mobile diagnosis of bus physics, communication and cabling

Post on 18-Oct-2021

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Mobile diagnosis of bus physics, communication and cabling ▪ PowerfulmobiletoolfordiagnosticsandtroubleshootinginPROFIBUSnetworks

 ▪ Highflexibilitythroughstand-aloneoperation(withoutPC)

 ▪ EnhanceddiagnosticfeaturesthroughPC-basedsoftware(Included)

 ▪ ProtocolanalysisofthePROFIBUSPAsegments

PROFIBUSTester5(BC-700-PB)

TestingBusCabling,BusPhysicsandBusCommunication“All-In-One” ▪ Combinationofsignaltester,storageoscilloscope, protocolanalyzer,mastersimulatorandcabletesterfunctionalityinasinglediagnosticstool ▪ Stand-alonemodeplusextendedPC-baseddiagnostics ▪ Suitedforinstallation,setupandcommissioning,documentation,acceptancetesting,networkoptimization,preventivemaintenance,troubleshootingaswellaslaboratorytests

Bustesterformobileuse,evenwithoutanotebook ▪ Battery-poweredoperationwithouttheneedfor additionalpowersupply ▪ Graphicaldisplayprovidingeasy-to-understand presentationoftestresults ▪ Comprehensivenetworktestsinstand-alonemode (nocomputerrequired):busstatus,signalquality, cabletest,stationlocalization,oscilloscope

Manyadditionalfeatures ▪ Executing,analyzingandmanagingtests(Trend,TopologyScan,MasterSimulator,Oscilloscope,FrameAnalyzer) ▪ QuickTestandUser-ControlledTestforeasynetwork statusatthepushofabutton ▪ Generationoftestreportsdescribingstatusofthe PROFIBUSinstallation ▪ Suitableforrangeofusertypes:novicetofieldbusspecialists

OptionalMeasuringAdapterforMBP(ManchesterCodedBusPowered)Physics ▪ SpecificsignalanalysissupportingMBPPhysics(feedingvoltage,signaldeviation,signalpolarity,bitratedivergence) ▪ CompleteprotocolanalysisdirectlyatPROFIBUSPAsegment

PLC(PROFIBUSMaster)

PROFIBUSDiagnosticsSuite PROFIBUSTester5

FieldDeviceFieldDeviceFieldDevice

Segment coupler

Testreport

USB

PROFIBU

SPA

Diagn

ostic

s

PROFIBU

SDP

Diagn

ostic

s

PROFIBUSSlaves

FieldDeviceFieldDevice

PROFIBUSPA

PROFIBUSDP

PROFIBUSDiagnosticFunctionalityStand-aloneOperation

PC-basedOperation

MeasurementMethodsCable test

Busstatus(measurementofimportantparameters)

Signalquality

Quicktest(networkstatus) 1

User-controlledtest(networkstatus)

Trend(long-termrecordingofqualityindexanderrors) 1

Topology(sequenceofstationsanddistances)

Oszilloscope

Framerecordinganddisplaying

MasterSimulator

CableTestCable Length

Checkofbustermination

Detectionwirebreak,shieldbreak,shortcircuit

Reportofcabletestresults

BusandNetworkStatusIdlevoltage/baudrate,pluggedtostaton…

Numberofmasters/slaves/commissionedbutnotactive

Networkevaluation(protocol,signalquality,errors)

Networkstatistics(repetitions,diagnosticmessages,TTR)

Stationscan(LiveList)includingchanges

Stationevaluation(protocol,signalquality)

Stationstatistics(repetitions,diagnosticmessages,qualityindex)

Comprehensiveevaluationofnetworkhealth

ComprehensiveprotocolanalysisincludingLiveListandstatistics

GSD-baseddecodingofdiagnosticmessages

SignalQualityQualityIndexasbargraph

Signal-to-noiseratioandrisetimes

TrendingLong-termrecordingofqualityindexanderrors 1

TopologyActiveTDRmeasurementwithgraphicalrepresentation

Passivestationlocalization(non-interacting)

OszilloscopeSignalrepresentationA–Bupto384MHzscanrate

SignalrepresentationA-GNDundB-GNDupto192MHzscanrate

Zoom/shift

Trigger:notrigger/level/address/errorframes

Savingoscilloscoperecordings

FrameRecordingInstantrecording(ringbuffer)

Long-termrecording(tofiles)

Frame-controlledrecording(trigger)

Recordingfilteranddisplayfilter

Comprehensiveframedecoding

1Testcanbeconductedandstoredinstand-aloneoperation,evaluationoftestresultsinPCmodeonly

YourlocalSoftingcontact:

