

101

ROOM NAME

ROOM NAME

ROOM NUMBER

ROOM (NAME/NUMBER) SYMBOL

ELEV: 10'-0"

(V. I. F.)

HEIGHT

NOTIFACATION

ELEVATION SYMBOL

DETAIL REFERENCE ON SHEET

SHEET WHERE DETAIL IS DRAWN

DETAIL SYMBOL

D1

DOOR SYMBOL

W1

WINDOW SYMBOL

DOUBLE-GLASS DOOR (Refer to Door Schedule)

1-HR SEPARATION WALL

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

FLOOR MOUNTED TOILET

LAVATORY SINK

URINAL

K-2015-8PINOIRLAVATORYVITREOUS CHINA

5/23

/16

5/23

/16

EXISTING WALL

(OCCUPANCY SEPARATION 1-HR. FIRE)

1

1

1 1

EXISTING WALL

(OCCUPANCY SEPARATION 1-HR. FIRE)

1

8/1/

16Re

visi

on1

DIRECTIONAL EXIT SIGN (CBC 1011)

1

DEMOLITION FLOORING TO CONCRETE BASE

NOTES:

1.) PRIOR DEMOLITION, CONTRACTOR SHALL BE RESPONSIBLE

FOR VERIFYING ALL WALLS TO BE DEMOLISHED.

2.) AT LEAST 50% OF THE CONSTRUCTION DEBRIS SHALL BE RECYCLED.

SEE AGENCY CLEARANCE LIST FOR CONTACT INFORMATION FOR

SANTA CLARITA ENVIRONMENTAL SERVICES FOR ADDITIONAL GUIDANCE....

3.) SEE STRUCTURAL ENGINEER'S LETTER VERIFYING THIS IS NOT LOAD BEARING WALL.

PERMIT #:BLD16-01504

2

2

10/0

5/16

Revi

sion

2

3

1 3

SEE NOTE 3

10/x

x/16

Revi

sion

3

11/3

/16

Revi

sion

4

10

8

(e

)M

AIN

U

TIL

IT

Y R

OO

M

K-2015-8PINOIRLAVATORYVITREOUS CHINA

K-2015-8PINOIRLAVATORYVITREOUS CHINA

68 squ.ft.

106

(e)Unisex

Toilet

401 squ.ft./20 net = 20.05 occ. load

115

(e)SGI Room

646 squ.ft./20 net = 32.3 occ. load

113

(e)TRAINING ROOM

15'

188 squ.ft./15 net = 12 occ. load

101

CONFFERENCE

336 squ.ft./300 net = 1.12 occ. load

105

STORAGE

360 squ.ft./20 net = 18 occ. load

110

SGI ROOM #2

K-2015-8PINOIRLAVATORYVITREOUS CHINA

K-2015-8PINOIRLAVATORYVITREOUS CHINA

68 squ.ft.

109

(e)Unisex

Toilet

61 squ.ft.

111

(e)Unisex

Toilet

111 squ.ft./100 net = 1.11 occ. load

112

(e)Office

411 squ.ft./20 net = 20.55 occ. load

114

SGI ROOM #1

120 squ.ft./100 net = 1.2 occ. load

104

CONSUL

12

'

2,840 squ.ft./100 net = 28.4 occ. load

100

BUSINESS AREA

Align

Align

Align

Align

Align

Align

Align

10'6'

Align Align

Align

(TYP.)

56 squ.ft.

102

(e)Unisex

Toilet

26 squ.ft.

103

(e)IT Closet

3'

(

e

)

S

o

C

a

l

P

h

y

s

i

c

a

l

T

h

e

r

a

p

y

a

n

d

A

c

u

p

u

n

c

t

u

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

(

e

)

D

e

n

t

a

l

C

a

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

175 squ.ft./200 net = 0.875 occ. load

107

KITCHENETTE

RECEPTION

36"HGT

PONY WALL

18"18"

Align

6'

3'

8'-0"

6'

3'

3'

7'

ADA EXIT SIGN

PER

ADA EXIT

SIGN PER

ADA EXIT

SIGN PER

Fire chalking all existing penetrations

and tape all gypsum board joints

Fire chalk all existing penetrations

and tape all gypsum board joints

7

8

7

8

WOOD SCREWS

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7Pr

opos

ed F

loor

Pla

n

A-1.1

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Scale: 3/16"=1'-0"

Proposed Floor Plan

1

EXISTING WALL

NEW METAL STUD WALL w/ GYP. BD.

