mobile diagnosis of bus physics, communication and cabling
TRANSCRIPT
Mobile diagnosis of bus physics, communication and cabling ▪ PowerfulmobiletoolfordiagnosticsandtroubleshootinginPROFIBUSnetworks
▪ Highflexibilitythroughstand-aloneoperation(withoutPC)
▪ EnhanceddiagnosticfeaturesthroughPC-basedsoftware(Included)
▪ ProtocolanalysisofthePROFIBUSPAsegments
PROFIBUSTester5(BC-700-PB)
TestingBusCabling,BusPhysicsandBusCommunication“All-In-One” ▪ Combinationofsignaltester,storageoscilloscope, protocolanalyzer,mastersimulatorandcabletesterfunctionalityinasinglediagnosticstool ▪ Stand-alonemodeplusextendedPC-baseddiagnostics ▪ Suitedforinstallation,setupandcommissioning,documentation,acceptancetesting,networkoptimization,preventivemaintenance,troubleshootingaswellaslaboratorytests
Bustesterformobileuse,evenwithoutanotebook ▪ Battery-poweredoperationwithouttheneedfor additionalpowersupply ▪ Graphicaldisplayprovidingeasy-to-understand presentationoftestresults ▪ Comprehensivenetworktestsinstand-alonemode (nocomputerrequired):busstatus,signalquality, cabletest,stationlocalization,oscilloscope
Manyadditionalfeatures ▪ Executing,analyzingandmanagingtests(Trend,TopologyScan,MasterSimulator,Oscilloscope,FrameAnalyzer) ▪ QuickTestandUser-ControlledTestforeasynetwork statusatthepushofabutton ▪ Generationoftestreportsdescribingstatusofthe PROFIBUSinstallation ▪ Suitableforrangeofusertypes:novicetofieldbusspecialists
OptionalMeasuringAdapterforMBP(ManchesterCodedBusPowered)Physics ▪ SpecificsignalanalysissupportingMBPPhysics(feedingvoltage,signaldeviation,signalpolarity,bitratedivergence) ▪ CompleteprotocolanalysisdirectlyatPROFIBUSPAsegment
PLC(PROFIBUSMaster)
PROFIBUSDiagnosticsSuite PROFIBUSTester5
FieldDeviceFieldDeviceFieldDevice
Segment coupler
Testreport
USB
PROFIBU
SPA
Diagn
ostic
s
PROFIBU
SDP
Diagn
ostic
s
PROFIBUSSlaves
FieldDeviceFieldDevice
PROFIBUSPA
PROFIBUSDP
PROFIBUSDiagnosticFunctionalityStand-aloneOperation
PC-basedOperation
MeasurementMethodsCable test
Busstatus(measurementofimportantparameters)
Signalquality
Quicktest(networkstatus) 1
User-controlledtest(networkstatus)
Trend(long-termrecordingofqualityindexanderrors) 1
Topology(sequenceofstationsanddistances)
Oszilloscope
Framerecordinganddisplaying
MasterSimulator
CableTestCable Length
Checkofbustermination
Detectionwirebreak,shieldbreak,shortcircuit
Reportofcabletestresults
BusandNetworkStatusIdlevoltage/baudrate,pluggedtostaton…
Numberofmasters/slaves/commissionedbutnotactive
Networkevaluation(protocol,signalquality,errors)
Networkstatistics(repetitions,diagnosticmessages,TTR)
Stationscan(LiveList)includingchanges
Stationevaluation(protocol,signalquality)
Stationstatistics(repetitions,diagnosticmessages,qualityindex)
Comprehensiveevaluationofnetworkhealth
ComprehensiveprotocolanalysisincludingLiveListandstatistics
GSD-baseddecodingofdiagnosticmessages
SignalQualityQualityIndexasbargraph
Signal-to-noiseratioandrisetimes
TrendingLong-termrecordingofqualityindexanderrors 1
TopologyActiveTDRmeasurementwithgraphicalrepresentation
Passivestationlocalization(non-interacting)
OszilloscopeSignalrepresentationA–Bupto384MHzscanrate
SignalrepresentationA-GNDundB-GNDupto192MHzscanrate
Zoom/shift
Trigger:notrigger/level/address/errorframes
Savingoscilloscoperecordings
FrameRecordingInstantrecording(ringbuffer)
Long-termrecording(tofiles)
Frame-controlledrecording(trigger)
Recordingfilteranddisplayfilter
Comprehensiveframedecoding
1Testcanbeconductedandstoredinstand-aloneoperation,evaluationoftestresultsinPCmodeonly