Technicalchangesreserved©SoftingIndustrialAutomationGmbH,BC-700-PB_D_EN_210311_204,March2021

http://industrial.softing.com

PROFIBUSTester5(BC-700-PB)TechnicalDataDIAGNOSTICSFUNCTIONALITY

ProtocolandFrameAnalysisSignalAnalysis:...viaEIA-485

...viaMBP (requiresoptionaladapter)

OscilloscopeDisplay(N/AforMBP)

TopologyScan(N/AforMBP)CableTest(N/AforMBP)

PROFIBUSDP-V0andDP-V1,automaticbaudratedetectionintherangeof9.6kbit/s…12Mbit/sPROFIBUSDP-V0,DP-V1,FMSandMPISignalqualityindex:0…5.000,determinedfromsignallevelaswellassignal/noiseratioandrisetime;signalsamplingwith8/16samplesperbitFieldbusfeedingvoltage:0V...35Vat0.1Vresolution,signallevel:100mV...1.200mVat10mVresolution,signalpolarity, bitratedivergence:±1.2%at0,01%resolution,signalsamplingwith128samplesperbitTestrange:±5Vat10mVresolution(differential),esolution(AorBtoDGND);samplingrate:upto384 Msamples/s;sampledpoints:2,400(signaldetails),8,192(oscilloscopeanalysis)Active,maximumdistance:230m,accuracy:±2mActive,supportedcablesegmentlength:5m…1,500m,accuracy:5%

Operation Viagraphicalcolourdisplay,fourfunctionkeysandscrollwheelincludingcentralpush-buttonorviaPC/notebookDisplaylocalization:EN,DE,ES,FR,IT,PL,PTT

InternalMemoryCapacity 3user-definablenetworkdirectories(segmentandtestlocation)forstoringquicktests,trendlogsandcabletestresultsTrendlogging:max.99hours

Trigger IN:L=0V..0.8V;H=2.4V..24V;pulse>10μs,activehighOUT:approximately5V,activelow(connectiontostorageoscilloscope)PCOpreatingSoftware PROFIBUSDiagnosticsSuite,seeseparatedatasheetfordetailsCONNECTORS

EIA-485(PROFIBUSDP)MBP(PROFIBUSPA)

USB

PROFIBUSD-subconnector,9pins,powersupplyforexternalbusterminationConnector,3pins,forscrewterminalsatoptinalmeasuringadapter,measuringcablesetincluding3probes (adapterforMBPmeasurementisattachedtoD-subconnector)V2.0,highspeed480Mbit/s,galvanicallyisolated

Dimensions(HxWxD) 35mmx220mmx110mmPowerSupply Built-inthree-celllithium-ionbattery.Usedbatterytype:PA-L27.K02(UN38.3certified).

Supporting11.1VDCorexternalACadapter100VAC...240VAC,50/60Hz(galvanicallyisolated).Therechargeablebatteryhasaruntimeofupto5hours(runtimedependsontheperformedtestfunctionalityandrateofwearoftherechargeablebattery),batteryischargedviaexternalACadapter.

Operating/StorageTemperature Operatingtemperature:0°C...50°C,storagetemperature:-20°C...70°CRelativeHumidity Airhumidity:10%...90%withoutcondensationWeight Testtool,nocable:approximately0.75kg;completecarryingcase:approximately4.2kgConformity CE,FCC,VCCI

ScopeofDeliveryHardware PROFIBUSTester5(BC-700-PB),powersupplyunit100VAC...240VAC,50/60HzwithconnectingcablesforEuropeandUSA,

adaptorcables,carryingcaseSoftware PROFIBUSDiagnosticsSuite(PCsoftwareforWindowsonCD-ROM)Documentation Devicemanual,“GettingStarted“manual

OrderNumberDDA-NN-006014 PROFIBUSTester5(BC-700-PB)

AdditionalProductsandLicensesDDL-NL-006010 PA-adapter+cablesetACA-NN-006033 D-SubtoM12adaptersetwithT-pieceandM12busterminationforPROFIBUSDPDDA-ZZ-004010 DigitalFieldbusLeakageCurrentClampforLocatingEMCProblems,40..1000Hz,MIN/MAX,DataHold,MeasuringCables,suppliedina

HandyCase(fitsinEmptyCompartmentofCarryingCase)ACL-NN-006037 D-SubServiceInterfacewithActiveBusTerminationand90°AngledConnectorforPROFIBUSDPACA-NN-006034 M12ServiceInterfaceforPROFIBUSDP,ComprisingM12T-Piece,EndCapandM12ConnectionCable(1m)ACA-NN-006031 EIA-485D-SubadaptercablefortestingoperationalnetworkswithreducedinfluenceonsegmentoperationTRA-PB-TS Training:PROFIBUSTroubleshootingwithexamtoCertifiedPROFIBUSInstaller

top related