WALL LEGEND

SYMBOLS

FLUSH WOOD DOOR (Refer to Door Schedule)

SINGLE-GLASS DOOR (Refer to Door Schedule)

HI-LO DRINKING FOUNDTAIN

WINDOWS - (Refer to Window Schedule)

PATH OF TRAVEL

DEMOLITIONED WALL

SECTION REFERENCE ON SHEET

SHEET WHERE SECTION IS DRAWN

SECTION SYMBOL

ELEVATION REFERENCE ON SHEET

SHEET WHERE ELEVATION IS DRAWN

ELEVATION SYMBOL

101

ROOM NAME

ROOM NAME

ROOM NUMBER

ROOM (NAME/NUMBER) SYMBOL

ELEV: 10'-0"

(V. I. F.)

HEIGHT

NOTIFACATION

ELEVATION SYMBOL

DETAIL REFERENCE ON SHEET

SHEET WHERE DETAIL IS DRAWN

DETAIL SYMBOL

D1DOOR SYMBOL

W1

WINDOW SYMBOL

2

NON-RATED METAL STUD PARTITION

3

DOUBLE-GLASS DOOR (Refer to Door Schedule)

4

North

Cons

truc

tion

Docu

men

ts

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355(See Schedule A-1.3)

(See Schedule A-1.3)

FLOOR MOUNTED TOILET

LAVATORY SINK

URINAL

K-2015-8PINOIRLAVATORYVITREOUS CHINA

5/23

/16

5/23

/16

1

1

1

1

1

1

1

1

1

1

1

OCCUPANCY LOAD SCHEDULENAME ROOM # ACTUAL

AREAFUNCTION OF

SPACEOCCUPANCY

LOAD FACTOROCCUPANT

LOAD

BUSINESSAREA

100 2840 squ. ft. Business Area 100 SF 28.4

CONFERENCE 101 188 squ.ft. Business Area 15 SF 12

CONSUL 104 120 squ. ft. Business Areas 100 SF 1.2

STORAGE 105 336 squ. ft. Storage Areas 300 SF 1.12

KITCHENETTE 107 175 squ. ft. Teacher Lounge 200 SF 0.875

SGI ROOM #2 110 360 squ. ft. Small GroupInstruction

20 SF 18

(e)OFFICE 112 111 squ. ft. Business Areas 100 SF 1.11

(e)TRAININGROOM

113 646 squ. ft. Classroom 20SF 32.3

SGI ROOM #1 114 411 squ. ft. Small GroupInstruction

20SF 20.55

(e)SGI ROOM 115 401 squ. ft. Small GroupInstruction

20SF 20.05

TOTAL 136

DIRECTIONAL EXIT SIGN (CBC 1011)

8/1/

16Re

visi

on1

NOTE:

Patch and match 1-HR. walls after plumbing work as required,

to maintain prior appearance.

Provide fire extinguishers @ every 75' apart.

TYP. METAL STUD BACKING

5

6

TYP. FRAMING @ OPENING

7

TYP. FRAMING DETAIL

8

TYP. BRACING DETAIL

1

1

PERMIT #:BLD16-01504

1-HR SEPARATION WALL

GENERAL NOTES1. Toilet room floors shall have a smooth, hard,

nonabsorbent surface that extends upward onto thewalls at least 4 inches.

2. Walls within 2 feet of urinals and water closets shallhave a smooth hard, nonabsorbent surface to aheight of 4 feet above the floor. except for structuralelements, the materials used in such walls shall be ofa type that is not adversely affected by moisture.