YourlocalSoftingcontact:
Technicalchangesreserved©SoftingIndustrialAutomationGmbH,BC-700-PB_D_EN_210311_204,March2021
http://industrial.softing.com
PROFIBUSTester5(BC-700-PB)TechnicalDataDIAGNOSTICSFUNCTIONALITY
ProtocolandFrameAnalysisSignalAnalysis:...viaEIA-485
...viaMBP (requiresoptionaladapter)
OscilloscopeDisplay(N/AforMBP)
TopologyScan(N/AforMBP)CableTest(N/AforMBP)
PROFIBUSDP-V0andDP-V1,automaticbaudratedetectionintherangeof9.6kbit/s…12Mbit/sPROFIBUSDP-V0,DP-V1,FMSandMPISignalqualityindex:0…5.000,determinedfromsignallevelaswellassignal/noiseratioandrisetime;signalsamplingwith8/16samplesperbitFieldbusfeedingvoltage:0V...35Vat0.1Vresolution,signallevel:100mV...1.200mVat10mVresolution,signalpolarity, bitratedivergence:±1.2%at0,01%resolution,signalsamplingwith128samplesperbitTestrange:±5Vat10mVresolution(differential),esolution(AorBtoDGND);samplingrate:upto384 Msamples/s;sampledpoints:2,400(signaldetails),8,192(oscilloscopeanalysis)Active,maximumdistance:230m,accuracy:±2mActive,supportedcablesegmentlength:5m…1,500m,accuracy:5%
Operation Viagraphicalcolourdisplay,fourfunctionkeysandscrollwheelincludingcentralpush-buttonorviaPC/notebookDisplaylocalization:EN,DE,ES,FR,IT,PL,PTT
InternalMemoryCapacity 3user-definablenetworkdirectories(segmentandtestlocation)forstoringquicktests,trendlogsandcabletestresultsTrendlogging:max.99hours
Trigger IN:L=0V..0.8V;H=2.4V..24V;pulse>10μs,activehighOUT:approximately5V,activelow(connectiontostorageoscilloscope)PCOpreatingSoftware PROFIBUSDiagnosticsSuite,seeseparatedatasheetfordetailsCONNECTORS
EIA-485(PROFIBUSDP)MBP(PROFIBUSPA)
USB
PROFIBUSD-subconnector,9pins,powersupplyforexternalbusterminationConnector,3pins,forscrewterminalsatoptinalmeasuringadapter,measuringcablesetincluding3probes (adapterforMBPmeasurementisattachedtoD-subconnector)V2.0,highspeed480Mbit/s,galvanicallyisolated
Dimensions(HxWxD) 35mmx220mmx110mmPowerSupply Built-inthree-celllithium-ionbattery.Usedbatterytype:PA-L27.K02(UN38.3certified).
Supporting11.1VDCorexternalACadapter100VAC...240VAC,50/60Hz(galvanicallyisolated).Therechargeablebatteryhasaruntimeofupto5hours(runtimedependsontheperformedtestfunctionalityandrateofwearoftherechargeablebattery),batteryischargedviaexternalACadapter.
Operating/StorageTemperature Operatingtemperature:0°C...50°C,storagetemperature:-20°C...70°CRelativeHumidity Airhumidity:10%...90%withoutcondensationWeight Testtool,nocable:approximately0.75kg;completecarryingcase:approximately4.2kgConformity CE,FCC,VCCI
ScopeofDeliveryHardware PROFIBUSTester5(BC-700-PB),powersupplyunit100VAC...240VAC,50/60HzwithconnectingcablesforEuropeandUSA,
adaptorcables,carryingcaseSoftware PROFIBUSDiagnosticsSuite(PCsoftwareforWindowsonCD-ROM)Documentation Devicemanual,“GettingStarted“manual
OrderNumberDDA-NN-006014 PROFIBUSTester5(BC-700-PB)
AdditionalProductsandLicensesDDL-NL-006010 PA-adapter+cablesetACA-NN-006033 D-SubtoM12adaptersetwithT-pieceandM12busterminationforPROFIBUSDPDDA-ZZ-004010 DigitalFieldbusLeakageCurrentClampforLocatingEMCProblems,40..1000Hz,MIN/MAX,DataHold,MeasuringCables,suppliedina
HandyCase(fitsinEmptyCompartmentofCarryingCase)ACL-NN-006037 D-SubServiceInterfacewithActiveBusTerminationand90°AngledConnectorforPROFIBUSDPACA-NN-006034 M12ServiceInterfaceforPROFIBUSDP,ComprisingM12T-Piece,EndCapandM12ConnectionCable(1m)ACA-NN-006031 EIA-485D-SubadaptercablefortestingoperationalnetworkswithreducedinfluenceonsegmentoperationTRA-PB-TS Training:PROFIBUSTroubleshootingwithexamtoCertifiedPROFIBUSInstaller