metashield l fire shutters - smoke control · metashield -l laterally operating fire shutters smoke...

Post on 01-Aug-2020

3 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

PIONEERS IN LIFE SAFETY SOLUTIONS

Metashield - L laterally operating fire shutters

Smoke Control’s

Full Life Cycle Service ensures that at any

stage of the project – from design through

to commissioning – the only company

responsible is

Smoke Control.

1300 665 471

www.smokecontrol.com.au

2 hour protection from fire January 2014

Metashield fire shutters are an ideal

solution for providing fire

compartmentation and security.

Available in galvanised, painted and

stainless steel finishes the system is

suited to extra large openings.

The system has a vertically standing

barrel with head track which

operates sideways from the wall.

This configuration is ideal for large

opening with limited head room.

So why the Metashield L fire

shutter ?

Metashield fire shutters incorporate

patented design features that allow

continuous spans of up to 14m wide.

X 7m drop.

The system can also curve and

weave around objects.

Approvals cover unlimited lengths,

but require design input by Smoke

Control.

100% QUALITY

The largest fire shutter

system available;

Fire tested up to 2

hours (-/120/-) in

accordance with

AS1530.4 and

AS1905.2

High quality fittings

that will last the life

of the product

Operates sideways

much like a sliding

fire door but with

much less side wall

space required when

in the open position

Available in

galvanised, painted

or stainless steel

finish

Horizontal and

laterally operated fire

shutter systems also

available

Maintenance services

available, please

contact our

maintenance

department.

www.smokecontrol.com.au 1300 665 471 www.smokecontrol.com.au info@smokecontrol.com.au 1300 665 471

Smoke Control offers obligation free technical support

throughout your design and documentation stage. We

are also happy to provide obligation free pricing so

that you can accurately prepare your budgets

We have also prepared a complete kit for your

documentation requirements. Simply down load from

our web site a complete set of specifications and

drawings. If you would like our drawings in DWG

format, simply give our technical department a call or

email your request.

We will endeavour to respond to your emails the same

day !

100% Customer Service

TECHNICAL SUPPORT by qualified engineers and draftspeople

info@smokecontrol.com.au

Click these links, they

will take you to our website

MASTER

SPECIFICATIONS

Download

DESIGN DETAILS

Download

www.smokecontrol.com.au info@smokecontrol.com.au 1300 665 471

100% Flexibility

Full scale fire tested and approved to AS1530.4 & AS1905.2 for 2 and 4 hour fire ratings. Also available

with a -/120/30 fire resistance level when sprinklers are installed in accordance with our specifications.

Built for distance, the Metashield long span vertical fire shutter is tough and reliable, resisting pressures

in excess of 100Pa when fully deployed.