10/0

5/16

Revi

sion

2

2

EXISTING WALL (UL U419)

(OCCUPANCY SEPARATION 1-HR. FIRE)

SEE DWG 4/-

EXISTING WALL (UL U419)

(OCCUPANCY SEPARATION 1-HR. FIRE)

SEE DWG 4/-

1 31 3

3

3

3

3

9

TYP. BLOCKING DETAIL

10

Penetration at fire rated wall

2

10/x

x/16

Revi

sion

3

ONE HR RATED SEPARATED WALL

NON-RATED METAL STUD PARTITION

NOTE:

FIRE CAULKING AND SEALANT ARE REQUIRED WHERE PIPE/AND OR CONDUIT

PENETRATION OCCUR. SEE DWG 10/-.

UL Design No. 1479

11/3

/16

Revi

sion

4

101

CONFFERENCE

8'-0" (Typ.Clg.Hgt)

114

SGI ROOM #1

107

KITCHEN

110

SGI ROOM #2

108

Main Utility Room

8'-0" (Typ.Clg.Hgt)

105

STORAGE

100

BUSINESS AREA

111

(e)Unisex

Toilet

112

(e) Office

113

(e) Training Room

115

(e) SGI Room

109

(e)Unisex

Toilet

104

CONSUL

103

IT Closet

102

(e) Unisex

Toilet

106

(e)Unisex

Toilet

(

e

)

S

o

C

a

l

P

h

y

s

i

c

a

l

T

h

e

r

a

p

y

a

n

d

A

c

u

p

u

n

c

t

u

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

(

e

)

D

e

n

t

a

l

C

a

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7Re

flect

ed C

eilin

g Pl

anCo

nstr

uctio

n Do

cum

ents

A-1.2

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Scale: 1/8"=1'-0"

Reflected Ceiling Plan

1

North

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

(Refer to Mech. and Elect construction documents.)

5/23

/16

5/23

/16

2X4 Heavy Duty Acoustical Gird and Tile System

CEILING LEGEND

2x4 Lighting(refer to Electrical Plan E-2.1)

1

8/1/

16Re

visi

on1

NOTES:

1. All ceiling heights to be 8'-0" A.F.F. TYP.

2. Match and patch new T-bar ceiling to existing T-bar ceiling.

3. T-bar ceiling details and methods of connection, refer to

(1/A-1.2)

4. Contractor to provide ties as needed

5. Add new lighting fixtures per approximate location.

6. Refer to Electrical Plan (E-2.1)

7. T-Bar Ceiling ICC# ESR-1308

1

PERMIT #:BLD16-01504

2

10/0

5/16

Revi

sion

2

10/x

x/16

Revi

sion

3

See also Electrical Plan E-2.1

11/3

/16

Revi

sion

4

101

CONFFERENCE

8'-0" (Typ.Clg.Hgt)

114

SGI ROOM #1

107

KITCHEN

110

SGI ROOM #2

108

Main Utility Room

8'-0" (Typ.Clg.Hgt)

105

STORAGE

100

BUSINESS AREA

111

(e)Unisex

Toilet

112

(e) Office

113

(e) Training Room

115

(e) SGI Room

109

(e)Unisex

Toilet

104

CONSUL

103

IT Closet

102

(e) Unisex

Toilet

106

(e)Unisex

Toilet

(

e

)

S

o

C

a

l

P

h

y

s

i

c

a

l

T

h

e

r

a

p

y

a

n

d

A

c

u

p

u

n

c

t

u

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

(

e

)

D

e

n

t

a

l

C

a

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

TYPE C

TYPE A

2"

5

8

1

15

16

"

1

9

16

"or1

15

16

"

VARIES

Notes:

Material: 12 to 16 gauge steel(typ.)

