metashield l fire shutters - smoke control · metashield -l laterally operating fire shutters smoke...
TRANSCRIPT
PIONEERS IN LIFE SAFETY SOLUTIONS
Metashield - L laterally operating fire shutters
Smoke Control’s
Full Life Cycle Service ensures that at any
stage of the project – from design through
to commissioning – the only company
responsible is
Smoke Control.
1300 665 471
www.smokecontrol.com.au
2 hour protection from fire January 2014
Metashield fire shutters are an ideal
solution for providing fire
compartmentation and security.
Available in galvanised, painted and
stainless steel finishes the system is
suited to extra large openings.
The system has a vertically standing
barrel with head track which
operates sideways from the wall.
This configuration is ideal for large
opening with limited head room.
So why the Metashield L fire
shutter ?
Metashield fire shutters incorporate
patented design features that allow
continuous spans of up to 14m wide.
X 7m drop.
The system can also curve and
weave around objects.
Approvals cover unlimited lengths,
but require design input by Smoke
Control.
100% QUALITY
The largest fire shutter
system available;
Fire tested up to 2
hours (-/120/-) in
accordance with
AS1530.4 and
AS1905.2
High quality fittings
that will last the life
of the product
Operates sideways
much like a sliding
fire door but with
much less side wall
space required when
in the open position
Available in
galvanised, painted
or stainless steel
finish
Horizontal and
laterally operated fire
shutter systems also
available
Maintenance services
available, please
contact our
maintenance
department.
www.smokecontrol.com.au 1300 665 471 www.smokecontrol.com.au [email protected] 1300 665 471
Smoke Control offers obligation free technical support
throughout your design and documentation stage. We
are also happy to provide obligation free pricing so
that you can accurately prepare your budgets
We have also prepared a complete kit for your
documentation requirements. Simply down load from
our web site a complete set of specifications and
drawings. If you would like our drawings in DWG
format, simply give our technical department a call or
email your request.
We will endeavour to respond to your emails the same
day !
100% Customer Service
TECHNICAL SUPPORT by qualified engineers and draftspeople
Click these links, they
will take you to our website
MASTER
SPECIFICATIONS
Download
DESIGN DETAILS
Download
www.smokecontrol.com.au [email protected] 1300 665 471
100% Flexibility
Full scale fire tested and approved to AS1530.4 & AS1905.2 for 2 and 4 hour fire ratings. Also available
with a -/120/30 fire resistance level when sprinklers are installed in accordance with our specifications.
Built for distance, the Metashield long span vertical fire shutter is tough and reliable, resisting pressures
in excess of 100Pa when fully deployed.