new products - loren cook company - cook repnet … range maximum temp. rise hmd-2400 680-2400 1000f...
Post on 16-Jun-2018
233 Views
Preview:
TRANSCRIPT
1www.LorenCook.com
®2013 Introductions
QMX QMX-HP QMX-XP
HMDNew direct-fired heated make-up air unit.•Natural gas or propane fueled•ETL Listed
Model CFM Range
Maximum Temp. Rise
HMD-2400 680-2400 1000FHMD-3400 2000-3400 940FHMD-4100 3000-4100 910F
New ProductsQMXThere are now three mixed flow wheel choices, the QMX, QMX-HP, and the new QMX-XP. Each wheelisdesignedforaspecificstatic pressure range. The extended pressure XP wheel is available in sizes 150 - 600.
The QMX product line will be offered in three construction levels, depending on the application. The new “Level 1” construction is for commercial applications, where lower pressures are typical. Our current design will be designated as the “Level 2” construction. The “Level 3” is ideal for high pressure lab applications.
Level Application Maximum Static PressureQMX QMX-HP QMX-XP
1 Commercial 3” SP 4” SP -2 Industrial 5” SP 8” SP 8” SP3 Lab / Industrial - - 15” SP
Control Panel
2www.LorenCook.com
®2013 Introductions
Invertech: • Single phase 1/6 - 3/4 HP• Three phase 1 - 15 HP
New Products
Fiberglass FansCorrosion resistantfiberglassfans.
Variable Frequency DrivesOffered as a fan / motor / VFD package• Factory sized to ensure proper match to
motor and application• Factory base-line programmed to reduce
on-site startup time• Factory quality checked to ensure proper
operation• Shipped loose or mounted on the fan
Yaskawa: • Three phase 1 - 200 HP
LXU-MO, LEU-MO & LTU-MO•Additionalconfigurationofourpopularpropellerroof
ventilators with motor out (MO) of the air stream•Allows for larger motors•Easier maintenance, with motor access on the roof•UL Listing for Smoke Control available
ERV with Gas HeatNew indirect gas heat option• Natural gas or propane fueled• ETL Listed for indoor or outdoor installation• Direct spark ignition system• Horizontal or vertical discharge• 80%efficientheater• Up to 650F temp rise on all unit sizes
3www.LorenCook.com
®2013 Introductions
Gemini®
•Moreefficientmotors•Most models will be
Energy Star Rated
Product Enhancements
Energy Star Pending
SQN•Lower sound levels•AMCAcertification
will include inlet & outlet sound levels
Centrifugal Blowers•Lower sound levels •AMCAcertificationwillincludeinlet&
outlet sound •CPV, CPS, CPS-A, CPA, CPA-A,
CA, CF, CF4, CAF-DW, & CA-DWDIX.Stream FansExtended RPM & HP ranges on wall, hooded, & upblast models.
Typical Speed Limit ImprovementLow Pressure XL Medium Pressure XM
20 Testing In Progress24 Testing In Progress30 16% Faster -36 28% Faster 11% Faster42 45% Faster 15% Faster48 47% Faster 21% Faster54 Testing In Progress60 Testing In Progress
Size CFM SPInlet Sones
Current New80 500 0.5” 9.0 7.0
100 1,000 0.5” 16.0 11.1120 1,500 0.75” 20.0 13.4135 2,000 0.75” 20.0 16.3150 2,500 0.75” 18.0 12.9
Model Size CFM SPInlet LwA
Current NewCPS 100 1,000 1.0” 83 80CPS 120 2,000 1.0” 90 86CPS 150 3,000 2.0” 90 84CPS 180 4,000 2.0” 88 82
CPS-A 245 7,000 3.0” 87 79CPS-A 365 15,000 3.0” 92 81CPS-A 490 25,000 3.0” 88 82
Size CFM SPWatts
Current New126 50 0.1” 50 25128 75 0.1” 64 29146 100 0.1” 59 35148 140 0.1” 98 47166 150 0.1” 103 50168 170 0.1” 145 58242 125 0.1” 65 26
4www.LorenCook.com
®2013 Introductions
Product Certifications
QR CodesNew stickers will soon be put on all Cook fans, providing mobile app users easy access to LorenCook.com with support info and instruction manuals.
Cookware™ / Compute-A-Fan®
•Remove the “Run as Administrator” requirement•Windows 7 & 8 compatibility•Show “unit installed weight” on submittals instead of “shipping weight”• Improve auto update process to reduce download errors• Improve special freight quotes for better accuracy and reduced
response time• Improve quote process, allowing user to check status and import informationbackintojobfile
•New products with selection, saving, pricing and submittals:•QMXD / QMXHPD: Direct drive version of the QMX and QMX-HP•QMXD-VP: Direct drive QMX lab exhaust fan•LXU-MO: LXU with motor outside of airstream• HMD:Directfiredheatedmakeupairunit•FCE/FCRU/FCP: Fiberglass versions of the ACE, ACRU and CP fans•QMX-XP/QMXD-XP: Extended pressure QMX in belt and direct drive •PLC12: Plenum fan with 12 blade wheel design•CAC: New models of the CAC air circulators•CA-VP: CA Vari-Plume® lab exhaust fans
•Additional accessories and features:•Additional disconnect switches•VFD’s: Variable frequency drive accessory•Extended pedestals on CA/CF arrangement 9/10 fans•Outlet sound attenuators for QMX-VP and CA-VP lab fans•Bifurcated housing option on QMX-VP and QMXD-VP lab fans
Software Development
New Hurricane Ratings•CPS & CPV•Sizes 60 - 490 can be mounted on rails with isolators
or directly to the roof
•GI & GR •Aluminum or galvanized construction•GI sizes up to 54” x 54” throat (94” x 99” hood)•GR sizes up to 60” x 60” throat (94” x 99” hood)
REVIT New REVIT 2013 version data files&updatedimporting program
Florida Product Approval Pending
top related