"

7

16

" Return Typical

Face

Jamb

Depth

VARIES

Throat

7/16" Return Typical for 5-3/4" Jamb Depth

TYPE B

TYPE D

3/8" FIXED TEMPERED GLASS

2 1/2"

1/4"

WINDOW HEAD

3/8" FIXED TEMPERED GLASS

SASH

3 5/8" METAL STUDS

JAMB

3/8" FIXED TEMPERED GLASS

SASH

3 5/8" METAL STUDS

5/8" GWB

HEADER

3/8" FIXED TEMPERED GLASS

SASH

3 5/8" METAL STUDS

5/8" GWB

TYPE BTYPE A

TYPE D

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7Fi

nish

ed F

loor

Pla

n&Sc

hedu

les

Cons

truc

tion

Docu

men

ts

A-1.3

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

THRESHOLD DETAILS

2

Scale: 1/8"=1'-0"

Finished Floor Plan

1

North

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

DOOR & FRAME SCHEDULEDOOR FRAME HARDWARE FIRE RATING &

ETC.NO. SIZE TYPE MAT. CORE FINISH GLASS TYPE MAT. FINISH

(e)100.1 72"x80"x1-3/4" A (e) (e) (e) (e) (e) (e) (e) LS, CL, PH (VIF) -

(e) 100.2 72"x80"x1-3/4" A (e) (e) (e) (e) (e) (e) (e) LS, CL, PH (VIF) -

(e) 100.3 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) LS, CL (VIF) -

(e) 100.4 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) LS, CL, PH (VIF) -

101.1 36"x80"x1-3/4" B HM PC PRE GL A HM PRE LS,CL, SP -

(e) 102.1 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) (e) -

103.1 36"x80"x1-3/4" D W SC PRE - A HM PRE LS, CL -

104.1 36"x80"x1-3/4" B HM PC PRE GL A HM PRE LS, CL,SP -

105.1 36"x80"x1-3/4" C HM PC PRE GL A HM PRE LS,CL,SP -

(e) 106.1 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) (e) -

(e) 107.1 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) LS, CL, PH (VIF) -

(e) 108.1 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) PH, CL -

(e) 108.2 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) LS -

109.1 36"x80"x1-3/4" C W SC ST - A HM PRE LS,CL -

110.1 36"x80"x1-3/4" B HM PC PRE GL A HM PRE LS,CL, SP -

(e) 111.1 36"x80"x1-3/4" C (e) (e) (e) - (e) (e) (e) (e) -

(e) 112.1 36"x80"x1-3/4" B (e) (e) (e) GL (e) (e) (e) LS -

(e) 113.1 36"x80"x1-3/4" B (e) (e) (e) GL (e) (e) (e) LS -

114.1 36"x80"x1-3/4" B HM PC PRE GL A HM PRE LS,CL, SP -

(e)115.1 36"x80"x1-3/4" B (e) (e) (e) (e) (e) (e) (e) LS -

(e) 115.2 36"x80"x1-3/4" B (e) (e) (e) (e) (e) (e) (e) LS, CL, PH (VIF) -

WINDOW SCHEDULEROOM

NUMBERSIZE TYPE GLASS FRAME - - -

NOTES - -

104-1 6'-0" x 4'-0" W1 FX AL - - - - - -

110-1 6'-0" x 4'-0" W1 FX AL - - - - - -

101-1 4'-0" x 4'-0" W2 FX AL - - - - - -

AL ALUMINUM FX 3/8" FIXED TEMPERED GLASS PB PANIC BAR TH ALUMINUM THRESHOLD

BB BALL BEARING BOLTS HM HOLLOW METAL PRE PRE-FINISHED W WOOD

C CHAIN IN INSULATED PT PAINT WS WEATHERSTRIPPING

CL CLOSER LPRS CAL ROYAL SL-20 LEVER PRIVACY SET SC SOLID CORE E EXISTING DOOR TO REMAIN

DB DEAD BOLT LS CAL ROYAL SL-00 LOCK SET ST STAIN PC POLYSTYRENE SLAB CORE

GL 3/8" TEMPERED GLASS NRP NON REMOVABLE PIN SP STOP PH PANIC HARDWARE

ROOM FLOOR WALL CEILING NOTES

NO. ROOM NAME BASE FINISH

NORTH SOUTH WEST EAST

MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN.

100 BUSINESS AREA RB CPT - - - - - - - - ACT Thresholds similar or equal to 2/A-1.3

101 CONFERENCE ROOM RB CPT DW PT1 - PT1 - PT2 DW PT2ACT Thresholds similar or equal to 2/A-1.3

102 (e) Toilet VB VS - PT1 - PT1 - PT1 - PT1

103 (e)IT Closet VB VS - PT1 - PT1 - PT1 - PT1

104 CONSUL RB CPT - PT2 DW PT2 DW PT3 - PT3ACT Thresholds similar or equal to 2/A-1.3

105 STORAGE VB VS - PT1 DW PT1 - PT1 DW PT1ACT Thresholds similar or equal to 2/A-1.3

106 (e) Toilet VB VS - PT2 - PT2 - PT2 - PT2

107 KITCHENETTE RB VCT 1&2 - PT2 DW PT2 - PT1 - PT1ACT Thresholds similar or equal to 2/A-1.3

108 (e) Main Utility Room VB VS - - - - - - - -

109 (e) Toilet VB VS - PT2 DW PT2 - PT2 - PT2

110 SGI ROOM #2 RB VCT 2&3 - PT1 DW PT1 - PT2 DW PT2ACT Thresholds similar or equal to 2/A-1.3

111 (e) Toilet VBVS - PT1 - PT1 - PT1 - PT1

112 (e) Office RBCPT - PT3 - PT3 - PT3 - PT3

113 (e) Training Room VBVS - PT2 - PT2 - PT2 - PT?

114 SGI ROOM #1 RB VCT 2&3 DW PT1 - PT1 DW PT2 - PT2 ACT Thresholds similar or equal to 2/A-1.3

115 (e) SGI Room RB VCT 2&3 - PT1 - PT1 - PT2 - PT2

1. REFER TO THE PLANS AND SPECIFICATIONS FOR ADDITIONAL DOORINFORMATION.

2. VERIFY THAT ALL DOORS AND DOOR HARDWARE MEET THEREQUIREMENTS OF THE CALIFORNIA ADMINISTRATION CODE(TITLE 24),AND ALL OTHER GOVERNING CODES AND STANDARDS. NOTIFY THEARCHITECT IMMEDIATELY IN THE CASE OF DISCREPANCY.

3. EXIT DOORS:A. ALL EXIT DOORS SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE

OF A KEY OR ANY SPECIAL KNOWLEDGE.B. ALL DOOR SWINGS SERVING AN OCCUPANT LOAD OF 50 OR GREATER

SHALL SWING IN THE DIRECTION OF EXIT.C. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL

NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY

ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THEFOLLOWING AREAS: AISLES AND UNENCLOSED EGRESS STAIRWAYS INROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS.

CORRIDORS, INTERIOR EXIT STAIRWAYS AND RAMPS AND EXITPASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.

INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION1027.1, IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.

THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR ADURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OFSTORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR.

4. MOUNT ALL HARDWARE PER LATEST EDITION OF THE GOVERNING CODES.5. ALL GLAZING IN DOORS OR WITHIN FORTY (40') INCHES OF THE LOCKING

DEVICE SHALL BE FULLY TEMPERED.6. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH

ARE IN THE PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLEEFFORT BY LEVEL TYPE HARDWARE, BY PANIC BARS, PUSH-PULLACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGEWITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWAREPER CALIFORNIA ADMINISTRATIVE CODE, TITLE 24, SECTION 2-3304(c)4,CHAPTER 33.

7. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THEFOLLOWING PER THE REQUIREMENTS OF CALIFORNIA ADMINISTRATIVECODE, TITLE 24, SECTION 2-3304(m)2.

A. INTERIOR DOORS - 5 POUNDSB. EXTERIOR DOORS - 5 POUNDSC. FIRE DOORS - 5 POUNDS

General Notes

5/23

/16

5/23

/16

Carpet Separator

Saddle

VCT to Carpet Separator

W1

114-1

W1

W1

110-1

109-1

104-1

101-1

105-1

(e)

(e)

(e)

(e)

(e)

107-1108-1

(e)

(e)

(e)

(e)

(e)

(e)

(e)

(e)

(e)

1

1

1

1

1

1

1

1

1

1

11

1

1

1

1

1

2

1

1

1

1

1

8/1/

16Re

visi

on1

PERMIT #:BLD16-01504

2

(e)(e)

100-4

100-3

(e)

102-1

100-2

100-1

1

115-1

115-2

113-1

(e)

113-2

103-1

108-2

106-1

111-1

112-1

10/5

/16

Revi

sion

2

2

2

2

2

2

1

2

2

11/3

/16

Revi

sion

4

108

(e)M

AIN

U

TILIT

Y R

OO

M

68 squ.ft.

106

(e)Unisex

Toilet

401 squ.ft./20 net = 20.05 occ. load

115

(e)SGI Room

646 squ.ft./20 net = 32.3 occ. load

113

(e)TRAINING ROOM

68 squ.ft.

109

(e)Unisex

Toilet

61 squ.ft.

111

(e)Unisex

Toilet

111 squ.ft./100 net = 1.11 occ. load

112

(e)Office

101

CONFFERENCE

8'-0" (Typ.Clg.Hgt)

114

SGI ROOM #1

107

KITCHEN

110

SGI ROOM #2

108

Main Utility Room

8'-0" (Typ.Clg.Hgt)

105

STORAGE

100

BUSINESS AREA

111

(e)Unisex

Toilet

112

(e) Office

113

(e) Training Room

115

(e) SGI Room

109

(e)Unisex

Toilet

104

CONSUL

103

IT Closet

102

(e) Unisex

Toilet

56 squ.ft.

102

(e)Unisex

Toilet

26 squ.ft.

103

(e)IT Closet

106

(e)Unisex

Toilet

(

e

)

S

o

C

a

l

P

h

y

s

i

c

a

l

T

h

e

r

a

p

y

a

n

d

A

c

u

p

u

n

c

t

u

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

(

e

)

D

e

n

t

a

l

C

a

r

e

(

O

c

c

u

p

a

n

c

y

g

r

o

u

p

:

B

)

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7De

mo'

d Re

flect

ed C

eilin

g Pl

anCo

nstr

uctio

n Do

cum

ents

A-1.20

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Scale: 1/8"=1'-0"

Demo'd Reflected Ceiling Plan

1

North

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

(Refer to Mech. and Elect construction documents.)

5/23

/16

5/23

/16

8/1/

16Re

visi

on1

NOTE:

Remove T-bar ceiling and lighting fixtures in this area as required.

Match and patch new T-bar ceiling to existing T-bar ceiling.

Add new lighting fixtures per approximate location,

refer to Electrical Plan (E-2.1)

NOTE:

Remove hard lid ceiling and lighting fixtures in

this area as required.

Add new T-bar ceiling and new lighting

fixtures per approximate location,

refer to Electrical Plan (E-2.1)

Note:

Contractors shall be responsible for replacing any damaged ceiling tiles.

Patch existing grid/tiles as needed.

PERMIT #:BLD16-01504

10/0

5/16

Revi

sion

2

1

11/3

/16

Revi

sion

4

Lc Lc

Desi

gned

Draw

n

Lead

Sheet

REVI

SION

SDa

teDe

scri

ptio

n

320

N. H

alst

ead

St. P

asad

ena,

CA

9110

7SU

SPEN

DED

ACOU

STIC

CEI

LIN

G TI

LE D

ETAI

LCo

nstr

uctio

n Do

cum

ents

A-1.21

CHK

-/-

Regi

onal

-/-

Dire

ctor

-/-

Oppo

rtun

ities

for L

earn

ing

Sant

a Cl

arita

Addr

ess:

276

16 N

ewha

ll Ra

nch

Rd. S

te. A

10-1

5-25

, Val

enci

a, C

A 9

1355

5/23

/16

5/23

/16

8/1/

16Re

visi

on1

PERMIT #:BLD16-01504

10/0

5/16

Revi

sion

2

3

11/3

/16

Revi

sion

4